Alfa Laval Aalborg-XS-TC7A-16bar compact exhaust gas economizer (compact exhaust gas economizer). Evaporation 4800 kg/h, design pressure 16 bar, heating surface 100 m2, weight 9800 kg. Compact, vertically-mounted exhaust-gas waste heat boiler.

Alfa Laval S.p.A. Alfa Laval Aalborg-XS-TC7A-16bar
0.1 to 2.0 t/h steam capacity
Capacity
diameter 1090-1550 mm, height 2800-4600 mm (incl. insulation)
Dimensions

Inspector Detail

Common issues

  • Soot fire risk from unburned fuel deposits accumulating on the exhaust gas side
  • Tube fouling on the gas side reducing heat transfer and raising exhaust back-pressure
  • Tube corrosion/leakage, particularly acid dew-point corrosion during extended low-load or slow-steaming operation
  • Soot blower malfunction reducing cleaning effectiveness
  • Waterside scaling from inadequate feed water treatment
  • Rising exhaust gas outlet temperature or differential pressure signalling fouling or an incipient soot fire

Inspection checklist

  • Check exhaust gas side for soot buildup at scheduled openings
  • Monitor exhaust gas differential pressure and temperature drop trend
  • Inspect tubes for corrosion or leakage on both gas and water sides
  • Check soot blower operation and coverage
  • Verify safety valve set pressure and reseating
  • Check water level control and low-water alarms
  • Watch for an unexplained rise in gas outlet temperature - possible indicator of a soot fire
  • Review feed water treatment and blowdown records
  • Check economizer bypass damper operation if fitted
  • Inspect insulation/lagging for hot spots or damage

Service intervals

Soot blowing daily/per running hours whenever the main engine is running
Exhaust gas side inspection every 4,000-8,000 running hours or at each class survey opening
Safety valve function test annually
Feed water treatment/TDS check weekly
Internal waterside inspection at each class survey opening
Bypass damper function check per maker interval

Typical wear limits

Tube wall thickness class societies require retention of a minimum percentage of original design thickness before renewal - confirm the specific figure against the vessel's classification rules and the Alfa Laval Aalborg manual, do not estimate on board
Low-load corrosion acid dew-point corrosion can locally thin tubes faster than general wear - monitor via UT gauging rather than assuming a uniform rate

Ranges are typical for this design class. Always confirm against the manufacturer documentation for your serial number.

Critical spares

  • Soot blower nozzle/element
  • Safety valve spring and seat set
  • Tube plugs for isolating a leaking tube
  • Manway/inspection door gasket set
  • Feed check valve
  • Water level gauge glass

Safety

  • Soot fire risk - accumulated unburned fuel deposits on the exhaust side can ignite and cause severe damage; fixed fire-fighting/water-washing arrangements must be maintained ready for use
  • Hot exhaust gas surfaces
  • Pressurized steam and hot water
  • Confined space entry required for internal cleaning/inspection - test atmosphere before entry
  • Working at height on this vertically-mounted unit

Class survey

Exhaust gas economizers are Continuous Survey Machinery items with particular attention to soot fire prevention arrangements; class reviews internal/external inspection records and safety valve certificates, and increasingly requires enhanced inspection for vessels operating extensively at low load due to known cold-corrosion risk.

Estimated lifetime: Exhaust gas economizers on vessels with extensive slow-steaming/low-load operation often need tube renewal within 8-15 years due to cold corrosion; well-operated units with good soot management can reach the vessel's service life with periodic tube renewal.

Components & Design

Component data being added…

Technical Data

boiler type Alfa Laval Aalborg Exhaust Gas Boiler / Economizer (Abgaskessel / Abgaswärmetauscher)
weight range kg 600-13000
diameter range mm 1090-1550
height range mm 2800-4600
source manufacturer datasheet

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Rohrverschlammung / Rußabbrand-Gefahr (Soot Fouling)

Visual inspection of gas side for soot buildup, exhaust temperature measurement: >10-20°C above setpoint indicates sludging; perform water flushing kit application (50 l/min, 0.4-0.6 MPa pressure); operate Soot-Blower daily 3x (caution: In case of uptake fire DO NOT blow down with steam due to H₂ fire hazard)

Rohrleckage / Korrosion / Erosion (Tube Leakage)

Internal inspection test (opening of sight glasses/hand ports): inspect tubes for wear, pitting, thinning; external inspection for soot deposits, blistering, sag; perform hydraulic pressure test at 1.25 × operating pressure for maximum 10 minutes

Druckbehälter-Klassbesichtigung / Periodische Inspektion

Class surveyor: Inspect all boilers >3.5 bar working pressure and >4.65 m² heating surface. Frequency: DNV/LLOYDS every 2 years up to 8 years old, then annually; 2 comprehensive internal inspections per 5-year period, interval maximum 36 months. Inspect internal surfaces (drums, headers) for sludging, corrosion, cracks.

Sicherheitsventile / Überdruckschutz

Safety valve test: opening at ≤3% above working pressure; test pressure 15% above working pressure for maximum 10 minutes (feedwater only for water level safety); pressure rise during test maximum 10% above design pressure at full load firing with stop valves closed.

Wasserspiegel-Schauglas / Schutzeinrichtungen

Sight glass visual inspection for highest, lowest, normal water level markings; protective devices without sight obstruction; test water cushion safety ball valve for function; check drain line for safety.

Refractory / furnace room (only for fired boilers); tube bundle cleaning (XS-TC7A helix tubes)

For Aalborg OL/D and similar burner boilers: inspect refractory material (membrane walls, furnace floor) for cracks, deformation, separation; remove carbon deposits. For XS-TC7A: clean helix tube bundle with water flush kit (7–8 hours on similar ships), if necessary add cleaning chemicals before discharge to slop tank.

Type-general inspection and maintenance points for this equipment category — not model-specific.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →
Equipment Model #66215 · ✓ still in production