OceanSphere
Engines

Screw Pump

medium 456 models total

A screw pump moves fuel and lube oil with meshing helical rotors instead of gears or vanes, giving a smooth, low-pulsation flow that tolerates the viscosity swings of heavy fuel far better than a gear pump of the same duty.

Read more — Screw Pump explained

What sets a screw pump apart

A screw pump is a positive displacement pump that moves liquid axially along meshing helical rotors (typically one power rotor driving one or two idler rotors) instead of trapping it between gear teeth or sliding vanes. The rotor geometry gives an almost pulsation-free, continuous flow, which matters for fuel injection supply and transfer duties where pressure spikes cause noise and wear elsewhere in the system. Compared with a gear pump, a screw pump tolerates a wider viscosity range with less efficiency loss, which is why it is the standard choice for heavy fuel oil (HFO) transfer and supply, where viscosity can swing several hundred centistokes between a cold start and normal running temperature. Screw pumps also run quieter and with less shaft vibration than gear or vane types at the same flow and pressure, an advantage in engine rooms with pumps mounted close to accommodation spaces.

Three-screw pump, rotor arrangement
Cutaway of a three-screw pump showing the central power rotor meshing with two idler rotors inside the housing liner, the driven shaft with its seal, the suction and discharge ports, and the internal relief valve.

Main components

Power rotor and idler rotor(s)

The power rotor is driven directly by the motor; idler rotors mesh with it and are turned only by the fluid film and rotor contact, not by a separate gear train in most designs, which keeps the pump simple and reduces parts subject to wear.

Housing / stator

Precision-bored housing that the rotors run in with close clearance; this clearance is what determines volumetric efficiency and how much internal slip, and therefore capacity loss, occurs at a given viscosity.

Mechanical seal or packed gland

Seals the shaft where it passes through the housing; mechanical seals dominate on modern fuel and lube oil screw pumps for tighter leak control.

Relief valve

Fitted internally or on the discharge line, since a positive displacement pump will build pressure indefinitely against a closed valve and must have a path to relieve it.

Selection and sizing

  • Viscosity range - the single most important selection parameter for fuel duty; the pump must maintain rated flow across the full range from cold-start to operating temperature.
  • Differential pressure - fuel supply pumps typically run at several bar; boosting or circulating pumps in HFO systems can run higher against injection system back-pressure.
  • NPSH available - suction conditions from the service tank, especially on transfer duty pulling from a nearly empty tank.
  • Rotor material and clearance - tighter clearances raise volumetric efficiency but reduce tolerance to solids or wear debris in the fluid.

Regulations and class

Fuel oil supply and transfer pumps fall under the classification society's machinery rules for essential auxiliary systems, which typically require duplication of fuel supply pumps to the main engine so a single pump failure does not stop propulsion. Class also reviews the relief valve setting and pressure rating of the pump and its piping as part of the fuel system approval. There is no IMO instrument specific to screw pumps; requirements apply to the fuel and lube oil systems they serve, under MARPOL Annex I for oil-handling arrangements and under class rules for redundancy of essential services.

Typical faults

FaultConsequence
Rotor and housing wear (increased clearance)falling volumetric efficiency, especially noticeable on light, low-viscosity fuel
Mechanical seal failurefuel or oil leakage at the shaft, a fire and slip hazard in the engine room
Relief valve stuck or incorrectly seteither nuisance recirculation losing capacity, or overpressure of piping if stuck shut
Cavitation on suctionnoise, rotor pitting and falling output, usually from a restricted suction line or a nearly empty tank

What to look for in a supplier

  • Published performance curves across the actual viscosity range the fuel or oil will see in service, not just at a single reference viscosity.
  • Rotor and housing material suited to the fluid, including compatibility with low-sulphur and biofuel blends now common in fuel systems.
  • Spare rotor sets and seal kits genuinely available for the model, since screw pump rotors are precision parts not produced by third parties.

A screw pump that loses capacity is almost always wear, not a blockage - rising slip through worn rotor clearance shows up first as reduced flow at normal running temperature, well before any alarm trips.

Technical drawings & plates

Historical engineering archive — public domain sources, cited per plate. Principles shown remain valid; always consult the OEM manual for model-specific data.

Double-screw low-pitch pump.
Double-screw low-pitch pump.
Boilerman 3 & 2, NAVPERS 10535-C, U.S. Navy (1955) — public domain
Cutaway view of triple-screw high-pitch pump.
Cutaway view of triple-screw high-pitch pump.
Boilerman 3 & 2, NAVPERS 10535-C, U.S. Navy (1955) — public domain
Dismantled triple-screw high-pitch pump.
Dismantled triple-screw high-pitch pump.
Boilerman 3 & 2, NAVPERS 10535-C, U.S. Navy (1955) — public domain
Cutaway view of triple-screw high-pitch pump.
Cutaway view of triple-screw high-pitch pump.
Engineman 2, NAVPERS 10540, U.S. Navy (1957) — public domain

16 manufacturers · 456 models

IMO Pump

15 ✓ 15 verified
IMO Pump Series 3D
Series 3D ✓ verified
Application
General purpose: lubrication, fuel transport and burner service, low pressure hydraulic applications, hydraulic elevator service
Common Failures & Inspection Points
  • Area: Rotor-to-rotor und Rotor-zu-Gehäuse Spieldimension mit Messuhr überprüfen und gegen OEM-Verschleißgrenzwerte vergleichen (Messung mit Lehren durchführen)
    Check: Rotor-to-rotor und Rotor-zu-Gehäuse Spieldimension mit Messuhr überprüfen und gegen OEM-Verschleißgrenzwerte vergleichen (Messung mit Lehren durchführen)
  • Area: Mechanische Wellendichtung und Gasketdichtheit prüfen: Auf Lecks, Risse, Verfärbungen oder Verhärtung prüfen; Verschleiß von Dichtringflächen inspizieren
    Check: Mechanische Wellendichtung und Gasketdichtheit prüfen: Auf Lecks, Risse, Verfärbungen oder Verhärtung prüfen; Verschleiß von Dichtringflächen inspizieren
  • Area: Gehäusebohrung, Rotoroberflächen und Deckelplatte auf Kratzspuren, Korrosionspitting oder Oberflächenverschleiß kontrollieren (Reinigungsfähigkeit prüfen)
    Check: Gehäusebohrung, Rotoroberflächen und Deckelplatte auf Kratzspuren, Korrosionspitting oder Oberflächenverschleiß kontrollieren (Reinigungsfähigkeit prüfen)
  • Area: Lager und Lagerspiele kontrollieren: Radialspiel und Axialspiel mit geeigneten Messinstrumenten überprüfen; auf Verschleiß und Erhitzung hinweisen
    Check: Lager und Lagerspiele kontrollieren: Radialspiel und Axialspiel mit geeigneten Messinstrumenten überprüfen; auf Verschleiß und Erhitzung hinweisen
  • Area: Druckentlastungsventil und Überdruckschutz funktional testen; Einstellwerte gegen Herstellervorgabe überprüfen
    Check: Druckentlastungsventil und Überdruckschutz funktional testen; Einstellwerte gegen Herstellervorgabe überprüfen
  • Area: Saugsieb und Einlassfilter auf Verschmutzung und Blockierung kontrollieren; Druckabfall über Filter überwachen
    Check: Saugsieb und Einlassfilter auf Verschmutzung und Blockierung kontrollieren; Druckabfall über Filter überwachen
  • Area: Betriebsgeräusche, Vibrationen und ungewöhnliche Sounds diagnostizieren (Hinweis auf innere Verschleißmuster)
    Check: Betriebsgeräusche, Vibrationen und ungewöhnliche Sounds diagnostizieren (Hinweis auf innere Verschleißmuster)
  • Area: Befestigungselemente, Befestigungsschrauben und Kupplungsausrichtung überprüfen; Ausrichtung Pumpe-Motor/Antrieb nachmessen
    Check: Befestigungselemente, Befestigungsschrauben und Kupplungsausrichtung überprüfen; Ausrichtung Pumpe-Motor/Antrieb nachmessen

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

IMO Pump Series 3E
Series 3E ✓ verified
Application
Fuel oil transfer, machinery lubrication, general industrial pumping
Common Failures & Inspection Points
  • Area: Rotor-to-rotor und Rotor-zu-Gehäuse Spieldimension mit Messuhr überprüfen und gegen OEM-Verschleißgrenzwerte vergleichen (Messung mit Lehren durchführen)
    Check: Rotor-to-rotor und Rotor-zu-Gehäuse Spieldimension mit Messuhr überprüfen und gegen OEM-Verschleißgrenzwerte vergleichen (Messung mit Lehren durchführen)
  • Area: Mechanische Wellendichtung und Gasketdichtheit prüfen: Auf Lecks, Risse, Verfärbungen oder Verhärtung prüfen; Verschleiß von Dichtringflächen inspizieren
    Check: Mechanische Wellendichtung und Gasketdichtheit prüfen: Auf Lecks, Risse, Verfärbungen oder Verhärtung prüfen; Verschleiß von Dichtringflächen inspizieren
  • Area: Gehäusebohrung, Rotoroberflächen und Deckelplatte auf Kratzspuren, Korrosionspitting oder Oberflächenverschleiß kontrollieren (Reinigungsfähigkeit prüfen)
    Check: Gehäusebohrung, Rotoroberflächen und Deckelplatte auf Kratzspuren, Korrosionspitting oder Oberflächenverschleiß kontrollieren (Reinigungsfähigkeit prüfen)
  • Area: Lager und Lagerspiele kontrollieren: Radialspiel und Axialspiel mit geeigneten Messinstrumenten überprüfen; auf Verschleiß und Erhitzung hinweisen
    Check: Lager und Lagerspiele kontrollieren: Radialspiel und Axialspiel mit geeigneten Messinstrumenten überprüfen; auf Verschleiß und Erhitzung hinweisen
  • Area: Druckentlastungsventil und Überdruckschutz funktional testen; Einstellwerte gegen Herstellervorgabe überprüfen
    Check: Druckentlastungsventil und Überdruckschutz funktional testen; Einstellwerte gegen Herstellervorgabe überprüfen
  • Area: Saugsieb und Einlassfilter auf Verschmutzung und Blockierung kontrollieren; Druckabfall über Filter überwachen
    Check: Saugsieb und Einlassfilter auf Verschmutzung und Blockierung kontrollieren; Druckabfall über Filter überwachen
  • Area: Betriebsgeräusche, Vibrationen und ungewöhnliche Sounds diagnostizieren (Hinweis auf innere Verschleißmuster)
    Check: Betriebsgeräusche, Vibrationen und ungewöhnliche Sounds diagnostizieren (Hinweis auf innere Verschleißmuster)
  • Area: Befestigungselemente, Befestigungsschrauben und Kupplungsausrichtung überprüfen; Ausrichtung Pumpe-Motor/Antrieb nachmessen
    Check: Befestigungselemente, Befestigungsschrauben und Kupplungsausrichtung überprüfen; Ausrichtung Pumpe-Motor/Antrieb nachmessen

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

IMO Pump Series 3G
Series 3G ✓ verified
Application
Lubrication, hydraulic and control oil services
Common Failures & Inspection Points
  • Area: Rotor-to-rotor und Rotor-zu-Gehäuse Spieldimension mit Messuhr überprüfen und gegen OEM-Verschleißgrenzwerte vergleichen (Messung mit Lehren durchführen)
    Check: Rotor-to-rotor und Rotor-zu-Gehäuse Spieldimension mit Messuhr überprüfen und gegen OEM-Verschleißgrenzwerte vergleichen (Messung mit Lehren durchführen)
  • Area: Mechanische Wellendichtung und Gasketdichtheit prüfen: Auf Lecks, Risse, Verfärbungen oder Verhärtung prüfen; Verschleiß von Dichtringflächen inspizieren
    Check: Mechanische Wellendichtung und Gasketdichtheit prüfen: Auf Lecks, Risse, Verfärbungen oder Verhärtung prüfen; Verschleiß von Dichtringflächen inspizieren
  • Area: Gehäusebohrung, Rotoroberflächen und Deckelplatte auf Kratzspuren, Korrosionspitting oder Oberflächenverschleiß kontrollieren (Reinigungsfähigkeit prüfen)
    Check: Gehäusebohrung, Rotoroberflächen und Deckelplatte auf Kratzspuren, Korrosionspitting oder Oberflächenverschleiß kontrollieren (Reinigungsfähigkeit prüfen)
  • Area: Lager und Lagerspiele kontrollieren: Radialspiel und Axialspiel mit geeigneten Messinstrumenten überprüfen; auf Verschleiß und Erhitzung hinweisen
    Check: Lager und Lagerspiele kontrollieren: Radialspiel und Axialspiel mit geeigneten Messinstrumenten überprüfen; auf Verschleiß und Erhitzung hinweisen
  • Area: Druckentlastungsventil und Überdruckschutz funktional testen; Einstellwerte gegen Herstellervorgabe überprüfen
    Check: Druckentlastungsventil und Überdruckschutz funktional testen; Einstellwerte gegen Herstellervorgabe überprüfen
  • Area: Saugsieb und Einlassfilter auf Verschmutzung und Blockierung kontrollieren; Druckabfall über Filter überwachen
    Check: Saugsieb und Einlassfilter auf Verschmutzung und Blockierung kontrollieren; Druckabfall über Filter überwachen
  • Area: Betriebsgeräusche, Vibrationen und ungewöhnliche Sounds diagnostizieren (Hinweis auf innere Verschleißmuster)
    Check: Betriebsgeräusche, Vibrationen und ungewöhnliche Sounds diagnostizieren (Hinweis auf innere Verschleißmuster)
  • Area: Befestigungselemente, Befestigungsschrauben und Kupplungsausrichtung überprüfen; Ausrichtung Pumpe-Motor/Antrieb nachmessen
    Check: Befestigungselemente, Befestigungsschrauben und Kupplungsausrichtung überprüfen; Ausrichtung Pumpe-Motor/Antrieb nachmessen

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

IMO Pump Series 3L (E3L)
Series 3L (E3L) ✓ verified
Application
Lubrication services in industrial, oil and gas, power generation, and lubrication systems
Common Failures & Inspection Points
  • Area: Rotor-to-rotor und Rotor-zu-Gehäuse Spieldimension mit Messuhr überprüfen und gegen OEM-Verschleißgrenzwerte vergleichen (Messung mit Lehren durchführen)
    Check: Rotor-to-rotor und Rotor-zu-Gehäuse Spieldimension mit Messuhr überprüfen und gegen OEM-Verschleißgrenzwerte vergleichen (Messung mit Lehren durchführen)
  • Area: Mechanische Wellendichtung und Gasketdichtheit prüfen: Auf Lecks, Risse, Verfärbungen oder Verhärtung prüfen; Verschleiß von Dichtringflächen inspizieren
    Check: Mechanische Wellendichtung und Gasketdichtheit prüfen: Auf Lecks, Risse, Verfärbungen oder Verhärtung prüfen; Verschleiß von Dichtringflächen inspizieren
  • Area: Gehäusebohrung, Rotoroberflächen und Deckelplatte auf Kratzspuren, Korrosionspitting oder Oberflächenverschleiß kontrollieren (Reinigungsfähigkeit prüfen)
    Check: Gehäusebohrung, Rotoroberflächen und Deckelplatte auf Kratzspuren, Korrosionspitting oder Oberflächenverschleiß kontrollieren (Reinigungsfähigkeit prüfen)
  • Area: Lager und Lagerspiele kontrollieren: Radialspiel und Axialspiel mit geeigneten Messinstrumenten überprüfen; auf Verschleiß und Erhitzung hinweisen
    Check: Lager und Lagerspiele kontrollieren: Radialspiel und Axialspiel mit geeigneten Messinstrumenten überprüfen; auf Verschleiß und Erhitzung hinweisen
  • Area: Druckentlastungsventil und Überdruckschutz funktional testen; Einstellwerte gegen Herstellervorgabe überprüfen
    Check: Druckentlastungsventil und Überdruckschutz funktional testen; Einstellwerte gegen Herstellervorgabe überprüfen
  • Area: Saugsieb und Einlassfilter auf Verschmutzung und Blockierung kontrollieren; Druckabfall über Filter überwachen
    Check: Saugsieb und Einlassfilter auf Verschmutzung und Blockierung kontrollieren; Druckabfall über Filter überwachen
  • Area: Betriebsgeräusche, Vibrationen und ungewöhnliche Sounds diagnostizieren (Hinweis auf innere Verschleißmuster)
    Check: Betriebsgeräusche, Vibrationen und ungewöhnliche Sounds diagnostizieren (Hinweis auf innere Verschleißmuster)
  • Area: Befestigungselemente, Befestigungsschrauben und Kupplungsausrichtung überprüfen; Ausrichtung Pumpe-Motor/Antrieb nachmessen
    Check: Befestigungselemente, Befestigungsschrauben und Kupplungsausrichtung überprüfen; Ausrichtung Pumpe-Motor/Antrieb nachmessen

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

IMO Pump Series 6D
Series 6D ✓ verified
Application
Fuel oil burners, high pressure trunion lubrication for ball mills, crude oil pipeline service, non-cyclic hydraulic applications
Common Failures & Inspection Points
  • Area: Rotor-to-rotor und Rotor-zu-Gehäuse Spieldimension mit Messuhr überprüfen und gegen OEM-Verschleißgrenzwerte vergleichen (Messung mit Lehren durchführen)
    Check: Rotor-to-rotor und Rotor-zu-Gehäuse Spieldimension mit Messuhr überprüfen und gegen OEM-Verschleißgrenzwerte vergleichen (Messung mit Lehren durchführen)
  • Area: Mechanische Wellendichtung und Gasketdichtheit prüfen: Auf Lecks, Risse, Verfärbungen oder Verhärtung prüfen; Verschleiß von Dichtringflächen inspizieren
    Check: Mechanische Wellendichtung und Gasketdichtheit prüfen: Auf Lecks, Risse, Verfärbungen oder Verhärtung prüfen; Verschleiß von Dichtringflächen inspizieren
  • Area: Gehäusebohrung, Rotoroberflächen und Deckelplatte auf Kratzspuren, Korrosionspitting oder Oberflächenverschleiß kontrollieren (Reinigungsfähigkeit prüfen)
    Check: Gehäusebohrung, Rotoroberflächen und Deckelplatte auf Kratzspuren, Korrosionspitting oder Oberflächenverschleiß kontrollieren (Reinigungsfähigkeit prüfen)
  • Area: Lager und Lagerspiele kontrollieren: Radialspiel und Axialspiel mit geeigneten Messinstrumenten überprüfen; auf Verschleiß und Erhitzung hinweisen
    Check: Lager und Lagerspiele kontrollieren: Radialspiel und Axialspiel mit geeigneten Messinstrumenten überprüfen; auf Verschleiß und Erhitzung hinweisen
  • Area: Druckentlastungsventil und Überdruckschutz funktional testen; Einstellwerte gegen Herstellervorgabe überprüfen
    Check: Druckentlastungsventil und Überdruckschutz funktional testen; Einstellwerte gegen Herstellervorgabe überprüfen
  • Area: Saugsieb und Einlassfilter auf Verschmutzung und Blockierung kontrollieren; Druckabfall über Filter überwachen
    Check: Saugsieb und Einlassfilter auf Verschmutzung und Blockierung kontrollieren; Druckabfall über Filter überwachen
  • Area: Betriebsgeräusche, Vibrationen und ungewöhnliche Sounds diagnostizieren (Hinweis auf innere Verschleißmuster)
    Check: Betriebsgeräusche, Vibrationen und ungewöhnliche Sounds diagnostizieren (Hinweis auf innere Verschleißmuster)
  • Area: Befestigungselemente, Befestigungsschrauben und Kupplungsausrichtung überprüfen; Ausrichtung Pumpe-Motor/Antrieb nachmessen
    Check: Befestigungselemente, Befestigungsschrauben und Kupplungsausrichtung überprüfen; Ausrichtung Pumpe-Motor/Antrieb nachmessen

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

IMO Pump Series 12D
Series 12D ✓ verified
Application
High pressure service on petroleum and similar viscosity liquids
Common Failures & Inspection Points
  • Area: Rotor-to-rotor und Rotor-zu-Gehäuse Spieldimension mit Messuhr überprüfen und gegen OEM-Verschleißgrenzwerte vergleichen (Messung mit Lehren durchführen)
    Check: Rotor-to-rotor und Rotor-zu-Gehäuse Spieldimension mit Messuhr überprüfen und gegen OEM-Verschleißgrenzwerte vergleichen (Messung mit Lehren durchführen)
  • Area: Mechanische Wellendichtung und Gasketdichtheit prüfen: Auf Lecks, Risse, Verfärbungen oder Verhärtung prüfen; Verschleiß von Dichtringflächen inspizieren
    Check: Mechanische Wellendichtung und Gasketdichtheit prüfen: Auf Lecks, Risse, Verfärbungen oder Verhärtung prüfen; Verschleiß von Dichtringflächen inspizieren
  • Area: Gehäusebohrung, Rotoroberflächen und Deckelplatte auf Kratzspuren, Korrosionspitting oder Oberflächenverschleiß kontrollieren (Reinigungsfähigkeit prüfen)
    Check: Gehäusebohrung, Rotoroberflächen und Deckelplatte auf Kratzspuren, Korrosionspitting oder Oberflächenverschleiß kontrollieren (Reinigungsfähigkeit prüfen)
  • Area: Lager und Lagerspiele kontrollieren: Radialspiel und Axialspiel mit geeigneten Messinstrumenten überprüfen; auf Verschleiß und Erhitzung hinweisen
    Check: Lager und Lagerspiele kontrollieren: Radialspiel und Axialspiel mit geeigneten Messinstrumenten überprüfen; auf Verschleiß und Erhitzung hinweisen
  • Area: Druckentlastungsventil und Überdruckschutz funktional testen; Einstellwerte gegen Herstellervorgabe überprüfen
    Check: Druckentlastungsventil und Überdruckschutz funktional testen; Einstellwerte gegen Herstellervorgabe überprüfen
  • Area: Saugsieb und Einlassfilter auf Verschmutzung und Blockierung kontrollieren; Druckabfall über Filter überwachen
    Check: Saugsieb und Einlassfilter auf Verschmutzung und Blockierung kontrollieren; Druckabfall über Filter überwachen
  • Area: Betriebsgeräusche, Vibrationen und ungewöhnliche Sounds diagnostizieren (Hinweis auf innere Verschleißmuster)
    Check: Betriebsgeräusche, Vibrationen und ungewöhnliche Sounds diagnostizieren (Hinweis auf innere Verschleißmuster)
  • Area: Befestigungselemente, Befestigungsschrauben und Kupplungsausrichtung überprüfen; Ausrichtung Pumpe-Motor/Antrieb nachmessen
    Check: Befestigungselemente, Befestigungsschrauben und Kupplungsausrichtung überprüfen; Ausrichtung Pumpe-Motor/Antrieb nachmessen

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

IMO Pump Series 12L
Series 12L ✓ verified
Application
Very high pressure service for compressor gas sealing, fluid power and hydrostatic bearing applications
Common Failures & Inspection Points
  • Area: Rotor-to-rotor und Rotor-zu-Gehäuse Spieldimension mit Messuhr überprüfen und gegen OEM-Verschleißgrenzwerte vergleichen (Messung mit Lehren durchführen)
    Check: Rotor-to-rotor und Rotor-zu-Gehäuse Spieldimension mit Messuhr überprüfen und gegen OEM-Verschleißgrenzwerte vergleichen (Messung mit Lehren durchführen)
  • Area: Mechanische Wellendichtung und Gasketdichtheit prüfen: Auf Lecks, Risse, Verfärbungen oder Verhärtung prüfen; Verschleiß von Dichtringflächen inspizieren
    Check: Mechanische Wellendichtung und Gasketdichtheit prüfen: Auf Lecks, Risse, Verfärbungen oder Verhärtung prüfen; Verschleiß von Dichtringflächen inspizieren
  • Area: Gehäusebohrung, Rotoroberflächen und Deckelplatte auf Kratzspuren, Korrosionspitting oder Oberflächenverschleiß kontrollieren (Reinigungsfähigkeit prüfen)
    Check: Gehäusebohrung, Rotoroberflächen und Deckelplatte auf Kratzspuren, Korrosionspitting oder Oberflächenverschleiß kontrollieren (Reinigungsfähigkeit prüfen)
  • Area: Lager und Lagerspiele kontrollieren: Radialspiel und Axialspiel mit geeigneten Messinstrumenten überprüfen; auf Verschleiß und Erhitzung hinweisen
    Check: Lager und Lagerspiele kontrollieren: Radialspiel und Axialspiel mit geeigneten Messinstrumenten überprüfen; auf Verschleiß und Erhitzung hinweisen
  • Area: Druckentlastungsventil und Überdruckschutz funktional testen; Einstellwerte gegen Herstellervorgabe überprüfen
    Check: Druckentlastungsventil und Überdruckschutz funktional testen; Einstellwerte gegen Herstellervorgabe überprüfen
  • Area: Saugsieb und Einlassfilter auf Verschmutzung und Blockierung kontrollieren; Druckabfall über Filter überwachen
    Check: Saugsieb und Einlassfilter auf Verschmutzung und Blockierung kontrollieren; Druckabfall über Filter überwachen
  • Area: Betriebsgeräusche, Vibrationen und ungewöhnliche Sounds diagnostizieren (Hinweis auf innere Verschleißmuster)
    Check: Betriebsgeräusche, Vibrationen und ungewöhnliche Sounds diagnostizieren (Hinweis auf innere Verschleißmuster)
  • Area: Befestigungselemente, Befestigungsschrauben und Kupplungsausrichtung überprüfen; Ausrichtung Pumpe-Motor/Antrieb nachmessen
    Check: Befestigungselemente, Befestigungsschrauben und Kupplungsausrichtung überprüfen; Ausrichtung Pumpe-Motor/Antrieb nachmessen

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

IMO Pump Series 4SFC
Series 4SFC ✓ verified
Application
Hydraulic and lubricating oils, general industrial applications
Common Failures & Inspection Points
  • Area: Rotor-to-rotor und Rotor-zu-Gehäuse Spieldimension mit Messuhr überprüfen und gegen OEM-Verschleißgrenzwerte vergleichen (Messung mit Lehren durchführen)
    Check: Rotor-to-rotor und Rotor-zu-Gehäuse Spieldimension mit Messuhr überprüfen und gegen OEM-Verschleißgrenzwerte vergleichen (Messung mit Lehren durchführen)
  • Area: Mechanische Wellendichtung und Gasketdichtheit prüfen: Auf Lecks, Risse, Verfärbungen oder Verhärtung prüfen; Verschleiß von Dichtringflächen inspizieren
    Check: Mechanische Wellendichtung und Gasketdichtheit prüfen: Auf Lecks, Risse, Verfärbungen oder Verhärtung prüfen; Verschleiß von Dichtringflächen inspizieren
  • Area: Gehäusebohrung, Rotoroberflächen und Deckelplatte auf Kratzspuren, Korrosionspitting oder Oberflächenverschleiß kontrollieren (Reinigungsfähigkeit prüfen)
    Check: Gehäusebohrung, Rotoroberflächen und Deckelplatte auf Kratzspuren, Korrosionspitting oder Oberflächenverschleiß kontrollieren (Reinigungsfähigkeit prüfen)
  • Area: Lager und Lagerspiele kontrollieren: Radialspiel und Axialspiel mit geeigneten Messinstrumenten überprüfen; auf Verschleiß und Erhitzung hinweisen
    Check: Lager und Lagerspiele kontrollieren: Radialspiel und Axialspiel mit geeigneten Messinstrumenten überprüfen; auf Verschleiß und Erhitzung hinweisen
  • Area: Druckentlastungsventil und Überdruckschutz funktional testen; Einstellwerte gegen Herstellervorgabe überprüfen
    Check: Druckentlastungsventil und Überdruckschutz funktional testen; Einstellwerte gegen Herstellervorgabe überprüfen
  • Area: Saugsieb und Einlassfilter auf Verschmutzung und Blockierung kontrollieren; Druckabfall über Filter überwachen
    Check: Saugsieb und Einlassfilter auf Verschmutzung und Blockierung kontrollieren; Druckabfall über Filter überwachen
  • Area: Betriebsgeräusche, Vibrationen und ungewöhnliche Sounds diagnostizieren (Hinweis auf innere Verschleißmuster)
    Check: Betriebsgeräusche, Vibrationen und ungewöhnliche Sounds diagnostizieren (Hinweis auf innere Verschleißmuster)
  • Area: Befestigungselemente, Befestigungsschrauben und Kupplungsausrichtung überprüfen; Ausrichtung Pumpe-Motor/Antrieb nachmessen
    Check: Befestigungselemente, Befestigungsschrauben und Kupplungsausrichtung überprüfen; Ausrichtung Pumpe-Motor/Antrieb nachmessen

