What sets an integrated bridge system apart

A conventional bridge has separate, independently wired instruments, a radar unit, an ECDIS terminal, an autopilot control head, a GPS repeater, each with its own display and its own failure mode. An Integrated Bridge System (IBS), sometimes certified to the stricter Integrated Navigation System (INS) performance standard, ties these functions together over a shared data network so that any workstation on the bridge can display any function: conning, radar overlay, chart, alarm status. The point is not just convenience; IMO performance standards (MSC.252(83) for INS) require that the integration does not create a single point of failure that takes down navigation entirely, so a properly built system still lets the watch officer fall back to independent stand-alone operation of each sensor if the integration layer itself fails.

Bridge integration system layout
Block diagram of a bridge integration system showing the radar, ECDIS, conning and autopilot workstations linked by a shared data bus to the alarm management function and the navigation sensor inputs, so any console can access all functions.

Main components

Multifunction workstations

Identical or near-identical consoles that can each be configured to show radar, ECDIS, conning or alarm screens, reducing the number of unique spare parts on board compared with dedicated single-purpose units.

Sensor inputs

GPS, gyrocompass, speed log, echo sounder, AIS and wind sensors feed the network individually, with the IBS responsible for distributing and time-stamping their data consistently across every display.

Read the full guide

Data network and switching

A redundant network backbone, often dual-redundant Ethernet, connects sensors to workstations; the switching architecture is what INS performance standards scrutinise most closely for single points of failure.

Alarm management system

A centralised alert handler collects and prioritises alarms from every connected sensor and subsystem so the watch officer sees one coherent alarm picture rather than competing individual alarms.

Conning display

A dedicated screen summarising heading, speed, rate of turn, rudder angle and engine data for close-quarters manoeuvring, usually positioned centrally regardless of which workstation the officer is otherwise using.

Selection and sizing

  • Number of workstations against bridge layout and the number of watch officers expected to use them simultaneously in restricted waters.
  • Whether INS certification to IMO MSC.252(83) is required by the flag state or intended trade, versus a lower-tier IBS that integrates functions without full INS redundancy.
  • Compatibility with existing sensors if the project is a retrofit rather than a newbuild, since sensor age and interface protocol often force a wider replacement than planned.
  • Software update and cyber security support arrangement, since a networked bridge carries the same patching obligations as any other networked system.

Regulations and class

SOLAS Chapter V sets carriage requirements for the individual navigation functions an IBS integrates. IMO performance standard MSC.252(83) applies specifically to Integrated Navigation Systems and defines the redundancy and independent-operation requirements referenced above. Classification societies survey the bridge equipment under their navigation and communication equipment rules, and IACS Unified Requirements address cyber resilience for networked bridge systems on newer tonnage. Type approval of the specific IBS/INS configuration, not just the individual sensors, is generally required before it can be fitted.

Typical faults

FaultCauseConsequence
Workstation freeze or blank screenSoftware fault or network switch failureLoss of one display; officer must switch to another workstation or fall back to stand-alone mode
Sensor data mismatch between displaysTime synchronisation drift across the networkConflicting position or heading readouts, watch officer confusion
Alarm floodAlarm management thresholds not tuned to the vessel's actual sensor setOfficer desensitised to genuine alarms during heavy weather or port entry
Failure to revert to stand-alone modeFallback logic not tested since commissioningFull navigation blackout if the integration layer fails

What to look for in a supplier

  • A demonstrated, tested procedure for falling back to stand-alone sensor operation, not just a claim that it exists.
  • Type approval certificates matching the exact configuration being purchased, not a generic product line certificate.
  • Training support for bridge teams, since an integrated system changes watchkeeping habits more than a single-instrument replacement does.
  • A defined cyber security update path, given the networked architecture.

Test the fallback-to-stand-alone procedure on every workstation during a quiet passage, not just once at commissioning; officers who have never actually done it under pressure lose time in the one moment the integration layer fails and they need it most.

Models

Models in this type.

The best-documented model of each manufacturer first, then the next — 2 of 2 models in Bridge Integration System (IBS/INS). Every row links to full specifications, documents and service notes.

Showing only SAILOR / Thrane & Thrane. Show all manufacturers
2 models
Would you like to know more?

One request. A person reads it and replies by e-mail.

Tell us the manufacturer, the model and what you need — a part, a service call, a second opinion. A person reads every request and replies by e-mail.

No details at hand? A photo of the rating plate or the part is enough — simply attach it to the request.

Frequently asked

Three things people ask first.

Is Bridge Integration System (IBS/INS) data free?

Yes. Every model page, every guide and every datasheet for this type is readable without an account. An account adds saved searches and requests, nothing is taken away.

My model is missing — what now?

Send us the nameplate. We identify it by hand, add it to the library, and if you need a part or a service, the request is already on our desk.

Can you source a Bridge Integration System (IBS/INS) part?

Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.