Fire Division Panel
medium
107 models total
Fire Division Panel for marine and industrial applications. Models listed here carry an official DNV type approval certificate or a verified manufacturer datasheet.
46 manufacturers · 107 models
KCC Corporation Ltd. Gimcheon Plant
17
KCC CERAKWOOL New-Bio Alpha 1200 H-120 Deck
Model Number
TAF000004M
KCC CERAKWOOL New-Bio Alpha 1200 H-60 Deck
Model Number
TAF000004K
A-60 Class Deck Type D-107
Model Number
TAF000020D
A-60 Class Bulkhead Type W-212-II
Model Number
TAF00001ZX
A-60 Class Deck Type D-105-II
Model Number
TAF00001ZS
A-30 Class Bulkhead Type W-104
Model Number
TAF00001ZW
A-60 Class Bulkhead Type W-101
Model Number
TAF00001ZY
A-30 Class Deck Type D-111
Model Number
TAF00001ZT
Class A-60 Deck: CD-101, CD-111
Model Number
TAF00001ZF
Class A-60 Bulkhead: CW-201, CW-211
Model Number
TAF00001Z7
Class A-60 Bulkhead: CW-101, CW-111
Model Number
TAF00001Z6
A-60 Bulkhead Steel side W-106-M
Model Number
TAF00001U6
A-60 Bulkhead Insul side W-105-M
Model Number
TAF00001U7
KC-D-201
Model Number
TAF00000SX
A-60 Class Bulkhead Type W-102-M
Model Number
TAF00001MA
A-60 Bulkhead Type W-101-M
Model Number
TAF00001MB
A-60 Class Deck Type D-101-M
Model Number
TAF00001M4
DOOSUNG
5
A-30 Class Deck of type "DSSIX-AD30"
Model Number
TAF00001A2
A-30 Class Bulkhead of type "DSSIX-AS30"
Model Number
TAF00001A1
A-60 Class Bulkhead of type "DSSIX-AS60"
Model Number
TAF000014U
A-60 Class Deck of type "DSSIX-AD60"
Model Number
TAF000014V
A-60 Class Bulkhead of type "DSSIX-AI60"
Model Number
TAF000014N
IKM DSC Engineering
4
A-Class partition Clip wall W-B100 L, perforated one side
Model Number
TAF000011A
A-Class partition Clip wall W-B100 L, non perforated
Model Number
TAF000011C
Non loadbearing cladding system, Class A-60
Model Number
TAF00000ZB
Non loadbearing cladding system, Class A-0
Model Number
TAF00000ZC
Libra-Plast
4Se Woon T&S
4Tianjin Haimen Building Material
4Unifrax
4
FyreWrap Blanket (Fiberfrax Durablanket S) - Class A-30 Aluminium Deck
Model Number
TAF00000G9
FyreWrap Blanket (Fiberfrax Durablanket S) - Class A-30 Aluminium Bulkhead (Restricted)
Model Number
TAF00000G8
FyreWrap Blanket (Fiberfrax Durablanket S) - Class A-60 Aluminium Bulkhead (Restricted)
Model Number
TAF00000GA
FyreWrap Blanket (Fiberfrax Durablanket S) - Class A-60 Aluminium Deck
Model Number
TAF00000GB
AkzoNobel / International Paint
3Daehyup Spray
3SEJIN HEAVY IND
3Shanghai Lihui Marine Equipment
3Thermal Ceramics UK
3Unifrax France
3Wuxi MNET Equipment Tech
3Advanced Innergy
2Byucksan Youngdong Plant
2Carboline Global
2Dalian Mingyang Deck Covering
2Huanan Building Materials (Shenzhen)
2Jotun
2
Jotachar JF750 XT / Fiberfrax Durablanket S - H-60 deck
Per coating specification
· Hull/Tank Protection Coating
· Intumescent/epoxy fire protection coating
Model Number
TAF00001YC
Technical Specifications
- Jotamastic 90 DFT
- 100 µm (Trockenfilm-Dicke)
- Marathon IQ2 Maximum DFT
- bis 500 µm, solidentfrei (98% Volumen)
- Penguard Primer DFT
- 60–120 µm typisch
- SeaQuantum Ultra VOC-Gehalt
- Niedrig (<340 g/l); IMO AFS/CONF/26 konform
- Haftungs-anforderung
- ≥5 MPa; ASTM D3359 Level 0–1
- Salzsprühwiderstand (ASTM B117)
- >1,000 hours typical; Marine Heavy-Duty 500–2,000 h
Product Lines
- Jotamastic 90/87/80 (Epoxy Mastic Primer)
- Marathon IQ2 (solventfrei Epoxy Topcoat)
- Penguard Primer/HB/Universal (High-MW Epoxy Primer)
- SeaQuantum Ultra III/S/SP (Antifouling Silyl-Acrylat)
- SeaForce Shield/Active/Active Plus (Biozidbasierte Antifouling)
Common Failures & Inspection Points
- Area: Unzureichende Schichtdicke (DFT) = Keine Korrosionsschutz-GarantieCheck: Measure with coating thickness gauge (gage) per SSPC-PA2. Example: Jotamastic 90 shall be 100 µm = passed; <75 µm = rework required. Statistical sampling: minimum 20 points/m².
- Area: Schlechte Haftung (Adhesion-Versagen) = Abblätterung/DelaminierungCheck: Cross-Hatch-Adhäsionstest (ASTM D3359) durchführen: 6mm Rasterabstände, Klebeband aufreißen. Bewertung: Level 0 = beste Haftung (0% Verlust). Level ≥3 = Schicht-Versagen → Nacharbeiten. Alternativ: Pull-off Test >5 MPa.
