A reefer container carries its own complete refrigeration plant built into one end of the box, relying only on the ship for electrical power and, on some vessels, hold air circulation, unlike the ship's own fixed provisions cold rooms.
What to check on a Container Reefer Unit.
1 models from Daikin Marine in Container Reefer Unit. Below: the full model list.
What a container reefer unit is, on board a ship
A reefer container carries its own complete refrigeration plant built into one end of the box - compressor, condenser, evaporator and controller - rather than relying on the ship's own cooling system. The ship's role is limited to supplying three-phase electrical power to each container's socket and, on a purpose-built container or reefer vessel, forced air circulation through the hold for the units' condenser cooling; the ship does not refrigerate the cargo itself. This is what separates a reefer container from the fixed provisions cold rooms elsewhere on the same ship, which share one central plant.
Legend
- machinery end wall
- container box (cargo space)
- return air along ceiling
- condenser + fresh air intake
- compressor
- ship power socket
- evaporator coil
- cold supply air along floor
Main components
Integral machinery package
Compressor, condenser and evaporator fan section built into the container's front wall, drawing power through a standard reefer plug at the container base or top depending on design.
Microprocessor controller
Holds setpoint, records temperature history for the voyage, and on modern units reports remotely to shore or ship monitoring systems - this logged data is what a shipper relies on to prove the cargo was kept in range.
Read the full guide
T-bar floor and air delivery
A ridged floor under the cargo creates an air channel so cooled air is forced up through the load rather than just around it, essential for perishables packed to the door.
Controlled/modified atmosphere option
Some units add CO2 and O2 control for produce that needs a modified atmosphere in transit, on top of straight temperature control.
Selection and sizing
Selection is less about physical sizing, since reefer containers come in standard TEU/FEU dimensions, and more about matching refrigerant type, controller generation and monitoring compatibility to the operator's fleet and the ship's power and monitoring infrastructure. Vessels with a dedicated reefer monitoring system need units whose controllers speak the same protocol, or a conversion plug, to get remote alarm and temperature data rather than relying on deck rounds alone.
Regulations and class
Refrigerant selection is under increasing pressure from the Montreal Protocol and IMO GHG-related instruments driving fleets away from high-GWP refrigerants toward lower-impact alternatives. Power supply and socket arrangements on the ship side fall under the vessel's electrical classification, and reefer plug circuits typically carry their own overload and ground fault protection separate from the main ship's power distribution.
Typical faults
- Loss of ship power to the socket - a tripped breaker or damaged plug/socket connection stops the unit cold regardless of the container's own condition, and is the single most common cause of a reefer excursion at sea.
- Condenser airflow restriction - stacking or lashing gear blocking the condenser grille raises head pressure and can trip the unit on high pressure protection.
- Controller sensor drift - a return-air or supply-air sensor reading incorrectly can hold the unit on setpoint by its own display while the actual cargo temperature drifts.
- Door seal or drain blockage - lets in humid air or traps meltwater, both of which damage delicate produce even with the refrigeration plant working correctly.
What to look for in a supplier
- Controller and monitoring protocol compatible with the operator's existing reefer monitoring system.
- Refrigerant type aligned with current and near-term environmental regulation, not a soon-to-be-restricted charge.
- Service network and spare parts availability across the actual ports the containers move through, not just the country of manufacture.
Before opening up a faulty reefer container, check the socket and breaker on the ship side first - a large share of reported unit failures turn out to be a power supply problem at the plug.
Models in this type.
The best-documented model of each manufacturer first, then the next — 1 of 1 models in Container Reefer Unit. Every row links to full specifications, documents and service notes.
Manufacturers.
All 5 manufacturers with models of Container Reefer Unit. Names with a manufacturer page open it; the others open a search across the full library.
All manufacturers in the libraryAlso in Refrigeration.
The other equipment types in this category.
Write to us about this model — the answer comes by e-mail.
Name the make and the model and what the job is: a spare, a service call, a second opinion on a data sheet. We answer by e-mail.
No details at hand? A photo of the rating plate or the part is enough — simply attach it to the request.
Questions that come up with this equipment.
Is Container Reefer Unit data free?
Yes. Every model page, every guide and every datasheet for this type is readable without an account. An account adds saved searches and requests, nothing is taken away.
My model is missing — what now?
Send us the nameplate. We identify it by hand, add it to the library, and if you need a part or a service, the request is already on our desk.
Can you source a Container Reefer Unit part?
Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.