UV treatment inactivates organisms in ballast water by damaging their DNA under ultraviolet light rather than killing them outright, which is why UV systems live and die by water clarity rather than by chemical dose.

213models
Alfa Laval
Knowledge

What to check on a UV-Based BWMS.

213 models from Alfa Laval in UV-Based BWMS. Below: the full model list.

What sets UV treatment apart

A UV-based ballast water management system passes ballast water through a reactor chamber lined with UV lamps that damage the DNA of organisms so they cannot reproduce, rather than killing them outright the way a biocide or electrochlorination system does. Because UV works by line-of-sight exposure through the water column, its performance depends directly on how much light actually reaches the organism — turbidity, suspended solids and biofouling on the lamp sleeves all cut effective dose, which is the main reason UV systems are paired with a filtration stage rather than sold as UV alone.

UV-based ballast water treatment system
Flow diagram of a UV ballast water treatment system showing the filter, the UV reactor with lamps in quartz sleeves, the UV intensity sensor and the path from inlet to the ballast tanks.

Legend

  1. monitoring and control
  2. filter
  3. UV reactor chamber
  4. UV lamps in quartz sleeves
  5. to ballast tanks
  6. ballast water inlet
  7. UV intensity sensor

Main components

Filter

A self-cleaning screen or disc filter, typically 20 to 50 micron, that strips out sediment, plankton and debris before the UV reactor so the remaining organisms are exposed to full-strength light.

UV reactor

A chamber holding banks of medium or low-pressure UV lamps in quartz sleeves, sized so every litre passing through receives the minimum dose the system was type-approved for at the vessel's rated flow.

Read the full guide

UV intensity sensors

Sensors that monitor light transmission through the water in real time and signal the control system to reduce flow or raise an alarm if dose falls below the approved threshold.

Control and monitoring unit

Logs treatment records for port state control and IMO compliance, and interlocks the ballast pumps so water cannot bypass the reactor.

Selection / Sizing

  • Ballast pump flow rate, since the reactor must treat the full rated flow within its type-approved UV dose — undersizing the reactor for the pump forces a flow restriction that slows ballasting operations.
  • Typical water turbidity for the vessel's trading pattern; a ship regularly ballasting in silty coastal or river water needs a more robust filter stage than one loading in open ocean.
  • Lamp type and expected lamp life, since medium-pressure lamps run hotter and shorter but treat higher flows in a smaller footprint than low-pressure lamps.
  • Space and power available, as UV systems draw meaningful electrical load and need a straight reactor run without tight bends.

Regulations / Class

Every seagoing ship has been required to carry an operational ballast water management system under the IMO BWM Convention since the 2024 compliance deadline, and the treatment system itself must hold IMO type approval (or USCG approval for US waters) confirming it meets the D-2 discharge standard for organism concentration. Class surveys check that treatment records are logged for every ballasting operation and that the system's approval certificate matches the installed configuration, including any approved operating envelope for turbidity or salinity.

Typical faults

FaultCauseConsequence
Dose alarm during ballastingHigh turbidity exceeding the system's approved operating rangeBallast operation slows or stops until water clarity improves
Reduced UV transmissionBiofouling or scaling on the quartz lamp sleevesEffective dose drops even though lamps show as functioning
Filter backwash failureScreen clogged faster than the automatic flush cycle clears itFlow restriction forces reduced ballast pump throughput
Lamp failure undetectedLamp ballast fault not cross-checked against intensity sensor readingWater passes with an under-treated dose without an alarm

What to look for in a supplier

  • IMO type approval covering the actual flow rate and turbidity range the vessel will operate in, not just the headline capacity.
  • Spare lamp and quartz sleeve availability at ports the vessel actually calls, since UV lamps are a wear item with a finite rated life.
  • A service network able to recalibrate UV intensity sensors, which drift over time and are easy to overlook during routine maintenance.

A UV system logging a compliant dose in clear open-ocean water can still fail the same voyage in a silty river estuary — check the type-approval turbidity envelope against the vessel's actual ports before assuming coverage.

Models

Models in this type.

The best-documented model of each manufacturer first, then the next — 100 of 213 models in UV-Based BWMS. Every row links to full specifications, documents and service notes.

