OceanSphere
Engines

Ballast Tank Coating

medium 224 / 224 models (Inspector)

Ballast tank coating is a dedicated epoxy system applied to the worst corrosion environment on a ship: alternating wet and dry cycles, oxygen-rich seawater, and steel surfaces the crew can inspect only at rare tank openings.

Read more — Ballast Tank Coating explained

What defines this type

Ballast tank coating is not a hull paint applied to a different substrate — it is a system engineered for the harshest corrosion regime on the ship. The tank sees full immersion in oxygenated seawater at sea, near-total dryness in port, condensation on the underside of the deck plating, and mechanical wear from ballast flow around suction bells and stringers. General cargo hold or external deck coatings are formulated for weathering and abrasion; ballast tank systems are formulated for cyclic wet/dry exposure and cathodic protection compatibility, and they carry a mandatory design life that hull topside paint does not.

Ballast tank coating, layer build-up
Ballast tank coating shown on the tank shell with a sacrificial anode and a weld seam, and a magnified detail of the layer build-up at the seam: steel substrate, primer coat, an extra stripe coat at the weld, and the finish coat.

Main components

Surface preparation

Blast cleaning to Sa 2.5 (near-white metal) with an angular profile of 30-75 microns is the baseline; anything less and the epoxy cannot key into the steel and will disbond within the first survey cycle.

Primer / stripe coat

A zinc-rich or epoxy primer goes down first, followed by a stripe coat brushed or rolled onto welds, edges, cut-outs and stiffener toes — the geometry where dry film thickness naturally runs thin and where corrosion starts first.

Full coat epoxy system

Two or more spray-applied coats of a high-solids epoxy build the system to its specified dry film thickness (DFT), typically light grey or another light colour so that later tank inspections can spot rust bleed and breakdown by eye.

Cathodic protection

Sacrificial zinc or aluminium anodes are hung inside the tank to protect the small percentage of steel the coating inevitably misses — coating and anodes are a paired system, not alternatives.

Selection / Sizing

The variables that matter for a ballast tank system:

ParameterTypical range / requirement
Total DFT320 microns minimum for new construction under IMO PSPC
Surface profile30-75 microns, angular
Topcoat colourLight colour for inspectability
Overcoating windowCoating-specific; exceeding it forces re-blasting before the next coat
Application dew point marginSteel temperature at least 3°C above dew point

Yard schedule and tank access (double bottom vs. topside ballast tank, manhole size) drive whether spray or airless application with extension lances is used, which in turn affects achievable DFT consistency on stiffener webs.

Regulations / Class

New construction bulk carriers and tankers of 150m and above, and all ships with dedicated seawater ballast tanks, fall under the IMO Performance Standard for Protective Coatings for dedicated seawater ballast tanks (PSPC, resolution MSC.215(82)). PSPC sets minimum DFT, requires a Coating Technical File documenting every stage of surface prep and application, and defines "GOOD" condition as no breakdown or rust for at least five years. Class societies survey coating condition at each special survey and downgrade it to FAIR or POOR based on visible rust and blistering percentage, which then drives thickness-gauging and close-up survey requirements under the IACS harmonised common structural rules for tankers and bulkers.

Typical faults

  • Holidays and pinholes — caused by insufficient DFT or contamination on the steel; each one becomes a corrosion cell under immersion.
  • Edge and weld breakdown — coating naturally thins over sharp edges and weld toes; without a stripe coat these fail first, years before the flat plating.
  • Cathodic disbondment — coating blisters and lifts around anodes when the system is not formulated for cathodic protection compatibility.
  • Intercoat delamination — the maximum overcoating interval was exceeded, so the next coat never chemically bonds to the one beneath it.
  • Flash rust under coating — steel was coated too soon after blasting in humid conditions, trapping surface rust bloom beneath the film.

What to look for in a supplier

  • A PSPC-compliant system with third-party type approval and a documented Coating Technical File template.
  • Application supervision by a NACE or FROSIO Level 2 certified coating inspector, not just the applicator's own foreman.
  • Batch and mix-ratio traceability for every drum used on the job, tied to the tank it went into.
  • A stated overcoating window and recoat interval that the yard's schedule can actually meet.
  • Compatibility data with the specific anode alloy fitted, not a generic cathodic protection statement.

A tank that looks perfect from the manhole can still be failing on the underside of the deckhead — always inspect stiffener toes and the boundary near anodes with a torch held at a raking angle, not straight on.

Inspector Mode Show All 224 / 224 with inspector value

36 manufacturers · 224 models

Jotun

26
Jotacote Universal N10 BT
Type
Ballast Tank Epoxy
Pspc compliant
ja
Technical Specifications
Jotamastic 90 DFT
100 µm (Trockenfilm-Dicke)
Marathon IQ2 Maximum DFT
bis 500 µm, solidentfrei (98% Volumen)
Penguard Primer DFT
60–120 µm typisch
SeaQuantum Ultra VOC-Gehalt
Niedrig (<340 g/l); IMO AFS/CONF/26 konform
Haftungs-anforderung
≥5 MPa; ASTM D3359 Level 0–1
Salzsprühwiderstand (ASTM B117)
>1,000 hours typical; Marine Heavy-Duty 500–2,000 h
Product Lines
  • Jotamastic 90/87/80 (Epoxy Mastic Primer)
  • Marathon IQ2 (solventfrei Epoxy Topcoat)
  • Penguard Primer/HB/Universal (High-MW Epoxy Primer)
  • SeaQuantum Ultra III/S/SP (Antifouling Silyl-Acrylat)
  • SeaForce Shield/Active/Active Plus (Biozidbasierte Antifouling)
🎯 Application Area
Application data not yet recorded.
Common Failures & Inspection Points
  • Area: Unzureichende Schichtdicke (DFT) = Keine Korrosionsschutz-Garantie
    Check: Measure with coating thickness gauge (gage) per SSPC-PA2. Example: Jotamastic 90 shall be 100 µm = passed; <75 µm = rework required. Statistical sampling: minimum 20 points/m².
  • Area: Schlechte Haftung (Adhesion-Versagen) = Abblätterung/Delaminierung
    Check: Cross-Hatch-Adhäsionstest (ASTM D3359) durchführen: 6mm Rasterabstände, Klebeband aufreißen. Bewertung: Level 0 = beste Haftung (0% Verlust). Level ≥3 = Schicht-Versagen → Nacharbeiten. Alternativ: Pull-off Test >5 MPa.
  • Area: Unvollständige Aushärtung = Weiche/klebrige Oberfläche, reduzierte Härte
    Check: Pencil hardness test (ASTM D3363) perform: guide pencil at 45° angle with pressure over surface. Expected for epoxy after 7 days: ≥H (hard). Observe test duration per TDS (typically 24–48h hard-dry, 7 days full cure).
  • Area: Surface preparation non-conforming (too rough/too smooth surface) = adhesion defect
    Check: Surface roughness inspect: ISO 8501-1 grade Sa 2½ (medium roughness) or white-metal. Surface roughness: 30–85 µm (ISO 8503-2, fine–medium). Visual + surface roughness gauge (profile gauge) use.
  • Area: Holiday/Pinhole-Defekte = lokale Korrosion trotz Beschichtung
    Check: Holiday detector (spark tester for >250 µm; low-volt sponge for <500 µm) guide over entire area systematically. Defects localize and mark with red marking → must be repaired before operation.
  • Area: PSPC/IMO non-conformity = tanks fail classification (ballast/cargo)
    Check: IMO PSPC certificate of coating system inspect (ballast tank coatings, COT = cargo oil tank). Salt spray test references (ASTM B117) ≥500 hours for ballast, ≥1000–2000h for heavy marine applications inspect. Certificates: ClassNK, Lloyd's Register.

Type-universal inspection/maintenance points for paint & coating systems (Jotun, Mega-Schwarm 2026-06). Per-model specs not auto-filled.

Jotamastic 90 BT
Type
Hi-Build Ballast Epoxy
Dft (µm)
350
Technical Specifications
Jotamastic 90 DFT
100 µm (Trockenfilm-Dicke)
Marathon IQ2 Maximum DFT
bis 500 µm, solidentfrei (98% Volumen)
Penguard Primer DFT
60–120 µm typisch
SeaQuantum Ultra VOC-Gehalt
Niedrig (<340 g/l); IMO AFS/CONF/26 konform
Haftungs-anforderung
≥5 MPa; ASTM D3359 Level 0–1
Salzsprühwiderstand (ASTM B117)
>1,000 hours typical; Marine Heavy-Duty 500–2,000 h
Product Lines
  • Jotamastic 90/87/80 (Epoxy Mastic Primer)
  • Marathon IQ2 (solventfrei Epoxy Topcoat)
  • Penguard Primer/HB/Universal (High-MW Epoxy Primer)
  • SeaQuantum Ultra III/S/SP (Antifouling Silyl-Acrylat)
  • SeaForce Shield/Active/Active Plus (Biozidbasierte Antifouling)
🎯 Application Area
Application data not yet recorded.
Common Failures & Inspection Points
  • Area: Unzureichende Schichtdicke (DFT) = Keine Korrosionsschutz-Garantie
    Check: Measure with coating thickness gauge (gage) per SSPC-PA2. Example: Jotamastic 90 shall be 100 µm = passed; <75 µm = rework required. Statistical sampling: minimum 20 points/m².
  • Area: Schlechte Haftung (Adhesion-Versagen) = Abblätterung/Delaminierung
    Check: Cross-Hatch-Adhäsionstest (ASTM D3359) durchführen: 6mm Rasterabstände, Klebeband aufreißen. Bewertung: Level 0 = beste Haftung (0% Verlust). Level ≥3 = Schicht-Versagen → Nacharbeiten. Alternativ: Pull-off Test >5 MPa.
  • Area: Unvollständige Aushärtung = Weiche/klebrige Oberfläche, reduzierte Härte
    Check: Pencil hardness test (ASTM D3363) perform: guide pencil at 45° angle with pressure over surface. Expected for epoxy after 7 days: ≥H (hard). Observe test duration per TDS (typically 24–48h hard-dry, 7 days full cure).
  • Area: Surface preparation non-conforming (too rough/too smooth surface) = adhesion defect
    Check: Surface roughness inspect: ISO 8501-1 grade Sa 2½ (medium roughness) or white-metal. Surface roughness: 30–85 µm (ISO 8503-2, fine–medium). Visual + surface roughness gauge (profile gauge) use.
  • Area: Holiday/Pinhole-Defekte = lokale Korrosion trotz Beschichtung
    Check: Holiday detector (spark tester for >250 µm; low-volt sponge for <500 µm) guide over entire area systematically. Defects localize and mark with red marking → must be repaired before operation.
  • Area: PSPC/IMO non-conformity = tanks fail classification (ballast/cargo)
    Check: IMO PSPC certificate of coating system inspect (ballast tank coatings, COT = cargo oil tank). Salt spray test references (ASTM B117) ≥500 hours for ballast, ≥1000–2000h for heavy marine applications inspect. Certificates: ClassNK, Lloyd's Register.

Type-universal inspection/maintenance points for paint & coating systems (Jotun, Mega-Schwarm 2026-06). Per-model specs not auto-filled.

Jota BT Double Bottom
Position
Double Bottom
Pspc compliant
ja
Technical Specifications
Jotamastic 90 DFT
100 µm (Trockenfilm-Dicke)
Marathon IQ2 Maximum DFT
bis 500 µm, solidentfrei (98% Volumen)
Penguard Primer DFT
60–120 µm typisch
SeaQuantum Ultra VOC-Gehalt
Niedrig (<340 g/l); IMO AFS/CONF/26 konform
Haftungs-anforderung
≥5 MPa; ASTM D3359 Level 0–1
Salzsprühwiderstand (ASTM B117)
>1,000 hours typical; Marine Heavy-Duty 500–2,000 h
Product Lines
  • Jotamastic 90/87/80 (Epoxy Mastic Primer)
  • Marathon IQ2 (solventfrei Epoxy Topcoat)
  • Penguard Primer/HB/Universal (High-MW Epoxy Primer)
  • SeaQuantum Ultra III/S/SP (Antifouling Silyl-Acrylat)
  • SeaForce Shield/Active/Active Plus (Biozidbasierte Antifouling)
🎯 Application Area
Application data not yet recorded.
Common Failures & Inspection Points
  • Area: Unzureichende Schichtdicke (DFT) = Keine Korrosionsschutz-Garantie
    Check: Measure with coating thickness gauge (gage) per SSPC-PA2. Example: Jotamastic 90 shall be 100 µm = passed; <75 µm = rework required. Statistical sampling: minimum 20 points/m².
  • Area: Schlechte Haftung (Adhesion-Versagen) = Abblätterung/Delaminierung
    Check: Cross-Hatch-Adhäsionstest (ASTM D3359) durchführen: 6mm Rasterabstände, Klebeband aufreißen. Bewertung: Level 0 = beste Haftung (0% Verlust). Level ≥3 = Schicht-Versagen → Nacharbeiten. Alternativ: Pull-off Test >5 MPa.
  • Area: Unvollständige Aushärtung = Weiche/klebrige Oberfläche, reduzierte Härte
    Check: Pencil hardness test (ASTM D3363) perform: guide pencil at 45° angle with pressure over surface. Expected for epoxy after 7 days: ≥H (hard). Observe test duration per TDS (typically 24–48h hard-dry, 7 days full cure).
  • Area: Surface preparation non-conforming (too rough/too smooth surface) = adhesion defect
    Check: Surface roughness inspect: ISO 8501-1 grade Sa 2½ (medium roughness) or white-metal. Surface roughness: 30–85 µm (ISO 8503-2, fine–medium). Visual + surface roughness gauge (profile gauge) use.
  • Area: Holiday/Pinhole-Defekte = lokale Korrosion trotz Beschichtung
    Check: Holiday detector (spark tester for >250 µm; low-volt sponge for <500 µm) guide over entire area systematically. Defects localize and mark with red marking → must be repaired before operation.
  • Area: PSPC/IMO non-conformity = tanks fail classification (ballast/cargo)
    Check: IMO PSPC certificate of coating system inspect (ballast tank coatings, COT = cargo oil tank). Salt spray test references (ASTM B117) ≥500 hours for ballast, ≥1000–2000h for heavy marine applications inspect. Certificates: ClassNK, Lloyd's Register.

Type-universal inspection/maintenance points for paint & coating systems (Jotun, Mega-Schwarm 2026-06). Per-model specs not auto-filled.

Jota BT Side Tank
Position
Side Tank
Pspc compliant
ja
Technical Specifications
Jotamastic 90 DFT
100 µm (Trockenfilm-Dicke)
Marathon IQ2 Maximum DFT
bis 500 µm, solidentfrei (98% Volumen)
Penguard Primer DFT
60–120 µm typisch
SeaQuantum Ultra VOC-Gehalt
Niedrig (<340 g/l); IMO AFS/CONF/26 konform
Haftungs-anforderung
≥5 MPa; ASTM D3359 Level 0–1
Salzsprühwiderstand (ASTM B117)
>1,000 hours typical; Marine Heavy-Duty 500–2,000 h
Product Lines
  • Jotamastic 90/87/80 (Epoxy Mastic Primer)
  • Marathon IQ2 (solventfrei Epoxy Topcoat)
  • Penguard Primer/HB/Universal (High-MW Epoxy Primer)
  • SeaQuantum Ultra III/S/SP (Antifouling Silyl-Acrylat)
  • SeaForce Shield/Active/Active Plus (Biozidbasierte Antifouling)
🎯 Application Area
Application data not yet recorded.
Common Failures & Inspection Points
  • Area: Unzureichende Schichtdicke (DFT) = Keine Korrosionsschutz-Garantie
    Check: Measure with coating thickness gauge (gage) per SSPC-PA2. Example: Jotamastic 90 shall be 100 µm = passed; <75 µm = rework required. Statistical sampling: minimum 20 points/m².
  • Area: Schlechte Haftung (Adhesion-Versagen) = Abblätterung/Delaminierung
    Check: Cross-Hatch-Adhäsionstest (ASTM D3359) durchführen: 6mm Rasterabstände, Klebeband aufreißen. Bewertung: Level 0 = beste Haftung (0% Verlust). Level ≥3 = Schicht-Versagen → Nacharbeiten. Alternativ: Pull-off Test >5 MPa.
  • Area: Unvollständige Aushärtung = Weiche/klebrige Oberfläche, reduzierte Härte
    Check: Pencil hardness test (ASTM D3363) perform: guide pencil at 45° angle with pressure over surface. Expected for epoxy after 7 days: ≥H (hard). Observe test duration per TDS (typically 24–48h hard-dry, 7 days full cure).
  • Area: Surface preparation non-conforming (too rough/too smooth surface) = adhesion defect
    Check: Surface roughness inspect: ISO 8501-1 grade Sa 2½ (medium roughness) or white-metal. Surface roughness: 30–85 µm (ISO 8503-2, fine–medium). Visual + surface roughness gauge (profile gauge) use.
  • Area: Holiday/Pinhole-Defekte = lokale Korrosion trotz Beschichtung
    Check: Holiday detector (spark tester for >250 µm; low-volt sponge for <500 µm) guide over entire area systematically. Defects localize and mark with red marking → must be repaired before operation.
  • Area: PSPC/IMO non-conformity = tanks fail classification (ballast/cargo)
    Check: IMO PSPC certificate of coating system inspect (ballast tank coatings, COT = cargo oil tank). Salt spray test references (ASTM B117) ≥500 hours for ballast, ≥1000–2000h for heavy marine applications inspect. Certificates: ClassNK, Lloyd's Register.

