A hydrophore set turns the intermittent output of a fresh water pump into steady mains-like pressure at every tap, using a pressure vessel with an air or bladder cushion to smooth out pump cycling - get the tank size wrong and the pump short-cycles itself to an early failure.

40models
RWO/Veolia
Knowledge

What to check on a Hydrophore / Pressure Set.

40 models from RWO/Veolia in Hydrophore / Pressure Set. Below: the full model list.

What distinguishes a hydrophore from a simple pressure pump

A hydrophore, or pressure/hydrophore set, is not just a pump - it is a pump paired with a pressure vessel that stores a cushion of compressed air (or, in bladder-type designs, air separated from the water by a rubber diaphragm) so that small draw-offs at taps are supplied from the tank's stored pressure without the pump starting every time. The pump only starts when tank pressure falls to a set low point and stops again at a set high point, giving cycling that protects the pump from constant short starts and gives smoother pressure at the tap than a pump running directly against demand.

Hydrophore pressure set schematic
Flow schematic of a hydrophore pressure set showing the tank, pump, non-return valve, the pressure vessel with its air cushion over the water charge, the pressure switch controlling the pump, and the outlet to distribution.
Read the full guide

Main components

Pressure vessel

Air-over-water tanks need periodic air recharging as the air cushion slowly absorbs into the water over time; bladder-type tanks keep air and water permanently separated and need no recharging but the bladder itself can fail.

Pump set

Usually duty/standby centrifugal pumps so one unit can be serviced without losing water pressure, controlled by pressure switches or a variable speed drive.

Pressure switches / control panel

Set the cut-in and cut-out pressure points, and on more modern sets provide alternation between duty and standby pump and alarm on low pressure or pump fault.

Non-return and isolating valves

Prevent backflow into the pump when it is stopped and allow individual pumps or the tank itself to be isolated for maintenance without draining the whole system.

Selection and sizing

  • Tank volume matched to expected peak demand and acceptable cycling frequency - too small a tank causes the pump to short-cycle and wear out early, too large adds weight and space for no operational benefit.
  • Pump duty point (flow and head) matched to the highest fixture in the distribution system plus the pressure needed at the tap, not just the average demand.
  • Duty/standby arrangement sized so either pump alone can meet reasonable demand, since running both together as normal practice defeats the redundancy.
  • Materials in contact with potable water suited to drinking water service, not general service fittings.

Regulations and class

Potable water systems fall under the classification society's rules for domestic systems and under flag state or port state health requirements for drinking water quality, which bear on materials and on cross-connection prevention rather than on the hydrophore mechanism itself. Pressure vessels in the set are subject to the same pressure equipment testing requirements as other vessels of similar design pressure, including periodic inspection where the vessel construction and class rules require it.

Typical faults

FaultCauseConsequence
Pump short-cycles, starting and stopping rapidlyLost air cushion in an air-over-water tank, or a burst bladder in a bladder tankRapid pump wear and premature motor or seal failure
Falling pressure at taps despite pump runningWorn pump impeller, clogged strainer, or a leak somewhere in the distribution systemPoor pressure throughout accommodation, complaints from crew
Standby pump never startsFailed alternation relay, stuck duty selectorNo redundancy if the duty pump fails - discovered only when it does
Waterlogged tank (no air cushion at all)Air recharge system failure or blocked air line on an air-over-water designPump cycles almost continuously, tank provides no buffering

What to look for in a supplier

  • Tank type (air-over-water versus bladder) matched to the maintenance regime the crew can actually sustain.
  • Pump curve data matched to the vessel's actual distribution system head loss, not a generic sizing chart.
  • Materials certified suitable for potable water contact.
  • Control panel compatible with existing alarm and monitoring systems if the set is a replacement rather than a new installation.

Count pump starts per hour, not just tank pressure, when troubleshooting a hydrophore set - a healthy-looking pressure gauge can still sit on top of a waterlogged tank that is cycling the pump to an early death.

