OceanSphereFree accountLog inDEENPL
OceanSphereENGINES
Library› Engine Room› Boilers› Auxiliary Boiler (Oil-Fired)
Boilers

Auxiliary Boiler (Oil-Fired)

The oil-fired auxiliary boiler makes steam independently of the main engine, covering port and standby periods when an exhaust gas economiser has no waste heat to draw on, and it is chosen over a composite or economiser-only arrangement wherever the ship needs guaranteed steam regardless of engine running state.

726models 158manufacturers
Models

Models in this type.

Models 601 to 700 of 726 in Auxiliary Boiler (Oil-Fired). Every row links to full specifications, documents and service notes.

AUTONAUTIC INSTRUMENTAL, S.L.C20 AUTONAUTIC INSTRUMENTAL, S.L.Certificate MERD00002FG Alltek Marine Electronics CorporationMcMurdo SMARTFIND M6 (Z611) Alltek Marine Electronics CorporationMcMurdo Smartfind S5A AIS SART, Kannad Marine Safelink AIS SART 2, Cobham Sailor 5052 AIS SART (Z650) Böning Automationstechnologie GmbH & Co.KGAHD-DPS02 Böning Automationstechnologie GmbH & Co.KGNaviation lights Serie AHD EKM Co., Ltd.AP8000M EKM Co., Ltd.Certificate MEDD00002GS ELAC SONAR GmbHCertificate MEDD0000589 ELAC SONAR GmbHLAZ 5200 Fincantieri NexTech S.p.A.SEAS-NAVY ECDIS 450 Fincantieri NexTech S.p.A.SEAS-NAVY ECDIS 450 LN Furuno Electric Co., Ltd.Certificate MEDD00002CD Furuno Electric Co., Ltd.Certificate MERD00002CD Hella New Zealand LtdNaviLED 360 2NM All Round Navigation Light Hella New Zealand LtdNaviLED PRO Navigation Lights Jotron ASCertificate MEDD0000296 Jotron ASCertificate MERD0000296 Jotron Skipper ASCertificate MEDD00001AF Jotron Skipper ASCertificate MERD00001AF Liaoning Lida Automation Equipment Manufacturing Co., Ltd.Certificate MEDD000021Z Liaoning Lida Automation Equipment Manufacturing Co., Ltd.OD2-J Optonaval GmbHCertificate MEDD000020Y Optonaval GmbHL30001 UNL Universal Navigation Light, L30002 UNL-S Universal Navigation Light (Side-mounted) PC MaritimeCertificate MEDD000004A PC MaritimeCertificate MERD000004A Peters + Bey GmbHNavigation Lights Type 400, 420, 500, 580, 760, 780 Peters + Bey GmbHPB-NLCP-SA Raymarine LimitedPathfinder 16 CAT3 Radar System Pathfinder 19 CAT3 Radar System Pathfinder 22 CAT2 Radar System Pathfinder 24 CAT2 Radar System Raymarine LimitedPathfinder 27 Radar System / Pathfinder 32 Radar System SAINSEL SISTEMAS NAVALES, S.A.U., S.M.E.Certificate MEDD0000271 SAINSEL SISTEMAS NAVALES, S.A.U., S.M.E.WECDIS 3.0 Saab ABCertificate MEDD0000016 Saab ABSee appendix for product designations Saab TransponderTech ABCertificate MEDD000052E Saab TransponderTech ABCertificate MERD0001N2J Scandinavian Micro Systems ASCertificate MEDD00002BJ Scandinavian Micro Systems ASOptical Bearing Device System SR02 Seastema S.p.A.SEAS-NAVY ECDIS 450 Seastema S.p.A.SEAS-NAVY ECDIS 450 LN TOKYO KEIKI INC. Marine Systems CompanyEC-9000 series Thrane & ThraneSAILOR 6110 GMDSS system Thrane & ThraneSAILOR 6249 Totem Plus Europe GmbHTotem BNWAS Totem Plus Europe GmbHTotem ECDIS Victor SpA.Formula Marine / Formula Marine Leather Victor SpA.Top Driver Marine WISKA Hoppmann GmbHHML- ISO LED WISKA Hoppmann GmbHHML-ISO 35 Weigel Meßgeräte GmbHLSP 96, LSP 144 Weigel Meßgeräte GmbHSERANA-Q 96, SERANA-Q 144 Zöllner SignalCertificate MEDD0000086 Zöllner SignalSound reception device SRD414/4 besecke GmbH & Co. KGCertificate MEDD00001TK besecke GmbH & Co. KGbeWatch em-trak Marine Electronics Ltd.A200 (425-0013) em-trak Marine Electronics Ltd.SART 100 (409-0018) AalborgMission OC 5000 kg/h steam TOKYO KEIKI INC. Yaita PlantHCS-9000 Series Steam capacity per Hersteller-Datenblatt AIK Flammadur Brandschutz GmbHCertificate MEDD000014M AMI MarineVoyage Data Recorder (VDR) (X2 VDR) BOSVIK A/SSpeed BREIZELEC - MANTAGUANavigation Lights NAVIPRO CONSOLITE TECHNOLOGY LIMITED.CTL-9xx Navigation Lights (CTL-9xx Navigation Lights) CSSC Marine Technology Co., Ltd.MFG-I Marine Optic Gyro Compass Canel & Sohn GmbH & Co.Pilot Ladder ComNav Marine, Ltd.X5 (21410006) DECKMA-Decksmaschinen und Automation Vertriebsgesellschaft mit beschränkter HaftungNavigation Light Control System NLS 3000 Daeyang Instrument Co., Ltd.Rudder angle indicator Dr. E. Horn GmbHEAD 96x96 sl-W ... and EAD 144x144sL-S EA 96X92.2 s l W ... and EA 144x144 sl-S... EXAILGyro Compasses EXAIL SASExail Gyro Compasses Eckhard KnollPilot Ladder Erling Vatnes TreprodukterType 18 and Type 19 FLIR TransponderTech ABR6 Navigation System GLAMOX NT Sp. z o.o.Certificate MERD00002EA GME Pty LtdMT606G MT606FG Inelteh d.o.o.ITNSL-01 Jiangsu Lisheng MarinePilot Ladder Jiangyan City Marine Outfitting Co. Ltd.Pilot Ladder Jiangyin Haisheng Marine Outfitting & Decoration Co., Ltd.Certificate MEDD00001Y8 Jiangyin Xijiao Marine Fittings PlantPilot Ladder Jiangyin Yongda Cord Net Co., Ltd.Pilot Ladder K2W Lights UG (haftungsbeschränkt) Co. KGNavigation lights Serie S64 Karl Dose GmbHDaylight Signalling Light HSL & HSL LED Kongsberg Discovery AS Avd SeatexMGC COMPASS R-series LS POWER SOLUTION CO., LTD.KOC-LCP-01 Marine Data Systems Ltd.MD67HR, MD68HR, MD68HRB, MD69BR, MD69BRX, MD71HR, MD71MFD, MD73HR, MD73HR/W, MD74HR, MD74HR/W, MD77HR and MD77HRB McMurdo LimitedZ712 Kannad Marine SAFEPRO PLUS AIS EPIRB NAVANTIA S.A., S.M.E.MINERVAR Radar NAVTOR ASSENC Distribution service NORIS Automation GmbHNORIMETER 3 Nantong Baisheng New Material Technology Co., Ltd.Certificate MEDD00002CW Nantong Saiyang Electronics Co., Ltd.GSL9000, GSL1200 NavicoSIMRAD V5043 Navico RBU Italia S.r.L.SIMRAD R5000 Radar System Navis Engineering OyNavis NavAP OBA Tradizione Futura SrlGarbino Ø 36 OXLEY DEVELOPMENTS COMPANY LIMITEDNavigation lights (IP67) OneOcean Group LimitedSENC Distribution Process
By manufacturer