Type-universal inspection/maintenance points for paint & coating systems (Jotun, Mega-Schwarm 2026-06). Per-model specs not auto-filled.

Jota BT Fore Peak
Position
Fore Peak
Pspc compliant
ja
Technical Specifications
Jotamastic 90 DFT
100 µm (Trockenfilm-Dicke)
Marathon IQ2 Maximum DFT
bis 500 µm, solidentfrei (98% Volumen)
Penguard Primer DFT
60–120 µm typisch
SeaQuantum Ultra VOC-Gehalt
Niedrig (<340 g/l); IMO AFS/CONF/26 konform
Haftungs-anforderung
≥5 MPa; ASTM D3359 Level 0–1
Salzsprühwiderstand (ASTM B117)
>1,000 hours typical; Marine Heavy-Duty 500–2,000 h
Product Lines
  • Jotamastic 90/87/80 (Epoxy Mastic Primer)
  • Marathon IQ2 (solventfrei Epoxy Topcoat)
  • Penguard Primer/HB/Universal (High-MW Epoxy Primer)
  • SeaQuantum Ultra III/S/SP (Antifouling Silyl-Acrylat)
  • SeaForce Shield/Active/Active Plus (Biozidbasierte Antifouling)
🎯 Application Area
Application data not yet recorded.
Common Failures & Inspection Points
  • Area: Unzureichende Schichtdicke (DFT) = Keine Korrosionsschutz-Garantie
    Check: Measure with coating thickness gauge (gage) per SSPC-PA2. Example: Jotamastic 90 shall be 100 µm = passed; <75 µm = rework required. Statistical sampling: minimum 20 points/m².
  • Area: Schlechte Haftung (Adhesion-Versagen) = Abblätterung/Delaminierung
    Check: Cross-Hatch-Adhäsionstest (ASTM D3359) durchführen: 6mm Rasterabstände, Klebeband aufreißen. Bewertung: Level 0 = beste Haftung (0% Verlust). Level ≥3 = Schicht-Versagen → Nacharbeiten. Alternativ: Pull-off Test >5 MPa.
  • Area: Unvollständige Aushärtung = Weiche/klebrige Oberfläche, reduzierte Härte
    Check: Pencil hardness test (ASTM D3363) perform: guide pencil at 45° angle with pressure over surface. Expected for epoxy after 7 days: ≥H (hard). Observe test duration per TDS (typically 24–48h hard-dry, 7 days full cure).
  • Area: Surface preparation non-conforming (too rough/too smooth surface) = adhesion defect
    Check: Surface roughness inspect: ISO 8501-1 grade Sa 2½ (medium roughness) or white-metal. Surface roughness: 30–85 µm (ISO 8503-2, fine–medium). Visual + surface roughness gauge (profile gauge) use.
  • Area: Holiday/Pinhole-Defekte = lokale Korrosion trotz Beschichtung
    Check: Holiday detector (spark tester for >250 µm; low-volt sponge for <500 µm) guide over entire area systematically. Defects localize and mark with red marking → must be repaired before operation.
  • Area: PSPC/IMO non-conformity = tanks fail classification (ballast/cargo)
    Check: IMO PSPC certificate of coating system inspect (ballast tank coatings, COT = cargo oil tank). Salt spray test references (ASTM B117) ≥500 hours for ballast, ≥1000–2000h for heavy marine applications inspect. Certificates: ClassNK, Lloyd's Register.

Type-universal inspection/maintenance points for paint & coating systems (Jotun, Mega-Schwarm 2026-06). Per-model specs not auto-filled.

Jota BT Aft Peak
Position
Aft Peak
Pspc compliant
ja
Technical Specifications
Jotamastic 90 DFT
100 µm (Trockenfilm-Dicke)
Marathon IQ2 Maximum DFT
bis 500 µm, solidentfrei (98% Volumen)
Penguard Primer DFT
60–120 µm typisch
SeaQuantum Ultra VOC-Gehalt
Niedrig (<340 g/l); IMO AFS/CONF/26 konform
Haftungs-anforderung
≥5 MPa; ASTM D3359 Level 0–1
Salzsprühwiderstand (ASTM B117)
>1,000 hours typical; Marine Heavy-Duty 500–2,000 h
Product Lines
  • Jotamastic 90/87/80 (Epoxy Mastic Primer)
  • Marathon IQ2 (solventfrei Epoxy Topcoat)
  • Penguard Primer/HB/Universal (High-MW Epoxy Primer)
  • SeaQuantum Ultra III/S/SP (Antifouling Silyl-Acrylat)
  • SeaForce Shield/Active/Active Plus (Biozidbasierte Antifouling)
🎯 Application Area
Application data not yet recorded.
Common Failures & Inspection Points
  • Area: Unzureichende Schichtdicke (DFT) = Keine Korrosionsschutz-Garantie
    Check: Measure with coating thickness gauge (gage) per SSPC-PA2. Example: Jotamastic 90 shall be 100 µm = passed; <75 µm = rework required. Statistical sampling: minimum 20 points/m².
  • Area: Schlechte Haftung (Adhesion-Versagen) = Abblätterung/Delaminierung
    Check: Cross-Hatch-Adhäsionstest (ASTM D3359) durchführen: 6mm Rasterabstände, Klebeband aufreißen. Bewertung: Level 0 = beste Haftung (0% Verlust). Level ≥3 = Schicht-Versagen → Nacharbeiten. Alternativ: Pull-off Test >5 MPa.
  • Area: Unvollständige Aushärtung = Weiche/klebrige Oberfläche, reduzierte Härte
    Check: Pencil hardness test (ASTM D3363) perform: guide pencil at 45° angle with pressure over surface. Expected for epoxy after 7 days: ≥H (hard). Observe test duration per TDS (typically 24–48h hard-dry, 7 days full cure).
  • Area: Surface preparation non-conforming (too rough/too smooth surface) = adhesion defect
    Check: Surface roughness inspect: ISO 8501-1 grade Sa 2½ (medium roughness) or white-metal. Surface roughness: 30–85 µm (ISO 8503-2, fine–medium). Visual + surface roughness gauge (profile gauge) use.
  • Area: Holiday/Pinhole-Defekte = lokale Korrosion trotz Beschichtung
    Check: Holiday detector (spark tester for >250 µm; low-volt sponge for <500 µm) guide over entire area systematically. Defects localize and mark with red marking → must be repaired before operation.
  • Area: PSPC/IMO non-conformity = tanks fail classification (ballast/cargo)
    Check: IMO PSPC certificate of coating system inspect (ballast tank coatings, COT = cargo oil tank). Salt spray test references (ASTM B117) ≥500 hours for ballast, ≥1000–2000h for heavy marine applications inspect. Certificates: ClassNK, Lloyd's Register.

Type-universal inspection/maintenance points for paint & coating systems (Jotun, Mega-Schwarm 2026-06). Per-model specs not auto-filled.

Jota BT Upper Wing
Position
Upper Wing
Pspc compliant
ja
Technical Specifications
Jotamastic 90 DFT
100 µm (Trockenfilm-Dicke)
Marathon IQ2 Maximum DFT
bis 500 µm, solidentfrei (98% Volumen)
Penguard Primer DFT
60–120 µm typisch
SeaQuantum Ultra VOC-Gehalt
Niedrig (<340 g/l); IMO AFS/CONF/26 konform
Haftungs-anforderung
≥5 MPa; ASTM D3359 Level 0–1
Salzsprühwiderstand (ASTM B117)
>1,000 hours typical; Marine Heavy-Duty 500–2,000 h
Product Lines
  • Jotamastic 90/87/80 (Epoxy Mastic Primer)
  • Marathon IQ2 (solventfrei Epoxy Topcoat)
  • Penguard Primer/HB/Universal (High-MW Epoxy Primer)
  • SeaQuantum Ultra III/S/SP (Antifouling Silyl-Acrylat)
  • SeaForce Shield/Active/Active Plus (Biozidbasierte Antifouling)
🎯 Application Area
Application data not yet recorded.
Common Failures & Inspection Points
  • Area: Unzureichende Schichtdicke (DFT) = Keine Korrosionsschutz-Garantie
    Check: Measure with coating thickness gauge (gage) per SSPC-PA2. Example: Jotamastic 90 shall be 100 µm = passed; <75 µm = rework required. Statistical sampling: minimum 20 points/m².
  • Area: Schlechte Haftung (Adhesion-Versagen) = Abblätterung/Delaminierung
    Check: Cross-Hatch-Adhäsionstest (ASTM D3359) durchführen: 6mm Rasterabstände, Klebeband aufreißen. Bewertung: Level 0 = beste Haftung (0% Verlust). Level ≥3 = Schicht-Versagen → Nacharbeiten. Alternativ: Pull-off Test >5 MPa.
  • Area: Unvollständige Aushärtung = Weiche/klebrige Oberfläche, reduzierte Härte
    Check: Pencil hardness test (ASTM D3363) perform: guide pencil at 45° angle with pressure over surface. Expected for epoxy after 7 days: ≥H (hard). Observe test duration per TDS (typically 24–48h hard-dry, 7 days full cure).
  • Area: Surface preparation non-conforming (too rough/too smooth surface) = adhesion defect
    Check: Surface roughness inspect: ISO 8501-1 grade Sa 2½ (medium roughness) or white-metal. Surface roughness: 30–85 µm (ISO 8503-2, fine–medium). Visual + surface roughness gauge (profile gauge) use.
  • Area: Holiday/Pinhole-Defekte = lokale Korrosion trotz Beschichtung
    Check: Holiday detector (spark tester for >250 µm; low-volt sponge for <500 µm) guide over entire area systematically. Defects localize and mark with red marking → must be repaired before operation.
  • Area: PSPC/IMO non-conformity = tanks fail classification (ballast/cargo)
    Check: IMO PSPC certificate of coating system inspect (ballast tank coatings, COT = cargo oil tank). Salt spray test references (ASTM B117) ≥500 hours for ballast, ≥1000–2000h for heavy marine applications inspect. Certificates: ClassNK, Lloyd's Register.

Type-universal inspection/maintenance points for paint & coating systems (Jotun, Mega-Schwarm 2026-06). Per-model specs not auto-filled.

Jotun Coal Tar Epoxy
Type
Coal Tar Epoxy
Technical Specifications
Jotamastic 90 DFT
100 µm (Trockenfilm-Dicke)
Marathon IQ2 Maximum DFT
bis 500 µm, solidentfrei (98% Volumen)
Penguard Primer DFT
60–120 µm typisch
SeaQuantum Ultra VOC-Gehalt
Niedrig (<340 g/l); IMO AFS/CONF/26 konform
Haftungs-anforderung
≥5 MPa; ASTM D3359 Level 0–1
Salzsprühwiderstand (ASTM B117)
>1,000 hours typical; Marine Heavy-Duty 500–2,000 h
Product Lines
  • Jotamastic 90/87/80 (Epoxy Mastic Primer)
  • Marathon IQ2 (solventfrei Epoxy Topcoat)
  • Penguard Primer/HB/Universal (High-MW Epoxy Primer)
  • SeaQuantum Ultra III/S/SP (Antifouling Silyl-Acrylat)
  • SeaForce Shield/Active/Active Plus (Biozidbasierte Antifouling)
🎯 Application Area
Application data not yet recorded.
Common Failures & Inspection Points
  • Area: Unzureichende Schichtdicke (DFT) = Keine Korrosionsschutz-Garantie
    Check: Measure with coating thickness gauge (gage) per SSPC-PA2. Example: Jotamastic 90 shall be 100 µm = passed; <75 µm = rework required. Statistical sampling: minimum 20 points/m².
  • Area: Schlechte Haftung (Adhesion-Versagen) = Abblätterung/Delaminierung
    Check: Cross-Hatch-Adhäsionstest (ASTM D3359) durchführen: 6mm Rasterabstände, Klebeband aufreißen. Bewertung: Level 0 = beste Haftung (0% Verlust). Level ≥3 = Schicht-Versagen → Nacharbeiten. Alternativ: Pull-off Test >5 MPa.
  • Area: Unvollständige Aushärtung = Weiche/klebrige Oberfläche, reduzierte Härte
    Check: Pencil hardness test (ASTM D3363) perform: guide pencil at 45° angle with pressure over surface. Expected for epoxy after 7 days: ≥H (hard). Observe test duration per TDS (typically 24–48h hard-dry, 7 days full cure).
  • Area: Surface preparation non-conforming (too rough/too smooth surface) = adhesion defect
    Check: Surface roughness inspect: ISO 8501-1 grade Sa 2½ (medium roughness) or white-metal. Surface roughness: 30–85 µm (ISO 8503-2, fine–medium). Visual + surface roughness gauge (profile gauge) use.
  • Area: Holiday/Pinhole-Defekte = lokale Korrosion trotz Beschichtung
    Check: Holiday detector (spark tester for >250 µm; low-volt sponge for <500 µm) guide over entire area systematically. Defects localize and mark with red marking → must be repaired before operation.
  • Area: PSPC/IMO non-conformity = tanks fail classification (ballast/cargo)
    Check: IMO PSPC certificate of coating system inspect (ballast tank coatings, COT = cargo oil tank). Salt spray test references (ASTM B117) ≥500 hours for ballast, ≥1000–2000h for heavy marine applications inspect. Certificates: ClassNK, Lloyd's Register.

Type-universal inspection/maintenance points for paint & coating systems (Jotun, Mega-Schwarm 2026-06). Per-model specs not auto-filled.

Jotun Potable Water Tank-C
Application
Potable Water Tank
Technical Specifications
Jotamastic 90 DFT
100 µm (Trockenfilm-Dicke)
Marathon IQ2 Maximum DFT
bis 500 µm, solidentfrei (98% Volumen)
Penguard Primer DFT
60–120 µm typisch
SeaQuantum Ultra VOC-Gehalt
Niedrig (<340 g/l); IMO AFS/CONF/26 konform
Haftungs-anforderung
≥5 MPa; ASTM D3359 Level 0–1
Salzsprühwiderstand (ASTM B117)
>1,000 hours typical; Marine Heavy-Duty 500–2,000 h
Product Lines
  • Jotamastic 90/87/80 (Epoxy Mastic Primer)
  • Marathon IQ2 (solventfrei Epoxy Topcoat)
  • Penguard Primer/HB/Universal (High-MW Epoxy Primer)
  • SeaQuantum Ultra III/S/SP (Antifouling Silyl-Acrylat)
  • SeaForce Shield/Active/Active Plus (Biozidbasierte Antifouling)
🎯 Application Area
Application data not yet recorded.
Common Failures & Inspection Points
  • Area: Unzureichende Schichtdicke (DFT) = Keine Korrosionsschutz-Garantie
    Check: Measure with coating thickness gauge (gage) per SSPC-PA2. Example: Jotamastic 90 shall be 100 µm = passed; <75 µm = rework required. Statistical sampling: minimum 20 points/m².
  • Area: Schlechte Haftung (Adhesion-Versagen) = Abblätterung/Delaminierung
    Check: Cross-Hatch-Adhäsionstest (ASTM D3359) durchführen: 6mm Rasterabstände, Klebeband aufreißen. Bewertung: Level 0 = beste Haftung (0% Verlust). Level ≥3 = Schicht-Versagen → Nacharbeiten. Alternativ: Pull-off Test >5 MPa.
  • Area: Unvollständige Aushärtung = Weiche/klebrige Oberfläche, reduzierte Härte
    Check: Pencil hardness test (ASTM D3363) perform: guide pencil at 45° angle with pressure over surface. Expected for epoxy after 7 days: ≥H (hard). Observe test duration per TDS (typically 24–48h hard-dry, 7 days full cure).
  • Area: Surface preparation non-conforming (too rough/too smooth surface) = adhesion defect
    Check: Surface roughness inspect: ISO 8501-1 grade Sa 2½ (medium roughness) or white-metal. Surface roughness: 30–85 µm (ISO 8503-2, fine–medium). Visual + surface roughness gauge (profile gauge) use.
  • Area: Holiday/Pinhole-Defekte = lokale Korrosion trotz Beschichtung
    Check: Holiday detector (spark tester for >250 µm; low-volt sponge for <500 µm) guide over entire area systematically. Defects localize and mark with red marking → must be repaired before operation.
  • Area: PSPC/IMO non-conformity = tanks fail classification (ballast/cargo)
    Check: IMO PSPC certificate of coating system inspect (ballast tank coatings, COT = cargo oil tank). Salt spray test references (ASTM B117) ≥500 hours for ballast, ≥1000–2000h for heavy marine applications inspect. Certificates: ClassNK, Lloyd's Register.

Type-universal inspection/maintenance points for paint & coating systems (Jotun, Mega-Schwarm 2026-06). Per-model specs not auto-filled.

