OceanSphereFree accountLog inDEENPL
OceanSphereENGINES
Library› Engine Room› Boilers› Auxiliary Boiler (Oil-Fired)
Boilers

Auxiliary Boiler (Oil-Fired)

The oil-fired auxiliary boiler makes steam independently of the main engine, covering port and standby periods when an exhaust gas economiser has no waste heat to draw on, and it is chosen over a composite or economiser-only arrangement wherever the ship needs guaranteed steam regardless of engine running state.

726models 158manufacturers
Models

Models in this type.

Models 401 to 500 of 726 in Auxiliary Boiler (Oil-Fired). Every row links to full specifications, documents and service notes.

Alfa LavalAalborg AQ-1 1.0 t/h steam Alfa LavalAalborg AQ-10 10.0 t/h steam Alfa LavalAalborg AQ-12 12.0 t/h steam Alfa LavalAalborg AQ-2 2.0 t/h steam Alfa LavalAalborg AQ-3 3.0 t/h steam Alfa LavalAalborg AQ-5 5.0 t/h steam Alfa LavalAalborg AQ-7 7.0 t/h steam SunrodSB-05 0.5 t/h steam SunrodSB-10 1.0 t/h steam SunrodSB-100 10.0 t/h steam SunrodSB-150 15.0 t/h steam SunrodSB-20 2.0 t/h steam SunrodSB-50 5.0 t/h steam SunrodVS 600 2500 kg/h steam Cassens & Plath GmbH180, 160, Thomson, Sea, 175 Cassens & Plath GmbHBETA/1, BETA/2, BETA/4, IOTA/1, IOTA/2, T12/1, T12/2 with Trade Names: BETA, IOTA, T12 Cassens & Plath GmbHBETA/125 Cassens & Plath GmbHCertificate MEDE000000C Cassens & Plath GmbHCertificate MERE000000C Cassens & Plath GmbHREFLECTA/1 (add. tradename: AlphaBinnacle H Mk2) - Type/11, REFLECTA/2 - Type/12, REFLECTA/1 - Type/4 Cassens & Plath GmbHREFLECTA/3 - Type/21 NACOS Marine GmbHBNWAS Platinum NACOS Marine GmbHCertificate MEDD00000UG NACOS Marine GmbHCertificate MERD00000UG NACOS Marine GmbHECDISPILOT & MULTIPILOT Platinum NACOS Marine GmbHMULTIPILOT Platinum NACOS Marine GmbHPlatinum INS NACOS Marine GmbHTRACKPILOT Platinum Sperry Marine B.V. - German BranchCertificate MEDD00000ZJ Sperry Marine B.V. - German BranchCertificate MERD00000ZJ Sperry Marine B.V. - German BranchJUPITER Sperry Marine B.V. - German BranchNAVIKNOT Types: 350 E, 350 EE, 450 D, 450 DD, 550 DD, 600 S, 600 SD, 600 SDD, 600 SDT and 600 SE Sperry Marine B.V. - German BranchNAVIPILOT 4500N Sperry Marine B.V. - German BranchPV 23 (Type 2535, 2535-AA), PV 24 (Type 2695), PV 25 (Type 5042) Sperry Marine B.V. - German BranchRudder Angle Indicator System Wärtsilä Voyage OYCertificate MEDD000002H Wärtsilä Voyage OYCertificate MERD000002H Wärtsilä Voyage OYMultifunctional Display: Navi-Radar 4000 RADAR, AlphaBridge-T: AlphaRadar-T Wärtsilä Voyage OYMultifunctional Display: Navi-Sailor 4000 ECDIS or Navi-Sailor 4100 ECDIS, AlphaBridge-T: AlphaChart-T Wärtsilä Voyage OYMultifunctional Display: Navi-Watcher 5000 BNWAS Wärtsilä Voyage OYNavi-Sailor 5 ECDIS Wärtsilä Voyage OYTADS Zhejiang Hule Electric Equipment Manufacture Co., Ltd.CXHL Series Navigation Light Zhejiang Hule Electric Equipment Manufacture Co., Ltd.CXHLP series Zhejiang Hule Electric Equipment Manufacture Co., Ltd.Certificate MEDD00001F7 Zhejiang Hule Electric Equipment Manufacture Co., Ltd.HL-8×2M-24D Zhejiang Hule Electric Equipment Manufacture Co., Ltd.Marine portable daylight