The MOPX series is the clarifier counterpart to the MAPX purifier series from Alfa Laval. It operates in single-phase mode (no water interface) and is therefore primarily designed for lube oil cleaning. On vessels with 2-stroke main engines often employed as a dedicated lube oil separator while the MAPX runs in parallel as fuel oil purifier. Production discontinued approximately 2005, successor is the universal ALCAP S series, which can automatically switch between both modes.

Alfa Laval (Sweden) MOPX Series
900-12,000 l/h
Capacity
Lube Oil
Medium

Components & Design

Component data being added…

Technical Data

type Disc-Stack Centrifugal Separator (Clarifier)
variant count approx 5
period start year 1978
period end year 2005
drive type Electric
construction Cast iron frame, stainless steel bowl
successor series ALCAP S-Series

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Schuessel-/Teller-Erosion

Paring disc, top disc, mud ports check for dull spots/wash-out; erosion depth >0.2 mm (bowl/cap) or >0.5 mm (other) = replacement.

Dichtungsringe

Leaks at cover/bolted joints/mud outlet; gasket rings (EPDM) change every 6000–8000 h, original parts only.

Kugellager

Check vibration/noise; bearings change in pairs every 12000–16000 h, lubricate correctly; do not increase throughput during vibration.

Riemen & Kupplung

Belts every 3000 h (tension per manufacturer), cracks/wear; coupling check for axial play (>0.5 mm = fault), corrosion.

Stromaufnahme/Verschmutzung

Monitor current consumption nominal/actual; clean bowl during shutdown; check pre-filtration + lubrication; limit sludge volume.

Type-general inspection and maintenance points for this equipment category — not model-specific.

Service & Maintenance

Bowl overhaul every 4,000-6,000 hrs. Clarifier mode requires no gravity disc — water seal not needed. Back-pressure check monthly. Sludge tank level monitoring daily.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Same frame as MAPX — many parts interchangeable. Keep onboard: O-ring kit, friction pads, 1 spare discharge valve. Disc stacks: order 3 months ahead for obsolete models.
Equipment Model #37654 · discontinued