Showing only Alfa Laval. Show all manufacturers
Alfa LavalPureBallast 3.1 Compact 250 m³/h Alfa LavalPureBallast 3.1 Ex 1000 1000 m³/h Alfa LavalPureBallast 3.1 Ex 1500 1500 m³/h Alfa LavalPureBallast 3.1 Ex 2500 2500 m³/h Alfa LavalPureBallast 3.1 Ex 300 300 m³/h Alfa LavalPureBallast 3.1 Ex 3000 3000 m³/h Alfa LavalPureBallast 3.1 Ex 500 500 m³/h Alfa LavalPureBallast 3.1 Ex 750 750 m³/h Alfa LavalPureBallast 3.1 1000m3h 50 kW Alfa LavalPureBallast 3.1 1500m3h 75 kW Alfa LavalPureBallast 3.1 150m3h 7.5 kW Alfa LavalPureBallast 3.1 2000m3h 100 kW Alfa LavalPureBallast 3.1 2500m3h 125 kW Alfa LavalPureBallast 3.1 250m3h 12.5 kW Alfa LavalPureBallast 3.1 3000m3h 150 kW Alfa LavalPureBallast 3.1 300m3h 15 kW Alfa LavalPureBallast 3.1 4000m3h 200 kW Alfa LavalPureBallast 3.1 5000m3h 250 kW Alfa LavalPureBallast 3.1 500m3h 25 kW Alfa LavalPureBallast 3.1 6000m3h 300 kW Alfa LavalPureBallast 3.1 750m3h 37.5 kW Alfa LavalPureBallast 3.1 Compact 1000m3h 50 kW Alfa LavalPureBallast 3.1 Compact 1500m3h 75 kW Alfa LavalPureBallast 3.1 Compact 150m3h 7.5 kW Alfa LavalPureBallast 3.1 Compact 2000m3h 100 kW Alfa LavalPureBallast 3.1 Compact 2500m3h 125 kW Alfa LavalPureBallast 3.1 Compact 250m3h 12.5 kW Alfa LavalPureBallast 3.1 Compact 3000m3h 150 kW Alfa LavalPureBallast 3.1 Compact 300m3h 15 kW Alfa LavalPureBallast 3.1 Compact 4000m3h 200 kW Alfa LavalPureBallast 3.1 Compact 5000m3h 250 kW Alfa LavalPureBallast 3.1 Compact 500m3h 25 kW Alfa LavalPureBallast 3.1 Compact 6000m3h 300 kW Alfa LavalPureBallast 3.1 Compact 750m3h 37.5 kW Alfa LavalPureBallast 3.1 Ex 1000m3h 50 kW Alfa LavalPureBallast 3.1 Ex 1500m3h 75 kW Alfa LavalPureBallast 3.1 Ex 150m3h 7.5 kW Alfa LavalPureBallast 3.1 Ex 2000m3h 100 kW Alfa LavalPureBallast 3.1 Ex 2500m3h 125 kW Alfa LavalPureBallast 3.1 Ex 250m3h 12.5 kW Alfa LavalPureBallast 3.1 Ex 3000m3h 150 kW Alfa LavalPureBallast 3.1 Ex 300m3h 15 kW Alfa LavalPureBallast 3.1 Ex 4000m3h 200 kW Alfa LavalPureBallast 3.1 Ex 5000m3h 250 kW Alfa LavalPureBallast 3.1 Ex 500m3h 25 kW Alfa LavalPureBallast 3.1 Ex 6000m3h 300 kW Alfa LavalPureBallast 3.1 Ex 750m3h 37.5 kW Alfa LavalPureBallast 3.2 1000m3h 50 kW Alfa LavalPureBallast 3.2 1500m3h 75 kW Alfa LavalPureBallast 3.2 150m3h 7.5 kW Alfa LavalPureBallast 3.2 2000m3h 100 kW Alfa LavalPureBallast 3.2 2500m3h 125 kW Alfa LavalPureBallast 3.2 250m3h 12.5 kW Alfa LavalPureBallast 3.2 3000m3h 150 kW Alfa LavalPureBallast 3.2 300m3h 15 kW Alfa LavalPureBallast 3.2 4000m3h 200 kW Alfa LavalPureBallast 3.2 5000m3h 250 kW Alfa LavalPureBallast 3.2 500m3h 25 kW Alfa LavalPureBallast 3.2 6000m3h 300 kW Alfa LavalPureBallast 3.2 750m3h 37.5 kW Alfa LavalUV BWMS 10000m3h ABS-approved 500 kW Alfa LavalUV BWMS 10000m3h BV-approved 500 kW Alfa LavalUV