15 ppm OWS
A 15 ppm OWS is the specific bilge water treatment train sized to hold outlet oil content under 15 ppm continuously, with a monitor that automatically stops discharge the moment it drifts over the limit, rather than just alarming.
Read more — 15 ppm OWS explained ▾
What makes a 15 ppm unit different
Every oily water separator on a ship is designed to bring bilge water below a legal oil content limit before it reaches the overboard valve, but the "15 ppm" designation is specific: it names the separator built and certified to hold outlet oil content under 15 parts per million continuously, verified by an inline oil content monitor rather than by periodic sampling. Older 100 ppm bilge separators still exist on some vessels under grandfather clauses, but any newbuild or retrofit fitted after the relevant MEPC amendment must meet the 15 ppm standard with a monitor that stops discharge automatically, not just an alarm a watchkeeper could silence.
Main components
Gravity/coalescing first stage
Bilge water enters a settling chamber where free oil separates by density difference and rises to a collection zone. Coalescing plates or packs increase the surface area available for small droplets to combine into larger ones that rise faster, cutting the residence time needed for a given oil removal rate.
Second stage (fine filter or coalescer)
A second unit, either a stacked coalescer, a fine mechanical filter, or in some designs a chemical/absorption cartridge, removes the emulsified and dissolved fraction the first stage cannot touch. This stage decides whether the unit can reliably hit 15 ppm on real, emulsified engine room bilge water rather than clean test water.
Oil content monitor (OCM)
An in-line monitor, usually optical, continuously measures the treated water and automatically diverts the discharge back to the bilge holding tank the instant the reading approaches 15 ppm. The monitor is a separately type-approved instrument under its own certificate, distinct from the separator's own approval.
Automatic stopping/diverting device
A three-way valve or pump-stop function, driven by the OCM, is mandatory: the system must fail safe to recirculation, not to sea.
Selection and sizing
Capacity is rated in cubic metres per hour and chosen against the bilge pumping rate of the engine room bilge system, not vessel size alone. Key figures against the specification: rated throughput, maximum inlet oil concentration the unit is designed for (raw bilge runs far dirtier than the 15 ppm limit), and the type approval certificate number referencing the applicable IMO resolution. Internals in way of the bilge pump discharge are usually stainless steel or coated carbon steel, since bilge water carries detergents, fuel residue, and sometimes seawater.
Regulations and class
- MARPOL Annex I, Regulation 14, sets the 15 ppm discharge limit and requires approved oil filtering (separating) equipment with alarm.
- IMO Resolution MEPC.107(49) is the current test and approval standard for 15 ppm separators fitted from 2005 onward, superseding MEPC.60(33).
- The oil content meter is approved separately, and class checks its calibration and alarm/stop function during survey.
- Every discharge and any equipment failure must be logged in the Oil Record Book (Part I), which flag administrations and port state control check closely.
Typical faults
| Fault | Consequence |
|---|---|
| Coalescer media fouled with sludge or detergent residue | Rising differential pressure, falling separation efficiency, eventual automatic stop on every cycle |
| OCM optical cell dirty or miscalibrated | False stops (nuisance recirculation) or, worse, false-clean readings that mask an actual overboard discharge violation |
| Emulsified bilge water from heavy detergent use during tank cleaning | Unit cannot meet 15 ppm regardless of condition; this is an operational cause, not equipment failure |
| Three-way valve stuck or bypassed manually | Untreated water can reach the overboard discharge, the classic MARPOL violation scenario investigated by port state control |
What to look for in a supplier
- Current type approval certificate referencing MEPC.107(49), matched to the flag state the vessel trades under.
- Coalescer element and OCM spares reachable through a network at the ports the vessel actually calls, not just the maker's home port.
- Documented performance on real bilge water, not only on the standard test oil/water mixture used for certification.
- OCM compatibility with any bilge water monitoring system already fitted, to avoid a costly retrofit of the electronic interface.
Never accept an OCM reading at face value if the sight glass shows visible sheen; port state control inspectors know the bypass tricks, and a falsified oil record book is a career-ending finding, not a minor deficiency.
44 manufacturers · 161 models
Alfa Laval
46
- Durchsatz (PureBilge 2515)
- 2.500 l/h
- Durchsatz (PureBilge 5015)
- 5.000 l/h
- Separator-drehzahl
- 8.000 rpm
- Ölgehalt Ausgabe (typisch)
- <5 ppm (MARPOL-Limit: 15 ppm)
- Filtermedium
- Vorwärmefilter + Koalescenteinsätze
- Prozessregler
- EPC 60/70 (computergestützt, mit Cybersecurity)
- PureBilge 2515 (2500 l/h, 15ppm)
- PureBilge 5015 (5000 l/h, 15ppm)
- PureBilge Compact 0605 (600 l/h, 5ppm)
- Area: 15ppm-Ölgehalt-Monitor (Optical Cell) Verschmutzung/KalibrierungCheck: Visual: Check optical cell for fouling; Function test via high-oil simulation (monthly); Calibration by authorized manufacturer agent every 12 months or before IOPP renewal survey (MEPC.107(49) § 4.2.11 requirement)
- Area: Coalescer inserts (filter/coalescer) blockage, wear or degradationCheck: Routine inspection: Weekly check filter/coalescer elements for wear, clogging or damage; Replace upon blockage or visible wear (planned maintenance). Internal inspection: Clear separator chamber and inspect coalescer inserts for aging
- Area: Three-way valve (changeover valve) position and functionCheck: Daily: Check all valve positions; Monthly: Test three-way valve under simulated high-oil condition to confirm diversion to slop tank; Check for leakage at flange connections; Actuation without delay or abnormal noise
- Area: Process controller (EPC 60/70) alarms, data logging and sensor functionsCheck: Weekly: Check all sensors (temperature, pressure, speed) for functionality; Monthly: Check data logging device and review log data; Quarterly: Test all alarms and sensor outputs (document with protocol); Annually: Verify sensor calibration
- Area: Piping and flange connections: Leakage and corrosionCheck: Daily: Visually inspect all pipes and valve connections for oil film, droplet formation or corrosion (especially hot water/drain areas); Weekly: Check flanges for reduction in clamping force or leakage under load; Immediately repair if signs of corrosion or leakage appear
- Area: Heater (if electrical) and preheating to setpoint temperatureCheck: Daily: Check outlet temperature of preheated bilge water (typical: 50-70°C, manufacturer-specific); Weekly: Inspect heating element surface for deposits, wear or charring; Monthly: Calibrate thermostats and temperature sensors; If setpoint temperature is not reached, check thermocouple or controller
Type-universal inspection/maintenance points for oily water separator (Alfa Laval, Mega-Schwarm 2026-06). Per-model specs not auto-filled.
- High processing capacity – up to 5 000 L/h (PureBilge 5015) while staying below the 15 ppm MARPOL limit
- Integrated EPC 60/70 controller with cyber‑security features and full data logging for audit trails
- Compact footprint and modular design suitable for retrofits on existing vessels
- Coalescent pre‑filter plus pre‑heater improves oil droplet capture efficiency, often achieving <5 ppm discharge
- Well‑documented maintenance schedule (optical cell calibration, membrane replacement) supporting predictable OPEX
- Membrane elements require replacement every 12–18 months, adding recurring cost and downtime
- Optical oil‑content sensor is sensitive to fouling; frequent calibration/verification needed to stay compliant
- Pre‑heater draws significant electrical power (typically 5–8 kW) which may be a concern on low‑power vessels
- System is optimized for bilge water only – not suitable for high‑viscosity sludges or other oily waste streams
- Initial capital outlay is higher than basic centrifugal OWS units
- Durchsatz (PureBilge 2515)
- 2.500 l/h
- Durchsatz (PureBilge 5015)
- 5.000 l/h
- Separator-drehzahl
- 8.000 rpm
- Ölgehalt Ausgabe (typisch)
- <5 ppm (MARPOL-Limit: 15 ppm)
- Filtermedium
- Vorwärmefilter + Koalescenteinsätze
- Prozessregler
- EPC 60/70 (computergestützt, mit Cybersecurity)
- PureBilge 2515 (2500 l/h, 15ppm)
- PureBilge 5015 (5000 l/h, 15ppm)
- PureBilge Compact 0605 (600 l/h, 5ppm)
- Area: 15ppm-Ölgehalt-Monitor (Optical Cell) Verschmutzung/KalibrierungCheck: Visual: Check optical cell for fouling; Function test via high-oil simulation (monthly); Calibration by authorized manufacturer agent every 12 months or before IOPP renewal survey (MEPC.107(49) § 4.2.11 requirement)
- Area: Coalescer inserts (filter/coalescer) blockage, wear or degradationCheck: Routine inspection: Weekly check filter/coalescer elements for wear, clogging or damage; Replace upon blockage or visible wear (planned maintenance). Internal inspection: Clear separator chamber and inspect coalescer inserts for aging
- Area: Three-way valve (changeover valve) position and functionCheck: Daily: Check all valve positions; Monthly: Test three-way valve under simulated high-oil condition to confirm diversion to slop tank; Check for leakage at flange connections; Actuation without delay or abnormal noise
- Area: Process controller (EPC 60/70) alarms, data logging and sensor functionsCheck: Weekly: Check all sensors (temperature, pressure, speed) for functionality; Monthly: Check data logging device and review log data; Quarterly: Test all alarms and sensor outputs (document with protocol); Annually: Verify sensor calibration
- Area: Piping and flange connections: Leakage and corrosionCheck: Daily: Visually inspect all pipes and valve connections for oil film, droplet formation or corrosion (especially hot water/drain areas); Weekly: Check flanges for reduction in clamping force or leakage under load; Immediately repair if signs of corrosion or leakage appear
- Area: Heater (if electrical) and preheating to setpoint temperatureCheck: Daily: Check outlet temperature of preheated bilge water (typical: 50-70°C, manufacturer-specific); Weekly: Inspect heating element surface for deposits, wear or charring; Monthly: Calibrate thermostats and temperature sensors; If setpoint temperature is not reached, check thermocouple or controller
Type-universal inspection/maintenance points for oily water separator (Alfa Laval, Mega-Schwarm 2026-06). Per-model specs not auto-filled.
- Durchsatz (PureBilge 2515)
- 2.500 l/h
- Durchsatz (PureBilge 5015)
- 5.000 l/h
- Separator-drehzahl
- 8.000 rpm
- Ölgehalt Ausgabe (typisch)
- <5 ppm (MARPOL-Limit: 15 ppm)
- Filtermedium
- Vorwärmefilter + Koalescenteinsätze
- Prozessregler
- EPC 60/70 (computergestützt, mit Cybersecurity)
- PureBilge 2515 (2500 l/h, 15ppm)
- PureBilge 5015 (5000 l/h, 15ppm)
- PureBilge Compact 0605 (600 l/h, 5ppm)
- Area: 15ppm-Ölgehalt-Monitor (Optical Cell) Verschmutzung/KalibrierungCheck: Visual: Check optical cell for fouling; Function test via high-oil simulation (monthly); Calibration by authorized manufacturer agent every 12 months or before IOPP renewal survey (MEPC.107(49) § 4.2.11 requirement)
- Area: Coalescer inserts (filter/coalescer) blockage, wear or degradationCheck: Routine inspection: Weekly check filter/coalescer elements for wear, clogging or damage; Replace upon blockage or visible wear (planned maintenance). Internal inspection: Clear separator chamber and inspect coalescer inserts for aging
- Area: Three-way valve (changeover valve) position and functionCheck: Daily: Check all valve positions; Monthly: Test three-way valve under simulated high-oil condition to confirm diversion to slop tank; Check for leakage at flange connections; Actuation without delay or abnormal noise
- Area: Process controller (EPC 60/70) alarms, data logging and sensor functionsCheck: Weekly: Check all sensors (temperature, pressure, speed) for functionality; Monthly: Check data logging device and review log data; Quarterly: Test all alarms and sensor outputs (document with protocol); Annually: Verify sensor calibration
- Area: Piping and flange connections: Leakage and corrosionCheck: Daily: Visually inspect all pipes and valve connections for oil film, droplet formation or corrosion (especially hot water/drain areas); Weekly: Check flanges for reduction in clamping force or leakage under load; Immediately repair if signs of corrosion or leakage appear
- Area: Heater (if electrical) and preheating to setpoint temperatureCheck: Daily: Check outlet temperature of preheated bilge water (typical: 50-70°C, manufacturer-specific); Weekly: Inspect heating element surface for deposits, wear or charring; Monthly: Calibrate thermostats and temperature sensors; If setpoint temperature is not reached, check thermocouple or controller
Type-universal inspection/maintenance points for oily water separator (Alfa Laval, Mega-Schwarm 2026-06). Per-model specs not auto-filled.
- Durchsatz (PureBilge 2515)
- 2.500 l/h
- Durchsatz (PureBilge 5015)
- 5.000 l/h
- Separator-drehzahl
- 8.000 rpm
- Ölgehalt Ausgabe (typisch)
- <5 ppm (MARPOL-Limit: 15 ppm)
- Filtermedium
- Vorwärmefilter + Koalescenteinsätze
- Prozessregler
- EPC 60/70 (computergestützt, mit Cybersecurity)
- PureBilge 2515 (2500 l/h, 15ppm)
- PureBilge 5015 (5000 l/h, 15ppm)
- PureBilge Compact 0605 (600 l/h, 5ppm)
- Area: 15ppm-Ölgehalt-Monitor (Optical Cell) Verschmutzung/KalibrierungCheck: Visual: Check optical cell for fouling; Function test via high-oil simulation (monthly); Calibration by authorized manufacturer agent every 12 months or before IOPP renewal survey (MEPC.107(49) § 4.2.11 requirement)
- Area: Coalescer inserts (filter/coalescer) blockage, wear or degradationCheck: Routine inspection: Weekly check filter/coalescer elements for wear, clogging or damage; Replace upon blockage or visible wear (planned maintenance). Internal inspection: Clear separator chamber and inspect coalescer inserts for aging
- Area: Three-way valve (changeover valve) position and functionCheck: Daily: Check all valve positions; Monthly: Test three-way valve under simulated high-oil condition to confirm diversion to slop tank; Check for leakage at flange connections; Actuation without delay or abnormal noise
- Area: Process controller (EPC 60/70) alarms, data logging and sensor functionsCheck: Weekly: Check all sensors (temperature, pressure, speed) for functionality; Monthly: Check data logging device and review log data; Quarterly: Test all alarms and sensor outputs (document with protocol); Annually: Verify sensor calibration
- Area: Piping and flange connections: Leakage and corrosionCheck: Daily: Visually inspect all pipes and valve connections for oil film, droplet formation or corrosion (especially hot water/drain areas); Weekly: Check flanges for reduction in clamping force or leakage under load; Immediately repair if signs of corrosion or leakage appear
- Area: Heater (if electrical) and preheating to setpoint temperatureCheck: Daily: Check outlet temperature of preheated bilge water (typical: 50-70°C, manufacturer-specific); Weekly: Inspect heating element surface for deposits, wear or charring; Monthly: Calibrate thermostats and temperature sensors; If setpoint temperature is not reached, check thermocouple or controller
Type-universal inspection/maintenance points for oily water separator (Alfa Laval, Mega-Schwarm 2026-06). Per-model specs not auto-filled.
- Durchsatz (PureBilge 2515)
- 2.500 l/h
- Durchsatz (PureBilge 5015)
- 5.000 l/h
- Separator-drehzahl
- 8.000 rpm
- Ölgehalt Ausgabe (typisch)
- <5 ppm (MARPOL-Limit: 15 ppm)
- Filtermedium
- Vorwärmefilter + Koalescenteinsätze
- Prozessregler
- EPC 60/70 (computergestützt, mit Cybersecurity)
- PureBilge 2515 (2500 l/h, 15ppm)
- PureBilge 5015 (5000 l/h, 15ppm)
- PureBilge Compact 0605 (600 l/h, 5ppm)
- Area: 15ppm-Ölgehalt-Monitor (Optical Cell) Verschmutzung/KalibrierungCheck: Visual: Check optical cell for fouling; Function test via high-oil simulation (monthly); Calibration by authorized manufacturer agent every 12 months or before IOPP renewal survey (MEPC.107(49) § 4.2.11 requirement)
- Area: Coalescer inserts (filter/coalescer) blockage, wear or degradationCheck: Routine inspection: Weekly check filter/coalescer elements for wear, clogging or damage; Replace upon blockage or visible wear (planned maintenance). Internal inspection: Clear separator chamber and inspect coalescer inserts for aging
- Area: Three-way valve (changeover valve) position and functionCheck: Daily: Check all valve positions; Monthly: Test three-way valve under simulated high-oil condition to confirm diversion to slop tank; Check for leakage at flange connections; Actuation without delay or abnormal noise
- Area: Process controller (EPC 60/70) alarms, data logging and sensor functionsCheck: Weekly: Check all sensors (temperature, pressure, speed) for functionality; Monthly: Check data logging device and review log data; Quarterly: Test all alarms and sensor outputs (document with protocol); Annually: Verify sensor calibration
- Area: Piping and flange connections: Leakage and corrosionCheck: Daily: Visually inspect all pipes and valve connections for oil film, droplet formation or corrosion (especially hot water/drain areas); Weekly: Check flanges for reduction in clamping force or leakage under load; Immediately repair if signs of corrosion or leakage appear
- Area: Heater (if electrical) and preheating to setpoint temperatureCheck: Daily: Check outlet temperature of preheated bilge water (typical: 50-70°C, manufacturer-specific); Weekly: Inspect heating element surface for deposits, wear or charring; Monthly: Calibrate thermostats and temperature sensors; If setpoint temperature is not reached, check thermocouple or controller
Type-universal inspection/maintenance points for oily water separator (Alfa Laval, Mega-Schwarm 2026-06). Per-model specs not auto-filled.
