Watertight Door (Deck)
A watertight door on a deck structure is built and tested to a defined head of water so it can stay closed against flooding on the deck it protects, unlike a weathertight door, which only needs to keep out rain and spray at sea.
What to check on a Watertight Door (Deck).
1 models from MacGregor in Watertight Door (Deck). Below: the full model list.
What distinguishes a watertight door from other deck openings
A watertight door is designed and tested to hold back a specified head of water without significant leakage, so that closing it actually contributes to the vessel's damage stability and subdivision. A weathertight door, by contrast, is only required to keep out rain, spray and green water in normal sea conditions - it is not rated to resist a static head and does not count toward the ship's subdivision calculations. The two are often confused because both use similar-looking dogs and gaskets, but a watertight door carries a rating and test certificate that a weathertight door does not need.
Legend
- COAMING / FRAME
- HINGES (left side)
- DOGS (clamping handles, typical)
- DOOR LEAF
- GASKET SEAL
- RAISED SILL (watertight)
Main components
Door leaf and frame
Steel plate leaf, typically stiffened, set into a welded steel frame built into the bulkhead or deckhouse structure, with the frame forming part of the watertight boundary itself.
Gasket and dogging arrangement
A continuous rubber gasket compressed by dogs, either individual hand-operated dogs or a single wheel-operated central mechanism, provides the seal around the full perimeter; hinge-side dogs are as important as the handle side, since an undogged hinge edge is a common leak path.
Read the full guide
Power operation, where fitted
On doors required to be remotely closable under SOLAS, typically below the freeboard deck on cargo ships and at subdivision boundaries on passenger ships, a hydraulic or electric actuator with local and bridge indication is fitted, along with an audible warning before remote closure.
Selection and sizing
The door is specified by its location in the subdivision arrangement, not chosen freely by the yard:
- Design head of water, set by the deck and compartment the door protects in the approved stability booklet
- Manual versus remotely-operated closing, determined by SOLAS requirements for the door's position relative to the freeboard deck
- Opening size and sill height, balancing crew access against the freeboard and stability assumptions the door was approved under
- Material and coating spec suited to the exposure - exterior doors see far more corrosion than internal watertight doors
Regulations and class
SOLAS Chapter II-1 governs watertight door requirements, including which doors must be capable of remote closing from the bridge, indication of door status on the bridge, and the requirement that doors below the margin line normally remain closed at sea. Class rules require periodic operational testing of remote closing and local dogging, with results logged, and surveyors check both the physical seal condition and the indication system during periodic surveys.
Typical faults
| Fault | Cause | Consequence |
|---|---|---|
| Gasket leakage | Perished or torn rubber gasket, or dogs left loose in daily use | Water ingress under head, false sense of watertight integrity |
| Hinge-side dogs left open | Crew habit of only dogging the handle side for quick access | Door not actually watertight despite appearing closed |
| Remote closing failure | Hydraulic or electrical actuator fault, corroded limit switches | Door cannot be closed from the bridge in an emergency |
| Indicator mismatch | Position switch out of adjustment | Bridge panel shows closed when the door is actually open, or vice versa |
What to look for in a supplier
- Type approval certificate matching the design head of water required for the door's actual location
- Spare gasket profile matched exactly to the frame, since generic gasket stock rarely seals correctly
- Support for the specific remote operation system already fitted, including hydraulic power pack type and control voltage
- Coating system suited to the deck location, given how much more exterior doors corrode than interior ones
A watertight door dogged only on the handle side will pass a casual glance but fail its purpose completely - check every dog, hinge side included, not just that the door looks shut.
Models in this type.
The best-documented model of each manufacturer first, then the next — 1 of 1 models in Watertight Door (Deck). Every row links to full specifications, documents and service notes.
Manufacturers.
All 18 manufacturers with models of Watertight Door (Deck). Names with a manufacturer page open it; the others open a search across the full library.
All manufacturers in the libraryAlso in Deck Fittings & Hardware.
The other equipment types in this category.
Inspection findings for this equipment
From public port state control and US Coast Guard records; OceanSphere assigns them to this equipment type from the descriptions.
Deficiency codes – USCG port state control – foreign-flag vessels
- 03107 · Doors – 158 findings
- 02101 · Closing devices/watertight doors – 120 findings
- 08110 · Closing water-tight doors alarm – 7 findings
USCG components
- Doors – 1,395 findings, 13 with detention
- Closing devices/watertight doors – 721 findings, 21 with detention
- Closing water-tight doors alarm – 56 findings, 1 with detention
- Door – 55 findings
Investigation reports
- 2008-11-03 · MAIB (UK) · Crush incident involving hydraulically operated watertight door on ro-ro passenger vessel Eurovoyager
- 2008-09-08 · MAIB (UK) · Crush incident involving power operated watertight door on ro-ro cargo vessel Ark Forwarder with loss of 1 life
- 2001-08-04 · MAIB (UK) · Crush incident involving power operated watertight door on passenger cruise ship Royal Princess with 1 person injured
- 1998-11-10 · MAIB (UK) · Crush incident with power operated watertight door on ro-ro passenger ferry P&OSL Kent with loss of 1 life
Write to us about your machine — the answer comes by e-mail.
Name the make and the model and what the job is: a spare, a service call, a second opinion on a data sheet. We answer by e-mail.
No details at hand? A photo of the rating plate or the part is enough — simply attach it to the request.
Questions that come up with this equipment.
Is Watertight Door (Deck) data free?
Yes. Every model page, every guide and every datasheet for this type is readable without an account. An account adds saved searches and requests, nothing is taken away.
My model is missing — what now?
Send us the nameplate. We identify it by hand, add it to the library, and if you need a part or a service, the request is already on our desk.
Can you source a Watertight Door (Deck) part?
Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.