BWMS 10000m3h DNV-approved 500 kW Alfa LavalUV BWMS 10000m3h LR-approved 500 kW Alfa LavalUV BWMS 1000m3h ABS-approved 50 kW Alfa LavalUV BWMS 1000m3h BV-approved 50 kW Alfa LavalUV BWMS 1000m3h DNV-approved 50 kW Alfa LavalUV BWMS 1000m3h LR-approved 50 kW Alfa LavalUV BWMS 100m3h ABS-approved 5 kW Alfa LavalUV BWMS 100m3h BV-approved 5 kW Alfa LavalUV BWMS 100m3h DNV-approved 5 kW Alfa LavalUV BWMS 100m3h LR-approved 5 kW Alfa LavalUV BWMS 1250m3h ABS-approved 62.5 kW Alfa LavalUV BWMS 1250m3h BV-approved 62.5 kW Alfa LavalUV BWMS 1250m3h DNV-approved 62.5 kW Alfa LavalUV BWMS 1250m3h LR-approved 62.5 kW Alfa LavalUV BWMS 1500m3h ABS-approved 75 kW Alfa LavalUV BWMS 1500m3h BV-approved 75 kW Alfa LavalUV BWMS 1500m3h DNV-approved 75 kW Alfa LavalUV BWMS 1500m3h LR-approved 75 kW Alfa LavalUV BWMS 150m3h ABS-approved 7.5 kW Alfa LavalUV BWMS 150m3h BV-approved 7.5 kW Alfa LavalUV BWMS 150m3h DNV-approved 7.5 kW Alfa LavalUV BWMS 150m3h LR-approved 7.5 kW Alfa LavalUV BWMS 2000m3h ABS-approved 100 kW Alfa LavalUV BWMS 2000m3h BV-approved 100 kW Alfa LavalUV BWMS 2000m3h DNV-approved 100 kW Alfa LavalUV BWMS 2000m3h LR-approved 100 kW Alfa LavalUV BWMS 200m3h ABS-approved 10 kW Alfa LavalUV BWMS 200m3h BV-approved 10 kW Alfa LavalUV BWMS 200m3h DNV-approved 10 kW Alfa LavalUV BWMS 200m3h LR-approved 10 kW Alfa LavalUV BWMS 2500m3h ABS-approved 125 kW Alfa LavalUV BWMS 2500m3h BV-approved 125 kW Alfa LavalUV BWMS 2500m3h DNV-approved 125 kW Alfa LavalUV BWMS 2500m3h LR-approved 125 kW Alfa LavalUV BWMS 250m3h ABS-approved 12.5 kW Alfa LavalUV BWMS 250m3h BV-approved 12.5 kW Alfa LavalUV BWMS 250m3h DNV-approved 12.5 kW Alfa LavalUV BWMS 250m3h LR-approved 12.5 kW
Related types

Also in Ballast Water Treatment Systems.

The other equipment types in this category.

Electrochlorination BWMSElectrolysis BWTSFilter + UV BWMSOzone-Based BWMSUV-Based BWTS
Would you like to know more?

One request. A person reads it and replies by e-mail.

Tell us the manufacturer, the model and what you need — a part, a service call, a second opinion. A person reads every request and replies by e-mail.

No details at hand? A photo of the rating plate or the part is enough — simply attach it to the request.

Frequently asked

Three things people ask first.

Is UV-Based BWMS data free?

Yes. Every model page, every guide and every datasheet for this type is readable without an account. An account adds saved searches and requests, nothing is taken away.

My model is missing — what now?

Send us the nameplate. We identify it by hand, add it to the library, and if you need a part or a service, the request is already on our desk.

Can you source a UV-Based BWMS part?

Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.