OceanSphereFree accountLog inDEENPL
OceanSphereENGINES
Library› Engine Room› Automation & Control› Remote I/O Module
Automation & Control

Remote I/O Module

A remote I/O module collects sensor signals and drives actuators close to the machinery, then passes them to the PLC or automation system over a bus. It replaces long bundles of individual cables with a short local connection and a single data link.

80models13manufacturers
Knowledge

What to check on a Remote I/O Module.

80 models from 13 manufacturers. Below: the manufacturers at a glance and the full model list.

What sets remote I/O apart

In a classical automation system every sensor and valve is wired back to a central cabinet. With remote I/O, an input/output module is installed near the equipment, collects the signals from the field devices and sends them to the controller over a fieldbus or industrial Ethernet. That saves cable, reduces installation time and makes it easier to extend a system later. On a ship, the modules sit in engine rooms, on deck and in local panels, so they have to cope with heat, vibration and electrical noise from converters and generators. A single module may carry dozens of signals, which makes its failure more significant than that of a single sensor.

Read the full guide

Main designs

  • Modular rail-mounted I/O systems, where a bus coupler is extended with plug-in input and output modules
  • Compact I/O blocks with a fixed number of channels for a defined task
  • Intrinsically safe I/O for signals leading into hazardous areas
  • I/O with built-in diagnostics and sometimes hot-swap capability, so a module can be exchanged while the system runs
  • Gateway and interface modules that connect field devices or serial equipment to the control network

Main components

  • Bus coupler or head station, which holds the network address and the bus interface
  • Digital input and output modules for switches, limit contacts, valve solenoids and relays
  • Analogue input modules for 4-20 mA, voltage and temperature signals such as PT100 sensors
  • Analogue output modules for control valves and drives
  • Power feed and field-supply modules that provide protected supply to the sensors and actuators

Selection and sizing

  • Signal types and number of channels, with a reserve for later additions
  • Bus protocol that suits the controller, for example PROFIBUS, PROFINET, Modbus, CANopen or EtherCAT
  • Galvanic isolation and surge protection, so a fault in one channel does not travel into the rest of the system
  • Diagnostics: wire-break and short-circuit detection and channel-level fault reports
  • Redundancy of the bus, power supply or coupler where the function is safety-relevant
  • Environmental data: temperature range, vibration, humidity and conformal coating for a harsh engine room

Regulations and class

Automation components used for essential services need type approval from the classification society, including tests for vibration, temperature, humidity and electromagnetic compatibility. The certificate covers a defined product range and firmware status, so a module from the same family but a different version may not be covered. Safety-related I/O used in shutdown or fire-detection functions may need an additional safety integrity level rating under the relevant functional-safety standard.

Typical faults

  • Loose or corroded terminals, causing intermittent signals that look like random sensor faults
  • Bus communication loss from damaged cables, missing termination or duplicate addresses
  • Failed field power supply or a blown fuse, which takes a whole group of channels down
  • Electrical noise on analogue inputs from poor shielding or a ground loop, showing as unstable readings
  • Module defects after a surge, with a single channel going stuck at a fixed value
  • Firmware or configuration mismatch after a module is replaced without matching the stored setup

What to look for in a supplier

  • A type-approval certificate that names the module series and the firmware versions covered
  • Long-term availability of the same module generation, since a discontinued module may force a larger redesign
  • Configuration backup and replacement procedure, so a new module takes over without reprogramming
  • Plug-in terminals and labelling that match the existing wiring
  • Technical support for the chosen bus protocol and its commissioning tools

Keep a spare coupler and one spare module of each type in the engine control room, with the configuration file stored on paper or a separate drive. It turns a night-time alarm into a ten-minute swap.

Models

Models in this type.