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

IMO Pump Series 4U/4T
Series 4U/4T ✓ verified
Application
Medium pressure fluid power (cyclic) and gas sealing on compressors
Common Failures & Inspection Points
  • Area: Rotor-to-rotor und Rotor-zu-Gehäuse Spieldimension mit Messuhr überprüfen und gegen OEM-Verschleißgrenzwerte vergleichen (Messung mit Lehren durchführen)
    Check: Rotor-to-rotor und Rotor-zu-Gehäuse Spieldimension mit Messuhr überprüfen und gegen OEM-Verschleißgrenzwerte vergleichen (Messung mit Lehren durchführen)
  • Area: Mechanische Wellendichtung und Gasketdichtheit prüfen: Auf Lecks, Risse, Verfärbungen oder Verhärtung prüfen; Verschleiß von Dichtringflächen inspizieren
    Check: Mechanische Wellendichtung und Gasketdichtheit prüfen: Auf Lecks, Risse, Verfärbungen oder Verhärtung prüfen; Verschleiß von Dichtringflächen inspizieren
  • Area: Gehäusebohrung, Rotoroberflächen und Deckelplatte auf Kratzspuren, Korrosionspitting oder Oberflächenverschleiß kontrollieren (Reinigungsfähigkeit prüfen)
    Check: Gehäusebohrung, Rotoroberflächen und Deckelplatte auf Kratzspuren, Korrosionspitting oder Oberflächenverschleiß kontrollieren (Reinigungsfähigkeit prüfen)
  • Area: Lager und Lagerspiele kontrollieren: Radialspiel und Axialspiel mit geeigneten Messinstrumenten überprüfen; auf Verschleiß und Erhitzung hinweisen
    Check: Lager und Lagerspiele kontrollieren: Radialspiel und Axialspiel mit geeigneten Messinstrumenten überprüfen; auf Verschleiß und Erhitzung hinweisen
  • Area: Druckentlastungsventil und Überdruckschutz funktional testen; Einstellwerte gegen Herstellervorgabe überprüfen
    Check: Druckentlastungsventil und Überdruckschutz funktional testen; Einstellwerte gegen Herstellervorgabe überprüfen
  • Area: Saugsieb und Einlassfilter auf Verschmutzung und Blockierung kontrollieren; Druckabfall über Filter überwachen
    Check: Saugsieb und Einlassfilter auf Verschmutzung und Blockierung kontrollieren; Druckabfall über Filter überwachen
  • Area: Betriebsgeräusche, Vibrationen und ungewöhnliche Sounds diagnostizieren (Hinweis auf innere Verschleißmuster)
    Check: Betriebsgeräusche, Vibrationen und ungewöhnliche Sounds diagnostizieren (Hinweis auf innere Verschleißmuster)
  • Area: Befestigungselemente, Befestigungsschrauben und Kupplungsausrichtung überprüfen; Ausrichtung Pumpe-Motor/Antrieb nachmessen
    Check: Befestigungselemente, Befestigungsschrauben und Kupplungsausrichtung überprüfen; Ausrichtung Pumpe-Motor/Antrieb nachmessen

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

IMO Pump Series 6U/6T
Series 6U/6T ✓ verified
Application
High pressure fluid power (cyclic pressure) and medium pressure gas sealing on compressors
Common Failures & Inspection Points
  • Area: Rotor-to-rotor und Rotor-zu-Gehäuse Spieldimension mit Messuhr überprüfen und gegen OEM-Verschleißgrenzwerte vergleichen (Messung mit Lehren durchführen)
    Check: Rotor-to-rotor und Rotor-zu-Gehäuse Spieldimension mit Messuhr überprüfen und gegen OEM-Verschleißgrenzwerte vergleichen (Messung mit Lehren durchführen)
  • Area: Mechanische Wellendichtung und Gasketdichtheit prüfen: Auf Lecks, Risse, Verfärbungen oder Verhärtung prüfen; Verschleiß von Dichtringflächen inspizieren
    Check: Mechanische Wellendichtung und Gasketdichtheit prüfen: Auf Lecks, Risse, Verfärbungen oder Verhärtung prüfen; Verschleiß von Dichtringflächen inspizieren
  • Area: Gehäusebohrung, Rotoroberflächen und Deckelplatte auf Kratzspuren, Korrosionspitting oder Oberflächenverschleiß kontrollieren (Reinigungsfähigkeit prüfen)
    Check: Gehäusebohrung, Rotoroberflächen und Deckelplatte auf Kratzspuren, Korrosionspitting oder Oberflächenverschleiß kontrollieren (Reinigungsfähigkeit prüfen)
  • Area: Lager und Lagerspiele kontrollieren: Radialspiel und Axialspiel mit geeigneten Messinstrumenten überprüfen; auf Verschleiß und Erhitzung hinweisen
    Check: Lager und Lagerspiele kontrollieren: Radialspiel und Axialspiel mit geeigneten Messinstrumenten überprüfen; auf Verschleiß und Erhitzung hinweisen
  • Area: Druckentlastungsventil und Überdruckschutz funktional testen; Einstellwerte gegen Herstellervorgabe überprüfen
    Check: Druckentlastungsventil und Überdruckschutz funktional testen; Einstellwerte gegen Herstellervorgabe überprüfen
  • Area: Saugsieb und Einlassfilter auf Verschmutzung und Blockierung kontrollieren; Druckabfall über Filter überwachen
    Check: Saugsieb und Einlassfilter auf Verschmutzung und Blockierung kontrollieren; Druckabfall über Filter überwachen
  • Area: Betriebsgeräusche, Vibrationen und ungewöhnliche Sounds diagnostizieren (Hinweis auf innere Verschleißmuster)
    Check: Betriebsgeräusche, Vibrationen und ungewöhnliche Sounds diagnostizieren (Hinweis auf innere Verschleißmuster)
  • Area: Befestigungselemente, Befestigungsschrauben und Kupplungsausrichtung überprüfen; Ausrichtung Pumpe-Motor/Antrieb nachmessen
    Check: Befestigungselemente, Befestigungsschrauben und Kupplungsausrichtung überprüfen; Ausrichtung Pumpe-Motor/Antrieb nachmessen

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

IMO Pump Series USNP/4PIC
Series USNP/4PIC ✓ verified
Application
Direct drive by submersible electric motors, hydraulic elevator applications
Common Failures & Inspection Points
  • Area: Rotor-to-rotor und Rotor-zu-Gehäuse Spieldimension mit Messuhr überprüfen und gegen OEM-Verschleißgrenzwerte vergleichen (Messung mit Lehren durchführen)
    Check: Rotor-to-rotor und Rotor-zu-Gehäuse Spieldimension mit Messuhr überprüfen und gegen OEM-Verschleißgrenzwerte vergleichen (Messung mit Lehren durchführen)
  • Area: Mechanische Wellendichtung und Gasketdichtheit prüfen: Auf Lecks, Risse, Verfärbungen oder Verhärtung prüfen; Verschleiß von Dichtringflächen inspizieren
    Check: Mechanische Wellendichtung und Gasketdichtheit prüfen: Auf Lecks, Risse, Verfärbungen oder Verhärtung prüfen; Verschleiß von Dichtringflächen inspizieren
  • Area: Gehäusebohrung, Rotoroberflächen und Deckelplatte auf Kratzspuren, Korrosionspitting oder Oberflächenverschleiß kontrollieren (Reinigungsfähigkeit prüfen)
    Check: Gehäusebohrung, Rotoroberflächen und Deckelplatte auf Kratzspuren, Korrosionspitting oder Oberflächenverschleiß kontrollieren (Reinigungsfähigkeit prüfen)
  • Area: Lager und Lagerspiele kontrollieren: Radialspiel und Axialspiel mit geeigneten Messinstrumenten überprüfen; auf Verschleiß und Erhitzung hinweisen
    Check: Lager und Lagerspiele kontrollieren: Radialspiel und Axialspiel mit geeigneten Messinstrumenten überprüfen; auf Verschleiß und Erhitzung hinweisen
  • Area: Druckentlastungsventil und Überdruckschutz funktional testen; Einstellwerte gegen Herstellervorgabe überprüfen
    Check: Druckentlastungsventil und Überdruckschutz funktional testen; Einstellwerte gegen Herstellervorgabe überprüfen
  • Area: Saugsieb und Einlassfilter auf Verschmutzung und Blockierung kontrollieren; Druckabfall über Filter überwachen
    Check: Saugsieb und Einlassfilter auf Verschmutzung und Blockierung kontrollieren; Druckabfall über Filter überwachen
  • Area: Betriebsgeräusche, Vibrationen und ungewöhnliche Sounds diagnostizieren (Hinweis auf innere Verschleißmuster)
    Check: Betriebsgeräusche, Vibrationen und ungewöhnliche Sounds diagnostizieren (Hinweis auf innere Verschleißmuster)
  • Area: Befestigungselemente, Befestigungsschrauben und Kupplungsausrichtung überprüfen; Ausrichtung Pumpe-Motor/Antrieb nachmessen
    Check: Befestigungselemente, Befestigungsschrauben und Kupplungsausrichtung überprüfen; Ausrichtung Pumpe-Motor/Antrieb nachmessen

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

IMO Pump Series C324
Series C324 ✓ verified
Application
Machinery lubrication, fuel oil transfer, burner services, asphalt and vacuum tower bottoms processing
Common Failures & Inspection Points
  • Area: Rotor-to-rotor und Rotor-zu-Gehäuse Spieldimension mit Messuhr überprüfen und gegen OEM-Verschleißgrenzwerte vergleichen (Messung mit Lehren durchführen)
    Check: Rotor-to-rotor und Rotor-zu-Gehäuse Spieldimension mit Messuhr überprüfen und gegen OEM-Verschleißgrenzwerte vergleichen (Messung mit Lehren durchführen)
  • Area: Mechanische Wellendichtung und Gasketdichtheit prüfen: Auf Lecks, Risse, Verfärbungen oder Verhärtung prüfen; Verschleiß von Dichtringflächen inspizieren
    Check: Mechanische Wellendichtung und Gasketdichtheit prüfen: Auf Lecks, Risse, Verfärbungen oder Verhärtung prüfen; Verschleiß von Dichtringflächen inspizieren
  • Area: Gehäusebohrung, Rotoroberflächen und Deckelplatte auf Kratzspuren, Korrosionspitting oder Oberflächenverschleiß kontrollieren (Reinigungsfähigkeit prüfen)
    Check: Gehäusebohrung, Rotoroberflächen und Deckelplatte auf Kratzspuren, Korrosionspitting oder Oberflächenverschleiß kontrollieren (Reinigungsfähigkeit prüfen)
  • Area: Lager und Lagerspiele kontrollieren: Radialspiel und Axialspiel mit geeigneten Messinstrumenten überprüfen; auf Verschleiß und Erhitzung hinweisen
    Check: Lager und Lagerspiele kontrollieren: Radialspiel und Axialspiel mit geeigneten Messinstrumenten überprüfen; auf Verschleiß und Erhitzung hinweisen
  • Area: Druckentlastungsventil und Überdruckschutz funktional testen; Einstellwerte gegen Herstellervorgabe überprüfen
    Check: Druckentlastungsventil und Überdruckschutz funktional testen; Einstellwerte gegen Herstellervorgabe überprüfen
  • Area: Saugsieb und Einlassfilter auf Verschmutzung und Blockierung kontrollieren; Druckabfall über Filter überwachen
    Check: Saugsieb und Einlassfilter auf Verschmutzung und Blockierung kontrollieren; Druckabfall über Filter überwachen
  • Area: Betriebsgeräusche, Vibrationen und ungewöhnliche Sounds diagnostizieren (Hinweis auf innere Verschleißmuster)
    Check: Betriebsgeräusche, Vibrationen und ungewöhnliche Sounds diagnostizieren (Hinweis auf innere Verschleißmuster)
  • Area: Befestigungselemente, Befestigungsschrauben und Kupplungsausrichtung überprüfen; Ausrichtung Pumpe-Motor/Antrieb nachmessen
    Check: Befestigungselemente, Befestigungsschrauben und Kupplungsausrichtung überprüfen; Ausrichtung Pumpe-Motor/Antrieb nachmessen

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

IMO Pump Series T324
Series T324 ✓ verified
Application
Crude oil processing and fuel transport
Common Failures & Inspection Points
  • Area: Rotor-to-rotor und Rotor-zu-Gehäuse Spieldimension mit Messuhr überprüfen und gegen OEM-Verschleißgrenzwerte vergleichen (Messung mit Lehren durchführen)
    Check: Rotor-to-rotor und Rotor-zu-Gehäuse Spieldimension mit Messuhr überprüfen und gegen OEM-Verschleißgrenzwerte vergleichen (Messung mit Lehren durchführen)
  • Area: Mechanische Wellendichtung und Gasketdichtheit prüfen: Auf Lecks, Risse, Verfärbungen oder Verhärtung prüfen; Verschleiß von Dichtringflächen inspizieren
    Check: Mechanische Wellendichtung und Gasketdichtheit prüfen: Auf Lecks, Risse, Verfärbungen oder Verhärtung prüfen; Verschleiß von Dichtringflächen inspizieren
  • Area: Gehäusebohrung, Rotoroberflächen und Deckelplatte auf Kratzspuren, Korrosionspitting oder Oberflächenverschleiß kontrollieren (Reinigungsfähigkeit prüfen)
    Check: Gehäusebohrung, Rotoroberflächen und Deckelplatte auf Kratzspuren, Korrosionspitting oder Oberflächenverschleiß kontrollieren (Reinigungsfähigkeit prüfen)
  • Area: Lager und Lagerspiele kontrollieren: Radialspiel und Axialspiel mit geeigneten Messinstrumenten überprüfen; auf Verschleiß und Erhitzung hinweisen
    Check: Lager und Lagerspiele kontrollieren: Radialspiel und Axialspiel mit geeigneten Messinstrumenten überprüfen; auf Verschleiß und Erhitzung hinweisen
  • Area: Druckentlastungsventil und Überdruckschutz funktional testen; Einstellwerte gegen Herstellervorgabe überprüfen
    Check: Druckentlastungsventil und Überdruckschutz funktional testen; Einstellwerte gegen Herstellervorgabe überprüfen
  • Area: Saugsieb und Einlassfilter auf Verschmutzung und Blockierung kontrollieren; Druckabfall über Filter überwachen
    Check: Saugsieb und Einlassfilter auf Verschmutzung und Blockierung kontrollieren; Druckabfall über Filter überwachen
  • Area: Betriebsgeräusche, Vibrationen und ungewöhnliche Sounds diagnostizieren (Hinweis auf innere Verschleißmuster)
    Check: Betriebsgeräusche, Vibrationen und ungewöhnliche Sounds diagnostizieren (Hinweis auf innere Verschleißmuster)
  • Area: Befestigungselemente, Befestigungsschrauben und Kupplungsausrichtung überprüfen; Ausrichtung Pumpe-Motor/Antrieb nachmessen
    Check: Befestigungselemente, Befestigungsschrauben und Kupplungsausrichtung überprüfen; Ausrichtung Pumpe-Motor/Antrieb nachmessen

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

IMO Pump Series 323F
Series 323F ✓ verified
Application
Tank farm services, loading/unloading terminals, power plants, asphalt processing and transfer
Common Failures & Inspection Points
  • Area: Rotor-to-rotor und Rotor-zu-Gehäuse Spieldimension mit Messuhr überprüfen und gegen OEM-Verschleißgrenzwerte vergleichen (Messung mit Lehren durchführen)
    Check: Rotor-to-rotor und Rotor-zu-Gehäuse Spieldimension mit Messuhr überprüfen und gegen OEM-Verschleißgrenzwerte vergleichen (Messung mit Lehren durchführen)
  • Area: Mechanische Wellendichtung und Gasketdichtheit prüfen: Auf Lecks, Risse, Verfärbungen oder Verhärtung prüfen; Verschleiß von Dichtringflächen inspizieren
    Check: Mechanische Wellendichtung und Gasketdichtheit prüfen: Auf Lecks, Risse, Verfärbungen oder Verhärtung prüfen; Verschleiß von Dichtringflächen inspizieren
  • Area: Gehäusebohrung, Rotoroberflächen und Deckelplatte auf Kratzspuren, Korrosionspitting oder Oberflächenverschleiß kontrollieren (Reinigungsfähigkeit prüfen)
    Check: Gehäusebohrung, Rotoroberflächen und Deckelplatte auf Kratzspuren, Korrosionspitting oder Oberflächenverschleiß kontrollieren (Reinigungsfähigkeit prüfen)
  • Area: Lager und Lagerspiele kontrollieren: Radialspiel und Axialspiel mit geeigneten Messinstrumenten überprüfen; auf Verschleiß und Erhitzung hinweisen
    Check: Lager und Lagerspiele kontrollieren: Radialspiel und Axialspiel mit geeigneten Messinstrumenten überprüfen; auf Verschleiß und Erhitzung hinweisen
  • Area: Druckentlastungsventil und Überdruckschutz funktional testen; Einstellwerte gegen Herstellervorgabe überprüfen
    Check: Druckentlastungsventil und Überdruckschutz funktional testen; Einstellwerte gegen Herstellervorgabe überprüfen
  • Area: Saugsieb und Einlassfilter auf Verschmutzung und Blockierung kontrollieren; Druckabfall über Filter überwachen
    Check: Saugsieb und Einlassfilter auf Verschmutzung und Blockierung kontrollieren; Druckabfall über Filter überwachen
  • Area: Betriebsgeräusche, Vibrationen und ungewöhnliche Sounds diagnostizieren (Hinweis auf innere Verschleißmuster)
    Check: Betriebsgeräusche, Vibrationen und ungewöhnliche Sounds diagnostizieren (Hinweis auf innere Verschleißmuster)
  • Area: Befestigungselemente, Befestigungsschrauben und Kupplungsausrichtung überprüfen; Ausrichtung Pumpe-Motor/Antrieb nachmessen
    Check: Befestigungselemente, Befestigungsschrauben und Kupplungsausrichtung überprüfen; Ausrichtung Pumpe-Motor/Antrieb nachmessen

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

IMO Pump Series UCF
Series UCF ✓ verified
Application
Industrial applications, power generation, oil & gas operations, lubrication systems
Common Failures & Inspection Points
  • Area: Rotor-to-rotor und Rotor-zu-Gehäuse Spieldimension mit Messuhr überprüfen und gegen OEM-Verschleißgrenzwerte vergleichen (Messung mit Lehren durchführen)
    Check: Rotor-to-rotor und Rotor-zu-Gehäuse Spieldimension mit Messuhr überprüfen und gegen OEM-Verschleißgrenzwerte vergleichen (Messung mit Lehren durchführen)
  • Area: Mechanische Wellendichtung und Gasketdichtheit prüfen: Auf Lecks, Risse, Verfärbungen oder Verhärtung prüfen; Verschleiß von Dichtringflächen inspizieren
    Check: Mechanische Wellendichtung und Gasketdichtheit prüfen: Auf Lecks, Risse, Verfärbungen oder Verhärtung prüfen; Verschleiß von Dichtringflächen inspizieren
  • Area: Gehäusebohrung, Rotoroberflächen und Deckelplatte auf Kratzspuren, Korrosionspitting oder Oberflächenverschleiß kontrollieren (Reinigungsfähigkeit prüfen)
    Check: Gehäusebohrung, Rotoroberflächen und Deckelplatte auf Kratzspuren, Korrosionspitting oder Oberflächenverschleiß kontrollieren (Reinigungsfähigkeit prüfen)
  • Area: Lager und Lagerspiele kontrollieren: Radialspiel und Axialspiel mit geeigneten Messinstrumenten überprüfen; auf Verschleiß und Erhitzung hinweisen
    Check: Lager und Lagerspiele kontrollieren: Radialspiel und Axialspiel mit geeigneten Messinstrumenten überprüfen; auf Verschleiß und Erhitzung hinweisen
  • Area: Druckentlastungsventil und Überdruckschutz funktional testen; Einstellwerte gegen Herstellervorgabe überprüfen
    Check: Druckentlastungsventil und Überdruckschutz funktional testen; Einstellwerte gegen Herstellervorgabe überprüfen
  • Area: Saugsieb und Einlassfilter auf Verschmutzung und Blockierung kontrollieren; Druckabfall über Filter überwachen
    Check: Saugsieb und Einlassfilter auf Verschmutzung und Blockierung kontrollieren; Druckabfall über Filter überwachen
  • Area: Betriebsgeräusche, Vibrationen und ungewöhnliche Sounds diagnostizieren (Hinweis auf innere Verschleißmuster)
    Check: Betriebsgeräusche, Vibrationen und ungewöhnliche Sounds diagnostizieren (Hinweis auf innere Verschleißmuster)
  • Area: Befestigungselemente, Befestigungsschrauben und Kupplungsausrichtung überprüfen; Ausrichtung Pumpe-Motor/Antrieb nachmessen
    Check: Befestigungselemente, Befestigungsschrauben und Kupplungsausrichtung überprüfen; Ausrichtung Pumpe-Motor/Antrieb nachmessen

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

Roto Pumps

13 ✓ 13 verified
Roto Pumps RD Series (D41, D43, D45, D47, D49, D51, D53, D55)
RD Series (D41, D43, D45, D47, D49, D51, D53, D55) ✓ verified
Application
Small capacity moderate pressure dosing and transfer duties
Common Failures & Inspection Points
  • Area: Rotor-zu-Rotor-Spiel mit Fühlerlehren gegen OEM-Spezifikation messen (kritischer Verschleißindikator)
    Check: Rotor-zu-Rotor-Spiel mit Fühlerlehren gegen OEM-Spezifikation messen (kritischer Verschleißindikator)
  • Area: Wellendichtring- und Gleitringdichtung auf Verschleiß, Lecks und Integrität überprüfen
    Check: Wellendichtring- und Gleitringdichtung auf Verschleiß, Lecks und Integrität überprüfen
  • Area: Flexible Kupplung auf Ausrichtung und Verschleiß prüfen; Drehmoment-Übertragung kontrollieren
    Check: Flexible Kupplung auf Ausrichtung und Verschleiß prüfen; Drehmoment-Übertragung kontrollieren
  • Area: Druckentlastungs-Ventil auf Funktion und Ansprechdruck testen (100% Bypass-Fähigkeit verifizieren)
    Check: Druckentlastungs-Ventil auf Funktion und Ansprechdruck testen (100% Bypass-Fähigkeit verifizieren)
  • Area: Stator-Innenfläche auf Elastomer-Verschleiß, Risse und Ermüdungserscheinungen inspizieren
    Check: Stator-Innenfläche auf Elastomer-Verschleiß, Risse und Ermüdungserscheinungen inspizieren
  • Area: Betriebstemperatur und Systemdruck kontinuierlich überwachen und mit Nennwerten abgleichen
    Check: Betriebstemperatur und Systemdruck kontinuierlich überwachen und mit Nennwerten abgleichen
  • Area: Vibrationsanalyse durchführen zur Früherkennung von Lagerverschleiß oder Unwucht
    Check: Vibrationsanalyse durchführen zur Früherkennung von Lagerverschleiß oder Unwucht
  • Area: Lagerabstände messen und Lagergeräusche auf ungewöhnliche Töne prüfen
    Check: Lagerabstände messen und Lagergeräusche auf ungewöhnliche Töne prüfen

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

Roto Pumps RM Series (M50-M72+) - Standard Geometry
RM Series (M50-M72+) - Standard Geometry ✓ verified
Application
Medium to large capacity continuous transfer and pumping duties
Common Failures & Inspection Points
  • Area: Rotor-zu-Rotor-Spiel mit Fühlerlehren gegen OEM-Spezifikation messen (kritischer Verschleißindikator)
    Check: Rotor-zu-Rotor-Spiel mit Fühlerlehren gegen OEM-Spezifikation messen (kritischer Verschleißindikator)
  • Area: Wellendichtring- und Gleitringdichtung auf Verschleiß, Lecks und Integrität überprüfen
    Check: Wellendichtring- und Gleitringdichtung auf Verschleiß, Lecks und Integrität überprüfen
  • Area: Flexible Kupplung auf Ausrichtung und Verschleiß prüfen; Drehmoment-Übertragung kontrollieren
    Check: Flexible Kupplung auf Ausrichtung und Verschleiß prüfen; Drehmoment-Übertragung kontrollieren
  • Area: Druckentlastungs-Ventil auf Funktion und Ansprechdruck testen (100% Bypass-Fähigkeit verifizieren)
    Check: Druckentlastungs-Ventil auf Funktion und Ansprechdruck testen (100% Bypass-Fähigkeit verifizieren)
  • Area: Stator-Innenfläche auf Elastomer-Verschleiß, Risse und Ermüdungserscheinungen inspizieren
    Check: Stator-Innenfläche auf Elastomer-Verschleiß, Risse und Ermüdungserscheinungen inspizieren
  • Area: Betriebstemperatur und Systemdruck kontinuierlich überwachen und mit Nennwerten abgleichen
    Check: Betriebstemperatur und Systemdruck kontinuierlich überwachen und mit Nennwerten abgleichen
  • Area: Vibrationsanalyse durchführen zur Früherkennung von Lagerverschleiß oder Unwucht
    Check: Vibrationsanalyse durchführen zur Früherkennung von Lagerverschleiß oder Unwucht
  • Area: Lagerabstände messen und Lagergeräusche auf ungewöhnliche Töne prüfen
    Check: Lagerabstände messen und Lagergeräusche auf ungewöhnliche Töne prüfen

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

Roto Pumps RL Series - Extended Geometry
RL Series - Extended Geometry ✓ verified
Application
Extra large capacity general purpose applications
Common Failures & Inspection Points
  • Area: Rotor-zu-Rotor-Spiel mit Fühlerlehren gegen OEM-Spezifikation messen (kritischer Verschleißindikator)
    Check: Rotor-zu-Rotor-Spiel mit Fühlerlehren gegen OEM-Spezifikation messen (kritischer Verschleißindikator)
  • Area: Wellendichtring- und Gleitringdichtung auf Verschleiß, Lecks und Integrität überprüfen
    Check: Wellendichtring- und Gleitringdichtung auf Verschleiß, Lecks und Integrität überprüfen
  • Area: Flexible Kupplung auf Ausrichtung und Verschleiß prüfen; Drehmoment-Übertragung kontrollieren
    Check: Flexible Kupplung auf Ausrichtung und Verschleiß prüfen; Drehmoment-Übertragung kontrollieren
  • Area: Druckentlastungs-Ventil auf Funktion und Ansprechdruck testen (100% Bypass-Fähigkeit verifizieren)
    Check: Druckentlastungs-Ventil auf Funktion und Ansprechdruck testen (100% Bypass-Fähigkeit verifizieren)
  • Area: Stator-Innenfläche auf Elastomer-Verschleiß, Risse und Ermüdungserscheinungen inspizieren
    Check: Stator-Innenfläche auf Elastomer-Verschleiß, Risse und Ermüdungserscheinungen inspizieren
  • Area: Betriebstemperatur und Systemdruck kontinuierlich überwachen und mit Nennwerten abgleichen
    Check: Betriebstemperatur und Systemdruck kontinuierlich überwachen und mit Nennwerten abgleichen
  • Area: Vibrationsanalyse durchführen zur Früherkennung von Lagerverschleiß oder Unwucht
    Check: Vibrationsanalyse durchführen zur Früherkennung von Lagerverschleiß oder Unwucht
  • Area: Lagerabstände messen und Lagergeräusche auf ungewöhnliche Töne prüfen
    Check: Lagerabstände messen und Lagergeräusche auf ungewöhnliche Töne prüfen

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

Roto Pumps RJ Series Dosing Pump
RJ Series Dosing Pump ✓ verified
Application
Chemical dosing and metering across wastewater, chemical, pharmaceutical industries
Common Failures & Inspection Points
  • Area: Rotor-zu-Rotor-Spiel mit Fühlerlehren gegen OEM-Spezifikation messen (kritischer Verschleißindikator)
    Check: Rotor-zu-Rotor-Spiel mit Fühlerlehren gegen OEM-Spezifikation messen (kritischer Verschleißindikator)
  • Area: Wellendichtring- und Gleitringdichtung auf Verschleiß, Lecks und Integrität überprüfen
    Check: Wellendichtring- und Gleitringdichtung auf Verschleiß, Lecks und Integrität überprüfen
  • Area: Flexible Kupplung auf Ausrichtung und Verschleiß prüfen; Drehmoment-Übertragung kontrollieren
    Check: Flexible Kupplung auf Ausrichtung und Verschleiß prüfen; Drehmoment-Übertragung kontrollieren
  • Area: Druckentlastungs-Ventil auf Funktion und Ansprechdruck testen (100% Bypass-Fähigkeit verifizieren)
    Check: Druckentlastungs-Ventil auf Funktion und Ansprechdruck testen (100% Bypass-Fähigkeit verifizieren)
  • Area: Stator-Innenfläche auf Elastomer-Verschleiß, Risse und Ermüdungserscheinungen inspizieren
    Check: Stator-Innenfläche auf Elastomer-Verschleiß, Risse und Ermüdungserscheinungen inspizieren
  • Area: Betriebstemperatur und Systemdruck kontinuierlich überwachen und mit Nennwerten abgleichen
    Check: Betriebstemperatur und Systemdruck kontinuierlich überwachen und mit Nennwerten abgleichen
  • Area: Vibrationsanalyse durchführen zur Früherkennung von Lagerverschleiß oder Unwucht
    Check: Vibrationsanalyse durchführen zur Früherkennung von Lagerverschleiß oder Unwucht
  • Area: Lagerabstände messen und Lagergeräusche auf ungewöhnliche Töne prüfen
    Check: Lagerabstände messen und Lagergeräusche auf ungewöhnliche Töne prüfen

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

Roto Pumps DM Series
DM Series ✓ verified
Application
Food, beverage and cosmetic processing with high viscosity media
Common Failures & Inspection Points
  • Area: Rotor-zu-Rotor-Spiel mit Fühlerlehren gegen OEM-Spezifikation messen (kritischer Verschleißindikator)
    Check: Rotor-zu-Rotor-Spiel mit Fühlerlehren gegen OEM-Spezifikation messen (kritischer Verschleißindikator)
  • Area: Wellendichtring- und Gleitringdichtung auf Verschleiß, Lecks und Integrität überprüfen
    Check: Wellendichtring- und Gleitringdichtung auf Verschleiß, Lecks und Integrität überprüfen
  • Area: Flexible Kupplung auf Ausrichtung und Verschleiß prüfen; Drehmoment-Übertragung kontrollieren
    Check: Flexible Kupplung auf Ausrichtung und Verschleiß prüfen; Drehmoment-Übertragung kontrollieren
  • Area: Druckentlastungs-Ventil auf Funktion und Ansprechdruck testen (100% Bypass-Fähigkeit verifizieren)
    Check: Druckentlastungs-Ventil auf Funktion und Ansprechdruck testen (100% Bypass-Fähigkeit verifizieren)
  • Area: Stator-Innenfläche auf Elastomer-Verschleiß, Risse und Ermüdungserscheinungen inspizieren
    Check: Stator-Innenfläche auf Elastomer-Verschleiß, Risse und Ermüdungserscheinungen inspizieren
  • Area: Betriebstemperatur und Systemdruck kontinuierlich überwachen und mit Nennwerten abgleichen
    Check: Betriebstemperatur und Systemdruck kontinuierlich überwachen und mit Nennwerten abgleichen
  • Area: Vibrationsanalyse durchführen zur Früherkennung von Lagerverschleiß oder Unwucht
    Check: Vibrationsanalyse durchführen zur Früherkennung von Lagerverschleiß oder Unwucht
  • Area: Lagerabstände messen und Lagergeräusche auf ungewöhnliche Töne prüfen
    Check: Lagerabstände messen und Lagergeräusche auf ungewöhnliche Töne prüfen

