Skip to content
OceanSphereENGINES
Library› Engine Room› Pumps› Progressive Cavity Pump
Pumps

Progressive Cavity Pump

A progressive cavity pump moves fluid with a helical rotor turning inside a matching elastomeric stator rather than with impeller or piston action, which is why it handles sludge, viscous residues and solids-laden fluids that would clog a centrifugal pump or wreck a piston pump's seals.

INOXPA
Knowledge

What to check on a Progressive Cavity Pump.

11 models from INOXPA in Progressive Cavity Pump. Below: the full model list.

What sets the progressive cavity pump apart

Most shipboard pumps are centrifugal, which move large volumes of thin, clean liquid efficiently but lose performance fast as viscosity rises or as solids appear in the fluid. A progressive cavity, or mono, pump works differently: a single helical rotor turns inside a double-helix elastomeric stator, and the two together form a sealed cavity that moves progressively along the pump as the rotor turns, carrying the fluid at a constant, positive displacement independent of viscosity. This is why mono pumps are the standard choice for sludge, waste oil, bilge water with debris, and viscous or shear-sensitive chemicals, service where a centrifugal pump would lose prime or clog.

Progressive cavity pump, longitudinal section
Section through a progressive cavity pump showing the suction chamber, the helical steel rotor turning inside its elastomeric stator, the connecting rod and universal joints linking rotor to drive shaft, and the discharge port.

Legend

  1. suction port
  2. discharge port
  3. stator (elastomer, double helix)
  4. drive shaft
  5. rotor (single helix, steel)
  6. connecting rod & universal joints
  7. to gearbox / motor

Main components

Rotor

A single helical screw, usually hard-chrome-plated steel, precision-ground to the stator's internal profile.

Stator

A double-internal-helix elastomer moulded inside a steel tube; the elastomer compound is selected for compatibility with the fluid pumped and is the component that wears and needs periodic replacement.

Read the full guide

Universal joints

Because the rotor follows an eccentric path while the drive shaft rotates concentrically, a flexible connection is needed between them; this joint is a common wear point under high-solids service.

Shaft seal

Mechanical seal or packed gland at the drive end; the seal has to handle whatever pressure the pump generates, which for mono pumps can be significant even at low flow.

Selection and sizing

  • Flow rate against differential pressure required, noting that mono pump flow drops roughly linearly with rising back-pressure, unlike a centrifugal pump's curve.
  • Solids handling capability: maximum particle size and percentage solids the specific rotor/stator geometry is rated for.
  • Elastomer compatibility with the actual fluid, including any cleaning chemicals used in the same line, since an incompatible elastomer swells or degrades quickly.
  • Dry-run tolerance: some mono pump designs tolerate brief dry running, common in bilge and sludge service, better than others.

Regulations and class

Where a progressive cavity pump serves an oily bilge water or sludge system, its installation falls under MARPOL Annex I requirements for the associated oil filtering and discharge monitoring equipment rather than the pump itself being separately regulated. Class rules require the pump and its piping to meet the applicable machinery installation and piping requirements for the system served, and periodic survey of bilge and sludge pumping arrangements is part of the vessel's routine class survey.

Typical faults

FaultCauseConsequence
Rapid stator wearDry running beyond the elastomer's tolerance, or an incompatible fluidLoss of flow and pressure, eventual total loss of pumping capacity
Universal joint failureHigh-solids or abrasive service without adequate joint protection or lubricationLoss of drive to the rotor, sudden pump stoppage
Seal leakageMechanical seal not rated for the pump's actual discharge pressureProduct loss, and in oily-water service a pollution and reporting issue
Overheating on closed dischargeValve left shut against a running positive-displacement pumpRapid pressure rise, potential pipe or seal failure, unlike a centrifugal pump which just deadheads

What to look for in a supplier

  • Elastomer options and documented chemical compatibility data for the actual service fluid.
  • Rotor and stator available as a matched wear-set, since mixing worn and new parts degrades performance.
  • Relief valve or bypass fitted or recommended for the installation, given the pump's positive-displacement deadhead risk.
  • Spares availability and interchangeability with the pump already in service, to avoid holding parallel spares inventories.

Never run a mono pump against a closed discharge valve, even briefly; unlike a centrifugal pump it will keep building pressure until something gives, most often the stator or a downstream fitting.

Models

Models in this type.

The best-documented model of each manufacturer first, then the next — 11 of 11 models in Progressive Cavity Pump. Every row links to full specifications, documents and service notes.

Showing only INOXPA. Show all manufacturers
By manufacturer

Manufacturers.

All 12 manufacturers with models of Progressive Cavity Pump. Names with a manufacturer page open it; the others open a search across the full library.

All manufacturers in the library
More than the data sheet shows

Write to us about this model — the answer comes by e-mail.

Name the make and the model and what the job is: a spare, a service call, a second opinion on a data sheet. We answer by e-mail.

No details at hand? A photo of the rating plate or the part is enough — simply attach it to the request.

Frequently asked

Questions that come up with this equipment.

Is Progressive Cavity Pump data free?

Yes. Every model page, every guide and every datasheet for this type is readable without an account. An account adds saved searches and requests, nothing is taken away.

My model is missing — what now?

Send us the nameplate. We identify it by hand, add it to the library, and if you need a part or a service, the request is already on our desk.

Can you source a Progressive Cavity Pump part?

Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.