OceanSphere
Engines

Totally Enclosed Lifeboat (TELB)

medium 367 models total

A totally enclosed lifeboat carries its occupants inside a closed, water-resistant shell with seat belts and its own engine, and is normally self-righting. Its on-load release hook, not the boat itself, is the component with the worst accident record in the lifeboat fleet.

Read more — Totally Enclosed Lifeboat (TELB) explained

What sets this type apart

A totally enclosed lifeboat (TELB) differs from an open or partially enclosed lifeboat by fully closing the occupants inside a rigid, buoyant shell that protects them from weather and sea spray, and, for the fire-protected variant, from radiant heat during a launch past a burning ship's side. Occupants sit in fixed seats with lap or full harness belts, since a self-righting hull can genuinely roll through 360 degrees in a heavy sea and come back upright with everyone still inside. Tankers and gas carriers typically require the fire-protected version, rated to survive a period of exposure to an external fire while people remain inside.

Totally enclosed lifeboat arrangement
Side view of a totally enclosed lifeboat showing the closed canopy shell, the on-load release hook connected to the davit falls, the entry hatch, the painter at the bow and the engine, propeller and rudder at the stern.

Main components

Hull and canopy

A one-piece or bonded fibre-reinforced plastic hull provides buoyancy and structural strength; the fire-protected variant adds an external water-spray or insulated skin so the shell can pass through burning fuel on the water without the interior becoming unsurvivable for the rated exposure time.

Engine and propulsion

A compression-ignition engine, often air-cooled or with a water-cooling system that keeps working during brief full immersion, drives a propeller through a simple gearbox. The engine must start and run reliably after long idle periods, which makes fuel and battery maintenance one of the more neglected items on the annual inspection.

On-load release hook and hydrostatic interlock

The on-load release system lets the crew release the boat from the falls while still waterborne under load, avoiding a fall that damages the boat or injures occupants. This mechanism has caused a disproportionate number of serious and fatal accidents worldwide, usually from accidental release during lowering or from crew misunderstanding the interlock meant to prevent release before the boat is waterborne.

Davit, falls and winch

Gravity davits lower the boat under brake control; the falls and winch brake must hold the boat's full loaded weight reliably at any point during lowering, and the brake is one of the items proof-loaded at survey.

Painter and release line

A painter line lets the boat be held clear of the ship's side or towed away after release, and on some arrangements includes a weak link intended to part before the falls, rather than the crew, take the strain if the boat is not properly released.

Selection and sizing

Capacity is set by the certified maximum number of persons the hull, seating and davit system can carry, not by internal volume alone; every seat has a rated occupant mass, and loading beyond the certified number is not permitted regardless of available space inside. Davit SWL and boat weight fully equipped and manned must match, with margin built into the davit and winch brake rating.

Regulations and class

Totally enclosed lifeboats fall under the SOLAS Life-Saving Appliances (LSA) Code, and after a string of on-load release hook accidents, IMO introduced amendments requiring on-load release gear on existing ships to be assessed and, where it does not meet the updated design standard, replaced. Annual inspection, five-yearly load testing of falls and davit, and periodic servicing of the release gear by an approved service provider are separate class and flag requirements, and a lifeboat found without current servicing documentation is routinely detained.

Typical faults

  • Release hook misadjustment or wear - accidental release during lowering, or failure to release once waterborne; the leading cause of serious lifeboat accidents.
  • Engine failing to start after prolonged idle - stale fuel, flat or sulphated battery, seized cooling water pump.
  • Corroded or seized falls and blocks - uneven lowering, one end dropping faster than the other.
  • Painter or weak link fitted incorrectly - boat not held clear after release, or premature parting under normal handling.
  • Seat belt and seating hardware deterioration - reduced protection in a genuine capsize or heavy impact launch.

What to look for in a supplier

  • An approved service provider certificate specific to the release gear maker and model fitted, not a general lifeboat service claim.
  • Documented compliance path for the on-load release gear amendments where the ship's existing hook predates the updated standard.
  • Availability of hull, canopy and seating spares matched to the boat's actual model year, since hook and davit interfaces have changed across production runs.

Treat any unexplained slack, stiffness or inconsistent feel in the release hook operating lever as a reason to stop and call the service provider, not as something to work around during the next drill.

16 manufacturers · 367 models

Misea Machinery

22 ✓ 22 verified
Misea Machinery TEL-X50C
TEL-X50C ✓ verified
Application
Conventional Totally Enclosed Lifeboat
Common Failures & Inspection Points
  • Area: Weekly engine system inspection and functional testing per SOLAS requirements
    Check: Weekly engine system inspection and functional testing per SOLAS requirements
  • Area: Monthly lifeboat release mechanism testing and load line verification
    Check: Monthly lifeboat release mechanism testing and load line verification
  • Area: Quarterly visual inspection of airtight seals, hatches, and hull integrity for corrosion or damage
    Check: Quarterly visual inspection of airtight seals, hatches, and hull integrity for corrosion or damage
  • Area: Annual compressed air supply system functionality test (minimum 10 minutes duration coverage)
    Check: Annual compressed air supply system functionality test (minimum 10 minutes duration coverage)
  • Area: Annual fire-resistant material inspection (capability to withstand 1,200°C for 8 minutes)
    Check: Annual fire-resistant material inspection (capability to withstand 1,200°C for 8 minutes)
  • Area: Five-year comprehensive third-party classification survey and recertification
    Check: Five-year comprehensive third-party classification survey and recertification
  • Area: Annual ventilation system capacity verification (minimum 5 m³/hour per person for 24 hours)
    Check: Annual ventilation system capacity verification (minimum 5 m³/hour per person for 24 hours)
  • Area: Biennial self-righting mechanism test and hydraulic system performance verification
    Check: Biennial self-righting mechanism test and hydraulic system performance verification

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

Misea Machinery TEL-X50F
TEL-X50F ✓ verified
Application
Freefall Variant Totally Enclosed Lifeboat
Common Failures & Inspection Points
  • Area: Weekly engine system inspection and functional testing per SOLAS requirements
    Check: Weekly engine system inspection and functional testing per SOLAS requirements
  • Area: Monthly lifeboat release mechanism testing and load line verification
    Check: Monthly lifeboat release mechanism testing and load line verification
  • Area: Quarterly visual inspection of airtight seals, hatches, and hull integrity for corrosion or damage
    Check: Quarterly visual inspection of airtight seals, hatches, and hull integrity for corrosion or damage
  • Area: Annual compressed air supply system functionality test (minimum 10 minutes duration coverage)
    Check: Annual compressed air supply system functionality test (minimum 10 minutes duration coverage)
  • Area: Annual fire-resistant material inspection (capability to withstand 1,200°C for 8 minutes)
    Check: Annual fire-resistant material inspection (capability to withstand 1,200°C for 8 minutes)
  • Area: Five-year comprehensive third-party classification survey and recertification
    Check: Five-year comprehensive third-party classification survey and recertification
  • Area: Annual ventilation system capacity verification (minimum 5 m³/hour per person for 24 hours)
    Check: Annual ventilation system capacity verification (minimum 5 m³/hour per person for 24 hours)
  • Area: Biennial self-righting mechanism test and hydraulic system performance verification
    Check: Biennial self-righting mechanism test and hydraulic system performance verification

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

Misea Machinery TEL-50C
TEL-50C ✓ verified
Application
Conventional Totally Enclosed Lifeboat
Common Failures & Inspection Points
  • Area: Weekly engine system inspection and functional testing per SOLAS requirements
    Check: Weekly engine system inspection and functional testing per SOLAS requirements
  • Area: Monthly lifeboat release mechanism testing and load line verification
    Check: Monthly lifeboat release mechanism testing and load line verification
  • Area: Quarterly visual inspection of airtight seals, hatches, and hull integrity for corrosion or damage
    Check: Quarterly visual inspection of airtight seals, hatches, and hull integrity for corrosion or damage
  • Area: Annual compressed air supply system functionality test (minimum 10 minutes duration coverage)
    Check: Annual compressed air supply system functionality test (minimum 10 minutes duration coverage)
  • Area: Annual fire-resistant material inspection (capability to withstand 1,200°C for 8 minutes)
    Check: Annual fire-resistant material inspection (capability to withstand 1,200°C for 8 minutes)
  • Area: Five-year comprehensive third-party classification survey and recertification
    Check: Five-year comprehensive third-party classification survey and recertification
  • Area: Annual ventilation system capacity verification (minimum 5 m³/hour per person for 24 hours)
    Check: Annual ventilation system capacity verification (minimum 5 m³/hour per person for 24 hours)
  • Area: Biennial self-righting mechanism test and hydraulic system performance verification
    Check: Biennial self-righting mechanism test and hydraulic system performance verification

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

Misea Machinery TEL-50F
TEL-50F ✓ verified
Application
Freefall Variant Totally Enclosed Lifeboat
Common Failures & Inspection Points
  • Area: Weekly engine system inspection and functional testing per SOLAS requirements
    Check: Weekly engine system inspection and functional testing per SOLAS requirements
  • Area: Monthly lifeboat release mechanism testing and load line verification
    Check: Monthly lifeboat release mechanism testing and load line verification
  • Area: Quarterly visual inspection of airtight seals, hatches, and hull integrity for corrosion or damage
    Check: Quarterly visual inspection of airtight seals, hatches, and hull integrity for corrosion or damage
  • Area: Annual compressed air supply system functionality test (minimum 10 minutes duration coverage)
    Check: Annual compressed air supply system functionality test (minimum 10 minutes duration coverage)
  • Area: Annual fire-resistant material inspection (capability to withstand 1,200°C for 8 minutes)
    Check: Annual fire-resistant material inspection (capability to withstand 1,200°C for 8 minutes)
  • Area: Five-year comprehensive third-party classification survey and recertification
    Check: Five-year comprehensive third-party classification survey and recertification
  • Area: Annual ventilation system capacity verification (minimum 5 m³/hour per person for 24 hours)
    Check: Annual ventilation system capacity verification (minimum 5 m³/hour per person for 24 hours)
  • Area: Biennial self-righting mechanism test and hydraulic system performance verification
    Check: Biennial self-righting mechanism test and hydraulic system performance verification

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

Misea Machinery TEL-57C
TEL-57C ✓ verified
Application
Conventional Totally Enclosed Lifeboat
Common Failures & Inspection Points
  • Area: Weekly engine system inspection and functional testing per SOLAS requirements
    Check: Weekly engine system inspection and functional testing per SOLAS requirements
  • Area: Monthly lifeboat release mechanism testing and load line verification
    Check: Monthly lifeboat release mechanism testing and load line verification
  • Area: Quarterly visual inspection of airtight seals, hatches, and hull integrity for corrosion or damage
    Check: Quarterly visual inspection of airtight seals, hatches, and hull integrity for corrosion or damage
  • Area: Annual compressed air supply system functionality test (minimum 10 minutes duration coverage)
    Check: Annual compressed air supply system functionality test (minimum 10 minutes duration coverage)
  • Area: Annual fire-resistant material inspection (capability to withstand 1,200°C for 8 minutes)
    Check: Annual fire-resistant material inspection (capability to withstand 1,200°C for 8 minutes)
  • Area: Five-year comprehensive third-party classification survey and recertification
    Check: Five-year comprehensive third-party classification survey and recertification
  • Area: Annual ventilation system capacity verification (minimum 5 m³/hour per person for 24 hours)
    Check: Annual ventilation system capacity verification (minimum 5 m³/hour per person for 24 hours)
  • Area: Biennial self-righting mechanism test and hydraulic system performance verification
    Check: Biennial self-righting mechanism test and hydraulic system performance verification

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

Misea Machinery TEL-57F
TEL-57F ✓ verified
Application
Freefall Variant Totally Enclosed Lifeboat
Common Failures & Inspection Points
  • Area: Weekly engine system inspection and functional testing per SOLAS requirements
    Check: Weekly engine system inspection and functional testing per SOLAS requirements
  • Area: Monthly lifeboat release mechanism testing and load line verification
    Check: Monthly lifeboat release mechanism testing and load line verification
  • Area: Quarterly visual inspection of airtight seals, hatches, and hull integrity for corrosion or damage
    Check: Quarterly visual inspection of airtight seals, hatches, and hull integrity for corrosion or damage
  • Area: Annual compressed air supply system functionality test (minimum 10 minutes duration coverage)
    Check: Annual compressed air supply system functionality test (minimum 10 minutes duration coverage)
  • Area: Annual fire-resistant material inspection (capability to withstand 1,200°C for 8 minutes)
    Check: Annual fire-resistant material inspection (capability to withstand 1,200°C for 8 minutes)
  • Area: Five-year comprehensive third-party classification survey and recertification
    Check: Five-year comprehensive third-party classification survey and recertification
  • Area: Annual ventilation system capacity verification (minimum 5 m³/hour per person for 24 hours)
    Check: Annual ventilation system capacity verification (minimum 5 m³/hour per person for 24 hours)
  • Area: Biennial self-righting mechanism test and hydraulic system performance verification
    Check: Biennial self-righting mechanism test and hydraulic system performance verification

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

Misea Machinery TEL-65C
TEL-65C ✓ verified
Application
Conventional Totally Enclosed Lifeboat
Common Failures & Inspection Points
  • Area: Weekly engine system inspection and functional testing per SOLAS requirements
    Check: Weekly engine system inspection and functional testing per SOLAS requirements
  • Area: Monthly lifeboat release mechanism testing and load line verification
    Check: Monthly lifeboat release mechanism testing and load line verification
  • Area: Quarterly visual inspection of airtight seals, hatches, and hull integrity for corrosion or damage
    Check: Quarterly visual inspection of airtight seals, hatches, and hull integrity for corrosion or damage
  • Area: Annual compressed air supply system functionality test (minimum 10 minutes duration coverage)
    Check: Annual compressed air supply system functionality test (minimum 10 minutes duration coverage)
  • Area: Annual fire-resistant material inspection (capability to withstand 1,200°C for 8 minutes)
    Check: Annual fire-resistant material inspection (capability to withstand 1,200°C for 8 minutes)
  • Area: Five-year comprehensive third-party classification survey and recertification
    Check: Five-year comprehensive third-party classification survey and recertification
  • Area: Annual ventilation system capacity verification (minimum 5 m³/hour per person for 24 hours)
    Check: Annual ventilation system capacity verification (minimum 5 m³/hour per person for 24 hours)
  • Area: Biennial self-righting mechanism test and hydraulic system performance verification
    Check: Biennial self-righting mechanism test and hydraulic system performance verification

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

Misea Machinery TEL-65F
TEL-65F ✓ verified
Application
Freefall Variant Totally Enclosed Lifeboat
Common Failures & Inspection Points
  • Area: Weekly engine system inspection and functional testing per SOLAS requirements
    Check: Weekly engine system inspection and functional testing per SOLAS requirements
  • Area: Monthly lifeboat release mechanism testing and load line verification
    Check: Monthly lifeboat release mechanism testing and load line verification
  • Area: Quarterly visual inspection of airtight seals, hatches, and hull integrity for corrosion or damage
    Check: Quarterly visual inspection of airtight seals, hatches, and hull integrity for corrosion or damage
  • Area: Annual compressed air supply system functionality test (minimum 10 minutes duration coverage)
    Check: Annual compressed air supply system functionality test (minimum 10 minutes duration coverage)
  • Area: Annual fire-resistant material inspection (capability to withstand 1,200°C for 8 minutes)
    Check: Annual fire-resistant material inspection (capability to withstand 1,200°C for 8 minutes)
  • Area: Five-year comprehensive third-party classification survey and recertification
    Check: Five-year comprehensive third-party classification survey and recertification
  • Area: Annual ventilation system capacity verification (minimum 5 m³/hour per person for 24 hours)
    Check: Annual ventilation system capacity verification (minimum 5 m³/hour per person for 24 hours)
  • Area: Biennial self-righting mechanism test and hydraulic system performance verification
    Check: Biennial self-righting mechanism test and hydraulic system performance verification

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

Misea Machinery TEL-75C
TEL-75C ✓ verified
Application
Conventional Totally Enclosed Lifeboat
Common Failures & Inspection Points
  • Area: Weekly engine system inspection and functional testing per SOLAS requirements
    Check: Weekly engine system inspection and functional testing per SOLAS requirements
  • Area: Monthly lifeboat release mechanism testing and load line verification
    Check: Monthly lifeboat release mechanism testing and load line verification
  • Area: Quarterly visual inspection of airtight seals, hatches, and hull integrity for corrosion or damage
    Check: Quarterly visual inspection of airtight seals, hatches, and hull integrity for corrosion or damage
  • Area: Annual compressed air supply system functionality test (minimum 10 minutes duration coverage)
    Check: Annual compressed air supply system functionality test (minimum 10 minutes duration coverage)
  • Area: Annual fire-resistant material inspection (capability to withstand 1,200°C for 8 minutes)
    Check: Annual fire-resistant material inspection (capability to withstand 1,200°C for 8 minutes)
  • Area: Five-year comprehensive third-party classification survey and recertification
    Check: Five-year comprehensive third-party classification survey and recertification
  • Area: Annual ventilation system capacity verification (minimum 5 m³/hour per person for 24 hours)
    Check: Annual ventilation system capacity verification (minimum 5 m³/hour per person for 24 hours)
  • Area: Biennial self-righting mechanism test and hydraulic system performance verification
    Check: Biennial self-righting mechanism test and hydraulic system performance verification

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

Misea Machinery TEL-75F
TEL-75F ✓ verified
Application
Freefall Variant Totally Enclosed Lifeboat
Common Failures & Inspection Points
  • Area: Weekly engine system inspection and functional testing per SOLAS requirements
    Check: Weekly engine system inspection and functional testing per SOLAS requirements
  • Area: Monthly lifeboat release mechanism testing and load line verification
    Check: Monthly lifeboat release mechanism testing and load line verification
  • Area: Quarterly visual inspection of airtight seals, hatches, and hull integrity for corrosion or damage
    Check: Quarterly visual inspection of airtight seals, hatches, and hull integrity for corrosion or damage
  • Area: Annual compressed air supply system functionality test (minimum 10 minutes duration coverage)
    Check: Annual compressed air supply system functionality test (minimum 10 minutes duration coverage)
  • Area: Annual fire-resistant material inspection (capability to withstand 1,200°C for 8 minutes)
    Check: Annual fire-resistant material inspection (capability to withstand 1,200°C for 8 minutes)
  • Area: Five-year comprehensive third-party classification survey and recertification
    Check: Five-year comprehensive third-party classification survey and recertification
  • Area: Annual ventilation system capacity verification (minimum 5 m³/hour per person for 24 hours)
    Check: Annual ventilation system capacity verification (minimum 5 m³/hour per person for 24 hours)
  • Area: Biennial self-righting mechanism test and hydraulic system performance verification
    Check: Biennial self-righting mechanism test and hydraulic system performance verification

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

Misea Machinery TEL-85C
TEL-85C ✓ verified
Application
Conventional Totally Enclosed Lifeboat
Common Failures & Inspection Points
  • Area: Weekly engine system inspection and functional testing per SOLAS requirements
    Check: Weekly engine system inspection and functional testing per SOLAS requirements
  • Area: Monthly lifeboat release mechanism testing and load line verification
    Check: Monthly lifeboat release mechanism testing and load line verification
  • Area: Quarterly visual inspection of airtight seals, hatches, and hull integrity for corrosion or damage
    Check: Quarterly visual inspection of airtight seals, hatches, and hull integrity for corrosion or damage
  • Area: Annual compressed air supply system functionality test (minimum 10 minutes duration coverage)
    Check: Annual compressed air supply system functionality test (minimum 10 minutes duration coverage)
  • Area: Annual fire-resistant material inspection (capability to withstand 1,200°C for 8 minutes)
    Check: Annual fire-resistant material inspection (capability to withstand 1,200°C for 8 minutes)
  • Area: Five-year comprehensive third-party classification survey and recertification
    Check: Five-year comprehensive third-party classification survey and recertification
  • Area: Annual ventilation system capacity verification (minimum 5 m³/hour per person for 24 hours)
    Check: Annual ventilation system capacity verification (minimum 5 m³/hour per person for 24 hours)
  • Area: Biennial self-righting mechanism test and hydraulic system performance verification
    Check: Biennial self-righting mechanism test and hydraulic system performance verification

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

Misea Machinery TEL-85F
TEL-85F ✓ verified
Application
Freefall Variant Totally Enclosed Lifeboat
Common Failures & Inspection Points
  • Area: Weekly engine system inspection and functional testing per SOLAS requirements
    Check: Weekly engine system inspection and functional testing per SOLAS requirements
  • Area: Monthly lifeboat release mechanism testing and load line verification
    Check: Monthly lifeboat release mechanism testing and load line verification
  • Area: Quarterly visual inspection of airtight seals, hatches, and hull integrity for corrosion or damage
    Check: Quarterly visual inspection of airtight seals, hatches, and hull integrity for corrosion or damage
  • Area: Annual compressed air supply system functionality test (minimum 10 minutes duration coverage)
    Check: Annual compressed air supply system functionality test (minimum 10 minutes duration coverage)
  • Area: Annual fire-resistant material inspection (capability to withstand 1,200°C for 8 minutes)
    Check: Annual fire-resistant material inspection (capability to withstand 1,200°C for 8 minutes)
  • Area: Five-year comprehensive third-party classification survey and recertification
    Check: Five-year comprehensive third-party classification survey and recertification
  • Area: Annual ventilation system capacity verification (minimum 5 m³/hour per person for 24 hours)
    Check: Annual ventilation system capacity verification (minimum 5 m³/hour per person for 24 hours)
  • Area: Biennial self-righting mechanism test and hydraulic system performance verification
    Check: Biennial self-righting mechanism test and hydraulic system performance verification

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

Misea Machinery TEL-D85C
TEL-D85C ✓ verified
Application
Conventional Totally Enclosed Lifeboat (Extended Capacity)
Common Failures & Inspection Points
  • Area: Weekly engine system inspection and functional testing per SOLAS requirements
    Check: Weekly engine system inspection and functional testing per SOLAS requirements
  • Area: Monthly lifeboat release mechanism testing and load line verification
    Check: Monthly lifeboat release mechanism testing and load line verification
  • Area: Quarterly visual inspection of airtight seals, hatches, and hull integrity for corrosion or damage
    Check: Quarterly visual inspection of airtight seals, hatches, and hull integrity for corrosion or damage
  • Area: Annual compressed air supply system functionality test (minimum 10 minutes duration coverage)
    Check: Annual compressed air supply system functionality test (minimum 10 minutes duration coverage)
  • Area: Annual fire-resistant material inspection (capability to withstand 1,200°C for 8 minutes)
    Check: Annual fire-resistant material inspection (capability to withstand 1,200°C for 8 minutes)
  • Area: Five-year comprehensive third-party classification survey and recertification
    Check: Five-year comprehensive third-party classification survey and recertification
  • Area: Annual ventilation system capacity verification (minimum 5 m³/hour per person for 24 hours)
    Check: Annual ventilation system capacity verification (minimum 5 m³/hour per person for 24 hours)
  • Area: Biennial self-righting mechanism test and hydraulic system performance verification
    Check: Biennial self-righting mechanism test and hydraulic system performance verification

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

Misea Machinery TEL-D85F
TEL-D85F ✓ verified
Application
Freefall Variant Totally Enclosed Lifeboat (Extended Capacity)
Common Failures & Inspection Points
  • Area: Weekly engine system inspection and functional testing per SOLAS requirements
    Check: Weekly engine system inspection and functional testing per SOLAS requirements
  • Area: Monthly lifeboat release mechanism testing and load line verification
    Check: Monthly lifeboat release mechanism testing and load line verification
  • Area: Quarterly visual inspection of airtight seals, hatches, and hull integrity for corrosion or damage
    Check: Quarterly visual inspection of airtight seals, hatches, and hull integrity for corrosion or damage
  • Area: Annual compressed air supply system functionality test (minimum 10 minutes duration coverage)
    Check: Annual compressed air supply system functionality test (minimum 10 minutes duration coverage)
  • Area: Annual fire-resistant material inspection (capability to withstand 1,200°C for 8 minutes)
    Check: Annual fire-resistant material inspection (capability to withstand 1,200°C for 8 minutes)
  • Area: Five-year comprehensive third-party classification survey and recertification
    Check: Five-year comprehensive third-party classification survey and recertification
  • Area: Annual ventilation system capacity verification (minimum 5 m³/hour per person for 24 hours)
    Check: Annual ventilation system capacity verification (minimum 5 m³/hour per person for 24 hours)
  • Area: Biennial self-righting mechanism test and hydraulic system performance verification
    Check: Biennial self-righting mechanism test and hydraulic system performance verification

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

Misea Machinery FFL-49FC
FFL-49FC ✓ verified
Application
Freefall Lifeboat
Common Failures & Inspection Points
  • Area: Weekly engine system inspection and functional testing per SOLAS requirements
    Check: Weekly engine system inspection and functional testing per SOLAS requirements
  • Area: Monthly lifeboat release mechanism testing and load line verification
    Check: Monthly lifeboat release mechanism testing and load line verification
  • Area: Quarterly visual inspection of airtight seals, hatches, and hull integrity for corrosion or damage
    Check: Quarterly visual inspection of airtight seals, hatches, and hull integrity for corrosion or damage
  • Area: Annual compressed air supply system functionality test (minimum 10 minutes duration coverage)
    Check: Annual compressed air supply system functionality test (minimum 10 minutes duration coverage)
  • Area: Annual fire-resistant material inspection (capability to withstand 1,200°C for 8 minutes)
    Check: Annual fire-resistant material inspection (capability to withstand 1,200°C for 8 minutes)
  • Area: Five-year comprehensive third-party classification survey and recertification
    Check: Five-year comprehensive third-party classification survey and recertification
  • Area: Annual ventilation system capacity verification (minimum 5 m³/hour per person for 24 hours)
    Check: Annual ventilation system capacity verification (minimum 5 m³/hour per person for 24 hours)
  • Area: Biennial self-righting mechanism test and hydraulic system performance verification
    Check: Biennial self-righting mechanism test and hydraulic system performance verification

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

Misea Machinery FFL-49FF
FFL-49FF ✓ verified
Application
Freefall Lifeboat
Common Failures & Inspection Points
  • Area: Weekly engine system inspection and functional testing per SOLAS requirements
    Check: Weekly engine system inspection and functional testing per SOLAS requirements
  • Area: Monthly lifeboat release mechanism testing and load line verification
    Check: Monthly lifeboat release mechanism testing and load line verification
  • Area: Quarterly visual inspection of airtight seals, hatches, and hull integrity for corrosion or damage
    Check: Quarterly visual inspection of airtight seals, hatches, and hull integrity for corrosion or damage
  • Area: Annual compressed air supply system functionality test (minimum 10 minutes duration coverage)
    Check: Annual compressed air supply system functionality test (minimum 10 minutes duration coverage)
  • Area: Annual fire-resistant material inspection (capability to withstand 1,200°C for 8 minutes)
    Check: Annual fire-resistant material inspection (capability to withstand 1,200°C for 8 minutes)
  • Area: Five-year comprehensive third-party classification survey and recertification
    Check: Five-year comprehensive third-party classification survey and recertification
  • Area: Annual ventilation system capacity verification (minimum 5 m³/hour per person for 24 hours)
    Check: Annual ventilation system capacity verification (minimum 5 m³/hour per person for 24 hours)
  • Area: Biennial self-righting mechanism test and hydraulic system performance verification
    Check: Biennial self-righting mechanism test and hydraulic system performance verification

