0.6/1 kV marks the cable's voltage class - 0.6 kV phase to earth, 1 kV phase to phase - covering most of a ship's power distribution below the switchboard, distinct from control cable rated for signal duty and from medium-voltage cable used on larger vessels.

216models
Eland Cables
Knowledge

What to check on a Power Cable (0.6/1 kV).

216 models from Eland Cables in Power Cable (0.6/1 kV). Below: the full model list.

What the 0.6/1 kV rating means

The two figures describe the cable's rated voltage: 0.6 kV between a conductor and earth, 1 kV between two conductors, which is the standard low-voltage class covering most power distribution aboard ship, meaning feeders from the switchboard to motors, pumps, lighting distribution boards and general service loads. It sits below medium-voltage cable, rated at several kilovolts and used only where the ship's own generation and distribution runs at higher voltage, and above the lighter control and instrumentation cable that carries signals rather than load current. Choosing this class wrongly in either direction either wastes copper on an oversized cable or, worse, puts an undersized cable into a circuit it cannot carry safely.

Marine power cable cross-section
Cross-section of a three-core 0.6/1 kV marine power cable: stranded copper conductors with their own insulation, laid up and covered by a bedding, steel wire armour over the bedding and an outer sheath as the final jacket.

Legend

  1. Armour (galvanised steel wire)
  2. Outer sheath (jacket)
  3. Bedding
  4. Insulation (per core)
  5. Conductor (stranded copper)
  6. Laid-up cores with fillers

Main components

Conductor

Stranded copper, sized by cross-sectional area to the circuit's current rating; stranding rather than solid conductor is standard for the flexibility a ship's cable routes demand.

Insulation

Cross-linked polyethylene, XLPE, or ethylene propylene rubber, EPR, is typical, chosen for its temperature rating and resistance to the moisture and oil a ship's cable runs are exposed to.

Read the full guide

Bedding and armour

An inner bedding layer separates the insulated cores from a steel wire braid or tape armour, which gives the cable mechanical protection and, earthed correctly, a return path for fault current.

Outer sheath

Marine cable sheathing is specified for low smoke and zero halogen performance so that, in a fire, it does not add toxic or corrosive smoke to spaces that may already be hard to evacuate.

Selection and sizing

Current-carrying capacity, derated for the number of cables run together in a bundle and for the ambient temperature of the space they pass through, sets the minimum cross-section. Voltage drop over the run length is checked separately, since a cable that is rated for the current can still be too small if the run is long enough to drop voltage below what the load needs at start-up.

  • Cross-sectional area sized to derated current capacity, not the nameplate rating alone
  • Number of cores and whether a separate earth core or the armour itself provides the earth return
  • Armour type suited to the routing, since exposed deck runs need more mechanical protection than a protected trunk
  • Fire performance class matching the space: flame-retardant as standard, fire-resistant where the circuit must keep working during a fire, such as emergency lighting or fire pumps

Regulations and class

Marine power cable construction and testing follows the IEC 60092 series, which covers conductor sizing, insulation and sheath materials and fire performance for shipboard use. SOLAS Chapter II-2 requires that cable routed through machinery spaces and other fire risk areas meet flame-retardant standards as a minimum, with fire-resistant cable required for circuits that must stay live during a fire, such as emergency power, fire pumps and emergency lighting. Class societies check routing and segregation as part of the electrical survey, since running the main and emergency feed for the same system through one trunk defeats the redundancy the rules are meant to provide.

Typical faults

CauseConsequence
Insulation degradation from heat or oil exposure over timeFalling insulation resistance, eventual earth fault
Armour damage from chafe against structureLoss of mechanical protection and possible earth continuity fault
Overloading a cable run bundled with too many othersOverheating from unaccounted-for derating, accelerated insulation ageing
Poor gland termination at bulkhead penetrationsMoisture ingress at the gland, tracking and insulation failure

What to look for in a supplier

  • Type approval to IEC 60092 with test certificates for the specific fire performance class ordered
  • Consistent core colour coding and marking that matches the ship's existing cable schedule
  • Batch traceability, since a cable fault investigation needs to trace back to a specific manufacturing lot
  • Stock of the specific armour and sheath combination the ship's routing standard calls for, not just the nearest equivalent

Check derating for bundled cable runs before assuming a cable is oversized on paper - a cable that is comfortably rated on its own can still run hot once it is one of a dozen in the same tray.