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

Roto Pumps DC Series
DC Series ✓ verified
Application
Domestic and industrial sewage treatment, general purpose
Common Failures & Inspection Points
  • Area: Rotor-zu-Rotor-Spiel mit Fühlerlehren gegen OEM-Spezifikation messen (kritischer Verschleißindikator)
    Check: Rotor-zu-Rotor-Spiel mit Fühlerlehren gegen OEM-Spezifikation messen (kritischer Verschleißindikator)
  • Area: Wellendichtring- und Gleitringdichtung auf Verschleiß, Lecks und Integrität überprüfen
    Check: Wellendichtring- und Gleitringdichtung auf Verschleiß, Lecks und Integrität überprüfen
  • Area: Flexible Kupplung auf Ausrichtung und Verschleiß prüfen; Drehmoment-Übertragung kontrollieren
    Check: Flexible Kupplung auf Ausrichtung und Verschleiß prüfen; Drehmoment-Übertragung kontrollieren
  • Area: Druckentlastungs-Ventil auf Funktion und Ansprechdruck testen (100% Bypass-Fähigkeit verifizieren)
    Check: Druckentlastungs-Ventil auf Funktion und Ansprechdruck testen (100% Bypass-Fähigkeit verifizieren)
  • Area: Stator-Innenfläche auf Elastomer-Verschleiß, Risse und Ermüdungserscheinungen inspizieren
    Check: Stator-Innenfläche auf Elastomer-Verschleiß, Risse und Ermüdungserscheinungen inspizieren
  • Area: Betriebstemperatur und Systemdruck kontinuierlich überwachen und mit Nennwerten abgleichen
    Check: Betriebstemperatur und Systemdruck kontinuierlich überwachen und mit Nennwerten abgleichen
  • Area: Vibrationsanalyse durchführen zur Früherkennung von Lagerverschleiß oder Unwucht
    Check: Vibrationsanalyse durchführen zur Früherkennung von Lagerverschleiß oder Unwucht
  • Area: Lagerabstände messen und Lagergeräusche auf ungewöhnliche Töne prüfen
    Check: Lagerabstände messen und Lagergeräusche auf ungewöhnliche Töne prüfen

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

Roto Pumps P-Range Progressive Cavity Pump
P-Range Progressive Cavity Pump ✓ verified
Application
Modern applications with superior efficiency and reliability
Common Failures & Inspection Points
  • Area: Rotor-zu-Rotor-Spiel mit Fühlerlehren gegen OEM-Spezifikation messen (kritischer Verschleißindikator)
    Check: Rotor-zu-Rotor-Spiel mit Fühlerlehren gegen OEM-Spezifikation messen (kritischer Verschleißindikator)
  • Area: Wellendichtring- und Gleitringdichtung auf Verschleiß, Lecks und Integrität überprüfen
    Check: Wellendichtring- und Gleitringdichtung auf Verschleiß, Lecks und Integrität überprüfen
  • Area: Flexible Kupplung auf Ausrichtung und Verschleiß prüfen; Drehmoment-Übertragung kontrollieren
    Check: Flexible Kupplung auf Ausrichtung und Verschleiß prüfen; Drehmoment-Übertragung kontrollieren
  • Area: Druckentlastungs-Ventil auf Funktion und Ansprechdruck testen (100% Bypass-Fähigkeit verifizieren)
    Check: Druckentlastungs-Ventil auf Funktion und Ansprechdruck testen (100% Bypass-Fähigkeit verifizieren)
  • Area: Stator-Innenfläche auf Elastomer-Verschleiß, Risse und Ermüdungserscheinungen inspizieren
    Check: Stator-Innenfläche auf Elastomer-Verschleiß, Risse und Ermüdungserscheinungen inspizieren
  • Area: Betriebstemperatur und Systemdruck kontinuierlich überwachen und mit Nennwerten abgleichen
    Check: Betriebstemperatur und Systemdruck kontinuierlich überwachen und mit Nennwerten abgleichen
  • Area: Vibrationsanalyse durchführen zur Früherkennung von Lagerverschleiß oder Unwucht
    Check: Vibrationsanalyse durchführen zur Früherkennung von Lagerverschleiß oder Unwucht
  • Area: Lagerabstände messen und Lagergeräusche auf ungewöhnliche Töne prüfen
    Check: Lagerabstände messen und Lagergeräusche auf ungewöhnliche Töne prüfen

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

Roto Pumps Roto KWIK Pump (MIP)
Roto KWIK Pump (MIP) ✓ verified
Application
Maintenance in Place applications requiring fast service access
Common Failures & Inspection Points
  • Area: Rotor-zu-Rotor-Spiel mit Fühlerlehren gegen OEM-Spezifikation messen (kritischer Verschleißindikator)
    Check: Rotor-zu-Rotor-Spiel mit Fühlerlehren gegen OEM-Spezifikation messen (kritischer Verschleißindikator)
  • Area: Wellendichtring- und Gleitringdichtung auf Verschleiß, Lecks und Integrität überprüfen
    Check: Wellendichtring- und Gleitringdichtung auf Verschleiß, Lecks und Integrität überprüfen
  • Area: Flexible Kupplung auf Ausrichtung und Verschleiß prüfen; Drehmoment-Übertragung kontrollieren
    Check: Flexible Kupplung auf Ausrichtung und Verschleiß prüfen; Drehmoment-Übertragung kontrollieren
  • Area: Druckentlastungs-Ventil auf Funktion und Ansprechdruck testen (100% Bypass-Fähigkeit verifizieren)
    Check: Druckentlastungs-Ventil auf Funktion und Ansprechdruck testen (100% Bypass-Fähigkeit verifizieren)
  • Area: Stator-Innenfläche auf Elastomer-Verschleiß, Risse und Ermüdungserscheinungen inspizieren
    Check: Stator-Innenfläche auf Elastomer-Verschleiß, Risse und Ermüdungserscheinungen inspizieren
  • Area: Betriebstemperatur und Systemdruck kontinuierlich überwachen und mit Nennwerten abgleichen
    Check: Betriebstemperatur und Systemdruck kontinuierlich überwachen und mit Nennwerten abgleichen
  • Area: Vibrationsanalyse durchführen zur Früherkennung von Lagerverschleiß oder Unwucht
    Check: Vibrationsanalyse durchführen zur Früherkennung von Lagerverschleiß oder Unwucht
  • Area: Lagerabstände messen und Lagergeräusche auf ungewöhnliche Töne prüfen
    Check: Lagerabstände messen und Lagergeräusche auf ungewöhnliche Töne prüfen

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

Roto Pumps Roto Cake Pump
Roto Cake Pump ✓ verified
Application
Solids-laden sludge cake with high dry solid contents up to 45%
Common Failures & Inspection Points
  • Area: Rotor-zu-Rotor-Spiel mit Fühlerlehren gegen OEM-Spezifikation messen (kritischer Verschleißindikator)
    Check: Rotor-zu-Rotor-Spiel mit Fühlerlehren gegen OEM-Spezifikation messen (kritischer Verschleißindikator)
  • Area: Wellendichtring- und Gleitringdichtung auf Verschleiß, Lecks und Integrität überprüfen
    Check: Wellendichtring- und Gleitringdichtung auf Verschleiß, Lecks und Integrität überprüfen
  • Area: Flexible Kupplung auf Ausrichtung und Verschleiß prüfen; Drehmoment-Übertragung kontrollieren
    Check: Flexible Kupplung auf Ausrichtung und Verschleiß prüfen; Drehmoment-Übertragung kontrollieren
  • Area: Druckentlastungs-Ventil auf Funktion und Ansprechdruck testen (100% Bypass-Fähigkeit verifizieren)
    Check: Druckentlastungs-Ventil auf Funktion und Ansprechdruck testen (100% Bypass-Fähigkeit verifizieren)
  • Area: Stator-Innenfläche auf Elastomer-Verschleiß, Risse und Ermüdungserscheinungen inspizieren
    Check: Stator-Innenfläche auf Elastomer-Verschleiß, Risse und Ermüdungserscheinungen inspizieren
  • Area: Betriebstemperatur und Systemdruck kontinuierlich überwachen und mit Nennwerten abgleichen
    Check: Betriebstemperatur und Systemdruck kontinuierlich überwachen und mit Nennwerten abgleichen
  • Area: Vibrationsanalyse durchführen zur Früherkennung von Lagerverschleiß oder Unwucht
    Check: Vibrationsanalyse durchführen zur Früherkennung von Lagerverschleiß oder Unwucht
  • Area: Lagerabstände messen und Lagergeräusche auf ungewöhnliche Töne prüfen
    Check: Lagerabstände messen und Lagergeräusche auf ungewöhnliche Töne prüfen

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

Roto Pumps MC Series
MC Series ✓ verified
Application
General pumping and transfer duties
Common Failures & Inspection Points
  • Area: Rotor-zu-Rotor-Spiel mit Fühlerlehren gegen OEM-Spezifikation messen (kritischer Verschleißindikator)
    Check: Rotor-zu-Rotor-Spiel mit Fühlerlehren gegen OEM-Spezifikation messen (kritischer Verschleißindikator)
  • Area: Wellendichtring- und Gleitringdichtung auf Verschleiß, Lecks und Integrität überprüfen
    Check: Wellendichtring- und Gleitringdichtung auf Verschleiß, Lecks und Integrität überprüfen
  • Area: Flexible Kupplung auf Ausrichtung und Verschleiß prüfen; Drehmoment-Übertragung kontrollieren
    Check: Flexible Kupplung auf Ausrichtung und Verschleiß prüfen; Drehmoment-Übertragung kontrollieren
  • Area: Druckentlastungs-Ventil auf Funktion und Ansprechdruck testen (100% Bypass-Fähigkeit verifizieren)
    Check: Druckentlastungs-Ventil auf Funktion und Ansprechdruck testen (100% Bypass-Fähigkeit verifizieren)
  • Area: Stator-Innenfläche auf Elastomer-Verschleiß, Risse und Ermüdungserscheinungen inspizieren
    Check: Stator-Innenfläche auf Elastomer-Verschleiß, Risse und Ermüdungserscheinungen inspizieren
  • Area: Betriebstemperatur und Systemdruck kontinuierlich überwachen und mit Nennwerten abgleichen
    Check: Betriebstemperatur und Systemdruck kontinuierlich überwachen und mit Nennwerten abgleichen
  • Area: Vibrationsanalyse durchführen zur Früherkennung von Lagerverschleiß oder Unwucht
    Check: Vibrationsanalyse durchführen zur Früherkennung von Lagerverschleiß oder Unwucht
  • Area: Lagerabstände messen und Lagergeräusche auf ungewöhnliche Töne prüfen
    Check: Lagerabstände messen und Lagergeräusche auf ungewöhnliche Töne prüfen

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

Roto Pumps RV Series - Vertical Twin Screw
RV Series - Vertical Twin Screw ✓ verified
Application
Space-constrained vertical installations, clean and lubricating fluids
Common Failures & Inspection Points
  • Area: Rotor-zu-Rotor-Spiel mit Fühlerlehren gegen OEM-Spezifikation messen (kritischer Verschleißindikator)
    Check: Rotor-zu-Rotor-Spiel mit Fühlerlehren gegen OEM-Spezifikation messen (kritischer Verschleißindikator)
  • Area: Wellendichtring- und Gleitringdichtung auf Verschleiß, Lecks und Integrität überprüfen
    Check: Wellendichtring- und Gleitringdichtung auf Verschleiß, Lecks und Integrität überprüfen
  • Area: Flexible Kupplung auf Ausrichtung und Verschleiß prüfen; Drehmoment-Übertragung kontrollieren
    Check: Flexible Kupplung auf Ausrichtung und Verschleiß prüfen; Drehmoment-Übertragung kontrollieren
  • Area: Druckentlastungs-Ventil auf Funktion und Ansprechdruck testen (100% Bypass-Fähigkeit verifizieren)
    Check: Druckentlastungs-Ventil auf Funktion und Ansprechdruck testen (100% Bypass-Fähigkeit verifizieren)
  • Area: Stator-Innenfläche auf Elastomer-Verschleiß, Risse und Ermüdungserscheinungen inspizieren
    Check: Stator-Innenfläche auf Elastomer-Verschleiß, Risse und Ermüdungserscheinungen inspizieren
  • Area: Betriebstemperatur und Systemdruck kontinuierlich überwachen und mit Nennwerten abgleichen
    Check: Betriebstemperatur und Systemdruck kontinuierlich überwachen und mit Nennwerten abgleichen
  • Area: Vibrationsanalyse durchführen zur Früherkennung von Lagerverschleiß oder Unwucht
    Check: Vibrationsanalyse durchführen zur Früherkennung von Lagerverschleiß oder Unwucht
  • Area: Lagerabstände messen und Lagergeräusche auf ungewöhnliche Töne prüfen
    Check: Lagerabstände messen und Lagergeräusche auf ungewöhnliche Töne prüfen

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

Roto Pumps RE Series - Horizontal External Bearing Twin Screw
RE Series - Horizontal External Bearing Twin Screw ✓ verified
Application
Handling fluids at varying temperatures and viscosities with corrosive/abrasive characteristics
Common Failures & Inspection Points
  • Area: Rotor-zu-Rotor-Spiel mit Fühlerlehren gegen OEM-Spezifikation messen (kritischer Verschleißindikator)
    Check: Rotor-zu-Rotor-Spiel mit Fühlerlehren gegen OEM-Spezifikation messen (kritischer Verschleißindikator)
  • Area: Wellendichtring- und Gleitringdichtung auf Verschleiß, Lecks und Integrität überprüfen
    Check: Wellendichtring- und Gleitringdichtung auf Verschleiß, Lecks und Integrität überprüfen
  • Area: Flexible Kupplung auf Ausrichtung und Verschleiß prüfen; Drehmoment-Übertragung kontrollieren
    Check: Flexible Kupplung auf Ausrichtung und Verschleiß prüfen; Drehmoment-Übertragung kontrollieren
  • Area: Druckentlastungs-Ventil auf Funktion und Ansprechdruck testen (100% Bypass-Fähigkeit verifizieren)
    Check: Druckentlastungs-Ventil auf Funktion und Ansprechdruck testen (100% Bypass-Fähigkeit verifizieren)
  • Area: Stator-Innenfläche auf Elastomer-Verschleiß, Risse und Ermüdungserscheinungen inspizieren
    Check: Stator-Innenfläche auf Elastomer-Verschleiß, Risse und Ermüdungserscheinungen inspizieren
  • Area: Betriebstemperatur und Systemdruck kontinuierlich überwachen und mit Nennwerten abgleichen
    Check: Betriebstemperatur und Systemdruck kontinuierlich überwachen und mit Nennwerten abgleichen
  • Area: Vibrationsanalyse durchführen zur Früherkennung von Lagerverschleiß oder Unwucht
    Check: Vibrationsanalyse durchführen zur Früherkennung von Lagerverschleiß oder Unwucht
  • Area: Lagerabstände messen und Lagergeräusche auf ungewöhnliche Töne prüfen
    Check: Lagerabstände messen und Lagergeräusche auf ungewöhnliche Töne prüfen

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

Roto Pumps RI Series - Horizontal Internal Bearing Twin Screw
RI Series - Horizontal Internal Bearing Twin Screw ✓ verified
Application
Clean and lubricating media with internal bearing lubrication
Common Failures & Inspection Points
  • Area: Rotor-zu-Rotor-Spiel mit Fühlerlehren gegen OEM-Spezifikation messen (kritischer Verschleißindikator)
    Check: Rotor-zu-Rotor-Spiel mit Fühlerlehren gegen OEM-Spezifikation messen (kritischer Verschleißindikator)
  • Area: Wellendichtring- und Gleitringdichtung auf Verschleiß, Lecks und Integrität überprüfen
    Check: Wellendichtring- und Gleitringdichtung auf Verschleiß, Lecks und Integrität überprüfen
  • Area: Flexible Kupplung auf Ausrichtung und Verschleiß prüfen; Drehmoment-Übertragung kontrollieren
    Check: Flexible Kupplung auf Ausrichtung und Verschleiß prüfen; Drehmoment-Übertragung kontrollieren
  • Area: Druckentlastungs-Ventil auf Funktion und Ansprechdruck testen (100% Bypass-Fähigkeit verifizieren)
    Check: Druckentlastungs-Ventil auf Funktion und Ansprechdruck testen (100% Bypass-Fähigkeit verifizieren)
  • Area: Stator-Innenfläche auf Elastomer-Verschleiß, Risse und Ermüdungserscheinungen inspizieren
    Check: Stator-Innenfläche auf Elastomer-Verschleiß, Risse und Ermüdungserscheinungen inspizieren
  • Area: Betriebstemperatur und Systemdruck kontinuierlich überwachen und mit Nennwerten abgleichen
    Check: Betriebstemperatur und Systemdruck kontinuierlich überwachen und mit Nennwerten abgleichen
  • Area: Vibrationsanalyse durchführen zur Früherkennung von Lagerverschleiß oder Unwucht
    Check: Vibrationsanalyse durchführen zur Früherkennung von Lagerverschleiß oder Unwucht
  • Area: Lagerabstände messen und Lagergeräusche auf ungewöhnliche Töne prüfen
    Check: Lagerabstände messen und Lagergeräusche auf ungewöhnliche Töne prüfen

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

Blackmer

12 ✓ 12 verified
Blackmer S Series Twin Screw Pumps - 2HM/2VM
S Series Twin Screw Pumps - 2HM/2VM ✓ verified
Application
General fluid transfer, temperature control fluids, thermal oil
Common Failures & Inspection Points
  • Area: Pressure gauge monitoring on suction and discharge lines near pump inlet/outlet
    Check: Pressure gauge monitoring on suction and discharge lines near pump inlet/outlet
  • Area: Installation of external pressure relief/bypass valve in discharge line to prevent overpressure
    Check: Installation of external pressure relief/bypass valve in discharge line to prevent overpressure
  • Area: Pump lubrication system condition and oil level verification at regular intervals
    Check: Pump lubrication system condition and oil level verification at regular intervals
  • Area: Seal integrity inspection and monitoring for any leakage during operation
    Check: Seal integrity inspection and monitoring for any leakage during operation
  • Area: Pump operating temperature monitoring (ensure temperature within rated maximum for model)
    Check: Pump operating temperature monitoring (ensure temperature within rated maximum for model)
  • Area: Adequate facility ventilation and purge gas supply (no smoking/fire zones, well-ventilated operating site)
    Check: Adequate facility ventilation and purge gas supply (no smoking/fire zones, well-ventilated operating site)
  • Area: Prevention of dry-running operation (pump must not run dry to avoid sealing damage)
    Check: Prevention of dry-running operation (pump must not run dry to avoid sealing damage)
  • Area: Vibration and noise monitoring to detect internal wear or mechanical issues
    Check: Vibration and noise monitoring to detect internal wear or mechanical issues

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

Blackmer S Series Twin Screw Pumps - 2HR/2VR
S Series Twin Screw Pumps - 2HR/2VR ✓ verified
Application
High-temperature fluid transfer, bitumen, thermal oils
Common Failures & Inspection Points
  • Area: Pressure gauge monitoring on suction and discharge lines near pump inlet/outlet
    Check: Pressure gauge monitoring on suction and discharge lines near pump inlet/outlet
  • Area: Installation of external pressure relief/bypass valve in discharge line to prevent overpressure
    Check: Installation of external pressure relief/bypass valve in discharge line to prevent overpressure
  • Area: Pump lubrication system condition and oil level verification at regular intervals
    Check: Pump lubrication system condition and oil level verification at regular intervals
  • Area: Seal integrity inspection and monitoring for any leakage during operation
    Check: Seal integrity inspection and monitoring for any leakage during operation
  • Area: Pump operating temperature monitoring (ensure temperature within rated maximum for model)
    Check: Pump operating temperature monitoring (ensure temperature within rated maximum for model)
  • Area: Adequate facility ventilation and purge gas supply (no smoking/fire zones, well-ventilated operating site)
    Check: Adequate facility ventilation and purge gas supply (no smoking/fire zones, well-ventilated operating site)
  • Area: Prevention of dry-running operation (pump must not run dry to avoid sealing damage)
    Check: Prevention of dry-running operation (pump must not run dry to avoid sealing damage)
  • Area: Vibration and noise monitoring to detect internal wear or mechanical issues
    Check: Vibration and noise monitoring to detect internal wear or mechanical issues

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

Blackmer S Series Twin Screw Pumps - 2HE/2VE
S Series Twin Screw Pumps - 2HE/2VE ✓ verified
Application
Emulsion transfer, juice processing, low-pressure applications
Common Failures & Inspection Points
  • Area: Pressure gauge monitoring on suction and discharge lines near pump inlet/outlet
    Check: Pressure gauge monitoring on suction and discharge lines near pump inlet/outlet
  • Area: Installation of external pressure relief/bypass valve in discharge line to prevent overpressure
    Check: Installation of external pressure relief/bypass valve in discharge line to prevent overpressure
  • Area: Pump lubrication system condition and oil level verification at regular intervals
    Check: Pump lubrication system condition and oil level verification at regular intervals
  • Area: Seal integrity inspection and monitoring for any leakage during operation
    Check: Seal integrity inspection and monitoring for any leakage during operation
  • Area: Pump operating temperature monitoring (ensure temperature within rated maximum for model)
    Check: Pump operating temperature monitoring (ensure temperature within rated maximum for model)
  • Area: Adequate facility ventilation and purge gas supply (no smoking/fire zones, well-ventilated operating site)
    Check: Adequate facility ventilation and purge gas supply (no smoking/fire zones, well-ventilated operating site)
  • Area: Prevention of dry-running operation (pump must not run dry to avoid sealing damage)
    Check: Prevention of dry-running operation (pump must not run dry to avoid sealing damage)
  • Area: Vibration and noise monitoring to detect internal wear or mechanical issues
    Check: Vibration and noise monitoring to detect internal wear or mechanical issues

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

Blackmer S Series Twin Screw Pumps - 2HH
S Series Twin Screw Pumps - 2HH ✓ verified
Application
High-pressure, high-viscosity fluid transfer, industrial oils
Common Failures & Inspection Points
  • Area: Pressure gauge monitoring on suction and discharge lines near pump inlet/outlet
    Check: Pressure gauge monitoring on suction and discharge lines near pump inlet/outlet
  • Area: Installation of external pressure relief/bypass valve in discharge line to prevent overpressure
    Check: Installation of external pressure relief/bypass valve in discharge line to prevent overpressure
  • Area: Pump lubrication system condition and oil level verification at regular intervals
    Check: Pump lubrication system condition and oil level verification at regular intervals
  • Area: Seal integrity inspection and monitoring for any leakage during operation
    Check: Seal integrity inspection and monitoring for any leakage during operation
  • Area: Pump operating temperature monitoring (ensure temperature within rated maximum for model)
    Check: Pump operating temperature monitoring (ensure temperature within rated maximum for model)
  • Area: Adequate facility ventilation and purge gas supply (no smoking/fire zones, well-ventilated operating site)
    Check: Adequate facility ventilation and purge gas supply (no smoking/fire zones, well-ventilated operating site)
  • Area: Prevention of dry-running operation (pump must not run dry to avoid sealing damage)
    Check: Prevention of dry-running operation (pump must not run dry to avoid sealing damage)
  • Area: Vibration and noise monitoring to detect internal wear or mechanical issues
    Check: Vibration and noise monitoring to detect internal wear or mechanical issues

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

Blackmer S Series Twin Screw Pumps - 2HC
S Series Twin Screw Pumps - 2HC ✓ verified
Application
High-capacity, low-pressure transfer, fuels, oils
Common Failures & Inspection Points
  • Area: Pressure gauge monitoring on suction and discharge lines near pump inlet/outlet
    Check: Pressure gauge monitoring on suction and discharge lines near pump inlet/outlet
  • Area: Installation of external pressure relief/bypass valve in discharge line to prevent overpressure
    Check: Installation of external pressure relief/bypass valve in discharge line to prevent overpressure
  • Area: Pump lubrication system condition and oil level verification at regular intervals
    Check: Pump lubrication system condition and oil level verification at regular intervals
  • Area: Seal integrity inspection and monitoring for any leakage during operation
    Check: Seal integrity inspection and monitoring for any leakage during operation
  • Area: Pump operating temperature monitoring (ensure temperature within rated maximum for model)
    Check: Pump operating temperature monitoring (ensure temperature within rated maximum for model)
  • Area: Adequate facility ventilation and purge gas supply (no smoking/fire zones, well-ventilated operating site)
    Check: Adequate facility ventilation and purge gas supply (no smoking/fire zones, well-ventilated operating site)
  • Area: Prevention of dry-running operation (pump must not run dry to avoid sealing damage)
    Check: Prevention of dry-running operation (pump must not run dry to avoid sealing damage)
  • Area: Vibration and noise monitoring to detect internal wear or mechanical issues
    Check: Vibration and noise monitoring to detect internal wear or mechanical issues

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

Blackmer S Series Twin Screw Pumps - 2H
S Series Twin Screw Pumps - 2H ✓ verified
Application
General duty, versatile fluid transfer, moderate viscosity fluids
Common Failures & Inspection Points
  • Area: Pressure gauge monitoring on suction and discharge lines near pump inlet/outlet
    Check: Pressure gauge monitoring on suction and discharge lines near pump inlet/outlet
  • Area: Installation of external pressure relief/bypass valve in discharge line to prevent overpressure
    Check: Installation of external pressure relief/bypass valve in discharge line to prevent overpressure
  • Area: Pump lubrication system condition and oil level verification at regular intervals
    Check: Pump lubrication system condition and oil level verification at regular intervals
  • Area: Seal integrity inspection and monitoring for any leakage during operation
    Check: Seal integrity inspection and monitoring for any leakage during operation
  • Area: Pump operating temperature monitoring (ensure temperature within rated maximum for model)
    Check: Pump operating temperature monitoring (ensure temperature within rated maximum for model)
  • Area: Adequate facility ventilation and purge gas supply (no smoking/fire zones, well-ventilated operating site)
    Check: Adequate facility ventilation and purge gas supply (no smoking/fire zones, well-ventilated operating site)
  • Area: Prevention of dry-running operation (pump must not run dry to avoid sealing damage)
    Check: Prevention of dry-running operation (pump must not run dry to avoid sealing damage)
  • Area: Vibration and noise monitoring to detect internal wear or mechanical issues
    Check: Vibration and noise monitoring to detect internal wear or mechanical issues

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

Blackmer S Series Multi-Phase Twin Screw Pumps - 2MPS...B
S Series Multi-Phase Twin Screw Pumps - 2MPS...B ✓ verified
Application
Water-oil separation, low-pressure multi-phase applications, gas handling up to 80%
Common Failures & Inspection Points
  • Area: Pressure gauge monitoring on suction and discharge lines near pump inlet/outlet
    Check: Pressure gauge monitoring on suction and discharge lines near pump inlet/outlet
  • Area: Installation of external pressure relief/bypass valve in discharge line to prevent overpressure
    Check: Installation of external pressure relief/bypass valve in discharge line to prevent overpressure
  • Area: Pump lubrication system condition and oil level verification at regular intervals
    Check: Pump lubrication system condition and oil level verification at regular intervals
  • Area: Seal integrity inspection and monitoring for any leakage during operation
    Check: Seal integrity inspection and monitoring for any leakage during operation
  • Area: Pump operating temperature monitoring (ensure temperature within rated maximum for model)
    Check: Pump operating temperature monitoring (ensure temperature within rated maximum for model)
  • Area: Adequate facility ventilation and purge gas supply (no smoking/fire zones, well-ventilated operating site)
    Check: Adequate facility ventilation and purge gas supply (no smoking/fire zones, well-ventilated operating site)
  • Area: Prevention of dry-running operation (pump must not run dry to avoid sealing damage)
    Check: Prevention of dry-running operation (pump must not run dry to avoid sealing damage)
  • Area: Vibration and noise monitoring to detect internal wear or mechanical issues
    Check: Vibration and noise monitoring to detect internal wear or mechanical issues

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

Blackmer S Series Multi-Phase Twin Screw Pumps - 2MPS...H
S Series Multi-Phase Twin Screw Pumps - 2MPS...H ✓ verified
Application
Multi-phase fluid transfer, gas handling up to 97%, oilfield operations
Common Failures & Inspection Points
  • Area: Pressure gauge monitoring on suction and discharge lines near pump inlet/outlet
    Check: Pressure gauge monitoring on suction and discharge lines near pump inlet/outlet
  • Area: Installation of external pressure relief/bypass valve in discharge line to prevent overpressure
    Check: Installation of external pressure relief/bypass valve in discharge line to prevent overpressure
  • Area: Pump lubrication system condition and oil level verification at regular intervals
    Check: Pump lubrication system condition and oil level verification at regular intervals
  • Area: Seal integrity inspection and monitoring for any leakage during operation
    Check: Seal integrity inspection and monitoring for any leakage during operation
  • Area: Pump operating temperature monitoring (ensure temperature within rated maximum for model)
    Check: Pump operating temperature monitoring (ensure temperature within rated maximum for model)
  • Area: Adequate facility ventilation and purge gas supply (no smoking/fire zones, well-ventilated operating site)
    Check: Adequate facility ventilation and purge gas supply (no smoking/fire zones, well-ventilated operating site)
  • Area: Prevention of dry-running operation (pump must not run dry to avoid sealing damage)
    Check: Prevention of dry-running operation (pump must not run dry to avoid sealing damage)
  • Area: Vibration and noise monitoring to detect internal wear or mechanical issues
    Check: Vibration and noise monitoring to detect internal wear or mechanical issues