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

Misea Machinery FFL-52FC
FFL-52FC ✓ verified
Application
Freefall Lifeboat
Common Failures & Inspection Points
  • Area: Weekly engine system inspection and functional testing per SOLAS requirements
    Check: Weekly engine system inspection and functional testing per SOLAS requirements
  • Area: Monthly lifeboat release mechanism testing and load line verification
    Check: Monthly lifeboat release mechanism testing and load line verification
  • Area: Quarterly visual inspection of airtight seals, hatches, and hull integrity for corrosion or damage
    Check: Quarterly visual inspection of airtight seals, hatches, and hull integrity for corrosion or damage
  • Area: Annual compressed air supply system functionality test (minimum 10 minutes duration coverage)
    Check: Annual compressed air supply system functionality test (minimum 10 minutes duration coverage)
  • Area: Annual fire-resistant material inspection (capability to withstand 1,200°C for 8 minutes)
    Check: Annual fire-resistant material inspection (capability to withstand 1,200°C for 8 minutes)
  • Area: Five-year comprehensive third-party classification survey and recertification
    Check: Five-year comprehensive third-party classification survey and recertification
  • Area: Annual ventilation system capacity verification (minimum 5 m³/hour per person for 24 hours)
    Check: Annual ventilation system capacity verification (minimum 5 m³/hour per person for 24 hours)
  • Area: Biennial self-righting mechanism test and hydraulic system performance verification
    Check: Biennial self-righting mechanism test and hydraulic system performance verification

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

Misea Machinery FFL-52FF
FFL-52FF ✓ verified
Application
Freefall Lifeboat
Common Failures & Inspection Points
  • Area: Weekly engine system inspection and functional testing per SOLAS requirements
    Check: Weekly engine system inspection and functional testing per SOLAS requirements
  • Area: Monthly lifeboat release mechanism testing and load line verification
    Check: Monthly lifeboat release mechanism testing and load line verification
  • Area: Quarterly visual inspection of airtight seals, hatches, and hull integrity for corrosion or damage
    Check: Quarterly visual inspection of airtight seals, hatches, and hull integrity for corrosion or damage
  • Area: Annual compressed air supply system functionality test (minimum 10 minutes duration coverage)
    Check: Annual compressed air supply system functionality test (minimum 10 minutes duration coverage)
  • Area: Annual fire-resistant material inspection (capability to withstand 1,200°C for 8 minutes)
    Check: Annual fire-resistant material inspection (capability to withstand 1,200°C for 8 minutes)
  • Area: Five-year comprehensive third-party classification survey and recertification
    Check: Five-year comprehensive third-party classification survey and recertification
  • Area: Annual ventilation system capacity verification (minimum 5 m³/hour per person for 24 hours)
    Check: Annual ventilation system capacity verification (minimum 5 m³/hour per person for 24 hours)
  • Area: Biennial self-righting mechanism test and hydraulic system performance verification
    Check: Biennial self-righting mechanism test and hydraulic system performance verification

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

Misea Machinery FFL-59FC
FFL-59FC ✓ verified
Application
Freefall Lifeboat
Common Failures & Inspection Points
  • Area: Weekly engine system inspection and functional testing per SOLAS requirements
    Check: Weekly engine system inspection and functional testing per SOLAS requirements
  • Area: Monthly lifeboat release mechanism testing and load line verification
    Check: Monthly lifeboat release mechanism testing and load line verification
  • Area: Quarterly visual inspection of airtight seals, hatches, and hull integrity for corrosion or damage
    Check: Quarterly visual inspection of airtight seals, hatches, and hull integrity for corrosion or damage
  • Area: Annual compressed air supply system functionality test (minimum 10 minutes duration coverage)
    Check: Annual compressed air supply system functionality test (minimum 10 minutes duration coverage)
  • Area: Annual fire-resistant material inspection (capability to withstand 1,200°C for 8 minutes)
    Check: Annual fire-resistant material inspection (capability to withstand 1,200°C for 8 minutes)
  • Area: Five-year comprehensive third-party classification survey and recertification
    Check: Five-year comprehensive third-party classification survey and recertification
  • Area: Annual ventilation system capacity verification (minimum 5 m³/hour per person for 24 hours)
    Check: Annual ventilation system capacity verification (minimum 5 m³/hour per person for 24 hours)
  • Area: Biennial self-righting mechanism test and hydraulic system performance verification
    Check: Biennial self-righting mechanism test and hydraulic system performance verification

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

Misea Machinery FFL-59FF
FFL-59FF ✓ verified
Application
Freefall Lifeboat
Common Failures & Inspection Points
  • Area: Weekly engine system inspection and functional testing per SOLAS requirements
    Check: Weekly engine system inspection and functional testing per SOLAS requirements
  • Area: Monthly lifeboat release mechanism testing and load line verification
    Check: Monthly lifeboat release mechanism testing and load line verification
  • Area: Quarterly visual inspection of airtight seals, hatches, and hull integrity for corrosion or damage
    Check: Quarterly visual inspection of airtight seals, hatches, and hull integrity for corrosion or damage
  • Area: Annual compressed air supply system functionality test (minimum 10 minutes duration coverage)
    Check: Annual compressed air supply system functionality test (minimum 10 minutes duration coverage)
  • Area: Annual fire-resistant material inspection (capability to withstand 1,200°C for 8 minutes)
    Check: Annual fire-resistant material inspection (capability to withstand 1,200°C for 8 minutes)
  • Area: Five-year comprehensive third-party classification survey and recertification
    Check: Five-year comprehensive third-party classification survey and recertification
  • Area: Annual ventilation system capacity verification (minimum 5 m³/hour per person for 24 hours)
    Check: Annual ventilation system capacity verification (minimum 5 m³/hour per person for 24 hours)
  • Area: Biennial self-righting mechanism test and hydraulic system performance verification
    Check: Biennial self-righting mechanism test and hydraulic system performance verification

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

Misea Machinery FFL-66FC
FFL-66FC ✓ verified
Application
Freefall Lifeboat
Common Failures & Inspection Points
  • Area: Weekly engine system inspection and functional testing per SOLAS requirements
    Check: Weekly engine system inspection and functional testing per SOLAS requirements
  • Area: Monthly lifeboat release mechanism testing and load line verification
    Check: Monthly lifeboat release mechanism testing and load line verification
  • Area: Quarterly visual inspection of airtight seals, hatches, and hull integrity for corrosion or damage
    Check: Quarterly visual inspection of airtight seals, hatches, and hull integrity for corrosion or damage
  • Area: Annual compressed air supply system functionality test (minimum 10 minutes duration coverage)
    Check: Annual compressed air supply system functionality test (minimum 10 minutes duration coverage)
  • Area: Annual fire-resistant material inspection (capability to withstand 1,200°C for 8 minutes)
    Check: Annual fire-resistant material inspection (capability to withstand 1,200°C for 8 minutes)
  • Area: Five-year comprehensive third-party classification survey and recertification
    Check: Five-year comprehensive third-party classification survey and recertification
  • Area: Annual ventilation system capacity verification (minimum 5 m³/hour per person for 24 hours)
    Check: Annual ventilation system capacity verification (minimum 5 m³/hour per person for 24 hours)
  • Area: Biennial self-righting mechanism test and hydraulic system performance verification
    Check: Biennial self-righting mechanism test and hydraulic system performance verification

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

Misea Machinery FFL-66FF
FFL-66FF ✓ verified
Application
Freefall Lifeboat
Common Failures & Inspection Points
  • Area: Weekly engine system inspection and functional testing per SOLAS requirements
    Check: Weekly engine system inspection and functional testing per SOLAS requirements
  • Area: Monthly lifeboat release mechanism testing and load line verification
    Check: Monthly lifeboat release mechanism testing and load line verification
  • Area: Quarterly visual inspection of airtight seals, hatches, and hull integrity for corrosion or damage
    Check: Quarterly visual inspection of airtight seals, hatches, and hull integrity for corrosion or damage
  • Area: Annual compressed air supply system functionality test (minimum 10 minutes duration coverage)
    Check: Annual compressed air supply system functionality test (minimum 10 minutes duration coverage)
  • Area: Annual fire-resistant material inspection (capability to withstand 1,200°C for 8 minutes)
    Check: Annual fire-resistant material inspection (capability to withstand 1,200°C for 8 minutes)
  • Area: Five-year comprehensive third-party classification survey and recertification
    Check: Five-year comprehensive third-party classification survey and recertification
  • Area: Annual ventilation system capacity verification (minimum 5 m³/hour per person for 24 hours)
    Check: Annual ventilation system capacity verification (minimum 5 m³/hour per person for 24 hours)
  • Area: Biennial self-righting mechanism test and hydraulic system performance verification
    Check: Biennial self-righting mechanism test and hydraulic system performance verification

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

PALFINGER

16 ✓ 16 verified
PALFINGER TECB 22C / TECB 22T
TECB 22C / TECB 22T ✓ verified
Application
Totally Enclosed Lifeboat - Compact model
Common Failures & Inspection Points
  • Area: Hull structural integrity and crack inspection (visual and non-destructive testing per SOLAS)
    Check: Hull structural integrity and crack inspection (visual and non-destructive testing per SOLAS)
  • Area: Lifeboat davit and winch system functionality and safety device testing
    Check: Lifeboat davit and winch system functionality and safety device testing
  • Area: Life jacket, lifeline, and personal survival equipment condition per IMO LSA Code
    Check: Life jacket, lifeline, and personal survival equipment condition per IMO LSA Code
  • Area: Engine and fuel system condition including fuel quality testing and filter replacement
    Check: Engine and fuel system condition including fuel quality testing and filter replacement
  • Area: Launching and recovery system verification with load testing (60% working load minimum)
    Check: Launching and recovery system verification with load testing (60% working load minimum)
  • Area: Interior hull condition inspection for osmotic blistering and delamination (GRP models)
    Check: Interior hull condition inspection for osmotic blistering and delamination (GRP models)
  • Area: Safety equipment functionality (flares, signaling equipment, seasickness medication expiration)
    Check: Safety equipment functionality (flares, signaling equipment, seasickness medication expiration)
  • Area: Annual certification maintenance per maritime classification authority requirements (MED, USCG, or equivalent)
    Check: Annual certification maintenance per maritime classification authority requirements (MED, USCG, or equivalent)

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

PALFINGER TECB 24C / TECB 24T
TECB 24C / TECB 24T ✓ verified
Application
Totally Enclosed Lifeboat - Extended compact model
Common Failures & Inspection Points
  • Area: Hull structural integrity and crack inspection (visual and non-destructive testing per SOLAS)
    Check: Hull structural integrity and crack inspection (visual and non-destructive testing per SOLAS)
  • Area: Lifeboat davit and winch system functionality and safety device testing
    Check: Lifeboat davit and winch system functionality and safety device testing
  • Area: Life jacket, lifeline, and personal survival equipment condition per IMO LSA Code
    Check: Life jacket, lifeline, and personal survival equipment condition per IMO LSA Code
  • Area: Engine and fuel system condition including fuel quality testing and filter replacement
    Check: Engine and fuel system condition including fuel quality testing and filter replacement
  • Area: Launching and recovery system verification with load testing (60% working load minimum)
    Check: Launching and recovery system verification with load testing (60% working load minimum)
  • Area: Interior hull condition inspection for osmotic blistering and delamination (GRP models)
    Check: Interior hull condition inspection for osmotic blistering and delamination (GRP models)
  • Area: Safety equipment functionality (flares, signaling equipment, seasickness medication expiration)
    Check: Safety equipment functionality (flares, signaling equipment, seasickness medication expiration)
  • Area: Annual certification maintenance per maritime classification authority requirements (MED, USCG, or equivalent)
    Check: Annual certification maintenance per maritime classification authority requirements (MED, USCG, or equivalent)

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

PALFINGER KISS 700C / KISS 700T
KISS 700C / KISS 700T ✓ verified
Application
Totally Enclosed Lifeboat - Compact rescue boat
Common Failures & Inspection Points
  • Area: Hull structural integrity and crack inspection (visual and non-destructive testing per SOLAS)
    Check: Hull structural integrity and crack inspection (visual and non-destructive testing per SOLAS)
  • Area: Lifeboat davit and winch system functionality and safety device testing
    Check: Lifeboat davit and winch system functionality and safety device testing
  • Area: Life jacket, lifeline, and personal survival equipment condition per IMO LSA Code
    Check: Life jacket, lifeline, and personal survival equipment condition per IMO LSA Code
  • Area: Engine and fuel system condition including fuel quality testing and filter replacement
    Check: Engine and fuel system condition including fuel quality testing and filter replacement
  • Area: Launching and recovery system verification with load testing (60% working load minimum)
    Check: Launching and recovery system verification with load testing (60% working load minimum)
  • Area: Interior hull condition inspection for osmotic blistering and delamination (GRP models)
    Check: Interior hull condition inspection for osmotic blistering and delamination (GRP models)
  • Area: Safety equipment functionality (flares, signaling equipment, seasickness medication expiration)
    Check: Safety equipment functionality (flares, signaling equipment, seasickness medication expiration)
  • Area: Annual certification maintenance per maritime classification authority requirements (MED, USCG, or equivalent)
    Check: Annual certification maintenance per maritime classification authority requirements (MED, USCG, or equivalent)

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

PALFINGER KISS 800C / KISS 800T
KISS 800C / KISS 800T ✓ verified
Application
Totally Enclosed Lifeboat - Medium rescue boat
Common Failures & Inspection Points
  • Area: Hull structural integrity and crack inspection (visual and non-destructive testing per SOLAS)
    Check: Hull structural integrity and crack inspection (visual and non-destructive testing per SOLAS)
  • Area: Lifeboat davit and winch system functionality and safety device testing
    Check: Lifeboat davit and winch system functionality and safety device testing
  • Area: Life jacket, lifeline, and personal survival equipment condition per IMO LSA Code
    Check: Life jacket, lifeline, and personal survival equipment condition per IMO LSA Code
  • Area: Engine and fuel system condition including fuel quality testing and filter replacement
    Check: Engine and fuel system condition including fuel quality testing and filter replacement
  • Area: Launching and recovery system verification with load testing (60% working load minimum)
    Check: Launching and recovery system verification with load testing (60% working load minimum)
  • Area: Interior hull condition inspection for osmotic blistering and delamination (GRP models)
    Check: Interior hull condition inspection for osmotic blistering and delamination (GRP models)
  • Area: Safety equipment functionality (flares, signaling equipment, seasickness medication expiration)
    Check: Safety equipment functionality (flares, signaling equipment, seasickness medication expiration)
  • Area: Annual certification maintenance per maritime classification authority requirements (MED, USCG, or equivalent)
    Check: Annual certification maintenance per maritime classification authority requirements (MED, USCG, or equivalent)

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

PALFINGER KISS 1000C / KISS 1000T
KISS 1000C / KISS 1000T ✓ verified
Application
Totally Enclosed Lifeboat - Large rescue boat
Common Failures & Inspection Points
  • Area: Hull structural integrity and crack inspection (visual and non-destructive testing per SOLAS)
    Check: Hull structural integrity and crack inspection (visual and non-destructive testing per SOLAS)
  • Area: Lifeboat davit and winch system functionality and safety device testing
    Check: Lifeboat davit and winch system functionality and safety device testing
  • Area: Life jacket, lifeline, and personal survival equipment condition per IMO LSA Code
    Check: Life jacket, lifeline, and personal survival equipment condition per IMO LSA Code
  • Area: Engine and fuel system condition including fuel quality testing and filter replacement
    Check: Engine and fuel system condition including fuel quality testing and filter replacement
  • Area: Launching and recovery system verification with load testing (60% working load minimum)
    Check: Launching and recovery system verification with load testing (60% working load minimum)
  • Area: Interior hull condition inspection for osmotic blistering and delamination (GRP models)
    Check: Interior hull condition inspection for osmotic blistering and delamination (GRP models)
  • Area: Safety equipment functionality (flares, signaling equipment, seasickness medication expiration)
    Check: Safety equipment functionality (flares, signaling equipment, seasickness medication expiration)
  • Area: Annual certification maintenance per maritime classification authority requirements (MED, USCG, or equivalent)
    Check: Annual certification maintenance per maritime classification authority requirements (MED, USCG, or equivalent)

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

PALFINGER P-TELB 850C / P-TELB 850T
P-TELB 850C / P-TELB 850T ✓ verified
Application
Totally Enclosed Lifeboat - Compact passenger model
Common Failures & Inspection Points
  • Area: Hull structural integrity and crack inspection (visual and non-destructive testing per SOLAS)
    Check: Hull structural integrity and crack inspection (visual and non-destructive testing per SOLAS)
  • Area: Lifeboat davit and winch system functionality and safety device testing
    Check: Lifeboat davit and winch system functionality and safety device testing
  • Area: Life jacket, lifeline, and personal survival equipment condition per IMO LSA Code
    Check: Life jacket, lifeline, and personal survival equipment condition per IMO LSA Code
  • Area: Engine and fuel system condition including fuel quality testing and filter replacement
    Check: Engine and fuel system condition including fuel quality testing and filter replacement
  • Area: Launching and recovery system verification with load testing (60% working load minimum)
    Check: Launching and recovery system verification with load testing (60% working load minimum)
  • Area: Interior hull condition inspection for osmotic blistering and delamination (GRP models)
    Check: Interior hull condition inspection for osmotic blistering and delamination (GRP models)
  • Area: Safety equipment functionality (flares, signaling equipment, seasickness medication expiration)
    Check: Safety equipment functionality (flares, signaling equipment, seasickness medication expiration)
  • Area: Annual certification maintenance per maritime classification authority requirements (MED, USCG, or equivalent)
    Check: Annual certification maintenance per maritime classification authority requirements (MED, USCG, or equivalent)

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

PALFINGER P-TELB 1030C / P-TELB 1030T
P-TELB 1030C / P-TELB 1030T ✓ verified
Application
Totally Enclosed Lifeboat - Medium passenger model
Common Failures & Inspection Points
  • Area: Hull structural integrity and crack inspection (visual and non-destructive testing per SOLAS)
    Check: Hull structural integrity and crack inspection (visual and non-destructive testing per SOLAS)
  • Area: Lifeboat davit and winch system functionality and safety device testing
    Check: Lifeboat davit and winch system functionality and safety device testing
  • Area: Life jacket, lifeline, and personal survival equipment condition per IMO LSA Code
    Check: Life jacket, lifeline, and personal survival equipment condition per IMO LSA Code
  • Area: Engine and fuel system condition including fuel quality testing and filter replacement
    Check: Engine and fuel system condition including fuel quality testing and filter replacement
  • Area: Launching and recovery system verification with load testing (60% working load minimum)
    Check: Launching and recovery system verification with load testing (60% working load minimum)
  • Area: Interior hull condition inspection for osmotic blistering and delamination (GRP models)
    Check: Interior hull condition inspection for osmotic blistering and delamination (GRP models)
  • Area: Safety equipment functionality (flares, signaling equipment, seasickness medication expiration)
    Check: Safety equipment functionality (flares, signaling equipment, seasickness medication expiration)
  • Area: Annual certification maintenance per maritime classification authority requirements (MED, USCG, or equivalent)
    Check: Annual certification maintenance per maritime classification authority requirements (MED, USCG, or equivalent)

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

PALFINGER P-TELB 1170C / P-TELB 1170T
P-TELB 1170C / P-TELB 1170T ✓ verified
Application
Totally Enclosed Lifeboat - Large passenger model
Common Failures & Inspection Points
  • Area: Hull structural integrity and crack inspection (visual and non-destructive testing per SOLAS)
    Check: Hull structural integrity and crack inspection (visual and non-destructive testing per SOLAS)
  • Area: Lifeboat davit and winch system functionality and safety device testing
    Check: Lifeboat davit and winch system functionality and safety device testing
  • Area: Life jacket, lifeline, and personal survival equipment condition per IMO LSA Code
    Check: Life jacket, lifeline, and personal survival equipment condition per IMO LSA Code
  • Area: Engine and fuel system condition including fuel quality testing and filter replacement
    Check: Engine and fuel system condition including fuel quality testing and filter replacement
  • Area: Launching and recovery system verification with load testing (60% working load minimum)
    Check: Launching and recovery system verification with load testing (60% working load minimum)
  • Area: Interior hull condition inspection for osmotic blistering and delamination (GRP models)
    Check: Interior hull condition inspection for osmotic blistering and delamination (GRP models)
  • Area: Safety equipment functionality (flares, signaling equipment, seasickness medication expiration)
    Check: Safety equipment functionality (flares, signaling equipment, seasickness medication expiration)
  • Area: Annual certification maintenance per maritime classification authority requirements (MED, USCG, or equivalent)
    Check: Annual certification maintenance per maritime classification authority requirements (MED, USCG, or equivalent)

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

PALFINGER P-TELB 1350C / P-TELB 1350T
P-TELB 1350C / P-TELB 1350T ✓ verified
Application
Totally Enclosed Lifeboat - Extra-large passenger model
Common Failures & Inspection Points
  • Area: Hull structural integrity and crack inspection (visual and non-destructive testing per SOLAS)
    Check: Hull structural integrity and crack inspection (visual and non-destructive testing per SOLAS)
  • Area: Lifeboat davit and winch system functionality and safety device testing
    Check: Lifeboat davit and winch system functionality and safety device testing
  • Area: Life jacket, lifeline, and personal survival equipment condition per IMO LSA Code
    Check: Life jacket, lifeline, and personal survival equipment condition per IMO LSA Code
  • Area: Engine and fuel system condition including fuel quality testing and filter replacement
    Check: Engine and fuel system condition including fuel quality testing and filter replacement
  • Area: Launching and recovery system verification with load testing (60% working load minimum)
    Check: Launching and recovery system verification with load testing (60% working load minimum)
  • Area: Interior hull condition inspection for osmotic blistering and delamination (GRP models)
    Check: Interior hull condition inspection for osmotic blistering and delamination (GRP models)
  • Area: Safety equipment functionality (flares, signaling equipment, seasickness medication expiration)
    Check: Safety equipment functionality (flares, signaling equipment, seasickness medication expiration)
  • Area: Annual certification maintenance per maritime classification authority requirements (MED, USCG, or equivalent)
    Check: Annual certification maintenance per maritime classification authority requirements (MED, USCG, or equivalent)

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

PALFINGER NPT50C / NPT50F
NPT50C / NPT50F ✓ verified
Application
Totally Enclosed Lifeboat - Compact rescue tender
Common Failures & Inspection Points
  • Area: Hull structural integrity and crack inspection (visual and non-destructive testing per SOLAS)
    Check: Hull structural integrity and crack inspection (visual and non-destructive testing per SOLAS)
  • Area: Lifeboat davit and winch system functionality and safety device testing
    Check: Lifeboat davit and winch system functionality and safety device testing
  • Area: Life jacket, lifeline, and personal survival equipment condition per IMO LSA Code
    Check: Life jacket, lifeline, and personal survival equipment condition per IMO LSA Code
  • Area: Engine and fuel system condition including fuel quality testing and filter replacement
    Check: Engine and fuel system condition including fuel quality testing and filter replacement
  • Area: Launching and recovery system verification with load testing (60% working load minimum)
    Check: Launching and recovery system verification with load testing (60% working load minimum)
  • Area: Interior hull condition inspection for osmotic blistering and delamination (GRP models)
    Check: Interior hull condition inspection for osmotic blistering and delamination (GRP models)
  • Area: Safety equipment functionality (flares, signaling equipment, seasickness medication expiration)
    Check: Safety equipment functionality (flares, signaling equipment, seasickness medication expiration)
  • Area: Annual certification maintenance per maritime classification authority requirements (MED, USCG, or equivalent)
    Check: Annual certification maintenance per maritime classification authority requirements (MED, USCG, or equivalent)

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

PALFINGER NPT60C / NPT60F
NPT60C / NPT60F ✓ verified
Application
Totally Enclosed Lifeboat - Small rescue tender
Common Failures & Inspection Points
  • Area: Hull structural integrity and crack inspection (visual and non-destructive testing per SOLAS)
    Check: Hull structural integrity and crack inspection (visual and non-destructive testing per SOLAS)
  • Area: Lifeboat davit and winch system functionality and safety device testing
    Check: Lifeboat davit and winch system functionality and safety device testing
  • Area: Life jacket, lifeline, and personal survival equipment condition per IMO LSA Code
    Check: Life jacket, lifeline, and personal survival equipment condition per IMO LSA Code
  • Area: Engine and fuel system condition including fuel quality testing and filter replacement
    Check: Engine and fuel system condition including fuel quality testing and filter replacement
  • Area: Launching and recovery system verification with load testing (60% working load minimum)
    Check: Launching and recovery system verification with load testing (60% working load minimum)
  • Area: Interior hull condition inspection for osmotic blistering and delamination (GRP models)
    Check: Interior hull condition inspection for osmotic blistering and delamination (GRP models)
  • Area: Safety equipment functionality (flares, signaling equipment, seasickness medication expiration)
    Check: Safety equipment functionality (flares, signaling equipment, seasickness medication expiration)
  • Area: Annual certification maintenance per maritime classification authority requirements (MED, USCG, or equivalent)
    Check: Annual certification maintenance per maritime classification authority requirements (MED, USCG, or equivalent)

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

PALFINGER NPT58C / NPT58F
NPT58C / NPT58F ✓ verified
Application
Totally Enclosed Lifeboat - Medium rescue tender
Common Failures & Inspection Points
  • Area: Hull structural integrity and crack inspection (visual and non-destructive testing per SOLAS)
    Check: Hull structural integrity and crack inspection (visual and non-destructive testing per SOLAS)
  • Area: Lifeboat davit and winch system functionality and safety device testing
    Check: Lifeboat davit and winch system functionality and safety device testing
  • Area: Life jacket, lifeline, and personal survival equipment condition per IMO LSA Code
    Check: Life jacket, lifeline, and personal survival equipment condition per IMO LSA Code
  • Area: Engine and fuel system condition including fuel quality testing and filter replacement
    Check: Engine and fuel system condition including fuel quality testing and filter replacement
  • Area: Launching and recovery system verification with load testing (60% working load minimum)
    Check: Launching and recovery system verification with load testing (60% working load minimum)
  • Area: Interior hull condition inspection for osmotic blistering and delamination (GRP models)
    Check: Interior hull condition inspection for osmotic blistering and delamination (GRP models)
  • Area: Safety equipment functionality (flares, signaling equipment, seasickness medication expiration)
    Check: Safety equipment functionality (flares, signaling equipment, seasickness medication expiration)
  • Area: Annual certification maintenance per maritime classification authority requirements (MED, USCG, or equivalent)
    Check: Annual certification maintenance per maritime classification authority requirements (MED, USCG, or equivalent)

