Skip to content
OceanSphereENGINES
Library› Engine Room› Auxiliary Engines› Auxiliary Engine (Generator Set)
Auxiliary Engines

Auxiliary Engine (Generator Set)

An auxiliary engine is a diesel genset built to run at constant speed for frequency-stable electrical output, not to drive a propeller — a distinction that shapes its governor, cooling, and load-acceptance design from the ground up.

88manufacturers
48–7,360 kWtypical power
9 Nov 2026last updated
Knowledge

What to check on an Auxiliary Engine (Generator Set).

2,647 models from 88 manufacturers. Below: the manufacturers at a glance and the full model list.

What makes this type

An auxiliary engine (generator diesel engine, or "aux") is coupled directly to an alternator and runs at a fixed synchronous speed — typically 1200, 1500, or 1800 rpm depending on frequency (50 or 60 Hz) and pole count — because the alternator's output frequency is locked to shaft speed. This is the core difference from a main propulsion engine, which is allowed to vary speed continuously with load. An aux engine's governor is tuned for tight speed regulation under sudden load steps, since connecting or dropping a large consumer (a cargo pump starting, a bow thruster engaging) has to be absorbed within a few percent of frequency deviation without tripping protective relays or blacking out the switchboard. Auxiliary engines usually run in multiples — two to four sets per ship — specifically so load can be shared and units can be swapped out for maintenance without losing power generation capability.

Marine auxiliary generator set
Marine auxiliary generator set on a common bedplate: the diesel engine drives the alternator through a flexible coupling, with the engine cooler above the engine, the exhaust outlet from the cylinder head, the control and terminal box on the alternator and resilient mounts under the bedplate.

Legend

  1. Engine cooler
  2. Exhaust outlet
  3. Cooling water to and from the engine
  4. Control and terminal box
  5. Diesel engine
  6. Alternator
  7. Flexible coupling
  8. Common bedplate
  9. Resilient mounts

Main components

Engine block and fuel injection

Most modern aux engines are medium- or high-speed four-stroke trunk-piston diesels, mechanically or electronically fuel injected; electronic (common-rail or unit-injector) control has become common because it improves transient load response, which matters more for a genset than a main engine.

Governor and AVR

The governor holds engine speed (hence frequency) constant; the alternator's automatic voltage regulator holds terminal voltage constant. Both must respond fast enough that a step load change does not push frequency or voltage outside the narrow band the switchboard protection allows.

Read the full guide

Alternator

Directly coupled, sized in kVA with a power factor rating (commonly 0.8) that determines real kW output versus apparent power capacity.

Cooling and lube oil systems

Sized for continuous duty at rated load, since unlike a main engine that may run at reduced load for long passages, gensets are commonly loaded close to their rating whenever running to keep specific fuel consumption reasonable.

Selection / Sizing

Sizing starts from the ship's electrical load list at different operating conditions (at sea, in port, cargo operations, manoeuvring) and picks a genset combination that covers peak load with one unit out of service (N+1 redundancy is standard practice, and mandatory in some class notations). Running gensets well below rated load for long periods causes its own problems — incomplete combustion, cylinder glazing, exhaust valve fouling — so the number and size of units is chosen to keep each running set reasonably loaded across the ship's typical load profile, rather than fitting one oversized set that is always lightly loaded.

Regulations / Class

Class rules require a minimum number of generating sets such that with the largest set out of service, the remainder can supply all services needed for propulsion, steering, and safety. MARPOL Annex VI NOx Tier limits apply based on engine build date and size, same as main engines, and an Engine International Air Pollution Prevention (EIAPP) certificate is required per engine. SOLAS requires an emergency source of power separate from the main gensets, which is a different piece of equipment entirely (see Emergency Generator Sets).