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

Blackmer S Series Multi-Phase Twin Screw Pumps - 2MP
S Series Multi-Phase Twin Screw Pumps - 2MP ✓ verified
Application
High-pressure multi-phase fluid transfer, gas handling up to 97%
Common Failures & Inspection Points
  • Area: Pressure gauge monitoring on suction and discharge lines near pump inlet/outlet
    Check: Pressure gauge monitoring on suction and discharge lines near pump inlet/outlet
  • Area: Installation of external pressure relief/bypass valve in discharge line to prevent overpressure
    Check: Installation of external pressure relief/bypass valve in discharge line to prevent overpressure
  • Area: Pump lubrication system condition and oil level verification at regular intervals
    Check: Pump lubrication system condition and oil level verification at regular intervals
  • Area: Seal integrity inspection and monitoring for any leakage during operation
    Check: Seal integrity inspection and monitoring for any leakage during operation
  • Area: Pump operating temperature monitoring (ensure temperature within rated maximum for model)
    Check: Pump operating temperature monitoring (ensure temperature within rated maximum for model)
  • Area: Adequate facility ventilation and purge gas supply (no smoking/fire zones, well-ventilated operating site)
    Check: Adequate facility ventilation and purge gas supply (no smoking/fire zones, well-ventilated operating site)
  • Area: Prevention of dry-running operation (pump must not run dry to avoid sealing damage)
    Check: Prevention of dry-running operation (pump must not run dry to avoid sealing damage)
  • Area: Vibration and noise monitoring to detect internal wear or mechanical issues
    Check: Vibration and noise monitoring to detect internal wear or mechanical issues

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

Blackmer S Series Triple Screw Pumps - 3N
S Series Triple Screw Pumps - 3N ✓ verified
Application
Lubricating oils, hydraulic oils, fuel oils, diesel transfer
Common Failures & Inspection Points
  • Area: Pressure gauge monitoring on suction and discharge lines near pump inlet/outlet
    Check: Pressure gauge monitoring on suction and discharge lines near pump inlet/outlet
  • Area: Installation of external pressure relief/bypass valve in discharge line to prevent overpressure
    Check: Installation of external pressure relief/bypass valve in discharge line to prevent overpressure
  • Area: Pump lubrication system condition and oil level verification at regular intervals
    Check: Pump lubrication system condition and oil level verification at regular intervals
  • Area: Seal integrity inspection and monitoring for any leakage during operation
    Check: Seal integrity inspection and monitoring for any leakage during operation
  • Area: Pump operating temperature monitoring (ensure temperature within rated maximum for model)
    Check: Pump operating temperature monitoring (ensure temperature within rated maximum for model)
  • Area: Adequate facility ventilation and purge gas supply (no smoking/fire zones, well-ventilated operating site)
    Check: Adequate facility ventilation and purge gas supply (no smoking/fire zones, well-ventilated operating site)
  • Area: Prevention of dry-running operation (pump must not run dry to avoid sealing damage)
    Check: Prevention of dry-running operation (pump must not run dry to avoid sealing damage)
  • Area: Vibration and noise monitoring to detect internal wear or mechanical issues
    Check: Vibration and noise monitoring to detect internal wear or mechanical issues

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

Blackmer S Series Triple Screw Pumps - 3M
S Series Triple Screw Pumps - 3M ✓ verified
Application
High-pressure fuel and hydraulic oil transfer, marine and industrial applications
Common Failures & Inspection Points
  • Area: Pressure gauge monitoring on suction and discharge lines near pump inlet/outlet
    Check: Pressure gauge monitoring on suction and discharge lines near pump inlet/outlet
  • Area: Installation of external pressure relief/bypass valve in discharge line to prevent overpressure
    Check: Installation of external pressure relief/bypass valve in discharge line to prevent overpressure
  • Area: Pump lubrication system condition and oil level verification at regular intervals
    Check: Pump lubrication system condition and oil level verification at regular intervals
  • Area: Seal integrity inspection and monitoring for any leakage during operation
    Check: Seal integrity inspection and monitoring for any leakage during operation
  • Area: Pump operating temperature monitoring (ensure temperature within rated maximum for model)
    Check: Pump operating temperature monitoring (ensure temperature within rated maximum for model)
  • Area: Adequate facility ventilation and purge gas supply (no smoking/fire zones, well-ventilated operating site)
    Check: Adequate facility ventilation and purge gas supply (no smoking/fire zones, well-ventilated operating site)
  • Area: Prevention of dry-running operation (pump must not run dry to avoid sealing damage)
    Check: Prevention of dry-running operation (pump must not run dry to avoid sealing damage)
  • Area: Vibration and noise monitoring to detect internal wear or mechanical issues
    Check: Vibration and noise monitoring to detect internal wear or mechanical issues

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

Blackmer S Series Triple Screw Pumps - 3PF
S Series Triple Screw Pumps - 3PF ✓ verified
Application
Fuel systems, furnace heating systems, hydraulic transmission, low-flow applications
Common Failures & Inspection Points
  • Area: Pressure gauge monitoring on suction and discharge lines near pump inlet/outlet
    Check: Pressure gauge monitoring on suction and discharge lines near pump inlet/outlet
  • Area: Installation of external pressure relief/bypass valve in discharge line to prevent overpressure
    Check: Installation of external pressure relief/bypass valve in discharge line to prevent overpressure
  • Area: Pump lubrication system condition and oil level verification at regular intervals
    Check: Pump lubrication system condition and oil level verification at regular intervals
  • Area: Seal integrity inspection and monitoring for any leakage during operation
    Check: Seal integrity inspection and monitoring for any leakage during operation
  • Area: Pump operating temperature monitoring (ensure temperature within rated maximum for model)
    Check: Pump operating temperature monitoring (ensure temperature within rated maximum for model)
  • Area: Adequate facility ventilation and purge gas supply (no smoking/fire zones, well-ventilated operating site)
    Check: Adequate facility ventilation and purge gas supply (no smoking/fire zones, well-ventilated operating site)
  • Area: Prevention of dry-running operation (pump must not run dry to avoid sealing damage)
    Check: Prevention of dry-running operation (pump must not run dry to avoid sealing damage)
  • Area: Vibration and noise monitoring to detect internal wear or mechanical issues
    Check: Vibration and noise monitoring to detect internal wear or mechanical issues

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

Pumpenfabrik Wangen

7 ✓ 7 verified
Pumpenfabrik Wangen WANGEN Twin NG 70
WANGEN Twin NG 70 ✓ verified
Application
Hygienic twin screw pump for low to highly viscous, volatile or gaseous products in food & beverage, chemical, and cosmetics industries
Common Failures & Inspection Points
  • Area: Spindle shaft synchronization and alignment (for Twin NG models with fast-X-change technology)
    Check: Spindle shaft synchronization and alignment (for Twin NG models with fast-X-change technology)
  • Area: Mechanical seal condition and cartridge design integrity
    Check: Mechanical seal condition and cartridge design integrity
  • Area: Rotor and stator wear patterns and clearances
    Check: Rotor and stator wear patterns and clearances
  • Area: Suction and discharge port connections and dead space deposits
    Check: Suction and discharge port connections and dead space deposits
  • Area: Bearing bracket self-centering mechanism and coupling alignment
    Check: Bearing bracket self-centering mechanism and coupling alignment
  • Area: Coreless screw conveyor integrity (for VarioTwin models)
    Check: Coreless screw conveyor integrity (for VarioTwin models)
  • Area: Hopper and feed mechanism sealing and residue buildup
    Check: Hopper and feed mechanism sealing and residue buildup
  • Area: Temperature and pressure gauge readings during operation
    Check: Temperature and pressure gauge readings during operation

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

Pumpenfabrik Wangen WANGEN Twin NG 104
WANGEN Twin NG 104 ✓ verified
Application
Hygienic twin screw pump for low to highly viscous, volatile or gaseous products in food & beverage, chemical, and cosmetics industries
Common Failures & Inspection Points
  • Area: Spindle shaft synchronization and alignment (for Twin NG models with fast-X-change technology)
    Check: Spindle shaft synchronization and alignment (for Twin NG models with fast-X-change technology)
  • Area: Mechanical seal condition and cartridge design integrity
    Check: Mechanical seal condition and cartridge design integrity
  • Area: Rotor and stator wear patterns and clearances
    Check: Rotor and stator wear patterns and clearances
  • Area: Suction and discharge port connections and dead space deposits
    Check: Suction and discharge port connections and dead space deposits
  • Area: Bearing bracket self-centering mechanism and coupling alignment
    Check: Bearing bracket self-centering mechanism and coupling alignment
  • Area: Coreless screw conveyor integrity (for VarioTwin models)
    Check: Coreless screw conveyor integrity (for VarioTwin models)
  • Area: Hopper and feed mechanism sealing and residue buildup
    Check: Hopper and feed mechanism sealing and residue buildup
  • Area: Temperature and pressure gauge readings during operation
    Check: Temperature and pressure gauge readings during operation

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

Pumpenfabrik Wangen WANGEN Twin NG 130
WANGEN Twin NG 130 ✓ verified
Application
Hygienic twin screw pump for low to highly viscous, volatile or gaseous products in food & beverage, chemical, and cosmetics industries
Common Failures & Inspection Points
  • Area: Spindle shaft synchronization and alignment (for Twin NG models with fast-X-change technology)
    Check: Spindle shaft synchronization and alignment (for Twin NG models with fast-X-change technology)
  • Area: Mechanical seal condition and cartridge design integrity
    Check: Mechanical seal condition and cartridge design integrity
  • Area: Rotor and stator wear patterns and clearances
    Check: Rotor and stator wear patterns and clearances
  • Area: Suction and discharge port connections and dead space deposits
    Check: Suction and discharge port connections and dead space deposits
  • Area: Bearing bracket self-centering mechanism and coupling alignment
    Check: Bearing bracket self-centering mechanism and coupling alignment
  • Area: Coreless screw conveyor integrity (for VarioTwin models)
    Check: Coreless screw conveyor integrity (for VarioTwin models)
  • Area: Hopper and feed mechanism sealing and residue buildup
    Check: Hopper and feed mechanism sealing and residue buildup
  • Area: Temperature and pressure gauge readings during operation
    Check: Temperature and pressure gauge readings during operation

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

Pumpenfabrik Wangen WANGEN Twin NG 180
WANGEN Twin NG 180 ✓ verified
Application
Hygienic twin screw pump for low to highly viscous, volatile or gaseous products in food & beverage, chemical, and cosmetics industries
Common Failures & Inspection Points
  • Area: Spindle shaft synchronization and alignment (for Twin NG models with fast-X-change technology)
    Check: Spindle shaft synchronization and alignment (for Twin NG models with fast-X-change technology)
  • Area: Mechanical seal condition and cartridge design integrity
    Check: Mechanical seal condition and cartridge design integrity
  • Area: Rotor and stator wear patterns and clearances
    Check: Rotor and stator wear patterns and clearances
  • Area: Suction and discharge port connections and dead space deposits
    Check: Suction and discharge port connections and dead space deposits
  • Area: Bearing bracket self-centering mechanism and coupling alignment
    Check: Bearing bracket self-centering mechanism and coupling alignment
  • Area: Coreless screw conveyor integrity (for VarioTwin models)
    Check: Coreless screw conveyor integrity (for VarioTwin models)
  • Area: Hopper and feed mechanism sealing and residue buildup
    Check: Hopper and feed mechanism sealing and residue buildup
  • Area: Temperature and pressure gauge readings during operation
    Check: Temperature and pressure gauge readings during operation

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

Pumpenfabrik Wangen WANGEN VarioTwin NG 104
WANGEN VarioTwin NG 104 ✓ verified
Application
Hygienic twin screw pump feeder unit for forced feeding of high-viscosity, non-flowable media in food, bakery, dairy, meat processing, cosmetics, and chemical applications
Common Failures & Inspection Points
  • Area: Spindle shaft synchronization and alignment (for Twin NG models with fast-X-change technology)
    Check: Spindle shaft synchronization and alignment (for Twin NG models with fast-X-change technology)
  • Area: Mechanical seal condition and cartridge design integrity
    Check: Mechanical seal condition and cartridge design integrity
  • Area: Rotor and stator wear patterns and clearances
    Check: Rotor and stator wear patterns and clearances
  • Area: Suction and discharge port connections and dead space deposits
    Check: Suction and discharge port connections and dead space deposits
  • Area: Bearing bracket self-centering mechanism and coupling alignment
    Check: Bearing bracket self-centering mechanism and coupling alignment
  • Area: Coreless screw conveyor integrity (for VarioTwin models)
    Check: Coreless screw conveyor integrity (for VarioTwin models)
  • Area: Hopper and feed mechanism sealing and residue buildup
    Check: Hopper and feed mechanism sealing and residue buildup
  • Area: Temperature and pressure gauge readings during operation
    Check: Temperature and pressure gauge readings during operation

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

Pumpenfabrik Wangen WANGEN VarioTwin NG 130
WANGEN VarioTwin NG 130 ✓ verified
Application
Hygienic twin screw pump feeder unit for forced feeding of high-viscosity, non-flowable media in food, bakery, dairy, meat processing, cosmetics, and chemical applications
Common Failures & Inspection Points
  • Area: Spindle shaft synchronization and alignment (for Twin NG models with fast-X-change technology)
    Check: Spindle shaft synchronization and alignment (for Twin NG models with fast-X-change technology)
  • Area: Mechanical seal condition and cartridge design integrity
    Check: Mechanical seal condition and cartridge design integrity
  • Area: Rotor and stator wear patterns and clearances
    Check: Rotor and stator wear patterns and clearances
  • Area: Suction and discharge port connections and dead space deposits
    Check: Suction and discharge port connections and dead space deposits
  • Area: Bearing bracket self-centering mechanism and coupling alignment
    Check: Bearing bracket self-centering mechanism and coupling alignment
  • Area: Coreless screw conveyor integrity (for VarioTwin models)
    Check: Coreless screw conveyor integrity (for VarioTwin models)
  • Area: Hopper and feed mechanism sealing and residue buildup
    Check: Hopper and feed mechanism sealing and residue buildup
  • Area: Temperature and pressure gauge readings during operation
    Check: Temperature and pressure gauge readings during operation

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

Pumpenfabrik Wangen WANGEN KL-S
WANGEN KL-S ✓ verified
Application
Self-priming progressing cavity pump for universal applications across agriculture, biogas, food processing, waste treatment, chemical handling
Common Failures & Inspection Points
  • Area: Spindle shaft synchronization and alignment (for Twin NG models with fast-X-change technology)
    Check: Spindle shaft synchronization and alignment (for Twin NG models with fast-X-change technology)
  • Area: Mechanical seal condition and cartridge design integrity
    Check: Mechanical seal condition and cartridge design integrity
  • Area: Rotor and stator wear patterns and clearances
    Check: Rotor and stator wear patterns and clearances
  • Area: Suction and discharge port connections and dead space deposits
    Check: Suction and discharge port connections and dead space deposits
  • Area: Bearing bracket self-centering mechanism and coupling alignment
    Check: Bearing bracket self-centering mechanism and coupling alignment
  • Area: Coreless screw conveyor integrity (for VarioTwin models)
    Check: Coreless screw conveyor integrity (for VarioTwin models)
  • Area: Hopper and feed mechanism sealing and residue buildup
    Check: Hopper and feed mechanism sealing and residue buildup
  • Area: Temperature and pressure gauge readings during operation
    Check: Temperature and pressure gauge readings during operation

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

SPX FLOW / Celeros Flow Technology

7 ✓ 7 verified
SPX FLOW / Celeros Flow Technology TRIRO Three Screw Pump - T-Range
TRIRO Three Screw Pump - T-Range ✓ verified
Application
Low cost general industrial pump for clean liquids; bulk transfer applications
Common Failures & Inspection Points
  • Area: Rotor-to-rotor clearance measurement and wear tolerance verification against OEM specifications
    Check: Rotor-to-rotor clearance measurement and wear tolerance verification against OEM specifications
  • Area: Rotor-to-casing clearance inspection using feeler gauges to detect excessive wear and internal slip
    Check: Rotor-to-casing clearance inspection using feeler gauges to detect excessive wear and internal slip
  • Area: Timing gear condition assessment and backlash measurement
    Check: Timing gear condition assessment and backlash measurement
  • Area: Mechanical seal integrity and material compatibility inspection for contamination pathways
    Check: Mechanical seal integrity and material compatibility inspection for contamination pathways
  • Area: Gasket and seal condition check for deterioration, leakage, and sanitary separation effectiveness
    Check: Gasket and seal condition check for deterioration, leakage, and sanitary separation effectiveness
  • Area: Bearing lubrication level and oil condition (viscosity, contamination, moisture content)
    Check: Bearing lubrication level and oil condition (viscosity, contamination, moisture content)
  • Area: Coupling alignment, wear, and guard integrity verification
    Check: Coupling alignment, wear, and guard integrity verification
  • Area: Suction and discharge line pressure and temperature monitoring for abnormal operation
    Check: Suction and discharge line pressure and temperature monitoring for abnormal operation

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

SPX FLOW / Celeros Flow Technology TRIRO Three Screw Pump - C-Range
TRIRO Three Screw Pump - C-Range ✓ verified
Application
Medium pressure high flow applications on clean liquids; offshore oil and gas forced lubrication systems
Common Failures & Inspection Points
  • Area: Rotor-to-rotor clearance measurement and wear tolerance verification against OEM specifications
    Check: Rotor-to-rotor clearance measurement and wear tolerance verification against OEM specifications
  • Area: Rotor-to-casing clearance inspection using feeler gauges to detect excessive wear and internal slip
    Check: Rotor-to-casing clearance inspection using feeler gauges to detect excessive wear and internal slip
  • Area: Timing gear condition assessment and backlash measurement
    Check: Timing gear condition assessment and backlash measurement
  • Area: Mechanical seal integrity and material compatibility inspection for contamination pathways
    Check: Mechanical seal integrity and material compatibility inspection for contamination pathways
  • Area: Gasket and seal condition check for deterioration, leakage, and sanitary separation effectiveness
    Check: Gasket and seal condition check for deterioration, leakage, and sanitary separation effectiveness
  • Area: Bearing lubrication level and oil condition (viscosity, contamination, moisture content)
    Check: Bearing lubrication level and oil condition (viscosity, contamination, moisture content)
  • Area: Coupling alignment, wear, and guard integrity verification
    Check: Coupling alignment, wear, and guard integrity verification
  • Area: Suction and discharge line pressure and temperature monitoring for abnormal operation
    Check: Suction and discharge line pressure and temperature monitoring for abnormal operation

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

SPX FLOW / Celeros Flow Technology TRIRO Three Screw Pump - E-Range
TRIRO Three Screw Pump - E-Range ✓ verified
Application
Medium pressure high flow applications on clean liquids
Common Failures & Inspection Points
  • Area: Rotor-to-rotor clearance measurement and wear tolerance verification against OEM specifications
    Check: Rotor-to-rotor clearance measurement and wear tolerance verification against OEM specifications
  • Area: Rotor-to-casing clearance inspection using feeler gauges to detect excessive wear and internal slip
    Check: Rotor-to-casing clearance inspection using feeler gauges to detect excessive wear and internal slip
  • Area: Timing gear condition assessment and backlash measurement
    Check: Timing gear condition assessment and backlash measurement
  • Area: Mechanical seal integrity and material compatibility inspection for contamination pathways
    Check: Mechanical seal integrity and material compatibility inspection for contamination pathways
  • Area: Gasket and seal condition check for deterioration, leakage, and sanitary separation effectiveness
    Check: Gasket and seal condition check for deterioration, leakage, and sanitary separation effectiveness
  • Area: Bearing lubrication level and oil condition (viscosity, contamination, moisture content)
    Check: Bearing lubrication level and oil condition (viscosity, contamination, moisture content)
  • Area: Coupling alignment, wear, and guard integrity verification
    Check: Coupling alignment, wear, and guard integrity verification
  • Area: Suction and discharge line pressure and temperature monitoring for abnormal operation
    Check: Suction and discharge line pressure and temperature monitoring for abnormal operation

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

SPX FLOW / Celeros Flow Technology TRIRO Three Screw Pump - H-Range
TRIRO Three Screw Pump - H-Range ✓ verified
Application
High pressure applications on clean liquids
Common Failures & Inspection Points
  • Area: Rotor-to-rotor clearance measurement and wear tolerance verification against OEM specifications
    Check: Rotor-to-rotor clearance measurement and wear tolerance verification against OEM specifications
  • Area: Rotor-to-casing clearance inspection using feeler gauges to detect excessive wear and internal slip
    Check: Rotor-to-casing clearance inspection using feeler gauges to detect excessive wear and internal slip
  • Area: Timing gear condition assessment and backlash measurement
    Check: Timing gear condition assessment and backlash measurement
  • Area: Mechanical seal integrity and material compatibility inspection for contamination pathways
    Check: Mechanical seal integrity and material compatibility inspection for contamination pathways
  • Area: Gasket and seal condition check for deterioration, leakage, and sanitary separation effectiveness
    Check: Gasket and seal condition check for deterioration, leakage, and sanitary separation effectiveness
  • Area: Bearing lubrication level and oil condition (viscosity, contamination, moisture content)
    Check: Bearing lubrication level and oil condition (viscosity, contamination, moisture content)
  • Area: Coupling alignment, wear, and guard integrity verification
    Check: Coupling alignment, wear, and guard integrity verification
  • Area: Suction and discharge line pressure and temperature monitoring for abnormal operation
    Check: Suction and discharge line pressure and temperature monitoring for abnormal operation

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

SPX FLOW / Celeros Flow Technology TRIRO Three Screw Pump - C6000 Range
TRIRO Three Screw Pump - C6000 Range ✓ verified
Application
Clean lubricating liquid transfer; lubricating oils, fuel oils and derivatives; process applications for additives, grease, bitumen/asphalt
Common Failures & Inspection Points
  • Area: Rotor-to-rotor clearance measurement and wear tolerance verification against OEM specifications
    Check: Rotor-to-rotor clearance measurement and wear tolerance verification against OEM specifications
  • Area: Rotor-to-casing clearance inspection using feeler gauges to detect excessive wear and internal slip
    Check: Rotor-to-casing clearance inspection using feeler gauges to detect excessive wear and internal slip
  • Area: Timing gear condition assessment and backlash measurement
    Check: Timing gear condition assessment and backlash measurement
  • Area: Mechanical seal integrity and material compatibility inspection for contamination pathways
    Check: Mechanical seal integrity and material compatibility inspection for contamination pathways
  • Area: Gasket and seal condition check for deterioration, leakage, and sanitary separation effectiveness
    Check: Gasket and seal condition check for deterioration, leakage, and sanitary separation effectiveness
  • Area: Bearing lubrication level and oil condition (viscosity, contamination, moisture content)
    Check: Bearing lubrication level and oil condition (viscosity, contamination, moisture content)
  • Area: Coupling alignment, wear, and guard integrity verification
    Check: Coupling alignment, wear, and guard integrity verification
  • Area: Suction and discharge line pressure and temperature monitoring for abnormal operation
    Check: Suction and discharge line pressure and temperature monitoring for abnormal operation

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

SPX FLOW / Celeros Flow Technology TRIRO Three Screw Pump - Marine
TRIRO Three Screw Pump - Marine ✓ verified
Application
Heavy fuel oil and fuel transfer in marine environments; marine lubrication and bunkering
Common Failures & Inspection Points
  • Area: Rotor-to-rotor clearance measurement and wear tolerance verification against OEM specifications
    Check: Rotor-to-rotor clearance measurement and wear tolerance verification against OEM specifications
  • Area: Rotor-to-casing clearance inspection using feeler gauges to detect excessive wear and internal slip
    Check: Rotor-to-casing clearance inspection using feeler gauges to detect excessive wear and internal slip
  • Area: Timing gear condition assessment and backlash measurement
    Check: Timing gear condition assessment and backlash measurement
  • Area: Mechanical seal integrity and material compatibility inspection for contamination pathways
    Check: Mechanical seal integrity and material compatibility inspection for contamination pathways
  • Area: Gasket and seal condition check for deterioration, leakage, and sanitary separation effectiveness
    Check: Gasket and seal condition check for deterioration, leakage, and sanitary separation effectiveness
  • Area: Bearing lubrication level and oil condition (viscosity, contamination, moisture content)
    Check: Bearing lubrication level and oil condition (viscosity, contamination, moisture content)
  • Area: Coupling alignment, wear, and guard integrity verification
    Check: Coupling alignment, wear, and guard integrity verification
  • Area: Suction and discharge line pressure and temperature monitoring for abnormal operation
    Check: Suction and discharge line pressure and temperature monitoring for abnormal operation

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

SPX FLOW / Celeros Flow Technology Twinro Two Screw Pump
Twinro Two Screw Pump ✓ verified
Application
Bulk transfer of lubricating and non-lubricating liquids; petroleum products, palm oils, fatty acids, water emulsions, lube oils, fuel oils
Common Failures & Inspection Points
  • Area: Rotor-to-rotor clearance measurement and wear tolerance verification against OEM specifications
    Check: Rotor-to-rotor clearance measurement and wear tolerance verification against OEM specifications
  • Area: Rotor-to-casing clearance inspection using feeler gauges to detect excessive wear and internal slip
    Check: Rotor-to-casing clearance inspection using feeler gauges to detect excessive wear and internal slip
  • Area: Timing gear condition assessment and backlash measurement
    Check: Timing gear condition assessment and backlash measurement
  • Area: Mechanical seal integrity and material compatibility inspection for contamination pathways
    Check: Mechanical seal integrity and material compatibility inspection for contamination pathways
  • Area: Gasket and seal condition check for deterioration, leakage, and sanitary separation effectiveness
    Check: Gasket and seal condition check for deterioration, leakage, and sanitary separation effectiveness
  • Area: Bearing lubrication level and oil condition (viscosity, contamination, moisture content)
    Check: Bearing lubrication level and oil condition (viscosity, contamination, moisture content)
  • Area: Coupling alignment, wear, and guard integrity verification
    Check: Coupling alignment, wear, and guard integrity verification
  • Area: Suction and discharge line pressure and temperature monitoring for abnormal operation
    Check: Suction and discharge line pressure and temperature monitoring for abnormal operation

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

DESMI

6 ✓ 1 verified
DESMI DESMI ROTAN GP 50
DESMI ROTAN GP 50 unverified
· 1.5 kW · fuel oil
Pump Type
screw
Flow (m³/h)
5
Power (kW)
1.5
Medium
fuel oil
DESMI DESMI ROTAN GP 100
DESMI ROTAN GP 100 unverified
· 3.0 kW · fuel oil
Pump Type
screw
Flow (m³/h)
10
Power (kW)
3.0
Medium
fuel oil
DESMI DESMI ROTAN GP 200
DESMI ROTAN GP 200 unverified
· 5.5 kW · fuel oil
Pump Type
screw
Flow (m³/h)
20
Power (kW)
5.5
Medium
fuel oil
DESMI DESMI ROTAN GG 80
DESMI ROTAN GG 80 unverified
· 2.2 kW · lube oil
Pump Type
screw
Flow (m³/h)
8
Power (kW)
2.2
Medium
lube oil
DESMI DESMI ROTAN GG 160
DESMI ROTAN GG 160 unverified
· 4.0 kW · lube oil
Pump Type
screw
Flow (m³/h)
16
Power (kW)
4.0
Medium
lube oil
DESMI K-Series Triple Screw Pump (KF/KH/KV variants)
K-Series Triple Screw Pump (KF/KH/KV variants) ✓ verified
Application
Industrial fluid transfer - Clean, non-abrasive liquids, fuel, diesel, gas, lube oil
Common Failures & Inspection Points
  • Area: Suction and discharge line pressures and vibration levels during operation to detect cavitation or excessive wear
    Check: Suction and discharge line pressures and vibration levels during operation to detect cavitation or excessive wear
  • Area: Seal condition and leakage rates at shaft seals and gland packings for evidence of degradation
    Check: Seal condition and leakage rates at shaft seals and gland packings for evidence of degradation
  • Area: Oil level and condition in bearing housings; check for emulsification, contamination, or thermal discoloration
    Check: Oil level and condition in bearing housings; check for emulsification, contamination, or thermal discoloration
  • Area: Pump outlet flow rate and temperature rise to verify performance against published curves and identify blockages
    Check: Pump outlet flow rate and temperature rise to verify performance against published curves and identify blockages
  • Area: Suction strainer or inlet screen differential pressure and cleanliness of internal components
    Check: Suction strainer or inlet screen differential pressure and cleanliness of internal components
  • Area: Bearing noise and vibration signature using ultrasonic or accelerometer equipment; compare baseline measurements
    Check: Bearing noise and vibration signature using ultrasonic or accelerometer equipment; compare baseline measurements
  • Area: Coupling alignment, bolts, and flexible element condition if shaft-coupled to motor
    Check: Coupling alignment, bolts, and flexible element condition if shaft-coupled to motor
  • Area: Casings, impellers (or screws for screw pumps), and internal wear plates for erosion, corrosion, or mechanical damage
    Check: Casings, impellers (or screws for screw pumps), and internal wear plates for erosion, corrosion, or mechanical damage

