The accommodation sprinkler system is an automatic, pressurised network that opens sprinkler heads by heat alone and starts extinguishing before the crew reaches the space, the one part of the ship's fire fighting outfit that acts without anyone touching a valve.

3models 2manufacturers
Models

Models in this type.

The 3 models with the most complete data of 3 in Sprinkler System (Accommodation). Every row links to full specifications, documents and service notes.

By manufacturer

Manufacturers.

All 2 manufacturers with models of Sprinkler System (Accommodation). Every name opens a search across the full library.

Related types

Also in Fire Fighting.

The other equipment types in this category.

CO₂ Fixed System (Engine Room + Cargo)Fire Detection SystemFire-Fighting EquipmentFoam System (Deck)Portable Extinguishers (CO₂, Powder, Foam)SCBA (Self-Contained Breathing Apparatus)Water Mist System (Hi-Fog)
Knowledge

What to check on a Sprinkler System (Accommodation).

Unlike the fire main and hydrants, which need a crew member to run out a hose, the accommodation sprinkler system is automatic: each head contains a heat-sensitive element that releases at a set temperature, opening only that head and the ones near it rather than flooding the whole system. It is required specifically for accommodation, service and control spaces because these are the areas most likely to be occupied and least likely to have someone standing by with a hose when a fire starts, typically at night.

What makes this type

Unlike the fire main and hydrants, which need a crew member to run out a hose, the accommodation sprinkler system is automatic: each head contains a heat-sensitive element that releases at a set temperature, opening only that head and the ones near it rather than flooding the whole system. It is required specifically for accommodation, service and control spaces because these are the areas most likely to be occupied and least likely to have someone standing by with a hose when a fire starts, typically at night.

Accommodation sprinkler system, flow diagram
Flow diagram of an accommodation sprinkler system showing the sprinkler pump filling the pressure tank, the distribution main through a section valve with flow switch to the sprinkler heads, and the flow switch signal to the fire alarm panel.

Main components

Pressure tank

A charged tank, part air and part fresh water, that gives instant pressure to the first head that opens before the pump has time to start.

Sprinkler pump

Automatically starts on a pressure drop in the system to sustain flow once the tank's stored pressure is used up, and must be capable of running the system at its designed simultaneous head count.

Sprinkler heads

Glass bulb or fusible link elements rated to open at a set temperature, chosen higher in spaces like galleys where ambient heat is naturally elevated so the head does not open on cooking heat alone.

Section valves and alarm panel

Each section of piping has an isolating valve and a flow switch that triggers an alarm at the bridge and a local indicator showing which section has activated, so the crew knows where to go without searching the ship.

Piping network

A dedicated, always-charged pipe run separate from the general fire main, sized so pressure and flow are maintained even with several heads open simultaneously in one section.

Selection / sizing

  • Number of sections and the largest number of heads expected to open together in one section sets pump capacity.
  • Head temperature rating matched to the space: standard rating for cabins and public rooms, higher rating for galleys and machinery adjacent spaces.
  • Pressure tank capacity, sized to bridge the gap before the pump reaches full pressure.
  • Corrosion-resistant piping given the system stands charged with water permanently, unlike a dry system.

Regulations / Class

SOLAS Ch. II-2 requires automatic sprinkler, fire detection and fire alarm systems in accommodation, service spaces and control stations on passenger ships and is applied to many cargo ship accommodation blocks as an alternative means of protection. The system must give an audible and visual alarm at a continuously manned station identifying the section, and class rules require periodic testing of pump start, pressure tank charge and section valve operation, verified at annual and renewal survey.

Typical faults

FaultCauseConsequence
Pressure tank low on chargeSlow air leak, not topped up at roundsDelay before pump starts, weak initial discharge
Section valve left shut after maintenanceNot reopened and logged after work on a branchWhole section unprotected without any alarm indication
Head painted overDeck maintenance painting overspray onto sprinkler headsHeat-sensitive element insulated, may fail to open
Pump fails to auto-startPressure switch fault or breaker left openSystem relies on tank pressure only, exhausted within minutes

What to look for in a supplier

  • Heads and valves with current type approval certificates matching the flag and class requirements, not just a generic fire sprinkler product.
  • Documented hydraulic calculation showing the pump and tank meet the simultaneous operation requirement for the largest section.
  • Spare heads held in the correct temperature ratings for each space category, not a single rating for the whole ship.

Never paint a sprinkler head during accommodation maintenance, and check the section valve log every time work is done on a branch line. An unlogged shut valve is the most common reason a sprinkler system fails to respond when it is actually needed.

Search by manufacturer AFRISOWISKASwagelokAlfa Laval S.p.A.MAN Energy SolutionsWärtsiläEndress+HauserABB MarineAlfa LavalMacGregorNovenco MarineCarrier MarineSiemens MarineHeinen & HopmanDaikin Marine
Would you like to know more?

One request. A person answers within 24 hours on working days.

Tell us the manufacturer, the model and what you need — a part, a service call, a second opinion. Our desk asks the right suppliers from a network of over 114,000 companies and comes back with a quote or a sourcing plan, not a search page.

Frequently asked

Three things people ask first.

Is Sprinkler System (Accommodation) data free?

Yes. Every model page, every guide and every datasheet for this type is readable without an account. An account adds saved searches and requests, nothing is taken away.

My model is missing — what now?

Send us the nameplate. We identify it by hand, add it to the library, and if you need a part or a service, the request is already on our desk.

Can you source a Sprinkler System (Accommodation) part?

Yes. Tell us the manufacturer, the model and what you need — our desk asks the right suppliers from a network of over 114,000 companies and comes back with a quote or a sourcing plan.