This general bucket covers marine cable outside standard power distribution - control and instrumentation, fibre optic data, coaxial for radar and comms, and heating trace cable - each built to the same marine fire standard but carrying signal or heat, not load current.
8 models from Twin Disc in General Marine Cables. Below: the full model list.
Power distribution cable, rated 0.6/1 kV and similar classes, has its own listing. This general group is where the rest of a ship's cable plant sits: control and instrumentation cable carrying low-current signals between sensors and controllers, fibre optic cable carrying data for navigation and automation networks, coaxial cable for radar and communications antennas, and specialist types such as heating trace cable for tank and pipe frost protection. All of it is built to marine fire and mechanical standards, but none of it is chosen the way power cable is, because current-carrying capacity is not the limiting factor.
Legend
Multicore, often screened to keep electrical noise off a low-level signal, and sized by core count and screening rather than conductor cross-section, since the current involved is small.
Carries data for integrated bridge systems, automation networks and increasingly for CCTV and IT backbones, immune to electromagnetic interference in a way copper cable is not, but needing a properly terminated connector and a minimum bend radius that a careless installation routinely violates.
Feeds radar, GPS, VHF and satellite communication antennas; signal loss over the cable run is a real design factor at the frequencies these systems use, so run length and cable grade are chosen together, not the cable alone.
Self-regulating or fixed-wattage electric heating cable wrapped along pipework carrying viscous fuel or cargo that must be kept above its pour point, controlled by a thermostat rather than run continuously.
Each type is selected on the parameter that actually limits it: screening effectiveness and core count for control cable, attenuation and connector compatibility for fibre and coaxial runs, and heat output per metre matched to pipe insulation for heating cable. Fire performance class still applies across all of them, following the same routing and segregation logic as power cable.
The IEC 60092 series covers construction and fire testing for shipboard cable generally, including the control, instrumentation and low-power types in this group. SOLAS Chapter II-2 routing and segregation requirements apply here too, since a fibre backbone for the integrated bridge system still needs to survive a fire in the space it passes through if it serves a safety function. Heating trace cable installation is normally covered by the equipment manufacturer's certified installation method rather than a cable-specific class rule, since the hazard being managed is electrical, not structural.
| Cause | Consequence |
|---|---|
| Fibre bend radius violated during installation | Increased attenuation or fibre fracture, intermittent data faults that are hard to trace |
| Coaxial connector corrosion at an exposed antenna feed | Rising signal loss, degraded radar or communications range before outright failure |
| Control cable screen not earthed at both ends correctly | Noise pickup, false signals at the controller |
| Heating trace cable thermostat failure | Either no heat, risking a blocked line, or continuous heating and local overheating |
Log fibre optic attenuation at commissioning and check it again after any major refit - a link that still works can be running with far less margin than it had on day one, and a small further loss is what finally breaks it.
The best-documented model of each manufacturer first, then the next — 8 of 8 models in General Marine Cables. Every row links to full specifications, documents and service notes.
All 157 manufacturers with models of General Marine Cables. Names with a manufacturer page open it; the others open a search across the full library.
All manufacturersThe other equipment types in this category.
Tell us the manufacturer, the model and what you need — a part, a service call, a second opinion. A person reads every request and replies by e-mail.
No details at hand? A photo of the rating plate or the part is enough — simply attach it to the request.
Yes. Every model page, every guide and every datasheet for this type is readable without an account. An account adds saved searches and requests, nothing is taken away.
Send us the nameplate. We identify it by hand, add it to the library, and if you need a part or a service, the request is already on our desk.
Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.