OceanSphereEnginesPartsWorkServiceNetworkAdditiveFree accountLog inDEENPL
OceanSphereENGINES
Library Engine Room Boilers Boiler
Boilers

Boiler

A marine boiler raises steam either by burning fuel oil directly in an oil-fired unit or by recovering exhaust gas heat from the main engine in an economiser, and most vessels carry both types working into a common steam system.

80models 21manufacturers
Models

Models in this type.

The 80 models with the most complete data of 80 in Boiler. Every row links to full specifications, documents and service notes.

Alfa Laval S.p.A.Aalborg AV Alfa Laval S.p.A.Aalborg D Alfa Laval S.p.A.Aalborg ESB Alfa Laval S.p.A.Aalborg MC Alfa Laval S.p.A.Aalborg MD Alfa Laval S.p.A.Aalborg MP Alfa Laval S.p.A.Aalborg MX Alfa Laval S.p.A.Aalborg-EH-100 Alfa Laval S.p.A.Aalborg-EH-1000 Alfa Laval S.p.A.Aalborg-EH-2000 Alfa Laval S.p.A.Aalborg-EH-250 Alfa Laval S.p.A.Aalborg-EH-3000 Alfa Laval S.p.A.Aalborg-EH-500 Alfa Laval S.p.A.Aalborg-EH-5000 Alfa Laval S.p.A.Aalborg-ESB-1250 Alfa Laval S.p.A.Aalborg-ESB-160 Alfa Laval S.p.A.Aalborg-ESB-2500 Alfa Laval S.p.A.Aalborg-ESB-320 Alfa Laval S.p.A.Aalborg-ESB-630 Alfa Laval S.p.A.Aalborg-OC-TCi-1.5 Alfa Laval S.p.A.Aalborg-OC-TCi-1.5-16bar Alfa Laval S.p.A.Aalborg-OC-TCi-1.5-20bar Alfa Laval S.p.A.Aalborg-OC-TCi-1.5-7bar Alfa Laval S.p.A.Aalborg-OC-TCi-12 Alfa Laval S.p.A.Aalborg-OC-TCi-12-16bar Alfa Laval S.p.A.Aalborg-OC-TCi-12-20bar Alfa Laval S.p.A.Aalborg-OC-TCi-12-7bar Alfa Laval S.p.A.Aalborg-OC-TCi-2.5 Alfa Laval S.p.A.Aalborg-OC-TCi-2.5-16bar Alfa Laval S.p.A.Aalborg-OC-TCi-2.5-20bar Alfa Laval S.p.A.Aalborg-OC-TCi-2.5-7bar Alfa Laval S.p.A.Aalborg-OC-TCi-20 Alfa Laval S.p.A.Aalborg-OC-TCi-20-16bar Alfa Laval S.p.A.Aalborg-OC-TCi-20-20bar Alfa Laval S.p.A.Aalborg-OC-TCi-20-7bar Alfa Laval S.p.A.Aalborg-OC-TCi-4.0 Alfa Laval S.p.A.Aalborg-OC-TCi-4.0-16bar Alfa Laval S.p.A.Aalborg-OC-TCi-4.0-20bar Alfa Laval S.p.A.Aalborg-OC-TCi-4.0-7bar Alfa Laval S.p.A.Aalborg-OC-TCi-6.0 Alfa Laval S.p.A.Aalborg-OC-TCi-6.0-16bar Alfa Laval S.p.A.Aalborg-OC-TCi-6.0-20bar Alfa Laval S.p.A.Aalborg-OC-TCi-6.0-7bar Alfa Laval S.p.A.Aalborg-OC-TCi-9.0 Alfa Laval S.p.A.Aalborg-OC-TCi-9.0-16bar Alfa Laval S.p.A.Aalborg-OC-TCi-9.0-20bar Alfa Laval S.p.A.Aalborg-OC-TCi-9.0-7bar nmtmembersinusjevielectricheatingSWH EL 150 nmtmembersinusjevielectricheatingSWH EL 230 nmtmembersinusjevielectricheatingSWH EL 300 nmtmembersinusjevielectricheatingSWH ES 160 nmtmembersinusjevielectricheatingSWH ES 210 nmtmembersinusjevielectricheatingSWH ES 300 nmtmembersinusjevielectricheatingSWH ES 500 Alfa Laval Aalborg (Denmark)AQ Series (Exhaust Gas Economiser) 500-30,000 kW thermal recovery Alfa Laval Aalborg (Denmark)Mission Series (Composite Boiler) 200-5,000 kg/h steam Alfa Laval Aalborg (Denmark)OL Series (Oil-Fired Auxiliary Boiler) 500-25,000 kg/h steam NMT member – Sinus Jevi Electric Heating BVHWB 100 NMT member – Sinus Jevi Electric Heating BVHWB 35 NMT member – Sinus Jevi Electric Heating BVHWB 55 Kangrim Heavy Industries (South Korea)KEG Series (Exhaust Gas Economiser) 500-25,000 kW thermal recovery Kangrim Heavy Industries (South Korea)KEV Series (Oil-Fired Auxiliary Boiler) 500-20,000 kg/h steam QuickBK2 160/200 L QuickNAUTIC BOILER BX 16 globalOEVC3-120 globalOEVC90-19 Alfa Laval Aalborg A/SAalborg-OL Torque per Hersteller-Datenblatt Babcock Wanson (France/UK)Marine Fire Tube Boiler 300-5,000 kg/h steam Clayton Industries (USA)Marine Steam Generator 100-2,000 kg/h steam Cochran (UK)Marine Fire Tube Boiler 200-5,000 kg/h steam Hurst Boiler (USA)Marine Fire Tube Series 100-2,000 kg/h steam Miura (Japan)Marine Once-Through Boiler 100-3,000 kg/h steam Parat Halvorsen (Norway)Marine Steam / Thermal Oil Boiler 200-5,000 kg/h steam or 200-5,000 kW thermal Saacke (Germany)SKVG / FMB Series (Marine Burner + Boiler) 200-15,000 kg/h steam Shanghai Boiler Works (China)SZL/DZL Marine Boiler Series 500-15,000 kg/h steam Sunflame (Japan)Marine Burner Systems Steam capacity per Hersteller-Datenblatt Sunrod / Wärtsilä (Finland)Marine Thermal Oil Heater 200-5,000 kW thermal Unilux (Netherlands)Marine Composite Boiler 200-2,000 kg/h steam Volcano (Japan)Marine Fire Tube / Water Tube Boiler 200-10,000 kg/h steam Mitsubishi Heavy IndustriesKU30GSI
By manufacturer