- Durchsatz (PureBilge 2515)
- 2.500 l/h
- Durchsatz (PureBilge 5015)
- 5.000 l/h
- Separator-drehzahl
- 8.000 rpm
- Ölgehalt Ausgabe (typisch)
- <5 ppm (MARPOL-Limit: 15 ppm)
- Filtermedium
- Vorwärmefilter + Koalescenteinsätze
- Prozessregler
- EPC 60/70 (computergestützt, mit Cybersecurity)
- PureBilge 2515 (2500 l/h, 15ppm)
- PureBilge 5015 (5000 l/h, 15ppm)
- PureBilge Compact 0605 (600 l/h, 5ppm)
- Area: 15ppm-Ölgehalt-Monitor (Optical Cell) Verschmutzung/KalibrierungCheck: Visual: Check optical cell for fouling; Function test via high-oil simulation (monthly); Calibration by authorized manufacturer agent every 12 months or before IOPP renewal survey (MEPC.107(49) § 4.2.11 requirement)
- Area: Coalescer inserts (filter/coalescer) blockage, wear or degradationCheck: Routine inspection: Weekly check filter/coalescer elements for wear, clogging or damage; Replace upon blockage or visible wear (planned maintenance). Internal inspection: Clear separator chamber and inspect coalescer inserts for aging
- Area: Three-way valve (changeover valve) position and functionCheck: Daily: Check all valve positions; Monthly: Test three-way valve under simulated high-oil condition to confirm diversion to slop tank; Check for leakage at flange connections; Actuation without delay or abnormal noise
- Area: Process controller (EPC 60/70) alarms, data logging and sensor functionsCheck: Weekly: Check all sensors (temperature, pressure, speed) for functionality; Monthly: Check data logging device and review log data; Quarterly: Test all alarms and sensor outputs (document with protocol); Annually: Verify sensor calibration
- Area: Piping and flange connections: Leakage and corrosionCheck: Daily: Visually inspect all pipes and valve connections for oil film, droplet formation or corrosion (especially hot water/drain areas); Weekly: Check flanges for reduction in clamping force or leakage under load; Immediately repair if signs of corrosion or leakage appear
- Area: Heater (if electrical) and preheating to setpoint temperatureCheck: Daily: Check outlet temperature of preheated bilge water (typical: 50-70°C, manufacturer-specific); Weekly: Inspect heating element surface for deposits, wear or charring; Monthly: Calibrate thermostats and temperature sensors; If setpoint temperature is not reached, check thermocouple or controller
Type-universal inspection/maintenance points for oily water separator (Alfa Laval, Mega-Schwarm 2026-06). Per-model specs not auto-filled.
- Durchsatz (PureBilge 2515)
- 2.500 l/h
- Durchsatz (PureBilge 5015)
- 5.000 l/h
- Separator-drehzahl
- 8.000 rpm
- Ölgehalt Ausgabe (typisch)
- <5 ppm (MARPOL-Limit: 15 ppm)
- Filtermedium
- Vorwärmefilter + Koalescenteinsätze
- Prozessregler
- EPC 60/70 (computergestützt, mit Cybersecurity)
- PureBilge 2515 (2500 l/h, 15ppm)
- PureBilge 5015 (5000 l/h, 15ppm)
- PureBilge Compact 0605 (600 l/h, 5ppm)
- Area: 15ppm-Ölgehalt-Monitor (Optical Cell) Verschmutzung/KalibrierungCheck: Visual: Check optical cell for fouling; Function test via high-oil simulation (monthly); Calibration by authorized manufacturer agent every 12 months or before IOPP renewal survey (MEPC.107(49) § 4.2.11 requirement)
- Area: Coalescer inserts (filter/coalescer) blockage, wear or degradationCheck: Routine inspection: Weekly check filter/coalescer elements for wear, clogging or damage; Replace upon blockage or visible wear (planned maintenance). Internal inspection: Clear separator chamber and inspect coalescer inserts for aging
- Area: Three-way valve (changeover valve) position and functionCheck: Daily: Check all valve positions; Monthly: Test three-way valve under simulated high-oil condition to confirm diversion to slop tank; Check for leakage at flange connections; Actuation without delay or abnormal noise
- Area: Process controller (EPC 60/70) alarms, data logging and sensor functionsCheck: Weekly: Check all sensors (temperature, pressure, speed) for functionality; Monthly: Check data logging device and review log data; Quarterly: Test all alarms and sensor outputs (document with protocol); Annually: Verify sensor calibration
- Area: Piping and flange connections: Leakage and corrosionCheck: Daily: Visually inspect all pipes and valve connections for oil film, droplet formation or corrosion (especially hot water/drain areas); Weekly: Check flanges for reduction in clamping force or leakage under load; Immediately repair if signs of corrosion or leakage appear
- Area: Heater (if electrical) and preheating to setpoint temperatureCheck: Daily: Check outlet temperature of preheated bilge water (typical: 50-70°C, manufacturer-specific); Weekly: Inspect heating element surface for deposits, wear or charring; Monthly: Calibrate thermostats and temperature sensors; If setpoint temperature is not reached, check thermocouple or controller
Type-universal inspection/maintenance points for oily water separator (Alfa Laval, Mega-Schwarm 2026-06). Per-model specs not auto-filled.
- Durchsatz (PureBilge 2515)
- 2.500 l/h
- Durchsatz (PureBilge 5015)
- 5.000 l/h
- Separator-drehzahl
- 8.000 rpm
- Ölgehalt Ausgabe (typisch)
- <5 ppm (MARPOL-Limit: 15 ppm)
- Filtermedium
- Vorwärmefilter + Koalescenteinsätze
- Prozessregler
- EPC 60/70 (computergestützt, mit Cybersecurity)
- PureBilge 2515 (2500 l/h, 15ppm)
- PureBilge 5015 (5000 l/h, 15ppm)
- PureBilge Compact 0605 (600 l/h, 5ppm)
- Area: 15ppm-Ölgehalt-Monitor (Optical Cell) Verschmutzung/KalibrierungCheck: Visual: Check optical cell for fouling; Function test via high-oil simulation (monthly); Calibration by authorized manufacturer agent every 12 months or before IOPP renewal survey (MEPC.107(49) § 4.2.11 requirement)
- Area: Coalescer inserts (filter/coalescer) blockage, wear or degradationCheck: Routine inspection: Weekly check filter/coalescer elements for wear, clogging or damage; Replace upon blockage or visible wear (planned maintenance). Internal inspection: Clear separator chamber and inspect coalescer inserts for aging
- Area: Three-way valve (changeover valve) position and functionCheck: Daily: Check all valve positions; Monthly: Test three-way valve under simulated high-oil condition to confirm diversion to slop tank; Check for leakage at flange connections; Actuation without delay or abnormal noise
- Area: Process controller (EPC 60/70) alarms, data logging and sensor functionsCheck: Weekly: Check all sensors (temperature, pressure, speed) for functionality; Monthly: Check data logging device and review log data; Quarterly: Test all alarms and sensor outputs (document with protocol); Annually: Verify sensor calibration
- Area: Piping and flange connections: Leakage and corrosionCheck: Daily: Visually inspect all pipes and valve connections for oil film, droplet formation or corrosion (especially hot water/drain areas); Weekly: Check flanges for reduction in clamping force or leakage under load; Immediately repair if signs of corrosion or leakage appear
- Area: Heater (if electrical) and preheating to setpoint temperatureCheck: Daily: Check outlet temperature of preheated bilge water (typical: 50-70°C, manufacturer-specific); Weekly: Inspect heating element surface for deposits, wear or charring; Monthly: Calibrate thermostats and temperature sensors; If setpoint temperature is not reached, check thermocouple or controller
Type-universal inspection/maintenance points for oily water separator (Alfa Laval, Mega-Schwarm 2026-06). Per-model specs not auto-filled.
- Durchsatz (PureBilge 2515)
- 2.500 l/h
- Durchsatz (PureBilge 5015)
- 5.000 l/h
- Separator-drehzahl
- 8.000 rpm
- Ölgehalt Ausgabe (typisch)
- <5 ppm (MARPOL-Limit: 15 ppm)
- Filtermedium
- Vorwärmefilter + Koalescenteinsätze
- Prozessregler
- EPC 60/70 (computergestützt, mit Cybersecurity)
- PureBilge 2515 (2500 l/h, 15ppm)
- PureBilge 5015 (5000 l/h, 15ppm)
- PureBilge Compact 0605 (600 l/h, 5ppm)
- Area: 15ppm-Ölgehalt-Monitor (Optical Cell) Verschmutzung/KalibrierungCheck: Visual: Check optical cell for fouling; Function test via high-oil simulation (monthly); Calibration by authorized manufacturer agent every 12 months or before IOPP renewal survey (MEPC.107(49) § 4.2.11 requirement)
- Area: Coalescer inserts (filter/coalescer) blockage, wear or degradationCheck: Routine inspection: Weekly check filter/coalescer elements for wear, clogging or damage; Replace upon blockage or visible wear (planned maintenance). Internal inspection: Clear separator chamber and inspect coalescer inserts for aging
- Area: Three-way valve (changeover valve) position and functionCheck: Daily: Check all valve positions; Monthly: Test three-way valve under simulated high-oil condition to confirm diversion to slop tank; Check for leakage at flange connections; Actuation without delay or abnormal noise
- Area: Process controller (EPC 60/70) alarms, data logging and sensor functionsCheck: Weekly: Check all sensors (temperature, pressure, speed) for functionality; Monthly: Check data logging device and review log data; Quarterly: Test all alarms and sensor outputs (document with protocol); Annually: Verify sensor calibration
- Area: Piping and flange connections: Leakage and corrosionCheck: Daily: Visually inspect all pipes and valve connections for oil film, droplet formation or corrosion (especially hot water/drain areas); Weekly: Check flanges for reduction in clamping force or leakage under load; Immediately repair if signs of corrosion or leakage appear
- Area: Heater (if electrical) and preheating to setpoint temperatureCheck: Daily: Check outlet temperature of preheated bilge water (typical: 50-70°C, manufacturer-specific); Weekly: Inspect heating element surface for deposits, wear or charring; Monthly: Calibrate thermostats and temperature sensors; If setpoint temperature is not reached, check thermocouple or controller
Type-universal inspection/maintenance points for oily water separator (Alfa Laval, Mega-Schwarm 2026-06). Per-model specs not auto-filled.
- Durchsatz (PureBilge 2515)
- 2.500 l/h
- Durchsatz (PureBilge 5015)
- 5.000 l/h
- Separator-drehzahl
- 8.000 rpm
- Ölgehalt Ausgabe (typisch)
- <5 ppm (MARPOL-Limit: 15 ppm)
- Filtermedium
- Vorwärmefilter + Koalescenteinsätze
- Prozessregler
- EPC 60/70 (computergestützt, mit Cybersecurity)
- PureBilge 2515 (2500 l/h, 15ppm)
- PureBilge 5015 (5000 l/h, 15ppm)
- PureBilge Compact 0605 (600 l/h, 5ppm)
- Area: 15ppm-Ölgehalt-Monitor (Optical Cell) Verschmutzung/KalibrierungCheck: Visual: Check optical cell for fouling; Function test via high-oil simulation (monthly); Calibration by authorized manufacturer agent every 12 months or before IOPP renewal survey (MEPC.107(49) § 4.2.11 requirement)
- Area: Coalescer inserts (filter/coalescer) blockage, wear or degradationCheck: Routine inspection: Weekly check filter/coalescer elements for wear, clogging or damage; Replace upon blockage or visible wear (planned maintenance). Internal inspection: Clear separator chamber and inspect coalescer inserts for aging
- Area: Three-way valve (changeover valve) position and functionCheck: Daily: Check all valve positions; Monthly: Test three-way valve under simulated high-oil condition to confirm diversion to slop tank; Check for leakage at flange connections; Actuation without delay or abnormal noise
- Area: Process controller (EPC 60/70) alarms, data logging and sensor functionsCheck: Weekly: Check all sensors (temperature, pressure, speed) for functionality; Monthly: Check data logging device and review log data; Quarterly: Test all alarms and sensor outputs (document with protocol); Annually: Verify sensor calibration
- Area: Piping and flange connections: Leakage and corrosionCheck: Daily: Visually inspect all pipes and valve connections for oil film, droplet formation or corrosion (especially hot water/drain areas); Weekly: Check flanges for reduction in clamping force or leakage under load; Immediately repair if signs of corrosion or leakage appear
- Area: Heater (if electrical) and preheating to setpoint temperatureCheck: Daily: Check outlet temperature of preheated bilge water (typical: 50-70°C, manufacturer-specific); Weekly: Inspect heating element surface for deposits, wear or charring; Monthly: Calibrate thermostats and temperature sensors; If setpoint temperature is not reached, check thermocouple or controller
Type-universal inspection/maintenance points for oily water separator (Alfa Laval, Mega-Schwarm 2026-06). Per-model specs not auto-filled.
- Durchsatz (PureBilge 2515)
- 2.500 l/h
- Durchsatz (PureBilge 5015)
- 5.000 l/h
- Separator-drehzahl
- 8.000 rpm
- Ölgehalt Ausgabe (typisch)
- <5 ppm (MARPOL-Limit: 15 ppm)
- Filtermedium
- Vorwärmefilter + Koalescenteinsätze
- Prozessregler
- EPC 60/70 (computergestützt, mit Cybersecurity)
- PureBilge 2515 (2500 l/h, 15ppm)
- PureBilge 5015 (5000 l/h, 15ppm)
- PureBilge Compact 0605 (600 l/h, 5ppm)
- Area: 15ppm-Ölgehalt-Monitor (Optical Cell) Verschmutzung/KalibrierungCheck: Visual: Check optical cell for fouling; Function test via high-oil simulation (monthly); Calibration by authorized manufacturer agent every 12 months or before IOPP renewal survey (MEPC.107(49) § 4.2.11 requirement)
- Area: Coalescer inserts (filter/coalescer) blockage, wear or degradationCheck: Routine inspection: Weekly check filter/coalescer elements for wear, clogging or damage; Replace upon blockage or visible wear (planned maintenance). Internal inspection: Clear separator chamber and inspect coalescer inserts for aging
- Area: Three-way valve (changeover valve) position and functionCheck: Daily: Check all valve positions; Monthly: Test three-way valve under simulated high-oil condition to confirm diversion to slop tank; Check for leakage at flange connections; Actuation without delay or abnormal noise
- Area: Process controller (EPC 60/70) alarms, data logging and sensor functionsCheck: Weekly: Check all sensors (temperature, pressure, speed) for functionality; Monthly: Check data logging device and review log data; Quarterly: Test all alarms and sensor outputs (document with protocol); Annually: Verify sensor calibration
- Area: Piping and flange connections: Leakage and corrosionCheck: Daily: Visually inspect all pipes and valve connections for oil film, droplet formation or corrosion (especially hot water/drain areas); Weekly: Check flanges for reduction in clamping force or leakage under load; Immediately repair if signs of corrosion or leakage appear
- Area: Heater (if electrical) and preheating to setpoint temperatureCheck: Daily: Check outlet temperature of preheated bilge water (typical: 50-70°C, manufacturer-specific); Weekly: Inspect heating element surface for deposits, wear or charring; Monthly: Calibrate thermostats and temperature sensors; If setpoint temperature is not reached, check thermocouple or controller
Type-universal inspection/maintenance points for oily water separator (Alfa Laval, Mega-Schwarm 2026-06). Per-model specs not auto-filled.
- Durchsatz (PureBilge 2515)
- 2.500 l/h
- Durchsatz (PureBilge 5015)
- 5.000 l/h
- Separator-drehzahl
- 8.000 rpm
- Ölgehalt Ausgabe (typisch)
- <5 ppm (MARPOL-Limit: 15 ppm)
- Filtermedium
- Vorwärmefilter + Koalescenteinsätze
- Prozessregler
- EPC 60/70 (computergestützt, mit Cybersecurity)
- PureBilge 2515 (2500 l/h, 15ppm)
- PureBilge 5015 (5000 l/h, 15ppm)
- PureBilge Compact 0605 (600 l/h, 5ppm)
- Area: 15ppm-Ölgehalt-Monitor (Optical Cell) Verschmutzung/KalibrierungCheck: Visual: Check optical cell for fouling; Function test via high-oil simulation (monthly); Calibration by authorized manufacturer agent every 12 months or before IOPP renewal survey (MEPC.107(49) § 4.2.11 requirement)
- Area: Coalescer inserts (filter/coalescer) blockage, wear or degradationCheck: Routine inspection: Weekly check filter/coalescer elements for wear, clogging or damage; Replace upon blockage or visible wear (planned maintenance). Internal inspection: Clear separator chamber and inspect coalescer inserts for aging
- Area: Three-way valve (changeover valve) position and functionCheck: Daily: Check all valve positions; Monthly: Test three-way valve under simulated high-oil condition to confirm diversion to slop tank; Check for leakage at flange connections; Actuation without delay or abnormal noise
- Area: Process controller (EPC 60/70) alarms, data logging and sensor functionsCheck: Weekly: Check all sensors (temperature, pressure, speed) for functionality; Monthly: Check data logging device and review log data; Quarterly: Test all alarms and sensor outputs (document with protocol); Annually: Verify sensor calibration
- Area: Piping and flange connections: Leakage and corrosionCheck: Daily: Visually inspect all pipes and valve connections for oil film, droplet formation or corrosion (especially hot water/drain areas); Weekly: Check flanges for reduction in clamping force or leakage under load; Immediately repair if signs of corrosion or leakage appear
- Area: Heater (if electrical) and preheating to setpoint temperatureCheck: Daily: Check outlet temperature of preheated bilge water (typical: 50-70°C, manufacturer-specific); Weekly: Inspect heating element surface for deposits, wear or charring; Monthly: Calibrate thermostats and temperature sensors; If setpoint temperature is not reached, check thermocouple or controller
Type-universal inspection/maintenance points for oily water separator (Alfa Laval, Mega-Schwarm 2026-06). Per-model specs not auto-filled.
