A portable foam extinguisher works by starving a Class B fire of oxygen and cooling the fuel surface, which is why it is standard beside fuel manifolds and in engine rooms while CO2 units cover enclosed electrical spaces instead.

NAFFCO Marine
Wiedza

Co sprawdzić w Foam Extinguisher.

24 modeli od NAFFCO Marine w Foam Extinguisher. Poniżej pełna lista modeli.

What Makes This Type Different

A portable foam extinguisher discharges an aqueous film-forming foam (AFFF) concentrate mixed with water and expelled by a propellant gas. The foam blanket spreads across the surface of a burning liquid, cutting off oxygen and cooling the fuel below its flash point, which makes it effective on Class B fires — fuel, oil, paint — that a water jet would simply spread. It differs from CO2 units, which smother by displacing oxygen and suit enclosed electrical or engine spaces, and from dry powder units, which knock down the flame quickly but leave no lasting vapour seal and allow re-ignition.

Portable foam extinguisher section
Section through a cartridge-operated portable foam extinguisher showing the body filled with foam premix solution, the internal gas cartridge that pressurises it when the lever punctures it, the siphon tube, and the discharge hose leading to the nozzle.

Legend

  1. operating lever
  2. discharge valve head
  3. siphon tube
  4. discharge hose & nozzle
  5. foam premix solution
  6. gas cartridge

Main Components

Cylinder and Charge

Steel cylinder holding the premixed foam concentrate and water solution, pressurised either by a stored-pressure gauge or by a separate CO2 cartridge that the operator pierces to charge the unit at the point of use.

Discharge Valve and Hose

Squeeze-grip or lever valve, short hose and a foam-making nozzle that aerates the solution as it leaves the nozzle — a plain jet nozzle without aeration wastes most of the extinguishing effect.

Przeczytaj cały przewodnik

Pressure Gauge

Fitted to stored-pressure types only; a needle in the red band means the unit will not deliver a full, sustained discharge even though it looks intact.

Mounting Bracket

Quick-release bracket at a fixed, marked location per the fire control plan — an extinguisher stowed anywhere else is a finding on both internal rounds and port state inspections.

Selection and Sizing

  • Capacity: typically 9 litres for portable foam units on merchant ships, chosen to match the fire control plan's coverage for a given space, not swapped in ad hoc.
  • Discharge type: stored-pressure for immediate readiness versus gas-cartridge for long-term storage in less accessible locations.
  • Location: near fuel oil manifolds, purifier rooms and paint lockers, where Class B risk is highest and CO2 would be the wrong choice for a manned space.
  • Foam type: AFFF versus fluorine-free formulations — several flag states and port authorities now restrict PFAS-containing AFFF, which affects what can be legally recharged.

Regulations and Class

SOLAS Ch. II-2 and the Fire Safety Systems (FSS) Code set the minimum number, type and placement of portable extinguishers per space. Each unit carries a maker's test certificate and a service due date; class and flag surveys check the annual visual inspection tag and the hydrostatic test interval, generally every five years for the cylinder, alongside the vessel's own fire control plan. A missing service tag is treated the same as a missing extinguisher during survey.

Typical Faults

FaultConsequence
Pressure gauge in red zone, unit not rechargedExtinguisher discharges weakly or not at all when needed
Foam concentrate past its shelf lifeReduced foam quality, poor blanket formation on the fuel surface
Safety pin missing or seal broken without recordUnit may have been partially discharged and not reported
Corroded cylinder baseRisk of cylinder failure under internal pressure during use
Nozzle blocked or aerating screen missingSolution leaves as a jet instead of foam, poor fire knockdown

What to Look for in a Supplier

  • Servicing station approved by the extinguisher's original manufacturer and by the vessel's flag or class, with traceable service records.
  • Fluorine-free foam concentrate available where AFFF is being phased out under port or flag restrictions.
  • Cylinders that meet the hydrostatic test interval documented on the body stamp, not just a fresh paint job.
  • Same foam type across the fleet where practical, to avoid mixing concentrates that behave differently in cold weather.

Check the pressure gauge and the tamper seal on every fire round — a foam extinguisher that looks untouched can still have a spent charge if the gauge was never read.

Według producenta

Producenci.

Wszyscy producenci (13) z modelami Foam Extinguisher. Nazwy ze stroną producenta otwierają ją; pozostałe otwierają wyszukiwanie w całej bibliotece.

Wszyscy producenci w bibliotece
Podobne typy

Także w kategorii Gaśnice przenośne.

Pozostałe typy urządzeń w tej kategorii.

Gaśnica CO2DCP ExtinguisherDry Powder ExtinguisherGaśnica mgłowaGaśnica przewoźna
Więcej, niż pokazuje karta katalogowa

Napisz do nas o swojej maszynie — odpowiedź przyjdzie e-mailem.

Podaj producenta i model oraz czego dotyczy sprawa: część, serwis, druga opinia o karcie katalogowej. Odpowiadamy e-mailem.

Brak danych? Wystarczy zdjęcie tabliczki znamionowej lub części — dołącz je do zapytania.

Często pytane

Pytania, które pojawiają się przy tym sprzęcie.

Czy dane dla typu „Foam Extinguisher” są bezpłatne?

Tak. Każda strona modelu, każdy przewodnik i każda karta katalogowa tego typu są dostępne bez konta. Konto dodaje zapisane wyszukiwania i zapytania, niczego nie odbiera.

Brakuje mojego modelu — co teraz?

Prześlij tabliczkę znamionową. Rozpoznajemy ją ręcznie, dodajemy do biblioteki, a jeśli potrzebujesz części lub serwisu, zapytanie już u nas leży.

Czy możecie zdobyć część do Foam Extinguisher?

Tak. Podaj producenta, model i czego potrzebujesz — każde zapytanie czyta człowiek i odpowiada e-mailem.