Manufacturers.

All 158 manufacturers with models of Auxiliary Boiler (Oil-Fired). Names with a manufacturer page open it; the others open a search across the full library.

All manufacturers
Related types

Also in Boilers.

The other equipment types in this category.

Auxiliary BoilerAuxiliary Oil-Fired BoilerBoilerComposite BoilerComposite BoilerExhaust Gas BoilerExhaust Gas EconomizerExhaust Gas EconomizerInert Gas Generator (Tanker)Marine BurnerSteam BoilerThermal Oil HeaterThermal Oil Heater (for tankers)
Knowledge

What to check on a Auxiliary Boiler (Oil-Fired).

Unlike an exhaust gas economiser, which only makes steam from waste heat while the main engine runs, an oil-fired auxiliary boiler burns its own fuel and can raise steam at any time, in port, at anchor, or as a backup if the economiser cannot meet demand at sea. This independence is the entire point of the type: it is sized and operated as the ship's guaranteed steam source, with the economiser treated as a fuel-saving supplement when the main engine is running rather than the primary source.

What defines this type

Unlike an exhaust gas economiser, which only makes steam from waste heat while the main engine runs, an oil-fired auxiliary boiler burns its own fuel and can raise steam at any time, in port, at anchor, or as a backup if the economiser cannot meet demand at sea. This independence is the entire point of the type: it is sized and operated as the ship's guaranteed steam source, with the economiser treated as a fuel-saving supplement when the main engine is running rather than the primary source.