- Durchsatz (PureBilge 2515)
- 2.500 l/h
- Durchsatz (PureBilge 5015)
- 5.000 l/h
- Separator-drehzahl
- 8.000 rpm
- Ölgehalt Ausgabe (typisch)
- <5 ppm (MARPOL-Limit: 15 ppm)
- Filtermedium
- Vorwärmefilter + Koalescenteinsätze
- Prozessregler
- EPC 60/70 (computergestützt, mit Cybersecurity)
- PureBilge 2515 (2500 l/h, 15ppm)
- PureBilge 5015 (5000 l/h, 15ppm)
- PureBilge Compact 0605 (600 l/h, 5ppm)
- Area: 15ppm-Ölgehalt-Monitor (Optical Cell) Verschmutzung/KalibrierungCheck: Visual: Check optical cell for fouling; Function test via high-oil simulation (monthly); Calibration by authorized manufacturer agent every 12 months or before IOPP renewal survey (MEPC.107(49) § 4.2.11 requirement)
- Area: Coalescer inserts (filter/coalescer) blockage, wear or degradationCheck: Routine inspection: Weekly check filter/coalescer elements for wear, clogging or damage; Replace upon blockage or visible wear (planned maintenance). Internal inspection: Clear separator chamber and inspect coalescer inserts for aging
- Area: Three-way valve (changeover valve) position and functionCheck: Daily: Check all valve positions; Monthly: Test three-way valve under simulated high-oil condition to confirm diversion to slop tank; Check for leakage at flange connections; Actuation without delay or abnormal noise
- Area: Process controller (EPC 60/70) alarms, data logging and sensor functionsCheck: Weekly: Check all sensors (temperature, pressure, speed) for functionality; Monthly: Check data logging device and review log data; Quarterly: Test all alarms and sensor outputs (document with protocol); Annually: Verify sensor calibration
- Area: Piping and flange connections: Leakage and corrosionCheck: Daily: Visually inspect all pipes and valve connections for oil film, droplet formation or corrosion (especially hot water/drain areas); Weekly: Check flanges for reduction in clamping force or leakage under load; Immediately repair if signs of corrosion or leakage appear
- Area: Heater (if electrical) and preheating to setpoint temperatureCheck: Daily: Check outlet temperature of preheated bilge water (typical: 50-70°C, manufacturer-specific); Weekly: Inspect heating element surface for deposits, wear or charring; Monthly: Calibrate thermostats and temperature sensors; If setpoint temperature is not reached, check thermocouple or controller
Type-universal inspection/maintenance points for oily water separator (Alfa Laval, Mega-Schwarm 2026-06). Per-model specs not auto-filled.
- Durchsatz (PureBilge 2515)
- 2.500 l/h
- Durchsatz (PureBilge 5015)
- 5.000 l/h
- Separator-drehzahl
- 8.000 rpm
- Ölgehalt Ausgabe (typisch)
- <5 ppm (MARPOL-Limit: 15 ppm)
- Filtermedium
- Vorwärmefilter + Koalescenteinsätze
- Prozessregler
- EPC 60/70 (computergestützt, mit Cybersecurity)
- PureBilge 2515 (2500 l/h, 15ppm)
- PureBilge 5015 (5000 l/h, 15ppm)
- PureBilge Compact 0605 (600 l/h, 5ppm)
- Area: 15ppm-Ölgehalt-Monitor (Optical Cell) Verschmutzung/KalibrierungCheck: Visual: Check optical cell for fouling; Function test via high-oil simulation (monthly); Calibration by authorized manufacturer agent every 12 months or before IOPP renewal survey (MEPC.107(49) § 4.2.11 requirement)
- Area: Coalescer inserts (filter/coalescer) blockage, wear or degradationCheck: Routine inspection: Weekly check filter/coalescer elements for wear, clogging or damage; Replace upon blockage or visible wear (planned maintenance). Internal inspection: Clear separator chamber and inspect coalescer inserts for aging
- Area: Three-way valve (changeover valve) position and functionCheck: Daily: Check all valve positions; Monthly: Test three-way valve under simulated high-oil condition to confirm diversion to slop tank; Check for leakage at flange connections; Actuation without delay or abnormal noise
- Area: Process controller (EPC 60/70) alarms, data logging and sensor functionsCheck: Weekly: Check all sensors (temperature, pressure, speed) for functionality; Monthly: Check data logging device and review log data; Quarterly: Test all alarms and sensor outputs (document with protocol); Annually: Verify sensor calibration
- Area: Piping and flange connections: Leakage and corrosionCheck: Daily: Visually inspect all pipes and valve connections for oil film, droplet formation or corrosion (especially hot water/drain areas); Weekly: Check flanges for reduction in clamping force or leakage under load; Immediately repair if signs of corrosion or leakage appear
- Area: Heater (if electrical) and preheating to setpoint temperatureCheck: Daily: Check outlet temperature of preheated bilge water (typical: 50-70°C, manufacturer-specific); Weekly: Inspect heating element surface for deposits, wear or charring; Monthly: Calibrate thermostats and temperature sensors; If setpoint temperature is not reached, check thermocouple or controller
Type-universal inspection/maintenance points for oily water separator (Alfa Laval, Mega-Schwarm 2026-06). Per-model specs not auto-filled.
- Durchsatz (PureBilge 2515)
- 2.500 l/h
- Durchsatz (PureBilge 5015)
- 5.000 l/h
- Separator-drehzahl
- 8.000 rpm
- Ölgehalt Ausgabe (typisch)
- <5 ppm (MARPOL-Limit: 15 ppm)
- Filtermedium
- Vorwärmefilter + Koalescenteinsätze
- Prozessregler
- EPC 60/70 (computergestützt, mit Cybersecurity)
- PureBilge 2515 (2500 l/h, 15ppm)
- PureBilge 5015 (5000 l/h, 15ppm)
- PureBilge Compact 0605 (600 l/h, 5ppm)
- Area: 15ppm-Ölgehalt-Monitor (Optical Cell) Verschmutzung/KalibrierungCheck: Visual: Check optical cell for fouling; Function test via high-oil simulation (monthly); Calibration by authorized manufacturer agent every 12 months or before IOPP renewal survey (MEPC.107(49) § 4.2.11 requirement)
- Area: Coalescer inserts (filter/coalescer) blockage, wear or degradationCheck: Routine inspection: Weekly check filter/coalescer elements for wear, clogging or damage; Replace upon blockage or visible wear (planned maintenance). Internal inspection: Clear separator chamber and inspect coalescer inserts for aging
- Area: Three-way valve (changeover valve) position and functionCheck: Daily: Check all valve positions; Monthly: Test three-way valve under simulated high-oil condition to confirm diversion to slop tank; Check for leakage at flange connections; Actuation without delay or abnormal noise
- Area: Process controller (EPC 60/70) alarms, data logging and sensor functionsCheck: Weekly: Check all sensors (temperature, pressure, speed) for functionality; Monthly: Check data logging device and review log data; Quarterly: Test all alarms and sensor outputs (document with protocol); Annually: Verify sensor calibration
- Area: Piping and flange connections: Leakage and corrosionCheck: Daily: Visually inspect all pipes and valve connections for oil film, droplet formation or corrosion (especially hot water/drain areas); Weekly: Check flanges for reduction in clamping force or leakage under load; Immediately repair if signs of corrosion or leakage appear
- Area: Heater (if electrical) and preheating to setpoint temperatureCheck: Daily: Check outlet temperature of preheated bilge water (typical: 50-70°C, manufacturer-specific); Weekly: Inspect heating element surface for deposits, wear or charring; Monthly: Calibrate thermostats and temperature sensors; If setpoint temperature is not reached, check thermocouple or controller
Type-universal inspection/maintenance points for oily water separator (Alfa Laval, Mega-Schwarm 2026-06). Per-model specs not auto-filled.
- Durchsatz (PureBilge 2515)
- 2.500 l/h
- Durchsatz (PureBilge 5015)
- 5.000 l/h
- Separator-drehzahl
- 8.000 rpm
- Ölgehalt Ausgabe (typisch)
- <5 ppm (MARPOL-Limit: 15 ppm)
- Filtermedium
- Vorwärmefilter + Koalescenteinsätze
- Prozessregler
- EPC 60/70 (computergestützt, mit Cybersecurity)
- PureBilge 2515 (2500 l/h, 15ppm)
- PureBilge 5015 (5000 l/h, 15ppm)
- PureBilge Compact 0605 (600 l/h, 5ppm)
- Area: 15ppm-Ölgehalt-Monitor (Optical Cell) Verschmutzung/KalibrierungCheck: Visual: Check optical cell for fouling; Function test via high-oil simulation (monthly); Calibration by authorized manufacturer agent every 12 months or before IOPP renewal survey (MEPC.107(49) § 4.2.11 requirement)
- Area: Coalescer inserts (filter/coalescer) blockage, wear or degradationCheck: Routine inspection: Weekly check filter/coalescer elements for wear, clogging or damage; Replace upon blockage or visible wear (planned maintenance). Internal inspection: Clear separator chamber and inspect coalescer inserts for aging
- Area: Three-way valve (changeover valve) position and functionCheck: Daily: Check all valve positions; Monthly: Test three-way valve under simulated high-oil condition to confirm diversion to slop tank; Check for leakage at flange connections; Actuation without delay or abnormal noise
- Area: Process controller (EPC 60/70) alarms, data logging and sensor functionsCheck: Weekly: Check all sensors (temperature, pressure, speed) for functionality; Monthly: Check data logging device and review log data; Quarterly: Test all alarms and sensor outputs (document with protocol); Annually: Verify sensor calibration
- Area: Piping and flange connections: Leakage and corrosionCheck: Daily: Visually inspect all pipes and valve connections for oil film, droplet formation or corrosion (especially hot water/drain areas); Weekly: Check flanges for reduction in clamping force or leakage under load; Immediately repair if signs of corrosion or leakage appear
- Area: Heater (if electrical) and preheating to setpoint temperatureCheck: Daily: Check outlet temperature of preheated bilge water (typical: 50-70°C, manufacturer-specific); Weekly: Inspect heating element surface for deposits, wear or charring; Monthly: Calibrate thermostats and temperature sensors; If setpoint temperature is not reached, check thermocouple or controller
Type-universal inspection/maintenance points for oily water separator (Alfa Laval, Mega-Schwarm 2026-06). Per-model specs not auto-filled.
- Durchsatz (PureBilge 2515)
- 2.500 l/h
- Durchsatz (PureBilge 5015)
- 5.000 l/h
- Separator-drehzahl
- 8.000 rpm
- Ölgehalt Ausgabe (typisch)
- <5 ppm (MARPOL-Limit: 15 ppm)
- Filtermedium
- Vorwärmefilter + Koalescenteinsätze
- Prozessregler
- EPC 60/70 (computergestützt, mit Cybersecurity)
- PureBilge 2515 (2500 l/h, 15ppm)
- PureBilge 5015 (5000 l/h, 15ppm)
- PureBilge Compact 0605 (600 l/h, 5ppm)
- Area: 15ppm-Ölgehalt-Monitor (Optical Cell) Verschmutzung/KalibrierungCheck: Visual: Check optical cell for fouling; Function test via high-oil simulation (monthly); Calibration by authorized manufacturer agent every 12 months or before IOPP renewal survey (MEPC.107(49) § 4.2.11 requirement)
- Area: Coalescer inserts (filter/coalescer) blockage, wear or degradationCheck: Routine inspection: Weekly check filter/coalescer elements for wear, clogging or damage; Replace upon blockage or visible wear (planned maintenance). Internal inspection: Clear separator chamber and inspect coalescer inserts for aging
- Area: Three-way valve (changeover valve) position and functionCheck: Daily: Check all valve positions; Monthly: Test three-way valve under simulated high-oil condition to confirm diversion to slop tank; Check for leakage at flange connections; Actuation without delay or abnormal noise
- Area: Process controller (EPC 60/70) alarms, data logging and sensor functionsCheck: Weekly: Check all sensors (temperature, pressure, speed) for functionality; Monthly: Check data logging device and review log data; Quarterly: Test all alarms and sensor outputs (document with protocol); Annually: Verify sensor calibration
- Area: Piping and flange connections: Leakage and corrosionCheck: Daily: Visually inspect all pipes and valve connections for oil film, droplet formation or corrosion (especially hot water/drain areas); Weekly: Check flanges for reduction in clamping force or leakage under load; Immediately repair if signs of corrosion or leakage appear
- Area: Heater (if electrical) and preheating to setpoint temperatureCheck: Daily: Check outlet temperature of preheated bilge water (typical: 50-70°C, manufacturer-specific); Weekly: Inspect heating element surface for deposits, wear or charring; Monthly: Calibrate thermostats and temperature sensors; If setpoint temperature is not reached, check thermocouple or controller
Type-universal inspection/maintenance points for oily water separator (Alfa Laval, Mega-Schwarm 2026-06). Per-model specs not auto-filled.
- Durchsatz (PureBilge 2515)
- 2.500 l/h
- Durchsatz (PureBilge 5015)
- 5.000 l/h
- Separator-drehzahl
- 8.000 rpm
- Ölgehalt Ausgabe (typisch)
- <5 ppm (MARPOL-Limit: 15 ppm)
- Filtermedium
- Vorwärmefilter + Koalescenteinsätze
- Prozessregler
- EPC 60/70 (computergestützt, mit Cybersecurity)
- PureBilge 2515 (2500 l/h, 15ppm)
- PureBilge 5015 (5000 l/h, 15ppm)
- PureBilge Compact 0605 (600 l/h, 5ppm)
- Area: 15ppm-Ölgehalt-Monitor (Optical Cell) Verschmutzung/KalibrierungCheck: Visual: Check optical cell for fouling; Function test via high-oil simulation (monthly); Calibration by authorized manufacturer agent every 12 months or before IOPP renewal survey (MEPC.107(49) § 4.2.11 requirement)
- Area: Coalescer inserts (filter/coalescer) blockage, wear or degradationCheck: Routine inspection: Weekly check filter/coalescer elements for wear, clogging or damage; Replace upon blockage or visible wear (planned maintenance). Internal inspection: Clear separator chamber and inspect coalescer inserts for aging
- Area: Three-way valve (changeover valve) position and functionCheck: Daily: Check all valve positions; Monthly: Test three-way valve under simulated high-oil condition to confirm diversion to slop tank; Check for leakage at flange connections; Actuation without delay or abnormal noise
- Area: Process controller (EPC 60/70) alarms, data logging and sensor functionsCheck: Weekly: Check all sensors (temperature, pressure, speed) for functionality; Monthly: Check data logging device and review log data; Quarterly: Test all alarms and sensor outputs (document with protocol); Annually: Verify sensor calibration
- Area: Piping and flange connections: Leakage and corrosionCheck: Daily: Visually inspect all pipes and valve connections for oil film, droplet formation or corrosion (especially hot water/drain areas); Weekly: Check flanges for reduction in clamping force or leakage under load; Immediately repair if signs of corrosion or leakage appear
- Area: Heater (if electrical) and preheating to setpoint temperatureCheck: Daily: Check outlet temperature of preheated bilge water (typical: 50-70°C, manufacturer-specific); Weekly: Inspect heating element surface for deposits, wear or charring; Monthly: Calibrate thermostats and temperature sensors; If setpoint temperature is not reached, check thermocouple or controller
Type-universal inspection/maintenance points for oily water separator (Alfa Laval, Mega-Schwarm 2026-06). Per-model specs not auto-filled.
