OceanSphereENGINES
Library› Engine Room› Turbochargers› Turbocharger› Hitachi HT-C HT-71C
Hitachi

HT-C HT-71C

Turbocharger · Turbochargers

Technical data from manufacturer or class sources · not yet verified by a person​‍​‍⁠⁠‌​⁠‌⁠​​​⁠​‌‍⁠⁠
Hitachi in the SpecCodex register — view brand page →

Hitachi HT-C HT-71C — HT-C, 40000 kW max.

Specifications

Technical data.reference — unverified

Do you have the manufacturer datasheet for this model? Send it with the enquiry form — we check it and name the source.

Frame SizeHT-71C
Power max (kW)40000
Inspection

Inspector Detail

Common issues

  • Bearing wear (journal and thrust bearings) leading to increased axial/radial clearances and vibration.
  • Compressor fouling due to intake air contamination or oil carry-over, reducing efficiency and air flow.
  • Turbine fouling (soot deposition) on nozzle ring and turbine blades, impacting engine performance and increasing exhaust back pressure.
  • Oil leakage from bearing housing seals, often visible externally or indicated by oil in the compressor/turbine discharge.
  • Foreign Object Damage (FOD) to compressor or turbine blades, causing imbalance and potential catastrophic failure.
  • Surging, often indicated by fluctuating boost pressure and unusual noises, potentially due to engine load changes, fouling, or turbocharger malfunction.
  • Cracks or erosion on nozzle ring and turbine blades due to high temperatures and corrosive exhaust gases.
  • Vibration due to rotor imbalance, bearing wear, or structural issues, detectable through monitoring or unusual noise.

Inspection checklist

  • Check axial and radial clearances of the rotor shaft using a dial gauge (refer to manufacturer's manual for specific limits).
  • Inspect compressor wheel for fouling, erosion, or damage to blades. Ensure air filter is clean and intact.
  • Inspect turbine wheel and nozzle ring for fouling, erosion, cracks, or foreign object damage (requires opening gas casing).
  • Verify lubricating oil pressure and temperature at turbocharger inlet/outlet are within specified ranges.
  • Check for any oil or gas leaks from casing joints, bearing housing, or drain lines.
  • Assess overall vibration levels and listen for unusual noises (e.g., grinding, whistling, rubbing).
  • Inspect security of mounting bolts, insulation, and connections for air, exhaust, and oil lines.
  • Ensure drain lines from bearing housing are clear and free-flowing.
  • Check condition of turbocharger washing nozzles and ensure they are not clogged.

Service intervals

Daily/Weekly ChecksVisual inspection, monitoring of operating parameters (RPM, pressures, temperatures, vibration).
8,000 - 12,000 Running HoursMinor inspection: Compressor washing, visual inspection of compressor wheel, oil filter replacement, check for oil leaks.
16,000 - 24,000 Running HoursIntermediate inspection: Bearing inspection/replacement (journal and thrust), thorough cleaning of gas and air sides, axial/radial clearance checks, inspection of nozzle ring and diffuser.
32,000 - 48,000 Running HoursMajor Overhaul: Complete dismantling, inspection of all components, replacement of bearings, seals, gaskets, and potentially nozzle ring/diffuser. Rotor balancing as required. (This is the typical interval for a comprehensive overhaul of the rotating assembly).

Typical intervals for this design class, not the manufacturer’s figures for your model. The manufacturer’s manual is binding.

Typical wear limits

Axial Clearance (Rotor)New: 0.15 - 0.25 mm. Max wear limit: +0.10 to +0.15 mm over new (e.g., 0.30 - 0.40 mm total).
Radial Clearance (Rotor)New: 0.20 - 0.35 mm. Max wear limit: +0.10 to +0.15 mm over new (e.g., 0.35 - 0.50 mm total).
Rotor Shaft Run-outMaximum permissible run-out: 0.03 mm.
Bearing Shell ThicknessVisual inspection for scoring, pitting, or excessive material loss. Measurement against new dimensions if wear is suspected.
Turbine/Compressor Blade TipsVisual inspection for rubbing marks on casing, erosion, or cracks. No specific numerical limit, but any contact or significant damage requires replacement/repair.
Nozzle Ring OpeningVisual inspection for erosion, cracks, or excessive carbon build-up that restricts gas flow. Measurement of opening area against new specifications if performance is degraded.

