Kelvion Kelvion GX 26 — Heat Exchangers, high-pressure. The supplied category identifies the equipment as Plate Heat Exchanger, and it is normally installed in an engine-room cooling, heating, condensing or heat-recovery circuit according to the vessel piping arrangement. In that listed role, its primary purpose is to transfer heat between two fluid streams while keeping the media separated. Plate, shell-and-tube, condenser and evaporator designs differ in construction and cleaning method, so the model-specific material and pressure limits must come from its documentation. The model designation identifies the listed configuration, but no additional performance, approval or construction detail is inferred from the model code beyond the information supplied in the source record. The source metadata also states capacity: 10 m² surface. For exact ratings, dimensions, settings, capacities, materials and variant-specific limits, refer to the manufacturer documentation for the exact figure.

10 m² surface
Capacity

Components & Design

Component data being added…

Technical Data

exchanger type plate
surface area m2 10
max pressure bar 30

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Fouling or scaling increases differential pressure and reduces heat-transfer performance
Gasket, seal or tube-joint deterioration causes external leakage
Plate or tube corrosion, erosion or cracking causes internal cross-contamination between fluid circuits
Blocked strainers or restricted valves reduce flow and produce abnormal inlet-to-outlet temperatures
Incorrect reassembly, venting or flow distribution after service causes leakage or poor thermal performance

Service & Maintenance

Trend inlet and outlet temperatures and differential pressure and inspect for leakage. Open or clean the exchanger only by the approved method and examine plates, tubes, gaskets or end covers for deposits, corrosion and deformation. Investigate any cross-contamination promptly. Refer to the manufacturer documentation for the exact figure for tightening, test pressure and wear limits.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Carry the correct gaskets or seals, representative plates or tube-repair provisions where approved, port seals, strainers and compatible cleaning materials.
Equipment Model #67865 · ✓ still in production