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

PALFINGER NPT75C / NPT75F
NPT75C / NPT75F ✓ verified
Application
Totally Enclosed Lifeboat - Medium-large rescue tender
Common Failures & Inspection Points
  • Area: Hull structural integrity and crack inspection (visual and non-destructive testing per SOLAS)
    Check: Hull structural integrity and crack inspection (visual and non-destructive testing per SOLAS)
  • Area: Lifeboat davit and winch system functionality and safety device testing
    Check: Lifeboat davit and winch system functionality and safety device testing
  • Area: Life jacket, lifeline, and personal survival equipment condition per IMO LSA Code
    Check: Life jacket, lifeline, and personal survival equipment condition per IMO LSA Code
  • Area: Engine and fuel system condition including fuel quality testing and filter replacement
    Check: Engine and fuel system condition including fuel quality testing and filter replacement
  • Area: Launching and recovery system verification with load testing (60% working load minimum)
    Check: Launching and recovery system verification with load testing (60% working load minimum)
  • Area: Interior hull condition inspection for osmotic blistering and delamination (GRP models)
    Check: Interior hull condition inspection for osmotic blistering and delamination (GRP models)
  • Area: Safety equipment functionality (flares, signaling equipment, seasickness medication expiration)
    Check: Safety equipment functionality (flares, signaling equipment, seasickness medication expiration)
  • Area: Annual certification maintenance per maritime classification authority requirements (MED, USCG, or equivalent)
    Check: Annual certification maintenance per maritime classification authority requirements (MED, USCG, or equivalent)

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

PALFINGER NPT85C / NPT85F
NPT85C / NPT85F ✓ verified
Application
Totally Enclosed Lifeboat - Large rescue tender
Common Failures & Inspection Points
  • Area: Hull structural integrity and crack inspection (visual and non-destructive testing per SOLAS)
    Check: Hull structural integrity and crack inspection (visual and non-destructive testing per SOLAS)
  • Area: Lifeboat davit and winch system functionality and safety device testing
    Check: Lifeboat davit and winch system functionality and safety device testing
  • Area: Life jacket, lifeline, and personal survival equipment condition per IMO LSA Code
    Check: Life jacket, lifeline, and personal survival equipment condition per IMO LSA Code
  • Area: Engine and fuel system condition including fuel quality testing and filter replacement
    Check: Engine and fuel system condition including fuel quality testing and filter replacement
  • Area: Launching and recovery system verification with load testing (60% working load minimum)
    Check: Launching and recovery system verification with load testing (60% working load minimum)
  • Area: Interior hull condition inspection for osmotic blistering and delamination (GRP models)
    Check: Interior hull condition inspection for osmotic blistering and delamination (GRP models)
  • Area: Safety equipment functionality (flares, signaling equipment, seasickness medication expiration)
    Check: Safety equipment functionality (flares, signaling equipment, seasickness medication expiration)
  • Area: Annual certification maintenance per maritime classification authority requirements (MED, USCG, or equivalent)
    Check: Annual certification maintenance per maritime classification authority requirements (MED, USCG, or equivalent)

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

PALFINGER NPT95C / NPT95F
NPT95C / NPT95F ✓ verified
Application
Totally Enclosed Lifeboat - Extra-large rescue tender
Common Failures & Inspection Points
  • Area: Hull structural integrity and crack inspection (visual and non-destructive testing per SOLAS)
    Check: Hull structural integrity and crack inspection (visual and non-destructive testing per SOLAS)
  • Area: Lifeboat davit and winch system functionality and safety device testing
    Check: Lifeboat davit and winch system functionality and safety device testing
  • Area: Life jacket, lifeline, and personal survival equipment condition per IMO LSA Code
    Check: Life jacket, lifeline, and personal survival equipment condition per IMO LSA Code
  • Area: Engine and fuel system condition including fuel quality testing and filter replacement
    Check: Engine and fuel system condition including fuel quality testing and filter replacement
  • Area: Launching and recovery system verification with load testing (60% working load minimum)
    Check: Launching and recovery system verification with load testing (60% working load minimum)
  • Area: Interior hull condition inspection for osmotic blistering and delamination (GRP models)
    Check: Interior hull condition inspection for osmotic blistering and delamination (GRP models)
  • Area: Safety equipment functionality (flares, signaling equipment, seasickness medication expiration)
    Check: Safety equipment functionality (flares, signaling equipment, seasickness medication expiration)
  • Area: Annual certification maintenance per maritime classification authority requirements (MED, USCG, or equivalent)
    Check: Annual certification maintenance per maritime classification authority requirements (MED, USCG, or equivalent)

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

PALFINGER NPT150C / NPT150F
NPT150C / NPT150F ✓ verified
Application
Totally Enclosed Lifeboat - Maximum capacity rescue tender
Common Failures & Inspection Points
  • Area: Hull structural integrity and crack inspection (visual and non-destructive testing per SOLAS)
    Check: Hull structural integrity and crack inspection (visual and non-destructive testing per SOLAS)
  • Area: Lifeboat davit and winch system functionality and safety device testing
    Check: Lifeboat davit and winch system functionality and safety device testing
  • Area: Life jacket, lifeline, and personal survival equipment condition per IMO LSA Code
    Check: Life jacket, lifeline, and personal survival equipment condition per IMO LSA Code
  • Area: Engine and fuel system condition including fuel quality testing and filter replacement
    Check: Engine and fuel system condition including fuel quality testing and filter replacement
  • Area: Launching and recovery system verification with load testing (60% working load minimum)
    Check: Launching and recovery system verification with load testing (60% working load minimum)
  • Area: Interior hull condition inspection for osmotic blistering and delamination (GRP models)
    Check: Interior hull condition inspection for osmotic blistering and delamination (GRP models)
  • Area: Safety equipment functionality (flares, signaling equipment, seasickness medication expiration)
    Check: Safety equipment functionality (flares, signaling equipment, seasickness medication expiration)
  • Area: Annual certification maintenance per maritime classification authority requirements (MED, USCG, or equivalent)
    Check: Annual certification maintenance per maritime classification authority requirements (MED, USCG, or equivalent)

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

Fassmer Maritime

11 ✓ 11 verified
Fassmer Maritime CLR (Compact Life- and Rescue Boat) - 16 persons
CLR (Compact Life- and Rescue Boat) - 16 persons ✓ verified
Application
Totally enclosed lifeboat for ships, commercial and offshore vessels
Common Failures & Inspection Points
  • Area: Weekly visual inspection of hull integrity, composite structure for cracks, and all seals for water tightness
    Check: Weekly visual inspection of hull integrity, composite structure for cracks, and all seals for water tightness
  • Area: Weekly engine start-up and run for minimum 3 minutes at operating temperature to verify propulsion system functionality
    Check: Weekly engine start-up and run for minimum 3 minutes at operating temperature to verify propulsion system functionality
  • Area: Monthly turn-out from stowed position without crew to test davit and launching appliance operation
    Check: Monthly turn-out from stowed position without crew to test davit and launching appliance operation
  • Area: Monthly verification of release gear reset condition and hook attachment security
    Check: Monthly verification of release gear reset condition and hook attachment security
  • Area: Annual thorough examination of lifeboat structure, propulsion systems, maneuvering controls, and airtight door seals by competent certified personnel
    Check: Annual thorough examination of lifeboat structure, propulsion systems, maneuvering controls, and airtight door seals by competent certified personnel
  • Area: Annual inspection of ventilation system and air supply lines including CO2 bottles and sprinkler system (if applicable)
    Check: Annual inspection of ventilation system and air supply lines including CO2 bottles and sprinkler system (if applicable)
  • Area: Annual davit inspection including structural condition, wire rope condition, sheaves, and lubrication of moving parts
    Check: Annual davit inspection including structural condition, wire rope condition, sheaves, and lubrication of moving parts
  • Area: Five-yearly renewal of wire rope falls and load testing of on-load/off-load release gear at 1.1x rated capacity
    Check: Five-yearly renewal of wire rope falls and load testing of on-load/off-load release gear at 1.1x rated capacity
  • Area: Quarterly operational drills with assigned crew aboard to verify launching procedures and equipment readiness
    Check: Quarterly operational drills with assigned crew aboard to verify launching procedures and equipment readiness

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

Fassmer Maritime CLR (Compact Life- and Rescue Boat) - 25 persons
CLR (Compact Life- and Rescue Boat) - 25 persons ✓ verified
Application
Totally enclosed lifeboat for ships, commercial and offshore vessels
Common Failures & Inspection Points
  • Area: Weekly visual inspection of hull integrity, composite structure for cracks, and all seals for water tightness
    Check: Weekly visual inspection of hull integrity, composite structure for cracks, and all seals for water tightness
  • Area: Weekly engine start-up and run for minimum 3 minutes at operating temperature to verify propulsion system functionality
    Check: Weekly engine start-up and run for minimum 3 minutes at operating temperature to verify propulsion system functionality
  • Area: Monthly turn-out from stowed position without crew to test davit and launching appliance operation
    Check: Monthly turn-out from stowed position without crew to test davit and launching appliance operation
  • Area: Monthly verification of release gear reset condition and hook attachment security
    Check: Monthly verification of release gear reset condition and hook attachment security
  • Area: Annual thorough examination of lifeboat structure, propulsion systems, maneuvering controls, and airtight door seals by competent certified personnel
    Check: Annual thorough examination of lifeboat structure, propulsion systems, maneuvering controls, and airtight door seals by competent certified personnel
  • Area: Annual inspection of ventilation system and air supply lines including CO2 bottles and sprinkler system (if applicable)
    Check: Annual inspection of ventilation system and air supply lines including CO2 bottles and sprinkler system (if applicable)
  • Area: Annual davit inspection including structural condition, wire rope condition, sheaves, and lubrication of moving parts
    Check: Annual davit inspection including structural condition, wire rope condition, sheaves, and lubrication of moving parts
  • Area: Five-yearly renewal of wire rope falls and load testing of on-load/off-load release gear at 1.1x rated capacity
    Check: Five-yearly renewal of wire rope falls and load testing of on-load/off-load release gear at 1.1x rated capacity
  • Area: Quarterly operational drills with assigned crew aboard to verify launching procedures and equipment readiness
    Check: Quarterly operational drills with assigned crew aboard to verify launching procedures and equipment readiness

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

Fassmer Maritime CLR (Compact Life- and Rescue Boat) - 39 persons
CLR (Compact Life- and Rescue Boat) - 39 persons ✓ verified
Application
Totally enclosed lifeboat for ships, commercial and offshore vessels
Common Failures & Inspection Points
  • Area: Weekly visual inspection of hull integrity, composite structure for cracks, and all seals for water tightness
    Check: Weekly visual inspection of hull integrity, composite structure for cracks, and all seals for water tightness
  • Area: Weekly engine start-up and run for minimum 3 minutes at operating temperature to verify propulsion system functionality
    Check: Weekly engine start-up and run for minimum 3 minutes at operating temperature to verify propulsion system functionality
  • Area: Monthly turn-out from stowed position without crew to test davit and launching appliance operation
    Check: Monthly turn-out from stowed position without crew to test davit and launching appliance operation
  • Area: Monthly verification of release gear reset condition and hook attachment security
    Check: Monthly verification of release gear reset condition and hook attachment security
  • Area: Annual thorough examination of lifeboat structure, propulsion systems, maneuvering controls, and airtight door seals by competent certified personnel
    Check: Annual thorough examination of lifeboat structure, propulsion systems, maneuvering controls, and airtight door seals by competent certified personnel
  • Area: Annual inspection of ventilation system and air supply lines including CO2 bottles and sprinkler system (if applicable)
    Check: Annual inspection of ventilation system and air supply lines including CO2 bottles and sprinkler system (if applicable)
  • Area: Annual davit inspection including structural condition, wire rope condition, sheaves, and lubrication of moving parts
    Check: Annual davit inspection including structural condition, wire rope condition, sheaves, and lubrication of moving parts
  • Area: Five-yearly renewal of wire rope falls and load testing of on-load/off-load release gear at 1.1x rated capacity
    Check: Five-yearly renewal of wire rope falls and load testing of on-load/off-load release gear at 1.1x rated capacity
  • Area: Quarterly operational drills with assigned crew aboard to verify launching procedures and equipment readiness
    Check: Quarterly operational drills with assigned crew aboard to verify launching procedures and equipment readiness

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

Fassmer Maritime CLR-C 12.4
CLR-C 12.4 ✓ verified
Application
Totally enclosed compact lifeboat for cargo vessels
Common Failures & Inspection Points
  • Area: Weekly visual inspection of hull integrity, composite structure for cracks, and all seals for water tightness
    Check: Weekly visual inspection of hull integrity, composite structure for cracks, and all seals for water tightness
  • Area: Weekly engine start-up and run for minimum 3 minutes at operating temperature to verify propulsion system functionality
    Check: Weekly engine start-up and run for minimum 3 minutes at operating temperature to verify propulsion system functionality
  • Area: Monthly turn-out from stowed position without crew to test davit and launching appliance operation
    Check: Monthly turn-out from stowed position without crew to test davit and launching appliance operation
  • Area: Monthly verification of release gear reset condition and hook attachment security
    Check: Monthly verification of release gear reset condition and hook attachment security
  • Area: Annual thorough examination of lifeboat structure, propulsion systems, maneuvering controls, and airtight door seals by competent certified personnel
    Check: Annual thorough examination of lifeboat structure, propulsion systems, maneuvering controls, and airtight door seals by competent certified personnel
  • Area: Annual inspection of ventilation system and air supply lines including CO2 bottles and sprinkler system (if applicable)
    Check: Annual inspection of ventilation system and air supply lines including CO2 bottles and sprinkler system (if applicable)
  • Area: Annual davit inspection including structural condition, wire rope condition, sheaves, and lubrication of moving parts
    Check: Annual davit inspection including structural condition, wire rope condition, sheaves, and lubrication of moving parts
  • Area: Five-yearly renewal of wire rope falls and load testing of on-load/off-load release gear at 1.1x rated capacity
    Check: Five-yearly renewal of wire rope falls and load testing of on-load/off-load release gear at 1.1x rated capacity
  • Area: Quarterly operational drills with assigned crew aboard to verify launching procedures and equipment readiness
    Check: Quarterly operational drills with assigned crew aboard to verify launching procedures and equipment readiness

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

Fassmer Maritime CL 13.2
CL 13.2 ✓ verified
Application
Totally enclosed lifeboat for ships, commercial and offshore vessels
Common Failures & Inspection Points
  • Area: Weekly visual inspection of hull integrity, composite structure for cracks, and all seals for water tightness
    Check: Weekly visual inspection of hull integrity, composite structure for cracks, and all seals for water tightness
  • Area: Weekly engine start-up and run for minimum 3 minutes at operating temperature to verify propulsion system functionality
    Check: Weekly engine start-up and run for minimum 3 minutes at operating temperature to verify propulsion system functionality
  • Area: Monthly turn-out from stowed position without crew to test davit and launching appliance operation
    Check: Monthly turn-out from stowed position without crew to test davit and launching appliance operation
  • Area: Monthly verification of release gear reset condition and hook attachment security
    Check: Monthly verification of release gear reset condition and hook attachment security
  • Area: Annual thorough examination of lifeboat structure, propulsion systems, maneuvering controls, and airtight door seals by competent certified personnel
    Check: Annual thorough examination of lifeboat structure, propulsion systems, maneuvering controls, and airtight door seals by competent certified personnel
  • Area: Annual inspection of ventilation system and air supply lines including CO2 bottles and sprinkler system (if applicable)
    Check: Annual inspection of ventilation system and air supply lines including CO2 bottles and sprinkler system (if applicable)
  • Area: Annual davit inspection including structural condition, wire rope condition, sheaves, and lubrication of moving parts
    Check: Annual davit inspection including structural condition, wire rope condition, sheaves, and lubrication of moving parts
  • Area: Five-yearly renewal of wire rope falls and load testing of on-load/off-load release gear at 1.1x rated capacity
    Check: Five-yearly renewal of wire rope falls and load testing of on-load/off-load release gear at 1.1x rated capacity
  • Area: Quarterly operational drills with assigned crew aboard to verify launching procedures and equipment readiness
    Check: Quarterly operational drills with assigned crew aboard to verify launching procedures and equipment readiness

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

Fassmer Maritime CLX (Compact Lifeboat with Extra Large Capacity)
CLX (Compact Lifeboat with Extra Large Capacity) ✓ verified
Application
Totally enclosed lifeboat for large cruise ships and ferries with high capacity requirements
Common Failures & Inspection Points
  • Area: Weekly visual inspection of hull integrity, composite structure for cracks, and all seals for water tightness
    Check: Weekly visual inspection of hull integrity, composite structure for cracks, and all seals for water tightness
  • Area: Weekly engine start-up and run for minimum 3 minutes at operating temperature to verify propulsion system functionality
    Check: Weekly engine start-up and run for minimum 3 minutes at operating temperature to verify propulsion system functionality
  • Area: Monthly turn-out from stowed position without crew to test davit and launching appliance operation
    Check: Monthly turn-out from stowed position without crew to test davit and launching appliance operation
  • Area: Monthly verification of release gear reset condition and hook attachment security
    Check: Monthly verification of release gear reset condition and hook attachment security
  • Area: Annual thorough examination of lifeboat structure, propulsion systems, maneuvering controls, and airtight door seals by competent certified personnel
    Check: Annual thorough examination of lifeboat structure, propulsion systems, maneuvering controls, and airtight door seals by competent certified personnel
  • Area: Annual inspection of ventilation system and air supply lines including CO2 bottles and sprinkler system (if applicable)
    Check: Annual inspection of ventilation system and air supply lines including CO2 bottles and sprinkler system (if applicable)
  • Area: Annual davit inspection including structural condition, wire rope condition, sheaves, and lubrication of moving parts
    Check: Annual davit inspection including structural condition, wire rope condition, sheaves, and lubrication of moving parts
  • Area: Five-yearly renewal of wire rope falls and load testing of on-load/off-load release gear at 1.1x rated capacity
    Check: Five-yearly renewal of wire rope falls and load testing of on-load/off-load release gear at 1.1x rated capacity
  • Area: Quarterly operational drills with assigned crew aboard to verify launching procedures and equipment readiness
    Check: Quarterly operational drills with assigned crew aboard to verify launching procedures and equipment readiness

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

Fassmer Maritime CFL-C 49 (Freefall Lifeboat)
CFL-C 49 (Freefall Lifeboat) ✓ verified
Application
Totally enclosed freefall lifeboat for ships and offshore platforms
Common Failures & Inspection Points
  • Area: Weekly visual inspection of hull integrity, composite structure for cracks, and all seals for water tightness
    Check: Weekly visual inspection of hull integrity, composite structure for cracks, and all seals for water tightness
  • Area: Weekly engine start-up and run for minimum 3 minutes at operating temperature to verify propulsion system functionality
    Check: Weekly engine start-up and run for minimum 3 minutes at operating temperature to verify propulsion system functionality
  • Area: Monthly turn-out from stowed position without crew to test davit and launching appliance operation
    Check: Monthly turn-out from stowed position without crew to test davit and launching appliance operation
  • Area: Monthly verification of release gear reset condition and hook attachment security
    Check: Monthly verification of release gear reset condition and hook attachment security
  • Area: Annual thorough examination of lifeboat structure, propulsion systems, maneuvering controls, and airtight door seals by competent certified personnel
    Check: Annual thorough examination of lifeboat structure, propulsion systems, maneuvering controls, and airtight door seals by competent certified personnel
  • Area: Annual inspection of ventilation system and air supply lines including CO2 bottles and sprinkler system (if applicable)
    Check: Annual inspection of ventilation system and air supply lines including CO2 bottles and sprinkler system (if applicable)
  • Area: Annual davit inspection including structural condition, wire rope condition, sheaves, and lubrication of moving parts
    Check: Annual davit inspection including structural condition, wire rope condition, sheaves, and lubrication of moving parts
  • Area: Five-yearly renewal of wire rope falls and load testing of on-load/off-load release gear at 1.1x rated capacity
    Check: Five-yearly renewal of wire rope falls and load testing of on-load/off-load release gear at 1.1x rated capacity
  • Area: Quarterly operational drills with assigned crew aboard to verify launching procedures and equipment readiness
    Check: Quarterly operational drills with assigned crew aboard to verify launching procedures and equipment readiness

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

Fassmer Maritime CFL-C 66 (Freefall Lifeboat)
CFL-C 66 (Freefall Lifeboat) ✓ verified
Application
Totally enclosed freefall lifeboat for ships and offshore platforms
Common Failures & Inspection Points
  • Area: Weekly visual inspection of hull integrity, composite structure for cracks, and all seals for water tightness
    Check: Weekly visual inspection of hull integrity, composite structure for cracks, and all seals for water tightness
  • Area: Weekly engine start-up and run for minimum 3 minutes at operating temperature to verify propulsion system functionality
    Check: Weekly engine start-up and run for minimum 3 minutes at operating temperature to verify propulsion system functionality
  • Area: Monthly turn-out from stowed position without crew to test davit and launching appliance operation
    Check: Monthly turn-out from stowed position without crew to test davit and launching appliance operation
  • Area: Monthly verification of release gear reset condition and hook attachment security
    Check: Monthly verification of release gear reset condition and hook attachment security
  • Area: Annual thorough examination of lifeboat structure, propulsion systems, maneuvering controls, and airtight door seals by competent certified personnel
    Check: Annual thorough examination of lifeboat structure, propulsion systems, maneuvering controls, and airtight door seals by competent certified personnel
  • Area: Annual inspection of ventilation system and air supply lines including CO2 bottles and sprinkler system (if applicable)
    Check: Annual inspection of ventilation system and air supply lines including CO2 bottles and sprinkler system (if applicable)
  • Area: Annual davit inspection including structural condition, wire rope condition, sheaves, and lubrication of moving parts
    Check: Annual davit inspection including structural condition, wire rope condition, sheaves, and lubrication of moving parts
  • Area: Five-yearly renewal of wire rope falls and load testing of on-load/off-load release gear at 1.1x rated capacity
    Check: Five-yearly renewal of wire rope falls and load testing of on-load/off-load release gear at 1.1x rated capacity
  • Area: Quarterly operational drills with assigned crew aboard to verify launching procedures and equipment readiness
    Check: Quarterly operational drills with assigned crew aboard to verify launching procedures and equipment readiness

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

Fassmer Maritime CFL-C 72 (Freefall Lifeboat)
CFL-C 72 (Freefall Lifeboat) ✓ verified
Application
Totally enclosed freefall lifeboat for ships and offshore platforms
Common Failures & Inspection Points
  • Area: Weekly visual inspection of hull integrity, composite structure for cracks, and all seals for water tightness
    Check: Weekly visual inspection of hull integrity, composite structure for cracks, and all seals for water tightness
  • Area: Weekly engine start-up and run for minimum 3 minutes at operating temperature to verify propulsion system functionality
    Check: Weekly engine start-up and run for minimum 3 minutes at operating temperature to verify propulsion system functionality
  • Area: Monthly turn-out from stowed position without crew to test davit and launching appliance operation
    Check: Monthly turn-out from stowed position without crew to test davit and launching appliance operation
  • Area: Monthly verification of release gear reset condition and hook attachment security
    Check: Monthly verification of release gear reset condition and hook attachment security
  • Area: Annual thorough examination of lifeboat structure, propulsion systems, maneuvering controls, and airtight door seals by competent certified personnel
    Check: Annual thorough examination of lifeboat structure, propulsion systems, maneuvering controls, and airtight door seals by competent certified personnel
  • Area: Annual inspection of ventilation system and air supply lines including CO2 bottles and sprinkler system (if applicable)
    Check: Annual inspection of ventilation system and air supply lines including CO2 bottles and sprinkler system (if applicable)
  • Area: Annual davit inspection including structural condition, wire rope condition, sheaves, and lubrication of moving parts
    Check: Annual davit inspection including structural condition, wire rope condition, sheaves, and lubrication of moving parts
  • Area: Five-yearly renewal of wire rope falls and load testing of on-load/off-load release gear at 1.1x rated capacity
    Check: Five-yearly renewal of wire rope falls and load testing of on-load/off-load release gear at 1.1x rated capacity
  • Area: Quarterly operational drills with assigned crew aboard to verify launching procedures and equipment readiness
    Check: Quarterly operational drills with assigned crew aboard to verify launching procedures and equipment readiness

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

Fassmer Maritime CFL-C 77 (Freefall Lifeboat)
CFL-C 77 (Freefall Lifeboat) ✓ verified
Application
Totally enclosed freefall lifeboat for ships and offshore platforms
Common Failures & Inspection Points
  • Area: Weekly visual inspection of hull integrity, composite structure for cracks, and all seals for water tightness
    Check: Weekly visual inspection of hull integrity, composite structure for cracks, and all seals for water tightness
  • Area: Weekly engine start-up and run for minimum 3 minutes at operating temperature to verify propulsion system functionality
    Check: Weekly engine start-up and run for minimum 3 minutes at operating temperature to verify propulsion system functionality
  • Area: Monthly turn-out from stowed position without crew to test davit and launching appliance operation
    Check: Monthly turn-out from stowed position without crew to test davit and launching appliance operation
  • Area: Monthly verification of release gear reset condition and hook attachment security
    Check: Monthly verification of release gear reset condition and hook attachment security
  • Area: Annual thorough examination of lifeboat structure, propulsion systems, maneuvering controls, and airtight door seals by competent certified personnel
    Check: Annual thorough examination of lifeboat structure, propulsion systems, maneuvering controls, and airtight door seals by competent certified personnel
  • Area: Annual inspection of ventilation system and air supply lines including CO2 bottles and sprinkler system (if applicable)
    Check: Annual inspection of ventilation system and air supply lines including CO2 bottles and sprinkler system (if applicable)
  • Area: Annual davit inspection including structural condition, wire rope condition, sheaves, and lubrication of moving parts
    Check: Annual davit inspection including structural condition, wire rope condition, sheaves, and lubrication of moving parts
  • Area: Five-yearly renewal of wire rope falls and load testing of on-load/off-load release gear at 1.1x rated capacity
    Check: Five-yearly renewal of wire rope falls and load testing of on-load/off-load release gear at 1.1x rated capacity
  • Area: Quarterly operational drills with assigned crew aboard to verify launching procedures and equipment readiness
    Check: Quarterly operational drills with assigned crew aboard to verify launching procedures and equipment readiness

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

Fassmer Maritime CFL-C 83 (Freefall Lifeboat)
CFL-C 83 (Freefall Lifeboat) ✓ verified
Application
Totally enclosed freefall lifeboat for ships and offshore platforms
Common Failures & Inspection Points
  • Area: Weekly visual inspection of hull integrity, composite structure for cracks, and all seals for water tightness
    Check: Weekly visual inspection of hull integrity, composite structure for cracks, and all seals for water tightness
  • Area: Weekly engine start-up and run for minimum 3 minutes at operating temperature to verify propulsion system functionality
    Check: Weekly engine start-up and run for minimum 3 minutes at operating temperature to verify propulsion system functionality
  • Area: Monthly turn-out from stowed position without crew to test davit and launching appliance operation
    Check: Monthly turn-out from stowed position without crew to test davit and launching appliance operation
  • Area: Monthly verification of release gear reset condition and hook attachment security
    Check: Monthly verification of release gear reset condition and hook attachment security
  • Area: Annual thorough examination of lifeboat structure, propulsion systems, maneuvering controls, and airtight door seals by competent certified personnel
    Check: Annual thorough examination of lifeboat structure, propulsion systems, maneuvering controls, and airtight door seals by competent certified personnel
  • Area: Annual inspection of ventilation system and air supply lines including CO2 bottles and sprinkler system (if applicable)
    Check: Annual inspection of ventilation system and air supply lines including CO2 bottles and sprinkler system (if applicable)
  • Area: Annual davit inspection including structural condition, wire rope condition, sheaves, and lubrication of moving parts
    Check: Annual davit inspection including structural condition, wire rope condition, sheaves, and lubrication of moving parts
  • Area: Five-yearly renewal of wire rope falls and load testing of on-load/off-load release gear at 1.1x rated capacity
    Check: Five-yearly renewal of wire rope falls and load testing of on-load/off-load release gear at 1.1x rated capacity
  • Area: Quarterly operational drills with assigned crew aboard to verify launching procedures and equipment readiness
    Check: Quarterly operational drills with assigned crew aboard to verify launching procedures and equipment readiness

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

Ningbo New Marine Lifesaving Equipment Co., Ltd.