Ranges are typical for this design class. Always confirm against the manufacturer documentation for your serial number.

Critical spares

  • Complete bearing cartridge assembly (journal and thrust bearings).
  • Oil seals and O-ring sets for bearing housing.
  • Gasket sets for casing joints (gas inlet/outlet, air outlet).
  • Lubricating oil filters (if external to engine system).
  • Nozzle ring (especially if operating in challenging fuel conditions or if previous damage history).
  • Compressor/Turbine cleaning agents and washing nozzles.
  • Special tools for dismantling and assembly (e.g., rotor lifting tools, bearing pullers).

Safety

  • High temperatures: Exhaust gas casing and turbine components operate at extremely high temperatures; severe burn hazard.
  • High rotational speeds: Rotor operates at tens of thousands of RPM; risk of catastrophic failure (rotor burst) if severely imbalanced or damaged.
  • High pressure: Compressor discharge air and exhaust gas are under high pressure; potential for injury during maintenance if not depressurized.
  • Hot oil: Lubricating oil can be hot and under pressure; risk of burns and slips.
  • Heavy lifting: Turbocharger components (e.g., casings, rotor assembly) are heavy and require proper lifting gear and procedures during maintenance.

Class survey

Class surveyors typically focus on: 1. Review of maintenance records, running hours, and spare parts certificates. 2. Visual inspection for external leaks, damage, and security of mounting. 3. Verification of operational parameters (RPM, boost pressure, exhaust temperatures) against design values. 4. If due for an overhaul or if performance issues are reported, an opening inspection of the compressor and turbine sides may be required to assess fouling, wear, and damage. 5. Confirmation of overspeed trip functionality and alarm settings. 6. Integrity of the lubricating oil supply and drainage system.

Estimated lifetime: The main structural components (casings) can last for the lifetime of the engine (100,000+ hours) with proper maintenance. The rotating assembly and wear parts typically undergo a major overhaul every 32,000 - 48,000 running hours, where critical components are replaced or refurbished to extend the overall service life.

Need this part?

Request a quote for this model.

Free of charge — send us your request for Hitachi equipment. Our team checks it and replies by e-mail.

For marine equipment hardly any maker or authorised dealer will name a price while the vessel is unknown. With the vessel details, availability and price can be settled faster; without them we may have to ask first, which costs a few days. If you are not allowed to name the vessel, a photo of the rating plate is enough — attach it below or send it as a reply to our confirmation e-mail.

Your contact details are not published. No account required.
Related models

Also in Turbocharger.

Other models of the same equipment type, Hitachi first.

By manufacturer ABBMAN Energy SolutionsIHIMitsubishiABB Turbocharging / AccelleronKawasakiPBSTCummins Holset TurbochargersNapierMAN ES TurbochargingMitsubishi METGarrett Motion MarineVolvo Pentaengine.od / Other TurbochargersKBB TurboAll manufacturersSpare parts by equipmentNew here? Create a free account Can't read the plate? Try the nameplate scanner More like HT-C HT-71C
More than the data sheet shows

We answer by e-mail, never with an automatic reply.

Tell us what you need for this Hitachi HT-C HT-71C — a part, a service call, a second opinion. Are you Hitachi? Claim this brand page.

Service engineer? Write the day report for this HT-C HT-71C in OceanSphere Work — photos, hours and parts, as a PDF for the owner. Try it free for 14 days →

Frequently asked

Questions that come up with this equipment.

Is this model's data free?

Yes. Specifications, documents and service notes for this model are readable without an account. An account adds saved searches and requests, nothing is taken away.

Can you find a part for this exact model?

Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.

The specifications look wrong — what now?

Send us the nameplate or the correct value. We check it against the manufacturer datasheet or class-society record and update the page.