Split AC Unit
A split AC unit pairs an indoor evaporator with a separate outdoor condensing unit joined by refrigerant piping, conditioning one space such as the bridge or a cabin on its own circuit, in contrast to the ducted, multi-space reach of a central air handling unit.
What to check on a Split AC Unit.
96 models from Heinen & Hopman in Split AC Unit. Below: the full model list.
What defines this type
A split unit divides the refrigeration circuit across two boxes: an indoor evaporator, wall or ceiling mounted in the space it serves, and an outdoor or weather-exposed condensing unit connected by refrigerant pipe runs. Each split serves one space independently, so a fault on one unit does not take down cooling anywhere else, unlike a central AHU where a single fan or coil failure affects every space on that branch. This independence is why split units are common on the bridge, ECR and individual cabins where redundancy between spaces matters more than shared ductwork efficiency.
Legend
- Indoor evaporator unit
- Condenser fan
- Refrigerant piping (liquid and suction)
- Condenser coil
- Compressor
- Outdoor condensing unit
- Condensate drain
Main components
- Indoor evaporator unit – contains the evaporator coil, blower and filter, mounted directly in the conditioned space.
- Outdoor condensing unit – houses the compressor and air-cooled condenser coil, exposed to weather and salt spray on deck or in a vented enclosure.
- Interconnecting refrigerant pipework – liquid and suction lines running between indoor and outdoor units, a common leak point at flared or brazed joints.
- Expansion device – a capillary tube or thermostatic expansion valve metering refrigerant into the evaporator.
- Condensate drain – gravity or pumped drain removing water condensed off the evaporator coil.
Selection and sizing
Each space is sized independently against its own heat load, not a share of a building-style total. Points to confirm:
- Cooling capacity matched to the specific space's solar gain, equipment heat load and occupancy, since a bridge with large glazing runs hotter than a similarly sized cabin.
- Maximum allowable pipe run length between indoor and outdoor units, which limits how far the outdoor unit can sit from the space it serves.
- Ambient design temperature the outdoor unit must reject heat against, especially for units mounted on an exposed deck in tropical trades.
- Refrigerant type and charge, since longer pipe runs need additional charge beyond the factory pre-charge.
Regulations
Where refrigerant pipework passes through a fire-rated bulkhead or deck, the penetration must maintain the boundary's fire integrity, the same principle applied to AHU ductwork. Beyond that, split units carry fewer specific class requirements than a central system because each circuit is self-contained and does not distribute air between fire zones.
Read the full guide
Typical faults
| Fault | Consequence |
|---|---|
| Refrigerant leak at a flared or vibration-fatigued joint | Gradual capacity loss and eventual compressor short-cycling on low pressure |
| Condensate drain blockage | Water overflow into the cabin or space below the indoor unit |
| Outdoor unit coil corrosion | Falling heat rejection and rising head pressure, worse the longer the unit sits in salt air without rinsing |
| Control board failure from humidity ingress | Erratic operation or total unit shutdown, common on units without a properly sealed control enclosure |
| Compressor short-cycling on low charge | Reduced compressor life and inconsistent room temperature |
What to look for in a supplier
- Marine-grade coil coating on the outdoor unit, not a standard shore residential coil.
- Documented maximum pipe run length and any additional charge calculation for longer runs.
- Indoor unit noise rating, particularly for bridge and cabin installations where quiet operation matters.
- Straightforward retrofit dimensions where the unit replaces an existing split without new ductwork.
Rinse outdoor coils with fresh water on a fixed schedule, not just when capacity starts to fall; salt loading on the fins is progressive and the unit is already down on performance well before it trips on high head pressure.
Models in this type.
The best-documented model of each manufacturer first, then the next — 96 of 96 models in Split AC Unit. Every row links to full specifications, documents and service notes.
Manufacturers.
All 11 manufacturers with models of Split AC Unit. Names with a manufacturer page open it; the others open a search across the full library.
All manufacturersAlso in Air Conditioning.
The other equipment types in this category.
One request. A person reads it and replies by e-mail.
Tell us the manufacturer, the model and what you need — a part, a service call, a second opinion. A person reads every request and replies by e-mail.
No details at hand? A photo of the rating plate or the part is enough — simply attach it to the request.
Three things people ask first.
Is Split AC Unit data free?
Yes. Every model page, every guide and every datasheet for this type is readable without an account. An account adds saved searches and requests, nothing is taken away.
My model is missing — what now?
Send us the nameplate. We identify it by hand, add it to the library, and if you need a part or a service, the request is already on our desk.
Can you source a Split AC Unit part?
Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.