- Durchsatz (PureBilge 2515)
- 2.500 l/h
- Durchsatz (PureBilge 5015)
- 5.000 l/h
- Separator-drehzahl
- 8.000 rpm
- Ölgehalt Ausgabe (typisch)
- <5 ppm (MARPOL-Limit: 15 ppm)
- Filtermedium
- Vorwärmefilter + Koalescenteinsätze
- Prozessregler
- EPC 60/70 (computergestützt, mit Cybersecurity)
- PureBilge 2515 (2500 l/h, 15ppm)
- PureBilge 5015 (5000 l/h, 15ppm)
- PureBilge Compact 0605 (600 l/h, 5ppm)
- Area: 15ppm-Ölgehalt-Monitor (Optical Cell) Verschmutzung/KalibrierungCheck: Visual: Check optical cell for fouling; Function test via high-oil simulation (monthly); Calibration by authorized manufacturer agent every 12 months or before IOPP renewal survey (MEPC.107(49) § 4.2.11 requirement)
- Area: Coalescer inserts (filter/coalescer) blockage, wear or degradationCheck: Routine inspection: Weekly check filter/coalescer elements for wear, clogging or damage; Replace upon blockage or visible wear (planned maintenance). Internal inspection: Clear separator chamber and inspect coalescer inserts for aging
- Area: Three-way valve (changeover valve) position and functionCheck: Daily: Check all valve positions; Monthly: Test three-way valve under simulated high-oil condition to confirm diversion to slop tank; Check for leakage at flange connections; Actuation without delay or abnormal noise
- Area: Process controller (EPC 60/70) alarms, data logging and sensor functionsCheck: Weekly: Check all sensors (temperature, pressure, speed) for functionality; Monthly: Check data logging device and review log data; Quarterly: Test all alarms and sensor outputs (document with protocol); Annually: Verify sensor calibration
- Area: Piping and flange connections: Leakage and corrosionCheck: Daily: Visually inspect all pipes and valve connections for oil film, droplet formation or corrosion (especially hot water/drain areas); Weekly: Check flanges for reduction in clamping force or leakage under load; Immediately repair if signs of corrosion or leakage appear
- Area: Heater (if electrical) and preheating to setpoint temperatureCheck: Daily: Check outlet temperature of preheated bilge water (typical: 50-70°C, manufacturer-specific); Weekly: Inspect heating element surface for deposits, wear or charring; Monthly: Calibrate thermostats and temperature sensors; If setpoint temperature is not reached, check thermocouple or controller
Type-universal inspection/maintenance points for oily water separator (Alfa Laval, Mega-Schwarm 2026-06). Per-model specs not auto-filled.
- Durchsatz (PureBilge 2515)
- 2.500 l/h
- Durchsatz (PureBilge 5015)
- 5.000 l/h
- Separator-drehzahl
- 8.000 rpm
- Ölgehalt Ausgabe (typisch)
- <5 ppm (MARPOL-Limit: 15 ppm)
- Filtermedium
- Vorwärmefilter + Koalescenteinsätze
- Prozessregler
- EPC 60/70 (computergestützt, mit Cybersecurity)
- PureBilge 2515 (2500 l/h, 15ppm)
- PureBilge 5015 (5000 l/h, 15ppm)
- PureBilge Compact 0605 (600 l/h, 5ppm)
- Area: 15ppm-Ölgehalt-Monitor (Optical Cell) Verschmutzung/KalibrierungCheck: Visual: Check optical cell for fouling; Function test via high-oil simulation (monthly); Calibration by authorized manufacturer agent every 12 months or before IOPP renewal survey (MEPC.107(49) § 4.2.11 requirement)
- Area: Coalescer inserts (filter/coalescer) blockage, wear or degradationCheck: Routine inspection: Weekly check filter/coalescer elements for wear, clogging or damage; Replace upon blockage or visible wear (planned maintenance). Internal inspection: Clear separator chamber and inspect coalescer inserts for aging
- Area: Three-way valve (changeover valve) position and functionCheck: Daily: Check all valve positions; Monthly: Test three-way valve under simulated high-oil condition to confirm diversion to slop tank; Check for leakage at flange connections; Actuation without delay or abnormal noise
- Area: Process controller (EPC 60/70) alarms, data logging and sensor functionsCheck: Weekly: Check all sensors (temperature, pressure, speed) for functionality; Monthly: Check data logging device and review log data; Quarterly: Test all alarms and sensor outputs (document with protocol); Annually: Verify sensor calibration
- Area: Piping and flange connections: Leakage and corrosionCheck: Daily: Visually inspect all pipes and valve connections for oil film, droplet formation or corrosion (especially hot water/drain areas); Weekly: Check flanges for reduction in clamping force or leakage under load; Immediately repair if signs of corrosion or leakage appear
- Area: Heater (if electrical) and preheating to setpoint temperatureCheck: Daily: Check outlet temperature of preheated bilge water (typical: 50-70°C, manufacturer-specific); Weekly: Inspect heating element surface for deposits, wear or charring; Monthly: Calibrate thermostats and temperature sensors; If setpoint temperature is not reached, check thermocouple or controller
Type-universal inspection/maintenance points for oily water separator (Alfa Laval, Mega-Schwarm 2026-06). Per-model specs not auto-filled.
- Durchsatz (PureBilge 2515)
- 2.500 l/h
- Durchsatz (PureBilge 5015)
- 5.000 l/h
- Separator-drehzahl
- 8.000 rpm
- Ölgehalt Ausgabe (typisch)
- <5 ppm (MARPOL-Limit: 15 ppm)
- Filtermedium
- Vorwärmefilter + Koalescenteinsätze
- Prozessregler
- EPC 60/70 (computergestützt, mit Cybersecurity)
- PureBilge 2515 (2500 l/h, 15ppm)
- PureBilge 5015 (5000 l/h, 15ppm)
- PureBilge Compact 0605 (600 l/h, 5ppm)
- Area: 15ppm-Ölgehalt-Monitor (Optical Cell) Verschmutzung/KalibrierungCheck: Visual: Check optical cell for fouling; Function test via high-oil simulation (monthly); Calibration by authorized manufacturer agent every 12 months or before IOPP renewal survey (MEPC.107(49) § 4.2.11 requirement)
- Area: Coalescer inserts (filter/coalescer) blockage, wear or degradationCheck: Routine inspection: Weekly check filter/coalescer elements for wear, clogging or damage; Replace upon blockage or visible wear (planned maintenance). Internal inspection: Clear separator chamber and inspect coalescer inserts for aging
- Area: Three-way valve (changeover valve) position and functionCheck: Daily: Check all valve positions; Monthly: Test three-way valve under simulated high-oil condition to confirm diversion to slop tank; Check for leakage at flange connections; Actuation without delay or abnormal noise
- Area: Process controller (EPC 60/70) alarms, data logging and sensor functionsCheck: Weekly: Check all sensors (temperature, pressure, speed) for functionality; Monthly: Check data logging device and review log data; Quarterly: Test all alarms and sensor outputs (document with protocol); Annually: Verify sensor calibration
- Area: Piping and flange connections: Leakage and corrosionCheck: Daily: Visually inspect all pipes and valve connections for oil film, droplet formation or corrosion (especially hot water/drain areas); Weekly: Check flanges for reduction in clamping force or leakage under load; Immediately repair if signs of corrosion or leakage appear
- Area: Heater (if electrical) and preheating to setpoint temperatureCheck: Daily: Check outlet temperature of preheated bilge water (typical: 50-70°C, manufacturer-specific); Weekly: Inspect heating element surface for deposits, wear or charring; Monthly: Calibrate thermostats and temperature sensors; If setpoint temperature is not reached, check thermocouple or controller
Type-universal inspection/maintenance points for oily water separator (Alfa Laval, Mega-Schwarm 2026-06). Per-model specs not auto-filled.
- Durchsatz (PureBilge 2515)
- 2.500 l/h
- Durchsatz (PureBilge 5015)
- 5.000 l/h
- Separator-drehzahl
- 8.000 rpm
- Ölgehalt Ausgabe (typisch)
- <5 ppm (MARPOL-Limit: 15 ppm)
- Filtermedium
- Vorwärmefilter + Koalescenteinsätze
- Prozessregler
- EPC 60/70 (computergestützt, mit Cybersecurity)
- PureBilge 2515 (2500 l/h, 15ppm)
- PureBilge 5015 (5000 l/h, 15ppm)
- PureBilge Compact 0605 (600 l/h, 5ppm)
- Area: 15ppm-Ölgehalt-Monitor (Optical Cell) Verschmutzung/KalibrierungCheck: Visual: Check optical cell for fouling; Function test via high-oil simulation (monthly); Calibration by authorized manufacturer agent every 12 months or before IOPP renewal survey (MEPC.107(49) § 4.2.11 requirement)
- Area: Coalescer inserts (filter/coalescer) blockage, wear or degradationCheck: Routine inspection: Weekly check filter/coalescer elements for wear, clogging or damage; Replace upon blockage or visible wear (planned maintenance). Internal inspection: Clear separator chamber and inspect coalescer inserts for aging
- Area: Three-way valve (changeover valve) position and functionCheck: Daily: Check all valve positions; Monthly: Test three-way valve under simulated high-oil condition to confirm diversion to slop tank; Check for leakage at flange connections; Actuation without delay or abnormal noise
- Area: Process controller (EPC 60/70) alarms, data logging and sensor functionsCheck: Weekly: Check all sensors (temperature, pressure, speed) for functionality; Monthly: Check data logging device and review log data; Quarterly: Test all alarms and sensor outputs (document with protocol); Annually: Verify sensor calibration
- Area: Piping and flange connections: Leakage and corrosionCheck: Daily: Visually inspect all pipes and valve connections for oil film, droplet formation or corrosion (especially hot water/drain areas); Weekly: Check flanges for reduction in clamping force or leakage under load; Immediately repair if signs of corrosion or leakage appear
- Area: Heater (if electrical) and preheating to setpoint temperatureCheck: Daily: Check outlet temperature of preheated bilge water (typical: 50-70°C, manufacturer-specific); Weekly: Inspect heating element surface for deposits, wear or charring; Monthly: Calibrate thermostats and temperature sensors; If setpoint temperature is not reached, check thermocouple or controller
Type-universal inspection/maintenance points for oily water separator (Alfa Laval, Mega-Schwarm 2026-06). Per-model specs not auto-filled.
- Durchsatz (PureBilge 2515)
- 2.500 l/h
- Durchsatz (PureBilge 5015)
- 5.000 l/h
- Separator-drehzahl
- 8.000 rpm
- Ölgehalt Ausgabe (typisch)
- <5 ppm (MARPOL-Limit: 15 ppm)
- Filtermedium
- Vorwärmefilter + Koalescenteinsätze
- Prozessregler
- EPC 60/70 (computergestützt, mit Cybersecurity)
- PureBilge 2515 (2500 l/h, 15ppm)
- PureBilge 5015 (5000 l/h, 15ppm)
- PureBilge Compact 0605 (600 l/h, 5ppm)
- Area: 15ppm-Ölgehalt-Monitor (Optical Cell) Verschmutzung/KalibrierungCheck: Visual: Check optical cell for fouling; Function test via high-oil simulation (monthly); Calibration by authorized manufacturer agent every 12 months or before IOPP renewal survey (MEPC.107(49) § 4.2.11 requirement)
- Area: Coalescer inserts (filter/coalescer) blockage, wear or degradationCheck: Routine inspection: Weekly check filter/coalescer elements for wear, clogging or damage; Replace upon blockage or visible wear (planned maintenance). Internal inspection: Clear separator chamber and inspect coalescer inserts for aging
- Area: Three-way valve (changeover valve) position and functionCheck: Daily: Check all valve positions; Monthly: Test three-way valve under simulated high-oil condition to confirm diversion to slop tank; Check for leakage at flange connections; Actuation without delay or abnormal noise
- Area: Process controller (EPC 60/70) alarms, data logging and sensor functionsCheck: Weekly: Check all sensors (temperature, pressure, speed) for functionality; Monthly: Check data logging device and review log data; Quarterly: Test all alarms and sensor outputs (document with protocol); Annually: Verify sensor calibration
- Area: Piping and flange connections: Leakage and corrosionCheck: Daily: Visually inspect all pipes and valve connections for oil film, droplet formation or corrosion (especially hot water/drain areas); Weekly: Check flanges for reduction in clamping force or leakage under load; Immediately repair if signs of corrosion or leakage appear
- Area: Heater (if electrical) and preheating to setpoint temperatureCheck: Daily: Check outlet temperature of preheated bilge water (typical: 50-70°C, manufacturer-specific); Weekly: Inspect heating element surface for deposits, wear or charring; Monthly: Calibrate thermostats and temperature sensors; If setpoint temperature is not reached, check thermocouple or controller
Type-universal inspection/maintenance points for oily water separator (Alfa Laval, Mega-Schwarm 2026-06). Per-model specs not auto-filled.
- Durchsatz (PureBilge 2515)
- 2.500 l/h
- Durchsatz (PureBilge 5015)
- 5.000 l/h
- Separator-drehzahl
- 8.000 rpm
- Ölgehalt Ausgabe (typisch)
- <5 ppm (MARPOL-Limit: 15 ppm)
- Filtermedium
- Vorwärmefilter + Koalescenteinsätze
- Prozessregler
- EPC 60/70 (computergestützt, mit Cybersecurity)
- PureBilge 2515 (2500 l/h, 15ppm)
- PureBilge 5015 (5000 l/h, 15ppm)
- PureBilge Compact 0605 (600 l/h, 5ppm)
- Area: 15ppm-Ölgehalt-Monitor (Optical Cell) Verschmutzung/KalibrierungCheck: Visual: Check optical cell for fouling; Function test via high-oil simulation (monthly); Calibration by authorized manufacturer agent every 12 months or before IOPP renewal survey (MEPC.107(49) § 4.2.11 requirement)
- Area: Coalescer inserts (filter/coalescer) blockage, wear or degradationCheck: Routine inspection: Weekly check filter/coalescer elements for wear, clogging or damage; Replace upon blockage or visible wear (planned maintenance). Internal inspection: Clear separator chamber and inspect coalescer inserts for aging
- Area: Three-way valve (changeover valve) position and functionCheck: Daily: Check all valve positions; Monthly: Test three-way valve under simulated high-oil condition to confirm diversion to slop tank; Check for leakage at flange connections; Actuation without delay or abnormal noise
- Area: Process controller (EPC 60/70) alarms, data logging and sensor functionsCheck: Weekly: Check all sensors (temperature, pressure, speed) for functionality; Monthly: Check data logging device and review log data; Quarterly: Test all alarms and sensor outputs (document with protocol); Annually: Verify sensor calibration
- Area: Piping and flange connections: Leakage and corrosionCheck: Daily: Visually inspect all pipes and valve connections for oil film, droplet formation or corrosion (especially hot water/drain areas); Weekly: Check flanges for reduction in clamping force or leakage under load; Immediately repair if signs of corrosion or leakage appear
- Area: Heater (if electrical) and preheating to setpoint temperatureCheck: Daily: Check outlet temperature of preheated bilge water (typical: 50-70°C, manufacturer-specific); Weekly: Inspect heating element surface for deposits, wear or charring; Monthly: Calibrate thermostats and temperature sensors; If setpoint temperature is not reached, check thermocouple or controller
Type-universal inspection/maintenance points for oily water separator (Alfa Laval, Mega-Schwarm 2026-06). Per-model specs not auto-filled.
- Durchsatz (PureBilge 2515)
- 2.500 l/h
- Durchsatz (PureBilge 5015)
- 5.000 l/h
- Separator-drehzahl
- 8.000 rpm
- Ölgehalt Ausgabe (typisch)
- <5 ppm (MARPOL-Limit: 15 ppm)
- Filtermedium
- Vorwärmefilter + Koalescenteinsätze
- Prozessregler
- EPC 60/70 (computergestützt, mit Cybersecurity)
- PureBilge 2515 (2500 l/h, 15ppm)
- PureBilge 5015 (5000 l/h, 15ppm)
- PureBilge Compact 0605 (600 l/h, 5ppm)
- Area: 15ppm-Ölgehalt-Monitor (Optical Cell) Verschmutzung/KalibrierungCheck: Visual: Check optical cell for fouling; Function test via high-oil simulation (monthly); Calibration by authorized manufacturer agent every 12 months or before IOPP renewal survey (MEPC.107(49) § 4.2.11 requirement)
- Area: Coalescer inserts (filter/coalescer) blockage, wear or degradationCheck: Routine inspection: Weekly check filter/coalescer elements for wear, clogging or damage; Replace upon blockage or visible wear (planned maintenance). Internal inspection: Clear separator chamber and inspect coalescer inserts for aging
- Area: Three-way valve (changeover valve) position and functionCheck: Daily: Check all valve positions; Monthly: Test three-way valve under simulated high-oil condition to confirm diversion to slop tank; Check for leakage at flange connections; Actuation without delay or abnormal noise
- Area: Process controller (EPC 60/70) alarms, data logging and sensor functionsCheck: Weekly: Check all sensors (temperature, pressure, speed) for functionality; Monthly: Check data logging device and review log data; Quarterly: Test all alarms and sensor outputs (document with protocol); Annually: Verify sensor calibration
- Area: Piping and flange connections: Leakage and corrosionCheck: Daily: Visually inspect all pipes and valve connections for oil film, droplet formation or corrosion (especially hot water/drain areas); Weekly: Check flanges for reduction in clamping force or leakage under load; Immediately repair if signs of corrosion or leakage appear
- Area: Heater (if electrical) and preheating to setpoint temperatureCheck: Daily: Check outlet temperature of preheated bilge water (typical: 50-70°C, manufacturer-specific); Weekly: Inspect heating element surface for deposits, wear or charring; Monthly: Calibrate thermostats and temperature sensors; If setpoint temperature is not reached, check thermocouple or controller
Type-universal inspection/maintenance points for oily water separator (Alfa Laval, Mega-Schwarm 2026-06). Per-model specs not auto-filled.
