Marine Energy Storage System

A marine energy storage system is a lithium-ion battery bank rated and protected for shipboard use, sized either to shave peak diesel-generator load or to run propulsion and hotel loads alone for a defined hybrid or zero-emission transit.

108models
16manufacturers
10 Oct 2026last updated
Knowledge

What to check on a Marine Energy Storage System.

108 models from 16 manufacturers. Below: the manufacturers at a glance and the full model list.

What defines a marine energy storage system

A marine Energy Storage System (ESS) is a battery installation built around lithium-ion cells, packaged into modules and racks with its own battery management system (BMS), and integrated into the vessel's power management system so it can charge from and discharge into the switchboard under automatic control. It differs from a UPS in duty: a UPS exists to bridge a short gap on a failure of mains power to critical loads, sized in minutes; a marine ESS is a working part of the power plant, sized in kilowatt-hours to carry propulsion or hotel load for minutes to hours, to smooth or "shave" the peaks that would otherwise force a diesel generator to run at poor part load, or to allow fully electric manoeuvring and port stays with generators shut down.

Marine energy storage system layout
Arrangement of a shipboard battery room showing the battery module racks, the cooling air duct and fire suppression nozzles above them, the battery management system, and the cable run out to the switchboard and converter.

Main components

Battery modules and racks

Cells are grouped into modules, modules into racks, each rack fitted with its own fusing, contactors and temperature sensors. Marine lithium-ion chemistries in service include NMC (higher energy density, more sensitive to abuse) and LFP (lower energy density, more tolerant of overcharge and thermal stress); the choice affects both footprint and the fire-fighting arrangement required.

Battery Management System (BMS)

The BMS monitors cell voltage, temperature and current at module level, balances cells, and trips the rack contactors on any parameter outside its set limits. It is the primary protection layer and reports state of charge and state of health to the vessel's power management system.

Read the full guide

Power conversion (DC/AC converters)

Bidirectional converters interface the battery's DC bus with the ship's AC switchboard, controlling charge and discharge rate and following commands from the power management system for peak shaving, spinning-reserve replacement or zero-emission mode.

Thermal management and fire protection

Battery rooms are fitted with dedicated ventilation, often forced air or a liquid-cooled rack design, gas detection for battery off-gassing, and a fixed fire-extinguishing system suited to lithium-ion fires, since a conventional CO2 system cannot stop a cell going into thermal runaway.

Selection and sizing

Sizing starts from the duty the battery must perform: pure peak shaving needs high power for short bursts and modest energy capacity; zero-emission port stays or fully electric short-sea transits need much higher usable energy capacity at correspondingly higher capital cost and weight. Key figures are usable capacity in kWh, continuous and peak discharge power in kW, cycle life at the intended depth of discharge, and round-trip efficiency. Installed location matters as much as electrical rating: battery rooms need to be positioned for straightforward ventilation trunking and for fire boundaries that do not compromise adjacent escape routes.

ParameterRelevance
Usable energy (kWh)Determines duration of zero-emission or peak-shaving operation
Continuous/peak power (kW)Sets how much diesel-generator load can be offset
Cycle life at target DoDDrives expected years in service before capacity fade forces replacement
Chemistry (NMC vs LFP)Trade-off between energy density and thermal stability

Regulations and class

All major class societies have dedicated rules for battery-powered and hybrid propulsion, typically requiring a battery power or battery safety class notation, a hazard identification study, segregation of the battery room from accommodation and machinery spaces by A-class boundaries, dedicated ventilation and gas detection, and a fixed extinguishing system suited to the installed chemistry. IMO's interim guidelines for lithium-ion battery installations on ships and IACS unified requirements are commonly referenced in the approved arrangement. Survey includes periodic testing of the BMS protection functions and of the fire and gas detection systems on the same cycle as the vessel's other safety systems.

Typical faults

  • Cell imbalance — one or more cells drift out of balance with the rest of the rack, reducing usable capacity and, if undetected, driving a cell toward an overvoltage trip.
  • BMS communication fault — loss of data between rack BMS and the power management system forces the rack offline as a protective default, cutting available power exactly when it may be needed.
  • Cooling system failure — elevated rack temperature accelerates capacity fade and, in a worst case, initiates thermal runaway in a cell.
  • Capacity fade beyond specification — normal ageing reduces usable kWh over years of cycling; when it falls below the duty requirement the rack, not just a cell, needs replacement.

What to look for in a supplier

  • Type approval for the specific battery chemistry and rack design from the class society the vessel is built to.
  • A documented thermal runaway propagation test for the rack and enclosure, not only cell-level test data.
  • Remote monitoring and diagnostic support for the BMS, since early detection of cell imbalance is largely a software function.
  • A clear end-of-life and disposal or second-life pathway for the battery modules, agreed before installation.

Treat any BMS-forced rack shutdown as a report, not a nuisance trip: it is the system telling you a cell went outside its safe window, and resetting it without checking the underlying cause is how a battery room fire starts.

Models

Models in this type.

The best-documented model of each manufacturer first, then the next — 100 of 108 models in Marine Energy Storage System. Every row links to full specifications, documents and service notes.

