Heat Exchangers

Shell-and-Tube Cooler

A shell-and-tube cooler passes cooling water through a tube bundle inside a shell while oil or jacket water flows around it, trading the compactness of a plate cooler for tubes that can be mechanically cleaned and individually plugged without stopping the plant.

Kelvion
Knowledge

What to check on a Shell-and-Tube Cooler.

3 models from Kelvion in Shell-and-Tube Cooler. Below: the full model list.

What sets a shell-and-tube cooler apart

Inside the shell, a bundle of straight or U-tubes carries one fluid, usually sea water or low-temperature fresh water, while the second fluid, jacket water, lubricating oil or charge air, flows through the shell around the outside of the tubes, redirected back and forth by baffles to improve contact time. Compared with a plate heat exchanger, a shell-and-tube design gives up compactness and thermal efficiency per square metre, but it tolerates dirtier, more corrosive water, handles higher pressure differentials without gasket concerns, and lets a single leaking tube be plugged and left out of service rather than forcing a full plate-pack strip-down.

Shell-and-tube cooler cross-section
Cross-section of a shell and tube cooler: seawater runs straight through a tube bundle held by two tube sheets, while hot oil enters the shell side, is guided around baffle plates, and leaves cooled.

Legend

  1. oil in (hot, shell side)
  2. shell (steel body)
  3. seawater in
  4. tube sheet
  5. baffle plates (shell side)
  6. tube bundle (seawater side)
  7. seawater out
  8. oil out (cooled)

Main components

Shell

The outer pressure-containing cylinder, usually carbon steel with a corrosion allowance or a cladding on the water side.

Tube bundle

Copper-nickel tubes, 90/10 or 70/30 CuNi, are standard where raw sea water is the coolant, chosen for resistance to biofouling and erosion-corrosion; titanium tubes appear on high-duty or aggressive-water applications. Tube walls run roughly 0.7-1.2 mm.

Read the full guide

Tube sheets

Thick plates at each end that the tubes are expanded or welded into, separating the shell side from the water boxes.

Baffles

Segmental plates spaced along the bundle that force the shell-side fluid into a zig-zag path, raising turbulence and heat transfer at the cost of pressure drop.

Water boxes and end covers

Removable covers at each end that let the tube bundle be pulled for cleaning or replacement without disturbing the shell-side piping.

Selection and sizing

Sizing runs on heat duty in kW, the temperature approach between the two fluids, allowable pressure drop on each side, and a fouling factor assumed for the water quality expected in service. Sea water coolers are usually oversized against a clean-tube calculation specifically to absorb the fouling that will accumulate between cleanings. Tube material, number of passes and bundle length are the practical trade-offs weighed against available engine room space and the vessel's typical trading water quality.

Regulations and class

Shell-and-tube coolers in essential cooling services fall under class society rules for machinery piping systems, which set minimum design pressure, material approval and testing requirements, typically a hydrostatic test at 1.5 times design pressure. Where the cooler sits in a fuel oil or lubricating oil circuit near hot surfaces, SOLAS II-2 insulation and leakage-containment requirements apply to the surrounding installation rather than to the cooler itself. There is no fixed statutory survey interval specific to the cooler; it is covered under the periodic survey of the cooling water and lubricating oil systems in the vessel's class survey scheme.

Typical faults

FaultCauseConsequence
Tube foulingMarine growth, silt or scale on the water sideFalling heat transfer, rising jacket water or LO temperature over weeks
Tube erosionSea water velocity too high, or sand and grit ingestionWall thinning, eventual pinhole leak and cross-contamination
Galvanic corrosionMismatched tube and tube sheet materials, or exhausted sacrificial anodesLocalised pitting, tube failure well before nominal service life
Tube-to-tube-sheet leakExpansion fatigue or poor original rollingSea water into the oil or fresh water side, contaminating the lubricant
Water box gasket failureAge and thermal cyclingExternal leak, loss of cooling water inventory

What to look for in a supplier

  • Class-approved design with certified hydrostatic test records for both shell and tube sides.
  • Tube material recommendation matched to the vessel's actual trading area water quality, not a generic default.
  • Availability of replacement tube bundles or individual tubes sized to the existing tube sheet pattern, so a repair does not require a whole new cooler.
  • Anode fitment and access for renewal without pulling the full bundle.

Pull and inspect the tube bundle at the interval the water quality earns, not the interval on the maintenance sheet - a cooler running clean, filtered fresh water fouls far slower than one on raw estuary sea water.

Models

Models in this type.

The best-documented model of each manufacturer first, then the next — 3 of 3 models in Shell-and-Tube Cooler. Every row links to full specifications, documents and service notes.

Showing only Kelvion. Show all manufacturers
By manufacturer

Manufacturers.

All 7 manufacturers with models of Shell-and-Tube Cooler. Names with a manufacturer page open it; the others open a search across the full library.

All manufacturers in the library
More than the data sheet shows

Write to us about this model — the answer comes by e-mail.

Name the make and the model and what the job is: a spare, a service call, a second opinion on a data sheet. We answer by e-mail.

No details at hand? A photo of the rating plate or the part is enough — simply attach it to the request.

Frequently asked

Questions that come up with this equipment.

Is Shell-and-Tube Cooler data free?

Yes. Every model page, every guide and every datasheet for this type is readable without an account. An account adds saved searches and requests, nothing is taken away.

My model is missing — what now?

Send us the nameplate. We identify it by hand, add it to the library, and if you need a part or a service, the request is already on our desk.

Can you source a Shell-and-Tube Cooler part?

Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.