Models

Models in this type.

The best-documented model of each manufacturer first, then the next — 100 of 216 models in Power Cable (0.6/1 kV). Every row links to full specifications, documents and service notes.

Showing only Eland Cables. Show all manufacturers
Eland Cables0.6/1kV Cable Eland Cables0.6/1kV Power Cable Eland Cables2XSL(st)CH LSZH Eland Cables2XSLCHRH 0.6/1kV Cable Eland Cables2XSLCYK-J Eland CablesEN 50525-2-21 Eland CablesF17LV03035YW Eland CablesF17LV03070YW Eland CablesF19LV04035YW Eland CablesF19LV04050YW Eland CablesF19LV04070YW Eland CablesF19LV04120YW Eland CablesF21LV07070BK Eland CablesF23LV07035BK Eland CablesF23LV07050BK Eland CablesF23LV07070BK Eland CablesF25LV07035BK Eland CablesJ 0.6/1kV Eland CablesMGCH 1Cx1.5mm2 0.6/1kV Eland CablesMGCH 1Cx1.5mm2 0.6/1kV SWA Eland CablesMGCH 1Cx1.5mm2 0.6/1kV braid Eland CablesMGCH 1Cx1.5mm2 0.6/1kV unarmored Eland CablesMGCH 1Cx10mm2 0.6/1kV Eland CablesMGCH 1Cx10mm2 0.6/1kV SWA Eland CablesMGCH 1Cx10mm2 0.6/1kV braid Eland CablesMGCH 1Cx10mm2 0.6/1kV unarmored Eland CablesMGCH 1Cx120mm2 0.6/1kV Eland CablesMGCH 1Cx120mm2 0.6/1kV SWA Eland CablesMGCH 1Cx120mm2 0.6/1kV braid Eland CablesMGCH 1Cx120mm2 0.6/1kV unarmored Eland CablesMGCH 1Cx150mm2 0.6/1kV Eland CablesMGCH 1Cx150mm2 0.6/1kV SWA Eland CablesMGCH 1Cx150mm2 0.6/1kV braid Eland CablesMGCH 1Cx150mm2 0.6/1kV unarmored Eland CablesMGCH 1Cx16mm2 0.6/1kV Eland CablesMGCH 1Cx16mm2 0.6/1kV SWA Eland CablesMGCH 1Cx16mm2 0.6/1kV braid Eland CablesMGCH 1Cx16mm2 0.6/1kV unarmored Eland CablesMGCH 1Cx185mm2 0.6/1kV Eland CablesMGCH 1Cx185mm2 0.6/1kV SWA Eland CablesMGCH 1Cx185mm2 0.6/1kV braid Eland CablesMGCH 1Cx185mm2 0.6/1kV unarmored Eland CablesMGCH 1Cx2.5mm2 0.6/1kV Eland CablesMGCH 1Cx2.5mm2 0.6/1kV SWA Eland CablesMGCH 1Cx2.5mm2 0.6/1kV braid Eland CablesMGCH 1Cx2.5mm2 0.6/1kV unarmored Eland CablesMGCH 1Cx240mm2 0.6/1kV Eland CablesMGCH 1Cx240mm2 0.6/1kV SWA Eland CablesMGCH 1Cx240mm2 0.6/1kV braid Eland CablesMGCH 1Cx240mm2 0.6/1kV unarmored Eland CablesMGCH 1Cx25mm2 0.6/1kV Eland CablesMGCH 1Cx25mm2 0.6/1kV SWA Eland CablesMGCH 1Cx25mm2 0.6/1kV braid Eland CablesMGCH 1Cx25mm2 0.6/1kV unarmored Eland CablesMGCH 1Cx300mm2 0.6/1kV Eland CablesMGCH 1Cx300mm2 0.6/1kV SWA Eland CablesMGCH 1Cx300mm2 0.6/1kV braid Eland CablesMGCH 1Cx300mm2 0.6/1kV unarmored Eland CablesMGCH 1Cx35mm2 0.6/1kV Eland CablesMGCH 1Cx35mm2 0.6/1kV SWA Eland CablesMGCH 1Cx35mm2 0.6/1kV braid Eland CablesMGCH 1Cx35mm2 0.6/1kV unarmored Eland CablesMGCH 1Cx4mm2 0.6/1kV Eland CablesMGCH 1Cx4mm2 