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

Leistritz

5 ✓ 5 verified
Leistritz L2 Series
L2 Series ✓ verified
Application
Twin-screw, low-pressure positive displacement pump for slightly aggressive, slightly abrasive, low to high-viscosity fluids with good or poor lubricity. Suitable for asphalt pumping, heavy fuel oils, lube oils.
Common Failures & Inspection Points
  • Area: Lagerung und Lagerspiel pruefen - Lagerverschleiß und axiales/radiales Spiel kontrollieren
    Check: Lagerung und Lagerspiel pruefen - Lagerverschleiß und axiales/radiales Spiel kontrollieren
  • Area: Wellendichtung/Simmerring pruefen - Undichtigkeiten, Verschleiß und Funktionsfaehigkeit ueberpruefen
    Check: Wellendichtung/Simmerring pruefen - Undichtigkeiten, Verschleiß und Funktionsfaehigkeit ueberpruefen
  • Area: Rotoren auf Verschleiß und Beschaedigungen pruefen - Oberflaeche, Zahnflanken und Ecken inspizieren
    Check: Rotoren auf Verschleiß und Beschaedigungen pruefen - Oberflaeche, Zahnflanken und Ecken inspizieren
  • Area: Druckregelventil und Sicherheitsventil pruefen - Ansprechen, Dichtheit und Funktionsfaehigkeit ueberpruefen
    Check: Druckregelventil und Sicherheitsventil pruefen - Ansprechen, Dichtheit und Funktionsfaehigkeit ueberpruefen
  • Area: Oelstand und Oelqualitaet pruefen - Viskositaet, Verschmutzungsgrad und Abrasivanteil pruefen
    Check: Oelstand und Oelqualitaet pruefen - Viskositaet, Verschmutzungsgrad und Abrasivanteil pruefen
  • Area: Flanschverschraubungen und Dichtungen kontrollieren - Verschleiß, Korrosion, Undichtigkeiten, Schraubenfestigkeit
    Check: Flanschverschraubungen und Dichtungen kontrollieren - Verschleiß, Korrosion, Undichtigkeiten, Schraubenfestigkeit
  • Area: Vibrationen, Geraeusch und Temperaturverhalten pruefen - Ungewoehnliche Vibrationen, Lagergeraeusche, Uebertemperatur
    Check: Vibrationen, Geraeusch und Temperaturverhalten pruefen - Ungewoehnliche Vibrationen, Lagergeraeusche, Uebertemperatur
  • Area: Elektromotor und Kupplung pruefen - Lagerverschleiß, Fluchtung und Verschleiß der Kupplung kontrollieren
    Check: Elektromotor und Kupplung pruefen - Lagerverschleiß, Fluchtung und Verschleiß der Kupplung kontrollieren

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

Leistritz L3NG
L3NG ✓ verified
Application
Three-screw, low-pressure, self-priming positive displacement pump for non-abrasive lubricating fluids. Used for feed/booster pumps, transfer pumps, diesel and heavy fuel oil applications in shipbuilding.
Common Failures & Inspection Points
  • Area: Lagerung und Lagerspiel pruefen - Lagerverschleiß und axiales/radiales Spiel kontrollieren
    Check: Lagerung und Lagerspiel pruefen - Lagerverschleiß und axiales/radiales Spiel kontrollieren
  • Area: Wellendichtung/Simmerring pruefen - Undichtigkeiten, Verschleiß und Funktionsfaehigkeit ueberpruefen
    Check: Wellendichtung/Simmerring pruefen - Undichtigkeiten, Verschleiß und Funktionsfaehigkeit ueberpruefen
  • Area: Rotoren auf Verschleiß und Beschaedigungen pruefen - Oberflaeche, Zahnflanken und Ecken inspizieren
    Check: Rotoren auf Verschleiß und Beschaedigungen pruefen - Oberflaeche, Zahnflanken und Ecken inspizieren
  • Area: Druckregelventil und Sicherheitsventil pruefen - Ansprechen, Dichtheit und Funktionsfaehigkeit ueberpruefen
    Check: Druckregelventil und Sicherheitsventil pruefen - Ansprechen, Dichtheit und Funktionsfaehigkeit ueberpruefen
  • Area: Oelstand und Oelqualitaet pruefen - Viskositaet, Verschmutzungsgrad und Abrasivanteil pruefen
    Check: Oelstand und Oelqualitaet pruefen - Viskositaet, Verschmutzungsgrad und Abrasivanteil pruefen
  • Area: Flanschverschraubungen und Dichtungen kontrollieren - Verschleiß, Korrosion, Undichtigkeiten, Schraubenfestigkeit
    Check: Flanschverschraubungen und Dichtungen kontrollieren - Verschleiß, Korrosion, Undichtigkeiten, Schraubenfestigkeit
  • Area: Vibrationen, Geraeusch und Temperaturverhalten pruefen - Ungewoehnliche Vibrationen, Lagergeraeusche, Uebertemperatur
    Check: Vibrationen, Geraeusch und Temperaturverhalten pruefen - Ungewoehnliche Vibrationen, Lagergeraeusche, Uebertemperatur
  • Area: Elektromotor und Kupplung pruefen - Lagerverschleiß, Fluchtung und Verschleiß der Kupplung kontrollieren
    Check: Elektromotor und Kupplung pruefen - Lagerverschleiß, Fluchtung und Verschleiß der Kupplung kontrollieren

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

Leistritz L3HG
L3HG ✓ verified
Application
Three-screw, high-pressure, self-priming positive displacement pump for non-abrasive lubricating fluids.
Common Failures & Inspection Points
  • Area: Lagerung und Lagerspiel pruefen - Lagerverschleiß und axiales/radiales Spiel kontrollieren
    Check: Lagerung und Lagerspiel pruefen - Lagerverschleiß und axiales/radiales Spiel kontrollieren
  • Area: Wellendichtung/Simmerring pruefen - Undichtigkeiten, Verschleiß und Funktionsfaehigkeit ueberpruefen
    Check: Wellendichtung/Simmerring pruefen - Undichtigkeiten, Verschleiß und Funktionsfaehigkeit ueberpruefen
  • Area: Rotoren auf Verschleiß und Beschaedigungen pruefen - Oberflaeche, Zahnflanken und Ecken inspizieren
    Check: Rotoren auf Verschleiß und Beschaedigungen pruefen - Oberflaeche, Zahnflanken und Ecken inspizieren
  • Area: Druckregelventil und Sicherheitsventil pruefen - Ansprechen, Dichtheit und Funktionsfaehigkeit ueberpruefen
    Check: Druckregelventil und Sicherheitsventil pruefen - Ansprechen, Dichtheit und Funktionsfaehigkeit ueberpruefen
  • Area: Oelstand und Oelqualitaet pruefen - Viskositaet, Verschmutzungsgrad und Abrasivanteil pruefen
    Check: Oelstand und Oelqualitaet pruefen - Viskositaet, Verschmutzungsgrad und Abrasivanteil pruefen
  • Area: Flanschverschraubungen und Dichtungen kontrollieren - Verschleiß, Korrosion, Undichtigkeiten, Schraubenfestigkeit
    Check: Flanschverschraubungen und Dichtungen kontrollieren - Verschleiß, Korrosion, Undichtigkeiten, Schraubenfestigkeit
  • Area: Vibrationen, Geraeusch und Temperaturverhalten pruefen - Ungewoehnliche Vibrationen, Lagergeraeusche, Uebertemperatur
    Check: Vibrationen, Geraeusch und Temperaturverhalten pruefen - Ungewoehnliche Vibrationen, Lagergeraeusche, Uebertemperatur
  • Area: Elektromotor und Kupplung pruefen - Lagerverschleiß, Fluchtung und Verschleiß der Kupplung kontrollieren
    Check: Elektromotor und Kupplung pruefen - Lagerverschleiß, Fluchtung und Verschleiß der Kupplung kontrollieren

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

Leistritz L4MG410
L4MG410 ✓ verified
Application
Twin-screw, medium-pressure, double-volute pump for multiphase applications in upstream oil and gas. Handles gas-liquid mixtures with up to 95% gas content.
Common Failures & Inspection Points
  • Area: Lagerung und Lagerspiel pruefen - Lagerverschleiß und axiales/radiales Spiel kontrollieren
    Check: Lagerung und Lagerspiel pruefen - Lagerverschleiß und axiales/radiales Spiel kontrollieren
  • Area: Wellendichtung/Simmerring pruefen - Undichtigkeiten, Verschleiß und Funktionsfaehigkeit ueberpruefen
    Check: Wellendichtung/Simmerring pruefen - Undichtigkeiten, Verschleiß und Funktionsfaehigkeit ueberpruefen
  • Area: Rotoren auf Verschleiß und Beschaedigungen pruefen - Oberflaeche, Zahnflanken und Ecken inspizieren
    Check: Rotoren auf Verschleiß und Beschaedigungen pruefen - Oberflaeche, Zahnflanken und Ecken inspizieren
  • Area: Druckregelventil und Sicherheitsventil pruefen - Ansprechen, Dichtheit und Funktionsfaehigkeit ueberpruefen
    Check: Druckregelventil und Sicherheitsventil pruefen - Ansprechen, Dichtheit und Funktionsfaehigkeit ueberpruefen
  • Area: Oelstand und Oelqualitaet pruefen - Viskositaet, Verschmutzungsgrad und Abrasivanteil pruefen
    Check: Oelstand und Oelqualitaet pruefen - Viskositaet, Verschmutzungsgrad und Abrasivanteil pruefen
  • Area: Flanschverschraubungen und Dichtungen kontrollieren - Verschleiß, Korrosion, Undichtigkeiten, Schraubenfestigkeit
    Check: Flanschverschraubungen und Dichtungen kontrollieren - Verschleiß, Korrosion, Undichtigkeiten, Schraubenfestigkeit
  • Area: Vibrationen, Geraeusch und Temperaturverhalten pruefen - Ungewoehnliche Vibrationen, Lagergeraeusche, Uebertemperatur
    Check: Vibrationen, Geraeusch und Temperaturverhalten pruefen - Ungewoehnliche Vibrationen, Lagergeraeusche, Uebertemperatur
  • Area: Elektromotor und Kupplung pruefen - Lagerverschleiß, Fluchtung und Verschleiß der Kupplung kontrollieren
    Check: Elektromotor und Kupplung pruefen - Lagerverschleiß, Fluchtung und Verschleiß der Kupplung kontrollieren

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

Leistritz L5
L5 ✓ verified
Application
Five-screw, low-pressure, single-volute, self-priming positive displacement pump for aggressive, light-abrasive, low to high-viscosity fluids. Asphalt, heavy fuel oils, lube oils, specialty compounds.
Common Failures & Inspection Points
  • Area: Lagerung und Lagerspiel pruefen - Lagerverschleiß und axiales/radiales Spiel kontrollieren
    Check: Lagerung und Lagerspiel pruefen - Lagerverschleiß und axiales/radiales Spiel kontrollieren
  • Area: Wellendichtung/Simmerring pruefen - Undichtigkeiten, Verschleiß und Funktionsfaehigkeit ueberpruefen
    Check: Wellendichtung/Simmerring pruefen - Undichtigkeiten, Verschleiß und Funktionsfaehigkeit ueberpruefen
  • Area: Rotoren auf Verschleiß und Beschaedigungen pruefen - Oberflaeche, Zahnflanken und Ecken inspizieren
    Check: Rotoren auf Verschleiß und Beschaedigungen pruefen - Oberflaeche, Zahnflanken und Ecken inspizieren
  • Area: Druckregelventil und Sicherheitsventil pruefen - Ansprechen, Dichtheit und Funktionsfaehigkeit ueberpruefen
    Check: Druckregelventil und Sicherheitsventil pruefen - Ansprechen, Dichtheit und Funktionsfaehigkeit ueberpruefen
  • Area: Oelstand und Oelqualitaet pruefen - Viskositaet, Verschmutzungsgrad und Abrasivanteil pruefen
    Check: Oelstand und Oelqualitaet pruefen - Viskositaet, Verschmutzungsgrad und Abrasivanteil pruefen
  • Area: Flanschverschraubungen und Dichtungen kontrollieren - Verschleiß, Korrosion, Undichtigkeiten, Schraubenfestigkeit
    Check: Flanschverschraubungen und Dichtungen kontrollieren - Verschleiß, Korrosion, Undichtigkeiten, Schraubenfestigkeit
  • Area: Vibrationen, Geraeusch und Temperaturverhalten pruefen - Ungewoehnliche Vibrationen, Lagergeraeusche, Uebertemperatur
    Check: Vibrationen, Geraeusch und Temperaturverhalten pruefen - Ungewoehnliche Vibrationen, Lagergeraeusche, Uebertemperatur
  • Area: Elektromotor und Kupplung pruefen - Lagerverschleiß, Fluchtung und Verschleiß der Kupplung kontrollieren
    Check: Elektromotor und Kupplung pruefen - Lagerverschleiß, Fluchtung und Verschleiß der Kupplung kontrollieren

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

NETZSCH Pumps & Systems

4 ✓ 4 verified
NETZSCH Pumps & Systems NOTOS 2NS Two Screw Pump
NOTOS 2NS Two Screw Pump ✓ verified
Application
Light to heavy lubricating materials with medium to high viscosity; non-abrasive to slightly abrasive, corrosive and non-corrosive liquids; wastewater, chemicals, lubricants
Common Failures & Inspection Points
  • Area: Visuelle Kontrolle auf Undichtigkeiten an Wellendichtungen und Verbindungsstellen; Leckage-Status dokumentieren
    Check: Visuelle Kontrolle auf Undichtigkeiten an Wellendichtungen und Verbindungsstellen; Leckage-Status dokumentieren
  • Area: Ueberwachung von Vibration und Geraeusch - Änderungen können auf Verschleiß oder Lagerschaeden hindeuten
    Check: Ueberwachung von Vibration und Geraeusch - Änderungen können auf Verschleiß oder Lagerschaeden hindeuten
  • Area: Regelmassige Oelanalyse und Oelwechsel (typisch alle 1000 Betriebsstunden) zur Kontrolle von Verschleiß und Verschmutzung
    Check: Regelmassige Oelanalyse und Oelwechsel (typisch alle 1000 Betriebsstunden) zur Kontrolle von Verschleiß und Verschmutzung
  • Area: Kontrolle der Lagerflansche, Lager und Verschraubungen auf Verschleiß und lockere Befestigungen
    Check: Kontrolle der Lagerflansche, Lager und Verschraubungen auf Verschleiß und lockere Befestigungen
  • Area: Ueberpruefung von Druck- und Durchflussraten auf Abweichungen von Sollwerten - Anzeichen von inneren Undichtigkeiten
    Check: Ueberpruefung von Druck- und Durchflussraten auf Abweichungen von Sollwerten - Anzeichen von inneren Undichtigkeiten
  • Area: Sichtpruefung von Schraube, Buchse und Dichtungen auf Verschleißmuster oder Oberflächenschaden
    Check: Sichtpruefung von Schraube, Buchse und Dichtungen auf Verschleißmuster oder Oberflächenschaden
  • Area: Kontrolle der Betriebstemperatur und Mediumtemperatur - Abnormale Temperaturerhoehung deutet auf Reibungszunahme hin
    Check: Kontrolle der Betriebstemperatur und Mediumtemperatur - Abnormale Temperaturerhoehung deutet auf Reibungszunahme hin
  • Area: Routineinspektion der Wellendichtringe und Kartuschen-Dichtungen (besonders bei 2NSH hygienic line); doppelte Dichtungen pruefen
    Check: Routineinspektion der Wellendichtringe und Kartuschen-Dichtungen (besonders bei 2NSH hygienic line); doppelte Dichtungen pruefen

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

NETZSCH Pumps & Systems NOTOS 3NS Three Screw Pump
NOTOS 3NS Three Screw Pump ✓ verified
Application
Oil and gas, lubrication, fuel oil applications, slurry, fuel, wastewater; LACT pipeline booster pumps
Common Failures & Inspection Points
  • Area: Visuelle Kontrolle auf Undichtigkeiten an Wellendichtungen und Verbindungsstellen; Leckage-Status dokumentieren
    Check: Visuelle Kontrolle auf Undichtigkeiten an Wellendichtungen und Verbindungsstellen; Leckage-Status dokumentieren
  • Area: Ueberwachung von Vibration und Geraeusch - Änderungen können auf Verschleiß oder Lagerschaeden hindeuten
    Check: Ueberwachung von Vibration und Geraeusch - Änderungen können auf Verschleiß oder Lagerschaeden hindeuten
  • Area: Regelmassige Oelanalyse und Oelwechsel (typisch alle 1000 Betriebsstunden) zur Kontrolle von Verschleiß und Verschmutzung
    Check: Regelmassige Oelanalyse und Oelwechsel (typisch alle 1000 Betriebsstunden) zur Kontrolle von Verschleiß und Verschmutzung
  • Area: Kontrolle der Lagerflansche, Lager und Verschraubungen auf Verschleiß und lockere Befestigungen
    Check: Kontrolle der Lagerflansche, Lager und Verschraubungen auf Verschleiß und lockere Befestigungen
  • Area: Ueberpruefung von Druck- und Durchflussraten auf Abweichungen von Sollwerten - Anzeichen von inneren Undichtigkeiten
    Check: Ueberpruefung von Druck- und Durchflussraten auf Abweichungen von Sollwerten - Anzeichen von inneren Undichtigkeiten
  • Area: Sichtpruefung von Schraube, Buchse und Dichtungen auf Verschleißmuster oder Oberflächenschaden
    Check: Sichtpruefung von Schraube, Buchse und Dichtungen auf Verschleißmuster oder Oberflächenschaden
  • Area: Kontrolle der Betriebstemperatur und Mediumtemperatur - Abnormale Temperaturerhoehung deutet auf Reibungszunahme hin
    Check: Kontrolle der Betriebstemperatur und Mediumtemperatur - Abnormale Temperaturerhoehung deutet auf Reibungszunahme hin
  • Area: Routineinspektion der Wellendichtringe und Kartuschen-Dichtungen (besonders bei 2NSH hygienic line); doppelte Dichtungen pruefen
    Check: Routineinspektion der Wellendichtringe und Kartuschen-Dichtungen (besonders bei 2NSH hygienic line); doppelte Dichtungen pruefen

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

NETZSCH Pumps & Systems NOTOS 4NS Geared Twin Screw Pump
NOTOS 4NS Geared Twin Screw Pump ✓ verified
Application
Asphalt handling, tank farms, power generation, shipping, process industry; wastewater, chemicals; high flow capacity applications
Common Failures & Inspection Points
  • Area: Visuelle Kontrolle auf Undichtigkeiten an Wellendichtungen und Verbindungsstellen; Leckage-Status dokumentieren
    Check: Visuelle Kontrolle auf Undichtigkeiten an Wellendichtungen und Verbindungsstellen; Leckage-Status dokumentieren
  • Area: Ueberwachung von Vibration und Geraeusch - Änderungen können auf Verschleiß oder Lagerschaeden hindeuten
    Check: Ueberwachung von Vibration und Geraeusch - Änderungen können auf Verschleiß oder Lagerschaeden hindeuten
  • Area: Regelmassige Oelanalyse und Oelwechsel (typisch alle 1000 Betriebsstunden) zur Kontrolle von Verschleiß und Verschmutzung
    Check: Regelmassige Oelanalyse und Oelwechsel (typisch alle 1000 Betriebsstunden) zur Kontrolle von Verschleiß und Verschmutzung
  • Area: Kontrolle der Lagerflansche, Lager und Verschraubungen auf Verschleiß und lockere Befestigungen
    Check: Kontrolle der Lagerflansche, Lager und Verschraubungen auf Verschleiß und lockere Befestigungen
  • Area: Ueberpruefung von Druck- und Durchflussraten auf Abweichungen von Sollwerten - Anzeichen von inneren Undichtigkeiten
    Check: Ueberpruefung von Druck- und Durchflussraten auf Abweichungen von Sollwerten - Anzeichen von inneren Undichtigkeiten
  • Area: Sichtpruefung von Schraube, Buchse und Dichtungen auf Verschleißmuster oder Oberflächenschaden
    Check: Sichtpruefung von Schraube, Buchse und Dichtungen auf Verschleißmuster oder Oberflächenschaden
  • Area: Kontrolle der Betriebstemperatur und Mediumtemperatur - Abnormale Temperaturerhoehung deutet auf Reibungszunahme hin
    Check: Kontrolle der Betriebstemperatur und Mediumtemperatur - Abnormale Temperaturerhoehung deutet auf Reibungszunahme hin
  • Area: Routineinspektion der Wellendichtringe und Kartuschen-Dichtungen (besonders bei 2NSH hygienic line); doppelte Dichtungen pruefen
    Check: Routineinspektion der Wellendichtringe und Kartuschen-Dichtungen (besonders bei 2NSH hygienic line); doppelte Dichtungen pruefen

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

NETZSCH Pumps & Systems NOTOS 2NSH Hygienic Twin Screw Pump
NOTOS 2NSH Hygienic Twin Screw Pump ✓ verified
Application
Food industry, pharmaceutical, hygienic applications, chocolate, fruit juices, yoghurt, chemicals, food products
Common Failures & Inspection Points
  • Area: Visuelle Kontrolle auf Undichtigkeiten an Wellendichtungen und Verbindungsstellen; Leckage-Status dokumentieren
    Check: Visuelle Kontrolle auf Undichtigkeiten an Wellendichtungen und Verbindungsstellen; Leckage-Status dokumentieren
  • Area: Ueberwachung von Vibration und Geraeusch - Änderungen können auf Verschleiß oder Lagerschaeden hindeuten
    Check: Ueberwachung von Vibration und Geraeusch - Änderungen können auf Verschleiß oder Lagerschaeden hindeuten
  • Area: Regelmassige Oelanalyse und Oelwechsel (typisch alle 1000 Betriebsstunden) zur Kontrolle von Verschleiß und Verschmutzung
    Check: Regelmassige Oelanalyse und Oelwechsel (typisch alle 1000 Betriebsstunden) zur Kontrolle von Verschleiß und Verschmutzung
  • Area: Kontrolle der Lagerflansche, Lager und Verschraubungen auf Verschleiß und lockere Befestigungen
    Check: Kontrolle der Lagerflansche, Lager und Verschraubungen auf Verschleiß und lockere Befestigungen
  • Area: Ueberpruefung von Druck- und Durchflussraten auf Abweichungen von Sollwerten - Anzeichen von inneren Undichtigkeiten
    Check: Ueberpruefung von Druck- und Durchflussraten auf Abweichungen von Sollwerten - Anzeichen von inneren Undichtigkeiten
  • Area: Sichtpruefung von Schraube, Buchse und Dichtungen auf Verschleißmuster oder Oberflächenschaden
    Check: Sichtpruefung von Schraube, Buchse und Dichtungen auf Verschleißmuster oder Oberflächenschaden
  • Area: Kontrolle der Betriebstemperatur und Mediumtemperatur - Abnormale Temperaturerhoehung deutet auf Reibungszunahme hin
    Check: Kontrolle der Betriebstemperatur und Mediumtemperatur - Abnormale Temperaturerhoehung deutet auf Reibungszunahme hin
  • Area: Routineinspektion der Wellendichtringe und Kartuschen-Dichtungen (besonders bei 2NSH hygienic line); doppelte Dichtungen pruefen
    Check: Routineinspektion der Wellendichtringe und Kartuschen-Dichtungen (besonders bei 2NSH hygienic line); doppelte Dichtungen pruefen

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

Flowserve

2 ✓ 2 verified
Flowserve TSP (Twin Screw Pump)
TSP (Twin Screw Pump) ✓ verified
Application
Crude oil handling, high viscosity fluids, cargo loading/unloading, polymers
Common Failures & Inspection Points
  • Area: Check coupling alignment and verify foundation bolts are properly torqued
    Check: Check coupling alignment and verify foundation bolts are properly torqued
  • Area: Inspect shaft seal condition daily and check for leakage
    Check: Inspect shaft seal condition daily and check for leakage
  • Area: Examine and clean suction strainer regularly; monitor pressure differential
    Check: Examine and clean suction strainer regularly; monitor pressure differential
  • Area: Inspect mechanical seal faces for wear, erosion, or damage during maintenance
    Check: Inspect mechanical seal faces for wear, erosion, or damage during maintenance
  • Area: Check bearing oil level and analyze oil condition for contamination
    Check: Check bearing oil level and analyze oil condition for contamination
  • Area: Monitor bearing temperature and listen for abnormal noise
    Check: Monitor bearing temperature and listen for abnormal noise
  • Area: Verify discharge pressure and flow rate against design specifications
    Check: Verify discharge pressure and flow rate against design specifications
  • Area: Monitor vibration levels as early warning of bearing or seal failure
    Check: Monitor vibration levels as early warning of bearing or seal failure

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

Flowserve MP1 (Multiphase Twin Screw Pump family)
MP1 (Multiphase Twin Screw Pump family) ✓ verified
Application
Multiphase crude oil, gas-liquid-solids mixtures, high viscosity applications
Common Failures & Inspection Points
  • Area: Check coupling alignment and verify foundation bolts are properly torqued
    Check: Check coupling alignment and verify foundation bolts are properly torqued
  • Area: Inspect shaft seal condition daily and check for leakage
    Check: Inspect shaft seal condition daily and check for leakage
  • Area: Examine and clean suction strainer regularly; monitor pressure differential
    Check: Examine and clean suction strainer regularly; monitor pressure differential
  • Area: Inspect mechanical seal faces for wear, erosion, or damage during maintenance
    Check: Inspect mechanical seal faces for wear, erosion, or damage during maintenance
  • Area: Check bearing oil level and analyze oil condition for contamination
    Check: Check bearing oil level and analyze oil condition for contamination
  • Area: Monitor bearing temperature and listen for abnormal noise
    Check: Monitor bearing temperature and listen for abnormal noise
  • Area: Verify discharge pressure and flow rate against design specifications
    Check: Verify discharge pressure and flow rate against design specifications
  • Area: Monitor vibration levels as early warning of bearing or seal failure
    Check: Monitor vibration levels as early warning of bearing or seal failure

Typ-universelle Inspektionspunkte fuer Pumps (verifiziert, 2026-06).

