Gas Detection

Single Gas Detector

A single gas detector monitors one hazard only, most often oxygen or one specific toxic gas, and unlike a multi-gas unit it cannot by itself clear a space for enclosed space entry under SOLAS and ISM procedures.

71models 7manufacturers
Models

Models in this type.

The 71 models with the most complete data of 71 in Single Gas Detector. Every row links to full specifications, documents and service notes.

Honeywell / BW TechnologiesBW Ultra CO only-B Honeywell / BW TechnologiesBW Ultra H2S only-B Honeywell / BW TechnologiesBW Ultra LEL only-B Honeywell / BW TechnologiesBW Ultra O2 only-B Honeywell / BW TechnologiesBW Ultra VOC only-B Honeywell / BW TechnologiesHoneywell BW Clip4 CO Honeywell / BW TechnologiesHoneywell BW Clip4 H2S Honeywell / BW TechnologiesHoneywell BW Clip4 O2 Honeywell / BW TechnologiesHoneywell BW Clip4 SO2 Honeywell / BW TechnologiesHoneywell BW Solo CO Honeywell / BW TechnologiesHoneywell BW Solo H2S Honeywell / BW TechnologiesHoneywell BW Solo O2 Honeywell / BW TechnologiesHoneywell BW Solo SO2 Honeywell / BW TechnologiesHoneywell BW Ultra CO Honeywell / BW TechnologiesHoneywell BW Ultra H2S Honeywell / BW TechnologiesHoneywell BW Ultra O2 Honeywell / BW TechnologiesHoneywell BW Ultra SO2 MSA SafetyALTAIR 5X CO only-B MSA SafetyALTAIR 5X H2S only-B MSA SafetyALTAIR 5X LEL only-B MSA SafetyALTAIR 5X O2 only-B MSA SafetyALTAIR 5X VOC only-B MSA SafetyMSA ALTAIR 2X CO MSA SafetyMSA ALTAIR 2X H2S MSA SafetyMSA ALTAIR 2X O2 MSA SafetyMSA ALTAIR 4X CO MSA SafetyMSA ALTAIR 4X H2S MSA SafetyMSA ALTAIR 4X O2 MSA SafetyMSA ALTAIR 5X CO MSA SafetyMSA ALTAIR 5X H2S MSA SafetyMSA ALTAIR 5X O2 hanlaimsDräger Pac 3500 hanlaimsDräger Pac 3500 CO hanlaimsDräger Pac 3500 CO 1) hanlaimsDräger Pac 3500 H2S hanlaimsDräger Pac 3500 H2S 1) hanlaimsDräger Pac 3500 O2 hanlaimsDräger Pac 3500 O2 1) hanlaimsDräger Pac 5500 CO hanlaimsDräger Pac 5500 CO 1) hanlaimsDräger Pac 5500 H2S hanlaimsDräger Pac 5500 H2S 1) hanlaimsDräger Pac 5500 O2 hanlaimsDräger Pac 5500 O2 1) Riken KeikiGX-3R Pro CO only-B Riken KeikiGX-3R Pro H2S only-B Riken KeikiGX-3R Pro LEL only-B Riken KeikiGX-3R Pro O2 only-B Riken KeikiGX-3R Pro VOC only-B Riken KeikiRiken SD-1 CO Riken KeikiRiken SD-1 H2S Riken KeikiRiken SD-1 LEL Riken KeikiRiken SD-1 O2 Industrial ScientificISC GasBadge Pro CO Industrial ScientificISC GasBadge Pro H2S Industrial ScientificISC GasBadge Pro O2 Industrial ScientificVentis Pro5 CO only-B Industrial ScientificVentis Pro5 H2S only-B Industrial ScientificVentis Pro5 LEL only-B Industrial ScientificVentis Pro5 O2 only-B Industrial ScientificVentis Pro5 VOC only-B CrowconGas-Pro TK CO only-B CrowconGas-Pro TK H2S only-B CrowconGas-Pro TK LEL only-B CrowconGas-Pro TK O2 only-B CrowconGas-Pro TK VOC only-B DrägerX-am 8000 CO only-B DrägerX-am 8000 H2S only-B DrägerX-am 8000 LEL only-B DrägerX-am 8000 O2 only-B DrägerX-am 8000 VOC only-B
By manufacturer

Manufacturers.

All 7 manufacturers with models of Single Gas Detector. Every name opens a search across the full library.

Related types

Also in Gas Detection.

The other equipment types in this category.

Fixed Gas Detection SystemFixed Gas DetectorGas Detection Control PanelOpen Path Gas DetectorPortable Multi-Gas Detector
Knowledge

What to check on a Single Gas Detector.

