Skip to content
OceanSphereENGINES
Library› Engine Room› Auxiliary Engines› Auxiliary Engine (Generator Set)
Auxiliary Engines

Auxiliary Engine (Generator Set)

An auxiliary engine is a diesel genset built to run at constant speed for frequency-stable electrical output, not to drive a propeller — a distinction that shapes its governor, cooling, and load-acceptance design from the ground up.

MAN Energy Solutions
Knowledge

What to check on an Auxiliary Engine (Generator Set).

205 models from MAN Energy Solutions in Auxiliary Engine (Generator Set). Below: the full model list.

What makes this type

An auxiliary engine (generator diesel engine, or "aux") is coupled directly to an alternator and runs at a fixed synchronous speed — typically 1200, 1500, or 1800 rpm depending on frequency (50 or 60 Hz) and pole count — because the alternator's output frequency is locked to shaft speed. This is the core difference from a main propulsion engine, which is allowed to vary speed continuously with load. An aux engine's governor is tuned for tight speed regulation under sudden load steps, since connecting or dropping a large consumer (a cargo pump starting, a bow thruster engaging) has to be absorbed within a few percent of frequency deviation without tripping protective relays or blacking out the switchboard. Auxiliary engines usually run in multiples — two to four sets per ship — specifically so load can be shared and units can be swapped out for maintenance without losing power generation capability.

Marine auxiliary generator set
Marine auxiliary generator set on a common bedplate: the diesel engine drives the alternator through a flexible coupling, with the engine cooler above the engine, the exhaust outlet from the cylinder head, the control and terminal box on the alternator and resilient mounts under the bedplate.

Legend

  1. Engine cooler
  2. Exhaust outlet
  3. Cooling water to and from the engine
  4. Control and terminal box
  5. Diesel engine
  6. Alternator
  7. Flexible coupling
  8. Common bedplate
  9. Resilient mounts

Main components

Engine block and fuel injection

Most modern aux engines are medium- or high-speed four-stroke trunk-piston diesels, mechanically or electronically fuel injected; electronic (common-rail or unit-injector) control has become common because it improves transient load response, which matters more for a genset than a main engine.

Governor and AVR

The governor holds engine speed (hence frequency) constant; the alternator's automatic voltage regulator holds terminal voltage constant. Both must respond fast enough that a step load change does not push frequency or voltage outside the narrow band the switchboard protection allows.

Read the full guide

Alternator

Directly coupled, sized in kVA with a power factor rating (commonly 0.8) that determines real kW output versus apparent power capacity.

Cooling and lube oil systems

Sized for continuous duty at rated load, since unlike a main engine that may run at reduced load for long passages, gensets are commonly loaded close to their rating whenever running to keep specific fuel consumption reasonable.

Selection / Sizing

Sizing starts from the ship's electrical load list at different operating conditions (at sea, in port, cargo operations, manoeuvring) and picks a genset combination that covers peak load with one unit out of service (N+1 redundancy is standard practice, and mandatory in some class notations). Running gensets well below rated load for long periods causes its own problems — incomplete combustion, cylinder glazing, exhaust valve fouling — so the number and size of units is chosen to keep each running set reasonably loaded across the ship's typical load profile, rather than fitting one oversized set that is always lightly loaded.

Regulations / Class

Class rules require a minimum number of generating sets such that with the largest set out of service, the remainder can supply all services needed for propulsion, steering, and safety. MARPOL Annex VI NOx Tier limits apply based on engine build date and size, same as main engines, and an Engine International Air Pollution Prevention (EIAPP) certificate is required per engine. SOLAS requires an emergency source of power separate from the main gensets, which is a different piece of equipment entirely (see Emergency Generator Sets).

Typical faults

  • Cylinder liner glazing from prolonged light-load running — poor ring seating leads to rising lube oil consumption and blow-by.
  • Governor hunting — speed oscillation under load, often from worn linkage or actuator issues, that causes frequency instability across the switchboard.
  • Turbocharger fouling — reduced air supply under load, showing up as high exhaust temperature and falling power output at rated load.
  • Injector wear affecting load sharing — uneven fuel delivery between cylinders shows up as vibration and uneven exhaust temperatures across units.
  • AVR drift — slow voltage regulation that causes reactive load-sharing problems when running gensets in parallel.

What to look for in a supplier

  • NOx certification (EIAPP) matched to the intended trading area and build date, since retrofitting Tier III compliance later is costly.
  • Genset packages tested together (engine, alternator, governor, AVR) rather than components sourced separately and matched on paper.
  • Parts and service network reach in the ship's actual trading pattern, not just the flag state.
  • Documented load-acceptance figures (percentage step load the set can absorb without exceeding frequency/voltage transient limits) for the specific application.