- Durchsatz (PureBilge 2515)
- 2.500 l/h
- Durchsatz (PureBilge 5015)
- 5.000 l/h
- Separator-drehzahl
- 8.000 rpm
- Ölgehalt Ausgabe (typisch)
- <5 ppm (MARPOL-Limit: 15 ppm)
- Filtermedium
- Vorwärmefilter + Koalescenteinsätze
- Prozessregler
- EPC 60/70 (computergestützt, mit Cybersecurity)
- PureBilge 2515 (2500 l/h, 15ppm)
- PureBilge 5015 (5000 l/h, 15ppm)
- PureBilge Compact 0605 (600 l/h, 5ppm)
- Area: 15ppm-Ölgehalt-Monitor (Optical Cell) Verschmutzung/KalibrierungCheck: Visual: Check optical cell for fouling; Function test via high-oil simulation (monthly); Calibration by authorized manufacturer agent every 12 months or before IOPP renewal survey (MEPC.107(49) § 4.2.11 requirement)
- Area: Coalescer inserts (filter/coalescer) blockage, wear or degradationCheck: Routine inspection: Weekly check filter/coalescer elements for wear, clogging or damage; Replace upon blockage or visible wear (planned maintenance). Internal inspection: Clear separator chamber and inspect coalescer inserts for aging
- Area: Three-way valve (changeover valve) position and functionCheck: Daily: Check all valve positions; Monthly: Test three-way valve under simulated high-oil condition to confirm diversion to slop tank; Check for leakage at flange connections; Actuation without delay or abnormal noise
- Area: Process controller (EPC 60/70) alarms, data logging and sensor functionsCheck: Weekly: Check all sensors (temperature, pressure, speed) for functionality; Monthly: Check data logging device and review log data; Quarterly: Test all alarms and sensor outputs (document with protocol); Annually: Verify sensor calibration
- Area: Piping and flange connections: Leakage and corrosionCheck: Daily: Visually inspect all pipes and valve connections for oil film, droplet formation or corrosion (especially hot water/drain areas); Weekly: Check flanges for reduction in clamping force or leakage under load; Immediately repair if signs of corrosion or leakage appear
- Area: Heater (if electrical) and preheating to setpoint temperatureCheck: Daily: Check outlet temperature of preheated bilge water (typical: 50-70°C, manufacturer-specific); Weekly: Inspect heating element surface for deposits, wear or charring; Monthly: Calibrate thermostats and temperature sensors; If setpoint temperature is not reached, check thermocouple or controller
Type-universal inspection/maintenance points for oily water separator (Alfa Laval, Mega-Schwarm 2026-06). Per-model specs not auto-filled.
- Durchsatz (PureBilge 2515)
- 2.500 l/h
- Durchsatz (PureBilge 5015)
- 5.000 l/h
- Separator-drehzahl
- 8.000 rpm
- Ölgehalt Ausgabe (typisch)
- <5 ppm (MARPOL-Limit: 15 ppm)
- Filtermedium
- Vorwärmefilter + Koalescenteinsätze
- Prozessregler
- EPC 60/70 (computergestützt, mit Cybersecurity)
- PureBilge 2515 (2500 l/h, 15ppm)
- PureBilge 5015 (5000 l/h, 15ppm)
- PureBilge Compact 0605 (600 l/h, 5ppm)
- Area: 15ppm-Ölgehalt-Monitor (Optical Cell) Verschmutzung/KalibrierungCheck: Visual: Check optical cell for fouling; Function test via high-oil simulation (monthly); Calibration by authorized manufacturer agent every 12 months or before IOPP renewal survey (MEPC.107(49) § 4.2.11 requirement)
- Area: Coalescer inserts (filter/coalescer) blockage, wear or degradationCheck: Routine inspection: Weekly check filter/coalescer elements for wear, clogging or damage; Replace upon blockage or visible wear (planned maintenance). Internal inspection: Clear separator chamber and inspect coalescer inserts for aging
- Area: Three-way valve (changeover valve) position and functionCheck: Daily: Check all valve positions; Monthly: Test three-way valve under simulated high-oil condition to confirm diversion to slop tank; Check for leakage at flange connections; Actuation without delay or abnormal noise
- Area: Process controller (EPC 60/70) alarms, data logging and sensor functionsCheck: Weekly: Check all sensors (temperature, pressure, speed) for functionality; Monthly: Check data logging device and review log data; Quarterly: Test all alarms and sensor outputs (document with protocol); Annually: Verify sensor calibration
- Area: Piping and flange connections: Leakage and corrosionCheck: Daily: Visually inspect all pipes and valve connections for oil film, droplet formation or corrosion (especially hot water/drain areas); Weekly: Check flanges for reduction in clamping force or leakage under load; Immediately repair if signs of corrosion or leakage appear
- Area: Heater (if electrical) and preheating to setpoint temperatureCheck: Daily: Check outlet temperature of preheated bilge water (typical: 50-70°C, manufacturer-specific); Weekly: Inspect heating element surface for deposits, wear or charring; Monthly: Calibrate thermostats and temperature sensors; If setpoint temperature is not reached, check thermocouple or controller
Type-universal inspection/maintenance points for oily water separator (Alfa Laval, Mega-Schwarm 2026-06). Per-model specs not auto-filled.
- Durchsatz (PureBilge 2515)
- 2.500 l/h
- Durchsatz (PureBilge 5015)
- 5.000 l/h
- Separator-drehzahl
- 8.000 rpm
- Ölgehalt Ausgabe (typisch)
- <5 ppm (MARPOL-Limit: 15 ppm)
- Filtermedium
- Vorwärmefilter + Koalescenteinsätze
- Prozessregler
- EPC 60/70 (computergestützt, mit Cybersecurity)
- PureBilge 2515 (2500 l/h, 15ppm)
- PureBilge 5015 (5000 l/h, 15ppm)
- PureBilge Compact 0605 (600 l/h, 5ppm)
- Area: 15ppm-Ölgehalt-Monitor (Optical Cell) Verschmutzung/KalibrierungCheck: Visual: Check optical cell for fouling; Function test via high-oil simulation (monthly); Calibration by authorized manufacturer agent every 12 months or before IOPP renewal survey (MEPC.107(49) § 4.2.11 requirement)
- Area: Coalescer inserts (filter/coalescer) blockage, wear or degradationCheck: Routine inspection: Weekly check filter/coalescer elements for wear, clogging or damage; Replace upon blockage or visible wear (planned maintenance). Internal inspection: Clear separator chamber and inspect coalescer inserts for aging
- Area: Three-way valve (changeover valve) position and functionCheck: Daily: Check all valve positions; Monthly: Test three-way valve under simulated high-oil condition to confirm diversion to slop tank; Check for leakage at flange connections; Actuation without delay or abnormal noise
- Area: Process controller (EPC 60/70) alarms, data logging and sensor functionsCheck: Weekly: Check all sensors (temperature, pressure, speed) for functionality; Monthly: Check data logging device and review log data; Quarterly: Test all alarms and sensor outputs (document with protocol); Annually: Verify sensor calibration
- Area: Piping and flange connections: Leakage and corrosionCheck: Daily: Visually inspect all pipes and valve connections for oil film, droplet formation or corrosion (especially hot water/drain areas); Weekly: Check flanges for reduction in clamping force or leakage under load; Immediately repair if signs of corrosion or leakage appear
- Area: Heater (if electrical) and preheating to setpoint temperatureCheck: Daily: Check outlet temperature of preheated bilge water (typical: 50-70°C, manufacturer-specific); Weekly: Inspect heating element surface for deposits, wear or charring; Monthly: Calibrate thermostats and temperature sensors; If setpoint temperature is not reached, check thermocouple or controller
Type-universal inspection/maintenance points for oily water separator (Alfa Laval, Mega-Schwarm 2026-06). Per-model specs not auto-filled.
- Durchsatz (PureBilge 2515)
- 2.500 l/h
- Durchsatz (PureBilge 5015)
- 5.000 l/h
- Separator-drehzahl
- 8.000 rpm
- Ölgehalt Ausgabe (typisch)
- <5 ppm (MARPOL-Limit: 15 ppm)
- Filtermedium
- Vorwärmefilter + Koalescenteinsätze
- Prozessregler
- EPC 60/70 (computergestützt, mit Cybersecurity)
- PureBilge 2515 (2500 l/h, 15ppm)
- PureBilge 5015 (5000 l/h, 15ppm)
- PureBilge Compact 0605 (600 l/h, 5ppm)
- Area: 15ppm-Ölgehalt-Monitor (Optical Cell) Verschmutzung/KalibrierungCheck: Visual: Check optical cell for fouling; Function test via high-oil simulation (monthly); Calibration by authorized manufacturer agent every 12 months or before IOPP renewal survey (MEPC.107(49) § 4.2.11 requirement)
- Area: Coalescer inserts (filter/coalescer) blockage, wear or degradationCheck: Routine inspection: Weekly check filter/coalescer elements for wear, clogging or damage; Replace upon blockage or visible wear (planned maintenance). Internal inspection: Clear separator chamber and inspect coalescer inserts for aging
- Area: Three-way valve (changeover valve) position and functionCheck: Daily: Check all valve positions; Monthly: Test three-way valve under simulated high-oil condition to confirm diversion to slop tank; Check for leakage at flange connections; Actuation without delay or abnormal noise
- Area: Process controller (EPC 60/70) alarms, data logging and sensor functionsCheck: Weekly: Check all sensors (temperature, pressure, speed) for functionality; Monthly: Check data logging device and review log data; Quarterly: Test all alarms and sensor outputs (document with protocol); Annually: Verify sensor calibration
- Area: Piping and flange connections: Leakage and corrosionCheck: Daily: Visually inspect all pipes and valve connections for oil film, droplet formation or corrosion (especially hot water/drain areas); Weekly: Check flanges for reduction in clamping force or leakage under load; Immediately repair if signs of corrosion or leakage appear
- Area: Heater (if electrical) and preheating to setpoint temperatureCheck: Daily: Check outlet temperature of preheated bilge water (typical: 50-70°C, manufacturer-specific); Weekly: Inspect heating element surface for deposits, wear or charring; Monthly: Calibrate thermostats and temperature sensors; If setpoint temperature is not reached, check thermocouple or controller
Type-universal inspection/maintenance points for oily water separator (Alfa Laval, Mega-Schwarm 2026-06). Per-model specs not auto-filled.
- Durchsatz (PureBilge 2515)
- 2.500 l/h
- Durchsatz (PureBilge 5015)
- 5.000 l/h
- Separator-drehzahl
- 8.000 rpm
- Ölgehalt Ausgabe (typisch)
- <5 ppm (MARPOL-Limit: 15 ppm)
- Filtermedium
- Vorwärmefilter + Koalescenteinsätze
- Prozessregler
- EPC 60/70 (computergestützt, mit Cybersecurity)
- PureBilge 2515 (2500 l/h, 15ppm)
- PureBilge 5015 (5000 l/h, 15ppm)
- PureBilge Compact 0605 (600 l/h, 5ppm)
- Area: 15ppm-Ölgehalt-Monitor (Optical Cell) Verschmutzung/KalibrierungCheck: Visual: Check optical cell for fouling; Function test via high-oil simulation (monthly); Calibration by authorized manufacturer agent every 12 months or before IOPP renewal survey (MEPC.107(49) § 4.2.11 requirement)
- Area: Coalescer inserts (filter/coalescer) blockage, wear or degradationCheck: Routine inspection: Weekly check filter/coalescer elements for wear, clogging or damage; Replace upon blockage or visible wear (planned maintenance). Internal inspection: Clear separator chamber and inspect coalescer inserts for aging
- Area: Three-way valve (changeover valve) position and functionCheck: Daily: Check all valve positions; Monthly: Test three-way valve under simulated high-oil condition to confirm diversion to slop tank; Check for leakage at flange connections; Actuation without delay or abnormal noise
- Area: Process controller (EPC 60/70) alarms, data logging and sensor functionsCheck: Weekly: Check all sensors (temperature, pressure, speed) for functionality; Monthly: Check data logging device and review log data; Quarterly: Test all alarms and sensor outputs (document with protocol); Annually: Verify sensor calibration
- Area: Piping and flange connections: Leakage and corrosionCheck: Daily: Visually inspect all pipes and valve connections for oil film, droplet formation or corrosion (especially hot water/drain areas); Weekly: Check flanges for reduction in clamping force or leakage under load; Immediately repair if signs of corrosion or leakage appear
- Area: Heater (if electrical) and preheating to setpoint temperatureCheck: Daily: Check outlet temperature of preheated bilge water (typical: 50-70°C, manufacturer-specific); Weekly: Inspect heating element surface for deposits, wear or charring; Monthly: Calibrate thermostats and temperature sensors; If setpoint temperature is not reached, check thermocouple or controller
Type-universal inspection/maintenance points for oily water separator (Alfa Laval, Mega-Schwarm 2026-06). Per-model specs not auto-filled.
- Durchsatz (PureBilge 2515)
- 2.500 l/h
- Durchsatz (PureBilge 5015)
- 5.000 l/h
- Separator-drehzahl
- 8.000 rpm
- Ölgehalt Ausgabe (typisch)
- <5 ppm (MARPOL-Limit: 15 ppm)
- Filtermedium
- Vorwärmefilter + Koalescenteinsätze
- Prozessregler
- EPC 60/70 (computergestützt, mit Cybersecurity)
- PureBilge 2515 (2500 l/h, 15ppm)
- PureBilge 5015 (5000 l/h, 15ppm)
- PureBilge Compact 0605 (600 l/h, 5ppm)
- Area: 15ppm-Ölgehalt-Monitor (Optical Cell) Verschmutzung/KalibrierungCheck: Visual: Check optical cell for fouling; Function test via high-oil simulation (monthly); Calibration by authorized manufacturer agent every 12 months or before IOPP renewal survey (MEPC.107(49) § 4.2.11 requirement)
- Area: Coalescer inserts (filter/coalescer) blockage, wear or degradationCheck: Routine inspection: Weekly check filter/coalescer elements for wear, clogging or damage; Replace upon blockage or visible wear (planned maintenance). Internal inspection: Clear separator chamber and inspect coalescer inserts for aging
- Area: Three-way valve (changeover valve) position and functionCheck: Daily: Check all valve positions; Monthly: Test three-way valve under simulated high-oil condition to confirm diversion to slop tank; Check for leakage at flange connections; Actuation without delay or abnormal noise
- Area: Process controller (EPC 60/70) alarms, data logging and sensor functionsCheck: Weekly: Check all sensors (temperature, pressure, speed) for functionality; Monthly: Check data logging device and review log data; Quarterly: Test all alarms and sensor outputs (document with protocol); Annually: Verify sensor calibration
- Area: Piping and flange connections: Leakage and corrosionCheck: Daily: Visually inspect all pipes and valve connections for oil film, droplet formation or corrosion (especially hot water/drain areas); Weekly: Check flanges for reduction in clamping force or leakage under load; Immediately repair if signs of corrosion or leakage appear
- Area: Heater (if electrical) and preheating to setpoint temperatureCheck: Daily: Check outlet temperature of preheated bilge water (typical: 50-70°C, manufacturer-specific); Weekly: Inspect heating element surface for deposits, wear or charring; Monthly: Calibrate thermostats and temperature sensors; If setpoint temperature is not reached, check thermocouple or controller
Type-universal inspection/maintenance points for oily water separator (Alfa Laval, Mega-Schwarm 2026-06). Per-model specs not auto-filled.
- Durchsatz (PureBilge 2515)
- 2.500 l/h
- Durchsatz (PureBilge 5015)
- 5.000 l/h
- Separator-drehzahl
- 8.000 rpm
- Ölgehalt Ausgabe (typisch)
- <5 ppm (MARPOL-Limit: 15 ppm)
- Filtermedium
- Vorwärmefilter + Koalescenteinsätze
- Prozessregler
- EPC 60/70 (computergestützt, mit Cybersecurity)
- PureBilge 2515 (2500 l/h, 15ppm)
- PureBilge 5015 (5000 l/h, 15ppm)
- PureBilge Compact 0605 (600 l/h, 5ppm)
- Area: 15ppm-Ölgehalt-Monitor (Optical Cell) Verschmutzung/KalibrierungCheck: Visual: Check optical cell for fouling; Function test via high-oil simulation (monthly); Calibration by authorized manufacturer agent every 12 months or before IOPP renewal survey (MEPC.107(49) § 4.2.11 requirement)
- Area: Coalescer inserts (filter/coalescer) blockage, wear or degradationCheck: Routine inspection: Weekly check filter/coalescer elements for wear, clogging or damage; Replace upon blockage or visible wear (planned maintenance). Internal inspection: Clear separator chamber and inspect coalescer inserts for aging
- Area: Three-way valve (changeover valve) position and functionCheck: Daily: Check all valve positions; Monthly: Test three-way valve under simulated high-oil condition to confirm diversion to slop tank; Check for leakage at flange connections; Actuation without delay or abnormal noise
- Area: Process controller (EPC 60/70) alarms, data logging and sensor functionsCheck: Weekly: Check all sensors (temperature, pressure, speed) for functionality; Monthly: Check data logging device and review log data; Quarterly: Test all alarms and sensor outputs (document with protocol); Annually: Verify sensor calibration
- Area: Piping and flange connections: Leakage and corrosionCheck: Daily: Visually inspect all pipes and valve connections for oil film, droplet formation or corrosion (especially hot water/drain areas); Weekly: Check flanges for reduction in clamping force or leakage under load; Immediately repair if signs of corrosion or leakage appear
- Area: Heater (if electrical) and preheating to setpoint temperatureCheck: Daily: Check outlet temperature of preheated bilge water (typical: 50-70°C, manufacturer-specific); Weekly: Inspect heating element surface for deposits, wear or charring; Monthly: Calibrate thermostats and temperature sensors; If setpoint temperature is not reached, check thermocouple or controller
Type-universal inspection/maintenance points for oily water separator (Alfa Laval, Mega-Schwarm 2026-06). Per-model specs not auto-filled.
