Skip to content
OceanSphereDEENPL
OceanSphereENGINES
Library› HVAC› Ventilation› Exhaust Fan
Ventilation

Exhaust Fan

An exhaust fan pulls air out of a space to create negative pressure relative to its surroundings, which is why paint lockers, galleys and battery rooms depend on extraction rather than supply to keep fumes, heat or hydrogen from spreading beyond the compartment they start in.

66models
Howden Marine
Knowledge

What to check on an Exhaust Fan.

66 models from Howden Marine in Exhaust Fan. Below: the full model list.

The Job an Exhaust Fan Does

An exhaust fan removes air from a compartment and discharges it to open deck, pulling the space slightly negative relative to the spaces around it. That negative pressure is deliberate: a galley extract keeps cooking fumes and grease-laden air from drifting into the accommodation, a paint locker extract keeps solvent vapour from building up, and a battery room extract removes hydrogen given off during charging before it reaches an ignition source. Engine room extraction works differently, removing heat and combustion by-products roughly in balance with the supply fans rather than running deliberately negative. The direction of airflow, not the fan itself, is what separates this equipment from a supply fan doing the opposite job in the same ventilation system.

Exhaust fan ventilation arrangement
Arrangement diagram of an exhaust fan extracting air from an enclosed space such as a paint locker through a duct and discharging it to atmosphere above deck, with make-up air entering through the door gap and the space held at negative pressure.

Legend

  1. discharge to atmosphere, above deck
  2. extraction duct
  3. space, e.g. paint locker
  4. held at negative pressure
  5. make-up air, door gap

Main Components

  • Impeller – axial for high-volume, low-resistance duties like engine room extraction, centrifugal where duct runs and resistance are higher.
  • Motor – standard enclosure for general spaces, explosion-protected (Ex d or Ex e) where the fan serves a hazardous area such as a battery room or a gas-dangerous space.
  • Flexible duct connection – isolates fan vibration from the ductwork and structure.
  • Fire damper – fitted where the duct passes a fire boundary, normally open and closed remotely or by fusible link.
  • Spark-proof grille or non-ferrous impeller – required where the fan handles air that could contain flammable vapour.
  • Weather terminal – goose-neck or cowl on open deck with a non-return flap to stop green water or backflow entering the duct.

Selection and Sizing

Air change targets vary sharply by space: a paint locker typically needs mechanical extraction sized for a set minimum number of air changes per hour under class rules, a galley needs enough capacity to clear heat and grease-laden air at the cooking line, and an engine room extract is sized to match its supply fans rather than to a fixed ACH figure. Static pressure has to cover duct losses, grille resistance and any silencer, and hazardous-area duties fix the motor's explosion-protection class before capacity is even considered.

Regulations and Class

SOLAS Chapter II-2 requires fire dampers at fire boundaries and remote stopping of ventilation fans serving machinery spaces and galleys from outside the space, coordinated with the release of any fixed fire-extinguishing system so the fire is starved of ventilation rather than fed by it. Paint locker mechanical extraction is a SOLAS requirement in its own right. Hazardous-area fans, such as those serving battery rooms or gas-dangerous spaces, must meet the applicable IACS unified requirements for spark-proof or explosion-protected construction.

Read the full guide

Typical Faults

FaultConsequence
Bearing wear from continuous dutyVibration, eventual seizure and loss of extraction to the space it serves
Grease-clogged galley duct or filterReduced extraction and a real fire load building up inside the ductwork
Fire damper seized by paint or corrosionDamper fails the fire test open or blocks normal ventilation shut
Weather terminal non-return flap seizedWater ingress in heavy weather, or duct backflow when the fan stops
Ex-rated motor replaced with a standard unitExplosion protection is lost without any visible change to the installation

What to Look for in a Supplier

  • Ex motor certificates matched to the specific zone classification of the space, not a generic explosion-proof label.
  • Damper actuators compatible with the ship's existing fire detection and release panel.
  • Spare impellers and bearings held for the exact model fitted.
  • Noise and vibration figures where the fan sits near accommodation.

Test the fire damper and emergency stop for every extract fan at each fire drill, not just the ones an inspector is likely to check; a damper that has silently seized shut is invisible until the fan can no longer clear the space.

Models

Models in this type.

The best-documented model of each manufacturer first, then the next — 66 of 66 models in Exhaust Fan. Every row links to full specifications, documents and service notes.

