Gas Detection (Cargo Area)
Fixed gas detection in the cargo area has to catch a flammable hydrocarbon leak and a toxic or oxygen-depleting one at the same time, which is why cargo area detector heads nearly always pair an LEL sensor with a separate oxygen or toxic gas cell.
What to check on a Gas Detection (Cargo Area).
3 models from Dräger in Gas Detection (Cargo Area). Below: the full model list.
What cargo area gas detection has to catch
A gas carrier's cargo area presents two separate hazards at once: a flammable hydrocarbon leak that can reach its lower explosive limit (LEL), and, depending on the cargo, a toxic or asphyxiating atmosphere from the gas itself or from an inert blanket displacing oxygen. Fixed detection in the cargo area is designed around both, typically pairing a catalytic bead or infrared sensor for percentage-LEL readings with a separate electrochemical cell for oxygen or the specific toxic gas the cargo grade requires, such as ammonia or hydrogen sulphide on the relevant cargoes.
Legend
- weatherproof enclosure
- sample inlet
- LEL sensor (catalytic)
- toxic / O2 sensor
- gas detection panel
- common alarm
- cable
- junction box
- LEL
- TOX
Main components
Detector heads
Distributed across the deck, in the cargo compressor room, cargo pump rooms, void spaces around cargo tanks, and at points of high leak probability such as manifold connections and vent risers. Placement follows the ship's hazardous area drawing, not a uniform grid.
Sample-draw versus diffusion (point) detectors
Enclosed or hard-to-access spaces often use sample-draw systems, where a pump pulls air through tubing to a central analyser cycling between multiple sample points. Open deck areas more often use diffusion-type point detectors that respond directly to gas reaching the sensor head, giving a faster response where continuous airflow can be relied on.
Read the full guide
Control panel and cause-and-effect matrix
Ties every detector to a defined action: first alarm at a low percentage of LEL, second alarm and automatic trip of cargo operations, compressor shutdown, or ventilation fan stop at a higher threshold. This cause-and-effect matrix is specific to the ship and is what the officer of the watch and cargo control room actually rely on during operations, more than the raw sensor reading itself.
Selection considerations
| Parameter | Typical figure |
|---|---|
| First alarm setpoint | ~20-30% LEL |
| Second alarm / trip setpoint | ~50-60% LEL |
| Oxygen deficiency alarm | ~19.5% O2 |
| Response time, diffusion type | Seconds to under a minute |
Regulations and class
The IGC Code sets out required fixed gas detection coverage for cargo areas on gas carriers, tied to the specific cargoes the ship is certified to carry, and links detector alarms to prescribed automatic actions such as ventilation shutdown or cargo operation trips. Class surveys verify detector calibration records, response to test gas at each head, and that the cause-and-effect matrix in the control system matches the ship's approved documentation, not just that the panel powers up and shows normal.
Typical faults
| Fault | Consequence |
|---|---|
| Sensor drift between calibrations | False alarms, or worse, a real leak read as below alarm threshold |
| Sample line blocked or crushed | Sample-draw detector reports a fault or a falsely clean reading from that point |
| Detector head sited outside the actual leak path after a piping modification | Coverage gap that the original hazardous area study no longer reflects |
| Calibration gas cylinder expired or wrong gas mix used | Test result looks fine but does not verify the sensor against the real target gas |
What to look for in a supplier
- Sensor types matched to the specific cargo grades on the ship's certificate of fitness, not a generic hydrocarbon-only package
- Calibration and test gas support available at the ports the ship trades to
- Cause-and-effect logic that can be reviewed and updated if the ship's cargo certificate or piping changes
- Detector heads rated for the actual hazardous area zone at each mounting location, not a single certification across the board
Check the calibration date and test gas certificate on every head during handover, not just the panel's self-diagnostic; a detector can show green on the panel and still be reading a stale calibration from months earlier.
Models in this type.
The best-documented model of each manufacturer first, then the next — 3 of 3 models in Gas Detection (Cargo Area). Every row links to full specifications, documents and service notes.
Manufacturers.
All 4 manufacturers with models of Gas Detection (Cargo Area). Names with a manufacturer page open it; the others open a search across the full library.
All manufacturers in the libraryAlso in Gas Carrier Cargo Systems.
The other equipment types in this category.
Write to us about your machine — the answer comes by e-mail.
Name the make and the model and what the job is: a spare, a service call, a second opinion on a data sheet. We answer by e-mail.
No details at hand? A photo of the rating plate or the part is enough — simply attach it to the request.
Questions that come up with this equipment.
Is Gas Detection (Cargo Area) data free?
Yes. Every model page, every guide and every datasheet for this type is readable without an account. An account adds saved searches and requests, nothing is taken away.
My model is missing — what now?
Send us the nameplate. We identify it by hand, add it to the library, and if you need a part or a service, the request is already on our desk.
Can you source a Gas Detection (Cargo Area) part?
Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.