Fire Pump (Main + Emergency)

SOLAS requires two independent means of pumping seawater into the fire main: a main fire pump and a fully separate emergency pump outside the space that could disable the first. Neither may share a single point of failure with the other.

304models 29manufacturers
Models

Models in this type.

The 100 models with the most complete data of 304 in Fire Pump (Main + Emergency). Every row links to full specifications, documents and service notes.

Grundfos MarineCRN-10-10 Grundfos MarineCRN-10-15 Grundfos MarineCRN-10-20 Grundfos MarineCRN-10-30 Grundfos MarineCRN-10-45 Grundfos MarineCRN-10-5 Grundfos MarineCRN-120-10 Grundfos MarineCRN-120-15 Grundfos MarineCRN-120-20 Grundfos MarineCRN-120-30 Grundfos MarineCRN-120-45 Grundfos MarineCRN-120-5 Grundfos MarineCRN-15-10 Grundfos MarineCRN-15-15 Grundfos MarineCRN-15-20 Grundfos MarineCRN-15-30 Grundfos MarineCRN-15-45 Grundfos MarineCRN-15-5 Grundfos MarineCRN-150-10 Grundfos MarineCRN-150-15 Grundfos MarineCRN-150-20 Grundfos MarineCRN-150-30 Grundfos MarineCRN-150-45 Grundfos MarineCRN-150-5 Grundfos MarineCRN-20-10 Grundfos MarineCRN-20-15 Grundfos MarineCRN-20-20 Grundfos MarineCRN-20-30 Grundfos MarineCRN-20-45 Grundfos MarineCRN-20-5 Grundfos MarineCRN-3-10 Grundfos MarineCRN-3-15 Grundfos MarineCRN-3-20 Grundfos MarineCRN-3-30 Grundfos MarineCRN-3-45 Grundfos MarineCRN-3-5 Grundfos MarineCRN-32-10 Grundfos MarineCRN-32-15 Grundfos MarineCRN-32-20 Grundfos MarineCRN-32-30 Grundfos MarineCRN-32-45 Grundfos MarineCRN-32-5 Grundfos MarineCRN-45-10 Grundfos MarineCRN-45-15 Grundfos MarineCRN-45-20 Grundfos MarineCRN-45-30 Grundfos MarineCRN-45-45 Grundfos MarineCRN-45-5 Grundfos MarineCRN-5-10 Grundfos MarineCRN-5-15 Grundfos MarineCRN-5-20 Grundfos MarineCRN-5-30 Grundfos MarineCRN-5-45 Grundfos MarineCRN-5-5 Grundfos MarineCRN-64-10 Grundfos MarineCRN-64-15 Grundfos MarineCRN-64-20 Grundfos MarineCRN-64-30 Grundfos MarineCRN-64-45 Grundfos MarineCRN-64-5 Grundfos MarineCRN-90-10 Grundfos MarineCRN-90-15 Grundfos MarineCRN-90-20 Grundfos MarineCRN-90-30 Grundfos MarineCRN-90-45 Grundfos MarineCRN-90-5 KSBEtanorm-Fire 30-1000 m³/h KSBKWP 100 55.0 kW KSBKWP 150 90.0 kW KSBKWP 80 30.0 kW KSBMovitec 10/20 KSBMovitec 10/40 KSBMovitec 10/60 KSBMovitec 10/80 KSBMovitec 100/100 KSBMovitec 100/150 KSBMovitec 100/40 KSBMovitec 100/60 KSBMovitec 1000/15 KSBMovitec 1000/30 KSBMovitec 1000/50 KSBMovitec 200/100 KSBMovitec 200/30 KSBMovitec 200/60 KSBMovitec 25/100 KSBMovitec 25/25 KSBMovitec 25/50 KSBMovitec 25/80 KSBMovitec 5/20 KSBMovitec 5/40 KSBMovitec 5/60 KSBMovitec 50/120 KSBMovitec 50/30 KSBMovitec 50/50 KSBMovitec 50/80 KSBMovitec 500/20 KSBMovitec 500/40 KSBMovitec 500/80 KSBMultitec 10/20 KSBMultitec 10/40
By manufacturer

Manufacturers.

All 29 manufacturers with models of Fire Pump (Main + Emergency). Every name opens a search across the full library.

Related types

Also in Pumps.

The other equipment types in this category.

Auxiliary Cooling SW PumpBallast PumpBilge Pump (Main + Emergency)Cargo Pump (Deepwell)Centrifugal PumpFO Circulating PumpFreshwater Hydrophore PumpFuel Oil Supply/Booster PumpFuel Oil Transfer PumpGear PumpGeneral Service PumpHT/LT Cooling Water PumpJacket Water Preheater PumpLO Standby/Priming PumpMain Cooling Seawater Pump (Centrifugal)Main Lube Oil PumpProgressive Cavity PumpPumpScrew PumpSelf-Priming PumpSludge PumpSteering Gear Hydraulic PumpStern Tube LO PumpSubmersible Pump
Knowledge

What to check on a Fire Pump (Main + Emergency).