11 ✓ 11 verified
Ningbo New Marine Lifesaving Equipment Co., Ltd. NML50C
NML50C ✓ verified
Application
Rescue boat and totally enclosed lifeboat for tankers, dry cargo vessels, and offshore platforms
Common Failures & Inspection Points
  • Area: Hull integrity and GRP condition - check for cracks, delamination, osmotic blistering
    Check: Hull integrity and GRP condition - check for cracks, delamination, osmotic blistering
  • Area: Structural frame and internal stiffening members - inspect for corrosion and deformation
    Check: Structural frame and internal stiffening members - inspect for corrosion and deformation
  • Area: Hatch/door seals and closure mechanisms - verify watertight/weathertight integrity
    Check: Hatch/door seals and closure mechanisms - verify watertight/weathertight integrity
  • Area: Inboard diesel engine condition and fuel system - verify fuel filter cleanliness and tank integrity
    Check: Inboard diesel engine condition and fuel system - verify fuel filter cleanliness and tank integrity
  • Area: Launch and recovery davit compatibility - test winch brake operation
    Check: Launch and recovery davit compatibility - test winch brake operation
  • Area: Life-saving equipment quantity and accessibility - verify per SOLAS regulations (lifejackets, flares, first aid kits, signals)
    Check: Life-saving equipment quantity and accessibility - verify per SOLAS regulations (lifejackets, flares, first aid kits, signals)
  • Area: Interior ventilation and drainage systems - confirm clear drainage and functioning vents
    Check: Interior ventilation and drainage systems - confirm clear drainage and functioning vents
  • Area: Certification validity and GRP paint/coating condition - verify all SOLAS marking and decals
    Check: Certification validity and GRP paint/coating condition - verify all SOLAS marking and decals

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

Ningbo New Marine Lifesaving Equipment Co., Ltd. NM50C
NM50C ✓ verified
Application
Totally enclosed lifeboat (Common Type) for emergency evacuation
Common Failures & Inspection Points
  • Area: Hull integrity and GRP condition - check for cracks, delamination, osmotic blistering
    Check: Hull integrity and GRP condition - check for cracks, delamination, osmotic blistering
  • Area: Structural frame and internal stiffening members - inspect for corrosion and deformation
    Check: Structural frame and internal stiffening members - inspect for corrosion and deformation
  • Area: Hatch/door seals and closure mechanisms - verify watertight/weathertight integrity
    Check: Hatch/door seals and closure mechanisms - verify watertight/weathertight integrity
  • Area: Inboard diesel engine condition and fuel system - verify fuel filter cleanliness and tank integrity
    Check: Inboard diesel engine condition and fuel system - verify fuel filter cleanliness and tank integrity
  • Area: Launch and recovery davit compatibility - test winch brake operation
    Check: Launch and recovery davit compatibility - test winch brake operation
  • Area: Life-saving equipment quantity and accessibility - verify per SOLAS regulations (lifejackets, flares, first aid kits, signals)
    Check: Life-saving equipment quantity and accessibility - verify per SOLAS regulations (lifejackets, flares, first aid kits, signals)
  • Area: Interior ventilation and drainage systems - confirm clear drainage and functioning vents
    Check: Interior ventilation and drainage systems - confirm clear drainage and functioning vents
  • Area: Certification validity and GRP paint/coating condition - verify all SOLAS marking and decals
    Check: Certification validity and GRP paint/coating condition - verify all SOLAS marking and decals

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

Ningbo New Marine Lifesaving Equipment Co., Ltd. NM50F
NM50F ✓ verified
Application
Totally enclosed lifeboat (Fire-proof Type) for emergency evacuation
Common Failures & Inspection Points
  • Area: Hull integrity and GRP condition - check for cracks, delamination, osmotic blistering
    Check: Hull integrity and GRP condition - check for cracks, delamination, osmotic blistering
  • Area: Structural frame and internal stiffening members - inspect for corrosion and deformation
    Check: Structural frame and internal stiffening members - inspect for corrosion and deformation
  • Area: Hatch/door seals and closure mechanisms - verify watertight/weathertight integrity
    Check: Hatch/door seals and closure mechanisms - verify watertight/weathertight integrity
  • Area: Inboard diesel engine condition and fuel system - verify fuel filter cleanliness and tank integrity
    Check: Inboard diesel engine condition and fuel system - verify fuel filter cleanliness and tank integrity
  • Area: Launch and recovery davit compatibility - test winch brake operation
    Check: Launch and recovery davit compatibility - test winch brake operation
  • Area: Life-saving equipment quantity and accessibility - verify per SOLAS regulations (lifejackets, flares, first aid kits, signals)
    Check: Life-saving equipment quantity and accessibility - verify per SOLAS regulations (lifejackets, flares, first aid kits, signals)
  • Area: Interior ventilation and drainage systems - confirm clear drainage and functioning vents
    Check: Interior ventilation and drainage systems - confirm clear drainage and functioning vents
  • Area: Certification validity and GRP paint/coating condition - verify all SOLAS marking and decals
    Check: Certification validity and GRP paint/coating condition - verify all SOLAS marking and decals

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

Ningbo New Marine Lifesaving Equipment Co., Ltd. NM58C
NM58C ✓ verified
Application
Totally enclosed lifeboat (Common Type) for emergency evacuation
Common Failures & Inspection Points
  • Area: Hull integrity and GRP condition - check for cracks, delamination, osmotic blistering
    Check: Hull integrity and GRP condition - check for cracks, delamination, osmotic blistering
  • Area: Structural frame and internal stiffening members - inspect for corrosion and deformation
    Check: Structural frame and internal stiffening members - inspect for corrosion and deformation
  • Area: Hatch/door seals and closure mechanisms - verify watertight/weathertight integrity
    Check: Hatch/door seals and closure mechanisms - verify watertight/weathertight integrity
  • Area: Inboard diesel engine condition and fuel system - verify fuel filter cleanliness and tank integrity
    Check: Inboard diesel engine condition and fuel system - verify fuel filter cleanliness and tank integrity
  • Area: Launch and recovery davit compatibility - test winch brake operation
    Check: Launch and recovery davit compatibility - test winch brake operation
  • Area: Life-saving equipment quantity and accessibility - verify per SOLAS regulations (lifejackets, flares, first aid kits, signals)
    Check: Life-saving equipment quantity and accessibility - verify per SOLAS regulations (lifejackets, flares, first aid kits, signals)
  • Area: Interior ventilation and drainage systems - confirm clear drainage and functioning vents
    Check: Interior ventilation and drainage systems - confirm clear drainage and functioning vents
  • Area: Certification validity and GRP paint/coating condition - verify all SOLAS marking and decals
    Check: Certification validity and GRP paint/coating condition - verify all SOLAS marking and decals

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

Ningbo New Marine Lifesaving Equipment Co., Ltd. NM58F
NM58F ✓ verified
Application
Totally enclosed lifeboat (Fire-proof Type) for emergency evacuation
Common Failures & Inspection Points
  • Area: Hull integrity and GRP condition - check for cracks, delamination, osmotic blistering
    Check: Hull integrity and GRP condition - check for cracks, delamination, osmotic blistering
  • Area: Structural frame and internal stiffening members - inspect for corrosion and deformation
    Check: Structural frame and internal stiffening members - inspect for corrosion and deformation
  • Area: Hatch/door seals and closure mechanisms - verify watertight/weathertight integrity
    Check: Hatch/door seals and closure mechanisms - verify watertight/weathertight integrity
  • Area: Inboard diesel engine condition and fuel system - verify fuel filter cleanliness and tank integrity
    Check: Inboard diesel engine condition and fuel system - verify fuel filter cleanliness and tank integrity
  • Area: Launch and recovery davit compatibility - test winch brake operation
    Check: Launch and recovery davit compatibility - test winch brake operation
  • Area: Life-saving equipment quantity and accessibility - verify per SOLAS regulations (lifejackets, flares, first aid kits, signals)
    Check: Life-saving equipment quantity and accessibility - verify per SOLAS regulations (lifejackets, flares, first aid kits, signals)
  • Area: Interior ventilation and drainage systems - confirm clear drainage and functioning vents
    Check: Interior ventilation and drainage systems - confirm clear drainage and functioning vents
  • Area: Certification validity and GRP paint/coating condition - verify all SOLAS marking and decals
    Check: Certification validity and GRP paint/coating condition - verify all SOLAS marking and decals

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

Ningbo New Marine Lifesaving Equipment Co., Ltd. NM65C
NM65C ✓ verified
Application
Totally enclosed lifeboat (Common Type) for emergency evacuation
Common Failures & Inspection Points
  • Area: Hull integrity and GRP condition - check for cracks, delamination, osmotic blistering
    Check: Hull integrity and GRP condition - check for cracks, delamination, osmotic blistering
  • Area: Structural frame and internal stiffening members - inspect for corrosion and deformation
    Check: Structural frame and internal stiffening members - inspect for corrosion and deformation
  • Area: Hatch/door seals and closure mechanisms - verify watertight/weathertight integrity
    Check: Hatch/door seals and closure mechanisms - verify watertight/weathertight integrity
  • Area: Inboard diesel engine condition and fuel system - verify fuel filter cleanliness and tank integrity
    Check: Inboard diesel engine condition and fuel system - verify fuel filter cleanliness and tank integrity
  • Area: Launch and recovery davit compatibility - test winch brake operation
    Check: Launch and recovery davit compatibility - test winch brake operation
  • Area: Life-saving equipment quantity and accessibility - verify per SOLAS regulations (lifejackets, flares, first aid kits, signals)
    Check: Life-saving equipment quantity and accessibility - verify per SOLAS regulations (lifejackets, flares, first aid kits, signals)
  • Area: Interior ventilation and drainage systems - confirm clear drainage and functioning vents
    Check: Interior ventilation and drainage systems - confirm clear drainage and functioning vents
  • Area: Certification validity and GRP paint/coating condition - verify all SOLAS marking and decals
    Check: Certification validity and GRP paint/coating condition - verify all SOLAS marking and decals

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

Ningbo New Marine Lifesaving Equipment Co., Ltd. NM65F
NM65F ✓ verified
Application
Totally enclosed lifeboat (Fire-proof Type) for emergency evacuation
Common Failures & Inspection Points
  • Area: Hull integrity and GRP condition - check for cracks, delamination, osmotic blistering
    Check: Hull integrity and GRP condition - check for cracks, delamination, osmotic blistering
  • Area: Structural frame and internal stiffening members - inspect for corrosion and deformation
    Check: Structural frame and internal stiffening members - inspect for corrosion and deformation
  • Area: Hatch/door seals and closure mechanisms - verify watertight/weathertight integrity
    Check: Hatch/door seals and closure mechanisms - verify watertight/weathertight integrity
  • Area: Inboard diesel engine condition and fuel system - verify fuel filter cleanliness and tank integrity
    Check: Inboard diesel engine condition and fuel system - verify fuel filter cleanliness and tank integrity
  • Area: Launch and recovery davit compatibility - test winch brake operation
    Check: Launch and recovery davit compatibility - test winch brake operation
  • Area: Life-saving equipment quantity and accessibility - verify per SOLAS regulations (lifejackets, flares, first aid kits, signals)
    Check: Life-saving equipment quantity and accessibility - verify per SOLAS regulations (lifejackets, flares, first aid kits, signals)
  • Area: Interior ventilation and drainage systems - confirm clear drainage and functioning vents
    Check: Interior ventilation and drainage systems - confirm clear drainage and functioning vents
  • Area: Certification validity and GRP paint/coating condition - verify all SOLAS marking and decals
    Check: Certification validity and GRP paint/coating condition - verify all SOLAS marking and decals

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

Ningbo New Marine Lifesaving Equipment Co., Ltd. NM75C
NM75C ✓ verified
Application
Totally enclosed lifeboat (Common Type) for emergency evacuation
Common Failures & Inspection Points
  • Area: Hull integrity and GRP condition - check for cracks, delamination, osmotic blistering
    Check: Hull integrity and GRP condition - check for cracks, delamination, osmotic blistering
  • Area: Structural frame and internal stiffening members - inspect for corrosion and deformation
    Check: Structural frame and internal stiffening members - inspect for corrosion and deformation
  • Area: Hatch/door seals and closure mechanisms - verify watertight/weathertight integrity
    Check: Hatch/door seals and closure mechanisms - verify watertight/weathertight integrity
  • Area: Inboard diesel engine condition and fuel system - verify fuel filter cleanliness and tank integrity
    Check: Inboard diesel engine condition and fuel system - verify fuel filter cleanliness and tank integrity
  • Area: Launch and recovery davit compatibility - test winch brake operation
    Check: Launch and recovery davit compatibility - test winch brake operation
  • Area: Life-saving equipment quantity and accessibility - verify per SOLAS regulations (lifejackets, flares, first aid kits, signals)
    Check: Life-saving equipment quantity and accessibility - verify per SOLAS regulations (lifejackets, flares, first aid kits, signals)
  • Area: Interior ventilation and drainage systems - confirm clear drainage and functioning vents
    Check: Interior ventilation and drainage systems - confirm clear drainage and functioning vents
  • Area: Certification validity and GRP paint/coating condition - verify all SOLAS marking and decals
    Check: Certification validity and GRP paint/coating condition - verify all SOLAS marking and decals

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

Ningbo New Marine Lifesaving Equipment Co., Ltd. NM75F
NM75F ✓ verified
Application
Totally enclosed lifeboat (Fire-proof Type) for emergency evacuation
Common Failures & Inspection Points
  • Area: Hull integrity and GRP condition - check for cracks, delamination, osmotic blistering
    Check: Hull integrity and GRP condition - check for cracks, delamination, osmotic blistering
  • Area: Structural frame and internal stiffening members - inspect for corrosion and deformation
    Check: Structural frame and internal stiffening members - inspect for corrosion and deformation
  • Area: Hatch/door seals and closure mechanisms - verify watertight/weathertight integrity
    Check: Hatch/door seals and closure mechanisms - verify watertight/weathertight integrity
  • Area: Inboard diesel engine condition and fuel system - verify fuel filter cleanliness and tank integrity
    Check: Inboard diesel engine condition and fuel system - verify fuel filter cleanliness and tank integrity
  • Area: Launch and recovery davit compatibility - test winch brake operation
    Check: Launch and recovery davit compatibility - test winch brake operation
  • Area: Life-saving equipment quantity and accessibility - verify per SOLAS regulations (lifejackets, flares, first aid kits, signals)
    Check: Life-saving equipment quantity and accessibility - verify per SOLAS regulations (lifejackets, flares, first aid kits, signals)
  • Area: Interior ventilation and drainage systems - confirm clear drainage and functioning vents
    Check: Interior ventilation and drainage systems - confirm clear drainage and functioning vents
  • Area: Certification validity and GRP paint/coating condition - verify all SOLAS marking and decals
    Check: Certification validity and GRP paint/coating condition - verify all SOLAS marking and decals

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

Ningbo New Marine Lifesaving Equipment Co., Ltd. NM85C
NM85C ✓ verified
Application
Totally enclosed lifeboat (Common Type) for emergency evacuation
Common Failures & Inspection Points
  • Area: Hull integrity and GRP condition - check for cracks, delamination, osmotic blistering
    Check: Hull integrity and GRP condition - check for cracks, delamination, osmotic blistering
  • Area: Structural frame and internal stiffening members - inspect for corrosion and deformation
    Check: Structural frame and internal stiffening members - inspect for corrosion and deformation
  • Area: Hatch/door seals and closure mechanisms - verify watertight/weathertight integrity
    Check: Hatch/door seals and closure mechanisms - verify watertight/weathertight integrity
  • Area: Inboard diesel engine condition and fuel system - verify fuel filter cleanliness and tank integrity
    Check: Inboard diesel engine condition and fuel system - verify fuel filter cleanliness and tank integrity
  • Area: Launch and recovery davit compatibility - test winch brake operation
    Check: Launch and recovery davit compatibility - test winch brake operation
  • Area: Life-saving equipment quantity and accessibility - verify per SOLAS regulations (lifejackets, flares, first aid kits, signals)
    Check: Life-saving equipment quantity and accessibility - verify per SOLAS regulations (lifejackets, flares, first aid kits, signals)
  • Area: Interior ventilation and drainage systems - confirm clear drainage and functioning vents
    Check: Interior ventilation and drainage systems - confirm clear drainage and functioning vents
  • Area: Certification validity and GRP paint/coating condition - verify all SOLAS marking and decals
    Check: Certification validity and GRP paint/coating condition - verify all SOLAS marking and decals

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

Ningbo New Marine Lifesaving Equipment Co., Ltd. NM85F
NM85F ✓ verified
Application
Totally enclosed lifeboat (Fire-proof Type) for emergency evacuation
Common Failures & Inspection Points
  • Area: Hull integrity and GRP condition - check for cracks, delamination, osmotic blistering
    Check: Hull integrity and GRP condition - check for cracks, delamination, osmotic blistering
  • Area: Structural frame and internal stiffening members - inspect for corrosion and deformation
    Check: Structural frame and internal stiffening members - inspect for corrosion and deformation
  • Area: Hatch/door seals and closure mechanisms - verify watertight/weathertight integrity
    Check: Hatch/door seals and closure mechanisms - verify watertight/weathertight integrity
  • Area: Inboard diesel engine condition and fuel system - verify fuel filter cleanliness and tank integrity
    Check: Inboard diesel engine condition and fuel system - verify fuel filter cleanliness and tank integrity
  • Area: Launch and recovery davit compatibility - test winch brake operation
    Check: Launch and recovery davit compatibility - test winch brake operation
  • Area: Life-saving equipment quantity and accessibility - verify per SOLAS regulations (lifejackets, flares, first aid kits, signals)
    Check: Life-saving equipment quantity and accessibility - verify per SOLAS regulations (lifejackets, flares, first aid kits, signals)
  • Area: Interior ventilation and drainage systems - confirm clear drainage and functioning vents
    Check: Interior ventilation and drainage systems - confirm clear drainage and functioning vents
  • Area: Certification validity and GRP paint/coating condition - verify all SOLAS marking and decals
    Check: Certification validity and GRP paint/coating condition - verify all SOLAS marking and decals

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

Norsafe

10 ✓ 10 verified
Norsafe JYN-50 MKI
JYN-50 MKI ✓ verified
Application
Davit-launched totally enclosed lifeboat (TELB) for commercial shipping
Common Failures & Inspection Points
  • Area: Visual inspection of hull, superstructure and buoyant tanks for cracks, corrosion, deformation, or fire damage; condition of fire-retardant GRP material
    Check: Visual inspection of hull, superstructure and buoyant tanks for cracks, corrosion, deformation, or fire damage; condition of fire-retardant GRP material
  • Area: Engine propulsion system functionality test (minimum 3-minute run); fuel system integrity and emergency engine start capability
    Check: Engine propulsion system functionality test (minimum 3-minute run); fuel system integrity and emergency engine start capability
  • Area: Airtight seals and hatch integrity; condition and operation of all doors, hatches, and ventilation systems per MSC.535(107)/MSC.559(108)
    Check: Airtight seals and hatch integrity; condition and operation of all doors, hatches, and ventilation systems per MSC.535(107)/MSC.559(108)
  • Area: On-load and off-load release gear functionality; annual dynamic load testing at 1.1x maximum loaded weight; certification of hook release mechanisms
    Check: On-load and off-load release gear functionality; annual dynamic load testing at 1.1x maximum loaded weight; certification of hook release mechanisms
  • Area: Self-righting mechanism operation verification (must self-right within 15 seconds if capsized); positive stability checks up to 180 degrees
    Check: Self-righting mechanism operation verification (must self-right within 15 seconds if capsized); positive stability checks up to 180 degrees
  • Area: Compressed air supply systems and breathing apparatus; verification of minimum 10+ minutes occupancy air capacity
    Check: Compressed air supply systems and breathing apparatus; verification of minimum 10+ minutes occupancy air capacity
  • Area: External sprinkler/water spray systems and thermal insulation condition; fire-resistant material integrity
    Check: External sprinkler/water spray systems and thermal insulation condition; fire-resistant material integrity
  • Area: Safety equipment verification: life jackets, personal protective equipment, harnesses, shock-absorbing seats, ladder condition
    Check: Safety equipment verification: life jackets, personal protective equipment, harnesses, shock-absorbing seats, ladder condition

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

Norsafe JYN-65 MKI
JYN-65 MKI ✓ verified
Application
Davit-launched totally enclosed lifeboat (TELB) for commercial shipping
Common Failures & Inspection Points
  • Area: Visual inspection of hull, superstructure and buoyant tanks for cracks, corrosion, deformation, or fire damage; condition of fire-retardant GRP material
    Check: Visual inspection of hull, superstructure and buoyant tanks for cracks, corrosion, deformation, or fire damage; condition of fire-retardant GRP material
  • Area: Engine propulsion system functionality test (minimum 3-minute run); fuel system integrity and emergency engine start capability
    Check: Engine propulsion system functionality test (minimum 3-minute run); fuel system integrity and emergency engine start capability
  • Area: Airtight seals and hatch integrity; condition and operation of all doors, hatches, and ventilation systems per MSC.535(107)/MSC.559(108)
    Check: Airtight seals and hatch integrity; condition and operation of all doors, hatches, and ventilation systems per MSC.535(107)/MSC.559(108)
  • Area: On-load and off-load release gear functionality; annual dynamic load testing at 1.1x maximum loaded weight; certification of hook release mechanisms
    Check: On-load and off-load release gear functionality; annual dynamic load testing at 1.1x maximum loaded weight; certification of hook release mechanisms
  • Area: Self-righting mechanism operation verification (must self-right within 15 seconds if capsized); positive stability checks up to 180 degrees
    Check: Self-righting mechanism operation verification (must self-right within 15 seconds if capsized); positive stability checks up to 180 degrees
  • Area: Compressed air supply systems and breathing apparatus; verification of minimum 10+ minutes occupancy air capacity
    Check: Compressed air supply systems and breathing apparatus; verification of minimum 10+ minutes occupancy air capacity
  • Area: External sprinkler/water spray systems and thermal insulation condition; fire-resistant material integrity
    Check: External sprinkler/water spray systems and thermal insulation condition; fire-resistant material integrity
  • Area: Safety equipment verification: life jackets, personal protective equipment, harnesses, shock-absorbing seats, ladder condition
    Check: Safety equipment verification: life jackets, personal protective equipment, harnesses, shock-absorbing seats, ladder condition

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

Norsafe JYN-74 MKI
JYN-74 MKI ✓ verified
Application
Davit-launched totally enclosed lifeboat (TELB) for commercial shipping
Common Failures & Inspection Points
  • Area: Visual inspection of hull, superstructure and buoyant tanks for cracks, corrosion, deformation, or fire damage; condition of fire-retardant GRP material
    Check: Visual inspection of hull, superstructure and buoyant tanks for cracks, corrosion, deformation, or fire damage; condition of fire-retardant GRP material
  • Area: Engine propulsion system functionality test (minimum 3-minute run); fuel system integrity and emergency engine start capability
    Check: Engine propulsion system functionality test (minimum 3-minute run); fuel system integrity and emergency engine start capability
  • Area: Airtight seals and hatch integrity; condition and operation of all doors, hatches, and ventilation systems per MSC.535(107)/MSC.559(108)
    Check: Airtight seals and hatch integrity; condition and operation of all doors, hatches, and ventilation systems per MSC.535(107)/MSC.559(108)
  • Area: On-load and off-load release gear functionality; annual dynamic load testing at 1.1x maximum loaded weight; certification of hook release mechanisms
    Check: On-load and off-load release gear functionality; annual dynamic load testing at 1.1x maximum loaded weight; certification of hook release mechanisms
  • Area: Self-righting mechanism operation verification (must self-right within 15 seconds if capsized); positive stability checks up to 180 degrees
    Check: Self-righting mechanism operation verification (must self-right within 15 seconds if capsized); positive stability checks up to 180 degrees
  • Area: Compressed air supply systems and breathing apparatus; verification of minimum 10+ minutes occupancy air capacity
    Check: Compressed air supply systems and breathing apparatus; verification of minimum 10+ minutes occupancy air capacity
  • Area: External sprinkler/water spray systems and thermal insulation condition; fire-resistant material integrity
    Check: External sprinkler/water spray systems and thermal insulation condition; fire-resistant material integrity
  • Area: Safety equipment verification: life jackets, personal protective equipment, harnesses, shock-absorbing seats, ladder condition
    Check: Safety equipment verification: life jackets, personal protective equipment, harnesses, shock-absorbing seats, ladder condition

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

Norsafe JYN-75 MKI
JYN-75 MKI ✓ verified
Application
Davit-launched totally enclosed lifeboat (TELB) for commercial shipping
Common Failures & Inspection Points
  • Area: Visual inspection of hull, superstructure and buoyant tanks for cracks, corrosion, deformation, or fire damage; condition of fire-retardant GRP material
    Check: Visual inspection of hull, superstructure and buoyant tanks for cracks, corrosion, deformation, or fire damage; condition of fire-retardant GRP material
  • Area: Engine propulsion system functionality test (minimum 3-minute run); fuel system integrity and emergency engine start capability
    Check: Engine propulsion system functionality test (minimum 3-minute run); fuel system integrity and emergency engine start capability
  • Area: Airtight seals and hatch integrity; condition and operation of all doors, hatches, and ventilation systems per MSC.535(107)/MSC.559(108)
    Check: Airtight seals and hatch integrity; condition and operation of all doors, hatches, and ventilation systems per MSC.535(107)/MSC.559(108)
  • Area: On-load and off-load release gear functionality; annual dynamic load testing at 1.1x maximum loaded weight; certification of hook release mechanisms
    Check: On-load and off-load release gear functionality; annual dynamic load testing at 1.1x maximum loaded weight; certification of hook release mechanisms
  • Area: Self-righting mechanism operation verification (must self-right within 15 seconds if capsized); positive stability checks up to 180 degrees
    Check: Self-righting mechanism operation verification (must self-right within 15 seconds if capsized); positive stability checks up to 180 degrees
  • Area: Compressed air supply systems and breathing apparatus; verification of minimum 10+ minutes occupancy air capacity
    Check: Compressed air supply systems and breathing apparatus; verification of minimum 10+ minutes occupancy air capacity
  • Area: External sprinkler/water spray systems and thermal insulation condition; fire-resistant material integrity
    Check: External sprinkler/water spray systems and thermal insulation condition; fire-resistant material integrity
  • Area: Safety equipment verification: life jackets, personal protective equipment, harnesses, shock-absorbing seats, ladder condition
    Check: Safety equipment verification: life jackets, personal protective equipment, harnesses, shock-absorbing seats, ladder condition

