OceanSphereFree accountLog inDEENPL
OceanSphereENGINES
Library› Cargo› Cargo Level & Temperature Gauging› Float Level Switch
Cargo Level & Temperature Gauging

Float Level Switch

A float level switch gives a single discrete signal — high, low or a fixed intermediate point — rather than a continuous reading, which is why it is fitted as an independent high-level alarm even on tanks that already carry a radar or servo gauge.

1model
Panasia
Knowledge

What to check on a Float Level Switch.

1 models from Panasia in Float Level Switch. Below: the full model list.

What Makes This Type Different

A float level switch is a point-level device, not a continuous gauge: a float rides on the liquid surface, and when it reaches a fixed position it trips a magnetic reed switch or a mechanical microswitch through a sealed tube or a hinged arm. It gives one bit of information — liquid present or absent at that height — rather than a full column reading. That simplicity is the reason it survives as an independent overfill or low-level alarm even on tanks already fitted with a servo or radar gauge: the switch has no shared electronics with the primary instrument, so a fault in one system does not blind the other.

Float level switch arrangement
Cross-section of a cargo tank showing a float level switch on a guide tube, with high- and low-level reed switch points, a switch housing at the tank top and a cable run to the alarm panel.
Read the full guide

Main Components

Float

Sealed stainless steel or plastic float sized for the specific gravity of the cargo it will see — a float calibrated for seawater will sit differently, or not trip at all, in a lighter cargo such as gasoline.

Guide Tube or Stem

Keeps the float travelling in a straight line so it cannot jam against the tank wall or an internal structure as the level rises and falls.

Switch Mechanism

Reed switch actuated by a magnet in the float, with no mechanical linkage through the tank wall, or a mechanical microswitch on a pivot arm; the reed type is preferred in cargo tanks because it needs no moving seal at the pressure boundary.

Housing and Cable Entry

Pressure-rated housing at the tank penetration, with the cable gland certified for the tank's hazardous area classification.

Selection and Sizing

  • Specific gravity range: the float must be matched to the lightest and heaviest cargo the tank will carry, or it will under- or over-read the trip point.
  • Trip point: fixed at the design stage — high-high alarm, high alarm, low alarm — and not something adjusted casually once installed.
  • Pressure and temperature rating: must match the tank's design conditions, especially on gas carriers or heated cargo tanks.
  • Material compatibility: stainless grade or elastomer seals suited to the cargo chemistry, checked against the cargo's compatibility list.

Regulations and Class

On oil and chemical tankers, an independent high-level alarm separate from the main gauging system is required under overfill protection provisions linked to MARPOL Annex I/II and reinforced by class rules and the ship's cargo operations manual; float switches are one accepted means of providing that independent signal. Class surveys check that the alarm actually trips at the set point during a functional test, not just that the wiring reads continuity.

Typical Faults

  • Float stuck in guide tube due to wax or sludge build-up — alarm never trips even though the tank is overfilling.
  • Reed switch degraded by repeated cycling — intermittent or false alarms that crews learn to ignore, which defeats the purpose of the alarm.
  • Float punctured or waterlogged — loss of buoyancy, switch trips late or not at all.
  • Wrong float fitted after a spares mix-up — trip point shifts because the float's specific gravity no longer matches the cargo.
  • Cable gland leaking at the tank penetration — moisture ingress into the switch housing, corrosion of contacts.

What to Look for in a Supplier

  • Float material and specific gravity rating stated for the actual cargo range, not a generic water-service default.
  • Certification for the tank's hazardous area zone and gas group.
  • Documented trip-point repeatability, since this is a safety alarm, not a rough indication.

Test the float switch by physically raising the float during tank cleaning, not only by checking continuity at the terminal box — a switch that reads correctly on the bench can still be jammed by sludge in service.

Models

Models in this type.

The best-documented model of each manufacturer first, then the next — 1 of 1 models in Float Level Switch. Every row links to full specifications, documents and service notes.

Showing only Panasia. Show all manufacturers
1 model
By manufacturer

Manufacturers.

All 15 manufacturers with models of Float Level Switch. Names with a manufacturer page open it; the others open a search across the full library.

All manufacturers
Related types

Also in Cargo Level & Temperature Gauging.

The other equipment types in this category.

Pressure/DP TransmitterRadar Level GaugeServo Level GaugeTank Sounding SystemTemperature SensorUTI EquipmentUltrasonic Level Gauge
Would you like to know more?

One request. A person reads it and replies by e-mail.

Tell us the manufacturer, the model and what you need — a part, a service call, a second opinion. A person reads every request and replies by e-mail.

No details at hand? A photo of the rating plate or the part is enough — simply attach it to the request.

Frequently asked

Three things people ask first.

Is Float Level Switch data free?

Yes. Every model page, every guide and every datasheet for this type is readable without an account. An account adds saved searches and requests, nothing is taken away.

My model is missing — what now?

Send us the nameplate. We identify it by hand, add it to the library, and if you need a part or a service, the request is already on our desk.

Can you source a Float Level Switch part?

Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.