A variable frequency drive controls a motor's speed by synthesising a variable-frequency AC waveform electronically, instead of throttling the driven equipment mechanically, which cuts the power a pump or fan draws roughly with the cube of the speed reduction rather than wasting it across a valve or damper.
1 models from fike in Variable Frequency Drive (VFD) / Frequency Converter. Below: the full model list.
A variable frequency drive rectifies incoming AC supply to DC, smooths it on a DC bus, then uses an inverter stage to synthesise a new AC waveform at whatever frequency and voltage the motor needs, so motor speed follows the drive's output frequency instead of being fixed to the supply frequency. That sets it apart from a soft-starter, which only ramps voltage during starting while the motor still runs at line frequency once started, and from mechanical speed control by valve, damper or fluid coupling, which wastes the excess energy as heat or pressure loss rather than avoiding drawing it in the first place.
Sizing starts from motor power and voltage, but the load type matters as much as the number on the nameplate: a centrifugal pump or fan is a variable-torque load that needs relatively little torque at low speed, while a winch or thruster is a constant or high-torque load at low speed and needs a drive with a correspondingly higher overload margin. Cable length between drive and motor decides whether an output filter is needed to protect motor insulation from voltage reflection. Where several drives share one switchboard busbar, the combined harmonic distortion may exceed what the installation can tolerate, requiring input filtering or a multi-pulse rectifier on the larger units.
Class rules set a limit on harmonic distortion at the switchboard, which can force filtering when several drives are installed on the same bus. A drive feeding one of a duty/standby pair of essential pumps or fans does not remove the redundancy requirement — the standby unit still has to be independently available if the drive itself fails. EMC performance matters on a steel hull carrying sensitive navigation and communication electronics close to the switching noise a drive generates.
Match the drive's overload rating to how the load actually behaves at low speed — a drive sized only for nameplate motor power can trip repeatedly on a thruster or winch that needs high torque near zero speed.

The best-documented model of each manufacturer first, then the next — 1 of 1 models in Variable Frequency Drive (VFD) / Frequency Converter. Every row links to full specifications, documents and service notes.
All 76 manufacturers with models of Variable Frequency Drive (VFD) / Frequency Converter. Names with a manufacturer page open it; the others open a search across the full library.
All manufacturersThe other equipment types in this category.
Tell us the manufacturer, the model and what you need — a part, a service call, a second opinion. A person reads every request and replies by e-mail.
No details at hand? A photo of the rating plate or the part is enough — simply attach it to the request.
Yes. Every model page, every guide and every datasheet for this type is readable without an account. An account adds saved searches and requests, nothing is taken away.
Send us the nameplate. We identify it by hand, add it to the library, and if you need a part or a service, the request is already on our desk.
Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.