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

Norsafe JYN-80 MKI
JYN-80 MKI ✓ verified
Application
Davit-launched totally enclosed lifeboat (TELB) for commercial shipping
Common Failures & Inspection Points
  • Area: Visual inspection of hull, superstructure and buoyant tanks for cracks, corrosion, deformation, or fire damage; condition of fire-retardant GRP material
    Check: Visual inspection of hull, superstructure and buoyant tanks for cracks, corrosion, deformation, or fire damage; condition of fire-retardant GRP material
  • Area: Engine propulsion system functionality test (minimum 3-minute run); fuel system integrity and emergency engine start capability
    Check: Engine propulsion system functionality test (minimum 3-minute run); fuel system integrity and emergency engine start capability
  • Area: Airtight seals and hatch integrity; condition and operation of all doors, hatches, and ventilation systems per MSC.535(107)/MSC.559(108)
    Check: Airtight seals and hatch integrity; condition and operation of all doors, hatches, and ventilation systems per MSC.535(107)/MSC.559(108)
  • Area: On-load and off-load release gear functionality; annual dynamic load testing at 1.1x maximum loaded weight; certification of hook release mechanisms
    Check: On-load and off-load release gear functionality; annual dynamic load testing at 1.1x maximum loaded weight; certification of hook release mechanisms
  • Area: Self-righting mechanism operation verification (must self-right within 15 seconds if capsized); positive stability checks up to 180 degrees
    Check: Self-righting mechanism operation verification (must self-right within 15 seconds if capsized); positive stability checks up to 180 degrees
  • Area: Compressed air supply systems and breathing apparatus; verification of minimum 10+ minutes occupancy air capacity
    Check: Compressed air supply systems and breathing apparatus; verification of minimum 10+ minutes occupancy air capacity
  • Area: External sprinkler/water spray systems and thermal insulation condition; fire-resistant material integrity
    Check: External sprinkler/water spray systems and thermal insulation condition; fire-resistant material integrity
  • Area: Safety equipment verification: life jackets, personal protective equipment, harnesses, shock-absorbing seats, ladder condition
    Check: Safety equipment verification: life jackets, personal protective equipment, harnesses, shock-absorbing seats, ladder condition

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

Norsafe JYN-100 MKI
JYN-100 MKI ✓ verified
Application
Davit-launched totally enclosed lifeboat (TELB) for commercial shipping
Common Failures & Inspection Points
  • Area: Visual inspection of hull, superstructure and buoyant tanks for cracks, corrosion, deformation, or fire damage; condition of fire-retardant GRP material
    Check: Visual inspection of hull, superstructure and buoyant tanks for cracks, corrosion, deformation, or fire damage; condition of fire-retardant GRP material
  • Area: Engine propulsion system functionality test (minimum 3-minute run); fuel system integrity and emergency engine start capability
    Check: Engine propulsion system functionality test (minimum 3-minute run); fuel system integrity and emergency engine start capability
  • Area: Airtight seals and hatch integrity; condition and operation of all doors, hatches, and ventilation systems per MSC.535(107)/MSC.559(108)
    Check: Airtight seals and hatch integrity; condition and operation of all doors, hatches, and ventilation systems per MSC.535(107)/MSC.559(108)
  • Area: On-load and off-load release gear functionality; annual dynamic load testing at 1.1x maximum loaded weight; certification of hook release mechanisms
    Check: On-load and off-load release gear functionality; annual dynamic load testing at 1.1x maximum loaded weight; certification of hook release mechanisms
  • Area: Self-righting mechanism operation verification (must self-right within 15 seconds if capsized); positive stability checks up to 180 degrees
    Check: Self-righting mechanism operation verification (must self-right within 15 seconds if capsized); positive stability checks up to 180 degrees
  • Area: Compressed air supply systems and breathing apparatus; verification of minimum 10+ minutes occupancy air capacity
    Check: Compressed air supply systems and breathing apparatus; verification of minimum 10+ minutes occupancy air capacity
  • Area: External sprinkler/water spray systems and thermal insulation condition; fire-resistant material integrity
    Check: External sprinkler/water spray systems and thermal insulation condition; fire-resistant material integrity
  • Area: Safety equipment verification: life jackets, personal protective equipment, harnesses, shock-absorbing seats, ladder condition
    Check: Safety equipment verification: life jackets, personal protective equipment, harnesses, shock-absorbing seats, ladder condition

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

Norsafe JYN-115 MKI
JYN-115 MKI ✓ verified
Application
Davit-launched totally enclosed lifeboat (TELB) for large commercial vessels and offshore installations
Common Failures & Inspection Points
  • Area: Visual inspection of hull, superstructure and buoyant tanks for cracks, corrosion, deformation, or fire damage; condition of fire-retardant GRP material
    Check: Visual inspection of hull, superstructure and buoyant tanks for cracks, corrosion, deformation, or fire damage; condition of fire-retardant GRP material
  • Area: Engine propulsion system functionality test (minimum 3-minute run); fuel system integrity and emergency engine start capability
    Check: Engine propulsion system functionality test (minimum 3-minute run); fuel system integrity and emergency engine start capability
  • Area: Airtight seals and hatch integrity; condition and operation of all doors, hatches, and ventilation systems per MSC.535(107)/MSC.559(108)
    Check: Airtight seals and hatch integrity; condition and operation of all doors, hatches, and ventilation systems per MSC.535(107)/MSC.559(108)
  • Area: On-load and off-load release gear functionality; annual dynamic load testing at 1.1x maximum loaded weight; certification of hook release mechanisms
    Check: On-load and off-load release gear functionality; annual dynamic load testing at 1.1x maximum loaded weight; certification of hook release mechanisms
  • Area: Self-righting mechanism operation verification (must self-right within 15 seconds if capsized); positive stability checks up to 180 degrees
    Check: Self-righting mechanism operation verification (must self-right within 15 seconds if capsized); positive stability checks up to 180 degrees
  • Area: Compressed air supply systems and breathing apparatus; verification of minimum 10+ minutes occupancy air capacity
    Check: Compressed air supply systems and breathing apparatus; verification of minimum 10+ minutes occupancy air capacity
  • Area: External sprinkler/water spray systems and thermal insulation condition; fire-resistant material integrity
    Check: External sprinkler/water spray systems and thermal insulation condition; fire-resistant material integrity
  • Area: Safety equipment verification: life jackets, personal protective equipment, harnesses, shock-absorbing seats, ladder condition
    Check: Safety equipment verification: life jackets, personal protective equipment, harnesses, shock-absorbing seats, ladder condition

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

Norsafe MIRIAM 8.5 MKI
MIRIAM 8.5 MKI ✓ verified
Application
Davit-launched totally enclosed lifeboat (TELB) for commercial shipping and offshore
Common Failures & Inspection Points
  • Area: Visual inspection of hull, superstructure and buoyant tanks for cracks, corrosion, deformation, or fire damage; condition of fire-retardant GRP material
    Check: Visual inspection of hull, superstructure and buoyant tanks for cracks, corrosion, deformation, or fire damage; condition of fire-retardant GRP material
  • Area: Engine propulsion system functionality test (minimum 3-minute run); fuel system integrity and emergency engine start capability
    Check: Engine propulsion system functionality test (minimum 3-minute run); fuel system integrity and emergency engine start capability
  • Area: Airtight seals and hatch integrity; condition and operation of all doors, hatches, and ventilation systems per MSC.535(107)/MSC.559(108)
    Check: Airtight seals and hatch integrity; condition and operation of all doors, hatches, and ventilation systems per MSC.535(107)/MSC.559(108)
  • Area: On-load and off-load release gear functionality; annual dynamic load testing at 1.1x maximum loaded weight; certification of hook release mechanisms
    Check: On-load and off-load release gear functionality; annual dynamic load testing at 1.1x maximum loaded weight; certification of hook release mechanisms
  • Area: Self-righting mechanism operation verification (must self-right within 15 seconds if capsized); positive stability checks up to 180 degrees
    Check: Self-righting mechanism operation verification (must self-right within 15 seconds if capsized); positive stability checks up to 180 degrees
  • Area: Compressed air supply systems and breathing apparatus; verification of minimum 10+ minutes occupancy air capacity
    Check: Compressed air supply systems and breathing apparatus; verification of minimum 10+ minutes occupancy air capacity
  • Area: External sprinkler/water spray systems and thermal insulation condition; fire-resistant material integrity
    Check: External sprinkler/water spray systems and thermal insulation condition; fire-resistant material integrity
  • Area: Safety equipment verification: life jackets, personal protective equipment, harnesses, shock-absorbing seats, ladder condition
    Check: Safety equipment verification: life jackets, personal protective equipment, harnesses, shock-absorbing seats, ladder condition

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

Norsafe Mathilda 7.4 MKI
Mathilda 7.4 MKI ✓ verified
Application
Davit-launched totally enclosed lifeboat (TELB) for commercial shipping
Common Failures & Inspection Points
  • Area: Visual inspection of hull, superstructure and buoyant tanks for cracks, corrosion, deformation, or fire damage; condition of fire-retardant GRP material
    Check: Visual inspection of hull, superstructure and buoyant tanks for cracks, corrosion, deformation, or fire damage; condition of fire-retardant GRP material
  • Area: Engine propulsion system functionality test (minimum 3-minute run); fuel system integrity and emergency engine start capability
    Check: Engine propulsion system functionality test (minimum 3-minute run); fuel system integrity and emergency engine start capability
  • Area: Airtight seals and hatch integrity; condition and operation of all doors, hatches, and ventilation systems per MSC.535(107)/MSC.559(108)
    Check: Airtight seals and hatch integrity; condition and operation of all doors, hatches, and ventilation systems per MSC.535(107)/MSC.559(108)
  • Area: On-load and off-load release gear functionality; annual dynamic load testing at 1.1x maximum loaded weight; certification of hook release mechanisms
    Check: On-load and off-load release gear functionality; annual dynamic load testing at 1.1x maximum loaded weight; certification of hook release mechanisms
  • Area: Self-righting mechanism operation verification (must self-right within 15 seconds if capsized); positive stability checks up to 180 degrees
    Check: Self-righting mechanism operation verification (must self-right within 15 seconds if capsized); positive stability checks up to 180 degrees
  • Area: Compressed air supply systems and breathing apparatus; verification of minimum 10+ minutes occupancy air capacity
    Check: Compressed air supply systems and breathing apparatus; verification of minimum 10+ minutes occupancy air capacity
  • Area: External sprinkler/water spray systems and thermal insulation condition; fire-resistant material integrity
    Check: External sprinkler/water spray systems and thermal insulation condition; fire-resistant material integrity
  • Area: Safety equipment verification: life jackets, personal protective equipment, harnesses, shock-absorbing seats, ladder condition
    Check: Safety equipment verification: life jackets, personal protective equipment, harnesses, shock-absorbing seats, ladder condition

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

Norsafe Maxima-120 MKI
Maxima-120 MKI ✓ verified
Application
Davit-launched totally enclosed lifeboat (TELB) for large ships and offshore vessels/installations
Common Failures & Inspection Points
  • Area: Visual inspection of hull, superstructure and buoyant tanks for cracks, corrosion, deformation, or fire damage; condition of fire-retardant GRP material
    Check: Visual inspection of hull, superstructure and buoyant tanks for cracks, corrosion, deformation, or fire damage; condition of fire-retardant GRP material
  • Area: Engine propulsion system functionality test (minimum 3-minute run); fuel system integrity and emergency engine start capability
    Check: Engine propulsion system functionality test (minimum 3-minute run); fuel system integrity and emergency engine start capability
  • Area: Airtight seals and hatch integrity; condition and operation of all doors, hatches, and ventilation systems per MSC.535(107)/MSC.559(108)
    Check: Airtight seals and hatch integrity; condition and operation of all doors, hatches, and ventilation systems per MSC.535(107)/MSC.559(108)
  • Area: On-load and off-load release gear functionality; annual dynamic load testing at 1.1x maximum loaded weight; certification of hook release mechanisms
    Check: On-load and off-load release gear functionality; annual dynamic load testing at 1.1x maximum loaded weight; certification of hook release mechanisms
  • Area: Self-righting mechanism operation verification (must self-right within 15 seconds if capsized); positive stability checks up to 180 degrees
    Check: Self-righting mechanism operation verification (must self-right within 15 seconds if capsized); positive stability checks up to 180 degrees
  • Area: Compressed air supply systems and breathing apparatus; verification of minimum 10+ minutes occupancy air capacity
    Check: Compressed air supply systems and breathing apparatus; verification of minimum 10+ minutes occupancy air capacity
  • Area: External sprinkler/water spray systems and thermal insulation condition; fire-resistant material integrity
    Check: External sprinkler/water spray systems and thermal insulation condition; fire-resistant material integrity
  • Area: Safety equipment verification: life jackets, personal protective equipment, harnesses, shock-absorbing seats, ladder condition
    Check: Safety equipment verification: life jackets, personal protective equipment, harnesses, shock-absorbing seats, ladder condition

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

VIKING Life-Saving

9 ✓ 9 verified
VIKING Life-Saving Equipment VNJY-55 T
VNJY-55 T ✓ verified
Application
Totally Enclosed Lifeboat (TELB) for maritime/crew transport
Common Failures & Inspection Points
  • Area: Weekly visual inspection of TELB condition, hooks, and attachment points per SOLAS III/20
    Check: Weekly visual inspection of TELB condition, hooks, and attachment points per SOLAS III/20
  • Area: Monthly engine run-test for minimum 3 minutes to verify propulsion system functionality
    Check: Monthly engine run-test for minimum 3 minutes to verify propulsion system functionality
  • Area: Monthly davit structural inspection including wires, sheaves, and brake mechanisms
    Check: Monthly davit structural inspection including wires, sheaves, and brake mechanisms
  • Area: Annual certified service agent inspection of lifeboat hull structure, buoyancy foam, and watertight integrity
    Check: Annual certified service agent inspection of lifeboat hull structure, buoyancy foam, and watertight integrity
  • Area: Annual testing and adjustment of On-Load Release Hooks with hydrostatic interlock verification
    Check: Annual testing and adjustment of On-Load Release Hooks with hydrostatic interlock verification
  • Area: Annual inspection of windows, hatches, doors, and all hull penetrations for watertightness
    Check: Annual inspection of windows, hatches, doors, and all hull penetrations for watertightness
  • Area: Five-yearly comprehensive service including complete disassembly and overhaul of release units
    Check: Five-yearly comprehensive service including complete disassembly and overhaul of release units
  • Area: Verification of self-righting capability and polyurethane foam buoyancy integrity per LSA Code
    Check: Verification of self-righting capability and polyurethane foam buoyancy integrity per LSA Code

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

VIKING Life-Saving Equipment VNJY-68 DC
VNJY-68 DC ✓ verified
Application
Totally Enclosed Lifeboat (TELB) for maritime/dry cargo transport
Common Failures & Inspection Points
  • Area: Weekly visual inspection of TELB condition, hooks, and attachment points per SOLAS III/20
    Check: Weekly visual inspection of TELB condition, hooks, and attachment points per SOLAS III/20
  • Area: Monthly engine run-test for minimum 3 minutes to verify propulsion system functionality
    Check: Monthly engine run-test for minimum 3 minutes to verify propulsion system functionality
  • Area: Monthly davit structural inspection including wires, sheaves, and brake mechanisms
    Check: Monthly davit structural inspection including wires, sheaves, and brake mechanisms
  • Area: Annual certified service agent inspection of lifeboat hull structure, buoyancy foam, and watertight integrity
    Check: Annual certified service agent inspection of lifeboat hull structure, buoyancy foam, and watertight integrity
  • Area: Annual testing and adjustment of On-Load Release Hooks with hydrostatic interlock verification
    Check: Annual testing and adjustment of On-Load Release Hooks with hydrostatic interlock verification
  • Area: Annual inspection of windows, hatches, doors, and all hull penetrations for watertightness
    Check: Annual inspection of windows, hatches, doors, and all hull penetrations for watertightness
  • Area: Five-yearly comprehensive service including complete disassembly and overhaul of release units
    Check: Five-yearly comprehensive service including complete disassembly and overhaul of release units
  • Area: Verification of self-righting capability and polyurethane foam buoyancy integrity per LSA Code
    Check: Verification of self-righting capability and polyurethane foam buoyancy integrity per LSA Code

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

VIKING Life-Saving Equipment JYN-50 MKI
JYN-50 MKI ✓ verified
Application
Totally Enclosed Lifeboat (TELB) for maritime crew
Common Failures & Inspection Points
  • Area: Weekly visual inspection of TELB condition, hooks, and attachment points per SOLAS III/20
    Check: Weekly visual inspection of TELB condition, hooks, and attachment points per SOLAS III/20
  • Area: Monthly engine run-test for minimum 3 minutes to verify propulsion system functionality
    Check: Monthly engine run-test for minimum 3 minutes to verify propulsion system functionality
  • Area: Monthly davit structural inspection including wires, sheaves, and brake mechanisms
    Check: Monthly davit structural inspection including wires, sheaves, and brake mechanisms
  • Area: Annual certified service agent inspection of lifeboat hull structure, buoyancy foam, and watertight integrity
    Check: Annual certified service agent inspection of lifeboat hull structure, buoyancy foam, and watertight integrity
  • Area: Annual testing and adjustment of On-Load Release Hooks with hydrostatic interlock verification
    Check: Annual testing and adjustment of On-Load Release Hooks with hydrostatic interlock verification
  • Area: Annual inspection of windows, hatches, doors, and all hull penetrations for watertightness
    Check: Annual inspection of windows, hatches, doors, and all hull penetrations for watertightness
  • Area: Five-yearly comprehensive service including complete disassembly and overhaul of release units
    Check: Five-yearly comprehensive service including complete disassembly and overhaul of release units
  • Area: Verification of self-righting capability and polyurethane foam buoyancy integrity per LSA Code
    Check: Verification of self-righting capability and polyurethane foam buoyancy integrity per LSA Code

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

VIKING Life-Saving Equipment JYN-57 MKI T
JYN-57 MKI T ✓ verified
Application
Totally Enclosed Lifeboat (TELB) for maritime/tanker transport
Common Failures & Inspection Points
  • Area: Weekly visual inspection of TELB condition, hooks, and attachment points per SOLAS III/20
    Check: Weekly visual inspection of TELB condition, hooks, and attachment points per SOLAS III/20
  • Area: Monthly engine run-test for minimum 3 minutes to verify propulsion system functionality
    Check: Monthly engine run-test for minimum 3 minutes to verify propulsion system functionality
  • Area: Monthly davit structural inspection including wires, sheaves, and brake mechanisms
    Check: Monthly davit structural inspection including wires, sheaves, and brake mechanisms
  • Area: Annual certified service agent inspection of lifeboat hull structure, buoyancy foam, and watertight integrity
    Check: Annual certified service agent inspection of lifeboat hull structure, buoyancy foam, and watertight integrity
  • Area: Annual testing and adjustment of On-Load Release Hooks with hydrostatic interlock verification
    Check: Annual testing and adjustment of On-Load Release Hooks with hydrostatic interlock verification
  • Area: Annual inspection of windows, hatches, doors, and all hull penetrations for watertightness
    Check: Annual inspection of windows, hatches, doors, and all hull penetrations for watertightness
  • Area: Five-yearly comprehensive service including complete disassembly and overhaul of release units
    Check: Five-yearly comprehensive service including complete disassembly and overhaul of release units
  • Area: Verification of self-righting capability and polyurethane foam buoyancy integrity per LSA Code
    Check: Verification of self-righting capability and polyurethane foam buoyancy integrity per LSA Code

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

VIKING Life-Saving Equipment JYN-65 MKI
JYN-65 MKI ✓ verified
Application
Totally Enclosed Lifeboat (TELB) for maritime crew
Common Failures & Inspection Points
  • Area: Weekly visual inspection of TELB condition, hooks, and attachment points per SOLAS III/20
    Check: Weekly visual inspection of TELB condition, hooks, and attachment points per SOLAS III/20
  • Area: Monthly engine run-test for minimum 3 minutes to verify propulsion system functionality
    Check: Monthly engine run-test for minimum 3 minutes to verify propulsion system functionality
  • Area: Monthly davit structural inspection including wires, sheaves, and brake mechanisms
    Check: Monthly davit structural inspection including wires, sheaves, and brake mechanisms
  • Area: Annual certified service agent inspection of lifeboat hull structure, buoyancy foam, and watertight integrity
    Check: Annual certified service agent inspection of lifeboat hull structure, buoyancy foam, and watertight integrity
  • Area: Annual testing and adjustment of On-Load Release Hooks with hydrostatic interlock verification
    Check: Annual testing and adjustment of On-Load Release Hooks with hydrostatic interlock verification
  • Area: Annual inspection of windows, hatches, doors, and all hull penetrations for watertightness
    Check: Annual inspection of windows, hatches, doors, and all hull penetrations for watertightness
  • Area: Five-yearly comprehensive service including complete disassembly and overhaul of release units
    Check: Five-yearly comprehensive service including complete disassembly and overhaul of release units
  • Area: Verification of self-righting capability and polyurethane foam buoyancy integrity per LSA Code
    Check: Verification of self-righting capability and polyurethane foam buoyancy integrity per LSA Code

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

VIKING Life-Saving Equipment JYN-74 MKI DC
JYN-74 MKI DC ✓ verified
Application
Totally Enclosed Lifeboat (TELB) for maritime/dry cargo transport
Common Failures & Inspection Points
  • Area: Weekly visual inspection of TELB condition, hooks, and attachment points per SOLAS III/20
    Check: Weekly visual inspection of TELB condition, hooks, and attachment points per SOLAS III/20
  • Area: Monthly engine run-test for minimum 3 minutes to verify propulsion system functionality
    Check: Monthly engine run-test for minimum 3 minutes to verify propulsion system functionality
  • Area: Monthly davit structural inspection including wires, sheaves, and brake mechanisms
    Check: Monthly davit structural inspection including wires, sheaves, and brake mechanisms
  • Area: Annual certified service agent inspection of lifeboat hull structure, buoyancy foam, and watertight integrity
    Check: Annual certified service agent inspection of lifeboat hull structure, buoyancy foam, and watertight integrity
  • Area: Annual testing and adjustment of On-Load Release Hooks with hydrostatic interlock verification
    Check: Annual testing and adjustment of On-Load Release Hooks with hydrostatic interlock verification
  • Area: Annual inspection of windows, hatches, doors, and all hull penetrations for watertightness
    Check: Annual inspection of windows, hatches, doors, and all hull penetrations for watertightness
  • Area: Five-yearly comprehensive service including complete disassembly and overhaul of release units
    Check: Five-yearly comprehensive service including complete disassembly and overhaul of release units
  • Area: Verification of self-righting capability and polyurethane foam buoyancy integrity per LSA Code
    Check: Verification of self-righting capability and polyurethane foam buoyancy integrity per LSA Code

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

VIKING Life-Saving Equipment JYN-100 MKI T
JYN-100 MKI T ✓ verified
Application
Totally Enclosed Lifeboat (TELB) for maritime/tanker transport
Common Failures & Inspection Points
  • Area: Weekly visual inspection of TELB condition, hooks, and attachment points per SOLAS III/20
    Check: Weekly visual inspection of TELB condition, hooks, and attachment points per SOLAS III/20
  • Area: Monthly engine run-test for minimum 3 minutes to verify propulsion system functionality
    Check: Monthly engine run-test for minimum 3 minutes to verify propulsion system functionality
  • Area: Monthly davit structural inspection including wires, sheaves, and brake mechanisms
    Check: Monthly davit structural inspection including wires, sheaves, and brake mechanisms
  • Area: Annual certified service agent inspection of lifeboat hull structure, buoyancy foam, and watertight integrity
    Check: Annual certified service agent inspection of lifeboat hull structure, buoyancy foam, and watertight integrity
  • Area: Annual testing and adjustment of On-Load Release Hooks with hydrostatic interlock verification
    Check: Annual testing and adjustment of On-Load Release Hooks with hydrostatic interlock verification
  • Area: Annual inspection of windows, hatches, doors, and all hull penetrations for watertightness
    Check: Annual inspection of windows, hatches, doors, and all hull penetrations for watertightness
  • Area: Five-yearly comprehensive service including complete disassembly and overhaul of release units
    Check: Five-yearly comprehensive service including complete disassembly and overhaul of release units
  • Area: Verification of self-righting capability and polyurethane foam buoyancy integrity per LSA Code
    Check: Verification of self-righting capability and polyurethane foam buoyancy integrity per LSA Code

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

VIKING Life-Saving Equipment Miriam-8.5 TELB
Miriam-8.5 TELB ✓ verified
Application
Totally Enclosed Lifeboat (TELB) for maritime crew evacuation
Common Failures & Inspection Points
  • Area: Weekly visual inspection of TELB condition, hooks, and attachment points per SOLAS III/20
    Check: Weekly visual inspection of TELB condition, hooks, and attachment points per SOLAS III/20
  • Area: Monthly engine run-test for minimum 3 minutes to verify propulsion system functionality
    Check: Monthly engine run-test for minimum 3 minutes to verify propulsion system functionality
  • Area: Monthly davit structural inspection including wires, sheaves, and brake mechanisms
    Check: Monthly davit structural inspection including wires, sheaves, and brake mechanisms
  • Area: Annual certified service agent inspection of lifeboat hull structure, buoyancy foam, and watertight integrity
    Check: Annual certified service agent inspection of lifeboat hull structure, buoyancy foam, and watertight integrity
  • Area: Annual testing and adjustment of On-Load Release Hooks with hydrostatic interlock verification
    Check: Annual testing and adjustment of On-Load Release Hooks with hydrostatic interlock verification
  • Area: Annual inspection of windows, hatches, doors, and all hull penetrations for watertightness
    Check: Annual inspection of windows, hatches, doors, and all hull penetrations for watertightness
  • Area: Five-yearly comprehensive service including complete disassembly and overhaul of release units
    Check: Five-yearly comprehensive service including complete disassembly and overhaul of release units
  • Area: Verification of self-righting capability and polyurethane foam buoyancy integrity per LSA Code
    Check: Verification of self-righting capability and polyurethane foam buoyancy integrity per LSA Code

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

VIKING Life-Saving Equipment Maxima-120 MKI T
Maxima-120 MKI T ✓ verified
Application
Totally Enclosed Lifeboat (TELB) for maritime large-capacity evacuation
Common Failures & Inspection Points
  • Area: Weekly visual inspection of TELB condition, hooks, and attachment points per SOLAS III/20
    Check: Weekly visual inspection of TELB condition, hooks, and attachment points per SOLAS III/20
  • Area: Monthly engine run-test for minimum 3 minutes to verify propulsion system functionality
    Check: Monthly engine run-test for minimum 3 minutes to verify propulsion system functionality
  • Area: Monthly davit structural inspection including wires, sheaves, and brake mechanisms
    Check: Monthly davit structural inspection including wires, sheaves, and brake mechanisms
  • Area: Annual certified service agent inspection of lifeboat hull structure, buoyancy foam, and watertight integrity
    Check: Annual certified service agent inspection of lifeboat hull structure, buoyancy foam, and watertight integrity
  • Area: Annual testing and adjustment of On-Load Release Hooks with hydrostatic interlock verification
    Check: Annual testing and adjustment of On-Load Release Hooks with hydrostatic interlock verification
  • Area: Annual inspection of windows, hatches, doors, and all hull penetrations for watertightness
    Check: Annual inspection of windows, hatches, doors, and all hull penetrations for watertightness
  • Area: Five-yearly comprehensive service including complete disassembly and overhaul of release units
    Check: Five-yearly comprehensive service including complete disassembly and overhaul of release units
  • Area: Verification of self-righting capability and polyurethane foam buoyancy integrity per LSA Code
    Check: Verification of self-righting capability and polyurethane foam buoyancy integrity per LSA Code