- Durchsatz (PureBilge 2515)
- 2.500 l/h
- Durchsatz (PureBilge 5015)
- 5.000 l/h
- Separator-drehzahl
- 8.000 rpm
- Ölgehalt Ausgabe (typisch)
- <5 ppm (MARPOL-Limit: 15 ppm)
- Filtermedium
- Vorwärmefilter + Koalescenteinsätze
- Prozessregler
- EPC 60/70 (computergestützt, mit Cybersecurity)
- PureBilge 2515 (2500 l/h, 15ppm)
- PureBilge 5015 (5000 l/h, 15ppm)
- PureBilge Compact 0605 (600 l/h, 5ppm)
- Area: 15ppm-Ölgehalt-Monitor (Optical Cell) Verschmutzung/KalibrierungCheck: Visual: Check optical cell for fouling; Function test via high-oil simulation (monthly); Calibration by authorized manufacturer agent every 12 months or before IOPP renewal survey (MEPC.107(49) § 4.2.11 requirement)
- Area: Coalescer inserts (filter/coalescer) blockage, wear or degradationCheck: Routine inspection: Weekly check filter/coalescer elements for wear, clogging or damage; Replace upon blockage or visible wear (planned maintenance). Internal inspection: Clear separator chamber and inspect coalescer inserts for aging
- Area: Three-way valve (changeover valve) position and functionCheck: Daily: Check all valve positions; Monthly: Test three-way valve under simulated high-oil condition to confirm diversion to slop tank; Check for leakage at flange connections; Actuation without delay or abnormal noise
- Area: Process controller (EPC 60/70) alarms, data logging and sensor functionsCheck: Weekly: Check all sensors (temperature, pressure, speed) for functionality; Monthly: Check data logging device and review log data; Quarterly: Test all alarms and sensor outputs (document with protocol); Annually: Verify sensor calibration
- Area: Piping and flange connections: Leakage and corrosionCheck: Daily: Visually inspect all pipes and valve connections for oil film, droplet formation or corrosion (especially hot water/drain areas); Weekly: Check flanges for reduction in clamping force or leakage under load; Immediately repair if signs of corrosion or leakage appear
- Area: Heater (if electrical) and preheating to setpoint temperatureCheck: Daily: Check outlet temperature of preheated bilge water (typical: 50-70°C, manufacturer-specific); Weekly: Inspect heating element surface for deposits, wear or charring; Monthly: Calibrate thermostats and temperature sensors; If setpoint temperature is not reached, check thermocouple or controller
Type-universal inspection/maintenance points for oily water separator (Alfa Laval, Mega-Schwarm 2026-06). Per-model specs not auto-filled.
- Durchsatz (PureBilge 2515)
- 2.500 l/h
- Durchsatz (PureBilge 5015)
- 5.000 l/h
- Separator-drehzahl
- 8.000 rpm
- Ölgehalt Ausgabe (typisch)
- <5 ppm (MARPOL-Limit: 15 ppm)
- Filtermedium
- Vorwärmefilter + Koalescenteinsätze
- Prozessregler
- EPC 60/70 (computergestützt, mit Cybersecurity)
- PureBilge 2515 (2500 l/h, 15ppm)
- PureBilge 5015 (5000 l/h, 15ppm)
- PureBilge Compact 0605 (600 l/h, 5ppm)
- Area: 15ppm-Ölgehalt-Monitor (Optical Cell) Verschmutzung/KalibrierungCheck: Visual: Check optical cell for fouling; Function test via high-oil simulation (monthly); Calibration by authorized manufacturer agent every 12 months or before IOPP renewal survey (MEPC.107(49) § 4.2.11 requirement)
- Area: Coalescer inserts (filter/coalescer) blockage, wear or degradationCheck: Routine inspection: Weekly check filter/coalescer elements for wear, clogging or damage; Replace upon blockage or visible wear (planned maintenance). Internal inspection: Clear separator chamber and inspect coalescer inserts for aging
- Area: Three-way valve (changeover valve) position and functionCheck: Daily: Check all valve positions; Monthly: Test three-way valve under simulated high-oil condition to confirm diversion to slop tank; Check for leakage at flange connections; Actuation without delay or abnormal noise
- Area: Process controller (EPC 60/70) alarms, data logging and sensor functionsCheck: Weekly: Check all sensors (temperature, pressure, speed) for functionality; Monthly: Check data logging device and review log data; Quarterly: Test all alarms and sensor outputs (document with protocol); Annually: Verify sensor calibration
- Area: Piping and flange connections: Leakage and corrosionCheck: Daily: Visually inspect all pipes and valve connections for oil film, droplet formation or corrosion (especially hot water/drain areas); Weekly: Check flanges for reduction in clamping force or leakage under load; Immediately repair if signs of corrosion or leakage appear
- Area: Heater (if electrical) and preheating to setpoint temperatureCheck: Daily: Check outlet temperature of preheated bilge water (typical: 50-70°C, manufacturer-specific); Weekly: Inspect heating element surface for deposits, wear or charring; Monthly: Calibrate thermostats and temperature sensors; If setpoint temperature is not reached, check thermocouple or controller
Type-universal inspection/maintenance points for oily water separator (Alfa Laval, Mega-Schwarm 2026-06). Per-model specs not auto-filled.
- Durchsatz (PureBilge 2515)
- 2.500 l/h
- Durchsatz (PureBilge 5015)
- 5.000 l/h
- Separator-drehzahl
- 8.000 rpm
- Ölgehalt Ausgabe (typisch)
- <5 ppm (MARPOL-Limit: 15 ppm)
- Filtermedium
- Vorwärmefilter + Koalescenteinsätze
- Prozessregler
- EPC 60/70 (computergestützt, mit Cybersecurity)
- PureBilge 2515 (2500 l/h, 15ppm)
- PureBilge 5015 (5000 l/h, 15ppm)
- PureBilge Compact 0605 (600 l/h, 5ppm)
- Area: 15ppm-Ölgehalt-Monitor (Optical Cell) Verschmutzung/KalibrierungCheck: Visual: Check optical cell for fouling; Function test via high-oil simulation (monthly); Calibration by authorized manufacturer agent every 12 months or before IOPP renewal survey (MEPC.107(49) § 4.2.11 requirement)
- Area: Coalescer inserts (filter/coalescer) blockage, wear or degradationCheck: Routine inspection: Weekly check filter/coalescer elements for wear, clogging or damage; Replace upon blockage or visible wear (planned maintenance). Internal inspection: Clear separator chamber and inspect coalescer inserts for aging
- Area: Three-way valve (changeover valve) position and functionCheck: Daily: Check all valve positions; Monthly: Test three-way valve under simulated high-oil condition to confirm diversion to slop tank; Check for leakage at flange connections; Actuation without delay or abnormal noise
- Area: Process controller (EPC 60/70) alarms, data logging and sensor functionsCheck: Weekly: Check all sensors (temperature, pressure, speed) for functionality; Monthly: Check data logging device and review log data; Quarterly: Test all alarms and sensor outputs (document with protocol); Annually: Verify sensor calibration
- Area: Piping and flange connections: Leakage and corrosionCheck: Daily: Visually inspect all pipes and valve connections for oil film, droplet formation or corrosion (especially hot water/drain areas); Weekly: Check flanges for reduction in clamping force or leakage under load; Immediately repair if signs of corrosion or leakage appear
- Area: Heater (if electrical) and preheating to setpoint temperatureCheck: Daily: Check outlet temperature of preheated bilge water (typical: 50-70°C, manufacturer-specific); Weekly: Inspect heating element surface for deposits, wear or charring; Monthly: Calibrate thermostats and temperature sensors; If setpoint temperature is not reached, check thermocouple or controller
Type-universal inspection/maintenance points for oily water separator (Alfa Laval, Mega-Schwarm 2026-06). Per-model specs not auto-filled.
- Durchsatz (PureBilge 2515)
- 2.500 l/h
- Durchsatz (PureBilge 5015)
- 5.000 l/h
- Separator-drehzahl
- 8.000 rpm
- Ölgehalt Ausgabe (typisch)
- <5 ppm (MARPOL-Limit: 15 ppm)
- Filtermedium
- Vorwärmefilter + Koalescenteinsätze
- Prozessregler
- EPC 60/70 (computergestützt, mit Cybersecurity)
- PureBilge 2515 (2500 l/h, 15ppm)
- PureBilge 5015 (5000 l/h, 15ppm)
- PureBilge Compact 0605 (600 l/h, 5ppm)
- Area: 15ppm-Ölgehalt-Monitor (Optical Cell) Verschmutzung/KalibrierungCheck: Visual: Check optical cell for fouling; Function test via high-oil simulation (monthly); Calibration by authorized manufacturer agent every 12 months or before IOPP renewal survey (MEPC.107(49) § 4.2.11 requirement)
- Area: Coalescer inserts (filter/coalescer) blockage, wear or degradationCheck: Routine inspection: Weekly check filter/coalescer elements for wear, clogging or damage; Replace upon blockage or visible wear (planned maintenance). Internal inspection: Clear separator chamber and inspect coalescer inserts for aging
- Area: Three-way valve (changeover valve) position and functionCheck: Daily: Check all valve positions; Monthly: Test three-way valve under simulated high-oil condition to confirm diversion to slop tank; Check for leakage at flange connections; Actuation without delay or abnormal noise
- Area: Process controller (EPC 60/70) alarms, data logging and sensor functionsCheck: Weekly: Check all sensors (temperature, pressure, speed) for functionality; Monthly: Check data logging device and review log data; Quarterly: Test all alarms and sensor outputs (document with protocol); Annually: Verify sensor calibration
- Area: Piping and flange connections: Leakage and corrosionCheck: Daily: Visually inspect all pipes and valve connections for oil film, droplet formation or corrosion (especially hot water/drain areas); Weekly: Check flanges for reduction in clamping force or leakage under load; Immediately repair if signs of corrosion or leakage appear
- Area: Heater (if electrical) and preheating to setpoint temperatureCheck: Daily: Check outlet temperature of preheated bilge water (typical: 50-70°C, manufacturer-specific); Weekly: Inspect heating element surface for deposits, wear or charring; Monthly: Calibrate thermostats and temperature sensors; If setpoint temperature is not reached, check thermocouple or controller
Type-universal inspection/maintenance points for oily water separator (Alfa Laval, Mega-Schwarm 2026-06). Per-model specs not auto-filled.
- Durchsatz (PureBilge 2515)
- 2.500 l/h
- Durchsatz (PureBilge 5015)
- 5.000 l/h
- Separator-drehzahl
- 8.000 rpm
- Ölgehalt Ausgabe (typisch)
- <5 ppm (MARPOL-Limit: 15 ppm)
- Filtermedium
- Vorwärmefilter + Koalescenteinsätze
- Prozessregler
- EPC 60/70 (computergestützt, mit Cybersecurity)
- PureBilge 2515 (2500 l/h, 15ppm)
- PureBilge 5015 (5000 l/h, 15ppm)
- PureBilge Compact 0605 (600 l/h, 5ppm)
- Area: 15ppm-Ölgehalt-Monitor (Optical Cell) Verschmutzung/KalibrierungCheck: Visual: Check optical cell for fouling; Function test via high-oil simulation (monthly); Calibration by authorized manufacturer agent every 12 months or before IOPP renewal survey (MEPC.107(49) § 4.2.11 requirement)
- Area: Coalescer inserts (filter/coalescer) blockage, wear or degradationCheck: Routine inspection: Weekly check filter/coalescer elements for wear, clogging or damage; Replace upon blockage or visible wear (planned maintenance). Internal inspection: Clear separator chamber and inspect coalescer inserts for aging
- Area: Three-way valve (changeover valve) position and functionCheck: Daily: Check all valve positions; Monthly: Test three-way valve under simulated high-oil condition to confirm diversion to slop tank; Check for leakage at flange connections; Actuation without delay or abnormal noise
- Area: Process controller (EPC 60/70) alarms, data logging and sensor functionsCheck: Weekly: Check all sensors (temperature, pressure, speed) for functionality; Monthly: Check data logging device and review log data; Quarterly: Test all alarms and sensor outputs (document with protocol); Annually: Verify sensor calibration
- Area: Piping and flange connections: Leakage and corrosionCheck: Daily: Visually inspect all pipes and valve connections for oil film, droplet formation or corrosion (especially hot water/drain areas); Weekly: Check flanges for reduction in clamping force or leakage under load; Immediately repair if signs of corrosion or leakage appear
- Area: Heater (if electrical) and preheating to setpoint temperatureCheck: Daily: Check outlet temperature of preheated bilge water (typical: 50-70°C, manufacturer-specific); Weekly: Inspect heating element surface for deposits, wear or charring; Monthly: Calibrate thermostats and temperature sensors; If setpoint temperature is not reached, check thermocouple or controller
Type-universal inspection/maintenance points for oily water separator (Alfa Laval, Mega-Schwarm 2026-06). Per-model specs not auto-filled.
- Durchsatz (PureBilge 2515)
- 2.500 l/h
- Durchsatz (PureBilge 5015)
- 5.000 l/h
- Separator-drehzahl
- 8.000 rpm
- Ölgehalt Ausgabe (typisch)
- <5 ppm (MARPOL-Limit: 15 ppm)
- Filtermedium
- Vorwärmefilter + Koalescenteinsätze
- Prozessregler
- EPC 60/70 (computergestützt, mit Cybersecurity)
- PureBilge 2515 (2500 l/h, 15ppm)
- PureBilge 5015 (5000 l/h, 15ppm)
- PureBilge Compact 0605 (600 l/h, 5ppm)
- Area: 15ppm-Ölgehalt-Monitor (Optical Cell) Verschmutzung/KalibrierungCheck: Visual: Check optical cell for fouling; Function test via high-oil simulation (monthly); Calibration by authorized manufacturer agent every 12 months or before IOPP renewal survey (MEPC.107(49) § 4.2.11 requirement)
- Area: Coalescer inserts (filter/coalescer) blockage, wear or degradationCheck: Routine inspection: Weekly check filter/coalescer elements for wear, clogging or damage; Replace upon blockage or visible wear (planned maintenance). Internal inspection: Clear separator chamber and inspect coalescer inserts for aging
- Area: Three-way valve (changeover valve) position and functionCheck: Daily: Check all valve positions; Monthly: Test three-way valve under simulated high-oil condition to confirm diversion to slop tank; Check for leakage at flange connections; Actuation without delay or abnormal noise
- Area: Process controller (EPC 60/70) alarms, data logging and sensor functionsCheck: Weekly: Check all sensors (temperature, pressure, speed) for functionality; Monthly: Check data logging device and review log data; Quarterly: Test all alarms and sensor outputs (document with protocol); Annually: Verify sensor calibration
- Area: Piping and flange connections: Leakage and corrosionCheck: Daily: Visually inspect all pipes and valve connections for oil film, droplet formation or corrosion (especially hot water/drain areas); Weekly: Check flanges for reduction in clamping force or leakage under load; Immediately repair if signs of corrosion or leakage appear
- Area: Heater (if electrical) and preheating to setpoint temperatureCheck: Daily: Check outlet temperature of preheated bilge water (typical: 50-70°C, manufacturer-specific); Weekly: Inspect heating element surface for deposits, wear or charring; Monthly: Calibrate thermostats and temperature sensors; If setpoint temperature is not reached, check thermocouple or controller
Type-universal inspection/maintenance points for oily water separator (Alfa Laval, Mega-Schwarm 2026-06). Per-model specs not auto-filled.
