Epoxy primer cures by chemical cross-linking between a resin and a curing agent rather than by solvent evaporation, which gives it the low permeability ballast tank and hull coatings need, but also means mixing ratio, pot life and recoat window all matter more than with a single-pack paint.

PPG / Sigma Coatings
Knowledge

What to check on an Epoxy Primer.

72 models from PPG / Sigma Coatings in Epoxy Primer. Below: the full model list.

What Makes an Epoxy Primer Different

Epoxy primer is a two-component coating: a resin and a polyamide or amine curing agent that react chemically once mixed, cross-linking into a dense film rather than simply drying as solvent evaporates the way an alkyd primer does. That cross-linked structure is what gives it low permeability and strong adhesion to correctly prepared steel, and it is why epoxy primer is the standard choice under ballast tank, cargo hold and hull coating systems. It differs from a zinc-rich primer, which protects sacrificially rather than as a barrier, from a shop primer, a thin weldable coating meant only to protect steel during fabrication and not to serve as a system coat, and from surface-tolerant epoxy variants formulated to bond over marginal, hand-tool-cleaned steel rather than a full abrasive blast.

Epoxy primer, mixing and applied film
Left, the two components of an epoxy primer, resin and curing agent, combined into a mixed pot of limited pot life and applied to the surface. Right, a cross-section of the cured primer film on a blast-profiled steel substrate with its dry film thickness marked.

Legend

  1. component A, resin
  2. component B, curing agent
  3. applied by brush, roller or spray
  4. epoxy primer coat
  5. dry film thickness (DFT)
  6. steel substrate, blast profile
  7. mixed pot, limited pot life

Main Types and Where They Are Used

  • Standard epoxy primer – applied over blast-cleaned steel for ballast tanks, cargo holds and the hull under antifouling.
  • Surface-tolerant epoxy – formulated for maintenance touch-up on rusted or pitted steel where full re-blasting is not practical.
  • Coal tar epoxy – an older formulation still found in service, though largely phased out of new construction for health and VOC reasons.
  • Contrast-shaded epoxy primer – pigmented differently from the stripe or topcoat specifically so thin spots and holidays show up during inspection.

Application and Sizing Considerations

Dry film thickness is usually targeted in the range of roughly 100 to 150 microns per coat, with extra stripe coats worked into welds and edges where the film naturally thins. Pot life once the two components are mixed is limited and shortens sharply as ambient temperature rises, so mixed quantities have to match what can actually be applied within that window. Surface preparation grade drives adhesion and service life more than almost any other variable, and there is a defined overcoating window between primer and the next coat: recoat too late and the surface needs re-abrading before the next coat will bond properly.

Regulations and Class

New vessels are covered by the IMO Performance Standard for Protective Coatings for ballast tanks and void spaces, which sets minimum dry film thickness, required surface preparation, and demands that the coating system itself be type-approved and tested against the standard, not just individually compliant products applied in any combination. Class surveyors assess coating condition and breakdown during hull and tank surveys, and the extent of coating breakdown found can directly affect how much close-up survey and thickness measurement is required.

Read the full guide

Typical Faults

FaultConsequence
Insufficient surface preparation, residual rust or saltEarly adhesion failure and blistering
Overcoating outside the recoat window without re-abradingIntercoat delamination between primer and topcoat
Application below minimum temperature or dew point marginPoor cure, amine blush on the surface, reduced hardness
Incorrect mixing ratio or inadequate induction timeIncomplete cure, a soft or tacky film that never fully hardens
Thin film at welds and edges (edge effect)Premature corrosion starting at these high-stress points despite good flat-area coverage

What to Look for in a Supplier

  • A valid Performance Standard for Protective Coatings type-approval certificate where the product is destined for ballast tanks or void spaces.
  • A technical data sheet with dry film thickness range, pot life and recoat window matched to the yard or repair conditions expected.
  • Batch traceability and clear shelf-life and storage guidance, since epoxy components degrade if stored badly before use.
  • Field technical support for application supervision, not only product supply.

Touch-dry is not the same as fully cured; ballast tanks coated with epoxy primer should not be filled until the manufacturer's full cure time has passed, which is longer than the time it takes for the surface to stop feeling tacky.

Models

Models in this type.

The best-documented model of each manufacturer first, then the next — 72 of 72 models in Epoxy Primer. Every row links to full specifications, documents and service notes.