- Area: Unvollständige Aushärtung = Weiche/klebrige Oberfläche, reduzierte HärteCheck: Pencil hardness test (ASTM D3363) perform: guide pencil at 45° angle with pressure over surface. Expected for epoxy after 7 days: ≥H (hard). Observe test duration per TDS (typically 24–48h hard-dry, 7 days full cure).
- Area: Surface preparation non-conforming (too rough/too smooth surface) = adhesion defectCheck: Surface roughness inspect: ISO 8501-1 grade Sa 2½ (medium roughness) or white-metal. Surface roughness: 30–85 µm (ISO 8503-2, fine–medium). Visual + surface roughness gauge (profile gauge) use.
- Area: Holiday/Pinhole-Defekte = lokale Korrosion trotz BeschichtungCheck: Holiday detector (spark tester for >250 µm; low-volt sponge for <500 µm) guide over entire area systematically. Defects localize and mark with red marking → must be repaired before operation.
- Area: PSPC/IMO non-conformity = tanks fail classification (ballast/cargo)Check: IMO PSPC certificate of coating system inspect (ballast tank coatings, COT = cargo oil tank). Salt spray test references (ASTM B117) ≥500 hours for ballast, ≥1000–2000h for heavy marine applications inspect. Certificates: ClassNK, Lloyd's Register.
Type-universal inspection/maintenance points for paint & coating systems (Jotun, Mega-Schwarm 2026-06). Per-model specs not auto-filled.
Service: Coating inspection at docking. Anode check every 6 months. Touch-up work on damage immediately. Antifouling renewal at docking (every 5 years).
Spare Parts: Jotun A/S: Touch-Up Farbe in allen verwendeten Systemen an Bord vorhalten. Anoden per Dockungsbedarf.
Strengths
- DNV-/Lloyd's-zertifizierter Brandschutz
- Verschiedene Feuerszenarien abgedeckt (Pool Fire, Jet Fire)
- Lange Standzeit
Weaknesses
- Hoher Materialpreis
- Erfordert Spezialapplikation
- Regelmaessige Inspektion Pflicht
Typical Vessels:
FPSOOffshore SupplyTankerCruise
Decision Guide: Choose if: SOLAS/IMO/NORSOK fire protection for steel structures on vessels and offshore. Avoid if: Not for decorative or corrosion protection purposes.
Use Cases: Passive fire protection by Jotun. XT (Extended Technology) — extended fire protection with enhanced insulation performance. For deck areas. Combination with ceramic insulating board for increased fire resistance duration. Intumescent coating that expands when exposed to heat, forming an insulating carbon layer and protecting steel from temperature failure.
Jotachar JF750 XT – Bulkhead
Model Number
TAF00001V7
Shandong Minye Refractory Fibre
2Sherwin-Williams UK
2Wincell Insulation
2Wuxi Dongzhou Marine Equipment
2Yantai Navigation Machinery
2You Shin Dan Yeol Co., Ltd. Factory No.1
2China Marine Windows Shipyard
1
CMWS-AWTH-A60 Deck Hatch
Model Number
TAF00001XH
China Shipbuilding Jiujiang Haike Interior Decoration
1
“FD60 / A-60 Class Floating floor”
Model Number
TAF0000112
Daehyup Tech
1
BILLYTEX DPU-BF FFA
Model Number
TAF000021B
JBM
1
A-30 Fireproof Hatch Cover (JBM-1000*1000)
Model Number
TAF00000DK
Jiangyin Huangshan Marine Fitting
1
Class A-60 fire hatch cover,
Model Number
TAF0000093
Jiangyin Marine Equipment Manufacturing
1
A-60 Class Fireproof Hatch Cover
Model Number
TAF00001NS
KwangLim Marine Tech
1
A60-KL-HATCH-01
Model Number
TAF000016G
Luyang Energy-saving Materials
1
Class A-60 bulkhead - Biowool Marine Blanket Wrapped
Model Number
TAF00000C2
Mech-Tool Engineering
1
MTE Bulkhead Panel A60
Model Number
TAF0000044
Nanjing Lishui YiSheng Ship Fittings Factory
1
Class A60 Double-sided Opening and Closing Fireproof Steel Hatch Cover
Model Number
TAF00001NF
Navalimpianti
1
A-60 deck hatch
Model Number
TAF00001X2
ProfiSeal
1
Dynamic Shaft Penetration ProfiSeal Series 500 fire resistant A-60 Bulkhead Seal
Model Number
TAF00001FF
Rockfibras do Brasil Industria e Comercio Ltda
1
A-60 Steel Bulkhead PNR-128
Model Number
TAF00000SJ
Rockwool Danmark
1
H-60 Steel Deck
Model Number
TAF0000202
SAMHWA PAINTS INDUSTRIAL
1
CHARREX PFP-1000 - Deck
Model Number
TAF000002T
Shanghai Yibo Shipping
1
YB-JFQ-II, YB-JFQ-III and YB-JFQ-IV
Model Number
TAF00000UX
Sung Mi
1
A-60 Class Fire Door: SM-A60-HC
Model Number
TAF000009N
Taixing Traffic Machinery Facilities Factory
1
263TJS008 - Class A60 fire hatch cover
Model Number
TAF00001VF
Tianjin Huali Thermal Insulation Building Material
1
Fire Well BKH-60 Type Class A-60 Bulkhead
Model Number
TAF000016R
Vipo
1
Vikodeck
Model Number
TAF00001T2