Jotacote BT500 Ballast
Product Line
Jotacote
Coating Type
tank
Application Method
airless spray
Dft (µm)
300
Voc (g/l)
155
Overcoating Interval (h)
12
Technical Specifications
Jotamastic 90 DFT
100 µm (Trockenfilm-Dicke)
Marathon IQ2 Maximum DFT
bis 500 µm, solidentfrei (98% Volumen)
Penguard Primer DFT
60–120 µm typisch
SeaQuantum Ultra VOC-Gehalt
Niedrig (<340 g/l); IMO AFS/CONF/26 konform
Haftungs-anforderung
≥5 MPa; ASTM D3359 Level 0–1
Salzsprühwiderstand (ASTM B117)
>1,000 hours typical; Marine Heavy-Duty 500–2,000 h
Product Lines
  • Jotamastic 90/87/80 (Epoxy Mastic Primer)
  • Marathon IQ2 (solventfrei Epoxy Topcoat)
  • Penguard Primer/HB/Universal (High-MW Epoxy Primer)
  • SeaQuantum Ultra III/S/SP (Antifouling Silyl-Acrylat)
  • SeaForce Shield/Active/Active Plus (Biozidbasierte Antifouling)
🎯 Application Area
Application data not yet recorded.
Common Failures & Inspection Points
  • Area: Unzureichende Schichtdicke (DFT) = Keine Korrosionsschutz-Garantie
    Check: Measure with coating thickness gauge (gage) per SSPC-PA2. Example: Jotamastic 90 shall be 100 µm = passed; <75 µm = rework required. Statistical sampling: minimum 20 points/m².
  • Area: Schlechte Haftung (Adhesion-Versagen) = Abblätterung/Delaminierung
    Check: Cross-Hatch-Adhäsionstest (ASTM D3359) durchführen: 6mm Rasterabstände, Klebeband aufreißen. Bewertung: Level 0 = beste Haftung (0% Verlust). Level ≥3 = Schicht-Versagen → Nacharbeiten. Alternativ: Pull-off Test >5 MPa.
  • Area: Unvollständige Aushärtung = Weiche/klebrige Oberfläche, reduzierte Härte
    Check: Pencil hardness test (ASTM D3363) perform: guide pencil at 45° angle with pressure over surface. Expected for epoxy after 7 days: ≥H (hard). Observe test duration per TDS (typically 24–48h hard-dry, 7 days full cure).
  • Area: Surface preparation non-conforming (too rough/too smooth surface) = adhesion defect
    Check: Surface roughness inspect: ISO 8501-1 grade Sa 2½ (medium roughness) or white-metal. Surface roughness: 30–85 µm (ISO 8503-2, fine–medium). Visual + surface roughness gauge (profile gauge) use.
  • Area: Holiday/Pinhole-Defekte = lokale Korrosion trotz Beschichtung
    Check: Holiday detector (spark tester for >250 µm; low-volt sponge for <500 µm) guide over entire area systematically. Defects localize and mark with red marking → must be repaired before operation.
  • Area: PSPC/IMO non-conformity = tanks fail classification (ballast/cargo)
    Check: IMO PSPC certificate of coating system inspect (ballast tank coatings, COT = cargo oil tank). Salt spray test references (ASTM B117) ≥500 hours for ballast, ≥1000–2000h for heavy marine applications inspect. Certificates: ClassNK, Lloyd's Register.

Type-universal inspection/maintenance points for paint & coating systems (Jotun, Mega-Schwarm 2026-06). Per-model specs not auto-filled.

Jotacote PSPC Stripe Coat
Product Line
Jotacote PSPC
Coating Type
tank
Imo pspc compliant
ja
Coat layer
Stripe Coat
Application Method
airless spray
Dft (µm)
160
Voc (g/l)
190
Overcoating Interval (h)
8
Technical Specifications
Jotamastic 90 DFT
100 µm (Trockenfilm-Dicke)
Marathon IQ2 Maximum DFT
bis 500 µm, solidentfrei (98% Volumen)
Penguard Primer DFT
60–120 µm typisch
SeaQuantum Ultra VOC-Gehalt
Niedrig (<340 g/l); IMO AFS/CONF/26 konform
Haftungs-anforderung
≥5 MPa; ASTM D3359 Level 0–1
Salzsprühwiderstand (ASTM B117)
>1,000 hours typical; Marine Heavy-Duty 500–2,000 h
Product Lines
  • Jotamastic 90/87/80 (Epoxy Mastic Primer)
  • Marathon IQ2 (solventfrei Epoxy Topcoat)
  • Penguard Primer/HB/Universal (High-MW Epoxy Primer)
  • SeaQuantum Ultra III/S/SP (Antifouling Silyl-Acrylat)
  • SeaForce Shield/Active/Active Plus (Biozidbasierte Antifouling)
🎯 Application Area
Application data not yet recorded.
Common Failures & Inspection Points
  • Area: Unzureichende Schichtdicke (DFT) = Keine Korrosionsschutz-Garantie
    Check: Measure with coating thickness gauge (gage) per SSPC-PA2. Example: Jotamastic 90 shall be 100 µm = passed; <75 µm = rework required. Statistical sampling: minimum 20 points/m².
  • Area: Schlechte Haftung (Adhesion-Versagen) = Abblätterung/Delaminierung
    Check: Cross-Hatch-Adhäsionstest (ASTM D3359) durchführen: 6mm Rasterabstände, Klebeband aufreißen. Bewertung: Level 0 = beste Haftung (0% Verlust). Level ≥3 = Schicht-Versagen → Nacharbeiten. Alternativ: Pull-off Test >5 MPa.
  • Area: Unvollständige Aushärtung = Weiche/klebrige Oberfläche, reduzierte Härte
    Check: Pencil hardness test (ASTM D3363) perform: guide pencil at 45° angle with pressure over surface. Expected for epoxy after 7 days: ≥H (hard). Observe test duration per TDS (typically 24–48h hard-dry, 7 days full cure).
  • Area: Surface preparation non-conforming (too rough/too smooth surface) = adhesion defect
    Check: Surface roughness inspect: ISO 8501-1 grade Sa 2½ (medium roughness) or white-metal. Surface roughness: 30–85 µm (ISO 8503-2, fine–medium). Visual + surface roughness gauge (profile gauge) use.
  • Area: Holiday/Pinhole-Defekte = lokale Korrosion trotz Beschichtung
    Check: Holiday detector (spark tester for >250 µm; low-volt sponge for <500 µm) guide over entire area systematically. Defects localize and mark with red marking → must be repaired before operation.
  • Area: PSPC/IMO non-conformity = tanks fail classification (ballast/cargo)
    Check: IMO PSPC certificate of coating system inspect (ballast tank coatings, COT = cargo oil tank). Salt spray test references (ASTM B117) ≥500 hours for ballast, ≥1000–2000h for heavy marine applications inspect. Certificates: ClassNK, Lloyd's Register.

Type-universal inspection/maintenance points for paint & coating systems (Jotun, Mega-Schwarm 2026-06). Per-model specs not auto-filled.

Jotacote PSPC 1st Full Coat
Product Line
Jotacote PSPC
Coating Type
tank
Imo pspc compliant
ja
Coat layer
1st Full Coat
Application Method
airless spray
Dft (µm)
160
Voc (g/l)
190
Overcoating Interval (h)
8
Technical Specifications
Jotamastic 90 DFT
100 µm (Trockenfilm-Dicke)
Marathon IQ2 Maximum DFT
bis 500 µm, solidentfrei (98% Volumen)
Penguard Primer DFT
60–120 µm typisch
SeaQuantum Ultra VOC-Gehalt
Niedrig (<340 g/l); IMO AFS/CONF/26 konform
Haftungs-anforderung
≥5 MPa; ASTM D3359 Level 0–1
Salzsprühwiderstand (ASTM B117)
>1,000 hours typical; Marine Heavy-Duty 500–2,000 h
Product Lines
  • Jotamastic 90/87/80 (Epoxy Mastic Primer)
  • Marathon IQ2 (solventfrei Epoxy Topcoat)
  • Penguard Primer/HB/Universal (High-MW Epoxy Primer)
  • SeaQuantum Ultra III/S/SP (Antifouling Silyl-Acrylat)
  • SeaForce Shield/Active/Active Plus (Biozidbasierte Antifouling)
🎯 Application Area
Application data not yet recorded.
Common Failures & Inspection Points
  • Area: Unzureichende Schichtdicke (DFT) = Keine Korrosionsschutz-Garantie
    Check: Measure with coating thickness gauge (gage) per SSPC-PA2. Example: Jotamastic 90 shall be 100 µm = passed; <75 µm = rework required. Statistical sampling: minimum 20 points/m².
  • Area: Schlechte Haftung (Adhesion-Versagen) = Abblätterung/Delaminierung
    Check: Cross-Hatch-Adhäsionstest (ASTM D3359) durchführen: 6mm Rasterabstände, Klebeband aufreißen. Bewertung: Level 0 = beste Haftung (0% Verlust). Level ≥3 = Schicht-Versagen → Nacharbeiten. Alternativ: Pull-off Test >5 MPa.
  • Area: Unvollständige Aushärtung = Weiche/klebrige Oberfläche, reduzierte Härte
    Check: Pencil hardness test (ASTM D3363) perform: guide pencil at 45° angle with pressure over surface. Expected for epoxy after 7 days: ≥H (hard). Observe test duration per TDS (typically 24–48h hard-dry, 7 days full cure).
  • Area: Surface preparation non-conforming (too rough/too smooth surface) = adhesion defect
    Check: Surface roughness inspect: ISO 8501-1 grade Sa 2½ (medium roughness) or white-metal. Surface roughness: 30–85 µm (ISO 8503-2, fine–medium). Visual + surface roughness gauge (profile gauge) use.
  • Area: Holiday/Pinhole-Defekte = lokale Korrosion trotz Beschichtung
    Check: Holiday detector (spark tester for >250 µm; low-volt sponge for <500 µm) guide over entire area systematically. Defects localize and mark with red marking → must be repaired before operation.
  • Area: PSPC/IMO non-conformity = tanks fail classification (ballast/cargo)
    Check: IMO PSPC certificate of coating system inspect (ballast tank coatings, COT = cargo oil tank). Salt spray test references (ASTM B117) ≥500 hours for ballast, ≥1000–2000h for heavy marine applications inspect. Certificates: ClassNK, Lloyd's Register.

Type-universal inspection/maintenance points for paint & coating systems (Jotun, Mega-Schwarm 2026-06). Per-model specs not auto-filled.

Jotacote PSPC 2nd Full Coat
Product Line
Jotacote PSPC
Coating Type
tank
Imo pspc compliant
ja
Coat layer
2nd Full Coat
Application Method
airless spray
Dft (µm)
160
Voc (g/l)
190
Overcoating Interval (h)
8
Technical Specifications
Jotamastic 90 DFT
100 µm (Trockenfilm-Dicke)
Marathon IQ2 Maximum DFT
bis 500 µm, solidentfrei (98% Volumen)
Penguard Primer DFT
60–120 µm typisch
SeaQuantum Ultra VOC-Gehalt
Niedrig (<340 g/l); IMO AFS/CONF/26 konform
Haftungs-anforderung
≥5 MPa; ASTM D3359 Level 0–1
Salzsprühwiderstand (ASTM B117)
>1,000 hours typical; Marine Heavy-Duty 500–2,000 h
Product Lines
  • Jotamastic 90/87/80 (Epoxy Mastic Primer)
  • Marathon IQ2 (solventfrei Epoxy Topcoat)
  • Penguard Primer/HB/Universal (High-MW Epoxy Primer)
  • SeaQuantum Ultra III/S/SP (Antifouling Silyl-Acrylat)
  • SeaForce Shield/Active/Active Plus (Biozidbasierte Antifouling)
🎯 Application Area
Application data not yet recorded.
Common Failures & Inspection Points
  • Area: Unzureichende Schichtdicke (DFT) = Keine Korrosionsschutz-Garantie
    Check: Measure with coating thickness gauge (gage) per SSPC-PA2. Example: Jotamastic 90 shall be 100 µm = passed; <75 µm = rework required. Statistical sampling: minimum 20 points/m².
  • Area: Schlechte Haftung (Adhesion-Versagen) = Abblätterung/Delaminierung
    Check: Cross-Hatch-Adhäsionstest (ASTM D3359) durchführen: 6mm Rasterabstände, Klebeband aufreißen. Bewertung: Level 0 = beste Haftung (0% Verlust). Level ≥3 = Schicht-Versagen → Nacharbeiten. Alternativ: Pull-off Test >5 MPa.
  • Area: Unvollständige Aushärtung = Weiche/klebrige Oberfläche, reduzierte Härte
    Check: Pencil hardness test (ASTM D3363) perform: guide pencil at 45° angle with pressure over surface. Expected for epoxy after 7 days: ≥H (hard). Observe test duration per TDS (typically 24–48h hard-dry, 7 days full cure).
  • Area: Surface preparation non-conforming (too rough/too smooth surface) = adhesion defect
    Check: Surface roughness inspect: ISO 8501-1 grade Sa 2½ (medium roughness) or white-metal. Surface roughness: 30–85 µm (ISO 8503-2, fine–medium). Visual + surface roughness gauge (profile gauge) use.
  • Area: Holiday/Pinhole-Defekte = lokale Korrosion trotz Beschichtung
    Check: Holiday detector (spark tester for >250 µm; low-volt sponge for <500 µm) guide over entire area systematically. Defects localize and mark with red marking → must be repaired before operation.
  • Area: PSPC/IMO non-conformity = tanks fail classification (ballast/cargo)
    Check: IMO PSPC certificate of coating system inspect (ballast tank coatings, COT = cargo oil tank). Salt spray test references (ASTM B117) ≥500 hours for ballast, ≥1000–2000h for heavy marine applications inspect. Certificates: ClassNK, Lloyd's Register.

Type-universal inspection/maintenance points for paint & coating systems (Jotun, Mega-Schwarm 2026-06). Per-model specs not auto-filled.

Jotacote PSPC 500 IMO PSPC System
Product Line
Jotacote PSPC 500
Coating Type
tank
Imo pspc compliant
ja
Application Method
airless spray
Dft (µm)
320
Voc (g/l)
180
Technical Specifications
Jotamastic 90 DFT
100 µm (Trockenfilm-Dicke)
Marathon IQ2 Maximum DFT
bis 500 µm, solidentfrei (98% Volumen)
Penguard Primer DFT
60–120 µm typisch
SeaQuantum Ultra VOC-Gehalt
Niedrig (<340 g/l); IMO AFS/CONF/26 konform
Haftungs-anforderung
≥5 MPa; ASTM D3359 Level 0–1
Salzsprühwiderstand (ASTM B117)
>1,000 hours typical; Marine Heavy-Duty 500–2,000 h
Product Lines
  • Jotamastic 90/87/80 (Epoxy Mastic Primer)
  • Marathon IQ2 (solventfrei Epoxy Topcoat)
  • Penguard Primer/HB/Universal (High-MW Epoxy Primer)
  • SeaQuantum Ultra III/S/SP (Antifouling Silyl-Acrylat)
  • SeaForce Shield/Active/Active Plus (Biozidbasierte Antifouling)
🎯 Application Area
Application data not yet recorded.
Common Failures & Inspection Points
  • Area: Unzureichende Schichtdicke (DFT) = Keine Korrosionsschutz-Garantie
    Check: Measure with coating thickness gauge (gage) per SSPC-PA2. Example: Jotamastic 90 shall be 100 µm = passed; <75 µm = rework required. Statistical sampling: minimum 20 points/m².
  • Area: Schlechte Haftung (Adhesion-Versagen) = Abblätterung/Delaminierung
    Check: Cross-Hatch-Adhäsionstest (ASTM D3359) durchführen: 6mm Rasterabstände, Klebeband aufreißen. Bewertung: Level 0 = beste Haftung (0% Verlust). Level ≥3 = Schicht-Versagen → Nacharbeiten. Alternativ: Pull-off Test >5 MPa.
  • Area: Unvollständige Aushärtung = Weiche/klebrige Oberfläche, reduzierte Härte
    Check: Pencil hardness test (ASTM D3363) perform: guide pencil at 45° angle with pressure over surface. Expected for epoxy after 7 days: ≥H (hard). Observe test duration per TDS (typically 24–48h hard-dry, 7 days full cure).
  • Area: Surface preparation non-conforming (too rough/too smooth surface) = adhesion defect
    Check: Surface roughness inspect: ISO 8501-1 grade Sa 2½ (medium roughness) or white-metal. Surface roughness: 30–85 µm (ISO 8503-2, fine–medium). Visual + surface roughness gauge (profile gauge) use.
  • Area: Holiday/Pinhole-Defekte = lokale Korrosion trotz Beschichtung
    Check: Holiday detector (spark tester for >250 µm; low-volt sponge for <500 µm) guide over entire area systematically. Defects localize and mark with red marking → must be repaired before operation.
  • Area: PSPC/IMO non-conformity = tanks fail classification (ballast/cargo)
    Check: IMO PSPC certificate of coating system inspect (ballast tank coatings, COT = cargo oil tank). Salt spray test references (ASTM B117) ≥500 hours for ballast, ≥1000–2000h for heavy marine applications inspect. Certificates: ClassNK, Lloyd's Register.

Type-universal inspection/maintenance points for paint & coating systems (Jotun, Mega-Schwarm 2026-06). Per-model specs not auto-filled.