The fire pump supplies seawater under pressure to the ship's fire main, feeding hydrants, hose stations and fixed fire-fighting systems throughout the vessel. What sets this equipment apart from other engine room pumps is the redundancy requirement behind it: SOLAS calls for at least one main fire pump plus an independently powered emergency fire pump, sited in a different space so that a single fire or flood cannot take out both. The emergency pump has its own dedicated engine or motor and its own sea suction and sea chest, entirely…

What makes this type

The fire pump supplies seawater under pressure to the ship's fire main, feeding hydrants, hose stations and fixed fire-fighting systems throughout the vessel. What sets this equipment apart from other engine room pumps is the redundancy requirement behind it: SOLAS calls for at least one main fire pump plus an independently powered emergency fire pump, sited in a different space so that a single fire or flood cannot take out both. The emergency pump has its own dedicated engine or motor and its own sea suction and sea chest, entirely separate from the main pump's arrangement.

Main and emergency fire pump arrangement
Shipboard arrangement of the main fire pump in the engine room and a fully separate emergency fire pump in another compartment, both feeding the same fire main.

Main components

Pump unit

Typically a centrifugal pump, self-priming or fitted with a priming system, sized to deliver the required capacity at the pressure needed to reach the most remote hydrant on board.

Prime mover

The main fire pump is usually driven off the ship's electrical supply or directly by a diesel engine; the emergency pump has its own independent diesel engine or, on some vessels, a dedicated generator, so it works even with the main switchboard dead.

Sea suction and sea chest

A separate sea chest for the emergency pump, positioned so flooding or damage affecting the main engine room does not also disable the emergency supply.

Fire main and isolating valves

The pump discharges into a ring or branched main fitted with isolating valves, allowing a damaged section to be shut off without losing pressure to the rest of the system.

Selection / Sizing

Required capacity is set by SOLAS in relation to the vessel's cargo pump room and machinery space dimensions, expressed as a formula linking pump output to the ship's size and type rather than a flat figure. The pump must maintain a minimum pressure at the two highest or most distant hydrants running simultaneously, and the emergency pump's capacity is set as a defined percentage of the total required main pump capacity, not simply matched one-for-one.

Regulations / Class

SOLAS Chapter II-2 sets out the number, capacity, and independence requirements for fire pumps, including the location of the emergency pump outside the category of space it is meant to back up. Class surveys check pump capacity and pressure at the fire main at intervals set by the survey scheme, and the emergency pump's independent power source is specifically verified as unaffected by a black-out condition in the main machinery space.

Typical faults

  • Loss of prime on a self-priming pump — no water delivered on start, often traced to a worn priming device or air leak in the suction line.
  • Emergency pump's dedicated engine not run-tested regularly — fails to start when actually needed after months of inactivity.
  • Fire main isolating valves seized shut or open — a damaged section cannot be isolated, dropping pressure ship-wide.
  • Sea chest strainer fouling — reduced flow and cavitation at the pump, masked until full capacity is demanded.

What to look for in a supplier

  • Certified capacity and pressure curves matching the vessel's SOLAS-required figures, not generic pump data.
  • Confirmed independence of the emergency unit's power source from the main switchboard.
  • Materials suited to continuous seawater service, since this pump must start reliably after long idle periods.

Run the emergency fire pump under load on its own weekly test, not just a no-load start; a pump that starts but cannot build pressure will pass a casual check and fail the day it matters.

Fire pump
Fire pump. Photo: Toddastephens at English Wikipedia, CC BY 2.5, via Wikimedia Commons
Search by manufacturer AFRISOWISKASwagelokAlfa Laval S.p.A.MAN Energy SolutionsWärtsiläEndress+HauserABB MarineAlfa LavalMacGregorNovenco MarineCarrier MarineSiemens MarineHeinen & HopmanDaikin Marine
Would you like to know more?

One request. A person answers within 24 hours on working days.

Tell us the manufacturer, the model and what you need — a part, a service call, a second opinion. Our desk asks the right suppliers from a network of over 114,000 companies and comes back with a quote or a sourcing plan, not a search page.

Frequently asked

Three things people ask first.

Is Fire Pump (Main + Emergency) data free?

Yes. Every model page, every guide and every datasheet for this type is readable without an account. An account adds saved searches and requests, nothing is taken away.

My model is missing — what now?

Send us the nameplate. We identify it by hand, add it to the library, and if you need a part or a service, the request is already on our desk.

Can you source a Fire Pump (Main + Emergency) part?

Yes. Tell us the manufacturer, the model and what you need — our desk asks the right suppliers from a network of over 114,000 companies and comes back with a quote or a sourcing plan.