A plate heat exchanger stacks thin corrugated plates to pack far more heat transfer area into a given footprint than a shell-and-tube unit of the same duty, at the cost of being far more sensitive to gasket condition and fouling between the narrow plate gaps.

50models
Kelvion
Knowledge

What to check on a Plate Heat Exchanger.

50 models from Kelvion in Plate Heat Exchanger. Below: the full model list.

What sets a plate heat exchanger apart

A plate heat exchanger builds its heat transfer surface from a stack of thin, corrugated metal plates clamped together (gasketed type) or permanently bonded (brazed or fully welded type), with hot and cold fluid running in alternating narrow channels between them. Compared with a shell-and-tube exchanger of the same duty, the plate design packs several times more surface area into the same volume because the corrugation pattern creates turbulence at low flow velocity, which improves heat transfer without needing long tube runs. The trade-off is channel width: gaps between plates are typically only a few millimetres, so the design is far less tolerant of solids, scale or fibrous debris than a tube bundle, and a gasketed unit depends entirely on gasket condition to stay leak-tight between the plate pack and between the fluid circuits.

Plate heat exchanger, plate pack arrangement
Cutaway of a gasketed plate heat exchanger: the fixed frame plate carries the four ports, the pack of corrugated plates is clamped by tie bolts against the movable pressure plate, gaskets seal each channel, and hot and cold fluid run in counter-flow through alternate channels.

Legend

  1. Tie bolts
  2. Plate pack (corrugated plates)
  3. Gasket (channel seal)
  4. Hot fluid in
  5. Cold fluid out
  6. Pressure plate (movable)
  7. Cold fluid in
  8. Hot fluid out
  9. Frame plate (fixed)
  10. Counter-flow channels

Main components

Plate pack

Pressed stainless steel or titanium plates with a herringbone or chevron corrugation pattern that sets the flow path and turbulence level; plate thickness and corrugation depth are chosen for the pressure and duty.

Gaskets (gasketed type)

Elastomer gaskets, glued or clip-fitted into a groove around each plate, seal the fluid channels and route flow between ports. Gasket material (NBR, EPDM, Viton) is selected for the fluid and temperature; the wrong gasket compound in a fuel or lube oil circuit degrades quickly.

Read the full guide

Frame, carrying bar and tightening bolts

The frame clamps the plate pack to a specified compressed thickness; under-tightening lets gaskets leak, over-tightening deforms plates and shortens gasket life.

Brazed or welded pack (compact type)

Copper-brazed or fully welded plate packs eliminate gaskets entirely, giving a smaller, higher-pressure-rated unit that cannot be opened for mechanical cleaning, only backflushed or chemically cleaned.

Selection and sizing

  • Duty and approach temperature - the closer the required approach temperature between the two fluids, the more plates or the larger the area needed.
  • Pressure rating - gasketed units typically handle up to around 25 bar; brazed and welded types reach substantially higher.
  • Fouling tendency of the fluid - seawater cooling duty favours a gasketed, openable design for periodic mechanical cleaning; clean closed-loop duty suits brazed units.
  • Materials - titanium plates for raw seawater service resist chloride pitting far better than stainless steel.
  • Connection size and plate count - determines physical footprint against available engine room space.

Regulations and class

Plate heat exchangers used in essential services (main engine cooling, fuel heating for combustion) fall under the class society's pressure vessel and piping rules for design pressure, material certification and pressure testing before delivery. Where the exchanger separates a fuel or lube system from a cooling water system, class rules typically require the design to prevent internal cross-contamination or to allow leak detection between circuits, since a failed plate or gasket can let fuel into cooling water or vice versa. There is no IMO convention specific to the plate exchanger type itself; requirements come through the classification society's machinery rules for the system the exchanger is part of.

Typical faults

FaultConsequence
Gasket hardening or shrinkage with ageinter-plate leakage, cross-contamination between fluid circuits
Fouling/scaling in narrow channelsrising pressure drop and falling heat transfer, often mistaken for pump wear
Plate corrosion pitting (wrong material for seawater)through-wall leaks, seawater ingress into the clean circuit
Incorrect re-assembly after opening for cleaningplates out of sequence change the flow path and duty is lost even though the unit looks intact

What to look for in a supplier

  • Material certificates for plates matching the actual fluid, especially titanium confirmation for seawater duty.
  • Gasket compound datasheet matching the fluid and maximum operating temperature, not a generic default.
  • Availability of individual replacement plates and gaskets for the exact plate pattern, since plate packs are not interchangeable between makers.

Before reassembling a gasketed plate exchanger after cleaning, check the plates go back in the original sequence and orientation - a swapped plate changes the flow pattern and the unit can look assembled correctly while badly underperforming.

Models

Models in this type.

The best-documented model of each manufacturer first, then the next — 50 of 50 models in Plate Heat Exchanger. Every row links to full specifications, documents and service notes.

Showing only Kelvion. Show all manufacturers
KelvionGX 12 3 m² surface KelvionGX 26 10 m² surface KelvionGX 42 20 m² surface KelvionNX 100L 30 m² surface KelvionNX 250L 60 m² surface KelvionNX 25M 5 m² surface KelvionNX 50M 15 m² surface KelvionGML 400H/GML 500H KelvionK 070 100kW LO cooling KelvionK 070 200kW LO cooling KelvionK 070 50kW LO cooling KelvionK 070 Series KelvionNX 100 1000kW Central cooling KelvionNX 100 2000kW Central cooling KelvionNX 100 200kW Central cooling KelvionNX 100 500kW Central cooling KelvionNX 100 Series KelvionNX 150 1000kW Central cooling KelvionNX 150 1000kW Jacket water cooling KelvionNX 150 2000kW Central cooling KelvionNX 150 2000kW Jacket water cooling KelvionNX 150 3000kW Central cooling KelvionNX 150 3000kW Jacket water cooling KelvionNX 150 500kW Central cooling KelvionNX 150 500kW Jacket water cooling KelvionNX 150 Series KelvionNX 25 100kW FW cooling KelvionNX 25 100kW LO cooling KelvionNX 25 200kW FW cooling KelvionNX 25 200kW LO cooling KelvionNX 25 500kW FW cooling KelvionNX 25 500kW LO cooling KelvionNX 25 50kW FW cooling KelvionNX 25 50kW LO cooling KelvionNX 25 Series KelvionNX 250 1000kW Central cooling KelvionNX 250 2000kW Central cooling KelvionNX 250 3000kW Central cooling KelvionNX 250 5000kW Central cooling KelvionNX 250 Series KelvionNX 50 1000kW Central cooling KelvionNX 50 1000kW LO cooling KelvionNX 50 100kW Central cooling KelvionNX 50 100kW LO cooling KelvionNX 50 200kW Central cooling KelvionNX 50 200kW LO cooling KelvionNX 50 500kW Central cooling KelvionNX 50 500kW LO cooling KelvionNX 50 Series KelvionK°Flex
Would you like to know more?

One request. A person reads it and replies by e-mail.

Tell us the manufacturer, the model and what you need — a part, a service call, a second opinion. A person reads every request and replies by e-mail.

No details at hand? A photo of the rating plate or the part is enough — simply attach it to the request.

Frequently asked

Three things people ask first.

Is Plate Heat Exchanger data free?

Yes. Every model page, every guide and every datasheet for this type is readable without an account. An account adds saved searches and requests, nothing is taken away.

My model is missing — what now?

Send us the nameplate. We identify it by hand, add it to the library, and if you need a part or a service, the request is already on our desk.

Can you source a Plate Heat Exchanger part?

Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.