OceanSphereEnginesPartsWorkServiceNetworkAdditiveFree accountLog inDEENPL
OceanSphereENGINES
Library Safety & LSA Fixed Fire Suppression Dry Chemical System
Fixed Fire Suppression

Dry Chemical System

A fixed dry chemical system floods a protected space with powder from a bank of pressurised cylinders through fixed piping and nozzles, giving the same chemical chain-breaking action as a portable extinguisher but sized to knock down a fire across a galley range, paint locker or helideck refuelling point in one release.

11models 5manufacturers
Models

Models in this type.

The 11 models with the most complete data of 11 in Dry Chemical System. Every row links to full specifications, documents and service notes.

By manufacturer

Manufacturers.

All 5 manufacturers with models of Dry Chemical System. Every name opens a search across the full library.

Related types

Also in Fixed Fire Suppression.

The other equipment types in this category.

CO2 Fire SuppressionCO2 Fixed Fire SystemClean Agent SystemDeluge/Sprinkler SystemFM-200/Novec SystemFixed Gas Extinguishing SystemFoam Fire SuppressionFoam Fire SystemWater Mist SystemWater Mist System (Hi-Fog)
Knowledge

What to check on a Dry Chemical System.

Portable extinguishers cover a fire a crew member can reach and fight directly; a fixed dry chemical system is built for spaces where a fire can spread faster than a hand extinguisher can control it, or where crew access is limited during a fire, such as a galley deep-fat range hood and duct, a paint locker, or a helicopter deck fuelling point. Rather than relying on someone carrying an extinguisher to the seat of the fire, the system discharges powder automatically or by remote pull station through fixed piping and…

What a fixed dry chemical system is for

Portable extinguishers cover a fire a crew member can reach and fight directly; a fixed dry chemical system is built for spaces where a fire can spread faster than a hand extinguisher can control it, or where crew access is limited during a fire, such as a galley deep-fat range hood and duct, a paint locker, or a helicopter deck fuelling point. Rather than relying on someone carrying an extinguisher to the seat of the fire, the system discharges powder automatically or by remote pull station through fixed piping and nozzles aimed directly at the hazard.

Fixed dry chemical powder system
Flow diagram showing dry chemical cylinders pressurised with propellant gas, discharging through a manifold and fixed piping to nozzles in the protected space, triggered from a manual pull station.

Main components

Powder storage cylinders

One or more pressure vessels hold the dry chemical charge, usually a sodium or potassium bicarbonate based powder chosen for the fire class expected in that space, kept dry and free-flowing by a moisture-tight fill and periodic condition checks.

Expellant gas cylinder

A separate cylinder of nitrogen or CO2 provides the propelling gas, either stored ready-connected or released by a pilot cylinder that then pressurises the main powder cylinders, depending on system design.

Fixed piping and discharge nozzles

Sized and positioned during design to deliver a calculated powder density across the protected area or directly onto specific equipment, such as a fryer or duct opening, within seconds of activation.

Detection and release station

Heat or flame detectors trigger automatic release in unmanned or high-risk spaces; a manual pull station, always provided as a backup, lets crew release the system from outside the protected space.

Selection and sizing

The system is engineered to the specific hazard, not sold as a fixed capacity unit:

  • Protected area or volume, and whether the hazard is a local point source such as a fryer versus a whole enclosure such as a paint locker.
  • Powder type matched to the expected fire class, since bicarbonate powders suited to class B fires differ from the ammonium phosphate powders used for combined class A/B/C risk.
  • Discharge time and powder quantity calculated to achieve extinguishing concentration before the fire can regrow, typically within ten to thirty seconds.
  • Detection method appropriate to the space, balancing fast response against false discharge risk from normal galley heat.

Regulations and class

SOLAS Chapter II-2 requires fixed fire-extinguishing arrangements for galley ranges with deep-fat cooking equipment and for certain other specific hazards, and sets performance criteria the system's design must meet rather than mandating one brand or layout. Class societies require the system design to be approved against a recognised standard before installation, and periodic servicing, weighing of powder cylinders, and pressure testing of expellant gas cylinders at intervals set by the equipment standard, commonly aligned with the vessel's fire equipment survey cycle.

Typical faults

FaultConsequence
Caked or moisture-contaminated powderReduced or blocked discharge through the nozzles when the system is activated
Expellant cylinder pressure below charge weightPowder is not propelled through the piping with enough force to reach the nozzles
Corroded or misaligned discharge nozzlesPowder pattern misses the actual hazard, such as the fryer surface or duct opening
Detector fouled by cooking greaseAutomatic release fails to trigger, or triggers falsely from normal heat, eroding crew trust in the system
Manual pull station cable seized or disconnectedBackup release does not work when crew activate it during an actual fire

What to look for in a supplier

  • Approval to service the specific system brand and design, since powder chemistry and cylinder hardware are not interchangeable between manufacturers.
  • Documented weighing and condition checks of powder cylinders at every service, not just a visual inspection.
  • Ability to pressure test and, where due, hydrostatically retest the expellant gas cylinders on the same visit.
  • Familiarity with galley hood and duct nozzle layouts specifically, since misaimed nozzles are a common installation-era defect that only shows up at commissioning test.

Ask for the actual discharge test result, not just a service sticker, whenever the system is due; a system that passes a static weight and pressure check can still fail to reach the fryer surface if a nozzle was reaimed or blocked during galley cleaning.

Search by manufacturer AFRISOWISKASwagelokAlfa Laval S.p.A.MAN Energy SolutionsSEIMIWärtsiläEndress+HauserABB MarineAlfa LavalMacGregorNovenco MarineCarrier MarineSiemens MarineHeinen & Hopman
Would you like to know more?

One request. A person answers within 24 hours on working days.

Tell us the manufacturer, the model and what you need — a part, a service call, a second opinion. Our desk asks the right suppliers from a network of over 114,000 companies and comes back with a quote or a sourcing plan, not a search page.

Frequently asked

Three things people ask first.

Is Dry Chemical System data free?

Yes. Every model page, every guide and every datasheet for this type is readable without an account. An account adds saved searches and requests, nothing is taken away.

My model is missing — what now?

Send us the nameplate. We identify it by hand, add it to the library, and if you need a part or a service, the request is already on our desk.

Can you source a Dry Chemical System part?

Yes. Tell us the manufacturer, the model and what you need — our desk asks the right suppliers from a network of over 114,000 companies and comes back with a quote or a sourcing plan.