IMO AB (Colfax)

208
IMO AB (Colfax) IMO ACE Series
IMO ACE Series unverified
Model Family
ACE
Pump Type
3-screw
Application
fuel
IMO AB (Colfax) IMO ACE 1e6
IMO ACE 1e6 unverified
Model Family
ACE
Pump Type
3-screw
Flow Rate (m³/h)
1
Pressure (bar)
6
Application
fuel
IMO AB (Colfax) IMO ACE 1e10
IMO ACE 1e10 unverified
Model Family
ACE
Pump Type
3-screw
Flow Rate (m³/h)
1
Pressure (bar)
10
Application
fuel
IMO AB (Colfax) IMO ACE 1e16
IMO ACE 1e16 unverified
Model Family
ACE
Pump Type
3-screw
Flow Rate (m³/h)
1
Pressure (bar)
16
Application
fuel
IMO AB (Colfax) IMO ACE 1e25
IMO ACE 1e25 unverified
Model Family
ACE
Pump Type
3-screw
Flow Rate (m³/h)
1
Pressure (bar)
25
Application
fuel
IMO AB (Colfax) IMO ACE 3e6
IMO ACE 3e6 unverified
Model Family
ACE
Pump Type
3-screw
Flow Rate (m³/h)
3
Pressure (bar)
6
Application
fuel
IMO AB (Colfax) IMO ACE 3e10
IMO ACE 3e10 unverified
Model Family
ACE
Pump Type
3-screw
Flow Rate (m³/h)
3
Pressure (bar)
10
Application
fuel
IMO AB (Colfax) IMO ACE 3e16
IMO ACE 3e16 unverified
Model Family
ACE
Pump Type
3-screw
Flow Rate (m³/h)
3
Pressure (bar)
16
Application
fuel
IMO AB (Colfax) IMO ACE 3e25
IMO ACE 3e25 unverified
Model Family
ACE
Pump Type
3-screw
Flow Rate (m³/h)
3
Pressure (bar)
25
Application
fuel
IMO AB (Colfax) IMO ACE 5e6
IMO ACE 5e6 unverified
Model Family
ACE
Pump Type
3-screw
Flow Rate (m³/h)
5
Pressure (bar)
6
Application
fuel
IMO AB (Colfax) IMO ACE 5e10
IMO ACE 5e10 unverified
Model Family
ACE
Pump Type
3-screw
Flow Rate (m³/h)
5
Pressure (bar)
10
Application
fuel
IMO AB (Colfax) IMO ACE 5e16
IMO ACE 5e16 unverified
Model Family
ACE
Pump Type
3-screw
Flow Rate (m³/h)
5
Pressure (bar)
16
Application
fuel
IMO AB (Colfax) IMO ACE 5e25
IMO ACE 5e25 unverified
Model Family
ACE
Pump Type
3-screw
Flow Rate (m³/h)
5
Pressure (bar)
25
Application
fuel
IMO AB (Colfax) IMO ACE 10e6
IMO ACE 10e6 unverified
Model Family
ACE
Pump Type
3-screw
Flow Rate (m³/h)
10
Pressure (bar)
6
Application
fuel
IMO AB (Colfax) IMO ACE 10e10
IMO ACE 10e10 unverified
Model Family
ACE
Pump Type
3-screw
Flow Rate (m³/h)
10
Pressure (bar)
10
Application
fuel
IMO AB (Colfax) IMO ACE 10e16
IMO ACE 10e16 unverified
Model Family
ACE
Pump Type
3-screw
Flow Rate (m³/h)
10
Pressure (bar)
16
Application
fuel
IMO AB (Colfax) IMO ACE 10e25
IMO ACE 10e25 unverified
Model Family
ACE
Pump Type
3-screw
Flow Rate (m³/h)
10
Pressure (bar)
25
Application
fuel
IMO AB (Colfax) IMO ACE 25e6
IMO ACE 25e6 unverified
Model Family
ACE
Pump Type
3-screw
Flow Rate (m³/h)
25
Pressure (bar)
6
Application
fuel
IMO AB (Colfax) IMO ACE 25e10
IMO ACE 25e10 unverified
Model Family
ACE
Pump Type
3-screw
Flow Rate (m³/h)
25
Pressure (bar)
10
Application
fuel
IMO AB (Colfax) IMO ACE 25e16
IMO ACE 25e16 unverified
Model Family
ACE
Pump Type
3-screw
Flow Rate (m³/h)
25
Pressure (bar)
16
Application
fuel
IMO AB (Colfax) IMO ACE 25e25
IMO ACE 25e25 unverified
Model Family
ACE
Pump Type
3-screw
Flow Rate (m³/h)
25
Pressure (bar)
25
Application
fuel
IMO AB (Colfax) IMO ACE 50e6
IMO ACE 50e6 unverified
Model Family
ACE
Pump Type
3-screw
Flow Rate (m³/h)
50
Pressure (bar)
6
Application
fuel
IMO AB (Colfax) IMO ACE 50e10
IMO ACE 50e10 unverified
Model Family
ACE
Pump Type
3-screw
Flow Rate (m³/h)
50
Pressure (bar)
10
Application
fuel
IMO AB (Colfax) IMO ACE 50e16
IMO ACE 50e16 unverified
Model Family
ACE
Pump Type
3-screw
Flow Rate (m³/h)
50
Pressure (bar)
16
Application
fuel
IMO AB (Colfax) IMO ACE 50e25
IMO ACE 50e25 unverified
Model Family
ACE
Pump Type
3-screw
Flow Rate (m³/h)
50
Pressure (bar)
25
Application
fuel
IMO AB (Colfax) IMO ACE 100e6
IMO ACE 100e6 unverified
Model Family
ACE
Pump Type
3-screw
Flow Rate (m³/h)
100
Pressure (bar)
6
Application
fuel
IMO AB (Colfax) IMO ACE 100e10
IMO ACE 100e10 unverified
Model Family
ACE
Pump Type
3-screw
Flow Rate (m³/h)
100
Pressure (bar)
10
Application
fuel
IMO AB (Colfax) IMO ACE 100e16
IMO ACE 100e16 unverified
Model Family
ACE
Pump Type
3-screw
Flow Rate (m³/h)
100
Pressure (bar)
16
Application
fuel
IMO AB (Colfax) IMO ACE 100e25
IMO ACE 100e25 unverified
Model Family
ACE
Pump Type
3-screw
Flow Rate (m³/h)
100
Pressure (bar)
25
Application
fuel
IMO AB (Colfax) IMO ACE 200e6
IMO ACE 200e6 unverified
Model Family
ACE
Pump Type
3-screw
Flow Rate (m³/h)
200
Pressure (bar)
6
Application
fuel
IMO AB (Colfax) IMO ACE 200e10
IMO ACE 200e10 unverified
Model Family
ACE
Pump Type
3-screw
Flow Rate (m³/h)
200
Pressure (bar)
10
Application
fuel
IMO AB (Colfax) IMO ACE 200e16
IMO ACE 200e16 unverified
Model Family
ACE
Pump Type
3-screw
Flow Rate (m³/h)
200
Pressure (bar)
16
Application
fuel
IMO AB (Colfax) IMO ACE 200e25
IMO ACE 200e25 unverified
Model Family
ACE
Pump Type
3-screw
Flow Rate (m³/h)
200
Pressure (bar)
25
Application
fuel
IMO AB (Colfax) IMO ACF Series
IMO ACF Series unverified
Model Family
ACF
Pump Type
3-screw
Application
fuel
IMO AB (Colfax) IMO ACF 1e6
IMO ACF 1e6 unverified
Model Family
ACF
Pump Type
3-screw
Flow Rate (m³/h)
1
Pressure (bar)
6
Application
fuel
IMO AB (Colfax) IMO ACF 1e10
IMO ACF 1e10 unverified
Model Family
ACF
Pump Type
3-screw
Flow Rate (m³/h)
1
Pressure (bar)
10
Application
fuel
IMO AB (Colfax) IMO ACF 1e16
IMO ACF 1e16 unverified
Model Family
ACF
Pump Type
3-screw
Flow Rate (m³/h)
1
Pressure (bar)
16
Application
fuel
IMO AB (Colfax) IMO ACF 1e25
IMO ACF 1e25 unverified
Model Family
ACF
Pump Type
3-screw
Flow Rate (m³/h)
1
Pressure (bar)
25
Application
fuel
IMO AB (Colfax) IMO ACF 3e6
IMO ACF 3e6 unverified
Model Family
ACF
Pump Type
3-screw
Flow Rate (m³/h)
3
Pressure (bar)
6
Application
fuel
IMO AB (Colfax) IMO ACF 3e10
IMO ACF 3e10 unverified
Model Family
ACF
Pump Type
3-screw
Flow Rate (m³/h)
3
Pressure (bar)
10
Application
fuel
IMO AB (Colfax) IMO ACF 3e16
IMO ACF 3e16 unverified
Model Family
ACF
Pump Type
3-screw
Flow Rate (m³/h)
3
Pressure (bar)
16
Application
fuel
IMO AB (Colfax) IMO ACF 3e25
IMO ACF 3e25 unverified
Model Family
ACF
Pump Type
3-screw
Flow Rate (m³/h)
3
Pressure (bar)
25
Application
fuel
IMO AB (Colfax) IMO ACF 5e6
IMO ACF 5e6 unverified
Model Family
ACF
Pump Type
3-screw
Flow Rate (m³/h)
5
Pressure (bar)
6
Application
fuel
IMO AB (Colfax) IMO ACF 5e10
IMO ACF 5e10 unverified
Model Family
ACF
Pump Type
3-screw
Flow Rate (m³/h)
5
Pressure (bar)
10
Application
fuel
IMO AB (Colfax) IMO ACF 5e16
IMO ACF 5e16 unverified
Model Family
ACF
Pump Type
3-screw
Flow Rate (m³/h)
5
Pressure (bar)
16
Application
fuel
IMO AB (Colfax) IMO ACF 5e25
IMO ACF 5e25 unverified
Model Family
ACF
Pump Type
3-screw
Flow Rate (m³/h)
5
Pressure (bar)
25
Application
fuel
IMO AB (Colfax) IMO ACF 10e6
IMO ACF 10e6 unverified
Model Family
ACF
Pump Type
3-screw
Flow Rate (m³/h)
10
Pressure (bar)
6
Application
fuel
IMO AB (Colfax) IMO ACF 10e10
IMO ACF 10e10 unverified
Model Family
ACF
Pump Type
3-screw
Flow Rate (m³/h)
10
Pressure (bar)
10
Application
fuel
IMO AB (Colfax) IMO ACF 10e16
IMO ACF 10e16 unverified
Model Family
ACF
Pump Type
3-screw
Flow Rate (m³/h)
10
Pressure (bar)
16
Application
fuel
IMO AB (Colfax) IMO ACF 10e25
IMO ACF 10e25 unverified
Model Family
ACF
Pump Type
3-screw
Flow Rate (m³/h)
10
Pressure (bar)
25
Application
fuel
IMO AB (Colfax) IMO ACF 25e6
IMO ACF 25e6 unverified
Model Family
ACF
Pump Type
3-screw
Flow Rate (m³/h)
25
Pressure (bar)
6
Application
fuel
IMO AB (Colfax) IMO ACF 25e10
IMO ACF 25e10 unverified
Model Family
ACF
Pump Type
3-screw
Flow Rate (m³/h)
25
Pressure (bar)
10
Application
fuel
IMO AB (Colfax) IMO ACF 25e16
IMO ACF 25e16 unverified
Model Family
ACF
Pump Type
3-screw
Flow Rate (m³/h)
25
Pressure (bar)
16
Application
fuel
IMO AB (Colfax) IMO ACF 25e25
IMO ACF 25e25 unverified
Model Family
ACF
Pump Type
3-screw
Flow Rate (m³/h)
25
Pressure (bar)
25
Application
fuel
IMO AB (Colfax) IMO ACF 50e6
IMO ACF 50e6 unverified
Model Family
ACF
Pump Type
3-screw
Flow Rate (m³/h)
50
Pressure (bar)
6
Application
fuel
IMO AB (Colfax) IMO ACF 50e10
IMO ACF 50e10 unverified
Model Family
ACF
Pump Type
3-screw
Flow Rate (m³/h)
50
Pressure (bar)
10
Application
fuel
IMO AB (Colfax) IMO ACF 50e16
IMO ACF 50e16 unverified
Model Family
ACF
Pump Type
3-screw
Flow Rate (m³/h)
50
Pressure (bar)
16
Application
fuel
IMO AB (Colfax) IMO ACF 50e25
IMO ACF 50e25 unverified
Model Family
ACF
Pump Type
3-screw
Flow Rate (m³/h)
50
Pressure (bar)
25
Application
fuel
IMO AB (Colfax) IMO ACF 100e6
IMO ACF 100e6 unverified
Model Family
ACF
Pump Type
3-screw
Flow Rate (m³/h)
100
Pressure (bar)
6
Application
fuel
IMO AB (Colfax) IMO ACF 100e10
IMO ACF 100e10 unverified
Model Family
ACF
Pump Type
3-screw
Flow Rate (m³/h)
100
Pressure (bar)
10
Application
fuel
IMO AB (Colfax) IMO ACF 100e16
IMO ACF 100e16 unverified
Model Family
ACF
Pump Type
3-screw
Flow Rate (m³/h)
100
Pressure (bar)
16
Application
fuel
IMO AB (Colfax) IMO ACF 100e25
IMO ACF 100e25 unverified
Model Family
ACF
Pump Type
3-screw
Flow Rate (m³/h)
100
Pressure (bar)
25
Application
fuel
IMO AB (Colfax) IMO ACG Series
IMO ACG Series unverified
Model Family
ACG
Pump Type
3-screw
Application
lube
IMO AB (Colfax) IMO ACG 1e6
IMO ACG 1e6 unverified
Model Family
ACG
Pump Type
3-screw
Flow Rate (m³/h)
1
Pressure (bar)
6
Application
lube
IMO AB (Colfax) IMO ACG 1e10
IMO ACG 1e10 unverified
Model Family
ACG
Pump Type
3-screw
Flow Rate (m³/h)
1
Pressure (bar)
10
Application
lube
IMO AB (Colfax) IMO ACG 1e16
IMO ACG 1e16 unverified
Model Family
ACG
Pump Type
3-screw
Flow Rate (m³/h)
1
Pressure (bar)
16
Application
lube
IMO AB (Colfax) IMO ACG 1e25
IMO ACG 1e25 unverified
Model Family
ACG
Pump Type
3-screw
Flow Rate (m³/h)
1
Pressure (bar)
25
Application
lube
IMO AB (Colfax) IMO ACG 3e6
IMO ACG 3e6 unverified
Model Family
ACG
Pump Type
3-screw
Flow Rate (m³/h)
3
Pressure (bar)
6
Application
lube
IMO AB (Colfax) IMO ACG 3e10
IMO ACG 3e10 unverified
Model Family
ACG
Pump Type
3-screw
Flow Rate (m³/h)
3
Pressure (bar)
10
Application
lube
IMO AB (Colfax) IMO ACG 3e16
IMO ACG 3e16 unverified
Model Family
ACG
Pump Type
3-screw
Flow Rate (m³/h)
3
Pressure (bar)
16
Application
lube
IMO AB (Colfax) IMO ACG 3e25
IMO ACG 3e25 unverified
Model Family
ACG
Pump Type
3-screw
Flow Rate (m³/h)
3
Pressure (bar)
25
Application
lube
IMO AB (Colfax) IMO ACG 5e6
IMO ACG 5e6 unverified
Model Family
ACG
Pump Type
3-screw
Flow Rate (m³/h)
5
Pressure (bar)
6
Application
lube
IMO AB (Colfax) IMO ACG 5e10
IMO ACG 5e10 unverified
Model Family
ACG
Pump Type
3-screw
Flow Rate (m³/h)
5
Pressure (bar)
10
Application
lube
IMO AB (Colfax) IMO ACG 5e16
IMO ACG 5e16 unverified
Model Family
ACG
Pump Type
3-screw
Flow Rate (m³/h)
5
Pressure (bar)
16
Application
lube
IMO AB (Colfax) IMO ACG 5e25
IMO ACG 5e25 unverified
Model Family
ACG
Pump Type
3-screw
Flow Rate (m³/h)
5
Pressure (bar)
25
Application
lube
IMO AB (Colfax) IMO ACG 10e6
IMO ACG 10e6 unverified
Model Family
ACG
Pump Type
3-screw
Flow Rate (m³/h)
10
Pressure (bar)
6
Application
lube
IMO AB (Colfax) IMO ACG 10e10
IMO ACG 10e10 unverified
Model Family
ACG
Pump Type
3-screw
Flow Rate (m³/h)
10
Pressure (bar)
10
Application
lube
IMO AB (Colfax) IMO ACG 10e16
IMO ACG 10e16 unverified
Model Family
ACG
Pump Type
3-screw
Flow Rate (m³/h)
10
Pressure (bar)
16
Application
lube
IMO AB (Colfax) IMO ACG 10e25
IMO ACG 10e25 unverified
Model Family
ACG
Pump Type
3-screw
Flow Rate (m³/h)
10
Pressure (bar)
25
Application
lube
IMO AB (Colfax) IMO ACG 25e6
IMO ACG 25e6 unverified
Model Family
ACG
Pump Type
3-screw
Flow Rate (m³/h)
25
Pressure (bar)
6
Application
lube
IMO AB (Colfax) IMO ACG 25e10
IMO ACG 25e10 unverified
Model Family
ACG
Pump Type
3-screw
Flow Rate (m³/h)
25
Pressure (bar)
10
Application
lube
IMO AB (Colfax) IMO ACG 25e16
IMO ACG 25e16 unverified
Model Family
ACG
Pump Type
3-screw
Flow Rate (m³/h)
25
Pressure (bar)
16
Application
lube
IMO AB (Colfax) IMO ACG 25e25
IMO ACG 25e25 unverified
Model Family
ACG
Pump Type
3-screw
Flow Rate (m³/h)
25
Pressure (bar)
25
Application
lube
IMO AB (Colfax) IMO ACG 50e6
IMO ACG 50e6 unverified
Model Family
ACG
Pump Type
3-screw
Flow Rate (m³/h)
50
Pressure (bar)
6
Application
lube
IMO AB (Colfax) IMO ACG 50e10
IMO ACG 50e10 unverified
Model Family
ACG
Pump Type
3-screw
Flow Rate (m³/h)
50
Pressure (bar)
10
Application
lube
IMO AB (Colfax) IMO ACG 50e16
IMO ACG 50e16 unverified
Model Family
ACG
Pump Type
3-screw
Flow Rate (m³/h)
50
Pressure (bar)
16
Application
lube
IMO AB (Colfax) IMO ACG 50e25
IMO ACG 50e25 unverified
Model Family
ACG
Pump Type
3-screw
Flow Rate (m³/h)
50
Pressure (bar)
25
Application
lube
IMO AB (Colfax) IMO ACG 100e6
IMO ACG 100e6 unverified
Model Family
ACG
Pump Type
3-screw
Flow Rate (m³/h)
100
Pressure (bar)
6
Application
lube
IMO AB (Colfax) IMO ACG 100e10
IMO ACG 100e10 unverified
Model Family
ACG
Pump Type
3-screw
Flow Rate (m³/h)
100
Pressure (bar)
10
Application
lube
IMO AB (Colfax) IMO ACG 100e16
IMO ACG 100e16 unverified
Model Family
ACG
Pump Type
3-screw
Flow Rate (m³/h)
100
Pressure (bar)
16
Application
lube
IMO AB (Colfax) IMO ACG 100e25
IMO ACG 100e25 unverified
Model Family
ACG
Pump Type
3-screw
Flow Rate (m³/h)
100
Pressure (bar)
25
Application
lube
IMO AB (Colfax) IMO ACG 200e6
IMO ACG 200e6 unverified
Model Family
ACG
Pump Type
3-screw
Flow Rate (m³/h)
200
Pressure (bar)
6
Application
lube
IMO AB (Colfax) IMO ACG 200e10
IMO ACG 200e10 unverified
Model Family
ACG
Pump Type
3-screw
Flow Rate (m³/h)
200
Pressure (bar)
10
Application
lube
IMO AB (Colfax) IMO ACG 200e16
IMO ACG 200e16 unverified
Model Family
ACG
Pump Type
3-screw
Flow Rate (m³/h)
200
Pressure (bar)
16
Application
lube
IMO AB (Colfax) IMO ACG 200e25
IMO ACG 200e25 unverified
Model Family
ACG
Pump Type
3-screw
Flow Rate (m³/h)
200
Pressure (bar)
25
Application
lube
IMO AB (Colfax) IMO ACG 500e6
IMO ACG 500e6 unverified
Model Family
ACG
Pump Type
3-screw
Flow Rate (m³/h)
500
Pressure (bar)
6
Application
lube
IMO AB (Colfax) IMO ACG 500e10
IMO ACG 500e10 unverified
Model Family
ACG
Pump Type
3-screw
Flow Rate (m³/h)
500
Pressure (bar)
10
Application
lube
IMO AB (Colfax) IMO ACG 500e16
IMO ACG 500e16 unverified
Model Family
ACG
Pump Type
3-screw
Flow Rate (m³/h)
500
Pressure (bar)
16
Application
lube
IMO AB (Colfax) IMO ACG 500e25
IMO ACG 500e25 unverified
Model Family
ACG
Pump Type
3-screw
Flow Rate (m³/h)
500
Pressure (bar)
25
Application
lube
IMO AB (Colfax) IMO AMG Series
IMO AMG Series unverified
Model Family
AMG
Pump Type
3-screw
Application
lube
IMO AB (Colfax) IMO AMG 5e6
IMO AMG 5e6 unverified
Model Family
AMG
Pump Type
3-screw
Flow Rate (m³/h)
5
Pressure (bar)
6
Application
lube
IMO AB (Colfax) IMO AMG 5e10
IMO AMG 5e10 unverified
Model Family
AMG
Pump Type
3-screw
Flow Rate (m³/h)
5
Pressure (bar)
10
Application
lube
IMO AB (Colfax) IMO AMG 5e16
IMO AMG 5e16 unverified
Model Family
AMG
Pump Type
3-screw
Flow Rate (m³/h)
5
Pressure (bar)
16
Application
lube
IMO AB (Colfax) IMO AMG 5e25
IMO AMG 5e25 unverified
Model Family
AMG
Pump Type
3-screw
Flow Rate (m³/h)
5
Pressure (bar)
25
Application
lube
IMO AB (Colfax) IMO AMG 10e6
IMO AMG 10e6 unverified
Model Family
AMG
Pump Type
3-screw
Flow Rate (m³/h)
10
Pressure (bar)
6
Application
lube
IMO AB (Colfax) IMO AMG 10e10
IMO AMG 10e10 unverified
Model Family
AMG
Pump Type
3-screw
Flow Rate (m³/h)
10
Pressure (bar)
10
Application
lube
IMO AB (Colfax) IMO AMG 10e16
IMO AMG 10e16 unverified
Model Family
AMG
Pump Type
3-screw
Flow Rate (m³/h)
10
Pressure (bar)
16
Application
lube
IMO AB (Colfax) IMO AMG 10e25
IMO AMG 10e25 unverified
Model Family
AMG
Pump Type
3-screw
Flow Rate (m³/h)
10
Pressure (bar)
25
Application
lube
IMO AB (Colfax) IMO AMG 25e6
IMO AMG 25e6 unverified
Model Family
AMG
Pump Type
3-screw
Flow Rate (m³/h)
25
Pressure (bar)
6
Application
lube
IMO AB (Colfax) IMO AMG 25e10
IMO AMG 25e10 unverified
Model Family
AMG
Pump Type
3-screw
Flow Rate (m³/h)
25
Pressure (bar)
10
Application
lube
IMO AB (Colfax) IMO AMG 25e16
IMO AMG 25e16 unverified
Model Family
AMG
Pump Type
3-screw
Flow Rate (m³/h)
25
Pressure (bar)
16
Application
lube
IMO AB (Colfax) IMO AMG 25e25
IMO AMG 25e25 unverified
Model Family
AMG
Pump Type
3-screw
Flow Rate (m³/h)
25
Pressure (bar)
25
Application
lube
IMO AB (Colfax) IMO AMG 50e6
IMO AMG 50e6 unverified
Model Family
AMG
Pump Type
3-screw
Flow Rate (m³/h)
50
Pressure (bar)
6
Application
lube
IMO AB (Colfax) IMO AMG 50e10
IMO AMG 50e10 unverified
Model Family
AMG
Pump Type
3-screw
Flow Rate (m³/h)
50
Pressure (bar)
10
Application
lube
IMO AB (Colfax) IMO AMG 50e16
IMO AMG 50e16 unverified
Model Family
AMG
Pump Type
3-screw
Flow Rate (m³/h)
50
Pressure (bar)
16
Application
lube
IMO AB (Colfax) IMO AMG 50e25
IMO AMG 50e25 unverified
Model Family
AMG
Pump Type
3-screw
Flow Rate (m³/h)
50
Pressure (bar)
25
Application
lube
IMO AB (Colfax) IMO AMG 100e6
IMO AMG 100e6 unverified
Model Family
AMG
Pump Type
3-screw
Flow Rate (m³/h)
100
Pressure (bar)
6
Application
lube
IMO AB (Colfax) IMO AMG 100e10
IMO AMG 100e10 unverified
Model Family
AMG
Pump Type
3-screw
Flow Rate (m³/h)
100
Pressure (bar)
10
Application
lube
IMO AB (Colfax) IMO AMG 100e16
IMO AMG 100e16 unverified
Model Family
AMG
Pump Type
3-screw
Flow Rate (m³/h)
100
Pressure (bar)
16
Application
lube
IMO AB (Colfax) IMO AMG 100e25
IMO AMG 100e25 unverified
Model Family
AMG
Pump Type
3-screw
Flow Rate (m³/h)
100
Pressure (bar)
25
Application
lube
IMO AB (Colfax) IMO ARG Series
IMO ARG Series unverified
Model Family
ARG
Pump Type
3-screw
Application
fuel
IMO AB (Colfax) IMO ARG 5e6
IMO ARG 5e6 unverified
Model Family
ARG
Pump Type
3-screw
Flow Rate (m³/h)
5
Pressure (bar)
6
Application
fuel
IMO AB (Colfax) IMO ARG 5e10
IMO ARG 5e10 unverified
Model Family
ARG
Pump Type
3-screw
Flow Rate (m³/h)
5
Pressure (bar)
10
Application
fuel
IMO AB (Colfax) IMO ARG 5e16
IMO ARG 5e16 unverified
Model Family
ARG
Pump Type
3-screw
Flow Rate (m³/h)
5
Pressure (bar)
16
Application
fuel
IMO AB (Colfax) IMO ARG 5e25
IMO ARG 5e25 unverified
Model Family
ARG
Pump Type
3-screw
Flow Rate (m³/h)
5
Pressure (bar)
25
Application
fuel
IMO AB (Colfax) IMO ARG 10e6
IMO ARG 10e6 unverified
Model Family
ARG
Pump Type
3-screw
Flow Rate (m³/h)
10
Pressure (bar)
6
Application
fuel
IMO AB (Colfax) IMO ARG 10e10
IMO ARG 10e10 unverified
Model Family
ARG
Pump Type
3-screw
Flow Rate (m³/h)
10
Pressure (bar)
10
Application
fuel
IMO AB (Colfax) IMO ARG 10e16
IMO ARG 10e16 unverified
Model Family
ARG
Pump Type
3-screw
Flow Rate (m³/h)
10
Pressure (bar)
16
Application
fuel
IMO AB (Colfax) IMO ARG 10e25
IMO ARG 10e25 unverified
Model Family
ARG
Pump Type
3-screw
Flow Rate (m³/h)
10
Pressure (bar)
25
Application
fuel
IMO AB (Colfax) IMO ARG 25e6
IMO ARG 25e6 unverified
Model Family
ARG
Pump Type
3-screw
Flow Rate (m³/h)
25
Pressure (bar)
6
Application
fuel
IMO AB (Colfax) IMO ARG 25e10
IMO ARG 25e10 unverified
Model Family
ARG
Pump Type
3-screw
Flow Rate (m³/h)
25
Pressure (bar)
10
Application
fuel
IMO AB (Colfax) IMO ARG 25e16
IMO ARG 25e16 unverified
Model Family
ARG
Pump Type
3-screw
Flow Rate (m³/h)
25
Pressure (bar)
16
Application
fuel
IMO AB (Colfax) IMO ARG 25e25
IMO ARG 25e25 unverified
Model Family
ARG
Pump Type
3-screw
Flow Rate (m³/h)
25
Pressure (bar)
25
Application
fuel
IMO AB (Colfax) IMO ARG 50e6
IMO ARG 50e6 unverified
Model Family
ARG
Pump Type
3-screw
Flow Rate (m³/h)
50
Pressure (bar)
6
Application
fuel
IMO AB (Colfax) IMO ARG 50e10
IMO ARG 50e10 unverified
Model Family
ARG
Pump Type
3-screw
Flow Rate (m³/h)
50
Pressure (bar)
10
Application
fuel
IMO AB (Colfax) IMO ARG 50e16
IMO ARG 50e16 unverified
Model Family
ARG
Pump Type
3-screw
Flow Rate (m³/h)
50
Pressure (bar)
16
Application
fuel
IMO AB (Colfax) IMO ARG 50e25
IMO ARG 50e25 unverified
Model Family
ARG
Pump Type
3-screw
Flow Rate (m³/h)
50
Pressure (bar)
25
Application
fuel
IMO AB (Colfax) IMO ARG 100e6
IMO ARG 100e6 unverified
Model Family
ARG
Pump Type
3-screw
Flow Rate (m³/h)
100
Pressure (bar)
6
Application
fuel
IMO AB (Colfax) IMO ARG 100e10
IMO ARG 100e10 unverified
Model Family
ARG
Pump Type
3-screw
Flow Rate (m³/h)
100
Pressure (bar)
10
Application
fuel
IMO AB (Colfax) IMO ARG 100e16
IMO ARG 100e16 unverified
Model Family
ARG
Pump Type
3-screw
Flow Rate (m³/h)
100
Pressure (bar)
16
Application
fuel
IMO AB (Colfax) IMO ARG 100e25
IMO ARG 100e25 unverified
Model Family
ARG
Pump Type
3-screw
Flow Rate (m³/h)
100
Pressure (bar)
25
Application
fuel
IMO AB (Colfax) IMO ARG 200e6
IMO ARG 200e6 unverified
Model Family
ARG
Pump Type
3-screw
Flow Rate (m³/h)
200
Pressure (bar)
6
Application
fuel
IMO AB (Colfax) IMO ARG 200e10
IMO ARG 200e10 unverified
Model Family
ARG
Pump Type
3-screw
Flow Rate (m³/h)
200
Pressure (bar)
10
Application
fuel
IMO AB (Colfax) IMO ARG 200e16
IMO ARG 200e16 unverified
Model Family
ARG
Pump Type
3-screw
Flow Rate (m³/h)
200
Pressure (bar)
16
Application
fuel
IMO AB (Colfax) IMO ARG 200e25
IMO ARG 200e25 unverified
Model Family
ARG
Pump Type
3-screw
Flow Rate (m³/h)
200
Pressure (bar)
25
Application
fuel
IMO AB (Colfax) IMO AMH Series
IMO AMH Series unverified
Model Family
AMH
Pump Type
3-screw
Application
fuel
IMO AB (Colfax) IMO AMH 1e6
IMO AMH 1e6 unverified
Model Family
AMH
Pump Type
3-screw
Flow Rate (m³/h)
1
Pressure (bar)
6
Application
fuel
IMO AB (Colfax) IMO AMH 1e10
IMO AMH 1e10 unverified
Model Family
AMH
Pump Type
3-screw
Flow Rate (m³/h)
1
Pressure (bar)
10
Application
fuel
IMO AB (Colfax) IMO AMH 1e16
IMO AMH 1e16 unverified
Model Family
AMH
Pump Type
3-screw
Flow Rate (m³/h)
1
Pressure (bar)
16
Application
fuel
IMO AB (Colfax) IMO AMH 1e25
IMO AMH 1e25 unverified
Model Family
AMH
Pump Type
3-screw
Flow Rate (m³/h)
1
Pressure (bar)
25
Application
fuel
IMO AB (Colfax) IMO AMH 3e6
IMO AMH 3e6 unverified
Model Family
AMH
Pump Type
3-screw
Flow Rate (m³/h)
3
Pressure (bar)
6
Application
fuel
IMO AB (Colfax) IMO AMH 3e10
IMO AMH 3e10 unverified
Model Family
AMH
Pump Type
3-screw
Flow Rate (m³/h)
3
Pressure (bar)
10
Application
fuel
IMO AB (Colfax) IMO AMH 3e16
IMO AMH 3e16 unverified
Model Family
AMH
Pump Type
3-screw
Flow Rate (m³/h)
3
Pressure (bar)
16
Application
fuel
IMO AB (Colfax) IMO AMH 3e25
IMO AMH 3e25 unverified
Model Family
AMH
Pump Type
3-screw
Flow Rate (m³/h)
3
Pressure (bar)
25
Application
fuel
IMO AB (Colfax) IMO AMH 5e6
IMO AMH 5e6 unverified
Model Family
AMH
Pump Type
3-screw
Flow Rate (m³/h)
5
Pressure (bar)
6
Application
fuel
IMO AB (Colfax) IMO AMH 5e10
IMO AMH 5e10 unverified
Model Family
AMH
Pump Type
3-screw
Flow Rate (m³/h)
5
Pressure (bar)
10
Application
fuel
IMO AB (Colfax) IMO AMH 5e16
IMO AMH 5e16 unverified
Model Family
AMH
Pump Type
3-screw
Flow Rate (m³/h)
5
Pressure (bar)
16
Application
fuel
IMO AB (Colfax) IMO AMH 5e25
IMO AMH 5e25 unverified
Model Family
AMH
Pump Type
3-screw
Flow Rate (m³/h)
5
Pressure (bar)
25
Application
fuel
IMO AB (Colfax) IMO AMH 10e6
IMO AMH 10e6 unverified
Model Family
AMH
Pump Type
3-screw
Flow Rate (m³/h)
10
Pressure (bar)
6
Application
fuel
IMO AB (Colfax) IMO AMH 10e10
IMO AMH 10e10 unverified
Model Family
AMH
Pump Type
3-screw
Flow Rate (m³/h)
10
Pressure (bar)
10
Application
fuel
IMO AB (Colfax) IMO AMH 10e16
IMO AMH 10e16 unverified
Model Family
AMH
Pump Type
3-screw
Flow Rate (m³/h)
10
Pressure (bar)
16
Application
fuel
IMO AB (Colfax) IMO AMH 10e25
IMO AMH 10e25 unverified
Model Family
AMH
Pump Type
3-screw
Flow Rate (m³/h)
10
Pressure (bar)
25
Application
fuel
IMO AB (Colfax) IMO AMH 25e6
IMO AMH 25e6 unverified
Model Family
AMH
Pump Type
3-screw
Flow Rate (m³/h)
25
Pressure (bar)
6
Application
fuel
IMO AB (Colfax) IMO AMH 25e10
IMO AMH 25e10 unverified
Model Family
AMH
Pump Type
3-screw
Flow Rate (m³/h)
25
Pressure (bar)
10
Application
fuel
IMO AB (Colfax) IMO AMH 25e16
IMO AMH 25e16 unverified
Model Family
AMH
Pump Type
3-screw
Flow Rate (m³/h)
25
Pressure (bar)
16
Application
fuel
IMO AB (Colfax) IMO AMH 25e25
IMO AMH 25e25 unverified
Model Family
AMH
Pump Type
3-screw
Flow Rate (m³/h)
25
Pressure (bar)
25
Application
fuel
IMO AB (Colfax) IMO ACM Series
IMO ACM Series unverified
Model Family
ACM
Pump Type
3-screw
Application
lube
IMO AB (Colfax) IMO ACM 1e6
IMO ACM 1e6 unverified
Model Family
ACM
Pump Type
3-screw
Flow Rate (m³/h)
1
Pressure (bar)
6
Application
lube
IMO AB (Colfax) IMO ACM 1e10
IMO ACM 1e10 unverified
Model Family
ACM
Pump Type
3-screw
Flow Rate (m³/h)
1
Pressure (bar)
10
Application
lube
IMO AB (Colfax) IMO ACM 1e16
IMO ACM 1e16 unverified
Model Family
ACM
Pump Type
3-screw
Flow Rate (m³/h)
1
Pressure (bar)
16
Application
lube
IMO AB (Colfax) IMO ACM 1e25
IMO ACM 1e25 unverified
Model Family
ACM
Pump Type
3-screw
Flow Rate (m³/h)
1
Pressure (bar)
25
Application
lube
IMO AB (Colfax) IMO ACM 3e6
IMO ACM 3e6 unverified
Model Family
ACM
Pump Type
3-screw
Flow Rate (m³/h)
3
Pressure (bar)
6
Application
lube
IMO AB (Colfax) IMO ACM 3e10
IMO ACM 3e10 unverified
Model Family
ACM
Pump Type
3-screw
Flow Rate (m³/h)
3
Pressure (bar)
10
Application
lube
IMO AB (Colfax) IMO ACM 3e16
IMO ACM 3e16 unverified
Model Family
ACM
Pump Type
3-screw
Flow Rate (m³/h)
3
Pressure (bar)
16
Application
lube
IMO AB (Colfax) IMO ACM 3e25
IMO ACM 3e25 unverified
Model Family
ACM
Pump Type
3-screw
Flow Rate (m³/h)
3
Pressure (bar)
25
Application
lube
IMO AB (Colfax) IMO ACM 5e6
IMO ACM 5e6 unverified
Model Family
ACM
Pump Type
3-screw
Flow Rate (m³/h)
5
Pressure (bar)
6
Application
lube
IMO AB (Colfax) IMO ACM 5e10
IMO ACM 5e10 unverified
Model Family
ACM
Pump Type
3-screw
Flow Rate (m³/h)
5
Pressure (bar)
10
Application
lube
IMO AB (Colfax) IMO ACM 5e16
IMO ACM 5e16 unverified
Model Family
ACM
Pump Type
3-screw
Flow Rate (m³/h)
5
Pressure (bar)
16
Application
lube
IMO AB (Colfax) IMO ACM 5e25
IMO ACM 5e25 unverified
Model Family
ACM
Pump Type
3-screw
Flow Rate (m³/h)
5
Pressure (bar)
25
Application
lube
IMO AB (Colfax) IMO ACM 10e6
IMO ACM 10e6 unverified
Model Family
ACM
Pump Type
3-screw
Flow Rate (m³/h)
10
Pressure (bar)
6
Application
lube
IMO AB (Colfax) IMO ACM 10e10
IMO ACM 10e10 unverified
Model Family
ACM
Pump Type
3-screw
Flow Rate (m³/h)
10
Pressure (bar)
10
Application
lube
IMO AB (Colfax) IMO ACM 10e16
IMO ACM 10e16 unverified
Model Family
ACM
Pump Type
3-screw
Flow Rate (m³/h)
10
Pressure (bar)
16
Application
lube
IMO AB (Colfax) IMO ACM 10e25
IMO ACM 10e25 unverified
Model Family
ACM
Pump Type
3-screw
Flow Rate (m³/h)
10
Pressure (bar)
25
Application
lube
IMO AB (Colfax) IMO LMD Series
IMO LMD Series unverified
Model Family
LMD
Pump Type
3-screw
Application
fuel
IMO AB (Colfax) IMO LMD 10e6
IMO LMD 10e6 unverified
Model Family
LMD
Pump Type
3-screw
Flow Rate (m³/h)
10
Pressure (bar)
6
Application
fuel
IMO AB (Colfax) IMO LMD 10e10
IMO LMD 10e10 unverified
Model Family
LMD
Pump Type
3-screw
Flow Rate (m³/h)
10
Pressure (bar)
10
Application
fuel
IMO AB (Colfax) IMO LMD 10e16
IMO LMD 10e16 unverified
Model Family
LMD
Pump Type
3-screw
Flow Rate (m³/h)
10
Pressure (bar)
16
Application
fuel
IMO AB (Colfax) IMO LMD 10e25
IMO LMD 10e25 unverified
Model Family
LMD
Pump Type
3-screw
Flow Rate (m³/h)
10
Pressure (bar)
25
Application
fuel
IMO AB (Colfax) IMO LMD 25e6
IMO LMD 25e6 unverified
Model Family
LMD
Pump Type
3-screw
Flow Rate (m³/h)
25
Pressure (bar)
6
Application
fuel
IMO AB (Colfax) IMO LMD 25e10
IMO LMD 25e10 unverified
Model Family
LMD
Pump Type
3-screw
Flow Rate (m³/h)
25
Pressure (bar)
10
Application
fuel
IMO AB (Colfax) IMO LMD 25e16
IMO LMD 25e16 unverified
Model Family
LMD
Pump Type
3-screw
Flow Rate (m³/h)
25
Pressure (bar)
16
Application
fuel
IMO AB (Colfax) IMO LMD 25e25
IMO LMD 25e25 unverified
Model Family
LMD
Pump Type
3-screw
Flow Rate (m³/h)
25
Pressure (bar)
25
Application
fuel
IMO AB (Colfax) IMO LMD 50e6
IMO LMD 50e6 unverified
Model Family
LMD
Pump Type
3-screw
Flow Rate (m³/h)
50
Pressure (bar)
6
Application
fuel
IMO AB (Colfax) IMO LMD 50e10
IMO LMD 50e10 unverified
Model Family
LMD
Pump Type
3-screw
Flow Rate (m³/h)
50
Pressure (bar)
10
Application
fuel
IMO AB (Colfax) IMO LMD 50e16
IMO LMD 50e16 unverified
Model Family
LMD
Pump Type
3-screw
Flow Rate (m³/h)
50
Pressure (bar)
16
Application
fuel
IMO AB (Colfax) IMO LMD 50e25
IMO LMD 50e25 unverified
Model Family
LMD
Pump Type
3-screw
Flow Rate (m³/h)
50
Pressure (bar)
25
Application
fuel
IMO AB (Colfax) IMO LMD 100e6
IMO LMD 100e6 unverified
Model Family
LMD
Pump Type
3-screw
Flow Rate (m³/h)
100
Pressure (bar)
6
Application
fuel
IMO AB (Colfax) IMO LMD 100e10
IMO LMD 100e10 unverified
Model Family
LMD
Pump Type
3-screw
Flow Rate (m³/h)
100
Pressure (bar)
10
Application
fuel
IMO AB (Colfax) IMO LMD 100e16
IMO LMD 100e16 unverified
Model Family
LMD
Pump Type
3-screw
Flow Rate (m³/h)
100
Pressure (bar)
16
Application
fuel
IMO AB (Colfax) IMO LMD 100e25
IMO LMD 100e25 unverified
Model Family
LMD
Pump Type
3-screw
Flow Rate (m³/h)
100
Pressure (bar)
25
Application
fuel
IMO AB (Colfax) IMO LMD 200e6
IMO LMD 200e6 unverified
Model Family
LMD
Pump Type
3-screw
Flow Rate (m³/h)
200
Pressure (bar)
6
Application
fuel
IMO AB (Colfax) IMO LMD 200e10
IMO LMD 200e10 unverified
Model Family
LMD
Pump Type
3-screw
Flow Rate (m³/h)
200
Pressure (bar)
10
Application
fuel
IMO AB (Colfax) IMO LMD 200e16
IMO LMD 200e16 unverified
Model Family
LMD
Pump Type
3-screw
Flow Rate (m³/h)
200
Pressure (bar)
16
Application
fuel
IMO AB (Colfax) IMO LMD 200e25
IMO LMD 200e25 unverified
Model Family
LMD
Pump Type
3-screw
Flow Rate (m³/h)
200
Pressure (bar)
25
Application
fuel
IMO AB (Colfax) IMO LMD 500e6
IMO LMD 500e6 unverified
Model Family
LMD
Pump Type
3-screw
Flow Rate (m³/h)
500
Pressure (bar)
6
Application
fuel
IMO AB (Colfax) IMO LMD 500e10
IMO LMD 500e10 unverified
Model Family
LMD
Pump Type
3-screw
Flow Rate (m³/h)
500
Pressure (bar)
10
Application
fuel
IMO AB (Colfax) IMO LMD 500e16
IMO LMD 500e16 unverified
Model Family
LMD
Pump Type
3-screw
Flow Rate (m³/h)
500
Pressure (bar)
16
Application
fuel
IMO AB (Colfax) IMO LMD 500e25
IMO LMD 500e25 unverified
Model Family
LMD
Pump Type
3-screw
Flow Rate (m³/h)
500
Pressure (bar)
25
Application
fuel