Jotacote Universal S120 (2 x 160 µm), Jotacote Universal S120 (1 x 320 µm) (one-coat system)
Per coating specification · Hull/Tank Protection Coating · Multi-purpose epoxy coating
Model Number
TAK00001YN
Technical Specifications
Jotamastic 90 DFT
100 µm (Trockenfilm-Dicke)
Marathon IQ2 Maximum DFT
bis 500 µm, solidentfrei (98% Volumen)
Penguard Primer DFT
60–120 µm typisch
SeaQuantum Ultra VOC-Gehalt
Niedrig (<340 g/l); IMO AFS/CONF/26 konform
Haftungs-anforderung
≥5 MPa; ASTM D3359 Level 0–1
Salzsprühwiderstand (ASTM B117)
>1,000 hours typical; Marine Heavy-Duty 500–2,000 h
Product Lines
  • Jotamastic 90/87/80 (Epoxy Mastic Primer)
  • Marathon IQ2 (solventfrei Epoxy Topcoat)
  • Penguard Primer/HB/Universal (High-MW Epoxy Primer)
  • SeaQuantum Ultra III/S/SP (Antifouling Silyl-Acrylat)
  • SeaForce Shield/Active/Active Plus (Biozidbasierte Antifouling)
🎯 Application Area
Vessel Types: TankerBulk CarrierContainerNewbuildFPSO
Technology: Multi-purpose epoxy coating
Application: Multipurpose epoxy coating of the Jotacote series by Jotun. Universal S120 — surface-tolerant for maintenance with reduced preparation. Applicable for ballast tanks, cargo holds, decks and external areas.
Selection Guide: Choose if: Versatile epoxy coating for new construction or docking. Avoid if: Maintenance without blasting — choose surface-tolerant (S120).
✔ Strengths
  • • Breites Anwendungsspektrum
  • • Bewaehrte Jotun-Qualitaet
  • • IMO-PSPC-konform
⚠ Weaknesses
  • • Erfordert gute Oberflaechenvorbereitung (min. Sa 2.5 fuer N-Varianten)
Common Failures & Inspection Points
  • Area: Unzureichende Schichtdicke (DFT) = Keine Korrosionsschutz-Garantie
    Check: Measure with coating thickness gauge (gage) per SSPC-PA2. Example: Jotamastic 90 shall be 100 µm = passed; <75 µm = rework required. Statistical sampling: minimum 20 points/m².
  • Area: Schlechte Haftung (Adhesion-Versagen) = Abblätterung/Delaminierung
    Check: Cross-Hatch-Adhäsionstest (ASTM D3359) durchführen: 6mm Rasterabstände, Klebeband aufreißen. Bewertung: Level 0 = beste Haftung (0% Verlust). Level ≥3 = Schicht-Versagen → Nacharbeiten. Alternativ: Pull-off Test >5 MPa.
  • Area: Unvollständige Aushärtung = Weiche/klebrige Oberfläche, reduzierte Härte
    Check: Pencil hardness test (ASTM D3363) perform: guide pencil at 45° angle with pressure over surface. Expected for epoxy after 7 days: ≥H (hard). Observe test duration per TDS (typically 24–48h hard-dry, 7 days full cure).
  • Area: Surface preparation non-conforming (too rough/too smooth surface) = adhesion defect
    Check: Surface roughness inspect: ISO 8501-1 grade Sa 2½ (medium roughness) or white-metal. Surface roughness: 30–85 µm (ISO 8503-2, fine–medium). Visual + surface roughness gauge (profile gauge) use.
  • Area: Holiday/Pinhole-Defekte = lokale Korrosion trotz Beschichtung
    Check: Holiday detector (spark tester for >250 µm; low-volt sponge for <500 µm) guide over entire area systematically. Defects localize and mark with red marking → must be repaired before operation.
  • Area: PSPC/IMO non-conformity = tanks fail classification (ballast/cargo)
    Check: IMO PSPC certificate of coating system inspect (ballast tank coatings, COT = cargo oil tank). Salt spray test references (ASTM B117) ≥500 hours for ballast, ≥1000–2000h for heavy marine applications inspect. Certificates: ClassNK, Lloyd's Register.

Type-universal inspection/maintenance points for paint & coating systems (Jotun, Mega-Schwarm 2026-06). Per-model specs not auto-filled.

Service: Coating inspection at docking. Anode check every 6 months. Touch-up work on damage immediately. Antifouling renewal at docking (every 5 years).
Spare Parts: Jotun A/S: Touch-Up Farbe in allen verwendeten Systemen an Bord vorhalten. Anoden per Dockungsbedarf.
Strengths
  • Breites Anwendungsspektrum
  • Bewaehrte Jotun-Qualitaet
  • IMO-PSPC-konform
Weaknesses
  • Erfordert gute Oberflaechenvorbereitung (min. Sa 2.5 fuer N-Varianten)
Jotacote Universal
Model Number
TAK000028Y
🎯 Application Area
Application data not yet recorded.
Jotaprime 510
Model Number
TAK00000EY
🎯 Application Area
Application data not yet recorded.
Penguard EXA II
Model Number
TAK000009B
🎯 Application Area
Application data not yet recorded.
Jotacote Universal N10
Model Number
TAK00002N1
🎯 Application Area
Application data not yet recorded.
SD ZINC 100QD + Jotaprime 510
Model Number
TAK00002MX
🎯 Application Area
Application data not yet recorded.
Jotacote Universal HF002 KR
Model Number
TAK00002KT
🎯 Application Area
Application data not yet recorded.
Jotacote Universal S120 (2 x 160 µm), Jotacote Universal S120 (1 x 320 µm) (one-coat system)
Model Number
TAK00001YR
🎯 Application Area
Application data not yet recorded.
Jotacote F60 6A + Jotacote Universal N10
Model Number
TAK00001YM
🎯 Application Area
Application data not yet recorded.
Penguard Universal
Model Number
TAK00001X1
🎯 Application Area
Application data not yet recorded.
Jotacote Universal HF002
Model Number
TAK00001WJ
🎯 Application Area
Application data not yet recorded.
Balloxy HB Light
Model Number
TAK00000SS
🎯 Application Area
Application data not yet recorded.

Hempel

17
Hempadur 15500
Type
Epoxy Ballast Tank
Impa
ja
Technical Specifications
DFT Standard (Hempadur PSPC)
320 µm total / 2×160 µm pro Schicht
DFT (Globic Antifouling)
100 µm Trockenfilm
Aushärtungszeit (Hempadur)
1–2 months full cure; 5–47 hours reworking window (temperature dependent)
Oberflächenrauhheit Anforderung
Sa 2.5 ISO 8501-1, Rugotest No. 3 or ISO roughness mean (G)
Haftungs-Mindestwert (Pull-off)
≥2,5 MPa allgemein; ≥5 MPa Immersion; ≥8 MPa >250 µm Gesamtdicke
Brennstoff-Ersparnis (Hempaguard X7)
21% über 90-Monats-Docking-Intervall (DNV validiert)
Aushärtungs-Temperaturkorrektionen
T ↓10°C → Aushärtungszeit ×2; T ↑10°C → ÷2
Product Lines
  • Hempadur (epoxy primers and intermediate coats)
  • Hempaguard (Silicon-Hydrogel Rumpfbeschichtung fuer Brennstoffeffizienz)
  • Globic (Antifouling mit Nano-Acrylat-Technologie)
🎯 Application Area
Application data not yet recorded.
Common Failures & Inspection Points
  • Area: Insufficient surface roughness or preparation before coating
    Check: Sa 2.5 (ISO 8501-1) surface roughness with Rugotest No. 3 or ISO comparator rough-medium inspect; visual inspection white surface
  • Area: Salt contamination reduces adhesion and causes blistering
    Check: Ion tester before/after blast cleaning (ISO 8502-1/2/3); limit value <50 mg/m² PSPC
  • Area: Dry film thickness <80% specification or >120% causes failure
    Check: DFT meter use; 90% measured values ≥256 µm at 320 µm nominal; edges with stripe coating; all values document
  • Area: Unvollständige Aushärtung → schlechte Schicht-Bindung, Wassereintritt, Blasenbildung
    Check: Cure time per manufacturer instructions (Hempadur 15570: 5-47 hours); temperature monitoring (T ↓10°C ×2); full cure 1-2 months before test
  • Area: Intercoat adhesion failure (<2.5 MPa) causes peeling and corrosion
    Check: ISO 4624 pull-off test after 1-2 months full cure; minimum adhesion ≥5 MPa immersion; ≥8 MPa >250 µm; 3 measurements/100 m²
  • Area: Oberflächenmängel (Blasen, Risse, Kratzer, ungleichmäßige Deckkraft) ermöglichen Wassereintritt
    Check: Visual 100% inspection for blisters/scratches/peeling; surface roughness global max. 125 µm inspect; finish standard per ship class

Type-universal inspection/maintenance points for paint & coating systems (Hempel, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Hempadur 15553
Type
Hi-Build Ballast
Dft (µm)
300
Technical Specifications
DFT Standard (Hempadur PSPC)
320 µm total / 2×160 µm pro Schicht
DFT (Globic Antifouling)
100 µm Trockenfilm
Aushärtungszeit (Hempadur)
1–2 months full cure; 5–47 hours reworking window (temperature dependent)
Oberflächenrauhheit Anforderung
Sa 2.5 ISO 8501-1, Rugotest No. 3 or ISO roughness mean (G)
Haftungs-Mindestwert (Pull-off)
≥2,5 MPa allgemein; ≥5 MPa Immersion; ≥8 MPa >250 µm Gesamtdicke
Brennstoff-Ersparnis (Hempaguard X7)
21% über 90-Monats-Docking-Intervall (DNV validiert)
Aushärtungs-Temperaturkorrektionen
T ↓10°C → Aushärtungszeit ×2; T ↑10°C → ÷2
Product Lines
  • Hempadur (epoxy primers and intermediate coats)
  • Hempaguard (Silicon-Hydrogel Rumpfbeschichtung fuer Brennstoffeffizienz)
  • Globic (Antifouling mit Nano-Acrylat-Technologie)
🎯 Application Area
Application data not yet recorded.
Common Failures & Inspection Points
  • Area: Insufficient surface roughness or preparation before coating
    Check: Sa 2.5 (ISO 8501-1) surface roughness with Rugotest No. 3 or ISO comparator rough-medium inspect; visual inspection white surface
  • Area: Salt contamination reduces adhesion and causes blistering
    Check: Ion tester before/after blast cleaning (ISO 8502-1/2/3); limit value <50 mg/m² PSPC
  • Area: Dry film thickness <80% specification or >120% causes failure
    Check: DFT meter use; 90% measured values ≥256 µm at 320 µm nominal; edges with stripe coating; all values document
  • Area: Unvollständige Aushärtung → schlechte Schicht-Bindung, Wassereintritt, Blasenbildung
    Check: Cure time per manufacturer instructions (Hempadur 15570: 5-47 hours); temperature monitoring (T ↓10°C ×2); full cure 1-2 months before test
  • Area: Intercoat adhesion failure (<2.5 MPa) causes peeling and corrosion
    Check: ISO 4624 pull-off test after 1-2 months full cure; minimum adhesion ≥5 MPa immersion; ≥8 MPa >250 µm; 3 measurements/100 m²
  • Area: Oberflächenmängel (Blasen, Risse, Kratzer, ungleichmäßige Deckkraft) ermöglichen Wassereintritt
    Check: Visual 100% inspection for blisters/scratches/peeling; surface roughness global max. 125 µm inspect; finish standard per ship class

Type-universal inspection/maintenance points for paint & coating systems (Hempel, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Hempadur 35560 BT
Type
Abrasion Resistant Ballast
Dft (µm)
300
Technical Specifications
DFT Standard (Hempadur PSPC)
320 µm total / 2×160 µm pro Schicht
DFT (Globic Antifouling)
100 µm Trockenfilm
Aushärtungszeit (Hempadur)
1–2 months full cure; 5–47 hours reworking window (temperature dependent)
Oberflächenrauhheit Anforderung
Sa 2.5 ISO 8501-1, Rugotest No. 3 or ISO roughness mean (G)
Haftungs-Mindestwert (Pull-off)
≥2,5 MPa allgemein; ≥5 MPa Immersion; ≥8 MPa >250 µm Gesamtdicke
Brennstoff-Ersparnis (Hempaguard X7)
21% über 90-Monats-Docking-Intervall (DNV validiert)
Aushärtungs-Temperaturkorrektionen
T ↓10°C → Aushärtungszeit ×2; T ↑10°C → ÷2
Product Lines
  • Hempadur (epoxy primers and intermediate coats)
  • Hempaguard (Silicon-Hydrogel Rumpfbeschichtung fuer Brennstoffeffizienz)
  • Globic (Antifouling mit Nano-Acrylat-Technologie)
🎯 Application Area
Application data not yet recorded.
Common Failures & Inspection Points
  • Area: Insufficient surface roughness or preparation before coating
    Check: Sa 2.5 (ISO 8501-1) surface roughness with Rugotest No. 3 or ISO comparator rough-medium inspect; visual inspection white surface
  • Area: Salt contamination reduces adhesion and causes blistering
    Check: Ion tester before/after blast cleaning (ISO 8502-1/2/3); limit value <50 mg/m² PSPC
  • Area: Dry film thickness <80% specification or >120% causes failure
    Check: DFT meter use; 90% measured values ≥256 µm at 320 µm nominal; edges with stripe coating; all values document
  • Area: Unvollständige Aushärtung → schlechte Schicht-Bindung, Wassereintritt, Blasenbildung
    Check: Cure time per manufacturer instructions (Hempadur 15570: 5-47 hours); temperature monitoring (T ↓10°C ×2); full cure 1-2 months before test
  • Area: Intercoat adhesion failure (<2.5 MPa) causes peeling and corrosion
    Check: ISO 4624 pull-off test after 1-2 months full cure; minimum adhesion ≥5 MPa immersion; ≥8 MPa >250 µm; 3 measurements/100 m²
  • Area: Oberflächenmängel (Blasen, Risse, Kratzer, ungleichmäßige Deckkraft) ermöglichen Wassereintritt
    Check: Visual 100% inspection for blisters/scratches/peeling; surface roughness global max. 125 µm inspect; finish standard per ship class

Type-universal inspection/maintenance points for paint & coating systems (Hempel, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Hempa BT Double Bottom
Position
Double Bottom
Pspc compliant
ja
Technical Specifications
DFT Standard (Hempadur PSPC)
320 µm total / 2×160 µm pro Schicht
DFT (Globic Antifouling)
100 µm Trockenfilm
Aushärtungszeit (Hempadur)
1–2 months full cure; 5–47 hours reworking window (temperature dependent)
Oberflächenrauhheit Anforderung
Sa 2.5 ISO 8501-1, Rugotest No. 3 or ISO roughness mean (G)
Haftungs-Mindestwert (Pull-off)
≥2,5 MPa allgemein; ≥5 MPa Immersion; ≥8 MPa >250 µm Gesamtdicke
Brennstoff-Ersparnis (Hempaguard X7)
21% über 90-Monats-Docking-Intervall (DNV validiert)
Aushärtungs-Temperaturkorrektionen
T ↓10°C → Aushärtungszeit ×2; T ↑10°C → ÷2
Product Lines
  • Hempadur (epoxy primers and intermediate coats)
  • Hempaguard (Silicon-Hydrogel Rumpfbeschichtung fuer Brennstoffeffizienz)
  • Globic (Antifouling mit Nano-Acrylat-Technologie)
🎯 Application Area
Application data not yet recorded.
Common Failures & Inspection Points
  • Area: Insufficient surface roughness or preparation before coating
    Check: Sa 2.5 (ISO 8501-1) surface roughness with Rugotest No. 3 or ISO comparator rough-medium inspect; visual inspection white surface
  • Area: Salt contamination reduces adhesion and causes blistering
    Check: Ion tester before/after blast cleaning (ISO 8502-1/2/3); limit value <50 mg/m² PSPC
  • Area: Dry film thickness <80% specification or >120% causes failure
    Check: DFT meter use; 90% measured values ≥256 µm at 320 µm nominal; edges with stripe coating; all values document
  • Area: Unvollständige Aushärtung → schlechte Schicht-Bindung, Wassereintritt, Blasenbildung
    Check: Cure time per manufacturer instructions (Hempadur 15570: 5-47 hours); temperature monitoring (T ↓10°C ×2); full cure 1-2 months before test
  • Area: Intercoat adhesion failure (<2.5 MPa) causes peeling and corrosion
    Check: ISO 4624 pull-off test after 1-2 months full cure; minimum adhesion ≥5 MPa immersion; ≥8 MPa >250 µm; 3 measurements/100 m²
  • Area: Oberflächenmängel (Blasen, Risse, Kratzer, ungleichmäßige Deckkraft) ermöglichen Wassereintritt
    Check: Visual 100% inspection for blisters/scratches/peeling; surface roughness global max. 125 µm inspect; finish standard per ship class