0.6/1kV SWA Eland CablesMGCH 1Cx4mm2 0.6/1kV braid Eland CablesMGCH 1Cx4mm2 0.6/1kV unarmored Eland CablesMGCH 1Cx50mm2 0.6/1kV Eland CablesMGCH 1Cx50mm2 0.6/1kV SWA Eland CablesMGCH 1Cx50mm2 0.6/1kV braid Eland CablesMGCH 1Cx50mm2 0.6/1kV unarmored Eland CablesMGCH 1Cx6mm2 0.6/1kV Eland CablesMGCH 1Cx6mm2 0.6/1kV SWA Eland CablesMGCH 1Cx6mm2 0.6/1kV braid Eland CablesMGCH 1Cx6mm2 0.6/1kV unarmored Eland CablesMGCH 1Cx70mm2 0.6/1kV Eland CablesMGCH 1Cx70mm2 0.6/1kV SWA Eland CablesMGCH 1Cx70mm2 0.6/1kV braid Eland CablesMGCH 1Cx70mm2 0.6/1kV unarmored Eland CablesMGCH 1Cx95mm2 0.6/1kV Eland CablesMGCH 1Cx95mm2 0.6/1kV SWA Eland CablesMGCH 1Cx95mm2 0.6/1kV braid Eland CablesMGCH 1Cx95mm2 0.6/1kV unarmored Eland CablesMGCH 3Cx1.5mm2 0.6/1kV Eland CablesMGCH 3Cx1.5mm2 0.6/1kV SWA Eland CablesMGCH 3Cx1.5mm2 0.6/1kV braid Eland CablesMGCH 3Cx1.5mm2 0.6/1kV unarmored Eland CablesMGCH 3Cx10mm2 0.6/1kV Eland CablesMGCH 3Cx10mm2 0.6/1kV SWA Eland CablesMGCH 3Cx10mm2 0.6/1kV braid Eland CablesMGCH 3Cx10mm2 0.6/1kV unarmored Eland CablesMGCH 3Cx120mm2 0.6/1kV Eland CablesMGCH 3Cx120mm2 0.6/1kV SWA Eland CablesMGCH 3Cx120mm2 0.6/1kV braid Eland CablesMGCH 3Cx120mm2 0.6/1kV unarmored Eland CablesMGCH 3Cx150mm2 0.6/1kV Eland CablesMGCH 3Cx150mm2 0.6/1kV SWA Eland CablesMGCH 3Cx150mm2 0.6/1kV braid Eland CablesMGCH 3Cx150mm2 0.6/1kV unarmored Eland CablesMGCH 3Cx16mm2 0.6/1kV Eland CablesMGCH 3Cx16mm2 0.6/1kV SWA
By manufacturer

Manufacturers.

All 99 manufacturers with models of Power Cable (0.6/1 kV). Names with a manufacturer page open it; the others open a search across the full library.

All manufacturers
Show all 99 manufacturers
Would you like to know more?

One request. A person reads it and replies by e-mail.

Tell us the manufacturer, the model and what you need — a part, a service call, a second opinion. A person reads every request and replies by e-mail.

No details at hand? A photo of the rating plate or the part is enough — simply attach it to the request.

Frequently asked

Three things people ask first.

Is Power Cable (0.6/1 kV) data free?

Yes. Every model page, every guide and every datasheet for this type is readable without an account. An account adds saved searches and requests, nothing is taken away.

My model is missing — what now?

Send us the nameplate. We identify it by hand, add it to the library, and if you need a part or a service, the request is already on our desk.

Can you source a Power Cable (0.6/1 kV) part?

Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.