Showing only PPG / Sigma Coatings. Show all manufacturers
PPG / Sigma Coatings109 HS PPG / Sigma Coatings880 ALU PPG / Sigma CoatingsAluminium Primer PPG / Sigma CoatingsChlorinated Rubber Primer PPG / Sigma CoatingsDegreaser PPG / Sigma CoatingsPrimer for Aluminium-C PPG / Sigma CoatingsPrimer for Concrete-C PPG / Sigma CoatingsPrimer for GRP/FRP-C PPG / Sigma CoatingsPrimer for Galvanized Steel-C PPG / Sigma CoatingsPrimer for Mild Steel-C PPG / Sigma CoatingsPrimer for Stainless Steel-C PPG / Sigma CoatingsSurface Cleaner PPG / Sigma CoatingsThinner No.1 PPG / Sigma CoatingsThinner No.2 PPG / Sigma CoatingsThinner No.5 PPG / Sigma CoatingsVinyl Tar Primer PPG / Sigma CoatingsWeld-Through Primer PPG / Sigma CoatingsZinc Epoxy Primer PPG / Sigma CoatingsZinc Silicate Primer PPG / Sigma CoatingsSIGMACover 256 PPG / Sigma CoatingsSIGMACover 435 PPG / Sigma CoatingsSIGMACover 522 PPG / Sigma CoatingsPrimer Bilge PPG / Sigma CoatingsPrimer Boot Topping PPG / Sigma CoatingsPrimer Chain Locker PPG / Sigma CoatingsPrimer Deck House PPG / Sigma CoatingsPrimer Dry Dock Block PPG / Sigma CoatingsPrimer Engine Room PPG / Sigma CoatingsPrimer Funnel/Stack PPG / Sigma CoatingsPrimer Hull Bottom PPG / Sigma CoatingsPrimer Hull Vertical PPG / Sigma CoatingsPrimer Mast/Derrick PPG / Sigma CoatingsPrimer Pipe External PPG / Sigma CoatingsPrimer Pipe Internal PPG / Sigma CoatingsPrimer Superstructure PPG / Sigma CoatingsPrimer Void Space PPG / Sigma CoatingsPrimer Waterline PPG / Sigma CoatingsSigmaCover 211 PPG / Sigma CoatingsSigmaCover 256 PPG / Sigma CoatingsSigmaCover 280 PPG / Sigma CoatingsSigmaCover 435 PPG / Sigma CoatingsSigmaCover 456 PPG / Sigma CoatingsSigmaCover 456 10L-C PPG / Sigma CoatingsSigmaCover 456 15L-C PPG / Sigma CoatingsSigmaCover 456 1L-C PPG / Sigma CoatingsSigmaCover 456 20L-C PPG / Sigma CoatingsSigmaCover 456 5L-C PPG / Sigma CoatingsSigmaCover 510 PPG / Sigma CoatingsSigmaCover 522 PPG / Sigma CoatingsSigmaCover 566 PPG / Sigma CoatingsSigmaCover 630 PPG / Sigma CoatingsSigmaCover 630 GF PPG / Sigma CoatingsSigmaPrime 200 PPG / Sigma CoatingsSigmaShield 880 PPG / Sigma CoatingsSigmaShield 880 10L-C PPG / Sigma CoatingsSigmaShield 880 15L-C PPG / Sigma CoatingsSigmaShield 880 1L-C PPG / Sigma CoatingsSigmaShield 880 2.5L-C PPG / Sigma CoatingsSigmaShield 880 20L-C PPG / Sigma CoatingsSigmaShield 880 5L-C PPG / Sigma CoatingsSigmaZinc 109HS Shop Primer PPG / Sigma CoatingsSIGMACover 1500 PPG / Sigma CoatingsSIGMACover 211 PPG / Sigma CoatingsSIGMACover 300 PPG / Sigma CoatingsSIGMACover 480 PPG / Sigma CoatingsSIGMACover 566 PPG / Sigma CoatingsSIGMACover 805 PPG / Sigma CoatingsSigmaCover 456 2.5L-C PPG / Sigma CoatingsSigmaCover 480 PPG / Sigma CoatingsSigmaCover 515 PPG / Sigma CoatingsSigmaCover 525 PPG / Sigma CoatingsSigmaCover 900
72 models
More than the data sheet shows

Write to us about this model — the answer comes by e-mail.

Name the make and the model and what the job is: a spare, a service call, a second opinion on a data sheet. We answer by e-mail.

No details at hand? A photo of the rating plate or the part is enough — simply attach it to the request.

Frequently asked

Questions that come up with this equipment.

Is Epoxy Primer data free?

Yes. Every model page, every guide and every datasheet for this type is readable without an account. An account adds saved searches and requests, nothing is taken away.

My model is missing — what now?

Send us the nameplate. We identify it by hand, add it to the library, and if you need a part or a service, the request is already on our desk.

Can you source a Epoxy Primer part?

Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.