Type-universal inspection/maintenance points for paint & coating systems (Hempel, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Hempa BT Side Tank
Position
Side Tank
Pspc compliant
ja
Technical Specifications
DFT Standard (Hempadur PSPC)
320 µm total / 2×160 µm pro Schicht
DFT (Globic Antifouling)
100 µm Trockenfilm
Aushärtungszeit (Hempadur)
1–2 months full cure; 5–47 hours reworking window (temperature dependent)
Oberflächenrauhheit Anforderung
Sa 2.5 ISO 8501-1, Rugotest No. 3 or ISO roughness mean (G)
Haftungs-Mindestwert (Pull-off)
≥2,5 MPa allgemein; ≥5 MPa Immersion; ≥8 MPa >250 µm Gesamtdicke
Brennstoff-Ersparnis (Hempaguard X7)
21% über 90-Monats-Docking-Intervall (DNV validiert)
Aushärtungs-Temperaturkorrektionen
T ↓10°C → Aushärtungszeit ×2; T ↑10°C → ÷2
Product Lines
  • Hempadur (epoxy primers and intermediate coats)
  • Hempaguard (Silicon-Hydrogel Rumpfbeschichtung fuer Brennstoffeffizienz)
  • Globic (Antifouling mit Nano-Acrylat-Technologie)
🎯 Application Area
Application data not yet recorded.
Common Failures & Inspection Points
  • Area: Insufficient surface roughness or preparation before coating
    Check: Sa 2.5 (ISO 8501-1) surface roughness with Rugotest No. 3 or ISO comparator rough-medium inspect; visual inspection white surface
  • Area: Salt contamination reduces adhesion and causes blistering
    Check: Ion tester before/after blast cleaning (ISO 8502-1/2/3); limit value <50 mg/m² PSPC
  • Area: Dry film thickness <80% specification or >120% causes failure
    Check: DFT meter use; 90% measured values ≥256 µm at 320 µm nominal; edges with stripe coating; all values document
  • Area: Unvollständige Aushärtung → schlechte Schicht-Bindung, Wassereintritt, Blasenbildung
    Check: Cure time per manufacturer instructions (Hempadur 15570: 5-47 hours); temperature monitoring (T ↓10°C ×2); full cure 1-2 months before test
  • Area: Intercoat adhesion failure (<2.5 MPa) causes peeling and corrosion
    Check: ISO 4624 pull-off test after 1-2 months full cure; minimum adhesion ≥5 MPa immersion; ≥8 MPa >250 µm; 3 measurements/100 m²
  • Area: Oberflächenmängel (Blasen, Risse, Kratzer, ungleichmäßige Deckkraft) ermöglichen Wassereintritt
    Check: Visual 100% inspection for blisters/scratches/peeling; surface roughness global max. 125 µm inspect; finish standard per ship class

Type-universal inspection/maintenance points for paint & coating systems (Hempel, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Hempa BT Fore Peak
Position
Fore Peak
Pspc compliant
ja
Technical Specifications
DFT Standard (Hempadur PSPC)
320 µm total / 2×160 µm pro Schicht
DFT (Globic Antifouling)
100 µm Trockenfilm
Aushärtungszeit (Hempadur)
1–2 months full cure; 5–47 hours reworking window (temperature dependent)
Oberflächenrauhheit Anforderung
Sa 2.5 ISO 8501-1, Rugotest No. 3 or ISO roughness mean (G)
Haftungs-Mindestwert (Pull-off)
≥2,5 MPa allgemein; ≥5 MPa Immersion; ≥8 MPa >250 µm Gesamtdicke
Brennstoff-Ersparnis (Hempaguard X7)
21% über 90-Monats-Docking-Intervall (DNV validiert)
Aushärtungs-Temperaturkorrektionen
T ↓10°C → Aushärtungszeit ×2; T ↑10°C → ÷2
Product Lines
  • Hempadur (epoxy primers and intermediate coats)
  • Hempaguard (Silicon-Hydrogel Rumpfbeschichtung fuer Brennstoffeffizienz)
  • Globic (Antifouling mit Nano-Acrylat-Technologie)
🎯 Application Area
Application data not yet recorded.
Common Failures & Inspection Points
  • Area: Insufficient surface roughness or preparation before coating
    Check: Sa 2.5 (ISO 8501-1) surface roughness with Rugotest No. 3 or ISO comparator rough-medium inspect; visual inspection white surface
  • Area: Salt contamination reduces adhesion and causes blistering
    Check: Ion tester before/after blast cleaning (ISO 8502-1/2/3); limit value <50 mg/m² PSPC
  • Area: Dry film thickness <80% specification or >120% causes failure
    Check: DFT meter use; 90% measured values ≥256 µm at 320 µm nominal; edges with stripe coating; all values document
  • Area: Unvollständige Aushärtung → schlechte Schicht-Bindung, Wassereintritt, Blasenbildung
    Check: Cure time per manufacturer instructions (Hempadur 15570: 5-47 hours); temperature monitoring (T ↓10°C ×2); full cure 1-2 months before test
  • Area: Intercoat adhesion failure (<2.5 MPa) causes peeling and corrosion
    Check: ISO 4624 pull-off test after 1-2 months full cure; minimum adhesion ≥5 MPa immersion; ≥8 MPa >250 µm; 3 measurements/100 m²
  • Area: Oberflächenmängel (Blasen, Risse, Kratzer, ungleichmäßige Deckkraft) ermöglichen Wassereintritt
    Check: Visual 100% inspection for blisters/scratches/peeling; surface roughness global max. 125 µm inspect; finish standard per ship class

Type-universal inspection/maintenance points for paint & coating systems (Hempel, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Hempa BT Aft Peak
Position
Aft Peak
Pspc compliant
ja
Technical Specifications
DFT Standard (Hempadur PSPC)
320 µm total / 2×160 µm pro Schicht
DFT (Globic Antifouling)
100 µm Trockenfilm
Aushärtungszeit (Hempadur)
1–2 months full cure; 5–47 hours reworking window (temperature dependent)
Oberflächenrauhheit Anforderung
Sa 2.5 ISO 8501-1, Rugotest No. 3 or ISO roughness mean (G)
Haftungs-Mindestwert (Pull-off)
≥2,5 MPa allgemein; ≥5 MPa Immersion; ≥8 MPa >250 µm Gesamtdicke
Brennstoff-Ersparnis (Hempaguard X7)
21% über 90-Monats-Docking-Intervall (DNV validiert)
Aushärtungs-Temperaturkorrektionen
T ↓10°C → Aushärtungszeit ×2; T ↑10°C → ÷2
Product Lines
  • Hempadur (epoxy primers and intermediate coats)
  • Hempaguard (Silicon-Hydrogel Rumpfbeschichtung fuer Brennstoffeffizienz)
  • Globic (Antifouling mit Nano-Acrylat-Technologie)
🎯 Application Area
Application data not yet recorded.
Common Failures & Inspection Points
  • Area: Insufficient surface roughness or preparation before coating
    Check: Sa 2.5 (ISO 8501-1) surface roughness with Rugotest No. 3 or ISO comparator rough-medium inspect; visual inspection white surface
  • Area: Salt contamination reduces adhesion and causes blistering
    Check: Ion tester before/after blast cleaning (ISO 8502-1/2/3); limit value <50 mg/m² PSPC
  • Area: Dry film thickness <80% specification or >120% causes failure
    Check: DFT meter use; 90% measured values ≥256 µm at 320 µm nominal; edges with stripe coating; all values document
  • Area: Unvollständige Aushärtung → schlechte Schicht-Bindung, Wassereintritt, Blasenbildung
    Check: Cure time per manufacturer instructions (Hempadur 15570: 5-47 hours); temperature monitoring (T ↓10°C ×2); full cure 1-2 months before test
  • Area: Intercoat adhesion failure (<2.5 MPa) causes peeling and corrosion
    Check: ISO 4624 pull-off test after 1-2 months full cure; minimum adhesion ≥5 MPa immersion; ≥8 MPa >250 µm; 3 measurements/100 m²
  • Area: Oberflächenmängel (Blasen, Risse, Kratzer, ungleichmäßige Deckkraft) ermöglichen Wassereintritt
    Check: Visual 100% inspection for blisters/scratches/peeling; surface roughness global max. 125 µm inspect; finish standard per ship class

Type-universal inspection/maintenance points for paint & coating systems (Hempel, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Hempa BT Upper Wing
Position
Upper Wing
Pspc compliant
ja
Technical Specifications
DFT Standard (Hempadur PSPC)
320 µm total / 2×160 µm pro Schicht
DFT (Globic Antifouling)
100 µm Trockenfilm
Aushärtungszeit (Hempadur)
1–2 months full cure; 5–47 hours reworking window (temperature dependent)
Oberflächenrauhheit Anforderung
Sa 2.5 ISO 8501-1, Rugotest No. 3 or ISO roughness mean (G)
Haftungs-Mindestwert (Pull-off)
≥2,5 MPa allgemein; ≥5 MPa Immersion; ≥8 MPa >250 µm Gesamtdicke
Brennstoff-Ersparnis (Hempaguard X7)
21% über 90-Monats-Docking-Intervall (DNV validiert)
Aushärtungs-Temperaturkorrektionen
T ↓10°C → Aushärtungszeit ×2; T ↑10°C → ÷2
Product Lines
  • Hempadur (epoxy primers and intermediate coats)
  • Hempaguard (Silicon-Hydrogel Rumpfbeschichtung fuer Brennstoffeffizienz)
  • Globic (Antifouling mit Nano-Acrylat-Technologie)
🎯 Application Area
Application data not yet recorded.
Common Failures & Inspection Points
  • Area: Insufficient surface roughness or preparation before coating
    Check: Sa 2.5 (ISO 8501-1) surface roughness with Rugotest No. 3 or ISO comparator rough-medium inspect; visual inspection white surface
  • Area: Salt contamination reduces adhesion and causes blistering
    Check: Ion tester before/after blast cleaning (ISO 8502-1/2/3); limit value <50 mg/m² PSPC
  • Area: Dry film thickness <80% specification or >120% causes failure
    Check: DFT meter use; 90% measured values ≥256 µm at 320 µm nominal; edges with stripe coating; all values document
  • Area: Unvollständige Aushärtung → schlechte Schicht-Bindung, Wassereintritt, Blasenbildung
    Check: Cure time per manufacturer instructions (Hempadur 15570: 5-47 hours); temperature monitoring (T ↓10°C ×2); full cure 1-2 months before test
  • Area: Intercoat adhesion failure (<2.5 MPa) causes peeling and corrosion
    Check: ISO 4624 pull-off test after 1-2 months full cure; minimum adhesion ≥5 MPa immersion; ≥8 MPa >250 µm; 3 measurements/100 m²
  • Area: Oberflächenmängel (Blasen, Risse, Kratzer, ungleichmäßige Deckkraft) ermöglichen Wassereintritt
    Check: Visual 100% inspection for blisters/scratches/peeling; surface roughness global max. 125 µm inspect; finish standard per ship class

Type-universal inspection/maintenance points for paint & coating systems (Hempel, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Hempel Coal Tar Epoxy
Type
Coal Tar Epoxy
Technical Specifications
DFT Standard (Hempadur PSPC)
320 µm total / 2×160 µm pro Schicht
DFT (Globic Antifouling)
100 µm Trockenfilm
Aushärtungszeit (Hempadur)
1–2 months full cure; 5–47 hours reworking window (temperature dependent)
Oberflächenrauhheit Anforderung
Sa 2.5 ISO 8501-1, Rugotest No. 3 or ISO roughness mean (G)
Haftungs-Mindestwert (Pull-off)
≥2,5 MPa allgemein; ≥5 MPa Immersion; ≥8 MPa >250 µm Gesamtdicke
Brennstoff-Ersparnis (Hempaguard X7)
21% über 90-Monats-Docking-Intervall (DNV validiert)
Aushärtungs-Temperaturkorrektionen
T ↓10°C → Aushärtungszeit ×2; T ↑10°C → ÷2
Product Lines
  • Hempadur (epoxy primers and intermediate coats)
  • Hempaguard (Silicon-Hydrogel Rumpfbeschichtung fuer Brennstoffeffizienz)
  • Globic (Antifouling mit Nano-Acrylat-Technologie)
🎯 Application Area
Application data not yet recorded.
Common Failures & Inspection Points
  • Area: Insufficient surface roughness or preparation before coating
    Check: Sa 2.5 (ISO 8501-1) surface roughness with Rugotest No. 3 or ISO comparator rough-medium inspect; visual inspection white surface
  • Area: Salt contamination reduces adhesion and causes blistering
    Check: Ion tester before/after blast cleaning (ISO 8502-1/2/3); limit value <50 mg/m² PSPC
  • Area: Dry film thickness <80% specification or >120% causes failure
    Check: DFT meter use; 90% measured values ≥256 µm at 320 µm nominal; edges with stripe coating; all values document
  • Area: Unvollständige Aushärtung → schlechte Schicht-Bindung, Wassereintritt, Blasenbildung
    Check: Cure time per manufacturer instructions (Hempadur 15570: 5-47 hours); temperature monitoring (T ↓10°C ×2); full cure 1-2 months before test
  • Area: Intercoat adhesion failure (<2.5 MPa) causes peeling and corrosion
    Check: ISO 4624 pull-off test after 1-2 months full cure; minimum adhesion ≥5 MPa immersion; ≥8 MPa >250 µm; 3 measurements/100 m²
  • Area: Oberflächenmängel (Blasen, Risse, Kratzer, ungleichmäßige Deckkraft) ermöglichen Wassereintritt
    Check: Visual 100% inspection for blisters/scratches/peeling; surface roughness global max. 125 µm inspect; finish standard per ship class

Type-universal inspection/maintenance points for paint & coating systems (Hempel, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Hempel Potable Water Tank-C
Application
Potable Water Tank
Technical Specifications
DFT Standard (Hempadur PSPC)
320 µm total / 2×160 µm pro Schicht
DFT (Globic Antifouling)
100 µm Trockenfilm
Aushärtungszeit (Hempadur)
1–2 months full cure; 5–47 hours reworking window (temperature dependent)
Oberflächenrauhheit Anforderung
Sa 2.5 ISO 8501-1, Rugotest No. 3 or ISO roughness mean (G)
Haftungs-Mindestwert (Pull-off)
≥2,5 MPa allgemein; ≥5 MPa Immersion; ≥8 MPa >250 µm Gesamtdicke
Brennstoff-Ersparnis (Hempaguard X7)
21% über 90-Monats-Docking-Intervall (DNV validiert)
Aushärtungs-Temperaturkorrektionen
T ↓10°C → Aushärtungszeit ×2; T ↑10°C → ÷2
Product Lines
  • Hempadur (epoxy primers and intermediate coats)
  • Hempaguard (Silicon-Hydrogel Rumpfbeschichtung fuer Brennstoffeffizienz)
  • Globic (Antifouling mit Nano-Acrylat-Technologie)
🎯 Application Area
Application data not yet recorded.
Common Failures & Inspection Points
  • Area: Insufficient surface roughness or preparation before coating
    Check: Sa 2.5 (ISO 8501-1) surface roughness with Rugotest No. 3 or ISO comparator rough-medium inspect; visual inspection white surface
  • Area: Salt contamination reduces adhesion and causes blistering
    Check: Ion tester before/after blast cleaning (ISO 8502-1/2/3); limit value <50 mg/m² PSPC
  • Area: Dry film thickness <80% specification or >120% causes failure
    Check: DFT meter use; 90% measured values ≥256 µm at 320 µm nominal; edges with stripe coating; all values document
  • Area: Unvollständige Aushärtung → schlechte Schicht-Bindung, Wassereintritt, Blasenbildung
    Check: Cure time per manufacturer instructions (Hempadur 15570: 5-47 hours); temperature monitoring (T ↓10°C ×2); full cure 1-2 months before test
  • Area: Intercoat adhesion failure (<2.5 MPa) causes peeling and corrosion
    Check: ISO 4624 pull-off test after 1-2 months full cure; minimum adhesion ≥5 MPa immersion; ≥8 MPa >250 µm; 3 measurements/100 m²
  • Area: Oberflächenmängel (Blasen, Risse, Kratzer, ungleichmäßige Deckkraft) ermöglichen Wassereintritt
    Check: Visual 100% inspection for blisters/scratches/peeling; surface roughness global max. 125 µm inspect; finish standard per ship class

Type-universal inspection/maintenance points for paint & coating systems (Hempel, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Hempadur 15560 BT
Product Line
Hempadur
Coating Type
tank
Application Method
airless spray
Dft (µm)
200
Voc (g/l)
195
Overcoating Interval (h)
8
Technical Specifications
DFT Standard (Hempadur PSPC)
320 µm total / 2×160 µm pro Schicht
DFT (Globic Antifouling)
100 µm Trockenfilm
Aushärtungszeit (Hempadur)
1–2 months full cure; 5–47 hours reworking window (temperature dependent)
Oberflächenrauhheit Anforderung
Sa 2.5 ISO 8501-1, Rugotest No. 3 or ISO roughness mean (G)
Haftungs-Mindestwert (Pull-off)
≥2,5 MPa allgemein; ≥5 MPa Immersion; ≥8 MPa >250 µm Gesamtdicke
Brennstoff-Ersparnis (Hempaguard X7)
21% über 90-Monats-Docking-Intervall (DNV validiert)
Aushärtungs-Temperaturkorrektionen
T ↓10°C → Aushärtungszeit ×2; T ↑10°C → ÷2
Product Lines
  • Hempadur (epoxy primers and intermediate coats)
  • Hempaguard (Silicon-Hydrogel Rumpfbeschichtung fuer Brennstoffeffizienz)
  • Globic (Antifouling mit Nano-Acrylat-Technologie)
🎯 Application Area
Application data not yet recorded.
Common Failures & Inspection Points
  • Area: Insufficient surface roughness or preparation before coating
    Check: Sa 2.5 (ISO 8501-1) surface roughness with Rugotest No. 3 or ISO comparator rough-medium inspect; visual inspection white surface
  • Area: Salt contamination reduces adhesion and causes blistering
    Check: Ion tester before/after blast cleaning (ISO 8502-1/2/3); limit value <50 mg/m² PSPC
  • Area: Dry film thickness <80% specification or >120% causes failure
    Check: DFT meter use; 90% measured values ≥256 µm at 320 µm nominal; edges with stripe coating; all values document
  • Area: Unvollständige Aushärtung → schlechte Schicht-Bindung, Wassereintritt, Blasenbildung
    Check: Cure time per manufacturer instructions (Hempadur 15570: 5-47 hours); temperature monitoring (T ↓10°C ×2); full cure 1-2 months before test
  • Area: Intercoat adhesion failure (<2.5 MPa) causes peeling and corrosion
    Check: ISO 4624 pull-off test after 1-2 months full cure; minimum adhesion ≥5 MPa immersion; ≥8 MPa >250 µm; 3 measurements/100 m²
  • Area: Oberflächenmängel (Blasen, Risse, Kratzer, ungleichmäßige Deckkraft) ermöglichen Wassereintritt
    Check: Visual 100% inspection for blisters/scratches/peeling; surface roughness global max. 125 µm inspect; finish standard per ship class

