Skip to content
OceanSphereDEENPL
OceanSphereENGINES
Library› HVAC› Water Treatment› Mineral Dosing System
Water Treatment

Mineral Dosing System

A mineral dosing system adds calcium and magnesium back into water made by a reverse osmosis or evaporator plant, since the process that removes salt also strips out minerals that give water an acceptable taste and stop it from being aggressively corrosive to pipework.

11models
Sasakura
Knowledge

What to check on a Mineral Dosing System.

11 models from Sasakura in Mineral Dosing System. Below: the full model list.

What makes this type distinct

Fresh water made by reverse osmosis or evaporation on board a ship is essentially demineralised - the same process that removes salt also strips out calcium, magnesium and other minerals naturally present in shore water supplies. That water is flat-tasting and, more importantly, aggressive: it readily leaches metal from copper and galvanised piping because it has no mineral buffer to satisfy its chemical appetite. A mineral dosing system corrects this after the water maker, adding back calcium and magnesium in controlled amounts so the water tastes normal and stops attacking the ship's pipework, unlike disinfection systems such as UV or chlorine dosing, which address bacteria rather than mineral content.

Mineral dosing system flow
Flow diagram of a mineral dosing system showing product water from the reverse osmosis plant being dosed from a mineral solution tank by a dosing pump, blended in a static mixer, checked by a conductivity and pH sensor, and delivered to the potable water tank.

Main components

Dosing media or chemical feed

Either a bed of calcium carbonate or a similar mineral media that the water passes through and slowly dissolves into, or a metered chemical dosing pump injecting a calcium/magnesium solution directly into the flow.

Contact vessel

Where a media bed is used, a pressure vessel giving the water enough contact time and flow distribution to pick up minerals evenly, avoiding channelling that leaves some water under-treated.

Read the full guide

Dosing pump and controller

For chemical dosing systems, a metering pump controlled against flow rate or a hardness sensor, so dosing tracks actual water demand rather than running at a fixed rate regardless of consumption.

Monitoring

Hardness or conductivity monitoring downstream of dosing to confirm the treated water is within the target range, sometimes linked to an alarm if dosing drifts out of range.

Media replenishment

Access port or hopper for topping up mineral media as it is consumed, sized against expected water production to set a practical replenishment interval.

Selection and sizing

Dosing capacity is matched to the water maker's production rate, since undersized dosing leaves peak production periods under-treated even if average output is covered. Media-bed systems suit vessels wanting a simpler, chemical-free system with lower control complexity; metered chemical dosing suits vessels needing tighter, adjustable control of final mineral content, for instance to match a target hardness range rather than whatever the media happens to deliver. Target mineral content is generally set to bring water within a range considered non-aggressive to piping and acceptable for taste, rather than to a single fixed point.

  • Flow rate capacity against the water maker's peak production, not just average output
  • Media-bed versus metered chemical dosing, based on desired control precision
  • Target hardness or mineral range for the ship's piping materials and crew preference
  • Monitoring and alarm capability to catch under- or over-dosing
  • Media or chemical replenishment interval against realistic stores access

Regulations and class

Mineral dosing sits within the broader potable water quality requirements that apply under SOLAS and flag administration rules, which set safe limits for the water crew and passengers drink but generally do not mandate a specific mineral dosing method - the requirement is that the water delivered at the tap meets potable quality, and correcting aggressive, demineralised water is one of the practical ways to protect the piping that carries it there. Class societies typically treat the dosing unit as part of the fresh water generation and distribution system surveyed for general condition rather than as a standalone certified component, unless it is combined with disinfection equipment that does carry its own approval.

Typical faults

FaultConsequence
Media bed exhausted and not replenishedWater reverts to aggressive, undermineralised condition, pipe corrosion resumes
Dosing pump miscalibrated or airlockedUnder-dosing leaves water aggressive; over-dosing wastes chemical and can affect taste
Channelling through the contact vesselUneven treatment, some water passes with little mineral pickup
Hardness monitor not calibrated or checkedDosing drift goes undetected until pipework damage or complaints appear
Media bed not backwashed on scheduleFouling and channelling, reduced effective contact time

What to look for in a supplier

  • Sizing calculation matched to the vessel's actual water maker output, not a generic model
  • Media or chemical grade suited to potable water use with supporting documentation
  • Reliable local or remote monitoring so dosing drift is caught before it causes pipe damage
  • Realistic media consumption figures against production volume, to plan replenishment logistics
  • Compatibility with any UV or chlorine disinfection already fitted downstream or upstream

Test water hardness at the tap periodically, not just at the dosing system outlet - a media bed that channels can pass a spot check right after the unit while still delivering under-treated water to the far end of the distribution line.

By manufacturer

Manufacturers.

All 10 manufacturers with models of Mineral Dosing System. Names with a manufacturer page open it; the others open a search across the full library.

All manufacturers
Would you like to know more?

One request. A person reads it and replies by e-mail.

Tell us the manufacturer, the model and what you need — a part, a service call, a second opinion. A person reads every request and replies by e-mail.

No details at hand? A photo of the rating plate or the part is enough — simply attach it to the request.

Frequently asked

Three things people ask first.

Is Mineral Dosing System data free?

Yes. Every model page, every guide and every datasheet for this type is readable without an account. An account adds saved searches and requests, nothing is taken away.

My model is missing — what now?

Send us the nameplate. We identify it by hand, add it to the library, and if you need a part or a service, the request is already on our desk.

Can you source a Mineral Dosing System part?

Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.