Manufacturers.

All 21 manufacturers with models of Boiler. Every name opens a search across the full library.

Related types

Also in Boilers.

The other equipment types in this category.

Auxiliary BoilerAuxiliary Boiler (Oil-Fired)Auxiliary Oil-Fired BoilerComposite BoilerComposite BoilerExhaust Gas BoilerExhaust Gas EconomizerExhaust Gas EconomizerInert Gas Generator (Tanker)Marine BurnerSteam BoilerThermal Oil HeaterThermal Oil Heater (for tankers)
Knowledge

What to check on a Boiler.

Marine boilers split into two working principles that are often confused as one system. An oil-fired auxiliary boiler burns fuel directly to raise steam whenever the ship needs it, in port or at sea, independent of the main engine. An exhaust gas economiser instead recovers waste heat from the main engine's exhaust, producing steam for free while under way but nothing when the engine is stopped or running at low load. Most cargo ships run both into a shared steam drum or system, with the oil-fired unit picking up load…

What Sets This Category Apart

Marine boilers split into two working principles that are often confused as one system. An oil-fired auxiliary boiler burns fuel directly to raise steam whenever the ship needs it, in port or at sea, independent of the main engine. An exhaust gas economiser instead recovers waste heat from the main engine's exhaust, producing steam for free while under way but nothing when the engine is stopped or running at low load. Most cargo ships run both into a shared steam drum or system, with the oil-fired unit picking up load in port and the economiser doing the bulk of the work at sea.

