Skip to content
OceanSphereDEENPL
OceanSphereENGINES
Library› Electrical› Power Generation› Generator Set
Power Generation

Generator Set

A generator set pairs a diesel engine with an AC alternator on one common bed to make the ship's electrical power independently of propulsion, unlike a shaft generator that only produces power while the main engine is turning.

69models
MTU
Knowledge

What to check on a Generator Set.

69 models from MTU in Generator Set. Below: the full model list.

What Makes a Generator Set Different

A generator set, or genset, is a diesel engine and a synchronous alternator built on one common bed, driven at a fixed speed and delivering three-phase AC power at the ship's supply voltage and frequency. It is self-contained and can be started, loaded and stopped independently of the propulsion plant. That sets it apart from a shaft generator, coupled to the main engine's reduction gear and only able to hold frequency while the vessel is under way at sufficient speed, and from the emergency generator, a dedicated, separately located unit sized only to cover safety loads after a blackout.

Generator set arrangement
Side view of a generator set showing the diesel engine and alternator joined by a flexible coupling on one common bedplate, with the terminal box, exhaust outlet, cooling water connections and anti-vibration mounts.

Legend

  1. exhaust outlet
  2. diesel engine
  3. alternator
  4. terminal box
  5. flexible coupling
  6. cooling water
  7. common bedplate
  8. anti-vibration mounts

Most ships carry two to four gensets so load can be shared, one unit can be taken out for overhaul without losing redundancy, and sets can be run in parallel when peak load from cargo pumps, bow thruster or mooring winches exceeds what one machine can carry alone.

Main Components

Prime mover

A medium-speed, four-stroke diesel engine, typically running 720-1000 rpm on a 50 Hz ship or 900-1200 rpm on 60 Hz, with rated speed chosen to divide evenly into the required frequency by the alternator's pole count.

Read the full guide

Alternator

A brushless synchronous alternator with an automatic voltage regulator (AVR) that holds output voltage constant as load changes and supplies the excitation needed for parallel operation.

Governor

Controls fuel rack position to hold speed, and therefore frequency, within class limits under sudden load changes. Most newer installations use electronic governors integrated with the power management system rather than the older mechanical-hydraulic type.

Control and protection panel

Houses synchronizing equipment, protection relays for reverse power, overcurrent, earth fault and over/under frequency, and the interface to the ship's power management system (PMS).

Cooling, starting and exhaust

Jacket water and charge air cooling circuits, a compressed-air or electric starting system, and an exhaust line with silencer and, on newer tonnage, selective catalytic reduction (SCR) or exhaust gas recirculation (EGR) for NOx control.

Selection and Sizing

  • Rated output in kW at a stated power factor, usually 0.8, since alternators are rated in kVA
  • Voltage and frequency: 440 V / 60 Hz is common on many trading vessels, 690 V on ships with large electric propulsion or thruster loads
  • Number of sets versus redundancy required, balancing capital cost against the ability to lose one set and still cover essential load
  • Fuel flexibility: MDO/MGO only, dual-fuel capability, or heavy fuel oil capable with the necessary treatment plant

Regulations and Class

NOx emissions fall under MARPOL Annex VI and are certified per engine through an EIAPP certificate confirming compliance with the applicable Tier limit for the ship's construction date and operating area. Classification societies require that gensets can be paralleled safely, that load-sharing and load-shedding logic is proven, and that the vessel can recover from a full blackout within a defined time. Periodic survey covers governor response, protection relay testing and insulation resistance of the windings.

Typical Faults

FaultCauseConsequence
Wet stackingProlonged running at low load, common when oversized sets cover light harbour loadUnburnt fuel and carbon foul the turbocharger, exhaust and injectors
Failed synchronizing or reverse power tripGovernor droop mismatch or AVR fault between paralleled setsSet trips offline, remaining sets can overload, risk of blackout
High jacket water temperature alarmCooler fouling or seawater pump failureAutomatic load reduction or shutdown to prevent engine damage
Falling insulation resistanceMoisture or oil vapour ingress into alternator windingsEarth fault trip, risk of winding failure if not dried out and corrected

What to Look for in a Supplier

  • Engine and alternator already offered as a matched, type-tested package rather than assembled from unrelated components
  • Valid EIAPP certification for the NOx tier the ship needs, with documentation the flag state will accept
  • A service and spares network reaching the vessel's actual trading area, not just the country of manufacture
  • Published noise and vibration data compatible with the engine room's resilient mounting arrangement
  • A control system that integrates cleanly with the vessel's existing power management system

A genset that spends most of its life lightly loaded in port will foul faster than one working near its rated output; rotating duty between sets and avoiding permanent light-load running on one machine saves far more maintenance than any oil additive.

