ABC (Anglo Belgian Corporation)

3DX

ABC (Anglo Belgian Corporation) 3DX — Marine propulsion, auxiliary power.

Components & Design

Component data being added…

Technical Data

Configuration 3-cylinder inline
Bore x Stroke 242 x 320 mm
Max Power 138 kW @ 600 rpm (naturally aspirated)
Cycle 4-stroke
Compression Ratio 12.45:1

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Bore and stroke verification - DX series uses 242x320mm while DZ/DZC series use 256x310mm and DL/DV36 series use 365x420mm. Critical for engine identification a

Verify bore/stroke dimensions against engine nameplate and verify correct engine series is installed (DX vs DZ vs DL36 series are not interchangeable).

Medium-speed engines (600-1000 rpm) vs higher-speed Evolve series (up to 1200 rpm) - different fuel consumption rates and maintenance schedules. SFOC for medium

Confirm actual engine speed rating at nameplate and service manual fuel consumption specifications. Verify maintenance interval alignment with actual engine speed class.

Emissions compliance variants - DL36/DV36 (2019+) and Evolve EL23/EV23 series are IMO Tier III compliant with EGR/SCR aftertreatment. Older DZ/DZC/DX models may

Verify actual emissions tier on nameplate, check EGR/SCR/DPF system installation and maintenance history, confirm fuel type matches engine certification (HFO capable engines vs distillate-only).

Fuel type compatibility critical - older DX/DZ engines can run on HFO but Evolve EL23 series specify (bio)diesel/HVO only as primary fuel. Incorrect fuel type w

Confirm fuel type in use matches engine certification. Check fuel treatment system (separators, filters). Verify fuel supply specification with technical datasheet for specific engine model.

Turbocharging configuration - DZ/DZC single-stage turbo vs DL36/DV36/Evolve with two-stage turbocharging. Two-stage systems require more frequent intercooler ma

Verify turbocharger stage configuration and boost pressure settings on test gauge. Check intercooler cooling efficiency and charge air cooler condition. Review turbo service history and bearing clearance measurements.

Type-general inspection and maintenance points for this equipment category — not model-specific.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →
Equipment Model #149641 · ✓ still in production