Cargo Tank Heating System
Cargo tank heating exists to keep viscous or wax-bearing cargo pumpable, not to raise the whole tank to one temperature - most systems heat the coils and let convection do the rest, so a badly loaded tank can show good coil temperatures and still discharge slowly.
What to check on a Cargo Tank Heating System.
14 models from Alfa Laval in Cargo Tank Heating System. Below: the full model list.
What a cargo tank heating system does
Some cargoes - heavy fuel oil, bitumen, certain vegetable oils, and waxy crude fractions - become too viscous to pump at ambient sea temperature. A cargo tank heating system keeps the cargo warm enough to discharge within the time and pump-pressure limits of the vessel, without overheating it to the point of degrading quality or, on some cargoes, creating a fire or reaction risk. This is a separate function from tank cleaning heating and from cargo temperature control on gas carriers, though the coil hardware can look similar.
Main components
- Heating coils - steel or, on cargoes sensitive to contamination, stainless coils laid across the tank bottom, connected to the thermal fluid supply and return.
- Thermal fluid boiler or heater - typically a thermal oil heater rather than direct steam, giving higher temperatures at lower system pressure than a steam plant of comparable size.
- Circulation pumps - move the heating medium through the coil network; often duplicated so one tank's demand does not starve another.
- Temperature sensors and control valves - modulate flow to individual tank coils to hold a setpoint rather than run every coil at maximum continuously.
Selection and sizing
Coil area and thermal fluid flow are sized against the cargo's viscosity curve, the discharge temperature the cargo needs to reach, the ambient sea and air temperature on the trade route, and the discharge time window the charter requires. A system undersized for its trade will still show a rising tank temperature on the gauge while the cargo near the tank top, away from the coils, stays cold and slow to pump.
Regulations and class
MARPOL Annex I and Annex II set discharge and cargo handling requirements relevant to residues and slops that heating affects, and class rules cover the thermal fluid system's pressure vessel and piping certification the same as any other pressurised system on board. For cargoes with a flash point close to the required heating temperature, the tanker's cargo system operating manual sets a maximum heating temperature with a safety margin below flash point, and this figure is checked at survey against the actual coil setpoints in use.
Read the full guide
Typical faults
- Coil leaks contaminating cargo - a cracked coil lets thermal fluid into the cargo or, worse, cargo into the thermal fluid system, showing up as an unexplained system pressure or level change.
- Localised overheating near coils - cargo directly against the coil surface can exceed the bulk setpoint significantly, degrading heat-sensitive cargoes even while the bulk reading looks correct.
- Fouled coils losing heat transfer efficiency - wax or sediment buildup on the coil surface over successive voyages, requiring longer heating times for the same result.
- Thermal fluid degradation - oxidation of the heating medium over years of service raises its viscosity and lowers heat transfer, often missed until a scheduled fluid analysis flags it.
What to look for in a supplier
- Coil design and material matched to the cargo range the vessel actually trades, not a generic heavy-fuel default.
- Thermal fluid heater capacity documented against the vessel's full tank heating load, not a single-tank test case.
- Support for thermal fluid condition monitoring and replacement scheduling.
- Clear coil leak-detection method built into the system design, since a slow coil leak is otherwise hard to catch early.
Read tank temperature from more than one point before trusting a coil-side sensor - the cargo furthest from the coils is the cargo that decides whether discharge finishes on time.
Models in this type.
The best-documented model of each manufacturer first, then the next — 14 of 14 models in Cargo Tank Heating System. Every row links to full specifications, documents and service notes.
Manufacturers.
All 7 manufacturers with models of Cargo Tank Heating System. Names with a manufacturer page open it; the others open a search across the full library.
All manufacturersAlso in Tanker Cargo Systems.
The other equipment types in this category.
One request. A person reads it and replies by e-mail.
Tell us the manufacturer, the model and what you need — a part, a service call, a second opinion. A person reads every request and replies by e-mail.
No details at hand? A photo of the rating plate or the part is enough — simply attach it to the request.
Three things people ask first.
Is Cargo Tank Heating System data free?
Yes. Every model page, every guide and every datasheet for this type is readable without an account. An account adds saved searches and requests, nothing is taken away.
My model is missing — what now?
Send us the nameplate. We identify it by hand, add it to the library, and if you need a part or a service, the request is already on our desk.
Can you source a Cargo Tank Heating System part?
Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.