A direct online starter connects a motor straight to full supply voltage in one step, giving full starting torque immediately but drawing five to eight times full-load current, which is why it is only used where the supply and the driven load can absorb that inrush.
The 100 models with the most complete data of 111 in Direct Online Starter (DOL). Every row links to full specifications, documents and service notes.
All 4 manufacturers with models of Direct Online Starter (DOL). Every name opens a search across the full library.
The other equipment types in this category.
A DOL starter is the simplest motor control arrangement on the ship: a contactor and overload relay, nothing more. Close the contactor and the motor sees full line voltage immediately, developing full starting torque from the first instant, which suits loads that need torque right away such as small pumps and fans. The cost of that simplicity is the inrush current, typically five to eight times the motor's rated current for a second or two, which stresses the supply switchboard and can cause a visible voltage dip that affects other…
A DOL starter is the simplest motor control arrangement on the ship: a contactor and overload relay, nothing more. Close the contactor and the motor sees full line voltage immediately, developing full starting torque from the first instant, which suits loads that need torque right away such as small pumps and fans. The cost of that simplicity is the inrush current, typically five to eight times the motor's rated current for a second or two, which stresses the supply switchboard and can cause a visible voltage dip that affects other equipment on the same bus. Star-delta and soft starters exist precisely to avoid that inrush; DOL is chosen instead when the motor is small enough, relative to the generator capacity, that the dip is acceptable, or when the driven load genuinely needs full torque at zero speed.
An electromagnetically operated switch that connects the three motor phases to the supply, sized by current rating and utilization category for motor duty.
A protective device that trips the contactor if motor current stays above the set threshold for longer than its time-current curve allows, protecting the winding from a stalled rotor or prolonged overload.
A fuse or motor circuit breaker upstream of the contactor that clears a fault current far faster than the overload relay is designed to.
Start and stop pushbuttons, a holding contact that latches the contactor closed after the start button is released, and any interlocks from the process, such as a low-level cutout on a pump.
Motor starters for essential services fall under class electrical installation rules covering protection coordination, short-circuit withstand and the requirement for independent overload and short-circuit protection on each motor circuit. Where the motor drives an essential auxiliary, class rules typically require the starter circuit to be arranged so a fault on one motor circuit does not disable protection on others sharing the same switchboard section. There is no IMO instrument specific to starter type; the governing requirements come through the classification society's electrical installation rules.
| Fault | Cause | Consequence |
|---|---|---|
| Contactor contact welding | Repeated starts under high inrush, or attempting to interrupt a fault current | Motor cannot be stopped from the control circuit, contactor must be replaced |
| Nuisance overload tripping | Overload relay set below actual full-load current, or a genuinely tight bearing | Unplanned stoppage of the driven pump or fan |
| Failure to trip on locked rotor | Overload relay incorrectly sized or bypassed | Winding burnout on a stalled motor |
| Chattering contactor | Low control voltage or a loose control circuit connection | Contact erosion and eventual failure to hold the motor running |
Before blaming the motor for a trip, check whether the overload relay is actually set to the motor's nameplate current; a mismatched relay setting causes more nuisance trips than any winding fault.
Tell us the manufacturer, the model and what you need — a part, a service call, a second opinion. Our desk asks the right suppliers from a network of over 114,000 companies and comes back with a quote or a sourcing plan, not a search page.
Yes. Every model page, every guide and every datasheet for this type is readable without an account. An account adds saved searches and requests, nothing is taken away.
Send us the nameplate. We identify it by hand, add it to the library, and if you need a part or a service, the request is already on our desk.
Yes. Tell us the manufacturer, the model and what you need — our desk asks the right suppliers from a network of over 114,000 companies and comes back with a quote or a sourcing plan.