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

AGI GROUP

5 ✓ 5 verified
AGI GROUP AG50CA/FA
AG50CA/FA ✓ verified
Application
Totally Enclosed Lifeboat (TELB) with gravity davit system for ocean-going cargo and tanker vessels
Common Failures & Inspection Points
  • Area: Weekly visual inspection of hull structure, fixed and loose equipment, including condition of davit hooks and attachment points
    Check: Weekly visual inspection of hull structure, fixed and loose equipment, including condition of davit hooks and attachment points
  • Area: Weekly operational test: run inboard diesel engine for minimum 3 minutes under supervision and reset on-load release gear
    Check: Weekly operational test: run inboard diesel engine for minimum 3 minutes under supervision and reset on-load release gear
  • Area: Monthly turn-out inspection: verify lifeboat can be launched from stowed position and check all LSA equipment inventory
    Check: Monthly turn-out inspection: verify lifeboat can be launched from stowed position and check all LSA equipment inventory
  • Area: Annual thorough examination of boat structure (internal and external), propulsion system, air supply system, and sprinkler/fire system functionality
    Check: Annual thorough examination of boat structure (internal and external), propulsion system, air supply system, and sprinkler/fire system functionality
  • Area: Annual fire-resistance material verification: confirm fire-retardant GRP plastic and closure mechanisms withstand specifications
    Check: Annual fire-resistance material verification: confirm fire-retardant GRP plastic and closure mechanisms withstand specifications
  • Area: Annual ventilation system check: verify ventilation capacity >= 5 m³/hour per person and operational integrity for 24+ hours
    Check: Annual ventilation system check: verify ventilation capacity >= 5 m³/hour per person and operational integrity for 24+ hours
  • Area: Annual self-righting mechanism test: confirm automatic uprighting within 15 seconds from capsized position
    Check: Annual self-righting mechanism test: confirm automatic uprighting within 15 seconds from capsized position
  • Area: Five-yearly comprehensive overhaul, overload operational test, and recertification by manufacturer or authorized IACS-certified service provider
    Check: Five-yearly comprehensive overhaul, overload operational test, and recertification by manufacturer or authorized IACS-certified service provider

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

AGI GROUP AG70CA/FA
AG70CA/FA ✓ verified
Application
Totally Enclosed Lifeboat (TELB) with fire-protection option and gravity davit system for ocean-going cargo and tanker vessels
Common Failures & Inspection Points
  • Area: Weekly visual inspection of hull structure, fixed and loose equipment, including condition of davit hooks and attachment points
    Check: Weekly visual inspection of hull structure, fixed and loose equipment, including condition of davit hooks and attachment points
  • Area: Weekly operational test: run inboard diesel engine for minimum 3 minutes under supervision and reset on-load release gear
    Check: Weekly operational test: run inboard diesel engine for minimum 3 minutes under supervision and reset on-load release gear
  • Area: Monthly turn-out inspection: verify lifeboat can be launched from stowed position and check all LSA equipment inventory
    Check: Monthly turn-out inspection: verify lifeboat can be launched from stowed position and check all LSA equipment inventory
  • Area: Annual thorough examination of boat structure (internal and external), propulsion system, air supply system, and sprinkler/fire system functionality
    Check: Annual thorough examination of boat structure (internal and external), propulsion system, air supply system, and sprinkler/fire system functionality
  • Area: Annual fire-resistance material verification: confirm fire-retardant GRP plastic and closure mechanisms withstand specifications
    Check: Annual fire-resistance material verification: confirm fire-retardant GRP plastic and closure mechanisms withstand specifications
  • Area: Annual ventilation system check: verify ventilation capacity >= 5 m³/hour per person and operational integrity for 24+ hours
    Check: Annual ventilation system check: verify ventilation capacity >= 5 m³/hour per person and operational integrity for 24+ hours
  • Area: Annual self-righting mechanism test: confirm automatic uprighting within 15 seconds from capsized position
    Check: Annual self-righting mechanism test: confirm automatic uprighting within 15 seconds from capsized position
  • Area: Five-yearly comprehensive overhaul, overload operational test, and recertification by manufacturer or authorized IACS-certified service provider
    Check: Five-yearly comprehensive overhaul, overload operational test, and recertification by manufacturer or authorized IACS-certified service provider

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

AGI GROUP AG75C/F
AG75C/F ✓ verified
Application
Totally Enclosed Lifeboat (TELB) with gravity davit system for ocean-going cargo and tanker vessels
Common Failures & Inspection Points
  • Area: Weekly visual inspection of hull structure, fixed and loose equipment, including condition of davit hooks and attachment points
    Check: Weekly visual inspection of hull structure, fixed and loose equipment, including condition of davit hooks and attachment points
  • Area: Weekly operational test: run inboard diesel engine for minimum 3 minutes under supervision and reset on-load release gear
    Check: Weekly operational test: run inboard diesel engine for minimum 3 minutes under supervision and reset on-load release gear
  • Area: Monthly turn-out inspection: verify lifeboat can be launched from stowed position and check all LSA equipment inventory
    Check: Monthly turn-out inspection: verify lifeboat can be launched from stowed position and check all LSA equipment inventory
  • Area: Annual thorough examination of boat structure (internal and external), propulsion system, air supply system, and sprinkler/fire system functionality
    Check: Annual thorough examination of boat structure (internal and external), propulsion system, air supply system, and sprinkler/fire system functionality
  • Area: Annual fire-resistance material verification: confirm fire-retardant GRP plastic and closure mechanisms withstand specifications
    Check: Annual fire-resistance material verification: confirm fire-retardant GRP plastic and closure mechanisms withstand specifications
  • Area: Annual ventilation system check: verify ventilation capacity >= 5 m³/hour per person and operational integrity for 24+ hours
    Check: Annual ventilation system check: verify ventilation capacity >= 5 m³/hour per person and operational integrity for 24+ hours
  • Area: Annual self-righting mechanism test: confirm automatic uprighting within 15 seconds from capsized position
    Check: Annual self-righting mechanism test: confirm automatic uprighting within 15 seconds from capsized position
  • Area: Five-yearly comprehensive overhaul, overload operational test, and recertification by manufacturer or authorized IACS-certified service provider
    Check: Five-yearly comprehensive overhaul, overload operational test, and recertification by manufacturer or authorized IACS-certified service provider

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

AGI GROUP AG80CA/FA
AG80CA/FA ✓ verified
Application
Totally Enclosed Lifeboat (TELB) with diesel engine and gravity davit system for ocean-going cargo and tanker vessels
Common Failures & Inspection Points
  • Area: Weekly visual inspection of hull structure, fixed and loose equipment, including condition of davit hooks and attachment points
    Check: Weekly visual inspection of hull structure, fixed and loose equipment, including condition of davit hooks and attachment points
  • Area: Weekly operational test: run inboard diesel engine for minimum 3 minutes under supervision and reset on-load release gear
    Check: Weekly operational test: run inboard diesel engine for minimum 3 minutes under supervision and reset on-load release gear
  • Area: Monthly turn-out inspection: verify lifeboat can be launched from stowed position and check all LSA equipment inventory
    Check: Monthly turn-out inspection: verify lifeboat can be launched from stowed position and check all LSA equipment inventory
  • Area: Annual thorough examination of boat structure (internal and external), propulsion system, air supply system, and sprinkler/fire system functionality
    Check: Annual thorough examination of boat structure (internal and external), propulsion system, air supply system, and sprinkler/fire system functionality
  • Area: Annual fire-resistance material verification: confirm fire-retardant GRP plastic and closure mechanisms withstand specifications
    Check: Annual fire-resistance material verification: confirm fire-retardant GRP plastic and closure mechanisms withstand specifications
  • Area: Annual ventilation system check: verify ventilation capacity >= 5 m³/hour per person and operational integrity for 24+ hours
    Check: Annual ventilation system check: verify ventilation capacity >= 5 m³/hour per person and operational integrity for 24+ hours
  • Area: Annual self-righting mechanism test: confirm automatic uprighting within 15 seconds from capsized position
    Check: Annual self-righting mechanism test: confirm automatic uprighting within 15 seconds from capsized position
  • Area: Five-yearly comprehensive overhaul, overload operational test, and recertification by manufacturer or authorized IACS-certified service provider
    Check: Five-yearly comprehensive overhaul, overload operational test, and recertification by manufacturer or authorized IACS-certified service provider

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

AGI GROUP AG117C/F
AG117C/F ✓ verified
Application
Totally Enclosed Lifeboat (TELB) with fire-protection option and gravity davit system for ocean-going cargo and tanker vessels; suitable for cruise ships
Common Failures & Inspection Points
  • Area: Weekly visual inspection of hull structure, fixed and loose equipment, including condition of davit hooks and attachment points
    Check: Weekly visual inspection of hull structure, fixed and loose equipment, including condition of davit hooks and attachment points
  • Area: Weekly operational test: run inboard diesel engine for minimum 3 minutes under supervision and reset on-load release gear
    Check: Weekly operational test: run inboard diesel engine for minimum 3 minutes under supervision and reset on-load release gear
  • Area: Monthly turn-out inspection: verify lifeboat can be launched from stowed position and check all LSA equipment inventory
    Check: Monthly turn-out inspection: verify lifeboat can be launched from stowed position and check all LSA equipment inventory
  • Area: Annual thorough examination of boat structure (internal and external), propulsion system, air supply system, and sprinkler/fire system functionality
    Check: Annual thorough examination of boat structure (internal and external), propulsion system, air supply system, and sprinkler/fire system functionality
  • Area: Annual fire-resistance material verification: confirm fire-retardant GRP plastic and closure mechanisms withstand specifications
    Check: Annual fire-resistance material verification: confirm fire-retardant GRP plastic and closure mechanisms withstand specifications
  • Area: Annual ventilation system check: verify ventilation capacity >= 5 m³/hour per person and operational integrity for 24+ hours
    Check: Annual ventilation system check: verify ventilation capacity >= 5 m³/hour per person and operational integrity for 24+ hours
  • Area: Annual self-righting mechanism test: confirm automatic uprighting within 15 seconds from capsized position
    Check: Annual self-righting mechanism test: confirm automatic uprighting within 15 seconds from capsized position
  • Area: Five-yearly comprehensive overhaul, overload operational test, and recertification by manufacturer or authorized IACS-certified service provider
    Check: Five-yearly comprehensive overhaul, overload operational test, and recertification by manufacturer or authorized IACS-certified service provider

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

Zhongyuan Ship Machinery Manufacture

2 ✓ 2 verified
Zhongyuan Ship Machinery Manufacture 150PAX Totally Enclosed Lifeboat Tanker Version
150PAX Totally Enclosed Lifeboat Tanker Version ✓ verified
Application
Ship life-saving equipment / Tanker vessel emergency evacuation
Common Failures & Inspection Points
  • Area: Hull structural integrity and GRP composite condition including cracks, delamination, and moisture ingress
    Check: Hull structural integrity and GRP composite condition including cracks, delamination, and moisture ingress
  • Area: Watertight door and hatch seals, frames, and operating mechanisms
    Check: Watertight door and hatch seals, frames, and operating mechanisms
  • Area: Davit hook systems, shackles, and hydrostatic release units (HRU) functionality
    Check: Davit hook systems, shackles, and hydrostatic release units (HRU) functionality
  • Area: Engine condition, fuel systems, and emergency start capability (diesel engine for motorized models)
    Check: Engine condition, fuel systems, and emergency start capability (diesel engine for motorized models)
  • Area: Buoyancy tank integrity and polyurethane foam saturation levels
    Check: Buoyancy tank integrity and polyurethane foam saturation levels
  • Area: Communication and signaling equipment (including radio, flares, mirrors)
    Check: Communication and signaling equipment (including radio, flares, mirrors)
  • Area: Life-saving appliances inventory (life jackets, survival kits, emergency food/water)
    Check: Life-saving appliances inventory (life jackets, survival kits, emergency food/water)
  • Area: Fire-protection systems and fire detection equipment (for tanker versions with spraying systems)
    Check: Fire-protection systems and fire detection equipment (for tanker versions with spraying systems)
  • Area: Electrical systems and backup power supplies
    Check: Electrical systems and backup power supplies
  • Area: Deck fittings, grab rails, and structural attachment points
    Check: Deck fittings, grab rails, and structural attachment points

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

Zhongyuan Ship Machinery Manufacture JY-QFP-6.0A Totally Enclosed Lifeboat (Normal Type)
JY-QFP-6.0A Totally Enclosed Lifeboat (Normal Type) ✓ verified
Application
Ship life-saving equipment / General cargo vessel emergency evacuation
Common Failures & Inspection Points
  • Area: Hull structural integrity and GRP composite condition including cracks, delamination, and moisture ingress
    Check: Hull structural integrity and GRP composite condition including cracks, delamination, and moisture ingress
  • Area: Watertight door and hatch seals, frames, and operating mechanisms
    Check: Watertight door and hatch seals, frames, and operating mechanisms
  • Area: Davit hook systems, shackles, and hydrostatic release units (HRU) functionality
    Check: Davit hook systems, shackles, and hydrostatic release units (HRU) functionality
  • Area: Engine condition, fuel systems, and emergency start capability (diesel engine for motorized models)
    Check: Engine condition, fuel systems, and emergency start capability (diesel engine for motorized models)
  • Area: Buoyancy tank integrity and polyurethane foam saturation levels
    Check: Buoyancy tank integrity and polyurethane foam saturation levels
  • Area: Communication and signaling equipment (including radio, flares, mirrors)
    Check: Communication and signaling equipment (including radio, flares, mirrors)
  • Area: Life-saving appliances inventory (life jackets, survival kits, emergency food/water)
    Check: Life-saving appliances inventory (life jackets, survival kits, emergency food/water)
  • Area: Fire-protection systems and fire detection equipment (for tanker versions with spraying systems)
    Check: Fire-protection systems and fire detection equipment (for tanker versions with spraying systems)
  • Area: Electrical systems and backup power supplies
    Check: Electrical systems and backup power supplies
  • Area: Deck fittings, grab rails, and structural attachment points
    Check: Deck fittings, grab rails, and structural attachment points

Typ-universelle Inspektionspunkte fuer Lifeboats (verifiziert, 2026-06).

Norsafe / Survitec

48
Norsafe / Survitec Norsafe JYN-6P
Norsafe JYN-6P unverified
Capacity (persons)
6
SOLAS Approved
ja
Norsafe / Survitec Norsafe JYN-10P
Norsafe JYN-10P unverified
Capacity (persons)
10
SOLAS Approved
ja
Norsafe / Survitec Norsafe JYN-16P
Norsafe JYN-16P unverified
Capacity (persons)
16
SOLAS Approved
ja
Norsafe / Survitec Norsafe JYN-20P
Norsafe JYN-20P unverified
Capacity (persons)
20
SOLAS Approved
ja
Norsafe / Survitec Norsafe JYN-25P
Norsafe JYN-25P unverified
Capacity (persons)
25
SOLAS Approved
ja
Norsafe / Survitec Norsafe JYN-35P
Norsafe JYN-35P unverified
Capacity (persons)
35
SOLAS Approved
ja
Norsafe / Survitec Norsafe JYN-50P
Norsafe JYN-50P unverified
Capacity (persons)
50
SOLAS Approved
ja
Norsafe / Survitec Norsafe JYN-65P
Norsafe JYN-65P unverified
Capacity (persons)
65
SOLAS Approved
ja
Norsafe / Survitec Norsafe JYN-80P
Norsafe JYN-80P unverified
Capacity (persons)
80
SOLAS Approved
ja
Norsafe / Survitec Norsafe JYN-100P
Norsafe JYN-100P unverified
Capacity (persons)
100
SOLAS Approved
ja
Norsafe / Survitec Norsafe JYN-120P
Norsafe JYN-120P unverified
Capacity (persons)
120
SOLAS Approved
ja
Norsafe / Survitec Norsafe JYN-150P
Norsafe JYN-150P unverified
Capacity (persons)
150
SOLAS Approved
ja
Norsafe / Survitec Norsafe GES-6P
Norsafe GES-6P unverified
Capacity (persons)
6
SOLAS Approved
ja
Norsafe / Survitec Norsafe GES-10P
Norsafe GES-10P unverified
Capacity (persons)
10
SOLAS Approved
ja
Norsafe / Survitec Norsafe GES-16P
Norsafe GES-16P unverified
Capacity (persons)
16
SOLAS Approved
ja
Norsafe / Survitec Norsafe GES-20P
Norsafe GES-20P unverified
Capacity (persons)
20
SOLAS Approved
ja
Norsafe / Survitec Norsafe GES-25P
Norsafe GES-25P unverified
Capacity (persons)
25
SOLAS Approved
ja
Norsafe / Survitec Norsafe GES-35P
Norsafe GES-35P unverified
Capacity (persons)
35
SOLAS Approved
ja
Norsafe / Survitec Norsafe GES-50P
Norsafe GES-50P unverified
Capacity (persons)
50
SOLAS Approved
ja
Norsafe / Survitec Norsafe GES-65P
Norsafe GES-65P unverified
Capacity (persons)
65
SOLAS Approved
ja
Norsafe / Survitec Norsafe GES-80P
Norsafe GES-80P unverified
Capacity (persons)
80
SOLAS Approved
ja
Norsafe / Survitec Norsafe GES-100P
Norsafe GES-100P unverified
Capacity (persons)
100
SOLAS Approved
ja
Norsafe / Survitec Norsafe GES-120P
Norsafe GES-120P unverified
Capacity (persons)
120
SOLAS Approved
ja
Norsafe / Survitec Norsafe GES-150P
Norsafe GES-150P unverified
Capacity (persons)
150
SOLAS Approved
ja
Norsafe / Survitec Norsafe Totally Enclosed Lifeboat 6P Diesel Inboard-C
Norsafe Totally Enclosed Lifeboat 6P Diesel Inboard-C unverified
Capacity (persons)
6
Engine
Diesel Inboard
SOLAS Approved
ja
Norsafe / Survitec Norsafe Totally Enclosed Lifeboat 10P Diesel Inboard-C
Norsafe Totally Enclosed Lifeboat 10P Diesel Inboard-C unverified
Capacity (persons)
10
Engine
Diesel Inboard
SOLAS Approved
ja
Norsafe / Survitec Norsafe Totally Enclosed Lifeboat 16P Diesel Inboard-C
Norsafe Totally Enclosed Lifeboat 16P Diesel Inboard-C unverified
Capacity (persons)
16
Engine
Diesel Inboard
SOLAS Approved
ja
Norsafe / Survitec Norsafe Totally Enclosed Lifeboat 20P Diesel Inboard-C
Norsafe Totally Enclosed Lifeboat 20P Diesel Inboard-C unverified
Capacity (persons)
20
Engine
Diesel Inboard
SOLAS Approved
ja
Norsafe / Survitec Norsafe Totally Enclosed Lifeboat 25P Diesel Inboard-C
Norsafe Totally Enclosed Lifeboat 25P Diesel Inboard-C unverified
Capacity (persons)
25
Engine
Diesel Inboard
SOLAS Approved
ja
Norsafe / Survitec Norsafe Totally Enclosed Lifeboat 35P Diesel Inboard-C
Norsafe Totally Enclosed Lifeboat 35P Diesel Inboard-C unverified
Capacity (persons)
35
Engine
Diesel Inboard
SOLAS Approved
ja
Norsafe / Survitec Norsafe Totally Enclosed Lifeboat 50P Diesel Inboard-C
Norsafe Totally Enclosed Lifeboat 50P Diesel Inboard-C unverified
Capacity (persons)
50
Engine
Diesel Inboard
SOLAS Approved
ja
Norsafe / Survitec Norsafe Totally Enclosed Lifeboat 65P Diesel Inboard-C
Norsafe Totally Enclosed Lifeboat 65P Diesel Inboard-C unverified
Capacity (persons)
65
Engine
Diesel Inboard
SOLAS Approved
ja
Norsafe / Survitec Norsafe Totally Enclosed Lifeboat 80P Diesel Inboard-C
Norsafe Totally Enclosed Lifeboat 80P Diesel Inboard-C unverified
Capacity (persons)
80
Engine
Diesel Inboard
SOLAS Approved
ja
Norsafe / Survitec Norsafe Totally Enclosed Lifeboat 100P Diesel Inboard-C
Norsafe Totally Enclosed Lifeboat 100P Diesel Inboard-C unverified
Capacity (persons)
100
Engine
Diesel Inboard
SOLAS Approved
ja
Norsafe / Survitec Norsafe Totally Enclosed Lifeboat 120P Diesel Inboard-C
Norsafe Totally Enclosed Lifeboat 120P Diesel Inboard-C unverified
Capacity (persons)
120
Engine
Diesel Inboard
SOLAS Approved
ja
Norsafe / Survitec Norsafe Totally Enclosed Lifeboat 150P Diesel Inboard-C
Norsafe Totally Enclosed Lifeboat 150P Diesel Inboard-C unverified
Capacity (persons)
150
Engine
Diesel Inboard
SOLAS Approved
ja
Norsafe / Survitec Norsafe Totally Enclosed Lifeboat 6P Diesel Outboard-C
Norsafe Totally Enclosed Lifeboat 6P Diesel Outboard-C unverified
Capacity (persons)
6
Engine
Diesel Outboard
SOLAS Approved
ja
Norsafe / Survitec Norsafe Totally Enclosed Lifeboat 10P Diesel Outboard-C
Norsafe Totally Enclosed Lifeboat 10P Diesel Outboard-C unverified
Capacity (persons)
10
Engine
Diesel Outboard
SOLAS Approved
ja
Norsafe / Survitec Norsafe Totally Enclosed Lifeboat 16P Diesel Outboard-C
Norsafe Totally Enclosed Lifeboat 16P Diesel Outboard-C unverified
Capacity (persons)
16
Engine
Diesel Outboard
SOLAS Approved
ja
Norsafe / Survitec Norsafe Totally Enclosed Lifeboat 20P Diesel Outboard-C
Norsafe Totally Enclosed Lifeboat 20P Diesel Outboard-C unverified
Capacity (persons)
20
Engine
Diesel Outboard
SOLAS Approved
ja
Norsafe / Survitec Norsafe Totally Enclosed Lifeboat 25P Diesel Outboard-C
Norsafe Totally Enclosed Lifeboat 25P Diesel Outboard-C unverified
Capacity (persons)
25
Engine
Diesel Outboard
SOLAS Approved
ja
Norsafe / Survitec Norsafe Totally Enclosed Lifeboat 35P Diesel Outboard-C
Norsafe Totally Enclosed Lifeboat 35P Diesel Outboard-C unverified
Capacity (persons)
35
Engine
Diesel Outboard
SOLAS Approved
ja
Norsafe / Survitec Norsafe Totally Enclosed Lifeboat 50P Diesel Outboard-C
Norsafe Totally Enclosed Lifeboat 50P Diesel Outboard-C unverified
Capacity (persons)
50
Engine
Diesel Outboard
SOLAS Approved
ja
Norsafe / Survitec Norsafe Totally Enclosed Lifeboat 65P Diesel Outboard-C
Norsafe Totally Enclosed Lifeboat 65P Diesel Outboard-C unverified
Capacity (persons)
65
Engine
Diesel Outboard
SOLAS Approved
ja
Norsafe / Survitec Norsafe Totally Enclosed Lifeboat 80P Diesel Outboard-C
Norsafe Totally Enclosed Lifeboat 80P Diesel Outboard-C unverified
Capacity (persons)
80
Engine
Diesel Outboard
SOLAS Approved
ja
Norsafe / Survitec Norsafe Totally Enclosed Lifeboat 100P Diesel Outboard-C
Norsafe Totally Enclosed Lifeboat 100P Diesel Outboard-C unverified
Capacity (persons)
100
Engine
Diesel Outboard
SOLAS Approved
ja
Norsafe / Survitec Norsafe Totally Enclosed Lifeboat 120P Diesel Outboard-C
Norsafe Totally Enclosed Lifeboat 120P Diesel Outboard-C unverified
Capacity (persons)
120
Engine
Diesel Outboard
SOLAS Approved
ja
Norsafe / Survitec Norsafe Totally Enclosed Lifeboat 150P Diesel Outboard-C
Norsafe Totally Enclosed Lifeboat 150P Diesel Outboard-C unverified
Capacity (persons)
150
Engine
Diesel Outboard
SOLAS Approved
ja