Oil-fired auxiliary boiler cross-section
Side cross-section of an oil-fired smoke-tube auxiliary boiler showing the burner, furnace, fire tube bundle, water level, smoke box and funnel uptake, plus the feedwater inlet and steam outlet connections.

Main components

  • Furnace and combustion chamber – where atomised fuel burns; refractory lining protects the shell from direct flame radiation.
  • Burner – a rotary cup or pressure jet burner atomising the fuel oil, paired with a forced draft fan supplying combustion air.
  • Fuel oil system – heater, pump and atomiser conditioning heavy fuel oil to the viscosity the burner needs, or handling MDO/MGO directly at lower viscosity.
  • Heating surface – smoke tube (fire tube) construction for smaller, simpler boilers, or water tube construction where higher pressure or capacity is needed.
  • Superheater – fitted where the plant needs superheated rather than saturated steam, common on boilers also supplying turbine-driven auxiliaries.
  • Safety valves – set to lift at design pressure and prevent overpressure of the shell.
  • Water level control and gauge glasses – automatic feedwater control plus independent visual gauge glasses, backed by low water level alarms and burner cutout.
  • Soot blowers – steam or air-driven lances that clear soot from the fire side of the heating surface without shutting the boiler down.

Selection and sizing

Sizing is set by the ship's steam demand in port, since that is usually the condition with no exhaust gas heat available at all:

  • Steam capacity in t/h and design pressure in bar against the combined demand of heating, cargo heating on tankers, and hotel load.
  • Fuel flexibility between HFO and distillate, since a boiler that cannot burn MGO cleanly becomes a liability in emission control areas.
  • Smoke tube versus water tube construction, generally a function of required pressure and capacity rather than free choice.
  • Burner turndown ratio, which decides how well the boiler can hold a low, steady load in port without constantly cycling on and off.

Regulations and class

Boiler safety valve capacity, low water level protection and burner management interlocks are checked against SOLAS Chapter II-2 machinery space safety requirements, and class rules set the periodic internal and external survey cycle including hydrostatic testing at boiler renewal survey. Fuel sulphur content burned in the auxiliary boiler falls under the same MARPOL Annex VI fuel sulphur limits that apply to the main engine, so a boiler burning HFO inside an emission control area needs the same fuel changeover discipline as the propulsion plant.

Typical faults

FaultConsequence
Low water level protection failureFurnace tube overheating and potential tube rupture if the burner does not cut out in time
Burner nozzle foulingPoor atomisation, incomplete combustion, soot buildup in the uptake and risk of an uptake fire
Feedwater treatment neglectedScale formation on heating surfaces and internal corrosion, both cutting efficiency and tube life
Safety valve seat leakage or failure to lift at set pressureEither a constant steam loss or, worse, an overpressure event if the valve does not open when needed
Refractory damage from thermal shockRepeated fast heat-up and cool-down cracks the lining, exposing the shell to direct flame

What to look for in a supplier

  • Burner turndown ratio and confirmed fuel flexibility across the fuels the ship actually carries.
  • Class approval and a design pressure certificate matching the vessel's steam service, not a generic shore boiler rating.
  • Spares commonality with the ship's existing boiler platform where this is a replacement rather than a newbuild.
  • Compatibility with the vessel's existing water treatment chemical programme.
  • Practical access for internal tube inspection and soot blower maintenance within the actual boiler room layout.

Never bypass a low water level alarm or cutout to keep steam available during a busy port call; a dry-fired furnace tube fails in minutes, and the boiler is out of service far longer than the alarm nuisance ever cost.

By manufacturer AFRISOWISKASwagelokEndress+HauserAlfa Laval S.p.A.MAN Energy SolutionsWärtsiläABB MarineAlfa LavalMacGregorNovenco MarineseimihanlaimsCarrier MarineSiemens MarineAll manufacturersSpare parts by equipment
Would you like to know more?

One request. A person answers within 24 hours on working days.

Tell us the manufacturer, the model and what you need — a part, a service call, a second opinion. Our desk asks the right suppliers from a network of over 114,000 companies and comes back with a quote or a sourcing plan, not a search page.

Frequently asked

Three things people ask first.

Is Auxiliary Boiler (Oil-Fired) data free?

Yes. Every model page, every guide and every datasheet for this type is readable without an account. An account adds saved searches and requests, nothing is taken away.

My model is missing — what now?

Send us the nameplate. We identify it by hand, add it to the library, and if you need a part or a service, the request is already on our desk.

Can you source a Auxiliary Boiler (Oil-Fired) part?