Boiler with oil-fired furnace and exhaust gas economiser
Composite marine boiler where an oil-fired furnace and an exhaust gas economiser both raise steam into a common steam drum fitted with a safety valve and water level gauge.

Main Components

Furnace and Burner (Oil-Fired Type)

The combustion chamber and its burner assembly, with automatic flame safeguard controls that shut fuel supply on flame failure, low water level or high pressure.

Gas-Side Heating Surface (Economiser Type)

Finned tube banks arranged in the exhaust uptake, sized to extract heat without an excessive back-pressure penalty on the main engine.

Steam Drum

Separates steam from water and provides the reserve volume that absorbs load swings without the water level swinging wildly.

Water Level Controls and Alarms

Independent high and low level alarms plus a low-low level shutdown, since a boiler run dry, even briefly, can warp or rupture tubes.

Safety Valves

Spring-loaded valves set to lift before design pressure is exceeded, tested and sealed at survey.

Selection and Sizing

  • Steam capacity matched to the largest simultaneous demand: fuel heating, accommodation heating, tank cleaning or cargo heating on tankers
  • Working pressure and superheat requirement, if any, of the connected consumers
  • Economiser gas-side pressure drop kept within the main engine maker's allowable back-pressure limit
  • Soot blowing arrangement for the economiser, since fouled fins lose effectiveness quickly on heavy fuel

Regulations and Class

Boilers are subject to periodic internal and external survey under class rules, with safety valve testing, water level alarm testing and, for older or higher-pressure units, thickness gauging of tubes and drums. SOLAS Ch. II-2 fire safety provisions apply to the boiler space itself, and MARPOL Annex VI governs the fuel burned in an oil-fired unit the same as it does the main engine.

Typical Faults

FaultConsequence
Economiser fins fouled with soot on heavy fuel operationFalling steam output and rising exhaust back-pressure on the main engine
Burner flame safeguard bypassed or defeatedUnburned fuel accumulates and reignites as a furnace explosion
Water level gauge glass blocked or misreadLow water level missed, risking tube overheating and failure
Safety valve seized from infrequent liftingOverpressure protection lost, a survey failure and genuine hazard

What to Look for in a Supplier

  • Design pressure and steam output backed by class-approved calculation, not a catalog estimate
  • Economiser back-pressure figures cross-checked against the specific main engine model
  • Soot blower and cleaning access designed into the unit, not added as an afterthought

Never trust a single water level indication - cross-check the gauge glass against the remote level alarm before every watch handover, because a boiler dried out by a stuck gauge glass fails suddenly and expensively.

Search by manufacturer AFRISOWISKASwagelokAlfa Laval S.p.A.MAN Energy SolutionsSEIMIWärtsiläEndress+HauserABB MarineAlfa LavalMacGregorNovenco MarineCarrier MarineSiemens MarineHeinen & Hopman
Would you like to know more?

One request. A person answers within 24 hours on working days.

Tell us the manufacturer, the model and what you need — a part, a service call, a second opinion. Our desk asks the right suppliers from a network of over 114,000 companies and comes back with a quote or a sourcing plan, not a search page.

Frequently asked

Three things people ask first.

Is Boiler data free?

Yes. Every model page, every guide and every datasheet for this type is readable without an account. An account adds saved searches and requests, nothing is taken away.

My model is missing — what now?

Send us the nameplate. We identify it by hand, add it to the library, and if you need a part or a service, the request is already on our desk.

Can you source a Boiler part?

Yes. Tell us the manufacturer, the model and what you need — our desk asks the right suppliers from a network of over 114,000 companies and comes back with a quote or a sourcing plan.