The Alfa Laval S.p.A. Aalborg D is a fired marine boiler from the Aalborg D family. The Aalborg D is a D-type water-tube boiler intended to produce steam or hot water from an approved oil or gas firing system and is particularly associated with installations requiring substantial service-steam capacity. Its water-tube arrangement uses drums and generating tubes around the furnace so heat from combustion is transferred to circulating boiler water. On tankers and other steam-intensive vessels it can support cargo heating, tank cleaning, fuel heating and general ship services depending on the installed plant design. Compared with smaller auxiliary boilers, survey attention extends across burner performance, furnace condition, water circulation, tube integrity, refractory or membrane-wall condition and combustion safeguards. The exact firing equipment, fuel capability, capacity and approved working pressure of the installed Aalborg D must be taken from its nameplate and manufacturer documentation; refer to the manufacturer documentation for the exact figure.

Components & Design

Component data being added…

Technical Data

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Burner nozzle, atomization, ignition or flame-scanner faults cause poor combustion, smoke, flame failure or repeated burner trips
Fireside soot deposits reduce heat transfer and can raise exhaust temperature or contribute to local overheating
Poor boiler-water treatment causes scale, corrosion or deposits inside tubes and may lead to overheating or tube failure
Tube leakage or pressure-part cracking produces abnormal make-up water demand, steam leakage or contamination in the furnace/gas path
Faulty level controls, feedwater regulation, fuel valves or combustion interlocks cause unstable operation or safety shutdowns

Service & Maintenance

Inspect furnace, accessible membrane walls or tubes, gas passages, burner equipment and refractory areas for deposits, cracking, leakage and overheating. Check feedwater and boiler-water records and verify gauge glasses, level transmitters, low-water trips, flame safeguards, fuel shutoff valves, pressure controls and safety valves. Combustion condition should be assessed from flame appearance, exhaust condition and approved combustion measurements. Pressure-part thickness measurements, valve set points, burner adjustments and water limits must follow class and manufacturer documentation; refer to the manufacturer documentation for the exact figure.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Carry burner consumables and service parts applicable to the installed firing system, ignition and flame-detection components, fuel-valve seals, gauge-glass components, level-control spares, pressure and temperature sensors, manhole/handhole gaskets and feedwater-valve service kits. Pressure-part repair materials must match the approved boiler material specification and repair procedure.
Equipment Model #154098 · ✓ still in production