signaling lamp CXD8 Zhejiang Hule Electric Equipment Manufacture Co., Ltd.Navigation Lights CXH(1/2/3/4/6)-1; CXH(1/2/3/4/6)-2 Zhejiang Hule Electric Equipment Manufacture Co., Ltd.signal lights type CXHL8, CXHL8B Jiangsu Huayan Marine Equipment Co., Ltd.Pilot Ladder Jiangsu Huayan Marine Equipment Co., Ltd.Pilot Ladder HYP-B-B Jiangsu Huayan Marine Equipment Co., Ltd.Pilot Ladder HYP-B-B 4m Jiangsu Huayan Marine Equipment Co., Ltd.Pilot Ladder HYP-B-B 5m Jiangsu Huayan Marine Equipment Co., Ltd.Pilot Ladder HYP-B-B 6m Jiangsu Huayan Marine Equipment Co., Ltd.Pilot Ladder HYP-B-B 9m Metaalwarenfabriek Den Haan Rotterdam B.V.DHR35R-series Navigation Light Metaalwarenfabriek Den Haan Rotterdam B.V.DHR40-series Navigation Light Metaalwarenfabriek Den Haan Rotterdam B.V.DHR55N-series Navigation Light Metaalwarenfabriek Den Haan Rotterdam B.V.DHR60-series Navigation Light Metaalwarenfabriek Den Haan Rotterdam B.V.DHR70N-series Navigation Light Metaalwarenfabriek Den Haan Rotterdam B.V.DHR80-series Navigation Light Navitron Systems Ltd.NT1100 Navitron Systems Ltd.NT850 MK2 RAI, NT1000 MK2 RAI, NT1250 RAI, NT1550 RAI Navitron Systems Ltd.NT951G Navitron Systems Ltd.NT991 BNWAS Navitron Systems Ltd.NT991G MK2 Navitron Systems Ltd.NT995G R. Stahl Tranberg ASCertificate MEDD000006D R. Stahl Tranberg ASCertificate MERD000006D R. Stahl Tranberg ASTEF 2840, TEF 2850, TEF 2870, TEF 2898 R. Stahl Tranberg ASTEF 4800 Commander Navigation Lights Control System R. Stahl Tranberg ASTEF 4900 Commander Navigation Lights Control System R. Stahl Tranberg ASTEF2880 Navigation Light Japan Marina Co., Ltd.Certificate MEDD00002C8 Japan Marina Co., Ltd.F-1000 / NES 4610 / CVR-010 / E-1 Japan Marina Co., Ltd.F-2000 / SAM 4620 / E-2 Japan Marina Co., Ltd.F-3000W / DEBEG 4630 Japan Marina Co., Ltd.NT-1800, NAVTEX 2918 Koden Electronics Co., Ltd.Certificate MEDD000010W Koden Electronics Co., Ltd.Certificate MERD000010W Koden Electronics Co., Ltd.KAT-330 (425-0018) Koden Electronics Co., Ltd.KRS-1611P KRS-1911P KRS-1211P KRS-1411P Koden Electronics Co., Ltd.MDC-7012P, MDC-7025P, MDC-7912P and MDC-7925P Marine Technologies LLCBridge Mate HCS Marine Technologies LLCBridge Mate Propulsion Display Marine Technologies LLCBridge Mate Radar Nautoscan NX Marine Technologies LLCBridgeMate ECDIS Marine Technologies LLCCertificate MEDD00001WA MitsubishiMAC-B Series (MAC-20B through MAC-110B) MitsubishiMAC-HB Series MitsubishiMC-D Series MitsubishiMC-EF Series (MC-50EF, MC-60EF, MC-70EF, MC-80EF) MitsubishiMJC Series (MJC-250F, MJC-280F, MJC-340F, MJC-360F) OSI Maritime SystemsCertificate MEDD00001N0 OSI Maritime SystemsCertificate MERD00001N0 OSI Maritime SystemsECPINS Tradename: WECDIS, ECPINS Warship, ECPINS Submarine, ECPINS-W, ECPINS-W Sub, ECPINS 5000, ECPINS 6 OSI Maritime SystemsIntegrated Navigation & Tactical System (INTS) OSI Maritime SystemsSAAB R5 Supreme AIS with MKD ECPINS, Trade Name: SAAB R5 Supreme AIS, ECPINS W-AIS or SAAB R6 Supreme AIS with MKD ECPINS, Trade Name: SAAB R6 Supreme AIS, ECPINS W-AIS SAL Navigation ABCertificate MEDD00001Y1 SAL Navigation ABMER-D
By manufacturer

