Rockwell/AB Marine

PowerFlex 4M 0.4kW 440V Marine

Rockwell/AB Marine PowerFlex 4M 0.4kW 440V Marine is identified in the source list as a direct-on-line motor starter. It is installed in a motor-control center, starter panel or local enclosure close to the electrical distribution and driven machinery. Its purpose is to connect a motor directly to the supply under command while providing the required contactor, overload and interlock functions. The source record provides no additional model-specific operating figure beyond the listed designation and category. Main contactor, overload protection, control relays, auxiliary contacts and local or remote start-stop circuits form the starter assembly. The exact model designation distinguishes motor rating, voltage class and protection functions from neighboring starters; refer to the manufacturer documentation for the exact figure.

Components & Design

Component data being added…

Technical Data

motor power kw 0.4
breaking capacity ka 50
protection class IP55

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Main contactor wear or coil failure caused by repeated switching or overheating, resulting in chatter, failure to close or welded contacts
Loose power terminals caused by thermal cycling or poor connection, resulting in local overheating, phase imbalance or burnt insulation
Control-relay, auxiliary-contact or coil failure caused by wear or voltage problems, resulting in failure to start, stop or maintain an interlock
Overload or current-sensing error caused by incorrect setting or device failure, resulting in nuisance trips or inadequate motor protection
Enclosure contamination caused by dust, salt or moisture, resulting in corrosion, tracking or reduced insulation resistance

Service & Maintenance

Inspect power and control terminals, contactors, overload devices, control relays and enclosure condition with the circuit safely isolated. Review trip history and compare motor current between phases when appropriate. Function-test start, stop, emergency stop and process interlocks according to vessel procedure. Check contact condition, coils and signs of overheating. Verify overload settings against the actual motor data after replacement. Refer to the manufacturer documentation for the exact figure for current settings, trip characteristics and electrical test values.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Keep contactor coils or complete contactors, auxiliary contacts, overload modules, fuses, control relays and manufacturer-recommended replacement starters. Critical motors may justify a complete spare starter. Preserve setting records for adjustable protection devices.
Equipment Model #92640 · ✓ still in production