A genset that never gets loaded above 40% for weeks at a time is quietly glazing its liners — rotate load between units and run one hard periodically rather than always splitting load evenly and lightly.

Models

Models in this type.

The best-documented model of each manufacturer first, then the next — 100 of 205 models in Auxiliary Engine (Generator Set). Every row links to full specifications, documents and service notes.

Page 1 of 3 · Next →
Showing only MAN Energy Solutions. Show all manufacturers
MAN Energy Solutions10L21/31-GS-50Hz 2,000 kW MAN Energy Solutions10L21/31-GS-60Hz 2,000 kW MAN Energy Solutions10L21/31DF-GS-50Hz 1,850 kW MAN Energy Solutions10L21/31DF-GS-60Hz 1,850 kW MAN Energy Solutions10L32/44CR-GS-50Hz 4,800 kW MAN Energy Solutions10L32/44CR-GS-60Hz 4,800 kW MAN Energy Solutions10L35/44DF-GS-50Hz 5,400 kW MAN Energy Solutions10L35/44DF-GS-60Hz 5,400 kW MAN Energy Solutions12V21/31-GS-50Hz 2,400 kW MAN Energy Solutions12V21/31-GS-60Hz 2,400 kW MAN Energy Solutions12V21/31DF-GS-50Hz 2,220 kW MAN Energy Solutions12V21/31DF-GS-60Hz 2,220 kW MAN Energy Solutions12V23/30H-GS-50Hz 2,220 kW MAN Energy Solutions12V23/30H-GS-60Hz 2,220 kW MAN Energy Solutions12V27/38-GS-50Hz 4,080 kW MAN Energy Solutions12V27/38-GS-60Hz 4,080 kW MAN Energy Solutions12V28/33D-GS-50Hz 3,840 kW MAN Energy Solutions12V28/33D-GS-60Hz 3,840 kW MAN Energy Solutions12V32/40-GS-50Hz 5,400 kW MAN Energy Solutions12V32/40-GS-60Hz 5,400 kW MAN Energy Solutions12V32/44CR-GS-50Hz 5,760 kW MAN Energy Solutions12V32/44CR-GS-60Hz 5,760 kW MAN Energy Solutions12V35/44DF-GS-50Hz 6,480 kW MAN Energy Solutions12V35/44DF-GS-60Hz 6,480 kW MAN Energy Solutions12V51/60DF-GS-50Hz 13,800 kW MAN Energy Solutions12V51/60DF-GS-60Hz 13,800 kW MAN Energy Solutions14V21/31-GS-50Hz 2,800 kW MAN Energy Solutions14V21/31-GS-60Hz 2,800 kW MAN Energy Solutions14V21/31DF-GS-50Hz 2,590 kW MAN Energy Solutions14V21/31DF-GS-60Hz 2,590 kW MAN Energy Solutions14V23/30H-GS-50Hz 2,590 kW MAN Energy Solutions14V23/30H-GS-60Hz 2,590 kW MAN Energy Solutions14V27/38-GS-50Hz 4,760 kW MAN Energy Solutions14V27/38-GS-60Hz 4,760 kW MAN Energy Solutions14V28/33D-GS-50Hz 4,480 kW MAN Energy Solutions14V28/33D-GS-60Hz 4,480 kW MAN Energy Solutions14V32/40-GS-50Hz 6,300 kW MAN Energy Solutions14V32/40-GS-60Hz 6,300 kW MAN Energy Solutions14V32/44CR-GS-50Hz 6,720 kW MAN Energy Solutions14V32/44CR-GS-60Hz 6,720 kW MAN Energy Solutions14V35/44DF-GS-50Hz 7,560 kW MAN Energy Solutions14V35/44DF-GS-60Hz 7,560 kW MAN Energy Solutions14V51/60DF-GS-50Hz 16,100 kW MAN Energy Solutions14V51/60DF-GS-60Hz 16,100 kW MAN Energy Solutions16V23/30H-GS-50Hz 2,960 kW MAN Energy Solutions16V23/30H-GS-60Hz 2,960 kW MAN Energy Solutions16V27/38-GS-50Hz 5,440 kW MAN Energy Solutions16V27/38-GS-60Hz 5,440 kW MAN Energy Solutions16V32/40-GS-50Hz 7,200 kW MAN Energy Solutions16V32/40-GS-60Hz 7,200 kW MAN Energy Solutions16V32/44CR-GS-50Hz 7,680 kW MAN Energy Solutions16V32/44CR-GS-60Hz 7,680 kW MAN Energy Solutions16V35/44DF-GS-50Hz 8,640 kW MAN Energy Solutions16V35/44DF-GS-60Hz 8,640 kW MAN Energy Solutions16V51/60DF-GS-50Hz 18,400 kW MAN Energy Solutions16V51/60DF-GS-60Hz 18,400 kW MAN Energy Solutions18V27/38-GS-50Hz 6,120 kW MAN Energy Solutions18V27/38-GS-60Hz 6,120 kW MAN Energy Solutions18V32/40-GS-50Hz 8,100 kW MAN Energy Solutions18V32/40-GS-60Hz 8,100 kW MAN Energy Solutions18V32/44CR-GS-50Hz 