Victron Energy48/60 0 0 DUAL TR ACKER Corvus EnergyBlue Whale ESS 1000 kWh 1000 kWh PBESNMC Marine 1000 kWh 1000 kWh EXIDE TECHNOLOGIES SASEP900 Kongsberg MaritimeEnergy ESS Deckhouse PanasiaPanaGenTM -100 MTUmtu inetic PowerPac/mtu inetic o er ac LeclanchéMarine Battery Module 30-2000 kWh SaftLi-Ion Marine Battery 50-3000 kWh AFRISOABT 160 EST-FloattechOctopus High Energy 10/Octopus High Power 5.8 Praxis AutomationGreenBattery/GreenBattery-3C TorqeedoDeep Blue 80 Victron Energy48/6000 Dual Tracker Corvus EnergyBlue Whale ESS 2000 kWh 2000 kWh PBESNMC Marine 150 kWh 150 kWh EXIDE TECHNOLOGIES SASER450 Kongsberg MaritimeEnergy Products PanasiaPanaGenTM -2300 Victron EnergyBlueSolar 150 Corvus EnergyBlue Whale ESS 500 kWh 500 kWh PBESNMC Marine 300 kWh 300 kWh EXIDE TECHNOLOGIES SASES1300 Kongsberg MaritimeEnergy Storage Converter PanasiaPanaGenTM -250 Victron EnergyEasySolar 48 Corvus EnergyOrca Energy 124 kWh 124 kWh PBESNMC Marine 600 kWh 600 kWh EXIDE TECHNOLOGIES SASEV1600 Kongsberg MaritimeEnergy Storage System PanasiaPanaGenTM -30 Victron EnergyMulti RS Solar 48/6000 Smart LiFePO4 48V 200Ah Corvus EnergyOrca Energy 248 kWh 248 kWh PBESNMC Marine 75 kWh 75 kWh EXIDE TECHNOLOGIES SASEZ600 Kongsberg MaritimeEnergy Storage Unit PanasiaPanaGenTM -500 Victron EnergyMultiPlus 48 Corvus EnergyOrca Energy 496 kWh 496 kWh PBESPower Battery 50-5000 kWh Victron EnergyQuattro-II Corvus EnergyOrca Energy 62 kWh 62 kWh Corvus EnergyOrca ESS 100-10000 kWh Corvus EnergyOrca Energy Storage System (ESS) and Lighthouse hydro00-A25CE-200 ABBOnboard DC Grid ESS 1000 kWh 1000 kWh Xantrex975-0289-01-01 hydro00-I25KC-200* ABBOnboard DC Grid ESS 2000 kWh 2000 kWh MTU40ft hydro00-I25KD-200* ABBOnboard DC Grid ESS 250 kWh 250 kWh hydro90-A25CE-200 ABBOnboard DC Grid ESS 500 kWh 500 kWh hydroBA EHP C 10000-350-540 hydroBA EHP C 1250-250-540 hydroBA EHP C 1250-350-540 hydroBA EHP C 2500-250-540 Victron Energy100-50 hydroBA EHP C 2500-350-540 Victron Energy110-100 hydroBA EHP C 3000-250-540 Victron Energy120- hydroBA EHP C 3000-350-540 Victron Energy140-100 hydroBA EHP C 4000-250-540 Victron Energy200-100 hydroBA EHP C 4000-350-540 Victron Energy4 x 20 x JA Mono-Crystalline Solar Panels 335Wp/BYD B-Box Pro hydroBA EHP C 5000-250-540 Victron Energy4k hydroBA EHP C 5000-350-540 Victron Energy4k5 hydroBA EHP C 6000-250-540 Victron Energy55-32 hydroBA EHP C 6000-350-540 Victron Energy6k5 hydroBA EHP C 7000-250-540 Victron Energy70-100 hydroBA EHP C 7000-350-540 hydroBA EHP C 8000-250-540 hydroBA EHP C 8000-350-540 hydroBA EHP C 9000-350-540 hydroEBV 1-40 hydroEBV 2 hydroEBV 5-40 hydroEBV0 hydroEBV5-40 hydroEBV90-I20PA-200 hydroEBV90-I20PA-200-1 hydroEBV90-I25KC-200 hydroEBV90-I25LA-200 hydroEHP-C-0010-250-080-AF00AA0000 hydroEHP-C-0010-250-080-AF00AAP000 hydroEHP-C-0020-250-080-AB00AA0000 hydroEHP-C-0020-250-080-AF00AA0000 hydroEHP-C-0020-250-080-AF00AAP000 hydroEHP-C-0030-250-080-AF00AA0000 hydroEHP-C-0040-250-080-AF00AA000 hydroEHV 1-690
By manufacturer

Manufacturers.

All 16 manufacturers with models of Marine Energy Storage System. Names with a manufacturer page open it; the others open a search across the full library.

All manufacturers
Related types

Also in Battery & UPS Systems.

The other equipment types in this category.

Battery Management System (BMS)Battery/UPSLead-Acid Battery BankLithium-Ion Battery System (ESS)Marine UPSMarine UPS System
Would you like to know more?

One request. A person reads it and replies by e-mail.

Tell us the manufacturer, the model and what you need — a part, a service call, a second opinion. A person reads every request and replies by e-mail.

No details at hand? A photo of the rating plate or the part is enough — simply attach it to the request.

Frequently asked

Three things people ask first.

Is Marine Energy Storage System data free?

Yes. Every model page, every guide and every datasheet for this type is readable without an account. An account adds saved searches and requests, nothing is taken away.

My model is missing — what now?

Send us the nameplate. We identify it by hand, add it to the library, and if you need a part or a service, the request is already on our desk.

Can you source a Marine Energy Storage System part?

Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.