Type-universal inspection/maintenance points for paint & coating systems (Hempel, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Hempadur 47182 BT
Product Line
Hempadur
Coating Type
tank
Application Method
airless spray
Dft (µm)
350
Voc (g/l)
155
Overcoating Interval (h)
12
Technical Specifications
DFT Standard (Hempadur PSPC)
320 µm total / 2×160 µm pro Schicht
DFT (Globic Antifouling)
100 µm Trockenfilm
Aushärtungszeit (Hempadur)
1–2 months full cure; 5–47 hours reworking window (temperature dependent)
Oberflächenrauhheit Anforderung
Sa 2.5 ISO 8501-1, Rugotest No. 3 or ISO roughness mean (G)
Haftungs-Mindestwert (Pull-off)
≥2,5 MPa allgemein; ≥5 MPa Immersion; ≥8 MPa >250 µm Gesamtdicke
Brennstoff-Ersparnis (Hempaguard X7)
21% über 90-Monats-Docking-Intervall (DNV validiert)
Aushärtungs-Temperaturkorrektionen
T ↓10°C → Aushärtungszeit ×2; T ↑10°C → ÷2
Product Lines
  • Hempadur (epoxy primers and intermediate coats)
  • Hempaguard (Silicon-Hydrogel Rumpfbeschichtung fuer Brennstoffeffizienz)
  • Globic (Antifouling mit Nano-Acrylat-Technologie)
🎯 Application Area
Application data not yet recorded.
Common Failures & Inspection Points
  • Area: Insufficient surface roughness or preparation before coating
    Check: Sa 2.5 (ISO 8501-1) surface roughness with Rugotest No. 3 or ISO comparator rough-medium inspect; visual inspection white surface
  • Area: Salt contamination reduces adhesion and causes blistering
    Check: Ion tester before/after blast cleaning (ISO 8502-1/2/3); limit value <50 mg/m² PSPC
  • Area: Dry film thickness <80% specification or >120% causes failure
    Check: DFT meter use; 90% measured values ≥256 µm at 320 µm nominal; edges with stripe coating; all values document
  • Area: Unvollständige Aushärtung → schlechte Schicht-Bindung, Wassereintritt, Blasenbildung
    Check: Cure time per manufacturer instructions (Hempadur 15570: 5-47 hours); temperature monitoring (T ↓10°C ×2); full cure 1-2 months before test
  • Area: Intercoat adhesion failure (<2.5 MPa) causes peeling and corrosion
    Check: ISO 4624 pull-off test after 1-2 months full cure; minimum adhesion ≥5 MPa immersion; ≥8 MPa >250 µm; 3 measurements/100 m²
  • Area: Oberflächenmängel (Blasen, Risse, Kratzer, ungleichmäßige Deckkraft) ermöglichen Wassereintritt
    Check: Visual 100% inspection for blisters/scratches/peeling; surface roughness global max. 125 µm inspect; finish standard per ship class

Type-universal inspection/maintenance points for paint & coating systems (Hempel, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Hempadur PSPC Stripe Coat
Product Line
Hempadur PSPC
Coating Type
tank
Imo pspc compliant
ja
Coat layer
Stripe Coat
Application Method
airless spray
Dft (µm)
160
Voc (g/l)
190
Overcoating Interval (h)
8
Technical Specifications
DFT Standard (Hempadur PSPC)
320 µm total / 2×160 µm pro Schicht
DFT (Globic Antifouling)
100 µm Trockenfilm
Aushärtungszeit (Hempadur)
1–2 months full cure; 5–47 hours reworking window (temperature dependent)
Oberflächenrauhheit Anforderung
Sa 2.5 ISO 8501-1, Rugotest No. 3 or ISO roughness mean (G)
Haftungs-Mindestwert (Pull-off)
≥2,5 MPa allgemein; ≥5 MPa Immersion; ≥8 MPa >250 µm Gesamtdicke
Brennstoff-Ersparnis (Hempaguard X7)
21% über 90-Monats-Docking-Intervall (DNV validiert)
Aushärtungs-Temperaturkorrektionen
T ↓10°C → Aushärtungszeit ×2; T ↑10°C → ÷2
Product Lines
  • Hempadur (epoxy primers and intermediate coats)
  • Hempaguard (Silicon-Hydrogel Rumpfbeschichtung fuer Brennstoffeffizienz)
  • Globic (Antifouling mit Nano-Acrylat-Technologie)
🎯 Application Area
Application data not yet recorded.
Common Failures & Inspection Points
  • Area: Insufficient surface roughness or preparation before coating
    Check: Sa 2.5 (ISO 8501-1) surface roughness with Rugotest No. 3 or ISO comparator rough-medium inspect; visual inspection white surface
  • Area: Salt contamination reduces adhesion and causes blistering
    Check: Ion tester before/after blast cleaning (ISO 8502-1/2/3); limit value <50 mg/m² PSPC
  • Area: Dry film thickness <80% specification or >120% causes failure
    Check: DFT meter use; 90% measured values ≥256 µm at 320 µm nominal; edges with stripe coating; all values document
  • Area: Unvollständige Aushärtung → schlechte Schicht-Bindung, Wassereintritt, Blasenbildung
    Check: Cure time per manufacturer instructions (Hempadur 15570: 5-47 hours); temperature monitoring (T ↓10°C ×2); full cure 1-2 months before test
  • Area: Intercoat adhesion failure (<2.5 MPa) causes peeling and corrosion
    Check: ISO 4624 pull-off test after 1-2 months full cure; minimum adhesion ≥5 MPa immersion; ≥8 MPa >250 µm; 3 measurements/100 m²
  • Area: Oberflächenmängel (Blasen, Risse, Kratzer, ungleichmäßige Deckkraft) ermöglichen Wassereintritt
    Check: Visual 100% inspection for blisters/scratches/peeling; surface roughness global max. 125 µm inspect; finish standard per ship class

Type-universal inspection/maintenance points for paint & coating systems (Hempel, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Hempadur PSPC 1st Full Coat
Product Line
Hempadur PSPC
Coating Type
tank
Imo pspc compliant
ja
Coat layer
1st Full Coat
Application Method
airless spray
Dft (µm)
160
Voc (g/l)
190
Overcoating Interval (h)
8
Technical Specifications
DFT Standard (Hempadur PSPC)
320 µm total / 2×160 µm pro Schicht
DFT (Globic Antifouling)
100 µm Trockenfilm
Aushärtungszeit (Hempadur)
1–2 months full cure; 5–47 hours reworking window (temperature dependent)
Oberflächenrauhheit Anforderung
Sa 2.5 ISO 8501-1, Rugotest No. 3 or ISO roughness mean (G)
Haftungs-Mindestwert (Pull-off)
≥2,5 MPa allgemein; ≥5 MPa Immersion; ≥8 MPa >250 µm Gesamtdicke
Brennstoff-Ersparnis (Hempaguard X7)
21% über 90-Monats-Docking-Intervall (DNV validiert)
Aushärtungs-Temperaturkorrektionen
T ↓10°C → Aushärtungszeit ×2; T ↑10°C → ÷2
Product Lines
  • Hempadur (epoxy primers and intermediate coats)
  • Hempaguard (Silicon-Hydrogel Rumpfbeschichtung fuer Brennstoffeffizienz)
  • Globic (Antifouling mit Nano-Acrylat-Technologie)
🎯 Application Area
Application data not yet recorded.
Common Failures & Inspection Points
  • Area: Insufficient surface roughness or preparation before coating
    Check: Sa 2.5 (ISO 8501-1) surface roughness with Rugotest No. 3 or ISO comparator rough-medium inspect; visual inspection white surface
  • Area: Salt contamination reduces adhesion and causes blistering
    Check: Ion tester before/after blast cleaning (ISO 8502-1/2/3); limit value <50 mg/m² PSPC
  • Area: Dry film thickness <80% specification or >120% causes failure
    Check: DFT meter use; 90% measured values ≥256 µm at 320 µm nominal; edges with stripe coating; all values document
  • Area: Unvollständige Aushärtung → schlechte Schicht-Bindung, Wassereintritt, Blasenbildung
    Check: Cure time per manufacturer instructions (Hempadur 15570: 5-47 hours); temperature monitoring (T ↓10°C ×2); full cure 1-2 months before test
  • Area: Intercoat adhesion failure (<2.5 MPa) causes peeling and corrosion
    Check: ISO 4624 pull-off test after 1-2 months full cure; minimum adhesion ≥5 MPa immersion; ≥8 MPa >250 µm; 3 measurements/100 m²
  • Area: Oberflächenmängel (Blasen, Risse, Kratzer, ungleichmäßige Deckkraft) ermöglichen Wassereintritt
    Check: Visual 100% inspection for blisters/scratches/peeling; surface roughness global max. 125 µm inspect; finish standard per ship class

Type-universal inspection/maintenance points for paint & coating systems (Hempel, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Hempadur PSPC 2nd Full Coat
Product Line
Hempadur PSPC
Coating Type
tank
Imo pspc compliant
ja
Coat layer
2nd Full Coat
Application Method
airless spray
Dft (µm)
160
Voc (g/l)
190
Overcoating Interval (h)
8
Technical Specifications
DFT Standard (Hempadur PSPC)
320 µm total / 2×160 µm pro Schicht
DFT (Globic Antifouling)
100 µm Trockenfilm
Aushärtungszeit (Hempadur)
1–2 months full cure; 5–47 hours reworking window (temperature dependent)
Oberflächenrauhheit Anforderung
Sa 2.5 ISO 8501-1, Rugotest No. 3 or ISO roughness mean (G)
Haftungs-Mindestwert (Pull-off)
≥2,5 MPa allgemein; ≥5 MPa Immersion; ≥8 MPa >250 µm Gesamtdicke
Brennstoff-Ersparnis (Hempaguard X7)
21% über 90-Monats-Docking-Intervall (DNV validiert)
Aushärtungs-Temperaturkorrektionen
T ↓10°C → Aushärtungszeit ×2; T ↑10°C → ÷2
Product Lines
  • Hempadur (epoxy primers and intermediate coats)
  • Hempaguard (Silicon-Hydrogel Rumpfbeschichtung fuer Brennstoffeffizienz)
  • Globic (Antifouling mit Nano-Acrylat-Technologie)
🎯 Application Area
Application data not yet recorded.
Common Failures & Inspection Points
  • Area: Insufficient surface roughness or preparation before coating
    Check: Sa 2.5 (ISO 8501-1) surface roughness with Rugotest No. 3 or ISO comparator rough-medium inspect; visual inspection white surface
  • Area: Salt contamination reduces adhesion and causes blistering
    Check: Ion tester before/after blast cleaning (ISO 8502-1/2/3); limit value <50 mg/m² PSPC
  • Area: Dry film thickness <80% specification or >120% causes failure
    Check: DFT meter use; 90% measured values ≥256 µm at 320 µm nominal; edges with stripe coating; all values document
  • Area: Unvollständige Aushärtung → schlechte Schicht-Bindung, Wassereintritt, Blasenbildung
    Check: Cure time per manufacturer instructions (Hempadur 15570: 5-47 hours); temperature monitoring (T ↓10°C ×2); full cure 1-2 months before test
  • Area: Intercoat adhesion failure (<2.5 MPa) causes peeling and corrosion
    Check: ISO 4624 pull-off test after 1-2 months full cure; minimum adhesion ≥5 MPa immersion; ≥8 MPa >250 µm; 3 measurements/100 m²
  • Area: Oberflächenmängel (Blasen, Risse, Kratzer, ungleichmäßige Deckkraft) ermöglichen Wassereintritt
    Check: Visual 100% inspection for blisters/scratches/peeling; surface roughness global max. 125 µm inspect; finish standard per ship class

Type-universal inspection/maintenance points for paint & coating systems (Hempel, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Hempadur PSPC 320 IMO PSPC System
Product Line
Hempadur PSPC 320
Coating Type
tank
Imo pspc compliant
ja
Application Method
airless spray
Dft (µm)
320
Voc (g/l)
180
Technical Specifications
DFT Standard (Hempadur PSPC)
320 µm total / 2×160 µm pro Schicht
DFT (Globic Antifouling)
100 µm Trockenfilm
Aushärtungszeit (Hempadur)
1–2 months full cure; 5–47 hours reworking window (temperature dependent)
Oberflächenrauhheit Anforderung
Sa 2.5 ISO 8501-1, Rugotest No. 3 or ISO roughness mean (G)
Haftungs-Mindestwert (Pull-off)
≥2,5 MPa allgemein; ≥5 MPa Immersion; ≥8 MPa >250 µm Gesamtdicke
Brennstoff-Ersparnis (Hempaguard X7)
21% über 90-Monats-Docking-Intervall (DNV validiert)
Aushärtungs-Temperaturkorrektionen
T ↓10°C → Aushärtungszeit ×2; T ↑10°C → ÷2
Product Lines
  • Hempadur (epoxy primers and intermediate coats)
  • Hempaguard (Silicon-Hydrogel Rumpfbeschichtung fuer Brennstoffeffizienz)
  • Globic (Antifouling mit Nano-Acrylat-Technologie)
🎯 Application Area
Application data not yet recorded.
Common Failures & Inspection Points
  • Area: Insufficient surface roughness or preparation before coating
    Check: Sa 2.5 (ISO 8501-1) surface roughness with Rugotest No. 3 or ISO comparator rough-medium inspect; visual inspection white surface
  • Area: Salt contamination reduces adhesion and causes blistering
    Check: Ion tester before/after blast cleaning (ISO 8502-1/2/3); limit value <50 mg/m² PSPC
  • Area: Dry film thickness <80% specification or >120% causes failure
    Check: DFT meter use; 90% measured values ≥256 µm at 320 µm nominal; edges with stripe coating; all values document
  • Area: Unvollständige Aushärtung → schlechte Schicht-Bindung, Wassereintritt, Blasenbildung
    Check: Cure time per manufacturer instructions (Hempadur 15570: 5-47 hours); temperature monitoring (T ↓10°C ×2); full cure 1-2 months before test
  • Area: Intercoat adhesion failure (<2.5 MPa) causes peeling and corrosion
    Check: ISO 4624 pull-off test after 1-2 months full cure; minimum adhesion ≥5 MPa immersion; ≥8 MPa >250 µm; 3 measurements/100 m²
  • Area: Oberflächenmängel (Blasen, Risse, Kratzer, ungleichmäßige Deckkraft) ermöglichen Wassereintritt
    Check: Visual 100% inspection for blisters/scratches/peeling; surface roughness global max. 125 µm inspect; finish standard per ship class

Type-universal inspection/maintenance points for paint & coating systems (Hempel, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Hempadur Quattro XO 17720
Model Number
TAK00000D9
🎯 Application Area
Application data not yet recorded.

KCC Corporation, Ulsan Plant

16
Korepox EH2030(HS) + Korepox EH2030
Model Number
TAK00002ND
🎯 Application Area
Application data not yet recorded.
Korepox EH2351(HS)(New Version) (1 x 320 µm) (one-coat system)
Model Number
TAK00002NC
🎯 Application Area
Application data not yet recorded.
Korepox EH2351(HS)(New Version) + Korepox EH2351
Model Number
TAK00002NA
🎯 Application Area
Application data not yet recorded.
Korepox EH2351(HS)(New Version)
Model Number
TAK00002HG
🎯 Application Area
Application data not yet recorded.
Korepox EH2350(HS)(New Version)
Model Number
TAK00002FE
🎯 Application Area
Application data not yet recorded.
Korepox EH2352(HS)
Model Number
TAK00002FG
🎯 Application Area
Application data not yet recorded.
Korepox EH2030(HS)
Model Number
TAK00002FF
🎯 Application Area
Application data not yet recorded.
Korepox Tanker Shelter EP174T
Model Number
TAK000002T
🎯 Application Area
Application data not yet recorded.
KOREPOX EH2030 (New version)
Model Number
TAK000002N
🎯 Application Area
Application data not yet recorded.
Korepox H.B. EH3000 (one coat system)
Model Number
TAK00001EU
🎯 Application Area
Application data not yet recorded.
KOREPOX EH2350 (HS)
Model Number
TAK00002AR
🎯 Application Area
Application data not yet recorded.
KOREPOX H.B. EH3000
Model Number
TAK0000101
🎯 Application Area
Application data not yet recorded.
KOREPOX EH2350(HS)
Model Number
TAK0000266
🎯 Application Area
Application data not yet recorded.
KOREPOX EH3000(TH)
Model Number
TAK000021B
🎯 Application Area
Application data not yet recorded.
KOREPOX EH2350 (New Version)
Model Number
TAK000008Y
🎯 Application Area
Application data not yet recorded.
KOREPOX H.B. EH3000(W) (one coat system)
Model Number
TAK0000221
🎯 Application Area
Application data not yet recorded.