The best-documented model of each manufacturer first, then the next — 80 of 80 models in Remote I/O Module. Every row links to full specifications, documents and service notes.

emerson392927-01-2 Phoenix ContactAXIOLINE Modules & Smart Managed Compact Switch WAGOWAGO I/O SYSTEM 750 Pepperl+FuchsFieldbus devices Schneider Electric Industries SASTeSys™ island - Bus coupler (TPRBCEIP, TPRBCPFN), I/O Modules (TPRDG4X2, TPRAN2X1), Voltage Interface Module (TPRVM001) Weidmüller Interfaceu-remote I/O-System DEIFCIO 116, CIO 208, CIO 308 Parker Hannifin Manufacturing FinlandIOM-10 [46WIOM; 46WIOM_I; 46WIOM_I_SP] R. STAHL SchaltgeräteRemote I/O System Type IS1 and IS1+ Rockwell Automation Asia Pacific Business Center1734-A...; -T..; -P..;-E..;-RTB.; -I...; -O...; -VHSC..; -SSI; -D.. Siemens AG GWAAS-i SlimLine Compact modules VeinlandMIS-Modular Interfacing System etaEM12D-TIO-000-DC24V-40A emerson392927-02-0 Phoenix ContactAXIOLINE Smart Elements Series WAGOWAGO I/O-System 750/753 Pepperl+FuchsRemote I/O LB/FB/MFT Schneider Electric Industries SASTeSys™ island:TPRSM001 SIL Interface Module Weidmüller Interfaceu-remote I/O-System, u-control I/O-System emerson392927-03-9 Phoenix ContactInline Modules WAGOWAGO I/O-System 750XTR emerson3DIH16 emerson3DIS16 emerson3MIX12 emerson3MSG12 emerson8601-FT-NI emerson8602-FT-ST emerson8603-FT-FU emerson8604-FT-FU emerson8605-FT-TC emerson8606-FT-RT emerson8607-FT-TC emerson8608-FT-NI emerson8610-FT-NA emerson8611-FT-FU emerson8612-FT-NA emerson8615-FT-4W emerson8616-FT-FU emerson8707-CA-08 emerson8709-CA-08 emersonAI-12 emersonAI-16 emersonAPP 485 emersonD301228X012 emersonD301243X012 emersonD301274X012 emersonD301277X012 emersonD301573X012 emersonD301593X012 emersonD301637X012 emersonD301705X012 emersonD301712X012 emersonDIT16 emersonDIT3DOH16 emersonDIT3DOS16 emersonDOT16 emersonFB 3000 emersonFB107:62591 emersonFB107:AIDI emersonFB107:HART emersonFB107:IO1 emersonFB3000 emersonFB3000 OUT08 emersonHRT04 emersonHRT3AODO8 emersonHRT3OTSG8 emersonMIO12 emersonMIO3HRT04 emersonMIO3HTSG4 emersonOUT08 emersonOUT3DIH16 emersonOUT3DIS16 emersonPAC8000 emersonROC800-Series emersonROC800:AO emersonROC800:APM emersonROC800:DI emersonROC800:DO emersonROC800:PI
80 models
By manufacturer

Manufacturers.

All 13 manufacturers with models of Remote I/O Module. Names with a manufacturer page open it; the others open a search across the full library.

All manufacturers
Related types

Also in Automation & Control.

The other equipment types in this category.

Alarm Monitoring & Control System (AMCS)Alarm Monitoring SystemCyber Security SolutionDP SystemHMI Panel & Industrial ComputerIntegrated Automation System (IAS)Level SwitchPlanned Maintenance System (PMS)Power Management System (PMS)Programmable Logic Controller (PLC)Propulsion Remote Control SystemRadio Remote ControlSafety System (ESD/F&G)Vessel Data Platform / Fleet Performance Software
Would you like to know more?

One request. A person reads it and replies by e-mail.

Tell us the manufacturer, the model and what you need — a part, a service call, a second opinion. A person reads every request and replies by e-mail.

Frequently asked

Three things people ask first.

Is Remote I/O Module data free?

Yes. Every model page, every guide and every datasheet for this type is readable without an account. An account adds saved searches and requests, nothing is taken away.

My model is missing — what now?

Send us the nameplate. We identify it by hand, add it to the library, and if you need a part or a service, the request is already on our desk.

Can you source a Remote I/O Module part?

Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.