8,640 kW MAN Energy Solutions18V32/44CR-GS-60Hz 8,640 kW MAN Energy Solutions18V35/44DF-GS-50Hz 9,720 kW MAN Energy Solutions18V35/44DF-GS-60Hz 9,720 kW MAN Energy Solutions18V51/60DF-GS-50Hz 20,700 kW MAN Energy Solutions18V51/60DF-GS-60Hz 20,700 kW MAN Energy Solutions20V35/44DF-GS-50Hz 10,800 kW MAN Energy Solutions20V35/44DF-GS-60Hz 10,800 kW MAN Energy Solutions20V51/60DF-GS-50Hz 23,000 kW MAN Energy Solutions20V51/60DF-GS-60Hz 23,000 kW MAN Energy Solutions32/44CR 4,060 kW MAN Energy Solutions35/44 DF 3,060 kW MAN Energy Solutions5L16/24-GS-50Hz 450 kW MAN Energy Solutions5L16/24-GS-60Hz 500 kW MAN Energy Solutions5L21/31-GS-50Hz 1,000 kW MAN Energy Solutions5L21/31-GS-60Hz 1,000 kW MAN Energy Solutions5L21/31DF-GS-50Hz 925 kW MAN Energy Solutions5L21/31DF-GS-60Hz 925 kW MAN Energy Solutions5L23/30H-GS-50Hz 925 kW MAN Energy Solutions5L23/30H-GS-60Hz 925 kW MAN Energy Solutions5L27/38-GS-50Hz 1,700 kW MAN Energy Solutions5L27/38-GS-60Hz 1,700 kW MAN Energy Solutions5L28/32H-GS-50Hz 1,100 kW MAN Energy Solutions5L28/32H-GS-60Hz 1,050 kW MAN Energy Solutions5L28/33D-GS-50Hz 1,600 kW MAN Energy Solutions5L28/33D-GS-60Hz 1,600 kW MAN Energy Solutions6L16/24-GS-50Hz 570 kW MAN Energy Solutions6L16/24-GS-60Hz 660 kW MAN Energy Solutions6L21/31-GS-50Hz 1,200 kW MAN Energy Solutions6L21/31-GS-60Hz 1,200 kW MAN Energy Solutions6L21/31DF-GS-50Hz 1,110 kW MAN Energy Solutions6L21/31DF-GS-60Hz 1,110 kW MAN Energy Solutions6L23/30H-GS-50Hz 1,110 kW MAN Energy Solutions6L23/30H-GS-60Hz 1,110 kW MAN Energy Solutions6L27/38-GS-50Hz 2,040 kW MAN Energy Solutions6L27/38-GS-60Hz 2,040 kW MAN Energy Solutions6L28/32H-GS-50Hz 1,320 kW MAN Energy Solutions6L28/32H-GS-60Hz 1,260 kW MAN Energy Solutions6L28/33D-GS-50Hz 1,920 kW MAN Energy Solutions6L28/33D-GS-60Hz 1,920 kW
By manufacturer

Manufacturers.

All 88 manufacturers with models of Auxiliary Engine (Generator Set). Names with a manufacturer page open it; the others open a search across the full library.

All manufacturers in the library
Show all 88 manufacturers
Related types

Also in Auxiliary Engines.

The other equipment types in this category.

Auxiliary EngineLifeboat EngineMarine Fuel Cell System

Inspection findings for this equipment

From public port state control and US Coast Guard records; OceanSphere assigns them to this equipment type from the descriptions.

Deficiency codes – USCG port state control – foreign-flag vessels

USCG components

All inspection & safety data ›

More than the data sheet shows

Write to us about your machine — the answer comes by e-mail.

Name the make and the model and what the job is: a spare, a service call, a second opinion on a data sheet. We answer by e-mail.

No details at hand? A photo of the rating plate or the part is enough — simply attach it to the request.

Frequently asked

Questions that come up with this equipment.

Is Auxiliary Engine (Generator Set) data free?

Yes. Every model page, every guide and every datasheet for this type is readable without an account. An account adds saved searches and requests, nothing is taken away.

My model is missing — what now?

Send us the nameplate. We identify it by hand, add it to the library, and if you need a part or a service, the request is already on our desk.

Can you source a Auxiliary Engine (Generator Set) part?

Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.