OceanSphereFree accountLog inDEENPL
OceanSphereENGINES
Library› HVAC› Water Treatment› Chlorination System
Water Treatment

Chlorination System

A chlorination system doses hypochlorite, generated on board or supplied in tanks, into the potable water line to keep bacterial counts down between the point of production and the cabin tap, and it is the most common method used where UV alone cannot reach stored water.

11models
RWO/Veolia
Knowledge

What to check on a Chlorination System.

11 models from RWO/Veolia in Chlorination System. Below: the full model list.

What Sets Chlorination Apart

Chlorination protects water after it leaves the point of treatment, which is what separates it from UV sterilizers or reverse osmosis membranes that only act at a single point in the system. A residual dose of chlorine keeps working as water sits in tanks and travels through long, sometimes stagnant pipe runs where regrowth of Legionella and coliform bacteria is the real risk. Systems either generate sodium hypochlorite on board by electrolysis of a brine solution, or dose a stored hypochlorite solution from a day tank. Electrolytic generation avoids storing and handling concentrated chemical but depends on a working brine and power supply; dosing from stored solution is simpler but ties the ship to a chemical resupply chain.

Potable water chlorination flow
Flow diagram of a potable water chlorination system showing a dosing pump injecting sodium hypochlorite from its storage tank into the water main, a contact loop giving retention time, a sample cock, and a chlorine analyzer before the water reaches the distribution system.
Read the full guide

Main Components

Electrolytic Cell or Chemical Dosing Pump

The dosing pump is a positive-displacement or diaphragm pump metering hypochlorite solution in proportion to flow; the electrolytic cell produces hypochlorite in situ from a saturated brine feed and a DC power supply.

Brine Tank and Salt Saturator

Where fitted, a saturator dissolves solid salt to feed the electrolytic cell at a consistent concentration.

Residual Chlorine Analyzer

An in-line sensor that measures free or total residual chlorine and feeds back to the dosing controller to hold the setpoint automatically.

Contact Tank

A holding volume sized to give the dosed water enough contact time before it reaches the first outlet, so disinfection is complete rather than partial.

Day Tank and Injection Point

The storage vessel for ready-to-dose hypochlorite solution and the injection fitting into the potable water main, positioned upstream of the pressure set and storage tanks.

Selection and Sizing

  • Daily potable water production or bunkered volume, which sets the required dosing pump capacity.
  • Target residual, generally kept in a narrow band that is enough to suppress regrowth without giving the water a strong taste.
  • Contact time available before the first draw-off point, which limits how low the dose can be set.
  • Whether the ship already carries a brine or salt supply chain, which favors electrolytic generation over stored chemical.

Regulations and Class

Potable water quality on board is addressed through flag state and port state health regulations rather than a single IMO instrument, and many operators apply WHO drinking water guideline values as the practical benchmark for residual chlorine and microbiological limits. Class societies typically require the potable water system, including the dosing arrangement, to be part of the vessel's health and hygiene documentation reviewed at survey, and passenger vessels usually carry stricter internal monitoring frequencies driven by public health inspection regimes.

Typical Faults

FaultCauseConsequence
Residual drops to zeroEmpty day tank, failed dosing pump, or fouled electrolytic cellLoss of protection, risk of bacterial regrowth in storage tanks
Chlorine taste complaintsDosing controller set too high or analyzer drifted out of calibrationCrew reduces or bypasses dosing informally, defeating the system
Scale buildup on electrolytic cell platesHard brine feed or infrequent acid cleaning cycleFalling hypochlorite output despite normal power draw
Analyzer foulingBiofilm or scale on the sensor electrodeFalse high or low readings, dosing controller chases the wrong setpoint

What to Look for in a Supplier

  • A dosing controller with logged residual chlorine trend data, since spot checks alone will not catch an intermittent failure.
  • Clear guidance on cell cleaning intervals if electrolytic generation is chosen, matched to the ship's actual brine quality.
  • Materials in contact with hypochlorite rated for the chemical, not a generic plastic that degrades under chlorine exposure.
  • Compatibility of the injection point and contact tank with the existing potable water layout, avoiding a redesign of the whole system.

Never judge a chlorination system by the dosing pump running; judge it by the residual reading at the farthest tap on the ship, that is where a failing system shows up first.

Models

Models in this type.

The best-documented model of each manufacturer first, then the next — 11 of 11 models in Chlorination System. Every row links to full specifications, documents and service notes.

Showing only RWO/Veolia. Show all manufacturers
11 models
By manufacturer

Manufacturers.

All 10 manufacturers with models of Chlorination System. Names with a manufacturer page open it; the others open a search across the full library.

All manufacturers
Related types

Also in Water Treatment.

The other equipment types in this category.

Hot Water CalorifierMarine ChlorinatorMineral Dosing SystemReverse Osmosis UnitSanitary Flush Control Set (WC)Sewage Treatment PlantUV SterilizerUV Water SterilizerVacuum Toilet SystemWater SoftenerWatermaker (Desalinator)
Would you like to know more?

One request. A person reads it and replies by e-mail.

Tell us the manufacturer, the model and what you need — a part, a service call, a second opinion. A person reads every request and replies by e-mail.

No details at hand? A photo of the rating plate or the part is enough — simply attach it to the request.

Frequently asked

Three things people ask first.

Is Chlorination System data free?

Yes. Every model page, every guide and every datasheet for this type is readable without an account. An account adds saved searches and requests, nothing is taken away.

My model is missing — what now?

Send us the nameplate. We identify it by hand, add it to the library, and if you need a part or a service, the request is already on our desk.

Can you source a Chlorination System part?

Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.