Showing only Howden Marine. Show all manufacturers
Howden MarineHAF Exhaust 10000m3h accommodation 3 kW Howden MarineHAF Exhaust 10000m3h cargo hold 3 kW Howden MarineHAF Exhaust 10000m3h engine room 3 kW Howden MarineHAF Exhaust 1000m3h accommodation 0.5 kW Howden MarineHAF Exhaust 1000m3h cargo hold 0.5 kW Howden MarineHAF Exhaust 1000m3h engine room 0.5 kW Howden MarineHAF Exhaust 15000m3h accommodation 4.5 kW Howden MarineHAF Exhaust 15000m3h cargo hold 4.5 kW Howden MarineHAF Exhaust 15000m3h engine room 4.5 kW Howden MarineHAF Exhaust 20000m3h accommodation 6 kW Howden MarineHAF Exhaust 20000m3h cargo hold 6 kW Howden MarineHAF Exhaust 20000m3h engine room 6 kW Howden MarineHAF Exhaust 2000m3h accommodation 1 kW Howden MarineHAF Exhaust 2000m3h cargo hold 1 kW Howden MarineHAF Exhaust 2000m3h engine room 1 kW Howden MarineHAF Exhaust 30000m3h accommodation 9 kW Howden MarineHAF Exhaust 30000m3h cargo hold 9 kW Howden MarineHAF Exhaust 30000m3h engine room 9 kW Howden MarineHAF Exhaust 3000m3h accommodation 1.5 kW Howden MarineHAF Exhaust 3000m3h cargo hold 1.5 kW Howden MarineHAF Exhaust 3000m3h engine room 1.5 kW Howden MarineHAF Exhaust 50000m3h accommodation 15 kW Howden MarineHAF Exhaust 50000m3h cargo hold 15 kW Howden MarineHAF Exhaust 50000m3h engine room 15 kW Howden MarineHAF Exhaust 5000m3h accommodation 2.5 kW Howden MarineHAF Exhaust 5000m3h cargo hold 2.5 kW Howden MarineHAF Exhaust 5000m3h engine room 2.5 kW Howden MarineHAF Exhaust 500m3h accommodation 0.2 kW Howden MarineHAF Exhaust 500m3h cargo hold 0.2 kW Howden MarineHAF Exhaust 500m3h engine room 0.2 kW Howden MarineHAF Exhaust 8000m3h accommodation 4 kW Howden MarineHAF Exhaust 8000m3h cargo hold 4 kW Howden MarineHAF Exhaust 8000m3h engine room 4 kW Howden MarineHMF Exhaust 10000m3h accommodation 3 kW Howden MarineHMF Exhaust 10000m3h cargo hold 3 kW Howden MarineHMF Exhaust 10000m3h engine room 3 kW Howden MarineHMF Exhaust 1000m3h accommodation 0.5 kW Howden MarineHMF Exhaust 1000m3h cargo hold 0.5 kW Howden MarineHMF Exhaust 1000m3h engine room 0.5 kW Howden MarineHMF Exhaust 15000m3h accommodation 4.5 kW Howden MarineHMF Exhaust 15000m3h cargo hold 4.5 kW Howden MarineHMF Exhaust 15000m3h engine room 4.5 kW Howden MarineHMF Exhaust 20000m3h accommodation 6 kW Howden MarineHMF Exhaust 20000m3h cargo hold 6 kW Howden MarineHMF Exhaust 20000m3h engine room 6 kW Howden MarineHMF Exhaust 2000m3h accommodation 1 kW Howden MarineHMF Exhaust 2000m3h cargo hold 1 kW Howden MarineHMF Exhaust 2000m3h engine room 1 kW Howden MarineHMF Exhaust 30000m3h accommodation 9 kW Howden MarineHMF Exhaust 30000m3h cargo hold 9 kW Howden MarineHMF Exhaust 30000m3h engine room 9 kW Howden MarineHMF Exhaust 3000m3h accommodation 1.5 kW Howden MarineHMF Exhaust 3000m3h cargo hold 1.5 kW Howden MarineHMF Exhaust 3000m3h engine room 1.5 kW Howden MarineHMF Exhaust 50000m3h accommodation 15 kW Howden MarineHMF Exhaust 50000m3h cargo hold 15 kW Howden MarineHMF Exhaust 50000m3h engine room 15 kW Howden MarineHMF Exhaust 5000m3h accommodation 2.5 kW Howden MarineHMF Exhaust 5000m3h cargo hold 2.5 kW Howden MarineHMF Exhaust 5000m3h engine room 2.5 kW Howden MarineHMF Exhaust 500m3h accommodation 0.2 kW Howden MarineHMF Exhaust 500m3h cargo hold 0.2 kW Howden MarineHMF Exhaust 500m3h engine room 0.2 kW Howden MarineHMF Exhaust 8000m3h accommodation 4 kW Howden MarineHMF Exhaust 8000m3h cargo hold 4 kW Howden MarineHMF Exhaust 8000m3h engine room 4 kW
By manufacturer

Manufacturers.

All 8 manufacturers with models of Exhaust Fan. Names with a manufacturer page open it; the others open a search across the full library.

All manufacturers
Related types

Also in Ventilation.

The other equipment types in this category.

Axial FanCentrifugal FanEmergency Fire FanEngine Room Supply FanFire/Smoke DamperSupply Fan
Would you like to know more?

One request. A person reads it and replies by e-mail.

Tell us the manufacturer, the model and what you need — a part, a service call, a second opinion. A person reads every request and replies by e-mail.

No details at hand? A photo of the rating plate or the part is enough — simply attach it to the request.

Frequently asked

Three things people ask first.

Is Exhaust Fan data free?

Yes. Every model page, every guide and every datasheet for this type is readable without an account. An account adds saved searches and requests, nothing is taken away.

My model is missing — what now?

Send us the nameplate. We identify it by hand, add it to the library, and if you need a part or a service, the request is already on our desk.

Can you source a Exhaust Fan part?

Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.