Schat-Harding / Survitec

48
Schat-Harding / Survitec Schat-Harding LBT-6P
Schat-Harding LBT-6P unverified
Capacity (persons)
6
SOLAS Approved
ja
Schat-Harding / Survitec Schat-Harding LBT-10P
Schat-Harding LBT-10P unverified
Capacity (persons)
10
SOLAS Approved
ja
Schat-Harding / Survitec Schat-Harding LBT-16P
Schat-Harding LBT-16P unverified
Capacity (persons)
16
SOLAS Approved
ja
Schat-Harding / Survitec Schat-Harding LBT-20P
Schat-Harding LBT-20P unverified
Capacity (persons)
20
SOLAS Approved
ja
Schat-Harding / Survitec Schat-Harding LBT-25P
Schat-Harding LBT-25P unverified
Capacity (persons)
25
SOLAS Approved
ja
Schat-Harding / Survitec Schat-Harding LBT-35P
Schat-Harding LBT-35P unverified
Capacity (persons)
35
SOLAS Approved
ja
Schat-Harding / Survitec Schat-Harding LBT-50P
Schat-Harding LBT-50P unverified
Capacity (persons)
50
SOLAS Approved
ja
Schat-Harding / Survitec Schat-Harding LBT-65P
Schat-Harding LBT-65P unverified
Capacity (persons)
65
SOLAS Approved
ja
Schat-Harding / Survitec Schat-Harding LBT-80P
Schat-Harding LBT-80P unverified
Capacity (persons)
80
SOLAS Approved
ja
Schat-Harding / Survitec Schat-Harding LBT-100P
Schat-Harding LBT-100P unverified
Capacity (persons)
100
SOLAS Approved
ja
Schat-Harding / Survitec Schat-Harding LBT-120P
Schat-Harding LBT-120P unverified
Capacity (persons)
120
SOLAS Approved
ja
Schat-Harding / Survitec Schat-Harding LBT-150P
Schat-Harding LBT-150P unverified
Capacity (persons)
150
SOLAS Approved
ja
Schat-Harding / Survitec Schat-Harding MES-6P
Schat-Harding MES-6P unverified
Capacity (persons)
6
SOLAS Approved
ja
Schat-Harding / Survitec Schat-Harding MES-10P
Schat-Harding MES-10P unverified
Capacity (persons)
10
SOLAS Approved
ja
Schat-Harding / Survitec Schat-Harding MES-16P
Schat-Harding MES-16P unverified
Capacity (persons)
16
SOLAS Approved
ja
Schat-Harding / Survitec Schat-Harding MES-20P
Schat-Harding MES-20P unverified
Capacity (persons)
20
SOLAS Approved
ja
Schat-Harding / Survitec Schat-Harding MES-25P
Schat-Harding MES-25P unverified
Capacity (persons)
25
SOLAS Approved
ja
Schat-Harding / Survitec Schat-Harding MES-35P
Schat-Harding MES-35P unverified
Capacity (persons)
35
SOLAS Approved
ja
Schat-Harding / Survitec Schat-Harding MES-50P
Schat-Harding MES-50P unverified
Capacity (persons)
50
SOLAS Approved
ja
Schat-Harding / Survitec Schat-Harding MES-65P
Schat-Harding MES-65P unverified
Capacity (persons)
65
SOLAS Approved
ja
Schat-Harding / Survitec Schat-Harding MES-80P
Schat-Harding MES-80P unverified
Capacity (persons)
80
SOLAS Approved
ja
Schat-Harding / Survitec Schat-Harding MES-100P
Schat-Harding MES-100P unverified
Capacity (persons)
100
SOLAS Approved
ja
Schat-Harding / Survitec Schat-Harding MES-120P
Schat-Harding MES-120P unverified
Capacity (persons)
120
SOLAS Approved
ja
Schat-Harding / Survitec Schat-Harding MES-150P
Schat-Harding MES-150P unverified
Capacity (persons)
150
SOLAS Approved
ja
Schat-Harding / Survitec Schat-Harding Totally Enclosed Lifeboat 6P Diesel Inboard-C
Schat-Harding Totally Enclosed Lifeboat 6P Diesel Inboard-C unverified
Capacity (persons)
6
Engine
Diesel Inboard
SOLAS Approved
ja
Schat-Harding / Survitec Schat-Harding Totally Enclosed Lifeboat 10P Diesel Inboard-C
Schat-Harding Totally Enclosed Lifeboat 10P Diesel Inboard-C unverified
Capacity (persons)
10
Engine
Diesel Inboard
SOLAS Approved
ja
Schat-Harding / Survitec Schat-Harding Totally Enclosed Lifeboat 16P Diesel Inboard-C
Schat-Harding Totally Enclosed Lifeboat 16P Diesel Inboard-C unverified
Capacity (persons)
16
Engine
Diesel Inboard
SOLAS Approved
ja
Schat-Harding / Survitec Schat-Harding Totally Enclosed Lifeboat 20P Diesel Inboard-C
Schat-Harding Totally Enclosed Lifeboat 20P Diesel Inboard-C unverified
Capacity (persons)
20
Engine
Diesel Inboard
SOLAS Approved
ja
Schat-Harding / Survitec Schat-Harding Totally Enclosed Lifeboat 25P Diesel Inboard-C
Schat-Harding Totally Enclosed Lifeboat 25P Diesel Inboard-C unverified
Capacity (persons)
25
Engine
Diesel Inboard
SOLAS Approved
ja
Schat-Harding / Survitec Schat-Harding Totally Enclosed Lifeboat 35P Diesel Inboard-C
Schat-Harding Totally Enclosed Lifeboat 35P Diesel Inboard-C unverified
Capacity (persons)
35
Engine
Diesel Inboard
SOLAS Approved
ja
Schat-Harding / Survitec Schat-Harding Totally Enclosed Lifeboat 50P Diesel Inboard-C
Schat-Harding Totally Enclosed Lifeboat 50P Diesel Inboard-C unverified
Capacity (persons)
50
Engine
Diesel Inboard
SOLAS Approved
ja
Schat-Harding / Survitec Schat-Harding Totally Enclosed Lifeboat 65P Diesel Inboard-C
Schat-Harding Totally Enclosed Lifeboat 65P Diesel Inboard-C unverified
Capacity (persons)
65
Engine
Diesel Inboard
SOLAS Approved
ja
Schat-Harding / Survitec Schat-Harding Totally Enclosed Lifeboat 80P Diesel Inboard-C
Schat-Harding Totally Enclosed Lifeboat 80P Diesel Inboard-C unverified
Capacity (persons)
80
Engine
Diesel Inboard
SOLAS Approved
ja
Schat-Harding / Survitec Schat-Harding Totally Enclosed Lifeboat 100P Diesel Inboard-C
Schat-Harding Totally Enclosed Lifeboat 100P Diesel Inboard-C unverified
Capacity (persons)
100
Engine
Diesel Inboard
SOLAS Approved
ja
Schat-Harding / Survitec Schat-Harding Totally Enclosed Lifeboat 120P Diesel Inboard-C
Schat-Harding Totally Enclosed Lifeboat 120P Diesel Inboard-C unverified
Capacity (persons)
120
Engine
Diesel Inboard
SOLAS Approved
ja
Schat-Harding / Survitec Schat-Harding Totally Enclosed Lifeboat 150P Diesel Inboard-C
Schat-Harding Totally Enclosed Lifeboat 150P Diesel Inboard-C unverified
Capacity (persons)
150
Engine
Diesel Inboard
SOLAS Approved
ja
Schat-Harding / Survitec Schat-Harding Totally Enclosed Lifeboat 6P Diesel Outboard-C
Schat-Harding Totally Enclosed Lifeboat 6P Diesel Outboard-C unverified
Capacity (persons)
6
Engine
Diesel Outboard
SOLAS Approved
ja
Schat-Harding / Survitec Schat-Harding Totally Enclosed Lifeboat 10P Diesel Outboard-C
Schat-Harding Totally Enclosed Lifeboat 10P Diesel Outboard-C unverified
Capacity (persons)
10
Engine
Diesel Outboard
SOLAS Approved
ja
Schat-Harding / Survitec Schat-Harding Totally Enclosed Lifeboat 16P Diesel Outboard-C
Schat-Harding Totally Enclosed Lifeboat 16P Diesel Outboard-C unverified
Capacity (persons)
16
Engine
Diesel Outboard
SOLAS Approved
ja
Schat-Harding / Survitec Schat-Harding Totally Enclosed Lifeboat 20P Diesel Outboard-C
Schat-Harding Totally Enclosed Lifeboat 20P Diesel Outboard-C unverified
Capacity (persons)
20
Engine
Diesel Outboard
SOLAS Approved
ja
Schat-Harding / Survitec Schat-Harding Totally Enclosed Lifeboat 25P Diesel Outboard-C
Schat-Harding Totally Enclosed Lifeboat 25P Diesel Outboard-C unverified
Capacity (persons)
25
Engine
Diesel Outboard
SOLAS Approved
ja
Schat-Harding / Survitec Schat-Harding Totally Enclosed Lifeboat 35P Diesel Outboard-C
Schat-Harding Totally Enclosed Lifeboat 35P Diesel Outboard-C unverified
Capacity (persons)
35
Engine
Diesel Outboard
SOLAS Approved
ja
Schat-Harding / Survitec Schat-Harding Totally Enclosed Lifeboat 50P Diesel Outboard-C
Schat-Harding Totally Enclosed Lifeboat 50P Diesel Outboard-C unverified
Capacity (persons)
50
Engine
Diesel Outboard
SOLAS Approved
ja
Schat-Harding / Survitec Schat-Harding Totally Enclosed Lifeboat 65P Diesel Outboard-C
Schat-Harding Totally Enclosed Lifeboat 65P Diesel Outboard-C unverified
Capacity (persons)
65
Engine
Diesel Outboard
SOLAS Approved
ja
Schat-Harding / Survitec Schat-Harding Totally Enclosed Lifeboat 80P Diesel Outboard-C
Schat-Harding Totally Enclosed Lifeboat 80P Diesel Outboard-C unverified
Capacity (persons)
80
Engine
Diesel Outboard
SOLAS Approved
ja
Schat-Harding / Survitec Schat-Harding Totally Enclosed Lifeboat 100P Diesel Outboard-C
Schat-Harding Totally Enclosed Lifeboat 100P Diesel Outboard-C unverified
Capacity (persons)
100
Engine
Diesel Outboard
SOLAS Approved
ja
Schat-Harding / Survitec Schat-Harding Totally Enclosed Lifeboat 120P Diesel Outboard-C
Schat-Harding Totally Enclosed Lifeboat 120P Diesel Outboard-C unverified
Capacity (persons)
120
Engine
Diesel Outboard
SOLAS Approved
ja
Schat-Harding / Survitec Schat-Harding Totally Enclosed Lifeboat 150P Diesel Outboard-C
Schat-Harding Totally Enclosed Lifeboat 150P Diesel Outboard-C unverified
Capacity (persons)
150
Engine
Diesel Outboard
SOLAS Approved
ja

Jiangyin Neptune

36
Jiangyin Neptune NPT TELB-6P
NPT TELB-6P unverified
Capacity (persons)
6
SOLAS Approved
ja
Jiangyin Neptune NPT TELB-10P
NPT TELB-10P unverified
Capacity (persons)
10
SOLAS Approved
ja
Jiangyin Neptune NPT TELB-16P
NPT TELB-16P unverified
Capacity (persons)
16
SOLAS Approved
ja
Jiangyin Neptune NPT TELB-20P
NPT TELB-20P unverified
Capacity (persons)
20
SOLAS Approved
ja
Jiangyin Neptune NPT TELB-25P
NPT TELB-25P unverified
Capacity (persons)
25
SOLAS Approved
ja
Jiangyin Neptune NPT TELB-35P
NPT TELB-35P unverified
Capacity (persons)
35
SOLAS Approved
ja
Jiangyin Neptune NPT TELB-50P
NPT TELB-50P unverified
Capacity (persons)
50
SOLAS Approved
ja
Jiangyin Neptune NPT TELB-65P
NPT TELB-65P unverified
Capacity (persons)
65
SOLAS Approved
ja
Jiangyin Neptune NPT TELB-80P
NPT TELB-80P unverified
Capacity (persons)
80
SOLAS Approved
ja
Jiangyin Neptune NPT TELB-100P
NPT TELB-100P unverified
Capacity (persons)
100
SOLAS Approved
ja
Jiangyin Neptune NPT TELB-120P
NPT TELB-120P unverified
Capacity (persons)
120
SOLAS Approved
ja
Jiangyin Neptune NPT TELB-150P
NPT TELB-150P unverified
Capacity (persons)
150
SOLAS Approved
ja
Jiangyin Neptune Jiangyin Neptune Totally Enclosed Lifeboat 6P Diesel Inboard-C
Jiangyin Neptune Totally Enclosed Lifeboat 6P Diesel Inboard-C unverified
Capacity (persons)
6
Engine
Diesel Inboard
SOLAS Approved
ja
Jiangyin Neptune Jiangyin Neptune Totally Enclosed Lifeboat 10P Diesel Inboard-C
Jiangyin Neptune Totally Enclosed Lifeboat 10P Diesel Inboard-C unverified
Capacity (persons)
10
Engine
Diesel Inboard
SOLAS Approved
ja
Jiangyin Neptune Jiangyin Neptune Totally Enclosed Lifeboat 16P Diesel Inboard-C
Jiangyin Neptune Totally Enclosed Lifeboat 16P Diesel Inboard-C unverified
Capacity (persons)
16
Engine
Diesel Inboard
SOLAS Approved
ja
Jiangyin Neptune Jiangyin Neptune Totally Enclosed Lifeboat 20P Diesel Inboard-C
Jiangyin Neptune Totally Enclosed Lifeboat 20P Diesel Inboard-C unverified
Capacity (persons)
20
Engine
Diesel Inboard
SOLAS Approved
ja
Jiangyin Neptune Jiangyin Neptune Totally Enclosed Lifeboat 25P Diesel Inboard-C
Jiangyin Neptune Totally Enclosed Lifeboat 25P Diesel Inboard-C unverified
Capacity (persons)
25
Engine
Diesel Inboard
SOLAS Approved
ja
Jiangyin Neptune Jiangyin Neptune Totally Enclosed Lifeboat 35P Diesel Inboard-C
Jiangyin Neptune Totally Enclosed Lifeboat 35P Diesel Inboard-C unverified
Capacity (persons)
35
Engine
Diesel Inboard
SOLAS Approved
ja
Jiangyin Neptune Jiangyin Neptune Totally Enclosed Lifeboat 50P Diesel Inboard-C
Jiangyin Neptune Totally Enclosed Lifeboat 50P Diesel Inboard-C unverified
Capacity (persons)
50
Engine
Diesel Inboard
SOLAS Approved
ja
Jiangyin Neptune Jiangyin Neptune Totally Enclosed Lifeboat 65P Diesel Inboard-C
Jiangyin Neptune Totally Enclosed Lifeboat 65P Diesel Inboard-C unverified
Capacity (persons)
65
Engine
Diesel Inboard
SOLAS Approved
ja
Jiangyin Neptune Jiangyin Neptune Totally Enclosed Lifeboat 80P Diesel Inboard-C
Jiangyin Neptune Totally Enclosed Lifeboat 80P Diesel Inboard-C unverified
Capacity (persons)
80
Engine
Diesel Inboard
SOLAS Approved
ja
Jiangyin Neptune Jiangyin Neptune Totally Enclosed Lifeboat 100P Diesel Inboard-C
Jiangyin Neptune Totally Enclosed Lifeboat 100P Diesel Inboard-C unverified
Capacity (persons)
100
Engine
Diesel Inboard
SOLAS Approved
ja
Jiangyin Neptune Jiangyin Neptune Totally Enclosed Lifeboat 120P Diesel Inboard-C
Jiangyin Neptune Totally Enclosed Lifeboat 120P Diesel Inboard-C unverified
Capacity (persons)
120
Engine
Diesel Inboard
SOLAS Approved
ja
Jiangyin Neptune Jiangyin Neptune Totally Enclosed Lifeboat 150P Diesel Inboard-C
Jiangyin Neptune Totally Enclosed Lifeboat 150P Diesel Inboard-C unverified
Capacity (persons)
150
Engine
Diesel Inboard
SOLAS Approved
ja
Jiangyin Neptune Jiangyin Neptune Totally Enclosed Lifeboat 6P Diesel Outboard-C
Jiangyin Neptune Totally Enclosed Lifeboat 6P Diesel Outboard-C unverified
Capacity (persons)
6
Engine
Diesel Outboard
SOLAS Approved
ja
Jiangyin Neptune Jiangyin Neptune Totally Enclosed Lifeboat 10P Diesel Outboard-C
Jiangyin Neptune Totally Enclosed Lifeboat 10P Diesel Outboard-C unverified
Capacity (persons)
10
Engine
Diesel Outboard
SOLAS Approved
ja
Jiangyin Neptune Jiangyin Neptune Totally Enclosed Lifeboat 16P Diesel Outboard-C
Jiangyin Neptune Totally Enclosed Lifeboat 16P Diesel Outboard-C unverified
Capacity (persons)
16
Engine
Diesel Outboard
SOLAS Approved
ja
Jiangyin Neptune Jiangyin Neptune Totally Enclosed Lifeboat 20P Diesel Outboard-C
Jiangyin Neptune Totally Enclosed Lifeboat 20P Diesel Outboard-C unverified
Capacity (persons)
20
Engine
Diesel Outboard
SOLAS Approved
ja
Jiangyin Neptune Jiangyin Neptune Totally Enclosed Lifeboat 25P Diesel Outboard-C
Jiangyin Neptune Totally Enclosed Lifeboat 25P Diesel Outboard-C unverified
Capacity (persons)
25
Engine
Diesel Outboard
SOLAS Approved
ja
Jiangyin Neptune Jiangyin Neptune Totally Enclosed Lifeboat 35P Diesel Outboard-C
Jiangyin Neptune Totally Enclosed Lifeboat 35P Diesel Outboard-C unverified
Capacity (persons)
35
Engine
Diesel Outboard
SOLAS Approved
ja
Jiangyin Neptune Jiangyin Neptune Totally Enclosed Lifeboat 50P Diesel Outboard-C
Jiangyin Neptune Totally Enclosed Lifeboat 50P Diesel Outboard-C unverified
Capacity (persons)
50
Engine
Diesel Outboard
SOLAS Approved
ja
Jiangyin Neptune Jiangyin Neptune Totally Enclosed Lifeboat 65P Diesel Outboard-C
Jiangyin Neptune Totally Enclosed Lifeboat 65P Diesel Outboard-C unverified
Capacity (persons)
65
Engine
Diesel Outboard
SOLAS Approved
ja
Jiangyin Neptune Jiangyin Neptune Totally Enclosed Lifeboat 80P Diesel Outboard-C
Jiangyin Neptune Totally Enclosed Lifeboat 80P Diesel Outboard-C unverified
Capacity (persons)
80
Engine
Diesel Outboard
SOLAS Approved
ja
Jiangyin Neptune Jiangyin Neptune Totally Enclosed Lifeboat 100P Diesel Outboard-C
Jiangyin Neptune Totally Enclosed Lifeboat 100P Diesel Outboard-C unverified
Capacity (persons)
100
Engine
Diesel Outboard
SOLAS Approved
ja
Jiangyin Neptune Jiangyin Neptune Totally Enclosed Lifeboat 120P Diesel Outboard-C
Jiangyin Neptune Totally Enclosed Lifeboat 120P Diesel Outboard-C unverified
Capacity (persons)
120
Engine
Diesel Outboard
SOLAS Approved
ja
Jiangyin Neptune Jiangyin Neptune Totally Enclosed Lifeboat 150P Diesel Outboard-C
Jiangyin Neptune Totally Enclosed Lifeboat 150P Diesel Outboard-C unverified
Capacity (persons)
150
Engine
Diesel Outboard
SOLAS Approved
ja

Fassmer

33
Fassmer Fassmer SEL-20P
Fassmer SEL-20P unverified
Capacity (persons)
20
SOLAS Approved
ja
Fassmer Fassmer SEL-25P
Fassmer SEL-25P unverified
Capacity (persons)
25
SOLAS Approved
ja
Fassmer Fassmer SEL-35P
Fassmer SEL-35P unverified
Capacity (persons)
35
SOLAS Approved
ja
Fassmer Fassmer SEL-50P
Fassmer SEL-50P unverified
Capacity (persons)
50
SOLAS Approved
ja
Fassmer Fassmer SEL-65P
Fassmer SEL-65P unverified
Capacity (persons)
65
SOLAS Approved
ja
Fassmer Fassmer SEL-80P
Fassmer SEL-80P unverified
Capacity (persons)
80
SOLAS Approved
ja
Fassmer Fassmer SEL-100P
Fassmer SEL-100P unverified
Capacity (persons)
100
SOLAS Approved
ja
Fassmer Fassmer SEL-120P
Fassmer SEL-120P unverified
Capacity (persons)
120
SOLAS Approved
ja
Fassmer Fassmer SEL-150P
Fassmer SEL-150P unverified
Capacity (persons)
150
SOLAS Approved
ja
Fassmer Fassmer Totally Enclosed Lifeboat 6P Diesel Inboard-C
Fassmer Totally Enclosed Lifeboat 6P Diesel Inboard-C unverified
Capacity (persons)
6
Engine
Diesel Inboard
SOLAS Approved
ja
Fassmer Fassmer Totally Enclosed Lifeboat 10P Diesel Inboard-C
Fassmer Totally Enclosed Lifeboat 10P Diesel Inboard-C unverified
Capacity (persons)
10
Engine
Diesel Inboard
SOLAS Approved
ja
Fassmer Fassmer Totally Enclosed Lifeboat 16P Diesel Inboard-C
Fassmer Totally Enclosed Lifeboat 16P Diesel Inboard-C unverified
Capacity (persons)
16
Engine
Diesel Inboard
SOLAS Approved
ja
Fassmer Fassmer Totally Enclosed Lifeboat 20P Diesel Inboard-C
Fassmer Totally Enclosed Lifeboat 20P Diesel Inboard-C unverified
Capacity (persons)
20
Engine
Diesel Inboard
SOLAS Approved
ja
Fassmer Fassmer Totally Enclosed Lifeboat 25P Diesel Inboard-C
Fassmer Totally Enclosed Lifeboat 25P Diesel Inboard-C unverified
Capacity (persons)
25
Engine
Diesel Inboard
SOLAS Approved
ja
Fassmer Fassmer Totally Enclosed Lifeboat 35P Diesel Inboard-C
Fassmer Totally Enclosed Lifeboat 35P Diesel Inboard-C unverified
Capacity (persons)
35
Engine
Diesel Inboard
SOLAS Approved
ja
Fassmer Fassmer Totally Enclosed Lifeboat 50P Diesel Inboard-C
Fassmer Totally Enclosed Lifeboat 50P Diesel Inboard-C unverified
Capacity (persons)
50
Engine
Diesel Inboard
SOLAS Approved
ja
Fassmer Fassmer Totally Enclosed Lifeboat 65P Diesel Inboard-C
Fassmer Totally Enclosed Lifeboat 65P Diesel Inboard-C unverified
Capacity (persons)
65
Engine
Diesel Inboard
SOLAS Approved
ja
Fassmer Fassmer Totally Enclosed Lifeboat 80P Diesel Inboard-C
Fassmer Totally Enclosed Lifeboat 80P Diesel Inboard-C unverified
Capacity (persons)
80
Engine
Diesel Inboard
SOLAS Approved
ja
Fassmer Fassmer Totally Enclosed Lifeboat 100P Diesel Inboard-C
Fassmer Totally Enclosed Lifeboat 100P Diesel Inboard-C unverified
Capacity (persons)
100
Engine
Diesel Inboard
SOLAS Approved
ja
Fassmer Fassmer Totally Enclosed Lifeboat 120P Diesel Inboard-C
Fassmer Totally Enclosed Lifeboat 120P Diesel Inboard-C unverified
Capacity (persons)
120
Engine
Diesel Inboard
SOLAS Approved
ja
Fassmer Fassmer Totally Enclosed Lifeboat 150P Diesel Inboard-C
Fassmer Totally Enclosed Lifeboat 150P Diesel Inboard-C unverified
Capacity (persons)
150
Engine
Diesel Inboard
SOLAS Approved
ja
Fassmer Fassmer Totally Enclosed Lifeboat 6P Diesel Outboard-C
Fassmer Totally Enclosed Lifeboat 6P Diesel Outboard-C unverified
Capacity (persons)
6
Engine
Diesel Outboard
SOLAS Approved
ja
Fassmer Fassmer Totally Enclosed Lifeboat 10P Diesel Outboard-C
Fassmer Totally Enclosed Lifeboat 10P Diesel Outboard-C unverified
Capacity (persons)
10
Engine
Diesel Outboard
SOLAS Approved
ja
Fassmer Fassmer Totally Enclosed Lifeboat 16P Diesel Outboard-C
Fassmer Totally Enclosed Lifeboat 16P Diesel Outboard-C unverified
Capacity (persons)
16
Engine
Diesel Outboard
SOLAS Approved
ja
Fassmer Fassmer Totally Enclosed Lifeboat 20P Diesel Outboard-C
Fassmer Totally Enclosed Lifeboat 20P Diesel Outboard-C unverified
Capacity (persons)
20
Engine
Diesel Outboard
SOLAS Approved
ja
Fassmer Fassmer Totally Enclosed Lifeboat 25P Diesel Outboard-C
Fassmer Totally Enclosed Lifeboat 25P Diesel Outboard-C unverified
Capacity (persons)
25
Engine
Diesel Outboard
SOLAS Approved
ja
Fassmer Fassmer Totally Enclosed Lifeboat 35P Diesel Outboard-C
Fassmer Totally Enclosed Lifeboat 35P Diesel Outboard-C unverified
Capacity (persons)
35
Engine
Diesel Outboard
SOLAS Approved
ja
Fassmer Fassmer Totally Enclosed Lifeboat 50P Diesel Outboard-C
Fassmer Totally Enclosed Lifeboat 50P Diesel Outboard-C unverified
Capacity (persons)
50
Engine
Diesel Outboard
SOLAS Approved
ja
Fassmer Fassmer Totally Enclosed Lifeboat 65P Diesel Outboard-C
Fassmer Totally Enclosed Lifeboat 65P Diesel Outboard-C unverified
Capacity (persons)
65
Engine
Diesel Outboard
SOLAS Approved
ja
Fassmer Fassmer Totally Enclosed Lifeboat 80P Diesel Outboard-C
Fassmer Totally Enclosed Lifeboat 80P Diesel Outboard-C unverified
Capacity (persons)
80
Engine
Diesel Outboard
SOLAS Approved
ja
Fassmer Fassmer Totally Enclosed Lifeboat 100P Diesel Outboard-C
Fassmer Totally Enclosed Lifeboat 100P Diesel Outboard-C unverified
Capacity (persons)
100
Engine
Diesel Outboard
SOLAS Approved
ja
Fassmer Fassmer Totally Enclosed Lifeboat 120P Diesel Outboard-C
Fassmer Totally Enclosed Lifeboat 120P Diesel Outboard-C unverified
Capacity (persons)
120
Engine
Diesel Outboard
SOLAS Approved
ja
Fassmer Fassmer Totally Enclosed Lifeboat 150P Diesel Outboard-C
Fassmer Totally Enclosed Lifeboat 150P Diesel Outboard-C unverified
Capacity (persons)
150
Engine
Diesel Outboard
SOLAS Approved
ja

