18V35/44DF-GS-60Hz
The MAN 18V35/44DF‑GS‑60Hz is an 18‑cylinder V‑type, dual‑fuel (LNG/HFO) auxiliary engine delivering up to 9 720 kW (≈9.2 MW) at 900 rpm and directly driving a 60 Hz generator set.
Engine Specifications
Components & Design
Component data being added…
Technical Data
🤖 Ask about this model
One free question — answered like a marine engineer. No account needed.
Common failures & inspection points
Monitor exhaust methane concentrations; inspect valve timing; verify adaptive combustion control (ACC) system calibration
Review engine load profiles during dredger/auxiliary duty; check fuel-gas methane number (spec ≥70 MN); monitor combustion pressure transients
Inspect crankcase ventilation filter; check scavenging air receiver for oil/liquid accumulation; monitor crankcase pressure during fuel transitions
Periodic fuel nozzle inspection; relief valve pressure setting verification; fuel system cleanliness monitoring
Monitor turbocharger oil outlet temperature; inspect bearing clearance during scheduled maintenance; verify steady oil-supply pressure under transient load
Type-general inspection and maintenance points for this equipment category — not model-specific.
Suppliers & Spare Parts
Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.
📄 Request sourcing links & documentsCases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.
Start free trial →Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.