A single gas detector is a small personal instrument built to monitor one hazard, or occasionally two, continuously while worn by an individual — commonly oxygen alone, or one toxic gas such as hydrogen sulphide or carbon monoxide. It differs from a multi-gas detector, which covers oxygen, flammability and one or two toxic gases together and is what enclosed space entry procedures actually require, and from a fixed installed detector wired into the ship's alarm system covering a whole compartment rather than one person.

What sets a single gas detector apart

A single gas detector is a small personal instrument built to monitor one hazard, or occasionally two, continuously while worn by an individual — commonly oxygen alone, or one toxic gas such as hydrogen sulphide or carbon monoxide. It differs from a multi-gas detector, which covers oxygen, flammability and one or two toxic gases together and is what enclosed space entry procedures actually require, and from a fixed installed detector wired into the ship's alarm system covering a whole compartment rather than one person.

Single gas detector front view
Front view of a portable single gas detector showing the digital display, alarm indicator, power/mode button, diffusion sample inlet and belt clip.

Main components

Sensor

An electrochemical cell for oxygen or a specific toxic gas, a catalytic bead sensor for flammable gas, or an infrared sensor where catalytic poisoning is a concern; the sensor is the part with a finite service life, typically one to two years for an electrochemical cell.

Sampling method

Most single gas detectors are diffusion type, relying on ambient gas reaching the sensor directly, which suits personal wear; pumped versions draw a sample through a hose and suit checking a space before entry.

Alarm and display

Audible, visual and vibration alarms trigger at a preset threshold, with a simple display showing the current reading; the alarm has to be noticeable over engine room noise or inside a confined space.

Battery and calibration port

A rechargeable or replaceable battery sized against typical watch length, and a port for connecting a calibration gas cylinder during routine checks.

Selection and sizing

  • The gas chosen has to match the actual hazard for the task — oxygen depletion for a general enclosed space, hydrogen sulphide for sewage or certain ballast and cargo tanks, carbon monoxide near exhaust or combustion equipment.
  • Diffusion detectors for personal wear during work inside a space; pumped sampling detectors for testing a space remotely before anyone enters it.
  • Battery runtime against the length of the task, and IP rating against wash-down or weather exposure in the area of use.

Regulations

IMO enclosed space entry guidance and SOLAS-linked safety management procedures require gas testing before entry into any enclosed space, and this testing is expected to cover oxygen, flammability and relevant toxic gases together, which a single gas detector cannot do on its own. Detectors require periodic bump testing against a certified test gas and full calibration on a schedule, with records kept under the ship's safety management system.

Typical faults

FaultCauseConsequence
Sensor poisoning or ageingElectrochemical cells have a finite life and degrade with exposure to certain gasesFalse or drifting readings without an obvious failure indication
Battery depletion mid-taskSkipped charge before a long jobLoss of continuous personal monitoring at the point it matters most
Calibration driftMissed calibration intervalUnder- or over-reading against the true gas concentration
Skipped bump testTime pressure before entryFalse confidence in a detector that may not respond correctly

What to look for in a supplier

  • Availability of sensor replacement and calibration service, on board or through a shore agent, matched to the ship's trading pattern.
  • Supply of certified bump-test gas cylinders compatible with the detector.
  • Robustness of the housing for engine room or tank environments, and battery life against typical watch length.

A single gas detector answers one question, not the full enclosed space check — treating it as a substitute for a proper multi-gas test before entry has cost lives, and the record of near misses is not short.

Search by manufacturer AFRISOWISKASwagelokAlfa Laval S.p.A.MAN Energy SolutionsWärtsiläEndress+HauserABB MarineAlfa LavalMacGregorNovenco MarineCarrier MarineSiemens MarineHeinen & HopmanDaikin Marine
Would you like to know more?

One request. A person answers within 24 hours on working days.

Tell us the manufacturer, the model and what you need — a part, a service call, a second opinion. Our desk asks the right suppliers from a network of over 114,000 companies and comes back with a quote or a sourcing plan, not a search page.

Frequently asked

Three things people ask first.

Is Single Gas Detector data free?

Yes. Every model page, every guide and every datasheet for this type is readable without an account. An account adds saved searches and requests, nothing is taken away.

My model is missing — what now?

Send us the nameplate. We identify it by hand, add it to the library, and if you need a part or a service, the request is already on our desk.

Can you source a Single Gas Detector part?

Yes. Tell us the manufacturer, the model and what you need — our desk asks the right suppliers from a network of over 114,000 companies and comes back with a quote or a sourcing plan.