CO₂ Fixed System (Engine Room + Cargo)
A fixed CO2 system floods an enclosed space with enough carbon dioxide to drop the oxygen level below what a fire can sustain, and because that same concentration will suffocate anyone still inside, the release sequence exists to stop that happening by accident, not just to fight the fire.
What to check on a CO₂ Fixed System (Engine Room + Cargo).
1 models from International Paint in CO₂ Fixed System (Engine Room + Cargo). Below: the full model list.
What defines this type
A fixed CO2 system is a total flooding fire suppression installation: CO2 is stored as a liquid under pressure in cylinders and, on release, discharged through a fixed pipe network to nozzles distributed through the protected space until the oxygen concentration falls low enough to stop combustion. Unlike water-based systems it suppresses by displacing oxygen rather than cooling the fire, which is why it is chosen for spaces where water would spread burning fuel or damage machinery beyond the fire itself — the engine room, and cargo holds where hoses or sprinklers are impractical. It only works if the space can actually hold the gas, which is why boundary integrity — closed doors, sealed penetrations, shut ventilation — is as much a part of the system as the cylinders.
Legend
- Distribution piping
- Discharge nozzles
- CO2 cylinder bank
- Protected space (engine room)
- Pre-discharge alarm
- Release station (outside space)
Main components
- CO2 cylinder bank — high-pressure cylinder storage, the bulk of the system's volume, usually located in a dedicated room outside the protected space.
- Pilot cylinder — a smaller cylinder whose release initiates the main bank discharge.
- Distribution manifold and pipework — carries the gas from the cylinder room to the nozzles.
- Release nozzles — sized and positioned to achieve even distribution through the protected volume.
- Alarm and time-delay unit — sounds an audible and visual pre-discharge warning and holds the release for a set period to allow evacuation.
- Boundary closures — fire dampers and ventilation shutdowns that must close, automatically or manually, before or during release.
Selection / sizing
The protected space's net volume sets the required CO2 quantity, calculated to reach the design flooding concentration for that space type within the required discharge time. Cylinder count and pipe sizing both follow from that figure — enough cylinders to deliver the total quantity, and pipework sized to deliver it within the time the standard requires. Spaces with a particular fire hazard concentrated in one area, such as a paint locker or a specific piece of cargo equipment, may need local application nozzles in addition to the total flooding arrangement for the main space.
Regulations / Class
SOLAS Chapter II-2 together with the Fire Safety Systems (FSS) Code sets the requirements for fixed CO2 systems: the quantity required per protected volume, the discharge time, the sequence and duration of the pre-discharge alarm, required signage at entrances and at the release station, and the location of the manual release control outside the protected space in a position that stays accessible during a fire. Class survey checks cylinder weight or pressure at periodic intervals and requires hydrostatic testing of cylinders on the schedule the rules set.
Read the full guide
Typical faults
- Cylinder weight loss from a leaking valve — found only at periodic weighing, means the system would under-dose on release and never reach flooding concentration.
- Corroded or seized release valve — the system fails to discharge on demand when actually needed.
- Damaged or blocked nozzles — uneven gas distribution leaves pockets of the space where the fire is not suppressed.
- Faulty alarm sequencing — either no pre-discharge warning, a genuine safety risk, or nuisance alarms that lead crew to distrust and bypass the system.
- Boundary leakage — open doors or dampers that fail to close mean the flooding concentration is never reached even with a full, correct discharge.
What to look for in a supplier
- A cylinder testing and weighing service that actually reaches the vessel's ports of call.
- A documented quantity calculation against the vessel's actual protected volumes, not a generic figure.
- Compatibility with existing pipework where only part of an older system is being replaced.
- Spares held for release valves and pilot cylinders, which are the parts most often found faulty at survey.
CO2 is lethal in the space it protects — the pre-discharge alarm, headcount and evacuation procedure matter as much as the cylinders themselves, and crew drills should treat them that way.
Models in this type.
The best-documented model of each manufacturer first, then the next — 1 of 1 models in CO₂ Fixed System (Engine Room + Cargo). Every row links to full specifications, documents and service notes.
Manufacturers.
All 118 manufacturers with models of CO₂ Fixed System (Engine Room + Cargo). Names with a manufacturer page open it; the others open a search across the full library.