Allweiler

143
Allweiler Allweiler ALLMARINE MI Series
Allweiler ALLMARINE MI Series unverified
Model Family
ALLMARINE MI
Pump Type
screw
Application
fuel
Allweiler Allweiler ALLMARINE MI 1-6
Allweiler ALLMARINE MI 1-6 unverified
Model Family
ALLMARINE MI
Pump Type
screw
Flow Rate (m³/h)
1
Pressure (bar)
6
Application
fuel
Allweiler Allweiler ALLMARINE MI 1-10
Allweiler ALLMARINE MI 1-10 unverified
Model Family
ALLMARINE MI
Pump Type
screw
Flow Rate (m³/h)
1
Pressure (bar)
10
Application
fuel
Allweiler Allweiler ALLMARINE MI 1-16
Allweiler ALLMARINE MI 1-16 unverified
Model Family
ALLMARINE MI
Pump Type
screw
Flow Rate (m³/h)
1
Pressure (bar)
16
Application
fuel
Allweiler Allweiler ALLMARINE MI 3-6
Allweiler ALLMARINE MI 3-6 unverified
Model Family
ALLMARINE MI
Pump Type
screw
Flow Rate (m³/h)
3
Pressure (bar)
6
Application
fuel
Allweiler Allweiler ALLMARINE MI 3-10
Allweiler ALLMARINE MI 3-10 unverified
Model Family
ALLMARINE MI
Pump Type
screw
Flow Rate (m³/h)
3
Pressure (bar)
10
Application
fuel
Allweiler Allweiler ALLMARINE MI 3-16
Allweiler ALLMARINE MI 3-16 unverified
Model Family
ALLMARINE MI
Pump Type
screw
Flow Rate (m³/h)
3
Pressure (bar)
16
Application
fuel
Allweiler Allweiler ALLMARINE MI 5-6
Allweiler ALLMARINE MI 5-6 unverified
Model Family
ALLMARINE MI
Pump Type
screw
Flow Rate (m³/h)
5
Pressure (bar)
6
Application
fuel
Allweiler Allweiler ALLMARINE MI 5-10
Allweiler ALLMARINE MI 5-10 unverified
Model Family
ALLMARINE MI
Pump Type
screw
Flow Rate (m³/h)
5
Pressure (bar)
10
Application
fuel
Allweiler Allweiler ALLMARINE MI 5-16
Allweiler ALLMARINE MI 5-16 unverified
Model Family
ALLMARINE MI
Pump Type
screw
Flow Rate (m³/h)
5
Pressure (bar)
16
Application
fuel
Allweiler Allweiler ALLMARINE MI 10-6
Allweiler ALLMARINE MI 10-6 unverified
Model Family
ALLMARINE MI
Pump Type
screw
Flow Rate (m³/h)
10
Pressure (bar)
6
Application
fuel
Allweiler Allweiler ALLMARINE MI 10-10
Allweiler ALLMARINE MI 10-10 unverified
Model Family
ALLMARINE MI
Pump Type
screw
Flow Rate (m³/h)
10
Pressure (bar)
10
Application
fuel
Allweiler Allweiler ALLMARINE MI 10-16
Allweiler ALLMARINE MI 10-16 unverified
Model Family
ALLMARINE MI
Pump Type
screw
Flow Rate (m³/h)
10
Pressure (bar)
16
Application
fuel
Allweiler Allweiler ALLMARINE MI 15-6
Allweiler ALLMARINE MI 15-6 unverified
Model Family
ALLMARINE MI
Pump Type
screw
Flow Rate (m³/h)
15
Pressure (bar)
6
Application
fuel
Allweiler Allweiler ALLMARINE MI 15-10
Allweiler ALLMARINE MI 15-10 unverified
Model Family
ALLMARINE MI
Pump Type
screw
Flow Rate (m³/h)
15
Pressure (bar)
10
Application
fuel
Allweiler Allweiler ALLMARINE MI 15-16
Allweiler ALLMARINE MI 15-16 unverified
Model Family
ALLMARINE MI
Pump Type
screw
Flow Rate (m³/h)
15
Pressure (bar)
16
Application
fuel
Allweiler Allweiler ALLMARINE MI 25-6
Allweiler ALLMARINE MI 25-6 unverified
Model Family
ALLMARINE MI
Pump Type
screw
Flow Rate (m³/h)
25
Pressure (bar)
6
Application
fuel
Allweiler Allweiler ALLMARINE MI 25-10
Allweiler ALLMARINE MI 25-10 unverified
Model Family
ALLMARINE MI
Pump Type
screw
Flow Rate (m³/h)
25
Pressure (bar)
10
Application
fuel
Allweiler Allweiler ALLMARINE MI 25-16
Allweiler ALLMARINE MI 25-16 unverified
Model Family
ALLMARINE MI
Pump Type
screw
Flow Rate (m³/h)
25
Pressure (bar)
16
Application
fuel
Allweiler Allweiler ALLMARINE MI 50-6
Allweiler ALLMARINE MI 50-6 unverified
Model Family
ALLMARINE MI
Pump Type
screw
Flow Rate (m³/h)
50
Pressure (bar)
6
Application
fuel
Allweiler Allweiler ALLMARINE MI 50-10
Allweiler ALLMARINE MI 50-10 unverified
Model Family
ALLMARINE MI
Pump Type
screw
Flow Rate (m³/h)
50
Pressure (bar)
10
Application
fuel
Allweiler Allweiler ALLMARINE MI 50-16
Allweiler ALLMARINE MI 50-16 unverified
Model Family
ALLMARINE MI
Pump Type
screw
Flow Rate (m³/h)
50
Pressure (bar)
16
Application
fuel
Allweiler Allweiler ALLMARINE MA Series
Allweiler ALLMARINE MA Series unverified
Model Family
ALLMARINE MA
Pump Type
screw
Application
lube
Allweiler Allweiler ALLMARINE MA 1-6
Allweiler ALLMARINE MA 1-6 unverified
Model Family
ALLMARINE MA
Pump Type
screw
Flow Rate (m³/h)
1
Pressure (bar)
6
Application
lube
Allweiler Allweiler ALLMARINE MA 1-10
Allweiler ALLMARINE MA 1-10 unverified
Model Family
ALLMARINE MA
Pump Type
screw
Flow Rate (m³/h)
1
Pressure (bar)
10
Application
lube
Allweiler Allweiler ALLMARINE MA 1-16
Allweiler ALLMARINE MA 1-16 unverified
Model Family
ALLMARINE MA
Pump Type
screw
Flow Rate (m³/h)
1
Pressure (bar)
16
Application
lube
Allweiler Allweiler ALLMARINE MA 3-6
Allweiler ALLMARINE MA 3-6 unverified
Model Family
ALLMARINE MA
Pump Type
screw
Flow Rate (m³/h)
3
Pressure (bar)
6
Application
lube
Allweiler Allweiler ALLMARINE MA 3-10
Allweiler ALLMARINE MA 3-10 unverified
Model Family
ALLMARINE MA
Pump Type
screw
Flow Rate (m³/h)
3
Pressure (bar)
10
Application
lube
Allweiler Allweiler ALLMARINE MA 3-16
Allweiler ALLMARINE MA 3-16 unverified
Model Family
ALLMARINE MA
Pump Type
screw
Flow Rate (m³/h)
3
Pressure (bar)
16
Application
lube
Allweiler Allweiler ALLMARINE MA 5-6
Allweiler ALLMARINE MA 5-6 unverified
Model Family
ALLMARINE MA
Pump Type
screw
Flow Rate (m³/h)
5
Pressure (bar)
6
Application
lube
Allweiler Allweiler ALLMARINE MA 5-10
Allweiler ALLMARINE MA 5-10 unverified
Model Family
ALLMARINE MA
Pump Type
screw
Flow Rate (m³/h)
5
Pressure (bar)
10
Application
lube
Allweiler Allweiler ALLMARINE MA 5-16
Allweiler ALLMARINE MA 5-16 unverified
Model Family
ALLMARINE MA
Pump Type
screw
Flow Rate (m³/h)
5
Pressure (bar)
16
Application
lube
Allweiler Allweiler ALLMARINE MA 10-6
Allweiler ALLMARINE MA 10-6 unverified
Model Family
ALLMARINE MA
Pump Type
screw
Flow Rate (m³/h)
10
Pressure (bar)
6
Application
lube
Allweiler Allweiler ALLMARINE MA 10-10
Allweiler ALLMARINE MA 10-10 unverified
Model Family
ALLMARINE MA
Pump Type
screw
Flow Rate (m³/h)
10
Pressure (bar)
10
Application
lube
Allweiler Allweiler ALLMARINE MA 10-16
Allweiler ALLMARINE MA 10-16 unverified
Model Family
ALLMARINE MA
Pump Type
screw
Flow Rate (m³/h)
10
Pressure (bar)
16
Application
lube
Allweiler Allweiler ALLMARINE MA 25-6
Allweiler ALLMARINE MA 25-6 unverified
Model Family
ALLMARINE MA
Pump Type
screw
Flow Rate (m³/h)
25
Pressure (bar)
6
Application
lube
Allweiler Allweiler ALLMARINE MA 25-10
Allweiler ALLMARINE MA 25-10 unverified
Model Family
ALLMARINE MA
Pump Type
screw
Flow Rate (m³/h)
25
Pressure (bar)
10
Application
lube
Allweiler Allweiler ALLMARINE MA 25-16
Allweiler ALLMARINE MA 25-16 unverified
Model Family
ALLMARINE MA
Pump Type
screw
Flow Rate (m³/h)
25
Pressure (bar)
16
Application
lube
Allweiler Allweiler ALLMARINE MA 50-6
Allweiler ALLMARINE MA 50-6 unverified
Model Family
ALLMARINE MA
Pump Type
screw
Flow Rate (m³/h)
50
Pressure (bar)
6
Application
lube
Allweiler Allweiler ALLMARINE MA 50-10
Allweiler ALLMARINE MA 50-10 unverified
Model Family
ALLMARINE MA
Pump Type
screw
Flow Rate (m³/h)
50
Pressure (bar)
10
Application
lube
Allweiler Allweiler ALLMARINE MA 50-16
Allweiler ALLMARINE MA 50-16 unverified
Model Family
ALLMARINE MA
Pump Type
screw
Flow Rate (m³/h)
50
Pressure (bar)
16
Application
lube
Allweiler Allweiler ALLMARINE MAH Series
Allweiler ALLMARINE MAH Series unverified
Model Family
ALLMARINE MAH
Pump Type
screw
Application
fuel
Allweiler Allweiler ALLMARINE MAH 5-6
Allweiler ALLMARINE MAH 5-6 unverified
Model Family
ALLMARINE MAH
Pump Type
screw
Flow Rate (m³/h)
5
Pressure (bar)
6
Application
fuel
Allweiler Allweiler ALLMARINE MAH 5-10
Allweiler ALLMARINE MAH 5-10 unverified
Model Family
ALLMARINE MAH
Pump Type
screw
Flow Rate (m³/h)
5
Pressure (bar)
10
Application
fuel
Allweiler Allweiler ALLMARINE MAH 5-16
Allweiler ALLMARINE MAH 5-16 unverified
Model Family
ALLMARINE MAH
Pump Type
screw
Flow Rate (m³/h)
5
Pressure (bar)
16
Application
fuel
Allweiler Allweiler ALLMARINE MAH 10-6
Allweiler ALLMARINE MAH 10-6 unverified
Model Family
ALLMARINE MAH
Pump Type
screw
Flow Rate (m³/h)
10
Pressure (bar)
6
Application
fuel
Allweiler Allweiler ALLMARINE MAH 10-10
Allweiler ALLMARINE MAH 10-10 unverified
Model Family
ALLMARINE MAH
Pump Type
screw
Flow Rate (m³/h)
10
Pressure (bar)
10
Application
fuel
Allweiler Allweiler ALLMARINE MAH 10-16
Allweiler ALLMARINE MAH 10-16 unverified
Model Family
ALLMARINE MAH
Pump Type
screw
Flow Rate (m³/h)
10
Pressure (bar)
16
Application
fuel
Allweiler Allweiler ALLMARINE MAH 25-6
Allweiler ALLMARINE MAH 25-6 unverified
Model Family
ALLMARINE MAH
Pump Type
screw
Flow Rate (m³/h)
25
Pressure (bar)
6
Application
fuel
Allweiler Allweiler ALLMARINE MAH 25-10
Allweiler ALLMARINE MAH 25-10 unverified
Model Family
ALLMARINE MAH
Pump Type
screw
Flow Rate (m³/h)
25
Pressure (bar)
10
Application
fuel
Allweiler Allweiler ALLMARINE MAH 25-16
Allweiler ALLMARINE MAH 25-16 unverified
Model Family
ALLMARINE MAH
Pump Type
screw
Flow Rate (m³/h)
25
Pressure (bar)
16
Application
fuel
Allweiler Allweiler ALLMARINE MAH 50-6
Allweiler ALLMARINE MAH 50-6 unverified
Model Family
ALLMARINE MAH
Pump Type
screw
Flow Rate (m³/h)
50
Pressure (bar)
6
Application
fuel
Allweiler Allweiler ALLMARINE MAH 50-10
Allweiler ALLMARINE MAH 50-10 unverified
Model Family
ALLMARINE MAH
Pump Type
screw
Flow Rate (m³/h)
50
Pressure (bar)
10
Application
fuel
Allweiler Allweiler ALLMARINE MAH 50-16
Allweiler ALLMARINE MAH 50-16 unverified
Model Family
ALLMARINE MAH
Pump Type
screw
Flow Rate (m³/h)
50
Pressure (bar)
16
Application
fuel
Allweiler Allweiler ALLMARINE MAH 80-6
Allweiler ALLMARINE MAH 80-6 unverified
Model Family
ALLMARINE MAH
Pump Type
screw
Flow Rate (m³/h)
80
Pressure (bar)
6
Application
fuel
Allweiler Allweiler ALLMARINE MAH 80-10
Allweiler ALLMARINE MAH 80-10 unverified
Model Family
ALLMARINE MAH
Pump Type
screw
Flow Rate (m³/h)
80
Pressure (bar)
10
Application
fuel
Allweiler Allweiler ALLMARINE MAH 80-16
Allweiler ALLMARINE MAH 80-16 unverified
Model Family
ALLMARINE MAH
Pump Type
screw
Flow Rate (m³/h)
80
Pressure (bar)
16
Application
fuel
Allweiler Allweiler ALLMARINE MAI Series
Allweiler ALLMARINE MAI Series unverified
Model Family
ALLMARINE MAI
Pump Type
screw
Application
fuel
Allweiler Allweiler ALLMARINE MAI 1-6
Allweiler ALLMARINE MAI 1-6 unverified
Model Family
ALLMARINE MAI
Pump Type
screw
Flow Rate (m³/h)
1
Pressure (bar)
6
Application
fuel
Allweiler Allweiler ALLMARINE MAI 1-10
Allweiler ALLMARINE MAI 1-10 unverified
Model Family
ALLMARINE MAI
Pump Type
screw
Flow Rate (m³/h)
1
Pressure (bar)
10
Application
fuel
Allweiler Allweiler ALLMARINE MAI 1-16
Allweiler ALLMARINE MAI 1-16 unverified
Model Family
ALLMARINE MAI
Pump Type
screw
Flow Rate (m³/h)
1
Pressure (bar)
16
Application
fuel
Allweiler Allweiler ALLMARINE MAI 3-6
Allweiler ALLMARINE MAI 3-6 unverified
Model Family
ALLMARINE MAI
Pump Type
screw
Flow Rate (m³/h)
3
Pressure (bar)
6
Application
fuel
Allweiler Allweiler ALLMARINE MAI 3-10
Allweiler ALLMARINE MAI 3-10 unverified
Model Family
ALLMARINE MAI
Pump Type
screw
Flow Rate (m³/h)
3
Pressure (bar)
10
Application
fuel
Allweiler Allweiler ALLMARINE MAI 3-16
Allweiler ALLMARINE MAI 3-16 unverified
Model Family
ALLMARINE MAI
Pump Type
screw
Flow Rate (m³/h)
3
Pressure (bar)
16
Application
fuel
Allweiler Allweiler ALLMARINE MAI 5-6
Allweiler ALLMARINE MAI 5-6 unverified
Model Family
ALLMARINE MAI
Pump Type
screw
Flow Rate (m³/h)
5
Pressure (bar)
6
Application
fuel
Allweiler Allweiler ALLMARINE MAI 5-10
Allweiler ALLMARINE MAI 5-10 unverified
Model Family
ALLMARINE MAI
Pump Type
screw
Flow Rate (m³/h)
5
Pressure (bar)
10
Application
fuel
Allweiler Allweiler ALLMARINE MAI 5-16
Allweiler ALLMARINE MAI 5-16 unverified
Model Family
ALLMARINE MAI
Pump Type
screw
Flow Rate (m³/h)
5
Pressure (bar)
16
Application
fuel
Allweiler Allweiler ALLMARINE MAI 10-6
Allweiler ALLMARINE MAI 10-6 unverified
Model Family
ALLMARINE MAI
Pump Type
screw
Flow Rate (m³/h)
10
Pressure (bar)
6
Application
fuel
Allweiler Allweiler ALLMARINE MAI 10-10
Allweiler ALLMARINE MAI 10-10 unverified
Model Family
ALLMARINE MAI
Pump Type
screw
Flow Rate (m³/h)
10
Pressure (bar)
10
Application
fuel
Allweiler Allweiler ALLMARINE MAI 10-16
Allweiler ALLMARINE MAI 10-16 unverified
Model Family
ALLMARINE MAI
Pump Type
screw
Flow Rate (m³/h)
10
Pressure (bar)
16
Application
fuel
Allweiler Allweiler ALLMARINE MAI 15-6
Allweiler ALLMARINE MAI 15-6 unverified
Model Family
ALLMARINE MAI
Pump Type
screw
Flow Rate (m³/h)
15
Pressure (bar)
6
Application
fuel
Allweiler Allweiler ALLMARINE MAI 15-10
Allweiler ALLMARINE MAI 15-10 unverified
Model Family
ALLMARINE MAI
Pump Type
screw
Flow Rate (m³/h)
15
Pressure (bar)
10
Application
fuel
Allweiler Allweiler ALLMARINE MAI 15-16
Allweiler ALLMARINE MAI 15-16 unverified
Model Family
ALLMARINE MAI
Pump Type
screw
Flow Rate (m³/h)
15
Pressure (bar)
16
Application
fuel
Allweiler Allweiler SNF Series
Allweiler SNF Series unverified
Model Family
SNF
Pump Type
screw
Application
fuel
Allweiler Allweiler SNF 1-6
Allweiler SNF 1-6 unverified
Model Family
SNF
Pump Type
screw
Flow Rate (m³/h)
1
Pressure (bar)
6
Application
fuel
Allweiler Allweiler SNF 1-10
Allweiler SNF 1-10 unverified
Model Family
SNF
Pump Type
screw
Flow Rate (m³/h)
1
Pressure (bar)
10
Application
fuel
Allweiler Allweiler SNF 1-16
Allweiler SNF 1-16 unverified
Model Family
SNF
Pump Type
screw
Flow Rate (m³/h)
1
Pressure (bar)
16
Application
fuel
Allweiler Allweiler SNF 3-6
Allweiler SNF 3-6 unverified
Model Family
SNF
Pump Type
screw
Flow Rate (m³/h)
3
Pressure (bar)
6
Application
fuel
Allweiler Allweiler SNF 3-10
Allweiler SNF 3-10 unverified
Model Family
SNF
Pump Type
screw
Flow Rate (m³/h)
3
Pressure (bar)
10
Application
fuel
Allweiler Allweiler SNF 3-16
Allweiler SNF 3-16 unverified
Model Family
SNF
Pump Type
screw
Flow Rate (m³/h)
3
Pressure (bar)
16
Application
fuel
Allweiler Allweiler SNF 5-6
Allweiler SNF 5-6 unverified
Model Family
SNF
Pump Type
screw
Flow Rate (m³/h)
5
Pressure (bar)
6
Application
fuel
Allweiler Allweiler SNF 5-10
Allweiler SNF 5-10 unverified
Model Family
SNF
Pump Type
screw
Flow Rate (m³/h)
5
Pressure (bar)
10
Application
fuel
Allweiler Allweiler SNF 5-16
Allweiler SNF 5-16 unverified
Model Family
SNF
Pump Type
screw
Flow Rate (m³/h)
5
Pressure (bar)
16
Application
fuel
Allweiler Allweiler SNF 10-6
Allweiler SNF 10-6 unverified
Model Family
SNF
Pump Type
screw
Flow Rate (m³/h)
10
Pressure (bar)
6
Application
fuel
Allweiler Allweiler SNF 10-10
Allweiler SNF 10-10 unverified
Model Family
SNF
Pump Type
screw
Flow Rate (m³/h)
10
Pressure (bar)
10
Application
fuel
Allweiler Allweiler SNF 10-16
Allweiler SNF 10-16 unverified
Model Family
SNF
Pump Type
screw
Flow Rate (m³/h)
10
Pressure (bar)
16
Application
fuel
Allweiler Allweiler SNF 25-6
Allweiler SNF 25-6 unverified
Model Family
SNF
Pump Type
screw
Flow Rate (m³/h)
25
Pressure (bar)
6
Application
fuel
Allweiler Allweiler SNF 25-10
Allweiler SNF 25-10 unverified
Model Family
SNF
Pump Type
screw
Flow Rate (m³/h)
25
Pressure (bar)
10
Application
fuel
Allweiler Allweiler SNF 25-16
Allweiler SNF 25-16 unverified
Model Family
SNF
Pump Type
screw
Flow Rate (m³/h)
25
Pressure (bar)
16
Application
fuel
Allweiler Allweiler SNF 50-6
Allweiler SNF 50-6 unverified
Model Family
SNF
Pump Type
screw
Flow Rate (m³/h)
50
Pressure (bar)
6
Application
fuel
Allweiler Allweiler SNF 50-10
Allweiler SNF 50-10 unverified
Model Family
SNF
Pump Type
screw
Flow Rate (m³/h)
50
Pressure (bar)
10
Application
fuel
Allweiler Allweiler SNF 50-16
Allweiler SNF 50-16 unverified
Model Family
SNF
Pump Type
screw
Flow Rate (m³/h)
50
Pressure (bar)
16
Application
fuel
Allweiler Allweiler SNF 80-6
Allweiler SNF 80-6 unverified
Model Family
SNF
Pump Type
screw
Flow Rate (m³/h)
80
Pressure (bar)
6
Application
fuel
Allweiler Allweiler SNF 80-10
Allweiler SNF 80-10 unverified
Model Family
SNF
Pump Type
screw
Flow Rate (m³/h)
80
Pressure (bar)
10
Application
fuel
Allweiler Allweiler SNF 80-16
Allweiler SNF 80-16 unverified
Model Family
SNF
Pump Type
screw
Flow Rate (m³/h)
80
Pressure (bar)
16
Application
fuel
Allweiler Allweiler SNH Series
Allweiler SNH Series unverified
Model Family
SNH
Pump Type
screw
Application
lube
Allweiler Allweiler SNH 1-6
Allweiler SNH 1-6 unverified
Model Family
SNH
Pump Type
screw
Flow Rate (m³/h)
1
Pressure (bar)
6
Application
lube
Allweiler Allweiler SNH 1-10
Allweiler SNH 1-10 unverified
Model Family
SNH
Pump Type
screw
Flow Rate (m³/h)
1
Pressure (bar)
10
Application
lube
Allweiler Allweiler SNH 1-16
Allweiler SNH 1-16 unverified
Model Family
SNH
Pump Type
screw
Flow Rate (m³/h)
1
Pressure (bar)
16
Application
lube
Allweiler Allweiler SNH 3-6
Allweiler SNH 3-6 unverified
Model Family
SNH
Pump Type
screw
Flow Rate (m³/h)
3
Pressure (bar)
6
Application
lube
Allweiler Allweiler SNH 3-10
Allweiler SNH 3-10 unverified
Model Family
SNH
Pump Type
screw
Flow Rate (m³/h)
3
Pressure (bar)
10
Application
lube
Allweiler Allweiler SNH 3-16
Allweiler SNH 3-16 unverified
Model Family
SNH
Pump Type
screw
Flow Rate (m³/h)
3
Pressure (bar)
16
Application
lube
Allweiler Allweiler SNH 5-6
Allweiler SNH 5-6 unverified
Model Family
SNH
Pump Type
screw
Flow Rate (m³/h)
5
Pressure (bar)
6
Application
lube
Allweiler Allweiler SNH 5-10
Allweiler SNH 5-10 unverified
Model Family
SNH
Pump Type
screw
Flow Rate (m³/h)
5
Pressure (bar)
10
Application
lube
Allweiler Allweiler SNH 5-16
Allweiler SNH 5-16 unverified
Model Family
SNH
Pump Type
screw
Flow Rate (m³/h)
5
Pressure (bar)
16
Application
lube
Allweiler Allweiler SNH 10-6
Allweiler SNH 10-6 unverified
Model Family
SNH
Pump Type
screw
Flow Rate (m³/h)
10
Pressure (bar)
6
Application
lube
Allweiler Allweiler SNH 10-10
Allweiler SNH 10-10 unverified
Model Family
SNH
Pump Type
screw
Flow Rate (m³/h)
10
Pressure (bar)
10
Application
lube
Allweiler Allweiler SNH 10-16
Allweiler SNH 10-16 unverified
Model Family
SNH
Pump Type
screw
Flow Rate (m³/h)
10
Pressure (bar)
16
Application
lube
Allweiler Allweiler SNH 25-6
Allweiler SNH 25-6 unverified
Model Family
SNH
Pump Type
screw
Flow Rate (m³/h)
25
Pressure (bar)
6
Application
lube
Allweiler Allweiler SNH 25-10
Allweiler SNH 25-10 unverified
Model Family
SNH
Pump Type
screw
Flow Rate (m³/h)
25
Pressure (bar)
10
Application
lube
Allweiler Allweiler SNH 25-16
Allweiler SNH 25-16 unverified
Model Family
SNH
Pump Type
screw
Flow Rate (m³/h)
25
Pressure (bar)
16
Application
lube
Allweiler Allweiler SPF Series
Allweiler SPF Series unverified
Model Family
SPF
Pump Type
screw
Application
fuel
Allweiler Allweiler SPF 5-6
Allweiler SPF 5-6 unverified
Model Family
SPF
Pump Type
screw
Flow Rate (m³/h)
5
Pressure (bar)
6
Application
fuel
Allweiler Allweiler SPF 5-10
Allweiler SPF 5-10 unverified
Model Family
SPF
Pump Type
screw
Flow Rate (m³/h)
5
Pressure (bar)
10
Application
fuel
Allweiler Allweiler SPF 5-16
Allweiler SPF 5-16 unverified
Model Family
SPF
Pump Type
screw
Flow Rate (m³/h)
5
Pressure (bar)
16
Application
fuel
Allweiler Allweiler SPF 10-6
Allweiler SPF 10-6 unverified
Model Family
SPF
Pump Type
screw
Flow Rate (m³/h)
10
Pressure (bar)
6
Application
fuel
Allweiler Allweiler SPF 10-10
Allweiler SPF 10-10 unverified
Model Family
SPF
Pump Type
screw
Flow Rate (m³/h)
10
Pressure (bar)
10
Application
fuel
Allweiler Allweiler SPF 10-16
Allweiler SPF 10-16 unverified
Model Family
SPF
Pump Type
screw
Flow Rate (m³/h)
10
Pressure (bar)
16
Application
fuel
Allweiler Allweiler SPF 25-6
Allweiler SPF 25-6 unverified
Model Family
SPF
Pump Type
screw
Flow Rate (m³/h)
25
Pressure (bar)
6
Application
fuel
Allweiler Allweiler SPF 25-10
Allweiler SPF 25-10 unverified
Model Family
SPF
Pump Type
screw
Flow Rate (m³/h)
25
Pressure (bar)
10
Application
fuel
Allweiler Allweiler SPF 25-16
Allweiler SPF 25-16 unverified
Model Family
SPF
Pump Type
screw
Flow Rate (m³/h)
25
Pressure (bar)
16
Application
fuel
Allweiler Allweiler SPF 50-6
Allweiler SPF 50-6 unverified
Model Family
SPF
Pump Type
screw
Flow Rate (m³/h)
50
Pressure (bar)
6
Application
fuel
Allweiler Allweiler SPF 50-10
Allweiler SPF 50-10 unverified
Model Family
SPF
Pump Type
screw
Flow Rate (m³/h)
50
Pressure (bar)
10
Application
fuel
Allweiler Allweiler SPF 50-16
Allweiler SPF 50-16 unverified
Model Family
SPF
Pump Type
screw
Flow Rate (m³/h)
50
Pressure (bar)
16
Application
fuel
Allweiler Allweiler SN Series
Allweiler SN Series unverified
Model Family
SN
Pump Type
screw
Application
fuel
Allweiler Allweiler SN 1-6
Allweiler SN 1-6 unverified
Model Family
SN
Pump Type
screw
Flow Rate (m³/h)
1
Pressure (bar)
6
Application
fuel
Allweiler Allweiler SN 1-10
Allweiler SN 1-10 unverified
Model Family
SN
Pump Type
screw
Flow Rate (m³/h)
1
Pressure (bar)
10
Application
fuel
Allweiler Allweiler SN 1-16
Allweiler SN 1-16 unverified
Model Family
SN
Pump Type
screw
Flow Rate (m³/h)
1
Pressure (bar)
16
Application
fuel
Allweiler Allweiler SN 3-6
Allweiler SN 3-6 unverified
Model Family
SN
Pump Type
screw
Flow Rate (m³/h)
3
Pressure (bar)
6
Application
fuel
Allweiler Allweiler SN 3-10
Allweiler SN 3-10 unverified
Model Family
SN
Pump Type
screw
Flow Rate (m³/h)
3
Pressure (bar)
10
Application
fuel
Allweiler Allweiler SN 3-16
Allweiler SN 3-16 unverified
Model Family
SN
Pump Type
screw
Flow Rate (m³/h)
3
Pressure (bar)
16
Application
fuel
Allweiler Allweiler SN 5-6
Allweiler SN 5-6 unverified
Model Family
SN
Pump Type
screw
Flow Rate (m³/h)
5
Pressure (bar)
6
Application
fuel
Allweiler Allweiler SN 5-10
Allweiler SN 5-10 unverified
Model Family
SN
Pump Type
screw
Flow Rate (m³/h)
5
Pressure (bar)
10
Application
fuel
Allweiler Allweiler SN 5-16
Allweiler SN 5-16 unverified
Model Family
SN
Pump Type
screw
Flow Rate (m³/h)
5
Pressure (bar)
16
Application
fuel
Allweiler Allweiler SN 10-6
Allweiler SN 10-6 unverified
Model Family
SN
Pump Type
screw
Flow Rate (m³/h)
10
Pressure (bar)
6
Application
fuel
Allweiler Allweiler SN 10-10
Allweiler SN 10-10 unverified
Model Family
SN
Pump Type
screw
Flow Rate (m³/h)
10
Pressure (bar)
10
Application
fuel
Allweiler Allweiler SN 10-16
Allweiler SN 10-16 unverified
Model Family
SN
Pump Type
screw
Flow Rate (m³/h)
10
Pressure (bar)
16
Application
fuel
Allweiler Allweiler SN 25-6
Allweiler SN 25-6 unverified
Model Family
SN
Pump Type
screw
Flow Rate (m³/h)
25
Pressure (bar)
6
Application
fuel
Allweiler Allweiler SN 25-10
Allweiler SN 25-10 unverified
Model Family
SN
Pump Type
screw
Flow Rate (m³/h)
25
Pressure (bar)
10
Application
fuel
Allweiler Allweiler SN 25-16
Allweiler SN 25-16 unverified
Model Family
SN
Pump Type
screw
Flow Rate (m³/h)
25
Pressure (bar)
16
Application
fuel
Allweiler Allweiler SN 50-6
Allweiler SN 50-6 unverified
Model Family
SN
Pump Type
screw
Flow Rate (m³/h)
50
Pressure (bar)
6
Application
fuel
Allweiler Allweiler SN 50-10
Allweiler SN 50-10 unverified
Model Family
SN
Pump Type
screw
Flow Rate (m³/h)
50
Pressure (bar)
10
Application
fuel
Allweiler Allweiler SN 50-16
Allweiler SN 50-16 unverified
Model Family
SN
Pump Type
screw
Flow Rate (m³/h)
50
Pressure (bar)
16
Application
fuel

