Auxiliary Boiler (Oil-Fired)
The oil-fired auxiliary boiler makes steam independently of the main engine, covering port and standby periods when an exhaust gas economiser has no waste heat to draw on, and it is chosen over a composite or economiser-only arrangement wherever the ship needs guaranteed steam regardless of engine running state.
What to check on an Auxiliary Boiler (Oil-Fired).
5 models from Mitsubishi in Auxiliary Boiler (Oil-Fired). Below: the full model list.
What defines this type
Unlike an exhaust gas economiser, which only makes steam from waste heat while the main engine runs, an oil-fired auxiliary boiler burns its own fuel and can raise steam at any time, in port, at anchor, or as a backup if the economiser cannot meet demand at sea. This independence is the entire point of the type: it is sized and operated as the ship's guaranteed steam source, with the economiser treated as a fuel-saving supplement when the main engine is running rather than the primary source.
Legend
- feedwater inlet
- to funnel / uptake
- boiler shell
- steam outlet
- fire tube bundle
- smoke box
- water level
- burner
- furnace tube
Main components
- Furnace and combustion chamber – where atomised fuel burns; refractory lining protects the shell from direct flame radiation.
- Burner – a rotary cup or pressure jet burner atomising the fuel oil, paired with a forced draft fan supplying combustion air.
- Fuel oil system – heater, pump and atomiser conditioning heavy fuel oil to the viscosity the burner needs, or handling MDO/MGO directly at lower viscosity.
- Heating surface – smoke tube (fire tube) construction for smaller, simpler boilers, or water tube construction where higher pressure or capacity is needed.
- Superheater – fitted where the plant needs superheated rather than saturated steam, common on boilers also supplying turbine-driven auxiliaries.
- Safety valves – set to lift at design pressure and prevent overpressure of the shell.
- Water level control and gauge glasses – automatic feedwater control plus independent visual gauge glasses, backed by low water level alarms and burner cutout.
- Soot blowers – steam or air-driven lances that clear soot from the fire side of the heating surface without shutting the boiler down.
Selection and sizing
Sizing is set by the ship's steam demand in port, since that is usually the condition with no exhaust gas heat available at all:
- Steam capacity in t/h and design pressure in bar against the combined demand of heating, cargo heating on tankers, and hotel load.
- Fuel flexibility between HFO and distillate, since a boiler that cannot burn MGO cleanly becomes a liability in emission control areas.
- Smoke tube versus water tube construction, generally a function of required pressure and capacity rather than free choice.
- Burner turndown ratio, which decides how well the boiler can hold a low, steady load in port without constantly cycling on and off.
Regulations and class
Boiler safety valve capacity, low water level protection and burner management interlocks are checked against SOLAS Chapter II-2 machinery space safety requirements, and class rules set the periodic internal and external survey cycle including hydrostatic testing at boiler renewal survey. Fuel sulphur content burned in the auxiliary boiler falls under the same MARPOL Annex VI fuel sulphur limits that apply to the main engine, so a boiler burning HFO inside an emission control area needs the same fuel changeover discipline as the propulsion plant.
Read the full guide
Typical faults
| Fault | Consequence |
|---|---|
| Low water level protection failure | Furnace tube overheating and potential tube rupture if the burner does not cut out in time |
| Burner nozzle fouling | Poor atomisation, incomplete combustion, soot buildup in the uptake and risk of an uptake fire |
| Feedwater treatment neglected | Scale formation on heating surfaces and internal corrosion, both cutting efficiency and tube life |
| Safety valve seat leakage or failure to lift at set pressure | Either a constant steam loss or, worse, an overpressure event if the valve does not open when needed |
| Refractory damage from thermal shock | Repeated fast heat-up and cool-down cracks the lining, exposing the shell to direct flame |
What to look for in a supplier
- Burner turndown ratio and confirmed fuel flexibility across the fuels the ship actually carries.
- Class approval and a design pressure certificate matching the vessel's steam service, not a generic shore boiler rating.
- Spares commonality with the ship's existing boiler platform where this is a replacement rather than a newbuild.
- Compatibility with the vessel's existing water treatment chemical programme.
- Practical access for internal tube inspection and soot blower maintenance within the actual boiler room layout.
Never bypass a low water level alarm or cutout to keep steam available during a busy port call; a dry-fired furnace tube fails in minutes, and the boiler is out of service far longer than the alarm nuisance ever cost.
Models in this type.
The best-documented model of each manufacturer first, then the next — 5 of 5 models in Auxiliary Boiler (Oil-Fired). Every row links to full specifications, documents and service notes.
Manufacturers.
All 77 manufacturers with models of Auxiliary Boiler (Oil-Fired). Names with a manufacturer page open it; the others open a search across the full library.
All manufacturersShow all 77 manufacturers
- AIK Flammadur Brandschutz1
- AVANTIX SASU1
- besecke GmbH & Co. KG1
- ChartWorld International Ltd1
- EKM Co., Ltd.1
- ELAC SONAR GmbH1
- EMRI1
- FLIR TransponderTech AB1
- GLAMOX NT Sp. z o.o.1
- Haixing Maritime Electric Group Co. Ltd.1
- HD Hyundai Marine Solution Co., Ltd.1
- Japan Marina1
- Jiangsu Highland Integration Technology1
- Jiangyin Haisheng Marine Outfitting & Decoration Co., Ltd.1
- Lars Thrane1
- Liaoning Lida Automation Equipment Manufacturing Co., Ltd.1
- Marine Technologies LLC1
- Nantong Baisheng New Material Technology Co., Ltd.1
- Optonaval1
- Peters + Bey GmbH1
- SAAB TransponderTech1
- Saacke Qingdao Marine Boiler Co., Ltd.1
- SAINSEL SISTEMAS NAVALES, S.A.U., S.M.E.1
- Scandinavian Micro Systems1
- Seall ECDIS Limited2
- sm electrics GmbH services & more2
- SPDE 'Musson-Morsviaz-Servis'1
- SRT Marine Systems plc1
- Taicang City Haisheng Marine Fittings Co., Ltd.1
- Tecklenborg, Kegel GmbH1
- Telko2
- Thrane & Thrane A/S Trading as Cobham Satcom2
- Ulmatec Pyro AS1
- UNILUX GEOMAR, S.A.1
- Vard Electro AS2
- Wärtsilä Voyage2
- Weigel Meßgeräte1
- Wuxi Jinbaishen Furniture Co., Ltd.1
- Yantai Navigation Machinery Co. Ltd.1
- Zhejiang Hule Electric Equipment Manufacture Co., Ltd.1
- Zöllner Signal1
Also in Boilers.
The other equipment types in this category.
One request. A person reads it and replies by e-mail.
Tell us the manufacturer, the model and what you need — a part, a service call, a second opinion. A person reads every request and replies by e-mail.
No details at hand? A photo of the rating plate or the part is enough — simply attach it to the request.
Three things people ask first.
Is Auxiliary Boiler (Oil-Fired) data free?
Yes. Every model page, every guide and every datasheet for this type is readable without an account. An account adds saved searches and requests, nothing is taken away.
My model is missing — what now?
Send us the nameplate. We identify it by hand, add it to the library, and if you need a part or a service, the request is already on our desk.
Can you source a Auxiliary Boiler (Oil-Fired) part?
Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.