Library› Engine Room› Heat Exchangers› Central Cooler (Plate Type)
Heat Exchangers

Central Cooler (Plate Type)

A plate-type central cooler is the single heat exchanger separating the aggressive raw seawater circuit from the closed fresh water system serving the main engine, gensets and auxiliaries, so its gaskets and plates are the one barrier standing between corrosive seawater and everything downstream.

900models
Alfa Laval
Knowledge

What to check on a Central Cooler (Plate Type).

900 models from Alfa Laval in Central Cooler (Plate Type). Below: the full model list.

What defines this type

A plate heat exchanger stacks pressed metal plates in a frame so that seawater and fresh water flow in alternating channels, in counter-flow, separated only by the plate and its gasket. Compared with a shell-and-tube design, the plate arrangement gives a much higher heat transfer coefficient per unit of footprint, which is why it is the common choice for a central cooler. The central cooler concept means one unit does the work: raw seawater cools a closed fresh water circuit once, and that fresh water then goes on to cool the main engine jacket, generator engines, air coolers and lube oil coolers in series or parallel, instead of each of those systems having its own dedicated seawater-cooled exchanger.

Plate-type central cooler flow arrangement
Counterflow schematic of a plate heat exchanger showing seawater and fresh water entering at opposite ends of the plate pack, held between a fixed and a moving frame plate on tie bolts.

Legend

  1. Tie bolt
  2. Seawater outlet
  3. Fresh water inlet
  4. Seawater inlet
  5. Fresh water outlet
  6. Fixed frame plate
  7. Plate pack
  8. Moving frame plate

Main components

  • Plate pack — pressed titanium or stainless steel plates, the corrugation pattern setting the turbulence and heat transfer performance.
  • Frame plate and moving pressure plate — fixed and movable end plates that clamp the pack together.
  • Gaskets — NBR or EPDM seals between plates, the component most exposed to chemical and thermal ageing.
  • Tie bolts — compress the plate pack to the tension the manufacturer specifies for the gaskets to seal.
  • Connections and support frame — seawater and fresh water inlet/outlet, and the carrying bars the pack slides on for opening.

Selection / sizing

The starting figure is total heat load to be rejected across all systems the central fresh water circuit serves, sized against a design seawater temperature that reflects the worst realistic case for the trading area, often around 32°C for tropical service. Plate material is normally titanium for seawater resistance; the number of plates and the gasket type are set by the required approach temperature and the pressure drop the pumps can supply on both sides. Vessels that cannot tolerate losing cooling fit two coolers in a duty/standby or split-load arrangement rather than relying on a single unit.

Regulations / Class

Class rules require reliable cooling capacity for essential machinery and periodic pressure testing of the cooler after it has been opened for cleaning or gasket replacement, following the survey requirements applicable to the vessel's class notation. Gasket material near machinery space boundaries is expected to meet the fire safety standard applicable to that location under the vessel's class and flag requirements.

Read the full guide

Typical faults

  • Marine growth or scaling on the seawater side — reduces heat transfer, shows up as a slowly rising fresh water temperature that a routine inspection can miss until it affects engine performance.
  • Gasket degradation — allows internal leakage, letting seawater track into the fresh water circuit and introduce salt into the engine jacket water.
  • Plate erosion or pitting — eventually perforates, letting seawater leak directly into the fresh water side.
  • Incorrect tie bolt torque after reassembly — causes an external leak or uneven plate compression that shortens gasket life.

What to look for in a supplier

  • Plate material recommendation matched to the actual seawater quality and design temperature, not a generic default.
  • Gasket material compatible with the fresh water circuit's corrosion inhibitor chemistry.
  • A stated heat transfer guarantee that includes a realistic fouling factor, not a clean-plate figure.
  • Spare plates and gaskets available without a long lead time, and a pack that opens for cleaning without special tools.

A rising fresh water outlet temperature at unchanged seawater conditions is usually the first sign of fouling — check it before assuming the engine itself is the problem.

Models

Models in this type.

The best-documented model of each manufacturer first, then the next — 100 of 900 models in Central Cooler (Plate Type). Every row links to full specifications, documents and service notes.