Models

Models in this type.

The best-documented model of each manufacturer first, then the next — 69 of 69 models in Generator Set. Every row links to full specifications, documents and service notes.

Showing only MTU. Show all manufacturers
MTU0113 DS MTU12470 V MTU12470 V-3 Phase MTU12V 1600 R70LP MTU12V 1600 R70P MTU12V 1600 R80LP MTU12V 1600 R80P MTU12V 4000 L64/16V Series 4000 L64 MTU12V4000 DS1250/12V4000 DS1500 MTU12V4000 DS1650 MTU12V4000 DS1750 MTU12V4000 DS2000 MTU13200 V MTU13200 V-3 Phase MTU13800 V MTU13800 V-3 Phase MTU16V4000 DS MTU20V 4000 DS MTU20V 4000 GS MTU20V4000 DS2750 MTU20V4000 GS/16V4000 DS MTU20V4000G14F F MTU49.3 optional LSA 46.3 MTU956TB33 12V/16V MTUA001070/.. MTUGas Engine - Engine-Generator Set MTULSA 49.1 MTULSAH 44.3 MTUMTU 12V4000 DS1250 MTUMTU 12V4000 DS1500 MTUMTU 16V4000 DS2000 MTUMTU 20V4000 DS 2750 MTUMTU 20V4000 DS2500 MTUMTU 20V4000 DS2800 MTUMTU 20V4000 DS3000 MTUMTU 20V4000 DS3250 MTUS4000 MTUgas engine – Engine-generator set MTUmtu 12V4000 GS MTUmtu 1600 DS/mtu 12V1600 DS550 MTUmtu 16V4000 GS MTUmtu 2000 DS/mtu 1600 DS MTUmtu 20V4000 GS MTUmtu 4R0060 DS30 MTUmtu 4R0113 DS100 MTUmtu 4R0113 DS125 MTUmtu 4R0113 DS40 MTUmtu 4R0113 DS50 MTUmtu 4R0113 DS60 MTUmtu 4R0113 DS80 MTUmtu 6R0113 DS150 MTUmtu 6R0113 DS180 MTUmtu 8V4000 GS MTU1151 - 1523 mtu / Rolls-Royce Power Systems12V 4000 M33S/16V 4000 M33S mtu / Rolls-Royce Power Systems12V 4000 P63 MTU1537 - 2030 mtu / Rolls-Royce Power Systems16V 4000 P63 MTU1948 - 2535 mtu / Rolls-Royce Power Systems20V 4000 P63 MTU762 - 1013 mtu / Rolls-Royce Power SystemsMG10V2000M72 mtu / Rolls-Royce Power SystemsMG12V2000M72 mtu / Rolls-Royce Power SystemsMG12V4000M23S mtu / Rolls-Royce Power SystemsMG12V4000M33S mtu / Rolls-Royce Power SystemsMG8V2000M72 mtu / Rolls-Royce Power SystemsMG8V4000M23S mtu / Rolls-Royce Power SystemsMG8V4000M33S MTUmtu 0060
Would you like to know more?

One request. A person reads it and replies by e-mail.

Tell us the manufacturer, the model and what you need — a part, a service call, a second opinion. A person reads every request and replies by e-mail.

No details at hand? A photo of the rating plate or the part is enough — simply attach it to the request.

Frequently asked

Three things people ask first.

Is Generator Set data free?

Yes. Every model page, every guide and every datasheet for this type is readable without an account. An account adds saved searches and requests, nothing is taken away.

My model is missing — what now?

Send us the nameplate. We identify it by hand, add it to the library, and if you need a part or a service, the request is already on our desk.

Can you source a Generator Set part?

Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.