AkzoNobel / International Paint

15
Intershield 300
Model Number
TAK00000BU
🎯 Application Area
Application data not yet recorded.
Intergard 7500HS
Model Number
TAK00002M2
🎯 Application Area
Application data not yet recorded.
Intergard 7500HS + Intergard 7500
Model Number
TAK00002HT
🎯 Application Area
Application data not yet recorded.
Intergard 269 + Interline 925
Model Number
TAK000000E
🎯 Application Area
Application data not yet recorded.
Intergard 5600
Model Number
TAK000006M
🎯 Application Area
Application data not yet recorded.
Intergard 7500
Model Number
TAK00002A6
🎯 Application Area
Application data not yet recorded.
Intergard 5000
Model Number
TAK000010D
🎯 Application Area
Application data not yet recorded.
Intergard 343HS
Model Number
TAK00000VN
🎯 Application Area
Application data not yet recorded.
Intergard 403
Model Number
TAK000023F
🎯 Application Area
Application data not yet recorded.
Intergard 787
Model Number
TAK00000K1
🎯 Application Area
Application data not yet recorded.
Intergard 9700 & Intergard 9700LT
Model Number
TAK000023H
🎯 Application Area
Application data not yet recorded.
Intergard 9700 (1 x 320 µm) (one-coat system), Intergard 9700LT (1 x 320 µm) (one-coat system)
Model Number
TAK000023G
🎯 Application Area
Application data not yet recorded.
Intergard 269 + Intershield 300
Model Number
TAK00000EU
🎯 Application Area
Application data not yet recorded.
Intershield 300
Model Number
TAK00000BW
🎯 Application Area
Application data not yet recorded.
Intershield 300
Model Number
TAK00000BZ
🎯 Application Area
Application data not yet recorded.

Chugoku Marine Paints

14
Seaflo II unverified
Type
Ballast Tank Epoxy
🎯 Application Area
Application: Used on hulls, decks, ballast/cargo tanks, machinery spaces and exposed structures according to coating type and service environment. This entry applies specifically to the Ballast Tank Coating variant identified as Chugoku Marine Paints Seaflo II.
Common Failures & Inspection Points
  • Adhesion loss from inadequate surface preparation or contamination, typically indicated by flaking, peeling or blistering
  • Osmotic blistering or moisture entrapment, typically indicated by blisters and localized coating breakdown
  • Mechanical damage or abrasion, typically indicated by exposed substrate, scratches or coating loss
  • Incorrect mixing/application conditions, typically indicated by poor curing, soft film or uneven finish
  • Chemical or UV degradation beyond the coating's service suitability, typically indicated by chalking, discoloration or premature breakdown
Service: Inspect coating continuity, rusting, blistering, cracking and mechanical damage; prepare surfaces and apply repair coats strictly to the approved coating specification and manufacturer data, including exact film thickness and curing requirements.
Spare Parts: Maintain compatible primer, intermediate/topcoat materials, thinners and repair consumables within shelf-life and storage requirements; use only products approved for the existing coating scheme.
Seaflo NEO unverified
Type
Hi-Build Ballast Epoxy
Pspc compliant
ja
🎯 Application Area
Application: Used on hulls, decks, ballast/cargo tanks, machinery spaces and exposed structures according to coating type and service environment. This entry applies specifically to the Ballast Tank Coating variant identified as Chugoku Marine Paints Seaflo NEO.
Common Failures & Inspection Points
  • Adhesion loss from inadequate surface preparation or contamination, typically indicated by flaking, peeling or blistering
  • Osmotic blistering or moisture entrapment, typically indicated by blisters and localized coating breakdown
  • Mechanical damage or abrasion, typically indicated by exposed substrate, scratches or coating loss
  • Incorrect mixing/application conditions, typically indicated by poor curing, soft film or uneven finish
  • Chemical or UV degradation beyond the coating's service suitability, typically indicated by chalking, discoloration or premature breakdown
Service: Inspect coating continuity, rusting, blistering, cracking and mechanical damage; prepare surfaces and apply repair coats strictly to the approved coating specification and manufacturer data, including exact film thickness and curing requirements.
Spare Parts: Maintain compatible primer, intermediate/topcoat materials, thinners and repair consumables within shelf-life and storage requirements; use only products approved for the existing coating scheme.
CMP BT Double Bottom unverified
Position
Double Bottom
Pspc compliant
ja
🎯 Application Area
Application: It is used for marine corrosion and surface protection on merchant ships, passenger vessels, offshore units or other vessel types where this equipment category is fitted.
Common Failures & Inspection Points
  • Blistering caused by moisture, osmotic contamination or poor surface preparation, resulting in raised bubbles and localized coating loss
  • Delamination caused by inadequate surface preparation, contamination or incompatible overcoating, resulting in peeling or loss of adhesion
  • Underfilm corrosion caused by coating damage, holidays or poor edge coverage, resulting in rust staining and progressive coating breakdown
  • Cracking or embrittlement caused by excessive film build, aging or substrate movement, resulting in visible cracks and loss of barrier protection
  • Abrasion, impact or chemical attack caused by service exposure, resulting in worn areas, discoloration or exposed substrate
Service: Inspect coated surfaces for blistering, rusting, cracking, peeling, mechanical damage and edge breakdown. Identify and remove the cause of moisture, contamination or chemical attack before local repair. Prepare the substrate and apply compatible repair coats according to the approved coating specification. Maintain batch, mixing, curing and environmental records where required by the vessel coating plan. Pay particular attention to welds, edges, drains and high-abrasion zones. Refer to the manufacturer documentation for the exact figure for surface preparation, dry-film thickness, curing and overcoating requirements.
Spare Parts: Keep compatible primer, intermediate and topcoat materials required by the vessel coating scheme together with approved thinners, repair materials and application consumables. Respect shelf life and storage conditions and do not substitute a different coating chemistry without compatibility checks.
CMP BT Side Tank unverified
Position
Side Tank
Pspc compliant
ja
🎯 Application Area
Application: Corrosion, fouling, chemical, slip or fire protection of hull, tanks, decks and machinery spaces according to the listed coating system.
Common Failures & Inspection Points
  • Blistering caused by moisture, osmotic contamination or poor surface preparation, resulting in raised bubbles and localized coating loss
  • Delamination caused by inadequate surface preparation, contamination or incompatible overcoating, resulting in peeling or loss of adhesion
  • Underfilm corrosion caused by coating damage, holidays or poor edge coverage, resulting in rust staining and progressive coating breakdown
  • Cracking or embrittlement caused by excessive film build, aging or substrate movement, resulting in visible cracks and loss of barrier protection
  • Abrasion, impact or chemical attack caused by service exposure, resulting in worn areas, discoloration or exposed substrate
Service: Inspect coated surfaces for blistering, rusting, cracking, peeling, mechanical damage and edge breakdown. Identify and remove the cause of moisture, contamination or chemical attack before local repair. Prepare the substrate and apply compatible repair coats according to the approved coating specification. Maintain batch, mixing, curing and environmental records where required by the vessel coating plan. Pay particular attention to welds, edges, drains and high-abrasion zones. Refer to the manufacturer documentation for the exact figure for surface preparation, dry-film thickness, curing and overcoating requirements.
Spare Parts: Keep compatible primer, intermediate and topcoat materials required by the vessel coating scheme together with approved thinners, repair materials and application consumables. Coating shelf life and storage conditions must be respected. Do not substitute a different coating chemistry without compatibility and approval checks.
CMP BT Fore Peak unverified
Position
Fore Peak
Pspc compliant
ja
🎯 Application Area
Application: Corrosion, fouling, chemical, slip or fire protection of hull, tanks, decks and machinery spaces according to the listed coating system.
Common Failures & Inspection Points
  • Blistering caused by moisture, osmotic contamination or poor surface preparation, resulting in raised bubbles and localized coating loss
  • Delamination caused by inadequate surface preparation, contamination or incompatible overcoating, resulting in peeling or loss of adhesion
  • Underfilm corrosion caused by coating damage, holidays or poor edge coverage, resulting in rust staining and progressive coating breakdown
  • Cracking or embrittlement caused by excessive film build, aging or substrate movement, resulting in visible cracks and loss of barrier protection
  • Abrasion, impact or chemical attack caused by service exposure, resulting in worn areas, discoloration or exposed substrate
Service: Inspect coated surfaces for blistering, rusting, cracking, peeling, mechanical damage and edge breakdown. Identify and remove the cause of moisture, contamination or chemical attack before local repair. Prepare the substrate and apply compatible repair coats according to the approved coating specification. Maintain batch, mixing, curing and environmental records where required by the vessel coating plan. Pay particular attention to welds, edges, drains and high-abrasion zones. Refer to the manufacturer documentation for the exact figure for surface preparation, dry-film thickness, curing and overcoating requirements.
Spare Parts: Keep compatible primer, intermediate and topcoat materials required by the vessel coating scheme together with approved thinners, repair materials and application consumables. Coating shelf life and storage conditions must be respected. Do not substitute a different coating chemistry without compatibility and approval checks.
CMP BT Aft Peak unverified
Position
Aft Peak
Pspc compliant
ja
🎯 Application Area
Application: Corrosion, fouling, chemical, slip or fire protection of hull, tanks, decks and machinery spaces according to the listed coating system.
Common Failures & Inspection Points
  • Blistering caused by moisture, osmotic contamination or poor surface preparation, resulting in raised bubbles and localized coating loss
  • Delamination caused by inadequate surface preparation, contamination or incompatible overcoating, resulting in peeling or loss of adhesion
  • Underfilm corrosion caused by coating damage, holidays or poor edge coverage, resulting in rust staining and progressive coating breakdown
  • Cracking or embrittlement caused by excessive film build, aging or substrate movement, resulting in visible cracks and loss of barrier protection
  • Abrasion, impact or chemical attack caused by service exposure, resulting in worn areas, discoloration or exposed substrate
Service: Inspect coated surfaces for blistering, rusting, cracking, peeling, mechanical damage and edge breakdown. Identify and remove the cause of moisture, contamination or chemical attack before local repair. Prepare the substrate and apply compatible repair coats according to the approved coating specification. Maintain batch, mixing, curing and environmental records where required by the vessel coating plan. Pay particular attention to welds, edges, drains and high-abrasion zones. Refer to the manufacturer documentation for the exact figure for surface preparation, dry-film thickness, curing and overcoating requirements.
Spare Parts: Keep compatible primer, intermediate and topcoat materials required by the vessel coating scheme together with approved thinners, repair materials and application consumables. Coating shelf life and storage conditions must be respected. Do not substitute a different coating chemistry without compatibility and approval checks.
CMP BT Upper Wing unverified
Position
Upper Wing
Pspc compliant
ja
🎯 Application Area
Application: Corrosion, fouling, chemical, slip or fire protection of hull, tanks, decks and machinery spaces according to the listed coating system.
Common Failures & Inspection Points
  • Blistering caused by moisture, osmotic contamination or poor surface preparation, resulting in raised bubbles and localized coating loss
  • Delamination caused by inadequate surface preparation, contamination or incompatible overcoating, resulting in peeling or loss of adhesion
  • Underfilm corrosion caused by coating damage, holidays or poor edge coverage, resulting in rust staining and progressive coating breakdown
  • Cracking or embrittlement caused by excessive film build, aging or substrate movement, resulting in visible cracks and loss of barrier protection
  • Abrasion, impact or chemical attack caused by service exposure, resulting in worn areas, discoloration or exposed substrate
Service: Inspect coated surfaces for blistering, rusting, cracking, peeling, mechanical damage and edge breakdown. Identify and remove the cause of moisture, contamination or chemical attack before local repair. Prepare the substrate and apply compatible repair coats according to the approved coating specification. Maintain batch, mixing, curing and environmental records where required by the vessel coating plan. Pay particular attention to welds, edges, drains and high-abrasion zones. Refer to the manufacturer documentation for the exact figure for surface preparation, dry-film thickness, curing and overcoating requirements.
Spare Parts: Keep compatible primer, intermediate and topcoat materials required by the vessel coating scheme together with approved thinners, repair materials and application consumables. Coating shelf life and storage conditions must be respected. Do not substitute a different coating chemistry without compatibility and approval checks.
Chugoku Marine Paints Coal Tar Epoxy unverified
Type
Coal Tar Epoxy
🎯 Application Area
Application: Used throughout ships and offshore units for corrosion protection, fouling control, deck safety and protection of tanks or exposed structures.
Common Failures & Inspection Points
  • Poor surface preparation can cause early loss of adhesion, seen as peeling, blistering or underfilm corrosion
  • Contamination or moisture during application can create coating defects, noticed as pinholes, craters, soft film or poor cure
  • Mechanical damage can expose the substrate, seen as scratches, impact damage or localized rusting
  • Incompatible overcoating or incorrect application sequence can cause wrinkling or delamination, found during inspection
  • Ageing and environmental attack can reduce film integrity, seen as chalking, erosion, cracking or fouling depending on service
Service: Inspect coating continuity, adhesion-related defects, corrosion breakthrough and damage at welds, edges and high-wear areas. Repairs should use the approved coating scheme and surface-preparation procedure. Film thickness, curing times and environmental application limits not supplied in the source entry must be taken from the coating manufacturer’s documentation.
Spare Parts: Maintain compatible repair coating, approved thinner or cleaner where permitted, and the vessel’s standard surface-preparation and application consumables.
CMP Sea Jet 055 BT unverified
Product Line
Sea Jet
Coating Type
tank
Application Method
airless spray
Dft (µm)
300
Voc (g/l)
160
Overcoating Interval (h)
12
🎯 Application Area
Application: Corrosion, fouling, chemical, slip or fire protection of hull, tanks, decks and machinery spaces according to the listed coating system.
Common Failures & Inspection Points
  • Blistering caused by moisture, osmotic contamination or poor surface preparation, resulting in raised bubbles and localized coating loss
  • Delamination caused by inadequate surface preparation, contamination or incompatible overcoating, resulting in peeling or loss of adhesion
  • Underfilm corrosion caused by coating damage, holidays or poor edge coverage, resulting in rust staining and progressive coating breakdown
  • Cracking or embrittlement caused by excessive film build, aging or substrate movement, resulting in visible cracks and loss of barrier protection
  • Abrasion, impact or chemical attack caused by service exposure, resulting in worn areas, discoloration or exposed substrate
Service: Inspect coated surfaces for blistering, rusting, cracking, peeling, mechanical damage and edge breakdown. Identify and remove the cause of moisture, contamination or chemical attack before local repair. Prepare the substrate and apply compatible repair coats according to the approved coating specification. Maintain batch, mixing, curing and environmental records where required by the vessel coating plan. Pay particular attention to welds, edges, drains and high-abrasion zones. Refer to the manufacturer documentation for the exact figure for surface preparation, dry-film thickness, curing and overcoating requirements.
Spare Parts: Keep compatible primer, intermediate and topcoat materials required by the vessel coating scheme together with approved thinners, repair materials and application consumables. Coating shelf life and storage conditions must be respected. Do not substitute a different coating chemistry without compatibility and approval checks.
CMP Marine BT 700 unverified
Product Line
Marine BT
Coating Type
tank
Application Method
airless spray
Dft (µm)
320
Voc (g/l)
150
Overcoating Interval (h)
12
🎯 Application Area
Application: Corrosion, fouling, chemical, slip or fire protection of hull, tanks, decks and machinery spaces according to the listed coating system.
Common Failures & Inspection Points
  • Blistering caused by moisture, osmotic contamination or poor surface preparation, resulting in raised bubbles and localized coating loss
  • Delamination caused by inadequate surface preparation, contamination or incompatible overcoating, resulting in peeling or loss of adhesion
  • Underfilm corrosion caused by coating damage, holidays or poor edge coverage, resulting in rust staining and progressive coating breakdown
  • Cracking or embrittlement caused by excessive film build, aging or substrate movement, resulting in visible cracks and loss of barrier protection
  • Abrasion, impact or chemical attack caused by service exposure, resulting in worn areas, discoloration or exposed substrate
Service: Inspect coated surfaces for blistering, rusting, cracking, peeling, mechanical damage and edge breakdown. Identify and remove the cause of moisture, contamination or chemical attack before local repair. Prepare the substrate and apply compatible repair coats according to the approved coating specification. Maintain batch, mixing, curing and environmental records where required by the vessel coating plan. Pay particular attention to welds, edges, drains and high-abrasion zones. Refer to the manufacturer documentation for the exact figure for surface preparation, dry-film thickness, curing and overcoating requirements.
Spare Parts: Keep compatible primer, intermediate and topcoat materials required by the vessel coating scheme together with approved thinners, repair materials and application consumables. Coating shelf life and storage conditions must be respected. Do not substitute a different coating chemistry without compatibility and approval checks.
CMP PSPC System Stripe Coat unverified
Product Line
CMP PSPC System
Coating Type
tank
Imo pspc compliant
ja
Coat layer
Stripe Coat
Application Method
airless spray
Dft (µm)
160
Voc (g/l)
190
Overcoating Interval (h)
8
🎯 Application Area
Application: Used throughout ships and offshore units for corrosion protection, fouling control, deck safety and protection of tanks or exposed structures.
Common Failures & Inspection Points
  • Poor surface preparation can cause early loss of adhesion, seen as peeling, blistering or underfilm corrosion
  • Contamination or moisture during application can create coating defects, noticed as pinholes, craters, soft film or poor cure
  • Mechanical damage can expose the substrate, seen as scratches, impact damage or localized rusting
  • Incompatible overcoating or incorrect application sequence can cause wrinkling or delamination, found during inspection
  • Ageing and environmental attack can reduce film integrity, seen as chalking, erosion, cracking or fouling depending on service
Service: Inspect coating continuity, adhesion-related defects, corrosion breakthrough and damage at welds, edges and high-wear areas. Repairs should use the approved coating scheme and surface-preparation procedure. Film thickness, curing times and environmental application limits not supplied in the source entry must be taken from the coating manufacturer’s documentation.
Spare Parts: Maintain compatible repair coating, approved thinner or cleaner where permitted, and the vessel’s standard surface-preparation and application consumables.
CMP PSPC System 1st Full Coat unverified
Product Line
CMP PSPC System
Coating Type
tank
Imo pspc compliant
ja
Coat layer
1st Full Coat
Application Method
airless spray
Dft (µm)
160
Voc (g/l)
190
Overcoating Interval (h)
8
🎯 Application Area
Application: Used throughout ships and offshore units for corrosion protection, fouling control, deck safety and protection of tanks or exposed structures.
Common Failures & Inspection Points
  • Poor surface preparation can cause early loss of adhesion, seen as peeling, blistering or underfilm corrosion
  • Contamination or moisture during application can create coating defects, noticed as pinholes, craters, soft film or poor cure
  • Mechanical damage can expose the substrate, seen as scratches, impact damage or localized rusting
  • Incompatible overcoating or incorrect application sequence can cause wrinkling or delamination, found during inspection
  • Ageing and environmental attack can reduce film integrity, seen as chalking, erosion, cracking or fouling depending on service
Service: Inspect coating continuity, adhesion-related defects, corrosion breakthrough and damage at welds, edges and high-wear areas. Repairs should use the approved coating scheme and surface-preparation procedure. Film thickness, curing times and environmental application limits not supplied in the source entry must be taken from the coating manufacturer’s documentation.
Spare Parts: Maintain compatible repair coating, approved thinner or cleaner where permitted, and the vessel’s standard surface-preparation and application consumables.
CMP PSPC System 2nd Full Coat unverified
Product Line
CMP PSPC System
Coating Type
tank
Imo pspc compliant
ja
Coat layer
2nd Full Coat
Application Method
airless spray
Dft (µm)
160
Voc (g/l)
190
Overcoating Interval (h)
8
🎯 Application Area
Application: Used throughout ships and offshore units for corrosion protection, fouling control, deck safety and protection of tanks or exposed structures.
Common Failures & Inspection Points
  • Poor surface preparation can cause early loss of adhesion, seen as peeling, blistering or underfilm corrosion
  • Contamination or moisture during application can create coating defects, noticed as pinholes, craters, soft film or poor cure
  • Mechanical damage can expose the substrate, seen as scratches, impact damage or localized rusting
  • Incompatible overcoating or incorrect application sequence can cause wrinkling or delamination, found during inspection
  • Ageing and environmental attack can reduce film integrity, seen as chalking, erosion, cracking or fouling depending on service
Service: Inspect coating continuity, adhesion-related defects, corrosion breakthrough and damage at welds, edges and high-wear areas. Repairs should use the approved coating scheme and surface-preparation procedure. Film thickness, curing times and environmental application limits not supplied in the source entry must be taken from the coating manufacturer’s documentation.
Spare Parts: Maintain compatible repair coating, approved thinner or cleaner where permitted, and the vessel’s standard surface-preparation and application consumables.
CMP PSPC BT 700 IMO PSPC System unverified
Product Line
CMP PSPC BT 700
Coating Type
tank
Imo pspc compliant
ja
Application Method
airless spray
Dft (µm)
320
Voc (g/l)
180
🎯 Application Area
Application: Used throughout ships and offshore units for corrosion protection, fouling control, deck safety and protection of tanks or exposed structures.
Common Failures & Inspection Points
  • Poor surface preparation can cause early loss of adhesion, seen as peeling, blistering or underfilm corrosion
  • Contamination or moisture during application can create coating defects, noticed as pinholes, craters, soft film or poor cure
  • Mechanical damage can expose the substrate, seen as scratches, impact damage or localized rusting
  • Incompatible overcoating or incorrect application sequence can cause wrinkling or delamination, found during inspection
  • Ageing and environmental attack can reduce film integrity, seen as chalking, erosion, cracking or fouling depending on service
Service: Inspect coating continuity, adhesion-related defects, corrosion breakthrough and damage at welds, edges and high-wear areas. Repairs should use the approved coating scheme and surface-preparation procedure. Film thickness, curing times and environmental application limits not supplied in the source entry must be taken from the coating manufacturer’s documentation.
Spare Parts: Maintain compatible repair coating, approved thinner or cleaner where permitted, and the vessel’s standard surface-preparation and application consumables.