Typical faults

  • Cylinder liner glazing from prolonged light-load running — poor ring seating leads to rising lube oil consumption and blow-by.
  • Governor hunting — speed oscillation under load, often from worn linkage or actuator issues, that causes frequency instability across the switchboard.
  • Turbocharger fouling — reduced air supply under load, showing up as high exhaust temperature and falling power output at rated load.
  • Injector wear affecting load sharing — uneven fuel delivery between cylinders shows up as vibration and uneven exhaust temperatures across units.
  • AVR drift — slow voltage regulation that causes reactive load-sharing problems when running gensets in parallel.

What to look for in a supplier

  • NOx certification (EIAPP) matched to the intended trading area and build date, since retrofitting Tier III compliance later is costly.
  • Genset packages tested together (engine, alternator, governor, AVR) rather than components sourced separately and matched on paper.
  • Parts and service network reach in the ship's actual trading pattern, not just the flag state.
  • Documented load-acceptance figures (percentage step load the set can absorb without exceeding frequency/voltage transient limits) for the specific application.

A genset that never gets loaded above 40% for weeks at a time is quietly glazing its liners — rotate load between units and run one hard periodically rather than always splitting load evenly and lightly.

Models

Models in this type.

The best-documented model of each manufacturer first, then the next — 100 of 2,647 models in Auxiliary Engine (Generator Set). Every row links to full specifications, documents and service notes.