- Durchsatz (PureBilge 2515)
- 2.500 l/h
- Durchsatz (PureBilge 5015)
- 5.000 l/h
- Separator-drehzahl
- 8.000 rpm
- Ölgehalt Ausgabe (typisch)
- <5 ppm (MARPOL-Limit: 15 ppm)
- Filtermedium
- Vorwärmefilter + Koalescenteinsätze
- Prozessregler
- EPC 60/70 (computergestützt, mit Cybersecurity)
- PureBilge 2515 (2500 l/h, 15ppm)
- PureBilge 5015 (5000 l/h, 15ppm)
- PureBilge Compact 0605 (600 l/h, 5ppm)
- Area: 15ppm-Ölgehalt-Monitor (Optical Cell) Verschmutzung/KalibrierungCheck: Visual: Check optical cell for fouling; Function test via high-oil simulation (monthly); Calibration by authorized manufacturer agent every 12 months or before IOPP renewal survey (MEPC.107(49) § 4.2.11 requirement)
- Area: Coalescer inserts (filter/coalescer) blockage, wear or degradationCheck: Routine inspection: Weekly check filter/coalescer elements for wear, clogging or damage; Replace upon blockage or visible wear (planned maintenance). Internal inspection: Clear separator chamber and inspect coalescer inserts for aging
- Area: Three-way valve (changeover valve) position and functionCheck: Daily: Check all valve positions; Monthly: Test three-way valve under simulated high-oil condition to confirm diversion to slop tank; Check for leakage at flange connections; Actuation without delay or abnormal noise
- Area: Process controller (EPC 60/70) alarms, data logging and sensor functionsCheck: Weekly: Check all sensors (temperature, pressure, speed) for functionality; Monthly: Check data logging device and review log data; Quarterly: Test all alarms and sensor outputs (document with protocol); Annually: Verify sensor calibration
- Area: Piping and flange connections: Leakage and corrosionCheck: Daily: Visually inspect all pipes and valve connections for oil film, droplet formation or corrosion (especially hot water/drain areas); Weekly: Check flanges for reduction in clamping force or leakage under load; Immediately repair if signs of corrosion or leakage appear
- Area: Heater (if electrical) and preheating to setpoint temperatureCheck: Daily: Check outlet temperature of preheated bilge water (typical: 50-70°C, manufacturer-specific); Weekly: Inspect heating element surface for deposits, wear or charring; Monthly: Calibrate thermostats and temperature sensors; If setpoint temperature is not reached, check thermocouple or controller
Type-universal inspection/maintenance points for oily water separator (Alfa Laval, Mega-Schwarm 2026-06). Per-model specs not auto-filled.
- Durchsatz (PureBilge 2515)
- 2.500 l/h
- Durchsatz (PureBilge 5015)
- 5.000 l/h
- Separator-drehzahl
- 8.000 rpm
- Ölgehalt Ausgabe (typisch)
- <5 ppm (MARPOL-Limit: 15 ppm)
- Filtermedium
- Vorwärmefilter + Koalescenteinsätze
- Prozessregler
- EPC 60/70 (computergestützt, mit Cybersecurity)
- PureBilge 2515 (2500 l/h, 15ppm)
- PureBilge 5015 (5000 l/h, 15ppm)
- PureBilge Compact 0605 (600 l/h, 5ppm)
- Area: 15ppm-Ölgehalt-Monitor (Optical Cell) Verschmutzung/KalibrierungCheck: Visual: Check optical cell for fouling; Function test via high-oil simulation (monthly); Calibration by authorized manufacturer agent every 12 months or before IOPP renewal survey (MEPC.107(49) § 4.2.11 requirement)
- Area: Coalescer inserts (filter/coalescer) blockage, wear or degradationCheck: Routine inspection: Weekly check filter/coalescer elements for wear, clogging or damage; Replace upon blockage or visible wear (planned maintenance). Internal inspection: Clear separator chamber and inspect coalescer inserts for aging
- Area: Three-way valve (changeover valve) position and functionCheck: Daily: Check all valve positions; Monthly: Test three-way valve under simulated high-oil condition to confirm diversion to slop tank; Check for leakage at flange connections; Actuation without delay or abnormal noise
- Area: Process controller (EPC 60/70) alarms, data logging and sensor functionsCheck: Weekly: Check all sensors (temperature, pressure, speed) for functionality; Monthly: Check data logging device and review log data; Quarterly: Test all alarms and sensor outputs (document with protocol); Annually: Verify sensor calibration
- Area: Piping and flange connections: Leakage and corrosionCheck: Daily: Visually inspect all pipes and valve connections for oil film, droplet formation or corrosion (especially hot water/drain areas); Weekly: Check flanges for reduction in clamping force or leakage under load; Immediately repair if signs of corrosion or leakage appear
- Area: Heater (if electrical) and preheating to setpoint temperatureCheck: Daily: Check outlet temperature of preheated bilge water (typical: 50-70°C, manufacturer-specific); Weekly: Inspect heating element surface for deposits, wear or charring; Monthly: Calibrate thermostats and temperature sensors; If setpoint temperature is not reached, check thermocouple or controller
Type-universal inspection/maintenance points for oily water separator (Alfa Laval, Mega-Schwarm 2026-06). Per-model specs not auto-filled.
- Durchsatz (PureBilge 2515)
- 2.500 l/h
- Durchsatz (PureBilge 5015)
- 5.000 l/h
- Separator-drehzahl
- 8.000 rpm
- Ölgehalt Ausgabe (typisch)
- <5 ppm (MARPOL-Limit: 15 ppm)
- Filtermedium
- Vorwärmefilter + Koalescenteinsätze
- Prozessregler
- EPC 60/70 (computergestützt, mit Cybersecurity)
- PureBilge 2515 (2500 l/h, 15ppm)
- PureBilge 5015 (5000 l/h, 15ppm)
- PureBilge Compact 0605 (600 l/h, 5ppm)
- Area: 15ppm-Ölgehalt-Monitor (Optical Cell) Verschmutzung/KalibrierungCheck: Visual: Check optical cell for fouling; Function test via high-oil simulation (monthly); Calibration by authorized manufacturer agent every 12 months or before IOPP renewal survey (MEPC.107(49) § 4.2.11 requirement)
- Area: Coalescer inserts (filter/coalescer) blockage, wear or degradationCheck: Routine inspection: Weekly check filter/coalescer elements for wear, clogging or damage; Replace upon blockage or visible wear (planned maintenance). Internal inspection: Clear separator chamber and inspect coalescer inserts for aging
- Area: Three-way valve (changeover valve) position and functionCheck: Daily: Check all valve positions; Monthly: Test three-way valve under simulated high-oil condition to confirm diversion to slop tank; Check for leakage at flange connections; Actuation without delay or abnormal noise
- Area: Process controller (EPC 60/70) alarms, data logging and sensor functionsCheck: Weekly: Check all sensors (temperature, pressure, speed) for functionality; Monthly: Check data logging device and review log data; Quarterly: Test all alarms and sensor outputs (document with protocol); Annually: Verify sensor calibration
- Area: Piping and flange connections: Leakage and corrosionCheck: Daily: Visually inspect all pipes and valve connections for oil film, droplet formation or corrosion (especially hot water/drain areas); Weekly: Check flanges for reduction in clamping force or leakage under load; Immediately repair if signs of corrosion or leakage appear
- Area: Heater (if electrical) and preheating to setpoint temperatureCheck: Daily: Check outlet temperature of preheated bilge water (typical: 50-70°C, manufacturer-specific); Weekly: Inspect heating element surface for deposits, wear or charring; Monthly: Calibrate thermostats and temperature sensors; If setpoint temperature is not reached, check thermocouple or controller
Type-universal inspection/maintenance points for oily water separator (Alfa Laval, Mega-Schwarm 2026-06). Per-model specs not auto-filled.
- Durchsatz (PureBilge 2515)
- 2.500 l/h
- Durchsatz (PureBilge 5015)
- 5.000 l/h
- Separator-drehzahl
- 8.000 rpm
- Ölgehalt Ausgabe (typisch)
- <5 ppm (MARPOL-Limit: 15 ppm)
- Filtermedium
- Vorwärmefilter + Koalescenteinsätze
- Prozessregler
- EPC 60/70 (computergestützt, mit Cybersecurity)
- PureBilge 2515 (2500 l/h, 15ppm)
- PureBilge 5015 (5000 l/h, 15ppm)
- PureBilge Compact 0605 (600 l/h, 5ppm)
- Area: 15ppm-Ölgehalt-Monitor (Optical Cell) Verschmutzung/KalibrierungCheck: Visual: Check optical cell for fouling; Function test via high-oil simulation (monthly); Calibration by authorized manufacturer agent every 12 months or before IOPP renewal survey (MEPC.107(49) § 4.2.11 requirement)
- Area: Coalescer inserts (filter/coalescer) blockage, wear or degradationCheck: Routine inspection: Weekly check filter/coalescer elements for wear, clogging or damage; Replace upon blockage or visible wear (planned maintenance). Internal inspection: Clear separator chamber and inspect coalescer inserts for aging
- Area: Three-way valve (changeover valve) position and functionCheck: Daily: Check all valve positions; Monthly: Test three-way valve under simulated high-oil condition to confirm diversion to slop tank; Check for leakage at flange connections; Actuation without delay or abnormal noise
- Area: Process controller (EPC 60/70) alarms, data logging and sensor functionsCheck: Weekly: Check all sensors (temperature, pressure, speed) for functionality; Monthly: Check data logging device and review log data; Quarterly: Test all alarms and sensor outputs (document with protocol); Annually: Verify sensor calibration
- Area: Piping and flange connections: Leakage and corrosionCheck: Daily: Visually inspect all pipes and valve connections for oil film, droplet formation or corrosion (especially hot water/drain areas); Weekly: Check flanges for reduction in clamping force or leakage under load; Immediately repair if signs of corrosion or leakage appear
- Area: Heater (if electrical) and preheating to setpoint temperatureCheck: Daily: Check outlet temperature of preheated bilge water (typical: 50-70°C, manufacturer-specific); Weekly: Inspect heating element surface for deposits, wear or charring; Monthly: Calibrate thermostats and temperature sensors; If setpoint temperature is not reached, check thermocouple or controller
Type-universal inspection/maintenance points for oily water separator (Alfa Laval, Mega-Schwarm 2026-06). Per-model specs not auto-filled.
- Durchsatz (PureBilge 2515)
- 2.500 l/h
- Durchsatz (PureBilge 5015)
- 5.000 l/h
- Separator-drehzahl
- 8.000 rpm
- Ölgehalt Ausgabe (typisch)
- <5 ppm (MARPOL-Limit: 15 ppm)
- Filtermedium
- Vorwärmefilter + Koalescenteinsätze
- Prozessregler
- EPC 60/70 (computergestützt, mit Cybersecurity)
- PureBilge 2515 (2500 l/h, 15ppm)
- PureBilge 5015 (5000 l/h, 15ppm)
- PureBilge Compact 0605 (600 l/h, 5ppm)
- Area: 15ppm-Ölgehalt-Monitor (Optical Cell) Verschmutzung/KalibrierungCheck: Visual: Check optical cell for fouling; Function test via high-oil simulation (monthly); Calibration by authorized manufacturer agent every 12 months or before IOPP renewal survey (MEPC.107(49) § 4.2.11 requirement)
- Area: Coalescer inserts (filter/coalescer) blockage, wear or degradationCheck: Routine inspection: Weekly check filter/coalescer elements for wear, clogging or damage; Replace upon blockage or visible wear (planned maintenance). Internal inspection: Clear separator chamber and inspect coalescer inserts for aging
- Area: Three-way valve (changeover valve) position and functionCheck: Daily: Check all valve positions; Monthly: Test three-way valve under simulated high-oil condition to confirm diversion to slop tank; Check for leakage at flange connections; Actuation without delay or abnormal noise
- Area: Process controller (EPC 60/70) alarms, data logging and sensor functionsCheck: Weekly: Check all sensors (temperature, pressure, speed) for functionality; Monthly: Check data logging device and review log data; Quarterly: Test all alarms and sensor outputs (document with protocol); Annually: Verify sensor calibration
- Area: Piping and flange connections: Leakage and corrosionCheck: Daily: Visually inspect all pipes and valve connections for oil film, droplet formation or corrosion (especially hot water/drain areas); Weekly: Check flanges for reduction in clamping force or leakage under load; Immediately repair if signs of corrosion or leakage appear
- Area: Heater (if electrical) and preheating to setpoint temperatureCheck: Daily: Check outlet temperature of preheated bilge water (typical: 50-70°C, manufacturer-specific); Weekly: Inspect heating element surface for deposits, wear or charring; Monthly: Calibrate thermostats and temperature sensors; If setpoint temperature is not reached, check thermocouple or controller
Type-universal inspection/maintenance points for oily water separator (Alfa Laval, Mega-Schwarm 2026-06). Per-model specs not auto-filled.
- Durchsatz (PureBilge 2515)
- 2.500 l/h
- Durchsatz (PureBilge 5015)
- 5.000 l/h
- Separator-drehzahl
- 8.000 rpm
- Ölgehalt Ausgabe (typisch)
- <5 ppm (MARPOL-Limit: 15 ppm)
- Filtermedium
- Vorwärmefilter + Koalescenteinsätze
- Prozessregler
- EPC 60/70 (computergestützt, mit Cybersecurity)
- PureBilge 2515 (2500 l/h, 15ppm)
- PureBilge 5015 (5000 l/h, 15ppm)
- PureBilge Compact 0605 (600 l/h, 5ppm)
- Area: 15ppm-Ölgehalt-Monitor (Optical Cell) Verschmutzung/KalibrierungCheck: Visual: Check optical cell for fouling; Function test via high-oil simulation (monthly); Calibration by authorized manufacturer agent every 12 months or before IOPP renewal survey (MEPC.107(49) § 4.2.11 requirement)
- Area: Coalescer inserts (filter/coalescer) blockage, wear or degradationCheck: Routine inspection: Weekly check filter/coalescer elements for wear, clogging or damage; Replace upon blockage or visible wear (planned maintenance). Internal inspection: Clear separator chamber and inspect coalescer inserts for aging
- Area: Three-way valve (changeover valve) position and functionCheck: Daily: Check all valve positions; Monthly: Test three-way valve under simulated high-oil condition to confirm diversion to slop tank; Check for leakage at flange connections; Actuation without delay or abnormal noise
- Area: Process controller (EPC 60/70) alarms, data logging and sensor functionsCheck: Weekly: Check all sensors (temperature, pressure, speed) for functionality; Monthly: Check data logging device and review log data; Quarterly: Test all alarms and sensor outputs (document with protocol); Annually: Verify sensor calibration
- Area: Piping and flange connections: Leakage and corrosionCheck: Daily: Visually inspect all pipes and valve connections for oil film, droplet formation or corrosion (especially hot water/drain areas); Weekly: Check flanges for reduction in clamping force or leakage under load; Immediately repair if signs of corrosion or leakage appear
- Area: Heater (if electrical) and preheating to setpoint temperatureCheck: Daily: Check outlet temperature of preheated bilge water (typical: 50-70°C, manufacturer-specific); Weekly: Inspect heating element surface for deposits, wear or charring; Monthly: Calibrate thermostats and temperature sensors; If setpoint temperature is not reached, check thermocouple or controller
Type-universal inspection/maintenance points for oily water separator (Alfa Laval, Mega-Schwarm 2026-06). Per-model specs not auto-filled.
- Durchsatz (PureBilge 2515)
- 2.500 l/h
- Durchsatz (PureBilge 5015)
- 5.000 l/h
- Separator-drehzahl
- 8.000 rpm
- Ölgehalt Ausgabe (typisch)
- <5 ppm (MARPOL-Limit: 15 ppm)
- Filtermedium
- Vorwärmefilter + Koalescenteinsätze
- Prozessregler
- EPC 60/70 (computergestützt, mit Cybersecurity)
- PureBilge 2515 (2500 l/h, 15ppm)
- PureBilge 5015 (5000 l/h, 15ppm)
- PureBilge Compact 0605 (600 l/h, 5ppm)
- Area: 15ppm-Ölgehalt-Monitor (Optical Cell) Verschmutzung/KalibrierungCheck: Visual: Check optical cell for fouling; Function test via high-oil simulation (monthly); Calibration by authorized manufacturer agent every 12 months or before IOPP renewal survey (MEPC.107(49) § 4.2.11 requirement)
- Area: Coalescer inserts (filter/coalescer) blockage, wear or degradationCheck: Routine inspection: Weekly check filter/coalescer elements for wear, clogging or damage; Replace upon blockage or visible wear (planned maintenance). Internal inspection: Clear separator chamber and inspect coalescer inserts for aging
- Area: Three-way valve (changeover valve) position and functionCheck: Daily: Check all valve positions; Monthly: Test three-way valve under simulated high-oil condition to confirm diversion to slop tank; Check for leakage at flange connections; Actuation without delay or abnormal noise
- Area: Process controller (EPC 60/70) alarms, data logging and sensor functionsCheck: Weekly: Check all sensors (temperature, pressure, speed) for functionality; Monthly: Check data logging device and review log data; Quarterly: Test all alarms and sensor outputs (document with protocol); Annually: Verify sensor calibration
- Area: Piping and flange connections: Leakage and corrosionCheck: Daily: Visually inspect all pipes and valve connections for oil film, droplet formation or corrosion (especially hot water/drain areas); Weekly: Check flanges for reduction in clamping force or leakage under load; Immediately repair if signs of corrosion or leakage appear
- Area: Heater (if electrical) and preheating to setpoint temperatureCheck: Daily: Check outlet temperature of preheated bilge water (typical: 50-70°C, manufacturer-specific); Weekly: Inspect heating element surface for deposits, wear or charring; Monthly: Calibrate thermostats and temperature sensors; If setpoint temperature is not reached, check thermocouple or controller
Type-universal inspection/maintenance points for oily water separator (Alfa Laval, Mega-Schwarm 2026-06). Per-model specs not auto-filled.