Manufacturers.

All 158 manufacturers with models of Auxiliary Boiler (Oil-Fired). Names with a manufacturer page open it; the others open a search across the full library.

All manufacturers
Related types

Also in Boilers.

The other equipment types in this category.

Auxiliary BoilerAuxiliary Oil-Fired BoilerBoilerComposite BoilerComposite BoilerExhaust Gas BoilerExhaust Gas EconomizerExhaust Gas EconomizerInert Gas Generator (Tanker)Marine BurnerSteam BoilerThermal Oil HeaterThermal Oil Heater (for tankers)
Knowledge

What to check on a Auxiliary Boiler (Oil-Fired).

Unlike an exhaust gas economiser, which only makes steam from waste heat while the main engine runs, an oil-fired auxiliary boiler burns its own fuel and can raise steam at any time, in port, at anchor, or as a backup if the economiser cannot meet demand at sea. This independence is the entire point of the type: it is sized and operated as the ship's guaranteed steam source, with the economiser treated as a fuel-saving supplement when the main engine is running rather than the primary source.

What defines this type

Unlike an exhaust gas economiser, which only makes steam from waste heat while the main engine runs, an oil-fired auxiliary boiler burns its own fuel and can raise steam at any time, in port, at anchor, or as a backup if the economiser cannot meet demand at sea. This independence is the entire point of the type: it is sized and operated as the ship's guaranteed steam source, with the economiser treated as a fuel-saving supplement when the main engine is running rather than the primary source.

Oil-fired auxiliary boiler cross-section
Side cross-section of an oil-fired smoke-tube auxiliary boiler showing the burner, furnace, fire tube bundle, water level, smoke box and funnel uptake, plus the feedwater inlet and steam outlet connections.

Main components

  • Furnace and combustion chamber – where atomised fuel burns; refractory lining protects the shell from direct flame radiation.
  • Burner – a rotary cup or pressure jet burner atomising the fuel oil, paired with a forced draft fan supplying combustion air.
  • Fuel oil system – heater, pump and atomiser conditioning heavy fuel oil to the viscosity the burner needs, or handling MDO/MGO directly at lower viscosity.
  • Heating surface – smoke tube (fire tube) construction for smaller, simpler boilers, or water tube construction where higher pressure or capacity is needed.
  • Superheater – fitted where the plant needs superheated rather than saturated steam, common on boilers also supplying turbine-driven auxiliaries.
  • Safety valves – set to lift at design pressure and prevent overpressure of the shell.
  • Water level control and gauge glasses – automatic feedwater control plus independent visual gauge glasses, backed by low water level alarms and burner cutout.
  • Soot blowers – steam or air-driven lances that clear soot from the fire side of the heating surface without shutting the boiler down.

Selection and sizing

Sizing is set by the ship's steam demand in port, since that is usually the condition with no exhaust gas heat available at all:

  • Steam capacity in t/h and design pressure in bar against the combined demand of heating, cargo heating on tankers, and hotel load.
  • Fuel flexibility between HFO and distillate, since a boiler that cannot burn MGO cleanly becomes a liability in emission control areas.
  • Smoke tube versus water tube construction, generally a function of required pressure and capacity rather than free choice.
  • Burner turndown ratio, which decides how well the boiler can hold a low, steady load in port without constantly cycling on and off.

Regulations and class

Boiler safety valve capacity, low water level protection and burner management interlocks are checked against SOLAS Chapter II-2 machinery space safety requirements, and class rules set the periodic internal and external survey cycle including hydrostatic testing at boiler renewal survey. Fuel sulphur content burned in the auxiliary boiler falls under the same MARPOL Annex VI fuel sulphur limits that apply to the main engine, so a boiler burning HFO inside an emission control area needs the same fuel changeover discipline as the propulsion plant.

Typical faults

FaultConsequence
Low water level protection failureFurnace tube overheating and potential tube rupture if the burner does not cut out in time
Burner nozzle foulingPoor atomisation, incomplete combustion, soot buildup in the uptake and risk of an uptake fire
Feedwater treatment neglectedScale formation on heating surfaces and internal corrosion, both cutting efficiency and tube life
Safety valve seat leakage or failure to lift at set pressureEither a constant steam loss or, worse, an overpressure event if the valve does not open when needed
Refractory damage from thermal shockRepeated fast heat-up and cool-down cracks the lining, exposing the shell to direct flame

What to look for in a supplier

  • Burner turndown ratio and confirmed fuel flexibility across the fuels the ship actually carries.
  • Class approval and a design pressure certificate matching the vessel's steam service, not a generic shore boiler rating.
  • Spares commonality with the ship's existing boiler platform where this is a replacement rather than a newbuild.
  • Compatibility with the vessel's existing water treatment chemical programme.
  • Practical access for internal tube inspection and soot blower maintenance within the actual boiler room layout.

Never bypass a low water level alarm or cutout to keep steam available during a busy port call; a dry-fired furnace tube fails in minutes, and the boiler is out of service far longer than the alarm nuisance ever cost.

By manufacturer AFRISOWISKASwagelokEndress+HauserAlfa Laval S.p.A.MAN Energy SolutionsWärtsiläABB MarineAlfa LavalMacGregorNovenco MarineseimihanlaimsCarrier MarineSiemens MarineAll manufacturersSpare parts by equipment
Would you like to know more?

One request. A person answers within 24 hours on working days.

Tell us the manufacturer, the model and what you need — a part, a service call, a second opinion. Our desk asks the right suppliers from a network of over 114,000 companies and comes back with a quote or a sourcing plan, not a search page.

Frequently asked

Three things people ask first.

Is Auxiliary Boiler (Oil-Fired) data free?

Yes. Every model page, every guide and every datasheet for this type is readable without an account. An account adds saved searches and requests, nothing is taken away.

My model is missing — what now?

Send us the nameplate. We identify it by hand, add it to the library, and if you need a part or a service, the request is already on our desk.

Can you source a Auxiliary Boiler (Oil-Fired) part?

Yes. Tell us the manufacturer, the model and what you need — our desk asks the right suppliers from a network of over 114,000 companies and comes back with a quote or a sourcing plan.