Page 1 of 27 · Next →
Caterpillar Marine12V3512B Gen 1,080 kW MAN Energy Solutions10L21/31-GS-50Hz 2,000 kW Wärtsilä12VW20-GS-50Hz 1,320 kW Volvo Penta4LD5-GS-50Hz 120 kW Scania6LDI09-GS-50Hz 300 kW MaK12VM32-GS-50Hz 5,280 kW Cummins12VKTA38-G-50Hz 1,260 kW John Deere Power Systems350HC 210 kW Perkins1104D-E44TAG Marine Generator Engine 80 kW Daihatsu12VDK-36e-GS-50Hz 7,080 kW Hanshin5LEL30-GS-50Hz 1,650 kW MTU10V10V2000-GS-50Hz 750 kW Yanmar3JH40, 4JH45 and 4JH57 Baudouin12V12M33.2-GS-50Hz 4,320 kW Deutz12VBV12M628-GS-50Hz 1,560 kW Rolls-Royce / Bergen12VB32:40-GS-50Hz 5,280 kW Weichai12VCW12V250-GS-50Hz 2,100 kW HiMSEN12VH32/40-GS-50Hz 5,280 kW Doosan12VAD222TI-G-50Hz 624 kW FG Wilson16VP-Series 800 800 kW HimoinsaHMW-100-50Hz SDMOT12K-50Hz Northern Lights1066A 147 kW Mitsubishi12VS12A2-MPTK-50Hz 1,104 kW PramacGSW1100M-50Hz ABC3DX 883 kW Kohler125EKOF-50Hz MAN Generator5-L16/24 GenSet 550 kW IHI Agri-TechGH3XN.761E3C 10 kW John Deere4L4045AFM-GS-50Hz 104 kW Akasaka DieselA45S 3,309 kW Fischer PandaAGT-DC 100000-50Hz OnanMDKAV-50Hz Sole DieselSM-105-50Hz MTU Onsite EnergySeries 1163 G-12cyl 3,480 kW FPT IndustrialC16 600 CSSC/Hudong12VMAN16/24H-GS-50Hz 1,416 kW Niigata12V12V32HX-GS-50Hz 5,640 kW SKL12VNVD48-GS-50Hz 8,160 kW GeneracMDG005-50Hz MastervoltWhisper 10-50Hz Doosan Infracore Marine4AD158TI Detroit DieselSERIES 60 Mitsubishi Heavy Industries Engine & TurbochargerMAS 1350 1,056 kW Mitsubishi Heavy IndustriesL-MA2 9 kW Discovery EnergyKDI 2504TCR 49 kW Pielstick12VPA6B-GS-50Hz 3,120 kW STX EngineL21 20 90 D2 LN 1,800 kW Caterpillar Motoren, Kiel, GermanyM 20 1,800 kW Daihatsu Diesel Aux12-DC32 Gen 6,360 kW Bergen EnginesB32:40L 3,840 kW Cummins Power Generation12VVTA28-G 840 kW Vestbork Diesel ApSVBD 12V-28 2,940 kW Wabtec Transportation SystemsXL250Y 2,230 kW Yanmar Power Technology6EY26LW 1,840 kW Legacy MarinedieselTAMD31L Perkins Marine Aux16V4006 G 1,760 kW Progress Rail Locomotive645E7B 2,953 kW Volvo Penta Power6-D11A MG 360 kW Fairbanks Morse EngineFM-OP 3,132 kW Caterpillar Marine PowerC18 Aux Alaska diesel electricL944 51 kW Beta MarineBETA50CMA 36 kW Electro-Motive Diesel645E7B, F7B 2,985 kW Engines6090HFI 262 kW HD Hyundai InfracoreDL08C 280 kW HSD Engine28/32DFA 1,836 kW Hyundai Heavy Industries9H27DF-2015-01 2,565 kW Kennedy EngineKEC6135AG 367 kW Rolls-Royce Solutions AmericaSERIES 1600 MARINE 355 kW AdriadieselL23/30H 1,280 kW Doosan Power6V6V158TIH 300 kW John Deere Marine Aux6L6135AFM G 450 kW Mase GeneratorsIS 12 Marine Diesel Generator 10 kW Transp. systems bus. opS. of general electricXL250Y 2,330 kW Tognum AmericaSeries 2000 1,492 kW Zhenjiang CmeL28/32H 1,890 kW Cummins Mercruiser dieselMOG18QTA GuascorG-56SL Mecc AlteHSY-10 M5 SOLESolé Diesel / MIDIF STEYR MOTORS BetriebsM16TCAM WesterbekeFour-107 Caterpillar Marine12V3512E Gen 1,560 kW MAN Energy Solutions10L21/31-GS-60Hz 2,000 kW Wärtsilä12VW20-GS-60Hz 1,320 kW Volvo Penta4LD5-GS-60Hz 120 kW Scania6LDI09-GS-60Hz 300 kW MaK12VM32-GS-60Hz 5,280 kW Cummins12VKTA38-G-60Hz 1,260 kW John Deere Power Systems350MAA 246 kW Perkins1106D-E70TAG Marine Generator Engine 150 kW Daihatsu12VDK-36e-GS-60Hz 7,080 kW Hanshin5LEL30-GS-60Hz 1,650 kW MTU10V10V2000-GS-60Hz 750 kW Yanmar4JH80 and 4JH110 Baudouin12V12M33.2-GS-60Hz 4,320 kW Deutz12VBV12M628-GS-60Hz 1,560 kW Rolls-Royce / Bergen12VB32:40-GS-60Hz 5,280 kW Weichai12VCW12V250-GS-60Hz 2,100 kW
By manufacturer

Manufacturers.

All 88 manufacturers with models of Auxiliary Engine (Generator Set). Names with a manufacturer page open it; the others open a search across the full library.

All manufacturers in the library
Show all 88 manufacturers
Related types

Also in Auxiliary Engines.

The other equipment types in this category.

Auxiliary EngineLifeboat EngineMarine Fuel Cell System
More than the data sheet shows

Write to us about this model — the answer comes by e-mail.

Name the make and the model and what the job is: a spare, a service call, a second opinion on a data sheet. We answer by e-mail.

No details at hand? A photo of the rating plate or the part is enough — simply attach it to the request.

Frequently asked

Questions that come up with this equipment.

Is Auxiliary Engine (Generator Set) data free?

Yes. Every model page, every guide and every datasheet for this type is readable without an account. An account adds saved searches and requests, nothing is taken away.

My model is missing — what now?

Send us the nameplate. We identify it by hand, add it to the library, and if you need a part or a service, the request is already on our desk.

Can you source a Auxiliary Engine (Generator Set) part?

Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.