Skip to content
OceanSphereENGINES
Library› HVAC› Galley & Domestic› Refrigerator / Freezer
Galley & Domestic

Refrigerator / Freezer

A provision refrigerator or freezer runs a sealed vapour-compression circuit against an insulated store room, holding chill and freeze bands separately for months at sea under tropical ambient and constant vibration, a duty far heavier than any domestic fridge is built for.

SEIMI
Knowledge

What to check on a Refrigerator / Freezer.

7 models from SEIMI in Refrigerator / Freezer. Below: the full model list.

What defines this type

A provision refrigerator or freezer is a self-contained vapour-compression cooling box built into the ship's provision store, distinct from a reefer container or an air-conditioning plant in that it runs a sealed refrigerant circuit against a fixed insulated room rather than a cargo box or an air duct system. It holds two temperature bands separately: chill rooms around +2 to +8 degrees C for fresh produce, dairy and meat awaiting use, and freeze rooms at -18 to -20 degrees C for long-term stores. The compressor runs near-continuously in tropical trades, cycling on thermostat or pressure control rather than the short intermittent runs typical of a domestic fridge.

Provision refrigerator and freezer circuit
Cross-section of an insulated provision cabinet with separate freezer and chill compartments, each with its own evaporator coil, connected through an expansion valve to the compressor and condenser of the vapour-compression circuit.

Legend

  1. insulated cabinet wall
  2. freezer evaporator
  3. freezer compartment
  4. condenser
  5. expansion valve
  6. chill compartment
  7. chill evaporator
  8. compressor

Main components

Compressor

Usually a semi-hermetic reciprocating or scroll compressor mounted in the compressor room, sized for the worst-case ambient the vessel will trade in, not the average. Semi-hermetic units allow valve plate and piston service without removing the whole machine.

Condenser

Air-cooled or seawater-cooled shell-and-tube condenser that rejects heat picked up in the evaporator plus the compressor's work of compression. Air-cooled units are simpler but foul quickly with salt air; seawater-cooled units need a dedicated cooling water pump and strainer.

Read the full guide

Evaporator and expansion device

Finned-coil evaporators inside the chill and freeze rooms, fed by a thermostatic expansion valve or, on smaller plants, a fixed capillary tube. A defrost heater or hot-gas defrost line clears ice buildup on a timer or demand cycle.

Room structure

Insulated sandwich panels, typically polyurethane core, with a vapour barrier to stop moisture migration into the insulation, plus heated door frames on freezer doors to stop gasket icing.

Selection and sizing

Sizing is driven by store room volume, design ambient temperature, door opening frequency and crew number, not by a generic capacity chart. Key figures a buyer checks:

  • Room volume in cubic metres against expected provisioning interval between ports
  • Refrigerant type, now typically R404A being phased down, R452A or R290 on newer installations
  • Compressor duty cycle rating for continuous tropical ambient, not intermittent domestic duty
  • Number and size of doors, since each opening is a heat load event
  • Insulation panel thickness against the target temperature band

Regulations and class

The Maritime Labour Convention 2006 requires separate, adequately sized chill and freeze provision stores for the crew complement, which sets the baseline the plant is sized against. Refrigerant choice is constrained by the Montreal Protocol and its Kigali Amendment phasing down high-GWP HFCs, so replacement refrigerant availability is a real operating concern over a ship's life. Class societies survey the provision refrigeration plant on the same periodic survey cycle as other auxiliary machinery, checking pressure vessel condition, safety valve function and refrigerant containment; there is no cargo-refrigeration-style continuous survey requirement for provision plants.

Typical faults

FaultCauseConsequence
Slow loss of cooling capacityRefrigerant leak at a flare joint or shaft sealRoom temperature creeps up unnoticed until stores spoil
High head pressure tripCondenser fouled with salt deposit or airflow blockedCompressor cuts out repeatedly, room warms during each stop
Iced-over evaporator coilFailed defrost heater or timerAirflow blocked, room temperature rises despite compressor running
Door gasket perishedAge, or freezer door heater failureFrost buildup around the frame and higher energy use to hold temperature

What to look for in a supplier

  • Refrigerant compatible with current and near-future Montreal Protocol schedules
  • Semi-hermetic or fully serviceable compressor rather than a sealed domestic-grade unit
  • Panel and door hardware rated for marine salt exposure, not shore cold-store hardware
  • Spare parts and refrigerant availability through a network the vessel's trading pattern actually reaches
  • Documented capacity calculation for the specific room volume and ambient design condition

A provision plant that trips on high head pressure in port and runs fine at sea is telling you the condenser is fouled, not that the compressor is failing, so clean it before condemning parts.

Models

Models in this type.

The best-documented model of each manufacturer first, then the next — 7 of 7 models in Refrigerator / Freezer. Every row links to full specifications, documents and service notes.

Showing only SEIMI. Show all manufacturers
7 models
By manufacturer

Manufacturers.

All 10 manufacturers with models of Refrigerator / Freezer. Names with a manufacturer page open it; the others open a search across the full library.

All manufacturers in the library
More than the data sheet shows

Write to us about this model — the answer comes by e-mail.

Name the make and the model and what the job is: a spare, a service call, a second opinion on a data sheet. We answer by e-mail.

No details at hand? A photo of the rating plate or the part is enough — simply attach it to the request.

Frequently asked

Questions that come up with this equipment.

Is Refrigerator / Freezer data free?

Yes. Every model page, every guide and every datasheet for this type is readable without an account. An account adds saved searches and requests, nothing is taken away.

My model is missing — what now?

Send us the nameplate. We identify it by hand, add it to the library, and if you need a part or a service, the request is already on our desk.

Can you source a Refrigerator / Freezer part?

Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.