- Durchsatz (PureBilge 2515)
- 2.500 l/h
- Durchsatz (PureBilge 5015)
- 5.000 l/h
- Separator-drehzahl
- 8.000 rpm
- Ölgehalt Ausgabe (typisch)
- <5 ppm (MARPOL-Limit: 15 ppm)
- Filtermedium
- Vorwärmefilter + Koalescenteinsätze
- Prozessregler
- EPC 60/70 (computergestützt, mit Cybersecurity)
- PureBilge 2515 (2500 l/h, 15ppm)
- PureBilge 5015 (5000 l/h, 15ppm)
- PureBilge Compact 0605 (600 l/h, 5ppm)
- Area: 15ppm-Ölgehalt-Monitor (Optical Cell) Verschmutzung/KalibrierungCheck: Visual: Check optical cell for fouling; Function test via high-oil simulation (monthly); Calibration by authorized manufacturer agent every 12 months or before IOPP renewal survey (MEPC.107(49) § 4.2.11 requirement)
- Area: Coalescer inserts (filter/coalescer) blockage, wear or degradationCheck: Routine inspection: Weekly check filter/coalescer elements for wear, clogging or damage; Replace upon blockage or visible wear (planned maintenance). Internal inspection: Clear separator chamber and inspect coalescer inserts for aging
- Area: Three-way valve (changeover valve) position and functionCheck: Daily: Check all valve positions; Monthly: Test three-way valve under simulated high-oil condition to confirm diversion to slop tank; Check for leakage at flange connections; Actuation without delay or abnormal noise
- Area: Process controller (EPC 60/70) alarms, data logging and sensor functionsCheck: Weekly: Check all sensors (temperature, pressure, speed) for functionality; Monthly: Check data logging device and review log data; Quarterly: Test all alarms and sensor outputs (document with protocol); Annually: Verify sensor calibration
- Area: Piping and flange connections: Leakage and corrosionCheck: Daily: Visually inspect all pipes and valve connections for oil film, droplet formation or corrosion (especially hot water/drain areas); Weekly: Check flanges for reduction in clamping force or leakage under load; Immediately repair if signs of corrosion or leakage appear
- Area: Heater (if electrical) and preheating to setpoint temperatureCheck: Daily: Check outlet temperature of preheated bilge water (typical: 50-70°C, manufacturer-specific); Weekly: Inspect heating element surface for deposits, wear or charring; Monthly: Calibrate thermostats and temperature sensors; If setpoint temperature is not reached, check thermocouple or controller
Type-universal inspection/maintenance points for oily water separator (Alfa Laval, Mega-Schwarm 2026-06). Per-model specs not auto-filled.
Techni
15Dräger Safety AG & Co. KGaA
8DESARROLLO TECNICAS INDUSTRIALES DE GALICIA
7
GERTSEN & OLUFSEN
6
Victor Marine
6- Separation-stage, bowl, coalescer or filter fouling reduces treatment efficiency and causes poor outlet quality or alarms
- Monitor, sensor or sampling-line contamination causes unstable readings or unnecessary recirculation and trips
- Seal, gasket or bowl-sealing faults cause leakage or loss of correct separation conditions
- Feed-pump, drive or bearing faults cause unstable flow, vibration, abnormal noise or shutdown
- Incorrect temperature, flow, interface or chemical condition causes poor separation despite apparently normal machinery
- Simple, rugged construction – easy to install and operate
- Low maintenance schedule (coalescer change annually, OCM calibrated monthly)
- Compact footprint suitable for retrofits on medium‑size vessels
- Consistently achieves 15 ppm oil discharge limit when maintained
- Cost‑effective compared with more complex electronic OWS units
- Coalescer element can clog if not replaced on schedule, reducing efficiency
- Optical Counter‑Measure (OCM) sensor drift requires regular calibration
- Pump seal leakage reported in field service bulletins
- Control panel electronics may develop faults under harsh vibration
- Limited maximum flow capacity for very high‑throughput vessels
- Coalescer/filter fouling from solids and oil loading, typically indicated by high differential pressure, low capacity or poor separation
- Oil-content monitor contamination or calibration drift, typically indicated by unstable reading, false alarm or failed test
- Automatic divert/stop valve malfunction, typically indicated by failure to route off-spec water away from overboard discharge
- Pump or valve leakage/air ingress, typically indicated by unstable flow, loss of suction or reduced separation
- Illegal or incorrect piping/valve alignment, typically indicated by survey nonconformity, unexplained flow path or compliance risk
- Coalescer/filter fouling from solids and oil loading, typically indicated by high differential pressure, low capacity or poor separation
- Oil-content monitor contamination or calibration drift, typically indicated by unstable reading, false alarm or failed test
- Automatic divert/stop valve malfunction, typically indicated by failure to route off-spec water away from overboard discharge
- Pump or valve leakage/air ingress, typically indicated by unstable flow, loss of suction or reduced separation
- Illegal or incorrect piping/valve alignment, typically indicated by survey nonconformity, unexplained flow path or compliance risk
- Coalescer/filter fouling from solids and oil loading, typically indicated by high differential pressure, low capacity or poor separation
- Oil-content monitor contamination or calibration drift, typically indicated by unstable reading, false alarm or failed test
- Automatic divert/stop valve malfunction, typically indicated by failure to route off-spec water away from overboard discharge
- Pump or valve leakage/air ingress, typically indicated by unstable flow, loss of suction or reduced separation
- Illegal or incorrect piping/valve alignment, typically indicated by survey nonconformity, unexplained flow path or compliance risk
- Coalescer/filter fouling from solids and oil loading, typically indicated by high differential pressure, low capacity or poor separation
- Oil-content monitor contamination or calibration drift, typically indicated by unstable reading, false alarm or failed test
- Automatic divert/stop valve malfunction, typically indicated by failure to route off-spec water away from overboard discharge
- Pump or valve leakage/air ingress, typically indicated by unstable flow, loss of suction or reduced separation
- Illegal or incorrect piping/valve alignment, typically indicated by survey nonconformity, unexplained flow path or compliance risk
- Coalescer/filter fouling from solids and oil loading, typically indicated by high differential pressure, low capacity or poor separation
- Oil-content monitor contamination or calibration drift, typically indicated by unstable reading, false alarm or failed test
- Automatic divert/stop valve malfunction, typically indicated by failure to route off-spec water away from overboard discharge
- Pump or valve leakage/air ingress, typically indicated by unstable flow, loss of suction or reduced separation
- Illegal or incorrect piping/valve alignment, typically indicated by survey nonconformity, unexplained flow path or compliance risk
RWO
5- Coalescer, filter, or separation-stage fouling from sludge and solids raises pressure drop, reduces throughput, or causes poor separation
- Oil-content monitor contamination, calibration drift, or sampling-line blockage causes unstable readings, alarms, or diversion despite apparently clean water
- Valve, solenoid, or automatic stopping-device faults from sticking, air failure, or electrical problems prevent correct recirculation or overboard control
- Feed-pump wear, air ingress, or suction blockage causes low flow, loss of prime, cavitation, or inability to process the bilge tank
- Excessive emulsified oil, detergents, chemicals, or unsuitable bilge composition overwhelms separation performance and results in persistently high oil-content readings
- Coalescer, filter or separation-stage fouling causes rising oil-content readings or automatic recirculation
- Oil-content monitor contamination or blocked sampling lines cause unstable readings, alarms or discharge shutdown
- Diverting-valve or solenoid faults prevent correct recirculation and cause sequence alarms
- Feed-pump seal wear or suction-side air ingress causes unstable flow or poor separation
- Detergents or stable emulsions overwhelm the process and cause persistent high oil-content readings
- Coalescer, filter or separation-stage fouling causes rising oil-content readings or automatic recirculation
- Oil-content monitor contamination or blocked sampling lines cause unstable readings, alarms or discharge shutdown
- Diverting-valve or solenoid faults prevent correct recirculation and cause sequence alarms
- Feed-pump seal wear or suction-side air ingress causes unstable flow or poor separation
- Detergents or stable emulsions overwhelm the process and cause persistent high oil-content readings
- Coalescer, filter or separation-stage fouling causes rising oil-content readings or automatic recirculation
- Oil-content monitor contamination or blocked sampling lines cause unstable readings, alarms or discharge shutdown
- Diverting-valve or solenoid faults prevent correct recirculation and cause sequence alarms
- Feed-pump seal wear or suction-side air ingress causes unstable flow or poor separation
- Detergents or stable emulsions overwhelm the process and cause persistent high oil-content readings
- Coalescer, filter or separation-stage fouling causes rising oil-content readings or automatic recirculation
- Oil-content monitor contamination or blocked sampling lines cause unstable readings, alarms or discharge shutdown
- Diverting-valve or solenoid faults prevent correct recirculation and cause sequence alarms
- Feed-pump seal wear or suction-side air ingress causes unstable flow or poor separation
- Detergents or stable emulsions overwhelm the process and cause persistent high oil-content readings
Wärtsilä
5- Separation-element fouling caused by sludge, detergents or excessive oil loading, resulting in poor separation and repeated high-oil-content alarms
- Oil-content monitor contamination or calibration drift caused by dirty sample lines or sensor fouling, resulting in unstable or implausible readings
- Automatic recirculation or discharge-valve failure caused by actuator, solenoid or control faults, resulting in inability to route off-specification water correctly
- Feed-pump or suction problems caused by blockage, air ingress or pump wear, resulting in unstable flow and poor separator performance
- Internal leakage or bypassing caused by damaged seals, incorrect assembly or unauthorized piping changes, resulting in non-compliant operation or abnormal sample results
- Separation-element fouling caused by sludge, detergents or excessive oil loading, resulting in poor separation and repeated high-oil-content alarms
- Oil-content monitor contamination or calibration drift caused by dirty sample lines or sensor fouling, resulting in unstable or implausible readings
- Automatic recirculation or discharge-valve failure caused by actuator, solenoid or control faults, resulting in inability to route off-specification water correctly
- Feed-pump or suction problems caused by blockage, air ingress or pump wear, resulting in unstable flow and poor separator performance
- Internal leakage or bypassing caused by damaged seals, incorrect assembly or unauthorized piping changes, resulting in non-compliant operation or abnormal sample results
- Separation-element fouling caused by sludge, detergents or excessive oil loading, resulting in poor separation and repeated high-oil-content alarms
- Oil-content monitor contamination or calibration drift caused by dirty sample lines or sensor fouling, resulting in unstable or implausible readings
- Automatic recirculation or discharge-valve failure caused by actuator, solenoid or control faults, resulting in inability to route off-specification water correctly
- Feed-pump or suction problems caused by blockage, air ingress or pump wear, resulting in unstable flow and poor separator performance
- Internal leakage or bypassing caused by damaged seals, incorrect assembly or unauthorized piping changes, resulting in non-compliant operation or abnormal sample results
- Separation-element fouling caused by sludge, detergents or excessive oil loading, resulting in poor separation and repeated high-oil-content alarms
- Oil-content monitor contamination or calibration drift caused by dirty sample lines or sensor fouling, resulting in unstable or implausible readings
- Automatic recirculation or discharge-valve failure caused by actuator, solenoid or control faults, resulting in inability to route off-specification water correctly
- Feed-pump or suction problems caused by blockage, air ingress or pump wear, resulting in unstable flow and poor separator performance
- Internal leakage or bypassing caused by damaged seals, incorrect assembly or unauthorized piping changes, resulting in non-compliant operation or abnormal sample results
Compass
4- Separation-element fouling caused by sludge, detergents or excessive oil loading, resulting in poor separation and repeated high-oil-content alarms
- Oil-content monitor contamination or calibration drift caused by dirty sample lines or sensor fouling, resulting in unstable or implausible readings
- Automatic recirculation or discharge-valve failure caused by actuator, solenoid or control faults, resulting in inability to route off-specification water correctly
- Feed-pump or suction problems caused by blockage, air ingress or pump wear, resulting in unstable flow and poor separator performance
- Internal leakage or bypassing caused by damaged seals, incorrect assembly or unauthorized piping changes, resulting in non-compliant operation or abnormal sample results
- Coalescer, filter or separation-stage fouling causes rising oil-content readings or automatic recirculation
- Oil-content monitor contamination or blocked sampling lines cause unstable readings, alarms or discharge shutdown
- Diverting-valve or solenoid faults prevent correct recirculation and cause sequence alarms
- Feed-pump seal wear or suction-side air ingress causes unstable flow or poor separation
- Detergents or stable emulsions overwhelm the process and cause persistent high oil-content readings
- Coalescer, filter or separation-stage fouling causes rising oil-content readings or automatic recirculation
- Oil-content monitor contamination or blocked sampling lines cause unstable readings, alarms or discharge shutdown
- Diverting-valve or solenoid faults prevent correct recirculation and cause sequence alarms
- Feed-pump seal wear or suction-side air ingress causes unstable flow or poor separation
- Detergents or stable emulsions overwhelm the process and cause persistent high oil-content readings
- Coalescer, filter or separation-stage fouling causes rising oil-content readings or automatic recirculation
- Oil-content monitor contamination or blocked sampling lines cause unstable readings, alarms or discharge shutdown
- Diverting-valve or solenoid faults prevent correct recirculation and cause sequence alarms
- Feed-pump seal wear or suction-side air ingress causes unstable flow or poor separation
- Detergents or stable emulsions overwhelm the process and cause persistent high oil-content readings
TECNICOMAR
4Hansun (Jiangsu) Marine Technology
3
Martek Marine
3RIKEN KEIKI
3Ados
2Benchmark International Inc / Turner Designs Hydrocarbon Instruments
2Brannstrom Sweden
2Consilium Safety Netherlands
2Crowcon Detection Instruments(Beijing)
2CSSC Nanjing Luzhou Machine
2Fellow Kogyo
2General Monitors
2Hamann
2Industrial Scientific China
2Inov8 Systems
2Jiujiang Gongchuang Machinery Equipment
2Marinfloc
2Rivertrace
2UNIPHOS ENVIROTRONIC
2Autronica Fire and Security
1Compass Water Solutions
1- Separation-stage, bowl, coalescer or filter fouling reduces treatment efficiency and causes poor outlet quality or alarms
- Monitor, sensor or sampling-line contamination causes unstable readings or unnecessary recirculation and trips
- Seal, gasket or bowl-sealing faults cause leakage or loss of correct separation conditions
- Feed-pump, drive or bearing faults cause unstable flow, vibration, abnormal noise or shutdown
- Incorrect temperature, flow, interface or chemical condition causes poor separation despite apparently normal machinery
- No disposable filter media – lower recurring cost
- High removal efficiency for emulsified oils common in bilge water
- Predictable electrode wear schedule simplifies maintenance planning
- Compact unit suitable for retro‑fit on existing vessels
- Electrode degradation requires periodic replacement, causing planned downtime
- Sensitive to power supply quality; failures can halt treatment
- Sludge generated by coagulation must be removed and disposed of regularly
- pH control system adds complexity and may need adjustment in variable bilge conditions
Detector Electronics
1Facet/Parker
1- Separation-stage, bowl, coalescer or filter fouling reduces treatment efficiency and causes poor outlet quality or alarms
- Monitor, sensor or sampling-line contamination causes unstable readings or unnecessary recirculation and trips
- Seal, gasket or bowl-sealing faults cause leakage or loss of correct separation conditions
- Feed-pump, drive or bearing faults cause unstable flow, vibration, abnormal noise or shutdown
- Incorrect temperature, flow, interface or chemical condition causes poor separation despite apparently normal machinery
- Consistently achieves 15 ppm compliance under MARPOL Annex I requirements
- Multi‑stage filtration reduces oil carry‑over and improves effluent quality
- Differential pressure monitoring enables predictive filter element replacement
- Integrated OCM sensor with recommended annual calibration ensures reliable detection
- Compact modular design facilitates retrofits on existing vessels
- Filter elements can become blocked if differential pressure is not regularly checked, leading to alarm trips
- Solenoid valve may stick, requiring periodic manual inspection and maintenance
- OCM sensor contamination is possible in high‑oil load conditions
- Maintenance intervals may be shorter on vessels with heavy bilge water generation
- Lack of publicly documented certifications could limit acceptance in jurisdictions that require specific approvals
Geo Rim Engineering
1Green Instruments
1Jowa
1mPower Electronics (Shanghai)
1MSA Europe
1MSA Safety, Inc. dba MSA Innovation
1MSR-Electronic
1Optronics Technology
1Rosemount
1RWO/Veolia
1- Separation-stage, bowl, coalescer or filter fouling reduces treatment efficiency and causes poor outlet quality or alarms
- Monitor, sensor or sampling-line contamination causes unstable readings or unnecessary recirculation and trips
- Seal, gasket or bowl-sealing faults cause leakage or loss of correct separation conditions
- Feed-pump, drive or bearing faults cause unstable flow, vibration, abnormal noise or shutdown
- Incorrect temperature, flow, interface or chemical condition causes poor separation despite apparently normal machinery
- Integrated two‑stage treatment (coalescer + carbon) meets the strict 15 ppm MARPOL limit
- Modular cartridge design allows quick replacement of coalescer and carbon elements
- Proven reliability on a wide range of commercial vessels with an extensive Veolia service network
- Compact footprint suitable for limited engine‑room space
- Activated‑carbon element requires periodic replacement, adding consumable cost
- Solenoid valve and OCM (oil content monitor) can drift and need regular calibration checks
- Maximum flow capacity may be insufficient for very high‑discharge vessels
- Carbon exhaustion can lead to occasional oil breakthrough if not monitored
Scanship