Iron Pump

16
Iron Pump Iron Pump ONPR Series
Iron Pump ONPR Series unverified
Model Family
ONPR
Pump Type
screw
Application
fuel
Iron Pump Iron Pump ONPR 5/11
Iron Pump ONPR 5/11 unverified
Model Family
ONPR
Pump Type
screw
Flow Rate (m³/h)
5
Head (m)
11
Application
fuel
Iron Pump Iron Pump ONPR 5/17
Iron Pump ONPR 5/17 unverified
Model Family
ONPR
Pump Type
screw
Flow Rate (m³/h)
5
Head (m)
17
Application
fuel
Iron Pump Iron Pump ONPR 5/29
Iron Pump ONPR 5/29 unverified
Model Family
ONPR
Pump Type
screw
Flow Rate (m³/h)
5
Head (m)
29
Application
fuel
Iron Pump Iron Pump ONPR 10/13
Iron Pump ONPR 10/13 unverified
Model Family
ONPR
Pump Type
screw
Flow Rate (m³/h)
10
Head (m)
13
Application
fuel
Iron Pump Iron Pump ONPR 10/20
Iron Pump ONPR 10/20 unverified
Model Family
ONPR
Pump Type
screw
Flow Rate (m³/h)
10
Head (m)
20
Application
fuel
Iron Pump Iron Pump ONPR 10/33
Iron Pump ONPR 10/33 unverified
Model Family
ONPR
Pump Type
screw
Flow Rate (m³/h)
10
Head (m)
33
Application
fuel
Iron Pump Iron Pump ONPR 25/17
Iron Pump ONPR 25/17 unverified
Model Family
ONPR
Pump Type
screw
Flow Rate (m³/h)
25
Head (m)
17
Application
fuel
Iron Pump Iron Pump ONPR 25/27
Iron Pump ONPR 25/27 unverified
Model Family
ONPR
Pump Type
screw
Flow Rate (m³/h)
25
Head (m)
27
Application
fuel
Iron Pump Iron Pump ONPR 25/45
Iron Pump ONPR 25/45 unverified
Model Family
ONPR
Pump Type
screw
Flow Rate (m³/h)
25
Head (m)
45
Application
fuel
Iron Pump Iron Pump ONPR 50/25
Iron Pump ONPR 50/25 unverified
Model Family
ONPR
Pump Type
screw
Flow Rate (m³/h)
50
Head (m)
25
Application
fuel
Iron Pump Iron Pump ONPR 50/40
Iron Pump ONPR 50/40 unverified
Model Family
ONPR
Pump Type
screw
Flow Rate (m³/h)
50
Head (m)
40
Application
fuel
Iron Pump Iron Pump ONPR 50/65
Iron Pump ONPR 50/65 unverified
Model Family
ONPR
Pump Type
screw
Flow Rate (m³/h)
50
Head (m)
65
Application
fuel
Iron Pump Iron Pump ONPR 100/40
Iron Pump ONPR 100/40 unverified
Model Family
ONPR
Pump Type
screw
Flow Rate (m³/h)
100
Head (m)
40
Application
fuel
Iron Pump Iron Pump ONPR 100/65
Iron Pump ONPR 100/65 unverified
Model Family
ONPR
Pump Type
screw
Flow Rate (m³/h)
100
Head (m)
65
Application
fuel
Iron Pump Iron Pump ONPR 100/105
Iron Pump ONPR 100/105 unverified
Model Family
ONPR
Pump Type
screw
Flow Rate (m³/h)
100
Head (m)
105
Application
fuel

IMO Pumps

10
IMO Pumps IMO ACE 025N3 NVBP
IMO ACE 025N3 NVBP unverified
· 0.75 kW · lube oil
Pump Type
3-screw
Flow (m³/h)
2.5
Power (kW)
0.75
Medium
lube oil
IMO Pumps IMO ACE 038N3 NVBP
IMO ACE 038N3 NVBP unverified
· 1.1 kW · lube oil
Pump Type
3-screw
Flow (m³/h)
3.8
Power (kW)
1.1
Medium
lube oil
IMO Pumps IMO ACE 060K3 NVBP
IMO ACE 060K3 NVBP unverified
· 1.5 kW · lube oil
Pump Type
3-screw
Flow (m³/h)
6.0
Power (kW)
1.5
Medium
lube oil
IMO Pumps IMO ACE 110N3 NVBP
IMO ACE 110N3 NVBP unverified
· 3.0 kW · lube oil
Pump Type
3-screw
Flow (m³/h)
11.0
Power (kW)
3.0
Medium
lube oil
IMO Pumps IMO ACF 080K4 NVBP
IMO ACF 080K4 NVBP unverified
· 2.2 kW · fuel oil
Pump Type
3-screw
Flow (m³/h)
8.0
Power (kW)
2.2
Medium
fuel oil
IMO Pumps IMO ACF 100N4 NVBP
IMO ACF 100N4 NVBP unverified
· 3.0 kW · fuel oil
Pump Type
3-screw
Flow (m³/h)
10.0
Power (kW)
3.0
Medium
fuel oil
IMO Pumps IMO ACF 150N4 NVBP
IMO ACF 150N4 NVBP unverified
· 4.0 kW · fuel oil
Pump Type
3-screw
Flow (m³/h)
15.0
Power (kW)
4.0
Medium
fuel oil
IMO Pumps IMO ACG 060N7 NVBP
IMO ACG 060N7 NVBP unverified
· 1.5 kW · fuel oil HFO
Pump Type
3-screw
Flow (m³/h)
6.0
Power (kW)
1.5
Medium
fuel oil HFO
IMO Pumps IMO ACG 110N7 NVBP
IMO ACG 110N7 NVBP unverified
· 3.0 kW · fuel oil HFO
Pump Type
3-screw
Flow (m³/h)
11.0
Power (kW)
3.0
Medium
fuel oil HFO
IMO Pumps IMO ACG 200N7 NVBP
IMO ACG 200N7 NVBP unverified
· 5.5 kW · fuel oil HFO
Pump Type
3-screw
Flow (m³/h)
20.0
Power (kW)
5.5
Medium
fuel oil HFO

Alfa Laval

3
Alfa Laval Alfa Laval ALSP 30
Alfa Laval ALSP 30 unverified
· 1.1 kW · fuel oil/lube oil
Pump Type
3-screw
Flow (m³/h)
3
Power (kW)
1.1
Medium
fuel oil/lube oil
Alfa Laval Alfa Laval ALSP 60
Alfa Laval ALSP 60 unverified
· 2.2 kW · fuel oil/lube oil
Pump Type
3-screw
Flow (m³/h)
6
Power (kW)
2.2
Medium
fuel oil/lube oil
Alfa Laval Alfa Laval ALSP 120
Alfa Laval ALSP 120 unverified
· 4.0 kW · fuel oil/lube oil
Pump Type
3-screw
Flow (m³/h)
12
Power (kW)
4.0
Medium
fuel oil/lube oil

IMO

3
IMO AB ACG 052
ACG 052
50 m³/h @ 10 bar · 15.0 kW · Lube Oil · Triple-screw lubricating oil pump
Medium
Lube Oil
Power (kW)
15
Type
Triple Screw
Common Failures & Inspection Points
  • Screw wear from contaminated oil
  • Mechanical seal leakage
  • Relief valve sticking
  • Bearing failure from misalignment
Service: Check screw clearance at 8000 hrs. Replace mechanical seal every 16000 hrs. Monitor discharge pressure for wear indication.
Spare Parts: IMO AB: Ersatzteile per Hersteller-Ersatzteilliste. Mechanische Dichtungen und Laufräder an Bord vorhalten. Lead time: 2-6 Wochen je nach Hersteller.
Strengths
  • High volumetric efficiency with minimal flow ripple, ideal for steady lube‑oil supply
  • Compact footprint compared with multi‑stage centrifugal pumps
  • Integrated mechanical seal reduces external leakage points
  • Screw clearance can be inspected and adjusted at defined intervals (8000 hrs)
  • Relatively low power consumption for the delivered flow rate
Weaknesses
  • Screw wear accelerates if oil is contaminated; requires strict filtration
  • Mechanical seal life limited to ~16 000 hrs, increasing scheduled maintenance
  • Relief valve may stick under high‑temperature operation, demanding frequent checks
  • Bearing failure risk if shaft alignment is not maintained during installation
  • Limited flow capacity compared with larger centrifugal alternatives
Typical Vessels: TankerBulk carrierContainer shipGeneral cargo vesselOffshore supply vessel
Decision Guide: Choose if: you need a compact, low‑pulsation lube‑oil pump for medium‑size vessels and can maintain strict oil cleanliness and regular seal inspections. Avoid if: the installation environment has high contamination risk, limited maintenance windows, or requires very high flow rates beyond screw‑pump capability.
Use Cases: Commonly installed in main engine rooms to supply lubricating oil to bearings, gearboxes and auxiliary machinery where a steady, low‑vibration flow is critical. Often paired with oil filtration units and pressure monitoring systems to detect wear early.
IMO AB ACE 032
ACE 032
32 m³/h @ 12 bar · 11.0 kW · Fuel Oil · Triple screw fuel oil pump
Medium
Fuel Oil
Power (kW)
11
Type
Triple Screw
Common Failures & Inspection Points
  • Screw scoring from fuel contamination
  • Seal leakage at high viscosity
  • Suction strainer clogging
Service: Pre-heat HFO to reduce viscosity. Clean suction strainer regularly. Relief valve set at 14 bar.
Spare Parts: IMO AB: Ersatzteile per Hersteller-Ersatzteilliste. Mechanische Dichtungen und Laufräder an Bord vorhalten. Lead time: 2-6 Wochen je nach Hersteller.
Strengths
  • Low pulsation flow suitable for viscous HFO
  • Compact 11 kW motor size fits small to medium vessels
  • Self‑priming capability reduces start‑up time
  • Gentle handling minimizes shear damage to lubricating oils
Weaknesses
  • Screw scoring if fuel contains contaminants or water
  • Seal leakage can occur at higher oil viscosities
  • Requires pre‑heating of HFO and frequent strainer cleaning
  • Relief valve setpoint (14 bar) may be high for some low‑pressure systems
Typical Vessels: Product tankerBulk carrier with fuel oil transfer needsOffshore supply vesselGeneral cargo ship with diesel generators
Decision Guide: Choose if you need a compact, low‑pulsation pump for HFO on vessels where pre‑heating and regular maintenance are acceptable. Avoid if fuel quality control is poor, or if the installation cannot accommodate a 14 bar relief setting.
Use Cases: Bunkering operations, intra‑tank fuel oil transfer, circulation of heavy fuel to main engines and auxiliary generators on tankers and bulk carriers.
IMO AB ACE 038
ACE 038
38 m³/h @ 8 bar · 7.5 kW · Fuel Oil · Triple screw fuel oil pump
Medium
Fuel Oil
Power (kW)
7.5
Type
Triple Screw
Common Failures & Inspection Points
  • Screw wear
  • Mechanical seal failure
  • Coupling misalignment
Service: Supply pump to purifier — maintain constant pressure. Check coupling alignment every 4000 hrs.
Spare Parts: IMO AB: Ersatzteile per Hersteller-Ersatzteilliste. Mechanische Dichtungen und Laufräder an Bord vorhalten. Lead time: 2-6 Wochen je nach Hersteller.
Strengths
  • Low pulsation flow ideal for fuel oil purification
  • Self‑priming and tolerant of viscous fuels
  • Compact footprint suitable for confined engine rooms
  • Moderate power (7.5 kW) gives good efficiency at low to medium flow rates
  • Simple mechanical design eases routine inspection
Weaknesses
  • Screw wear requires periodic monitoring and possible re‑grinding
  • Mechanical seal failures are a known failure mode
  • Coupling misalignment can develop if not checked every 4 000 h
  • Limited maximum flow compared with larger centrifugal pumps
  • Replacement parts may be specific to IMO AB, affecting spares availability
Typical Vessels: Product tankerOil‑fuel carrierOffshore supply vesselCruise shipContainer ship (auxiliary fuel system)
Decision Guide: Choose if you need a reliable, low‑pulsation fuel oil pump in a space‑constrained installation and can commit to regular coupling alignment checks. Avoid if the vessel requires high flow rates, very high overall efficiency, or if spare parts logistics for IMO AB are problematic.
Use Cases: Supplying fuel oil to shipboard purifiers for diesel generators, feeding low‑pressure fuel lines between tanks, supporting bunkering operations on tankers and offshore vessels where steady pressure is critical.

Kracht

2
Kracht KF-80
KF-80
80 L/min @ 16 bar · 5.5 kW · Fuel Oil · Gear pump
Medium
Fuel Oil
Power (kW)
5.5
Type
Gear Pump
Common Failures & Inspection Points
  • Gear tooth wear
  • Shaft seal leakage
  • Cavitation at high viscosity
  • Relief valve malfunction
Service: Replace shaft seals every 8000 hrs. Monitor flow rate for wear indication. Ensure adequate NPSH.
Spare Parts: Kracht: Ersatzteile per Hersteller-Ersatzteilliste. Mechanische Dichtungen und Laufräder an Bord vorhalten. Lead time: 2-6 Wochen je nach Hersteller.
Strengths
  • Compact size and low power consumption (5.5 kW) suitable for space‑constrained installations
  • Self‑priming capability eliminates the need for external priming equipment
  • Robust Kracht brand reputation for marine service reliability
  • Straightforward maintenance – shaft seals are replaced on a defined 8,000 hr interval
  • Adequate flow rates for auxiliary and main fuel oil supply on medium‑sized vessels
Weaknesses
  • Gear tooth wear can lead to reduced efficiency and requires periodic inspection
  • Cavitation risk when pumping high‑viscosity fuels or at low NPSH conditions
  • Relief valve may malfunction if not regularly tested, potentially causing over‑pressure
  • Limited maximum flow compared with larger centrifugal fuel pumps
  • Sensitive to improper seal installation – leakage can develop before the 8,000 hr interval
Typical Vessels: Product tankerChemical tankerOffshore supply vesselMedium‑size container shipCruise ship auxiliary systems
Decision Guide: Choose if you need a reliable, low‑power fuel oil pump with self‑priming ability for medium‑viscosity fuels and have regular maintenance intervals available. Avoid if the installation requires very high flow rates, will operate with high‑viscosity or contaminated fuel, or cannot guarantee periodic seal and relief‑valve checks.
Use Cases: Primarily used for bunker fuel transfer from tank to engine room, supplying auxiliary generators, and feeding lubricating oil systems on vessels where space and power budgets are limited.
Kracht KF-150
KF-150
150 L/min @ 10 bar · 7.5 kW · Lube Oil · gear lube oil pump
Medium
Lube Oil
Power (kW)
7.5
Type
Gear Pump
Common Failures & Inspection Points
  • Gear wear from contaminated oil
  • Bearing failure
  • Shaft seal leakage
Service: Use filtered oil. Shaft seal replacement every 12000 hrs. Check gear backlash at overhaul.
Spare Parts: Kracht: Ersatzteile per Hersteller-Ersatzteilliste. Mechanische Dichtungen und Laufräder an Bord vorhalten. Lead time: 2-6 Wochen je nach Hersteller.
Strengths
  • Low power consumption (7.5 kW) suitable for auxiliary service
  • Compact design fits tight engine room spaces
  • Straightforward overhaul procedures – gear backlash check and seal replacement intervals are well defined
  • Kracht reputation for robust construction in marine environments
Weaknesses
  • Gear wear accelerates if oil is not properly filtered
  • Bearing failures reported when operating beyond design temperature limits
  • Shaft seal leakage requires replacement every ~12 000 h
  • Limited pressure capability compared with larger screw‑type pumps
Typical Vessels: TankerContainer shipBulk carrierOffshore supply vesselGeneral cargo vessel
Decision Guide: Choose if: you need a small, low‑power lube oil pump for main engine or gearbox lubrication and can maintain strict oil filtration and seal replacement schedules. Avoid if: high pressure or contamination‑tolerant pumping is required, or if longer seal intervals are critical.
Use Cases: Commonly installed on marine diesel engines to circulate lubricating oil through bearings, gearboxes and auxiliary machinery; also used in secondary systems such as hydraulic oil circulation where modest flow rates are sufficient.