Palfinger Marine Safety

32
Palfinger Marine Safety Palfinger TELB-25P
Palfinger TELB-25P unverified
Capacity (persons)
25
Palfinger Marine Safety Palfinger TELB-35P
Palfinger TELB-35P unverified
Capacity (persons)
35
Palfinger Marine Safety Palfinger TELB-50P
Palfinger TELB-50P unverified
Capacity (persons)
50
Palfinger Marine Safety Palfinger TELB-65P
Palfinger TELB-65P unverified
Capacity (persons)
65
Palfinger Marine Safety Palfinger TELB-80P
Palfinger TELB-80P unverified
Capacity (persons)
80
Palfinger Marine Safety Palfinger TELB-100P
Palfinger TELB-100P unverified
Capacity (persons)
100
Palfinger Marine Safety Palfinger TELB-120P
Palfinger TELB-120P unverified
Capacity (persons)
120
Palfinger Marine Safety Palfinger TELB-150P
Palfinger TELB-150P unverified
Capacity (persons)
150
Palfinger Marine Safety Palfinger Marine Safety Totally Enclosed Lifeboat 6P Diesel Inboard-C
Palfinger Marine Safety Totally Enclosed Lifeboat 6P Diesel Inboard-C unverified
Capacity (persons)
6
Engine
Diesel Inboard
SOLAS Approved
ja
Palfinger Marine Safety Palfinger Marine Safety Totally Enclosed Lifeboat 10P Diesel Inboard-C
Palfinger Marine Safety Totally Enclosed Lifeboat 10P Diesel Inboard-C unverified
Capacity (persons)
10
Engine
Diesel Inboard
SOLAS Approved
ja
Palfinger Marine Safety Palfinger Marine Safety Totally Enclosed Lifeboat 16P Diesel Inboard-C
Palfinger Marine Safety Totally Enclosed Lifeboat 16P Diesel Inboard-C unverified
Capacity (persons)
16
Engine
Diesel Inboard
SOLAS Approved
ja
Palfinger Marine Safety Palfinger Marine Safety Totally Enclosed Lifeboat 20P Diesel Inboard-C
Palfinger Marine Safety Totally Enclosed Lifeboat 20P Diesel Inboard-C unverified
Capacity (persons)
20
Engine
Diesel Inboard
SOLAS Approved
ja
Palfinger Marine Safety Palfinger Marine Safety Totally Enclosed Lifeboat 25P Diesel Inboard-C
Palfinger Marine Safety Totally Enclosed Lifeboat 25P Diesel Inboard-C unverified
Capacity (persons)
25
Engine
Diesel Inboard
SOLAS Approved
ja
Palfinger Marine Safety Palfinger Marine Safety Totally Enclosed Lifeboat 35P Diesel Inboard-C
Palfinger Marine Safety Totally Enclosed Lifeboat 35P Diesel Inboard-C unverified
Capacity (persons)
35
Engine
Diesel Inboard
SOLAS Approved
ja
Palfinger Marine Safety Palfinger Marine Safety Totally Enclosed Lifeboat 50P Diesel Inboard-C
Palfinger Marine Safety Totally Enclosed Lifeboat 50P Diesel Inboard-C unverified
Capacity (persons)
50
Engine
Diesel Inboard
SOLAS Approved
ja
Palfinger Marine Safety Palfinger Marine Safety Totally Enclosed Lifeboat 65P Diesel Inboard-C
Palfinger Marine Safety Totally Enclosed Lifeboat 65P Diesel Inboard-C unverified
Capacity (persons)
65
Engine
Diesel Inboard
SOLAS Approved
ja
Palfinger Marine Safety Palfinger Marine Safety Totally Enclosed Lifeboat 80P Diesel Inboard-C
Palfinger Marine Safety Totally Enclosed Lifeboat 80P Diesel Inboard-C unverified
Capacity (persons)
80
Engine
Diesel Inboard
SOLAS Approved
ja
Palfinger Marine Safety Palfinger Marine Safety Totally Enclosed Lifeboat 100P Diesel Inboard-C
Palfinger Marine Safety Totally Enclosed Lifeboat 100P Diesel Inboard-C unverified
Capacity (persons)
100
Engine
Diesel Inboard
SOLAS Approved
ja
Palfinger Marine Safety Palfinger Marine Safety Totally Enclosed Lifeboat 120P Diesel Inboard-C
Palfinger Marine Safety Totally Enclosed Lifeboat 120P Diesel Inboard-C unverified
Capacity (persons)
120
Engine
Diesel Inboard
SOLAS Approved
ja
Palfinger Marine Safety Palfinger Marine Safety Totally Enclosed Lifeboat 150P Diesel Inboard-C
Palfinger Marine Safety Totally Enclosed Lifeboat 150P Diesel Inboard-C unverified
Capacity (persons)
150
Engine
Diesel Inboard
SOLAS Approved
ja
Palfinger Marine Safety Palfinger Marine Safety Totally Enclosed Lifeboat 6P Diesel Outboard-C
Palfinger Marine Safety Totally Enclosed Lifeboat 6P Diesel Outboard-C unverified
Capacity (persons)
6
Engine
Diesel Outboard
SOLAS Approved
ja
Palfinger Marine Safety Palfinger Marine Safety Totally Enclosed Lifeboat 10P Diesel Outboard-C
Palfinger Marine Safety Totally Enclosed Lifeboat 10P Diesel Outboard-C unverified
Capacity (persons)
10
Engine
Diesel Outboard
SOLAS Approved
ja
Palfinger Marine Safety Palfinger Marine Safety Totally Enclosed Lifeboat 16P Diesel Outboard-C
Palfinger Marine Safety Totally Enclosed Lifeboat 16P Diesel Outboard-C unverified
Capacity (persons)
16
Engine
Diesel Outboard
SOLAS Approved
ja
Palfinger Marine Safety Palfinger Marine Safety Totally Enclosed Lifeboat 20P Diesel Outboard-C
Palfinger Marine Safety Totally Enclosed Lifeboat 20P Diesel Outboard-C unverified
Capacity (persons)
20
Engine
Diesel Outboard
SOLAS Approved
ja
Palfinger Marine Safety Palfinger Marine Safety Totally Enclosed Lifeboat 25P Diesel Outboard-C
Palfinger Marine Safety Totally Enclosed Lifeboat 25P Diesel Outboard-C unverified
Capacity (persons)
25
Engine
Diesel Outboard
SOLAS Approved
ja
Palfinger Marine Safety Palfinger Marine Safety Totally Enclosed Lifeboat 35P Diesel Outboard-C
Palfinger Marine Safety Totally Enclosed Lifeboat 35P Diesel Outboard-C unverified
Capacity (persons)
35
Engine
Diesel Outboard
SOLAS Approved
ja
Palfinger Marine Safety Palfinger Marine Safety Totally Enclosed Lifeboat 50P Diesel Outboard-C
Palfinger Marine Safety Totally Enclosed Lifeboat 50P Diesel Outboard-C unverified
Capacity (persons)
50
Engine
Diesel Outboard
SOLAS Approved
ja
Palfinger Marine Safety Palfinger Marine Safety Totally Enclosed Lifeboat 65P Diesel Outboard-C
Palfinger Marine Safety Totally Enclosed Lifeboat 65P Diesel Outboard-C unverified
Capacity (persons)
65
Engine
Diesel Outboard
SOLAS Approved
ja
Palfinger Marine Safety Palfinger Marine Safety Totally Enclosed Lifeboat 80P Diesel Outboard-C
Palfinger Marine Safety Totally Enclosed Lifeboat 80P Diesel Outboard-C unverified
Capacity (persons)
80
Engine
Diesel Outboard
SOLAS Approved
ja
Palfinger Marine Safety Palfinger Marine Safety Totally Enclosed Lifeboat 100P Diesel Outboard-C
Palfinger Marine Safety Totally Enclosed Lifeboat 100P Diesel Outboard-C unverified
Capacity (persons)
100
Engine
Diesel Outboard
SOLAS Approved
ja
Palfinger Marine Safety Palfinger Marine Safety Totally Enclosed Lifeboat 120P Diesel Outboard-C
Palfinger Marine Safety Totally Enclosed Lifeboat 120P Diesel Outboard-C unverified
Capacity (persons)
120
Engine
Diesel Outboard
SOLAS Approved
ja
Palfinger Marine Safety Palfinger Marine Safety Totally Enclosed Lifeboat 150P Diesel Outboard-C
Palfinger Marine Safety Totally Enclosed Lifeboat 150P Diesel Outboard-C unverified
Capacity (persons)
150
Engine
Diesel Outboard
SOLAS Approved
ja

Shigi Shipbuilding

31
Shigi Shipbuilding Shigi TELB-20P
Shigi TELB-20P unverified
Capacity (persons)
20
SOLAS Approved
ja
Shigi Shipbuilding Shigi TELB-25P
Shigi TELB-25P unverified
Capacity (persons)
25
SOLAS Approved
ja
Shigi Shipbuilding Shigi TELB-35P
Shigi TELB-35P unverified
Capacity (persons)
35
SOLAS Approved
ja
Shigi Shipbuilding Shigi TELB-50P
Shigi TELB-50P unverified
Capacity (persons)
50
SOLAS Approved
ja
Shigi Shipbuilding Shigi TELB-65P
Shigi TELB-65P unverified
Capacity (persons)
65
SOLAS Approved
ja
Shigi Shipbuilding Shigi TELB-80P
Shigi TELB-80P unverified
Capacity (persons)
80
SOLAS Approved
ja
Shigi Shipbuilding Shigi TELB-100P
Shigi TELB-100P unverified
Capacity (persons)
100
SOLAS Approved
ja
Shigi Shipbuilding Shigi Shipbuilding Totally Enclosed Lifeboat 6P Diesel Inboard-C
Shigi Shipbuilding Totally Enclosed Lifeboat 6P Diesel Inboard-C unverified
Capacity (persons)
6
Engine
Diesel Inboard
SOLAS Approved
ja
Shigi Shipbuilding Shigi Shipbuilding Totally Enclosed Lifeboat 10P Diesel Inboard-C
Shigi Shipbuilding Totally Enclosed Lifeboat 10P Diesel Inboard-C unverified
Capacity (persons)
10
Engine
Diesel Inboard
SOLAS Approved
ja
Shigi Shipbuilding Shigi Shipbuilding Totally Enclosed Lifeboat 16P Diesel Inboard-C
Shigi Shipbuilding Totally Enclosed Lifeboat 16P Diesel Inboard-C unverified
Capacity (persons)
16
Engine
Diesel Inboard
SOLAS Approved
ja
Shigi Shipbuilding Shigi Shipbuilding Totally Enclosed Lifeboat 20P Diesel Inboard-C
Shigi Shipbuilding Totally Enclosed Lifeboat 20P Diesel Inboard-C unverified
Capacity (persons)
20
Engine
Diesel Inboard
SOLAS Approved
ja
Shigi Shipbuilding Shigi Shipbuilding Totally Enclosed Lifeboat 25P Diesel Inboard-C
Shigi Shipbuilding Totally Enclosed Lifeboat 25P Diesel Inboard-C unverified
Capacity (persons)
25
Engine
Diesel Inboard
SOLAS Approved
ja
Shigi Shipbuilding Shigi Shipbuilding Totally Enclosed Lifeboat 35P Diesel Inboard-C
Shigi Shipbuilding Totally Enclosed Lifeboat 35P Diesel Inboard-C unverified
Capacity (persons)
35
Engine
Diesel Inboard
SOLAS Approved
ja
Shigi Shipbuilding Shigi Shipbuilding Totally Enclosed Lifeboat 50P Diesel Inboard-C
Shigi Shipbuilding Totally Enclosed Lifeboat 50P Diesel Inboard-C unverified
Capacity (persons)
50
Engine
Diesel Inboard
SOLAS Approved
ja
Shigi Shipbuilding Shigi Shipbuilding Totally Enclosed Lifeboat 65P Diesel Inboard-C
Shigi Shipbuilding Totally Enclosed Lifeboat 65P Diesel Inboard-C unverified
Capacity (persons)
65
Engine
Diesel Inboard
SOLAS Approved
ja
Shigi Shipbuilding Shigi Shipbuilding Totally Enclosed Lifeboat 80P Diesel Inboard-C
Shigi Shipbuilding Totally Enclosed Lifeboat 80P Diesel Inboard-C unverified
Capacity (persons)
80
Engine
Diesel Inboard
SOLAS Approved
ja
Shigi Shipbuilding Shigi Shipbuilding Totally Enclosed Lifeboat 100P Diesel Inboard-C
Shigi Shipbuilding Totally Enclosed Lifeboat 100P Diesel Inboard-C unverified
Capacity (persons)
100
Engine
Diesel Inboard
SOLAS Approved
ja
Shigi Shipbuilding Shigi Shipbuilding Totally Enclosed Lifeboat 120P Diesel Inboard-C
Shigi Shipbuilding Totally Enclosed Lifeboat 120P Diesel Inboard-C unverified
Capacity (persons)
120
Engine
Diesel Inboard
SOLAS Approved
ja
Shigi Shipbuilding Shigi Shipbuilding Totally Enclosed Lifeboat 150P Diesel Inboard-C
Shigi Shipbuilding Totally Enclosed Lifeboat 150P Diesel Inboard-C unverified
Capacity (persons)
150
Engine
Diesel Inboard
SOLAS Approved
ja
Shigi Shipbuilding Shigi Shipbuilding Totally Enclosed Lifeboat 6P Diesel Outboard-C
Shigi Shipbuilding Totally Enclosed Lifeboat 6P Diesel Outboard-C unverified
Capacity (persons)
6
Engine
Diesel Outboard
SOLAS Approved
ja
Shigi Shipbuilding Shigi Shipbuilding Totally Enclosed Lifeboat 10P Diesel Outboard-C
Shigi Shipbuilding Totally Enclosed Lifeboat 10P Diesel Outboard-C unverified
Capacity (persons)
10
Engine
Diesel Outboard
SOLAS Approved
ja
Shigi Shipbuilding Shigi Shipbuilding Totally Enclosed Lifeboat 16P Diesel Outboard-C
Shigi Shipbuilding Totally Enclosed Lifeboat 16P Diesel Outboard-C unverified
Capacity (persons)
16
Engine
Diesel Outboard
SOLAS Approved
ja
Shigi Shipbuilding Shigi Shipbuilding Totally Enclosed Lifeboat 20P Diesel Outboard-C
Shigi Shipbuilding Totally Enclosed Lifeboat 20P Diesel Outboard-C unverified
Capacity (persons)
20
Engine
Diesel Outboard
SOLAS Approved
ja
Shigi Shipbuilding Shigi Shipbuilding Totally Enclosed Lifeboat 25P Diesel Outboard-C
Shigi Shipbuilding Totally Enclosed Lifeboat 25P Diesel Outboard-C unverified
Capacity (persons)
25
Engine
Diesel Outboard
SOLAS Approved
ja
Shigi Shipbuilding Shigi Shipbuilding Totally Enclosed Lifeboat 35P Diesel Outboard-C
Shigi Shipbuilding Totally Enclosed Lifeboat 35P Diesel Outboard-C unverified
Capacity (persons)
35
Engine
Diesel Outboard
SOLAS Approved
ja
Shigi Shipbuilding Shigi Shipbuilding Totally Enclosed Lifeboat 50P Diesel Outboard-C
Shigi Shipbuilding Totally Enclosed Lifeboat 50P Diesel Outboard-C unverified
Capacity (persons)
50
Engine
Diesel Outboard
SOLAS Approved
ja
Shigi Shipbuilding Shigi Shipbuilding Totally Enclosed Lifeboat 65P Diesel Outboard-C
Shigi Shipbuilding Totally Enclosed Lifeboat 65P Diesel Outboard-C unverified
Capacity (persons)
65
Engine
Diesel Outboard
SOLAS Approved
ja
Shigi Shipbuilding Shigi Shipbuilding Totally Enclosed Lifeboat 80P Diesel Outboard-C
Shigi Shipbuilding Totally Enclosed Lifeboat 80P Diesel Outboard-C unverified
Capacity (persons)
80
Engine
Diesel Outboard
SOLAS Approved
ja
Shigi Shipbuilding Shigi Shipbuilding Totally Enclosed Lifeboat 100P Diesel Outboard-C
Shigi Shipbuilding Totally Enclosed Lifeboat 100P Diesel Outboard-C unverified
Capacity (persons)
100
Engine
Diesel Outboard
SOLAS Approved
ja
Shigi Shipbuilding Shigi Shipbuilding Totally Enclosed Lifeboat 120P Diesel Outboard-C
Shigi Shipbuilding Totally Enclosed Lifeboat 120P Diesel Outboard-C unverified
Capacity (persons)
120
Engine
Diesel Outboard
SOLAS Approved
ja
Shigi Shipbuilding Shigi Shipbuilding Totally Enclosed Lifeboat 150P Diesel Outboard-C
Shigi Shipbuilding Totally Enclosed Lifeboat 150P Diesel Outboard-C unverified
Capacity (persons)
150
Engine
Diesel Outboard
SOLAS Approved
ja

Hatecke

30
Hatecke Hatecke TELB-25
Hatecke TELB-25 unverified
Capacity (persons)
25
SOLAS Approved
ja
Hatecke Hatecke TELB-35
Hatecke TELB-35 unverified
Capacity (persons)
35
SOLAS Approved
ja
Hatecke Hatecke TELB-50
Hatecke TELB-50 unverified
Capacity (persons)
50
SOLAS Approved
ja
Hatecke Hatecke TELB-70
Hatecke TELB-70 unverified
Capacity (persons)
70
SOLAS Approved
ja
Hatecke Hatecke TELB-100
Hatecke TELB-100 unverified
Capacity (persons)
100
SOLAS Approved
ja
Hatecke Hatecke TELB-150
Hatecke TELB-150 unverified
Capacity (persons)
150
SOLAS Approved
ja
Hatecke Hatecke Totally Enclosed Lifeboat 6P Diesel Inboard-C
Hatecke Totally Enclosed Lifeboat 6P Diesel Inboard-C unverified
Capacity (persons)
6
Engine
Diesel Inboard
SOLAS Approved
ja
Hatecke Hatecke Totally Enclosed Lifeboat 10P Diesel Inboard-C
Hatecke Totally Enclosed Lifeboat 10P Diesel Inboard-C unverified
Capacity (persons)
10
Engine
Diesel Inboard
SOLAS Approved
ja
Hatecke Hatecke Totally Enclosed Lifeboat 16P Diesel Inboard-C
Hatecke Totally Enclosed Lifeboat 16P Diesel Inboard-C unverified
Capacity (persons)
16
Engine
Diesel Inboard
SOLAS Approved
ja
Hatecke Hatecke Totally Enclosed Lifeboat 20P Diesel Inboard-C
Hatecke Totally Enclosed Lifeboat 20P Diesel Inboard-C unverified
Capacity (persons)
20
Engine
Diesel Inboard
SOLAS Approved
ja
Hatecke Hatecke Totally Enclosed Lifeboat 25P Diesel Inboard-C
Hatecke Totally Enclosed Lifeboat 25P Diesel Inboard-C unverified
Capacity (persons)
25
Engine
Diesel Inboard
SOLAS Approved
ja
Hatecke Hatecke Totally Enclosed Lifeboat 35P Diesel Inboard-C
Hatecke Totally Enclosed Lifeboat 35P Diesel Inboard-C unverified
Capacity (persons)
35
Engine
Diesel Inboard
SOLAS Approved
ja
Hatecke Hatecke Totally Enclosed Lifeboat 50P Diesel Inboard-C
Hatecke Totally Enclosed Lifeboat 50P Diesel Inboard-C unverified
Capacity (persons)
50
Engine
Diesel Inboard
SOLAS Approved
ja
Hatecke Hatecke Totally Enclosed Lifeboat 65P Diesel Inboard-C
Hatecke Totally Enclosed Lifeboat 65P Diesel Inboard-C unverified
Capacity (persons)
65
Engine
Diesel Inboard
SOLAS Approved
ja
Hatecke Hatecke Totally Enclosed Lifeboat 80P Diesel Inboard-C
Hatecke Totally Enclosed Lifeboat 80P Diesel Inboard-C unverified
Capacity (persons)
80
Engine
Diesel Inboard
SOLAS Approved
ja
Hatecke Hatecke Totally Enclosed Lifeboat 100P Diesel Inboard-C
Hatecke Totally Enclosed Lifeboat 100P Diesel Inboard-C unverified
Capacity (persons)
100
Engine
Diesel Inboard
SOLAS Approved
ja
Hatecke Hatecke Totally Enclosed Lifeboat 120P Diesel Inboard-C
Hatecke Totally Enclosed Lifeboat 120P Diesel Inboard-C unverified
Capacity (persons)
120
Engine
Diesel Inboard
SOLAS Approved
ja
Hatecke Hatecke Totally Enclosed Lifeboat 150P Diesel Inboard-C
Hatecke Totally Enclosed Lifeboat 150P Diesel Inboard-C unverified
Capacity (persons)
150
Engine
Diesel Inboard
SOLAS Approved
ja
Hatecke Hatecke Totally Enclosed Lifeboat 6P Diesel Outboard-C
Hatecke Totally Enclosed Lifeboat 6P Diesel Outboard-C unverified
Capacity (persons)
6
Engine
Diesel Outboard
SOLAS Approved
ja
Hatecke Hatecke Totally Enclosed Lifeboat 10P Diesel Outboard-C
Hatecke Totally Enclosed Lifeboat 10P Diesel Outboard-C unverified
Capacity (persons)
10
Engine
Diesel Outboard
SOLAS Approved
ja
Hatecke Hatecke Totally Enclosed Lifeboat 16P Diesel Outboard-C
Hatecke Totally Enclosed Lifeboat 16P Diesel Outboard-C unverified
Capacity (persons)
16
Engine
Diesel Outboard
SOLAS Approved
ja
Hatecke Hatecke Totally Enclosed Lifeboat 20P Diesel Outboard-C
Hatecke Totally Enclosed Lifeboat 20P Diesel Outboard-C unverified
Capacity (persons)
20
Engine
Diesel Outboard
SOLAS Approved
ja
Hatecke Hatecke Totally Enclosed Lifeboat 25P Diesel Outboard-C
Hatecke Totally Enclosed Lifeboat 25P Diesel Outboard-C unverified
Capacity (persons)
25
Engine
Diesel Outboard
SOLAS Approved
ja
Hatecke Hatecke Totally Enclosed Lifeboat 35P Diesel Outboard-C
Hatecke Totally Enclosed Lifeboat 35P Diesel Outboard-C unverified
Capacity (persons)
35
Engine
Diesel Outboard
SOLAS Approved
ja
Hatecke Hatecke Totally Enclosed Lifeboat 50P Diesel Outboard-C
Hatecke Totally Enclosed Lifeboat 50P Diesel Outboard-C unverified
Capacity (persons)
50
Engine
Diesel Outboard
SOLAS Approved
ja
Hatecke Hatecke Totally Enclosed Lifeboat 65P Diesel Outboard-C
Hatecke Totally Enclosed Lifeboat 65P Diesel Outboard-C unverified
Capacity (persons)
65
Engine
Diesel Outboard
SOLAS Approved
ja
Hatecke Hatecke Totally Enclosed Lifeboat 80P Diesel Outboard-C
Hatecke Totally Enclosed Lifeboat 80P Diesel Outboard-C unverified
Capacity (persons)
80
Engine
Diesel Outboard
SOLAS Approved
ja
Hatecke Hatecke Totally Enclosed Lifeboat 100P Diesel Outboard-C
Hatecke Totally Enclosed Lifeboat 100P Diesel Outboard-C unverified
Capacity (persons)
100
Engine
Diesel Outboard
SOLAS Approved
ja
Hatecke Hatecke Totally Enclosed Lifeboat 120P Diesel Outboard-C
Hatecke Totally Enclosed Lifeboat 120P Diesel Outboard-C unverified
Capacity (persons)
120
Engine
Diesel Outboard
SOLAS Approved
ja
Hatecke Hatecke Totally Enclosed Lifeboat 150P Diesel Outboard-C
Hatecke Totally Enclosed Lifeboat 150P Diesel Outboard-C unverified
Capacity (persons)
150
Engine
Diesel Outboard
SOLAS Approved
ja

Verhoef

23
Verhoef Verhoef V-15P
Verhoef V-15P unverified
Capacity (persons)
15
SOLAS Approved
ja
Verhoef Verhoef V-20P
Verhoef V-20P unverified
Capacity (persons)
20
SOLAS Approved
ja
Verhoef Verhoef V-25P
Verhoef V-25P unverified
Capacity (persons)
25
SOLAS Approved
ja
Verhoef Verhoef V-35P
Verhoef V-35P unverified
Capacity (persons)
35
SOLAS Approved
ja
Verhoef Verhoef V-50P
Verhoef V-50P unverified
Capacity (persons)
50
SOLAS Approved
ja
Verhoef Verhoef V-65P
Verhoef V-65P unverified
Capacity (persons)
65
SOLAS Approved
ja
Verhoef Verhoef V-75P
Verhoef V-75P unverified
Capacity (persons)
75
SOLAS Approved
ja
Verhoef Verhoef Totally Enclosed Lifeboat 6P Diesel Inboard-C
Verhoef Totally Enclosed Lifeboat 6P Diesel Inboard-C unverified
Capacity (persons)
6
Engine
Diesel Inboard
SOLAS Approved
ja
Verhoef Verhoef Totally Enclosed Lifeboat 10P Diesel Inboard-C
Verhoef Totally Enclosed Lifeboat 10P Diesel Inboard-C unverified
Capacity (persons)
10
Engine
Diesel Inboard
SOLAS Approved
ja
Verhoef Verhoef Totally Enclosed Lifeboat 16P Diesel Inboard-C
Verhoef Totally Enclosed Lifeboat 16P Diesel Inboard-C unverified
Capacity (persons)
16
Engine
Diesel Inboard
SOLAS Approved
ja
Verhoef Verhoef Totally Enclosed Lifeboat 20P Diesel Inboard-C
Verhoef Totally Enclosed Lifeboat 20P Diesel Inboard-C unverified
Capacity (persons)
20
Engine
Diesel Inboard
SOLAS Approved
ja
Verhoef Verhoef Totally Enclosed Lifeboat 25P Diesel Inboard-C
Verhoef Totally Enclosed Lifeboat 25P Diesel Inboard-C unverified
Capacity (persons)
25
Engine
Diesel Inboard
SOLAS Approved
ja
Verhoef Verhoef Totally Enclosed Lifeboat 35P Diesel Inboard-C
Verhoef Totally Enclosed Lifeboat 35P Diesel Inboard-C unverified
Capacity (persons)
35
Engine
Diesel Inboard
SOLAS Approved
ja
Verhoef Verhoef Totally Enclosed Lifeboat 50P Diesel Inboard-C
Verhoef Totally Enclosed Lifeboat 50P Diesel Inboard-C unverified
Capacity (persons)
50
Engine
Diesel Inboard
SOLAS Approved
ja
Verhoef Verhoef Totally Enclosed Lifeboat 65P Diesel Inboard-C
Verhoef Totally Enclosed Lifeboat 65P Diesel Inboard-C unverified
Capacity (persons)
65
Engine
Diesel Inboard
SOLAS Approved
ja
Verhoef Verhoef Totally Enclosed Lifeboat 6P Diesel Outboard-C
Verhoef Totally Enclosed Lifeboat 6P Diesel Outboard-C unverified
Capacity (persons)
6
Engine
Diesel Outboard
SOLAS Approved
ja
Verhoef Verhoef Totally Enclosed Lifeboat 10P Diesel Outboard-C
Verhoef Totally Enclosed Lifeboat 10P Diesel Outboard-C unverified
Capacity (persons)
10
Engine
Diesel Outboard
SOLAS Approved
ja
Verhoef Verhoef Totally Enclosed Lifeboat 16P Diesel Outboard-C
Verhoef Totally Enclosed Lifeboat 16P Diesel Outboard-C unverified
Capacity (persons)
16
Engine
Diesel Outboard
SOLAS Approved
ja
Verhoef Verhoef Totally Enclosed Lifeboat 20P Diesel Outboard-C
Verhoef Totally Enclosed Lifeboat 20P Diesel Outboard-C unverified
Capacity (persons)
20
Engine
Diesel Outboard
SOLAS Approved
ja
Verhoef Verhoef Totally Enclosed Lifeboat 25P Diesel Outboard-C
Verhoef Totally Enclosed Lifeboat 25P Diesel Outboard-C unverified
Capacity (persons)
25
Engine
Diesel Outboard
SOLAS Approved
ja
Verhoef Verhoef Totally Enclosed Lifeboat 35P Diesel Outboard-C
Verhoef Totally Enclosed Lifeboat 35P Diesel Outboard-C unverified
Capacity (persons)
35
Engine
Diesel Outboard
SOLAS Approved
ja
Verhoef Verhoef Totally Enclosed Lifeboat 50P Diesel Outboard-C
Verhoef Totally Enclosed Lifeboat 50P Diesel Outboard-C unverified
Capacity (persons)
50
Engine
Diesel Outboard
SOLAS Approved
ja
Verhoef Verhoef Totally Enclosed Lifeboat 65P Diesel Outboard-C
Verhoef Totally Enclosed Lifeboat 65P Diesel Outboard-C unverified
Capacity (persons)
65
Engine
Diesel Outboard
SOLAS Approved
ja