Models

Models in this type.

The best-documented model of each manufacturer first, then the next — 40 of 40 models in Hydrophore / Pressure Set. Every row links to full specifications, documents and service notes.

Showing only RWO/Veolia. Show all manufacturers
RWO/VeoliaHydrophore 10m3h 3bar Marine RWO/VeoliaHydrophore 10m3h 4bar Marine RWO/VeoliaHydrophore 10m3h 5bar Marine RWO/VeoliaHydrophore 10m3h 6bar Marine RWO/VeoliaHydrophore 15m3h 3bar Marine RWO/VeoliaHydrophore 15m3h 4bar Marine RWO/VeoliaHydrophore 15m3h 5bar Marine RWO/VeoliaHydrophore 15m3h 6bar Marine RWO/VeoliaHydrophore 1m3h 3bar Marine RWO/VeoliaHydrophore 1m3h 4bar Marine RWO/VeoliaHydrophore 1m3h 5bar Marine RWO/VeoliaHydrophore 1m3h 6bar Marine RWO/VeoliaHydrophore 20m3h 3bar Marine RWO/VeoliaHydrophore 20m3h 4bar Marine RWO/VeoliaHydrophore 20m3h 5bar Marine RWO/VeoliaHydrophore 20m3h 6bar Marine RWO/VeoliaHydrophore 2m3h 3bar Marine RWO/VeoliaHydrophore 2m3h 4bar Marine RWO/VeoliaHydrophore 2m3h 5bar Marine RWO/VeoliaHydrophore 2m3h 6bar Marine RWO/VeoliaHydrophore 30m3h 3bar Marine RWO/VeoliaHydrophore 30m3h 4bar Marine RWO/VeoliaHydrophore 30m3h 5bar Marine RWO/VeoliaHydrophore 30m3h 6bar Marine RWO/VeoliaHydrophore 3m3h 3bar Marine RWO/VeoliaHydrophore 3m3h 4bar Marine RWO/VeoliaHydrophore 3m3h 5bar Marine RWO/VeoliaHydrophore 3m3h 6bar Marine RWO/VeoliaHydrophore 50m3h 3bar Marine RWO/VeoliaHydrophore 50m3h 4bar Marine RWO/VeoliaHydrophore 50m3h 5bar Marine RWO/VeoliaHydrophore 50m3h 6bar Marine RWO/VeoliaHydrophore 5m3h 3bar Marine RWO/VeoliaHydrophore 5m3h 4bar Marine RWO/VeoliaHydrophore 5m3h 5bar Marine RWO/VeoliaHydrophore 5m3h 6bar Marine RWO/VeoliaHydrophore 8m3h 3bar Marine RWO/VeoliaHydrophore 8m3h 4bar Marine RWO/VeoliaHydrophore 8m3h 5bar Marine RWO/VeoliaHydrophore 8m3h 6bar Marine
40 models
By manufacturer

Manufacturers.

All 11 manufacturers with models of Hydrophore / Pressure Set. Names with a manufacturer page open it; the others open a search across the full library.

All manufacturers
Related types

Also in Potable Water System.

The other equipment types in this category.

Hot Water CalorifierHydrophore UnitPotable Water Treatment SystemUV Disinfection Unit
Would you like to know more?

One request. A person reads it and replies by e-mail.

Tell us the manufacturer, the model and what you need — a part, a service call, a second opinion. A person reads every request and replies by e-mail.

No details at hand? A photo of the rating plate or the part is enough — simply attach it to the request.

Frequently asked

Three things people ask first.

Is Hydrophore / Pressure Set data free?

Yes. Every model page, every guide and every datasheet for this type is readable without an account. An account adds saved searches and requests, nothing is taken away.

My model is missing — what now?

Send us the nameplate. We identify it by hand, add it to the library, and if you need a part or a service, the request is already on our desk.

Can you source a Hydrophore / Pressure Set part?

Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.