Showing only Alfa Laval. Show all manufacturers
Alfa LavalM10-BFG 2000 kW Alfa LavalAC10 Alfa LavalAC10-120P Alfa LavalAC10-150P Alfa LavalAC10-180P Alfa LavalAC10-30P Alfa LavalAC10-60P Alfa LavalAC10-90P Alfa LavalAC10-MAX Alfa LavalAC1000 Alfa LavalAC1000-120P Alfa LavalAC1000-150P Alfa LavalAC1000-180P Alfa LavalAC1000-30P Alfa LavalAC1000-60P Alfa LavalAC1000-90P Alfa LavalAC1000-MAX Alfa LavalAC112 Alfa LavalAC112-120P Alfa LavalAC112-150P Alfa LavalAC112-180P Alfa LavalAC112-30P Alfa LavalAC112-60P Alfa LavalAC112-90P Alfa LavalAC112-MAX Alfa LavalAC120 Alfa LavalAC120-120P Alfa LavalAC120-150P Alfa LavalAC120-180P Alfa LavalAC120-30P Alfa LavalAC120-60P Alfa LavalAC120-90P Alfa LavalAC120-MAX Alfa LavalAC16 Alfa LavalAC16-120P Alfa LavalAC16-150P Alfa LavalAC16-180P Alfa LavalAC16-30P Alfa LavalAC16-60P Alfa LavalAC16-90P Alfa LavalAC16-MAX Alfa LavalAC18 Alfa LavalAC18-120P Alfa LavalAC18-150P Alfa LavalAC18-180P Alfa LavalAC18-30P Alfa LavalAC18-60P Alfa LavalAC18-90P Alfa LavalAC18-MAX Alfa LavalAC220 Alfa LavalAC220-120P Alfa LavalAC220-150P Alfa LavalAC220-180P Alfa LavalAC220-30P Alfa LavalAC220-60P Alfa LavalAC220-90P Alfa LavalAC220-MAX Alfa LavalAC230 Alfa LavalAC230-120P Alfa LavalAC230-150P Alfa LavalAC230-180P Alfa LavalAC230-30P Alfa LavalAC230-60P Alfa LavalAC230-90P Alfa LavalAC230-MAX Alfa LavalAC232 Alfa LavalAC232-120P Alfa LavalAC232-150P Alfa LavalAC232-180P Alfa LavalAC232-30P Alfa LavalAC232-60P Alfa LavalAC232-90P Alfa LavalAC232-MAX Alfa LavalAC30 Alfa LavalAC30-120P Alfa LavalAC30-150P Alfa LavalAC30-180P Alfa LavalAC30-30P Alfa LavalAC30-60P Alfa LavalAC30-90P Alfa LavalAC30-MAX Alfa LavalAC300 Alfa LavalAC300-120P Alfa LavalAC300-150P Alfa LavalAC300-180P Alfa LavalAC300-30P Alfa LavalAC300-60P Alfa LavalAC300-90P Alfa LavalAC300-MAX Alfa LavalAC32 Alfa LavalAC32-120P Alfa LavalAC32-150P Alfa LavalAC32-180P Alfa LavalAC32-30P Alfa LavalAC32-60P Alfa LavalAC32-90P Alfa LavalAC32-MAX Alfa LavalAC400 Alfa LavalAC400-120P Alfa LavalAC400-150P
By manufacturer

Manufacturers.

All 5 manufacturers with models of Central Cooler (Plate Type). Names with a manufacturer page open it; the others open a search across the full library.

All manufacturers
Would you like to know more?

One request. A person reads it and replies by e-mail.

Tell us the manufacturer, the model and what you need — a part, a service call, a second opinion. A person reads every request and replies by e-mail.

No details at hand? A photo of the rating plate or the part is enough — simply attach it to the request.

Frequently asked

Three things people ask first.

Is Central Cooler (Plate Type) data free?

Yes. Every model page, every guide and every datasheet for this type is readable without an account. An account adds saved searches and requests, nothing is taken away.

My model is missing — what now?

Send us the nameplate. We identify it by hand, add it to the library, and if you need a part or a service, the request is already on our desk.

Can you source a Central Cooler (Plate Type) part?

Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.