All manufacturersShow all 118 manufacturers
- AdvanTec Manufacturing Canada, Inc.1
- Aker Solutions AS1
- Antti-Teollisuus1
- AWG Fittings GmbH1
- Brødrene AA AS1
- Bristol Uniforms Ltd1
- Ceasefire Industries U.K. Limited2
- CheckFire Ltd1
- China Marine Windows Shipyard Co., Ltd.1
- Dalian Luminglight Co., Ltd1
- Detector Electronics1
- DONGNAN ELEVATOR CO.,LTD.1
- Draeger Safety UK2
- DSG GmbH1
- Egger Kunststoffe GmbH & Co. KG1
- Entel UK Limited1
- EUROPAIR1
- European Safety Systems1
- Fehrmann GmbH1
- Fire Eater A/S1
- Fireboy-Xintex UK Operations Ltd1
- FirePro Systems Ltd1
- Firsquare Energy (Shanghai) Co., Ltd.1
- Fitech Engineering Pte Ltd1
- FlamePro Global Ltd1
- G W SPRINKLER1
- G. Theodor Freese GmbH1
- Giordani Giancarlo S.r.l.1
- Grama Blend Gmbh1
- Haein Industrial Co. Ltd.2
- Haes Technologies Limited1
- Halton Wales (MEI) Ltd1
- Harvik Rubber Industries Sdn. Bhd.1
- Honeywell International Inc.1
- International Paint1
- Jewel Fire2
- Jiangsu Hongyu Marine Equipment Limited Company1
- Jiangsu Josun Air Conditioner Co., Ltd.1
- JiangSu Sooloong Hose MFG.CO.,Ltd.1
- Johnson Controls International Korea, Inc.1
- Langfang The Great Wall Ship Glass Belt Co., Ltd.1
- LMG Finland Oy1
- MANDALS A Michelin Group1
- Marioff1
- Mascoat1
- Matre Maskin1
- Microdata Due1
- Motorola Solutions Systems Polska Sp. z.o.o1
- Nanjing Hengxinda1
- Navutec Co., Ltd.1
- NewAge Fire Fighting Co. Ltd.2
- Niikura Kogyo1
- NingBo Zhengxin Fire-Fighting Equipment Co. Ltd2
- NVL B.V. & Co. KG1
- Remitite Co., Ltd.1
- Respirex International Limited1
- SAINT-GOBAIN BYGGEVARER AS1
- SENTURA GROUP LTD1
- SEVO Systems, Inc.1
- Shenzhen Foresight CO.,LTD1
- Sun Chemical1
- Taicang Fushi Machinery & Equipment Co., Ltd.1
- Taicang Haichang1
- Taicang Yongming Paien Machine1
- Taizhou Sanjiang Fire Control Equipment Co., Ltd.1
- Tanktech1
- Tata Steel Maubeuge2
- Thrane & Thrane1
- Tyco Building Services Products B.V1
- Tyco Fire & Security1
- Tyco Fire Products, LP2
- Tyco Fire Protection Products2
- UNIFRAX1
- Unitor2
- Viking Life-Saving Equipment2
- Viking Sapphire1
- VTI Marine Equipments (Shanghai) Co., Ltd.1
- WITTUR1
- Wuxi Dongzhou Marine Equipment1
- Wuxi MNET Equipment Tech Co., Ltd.1
- Zhejiang Hongjing Textile Technology Co., Ltd.1
- Zhejiang Orientx Fire Safety Equipment Co.,Ltd2
Also in Fire Fighting.
The other equipment types in this category.
One request. A person reads it and replies by e-mail.
Tell us the manufacturer, the model and what you need — a part, a service call, a second opinion. A person reads every request and replies by e-mail.
No details at hand? A photo of the rating plate or the part is enough — simply attach it to the request.
Three things people ask first.
Is CO₂ Fixed System (Engine Room + Cargo) data free?
Yes. Every model page, every guide and every datasheet for this type is readable without an account. An account adds saved searches and requests, nothing is taken away.
My model is missing — what now?
Send us the nameplate. We identify it by hand, add it to the library, and if you need a part or a service, the request is already on our desk.
Can you source a CO₂ Fixed System (Engine Room + Cargo) part?