Chugoku Marine Paints, Ltd. (Hiroshima Head Office)

14
BANNOH 3000 and BANNOH 3000 QD
Model Number
TAK000009G
🎯 Application Area
Application data not yet recorded.
EPICON ZINC RICH PRIMER B-2 + BANNOH 1500 and EPICON ZINC RICH PRIMER B-2 + BANNOH 1500 QD
Model Number
TAK00002MN
🎯 Application Area
Application data not yet recorded.
CMP NOVA 2000
Model Number
TAK00002KD
🎯 Application Area
Application data not yet recorded.
CMP NOVA 2000 W QD
Model Number
TAK00001XZ
🎯 Application Area
Application data not yet recorded.
EPICON ZINC RICH PRIMER B-2 + CMP NOVA 2000 W QD
Model Number
TAK00001Y0
🎯 Application Area
Application data not yet recorded.
CMP NOVA 2000 and CMP NOVA 2000 QD
Model Number
TAK00001SX
🎯 Application Area
Application data not yet recorded.
EPICON ZINC RICH PRIMER B-2 + CMP NOVA 2000, EPICON ZINC RICH PRIMER B-2 + CMP NOVA 2000 QD
Model Number
TAK00001SY
🎯 Application Area
Application data not yet recorded.
BANNOH 1500 and BANNOH 1500 QD
Model Number
TAK00001RS
🎯 Application Area
Application data not yet recorded.
EPICON ZINC RICH PRIMER B-2 + BANNOH 500 and EPICON ZINC RICH PRIMER B-2 + BANNOH 500 QD
Model Number
TAK00001RT
🎯 Application Area
Application data not yet recorded.
BANNOH 1500
Model Number
TAK00001EX
🎯 Application Area
Application data not yet recorded.
EPICON ZINC RICH PRIMER B-2 + CMP NOVA 2000 and EPICON ZINC RICH PRIMER B-2 + CMP NOVA 2000 QD
Model Number
TAK0000152
🎯 Application Area
Application data not yet recorded.
SD ZINC 100QD + CMP NOVA 2000 and SD ZINC 100QD + CMP NOVA 2000 QD
Model Number
TAK00000VD
🎯 Application Area
Application data not yet recorded.
BANNOH 2000 and BANNOH 2000 QD
Model Number
TAK00000T5
🎯 Application Area
Application data not yet recorded.
EPICON ZINC RICH PRIMER B-2 (M2-11000A) + CMP NOVA 2000 /QD
Model Number
TAK0000220
🎯 Application Area
Application data not yet recorded.

Sherwin-Williams Marine

14
Dura-Plate 235 BT
Type
Ballast Tank Epoxy
Technical Specifications
Volume Solids (Seaguard 5000 HS)
73 ± 2% gemischt
Mischverhaeltnis
1:1 by volume (two-component)
VOC (EPA Method 24)
<250 g/L
Nenndicke DFT
0,1778–0,2540 mm (7–10 mils)
PSPC 90/10 DFT-Regel
90% der Messungen ≥ NDFT; 10% mindestens ≥ 0,9×NDFT (typisch 320 µm für Ballasttank)
Oberflächenprofil (nach Blastdreinigung)
ISO 8501-3 P2; minimum 2 mm rounded edge after grinding
Product Lines
  • Seaguard 5000 HS (High-Solids Epoxy Primer)
  • Seaguard Marine Epoxy
  • Pro-Line Series (Pro-Glo Xpress, Pro-Line 4800, Pro-Line 3000)
  • Sher-Loxane 800 (Epoxy-Polyurethane Hybrid)
  • Seaguard 1000
  • Seaguard 6100
🎯 Application Area
Application data not yet recorded.
Common Failures & Inspection Points
  • Area: Dry Film Thickness (DFT) does not meet PSPC 90/10 requirement
    Check: Perform DFT measurement with calibrated wet film thickness gauge (ASTM D7091): 90% of all measurements ≥ nominal DFT; maximum 10% may be between 0.9×NDFT and NDFT. Minimum 3 measurements per square meter required. Measurement only after minimum 1 week drying time.
  • Area: Haftung des Beschichtungssystems zu Substrat unzureichend (Abloesung)
    Check: Perform pull-off adhesion test (ASTM D4541) with portable adhesion tester: glue dolly to dry layer (≥1 week cure), increase perpendicular tensile force at constant rate until failure. Determine reading in MPa/PSI. Classify failure mode (adhesion failure at substrate, layer-to-layer failure or substrate failure). Minimum 5 test points per application area.
  • Area: Surface profile (anchor pattern) insufficient for adhesion after blast cleaning
    Check: Measure surface profile per ASTM D4417 (Method B: depth micrometer, Method C: replica tape) BEFORE application. Determine Mean Maximum Profile (h_max) by averaging at least 20 peak-to-valley measurements. Required profile typically 50–75 µm for epoxy systems. If too shallow (<50 µm): blast clean again; if too deep (>75 µm): not acceptable.
  • Area: Fehlstellen (Pinholes/Holidays) in der Beschichtung — Korrosionsnukleation
    Check: Deploy holiday/pinhole detector: low-voltage wet brush method (≤500 µm thickness) or high-voltage spark tester (>250 µm). Move electrode surface step-by-step over all surfaces. Alarm/needle indication shows defect. Mark and document. Alternatively: UV-pigment method for large-area tank testing in darkness.
  • Area: Application conditions (temperature/humidity/dew point) violate PSPC requirements — adhesion and cure failures
    Check: During application and cure continuously document: steel temperature (surface temperature with infrared pyrometer), relative humidity (hygrometer), dew point. Ensure steel temperature is at least 3°C above dew point (condensation risk). Air temperature between 2–43°C (Seaguard 5000 HS: 35–110°F). Document in inspection record with date/time.
  • Area: Visuelle Maengel: Glanzgrad, Farbkontinuitaet, Kratzer, Blasen, Schalebildung, Kratzer
    Check: Inspect visually against reference standard per ASTM D4141 Method C (gloss/color). Scan surfaces for weak points: scratches, blisters (pores), shell formation, scratches, color spots. Measure defect area with calipers and document photographically. Some surface defects (small scratches <5 mm²) are acceptable per PSPC tolerances; blisters or shell formation = rework required.

Type universal inspection/maintenance points for Paint & Coating Systems (Sherwin-Williams Marine, Mega-Schwarm 2026-06). Per-model specs not auto-populated.

Sherwin-Williams Marine Dura-Plate 301W
Dura-Plate 301W
Type
Water Ballast Epoxy
Technical Specifications
Volume Solids (Seaguard 5000 HS)
73 ± 2% gemischt
Mischverhaeltnis
1:1 by volume (two-component)
VOC (EPA Method 24)
<250 g/L
Nenndicke DFT
0,1778–0,2540 mm (7–10 mils)
PSPC 90/10 DFT-Regel
90% der Messungen ≥ NDFT; 10% mindestens ≥ 0,9×NDFT (typisch 320 µm für Ballasttank)
Oberflächenprofil (nach Blastdreinigung)
ISO 8501-3 P2; minimum 2 mm rounded edge after grinding
Product Lines
  • Seaguard 5000 HS (High-Solids Epoxy Primer)
  • Seaguard Marine Epoxy
  • Pro-Line Series (Pro-Glo Xpress, Pro-Line 4800, Pro-Line 3000)
  • Sher-Loxane 800 (Epoxy-Polyurethane Hybrid)
  • Seaguard 1000
  • Seaguard 6100
🎯 Application Area
Application data not yet recorded.
Common Failures & Inspection Points
  • Area: Dry Film Thickness (DFT) does not meet PSPC 90/10 requirement
    Check: Perform DFT measurement with calibrated wet film thickness gauge (ASTM D7091): 90% of all measurements ≥ nominal DFT; maximum 10% may be between 0.9×NDFT and NDFT. Minimum 3 measurements per square meter required. Measurement only after minimum 1 week drying time.
  • Area: Haftung des Beschichtungssystems zu Substrat unzureichend (Abloesung)
    Check: Perform pull-off adhesion test (ASTM D4541) with portable adhesion tester: glue dolly to dry layer (≥1 week cure), increase perpendicular tensile force at constant rate until failure. Determine reading in MPa/PSI. Classify failure mode (adhesion failure at substrate, layer-to-layer failure or substrate failure). Minimum 5 test points per application area.
  • Area: Surface profile (anchor pattern) insufficient for adhesion after blast cleaning
    Check: Measure surface profile per ASTM D4417 (Method B: depth micrometer, Method C: replica tape) BEFORE application. Determine Mean Maximum Profile (h_max) by averaging at least 20 peak-to-valley measurements. Required profile typically 50–75 µm for epoxy systems. If too shallow (<50 µm): blast clean again; if too deep (>75 µm): not acceptable.
  • Area: Fehlstellen (Pinholes/Holidays) in der Beschichtung — Korrosionsnukleation
    Check: Deploy holiday/pinhole detector: low-voltage wet brush method (≤500 µm thickness) or high-voltage spark tester (>250 µm). Move electrode surface step-by-step over all surfaces. Alarm/needle indication shows defect. Mark and document. Alternatively: UV-pigment method for large-area tank testing in darkness.
  • Area: Application conditions (temperature/humidity/dew point) violate PSPC requirements — adhesion and cure failures
    Check: During application and cure continuously document: steel temperature (surface temperature with infrared pyrometer), relative humidity (hygrometer), dew point. Ensure steel temperature is at least 3°C above dew point (condensation risk). Air temperature between 2–43°C (Seaguard 5000 HS: 35–110°F). Document in inspection record with date/time.
  • Area: Visuelle Maengel: Glanzgrad, Farbkontinuitaet, Kratzer, Blasen, Schalebildung, Kratzer
    Check: Inspect visually against reference standard per ASTM D4141 Method C (gloss/color). Scan surfaces for weak points: scratches, blisters (pores), shell formation, scratches, color spots. Measure defect area with calipers and document photographically. Some surface defects (small scratches <5 mm²) are acceptable per PSPC tolerances; blisters or shell formation = rework required.

Type universal inspection/maintenance points for Paint & Coating Systems (Sherwin-Williams Marine, Mega-Schwarm 2026-06). Per-model specs not auto-populated.

SW BT Double Bottom
Position
Double Bottom
Pspc compliant
ja
Technical Specifications
Volume Solids (Seaguard 5000 HS)
73 ± 2% gemischt
Mischverhaeltnis
1:1 by volume (two-component)
VOC (EPA Method 24)
<250 g/L
Nenndicke DFT
0,1778–0,2540 mm (7–10 mils)
PSPC 90/10 DFT-Regel
90% der Messungen ≥ NDFT; 10% mindestens ≥ 0,9×NDFT (typisch 320 µm für Ballasttank)
Oberflächenprofil (nach Blastdreinigung)
ISO 8501-3 P2; minimum 2 mm rounded edge after grinding
Product Lines
  • Seaguard 5000 HS (High-Solids Epoxy Primer)
  • Seaguard Marine Epoxy
  • Pro-Line Series (Pro-Glo Xpress, Pro-Line 4800, Pro-Line 3000)
  • Sher-Loxane 800 (Epoxy-Polyurethane Hybrid)
  • Seaguard 1000
  • Seaguard 6100
🎯 Application Area
Application data not yet recorded.
Common Failures & Inspection Points
  • Area: Dry Film Thickness (DFT) does not meet PSPC 90/10 requirement
    Check: Perform DFT measurement with calibrated wet film thickness gauge (ASTM D7091): 90% of all measurements ≥ nominal DFT; maximum 10% may be between 0.9×NDFT and NDFT. Minimum 3 measurements per square meter required. Measurement only after minimum 1 week drying time.
  • Area: Haftung des Beschichtungssystems zu Substrat unzureichend (Abloesung)
    Check: Perform pull-off adhesion test (ASTM D4541) with portable adhesion tester: glue dolly to dry layer (≥1 week cure), increase perpendicular tensile force at constant rate until failure. Determine reading in MPa/PSI. Classify failure mode (adhesion failure at substrate, layer-to-layer failure or substrate failure). Minimum 5 test points per application area.
  • Area: Surface profile (anchor pattern) insufficient for adhesion after blast cleaning
    Check: Measure surface profile per ASTM D4417 (Method B: depth micrometer, Method C: replica tape) BEFORE application. Determine Mean Maximum Profile (h_max) by averaging at least 20 peak-to-valley measurements. Required profile typically 50–75 µm for epoxy systems. If too shallow (<50 µm): blast clean again; if too deep (>75 µm): not acceptable.
  • Area: Fehlstellen (Pinholes/Holidays) in der Beschichtung — Korrosionsnukleation
    Check: Deploy holiday/pinhole detector: low-voltage wet brush method (≤500 µm thickness) or high-voltage spark tester (>250 µm). Move electrode surface step-by-step over all surfaces. Alarm/needle indication shows defect. Mark and document. Alternatively: UV-pigment method for large-area tank testing in darkness.
  • Area: Application conditions (temperature/humidity/dew point) violate PSPC requirements — adhesion and cure failures
    Check: During application and cure continuously document: steel temperature (surface temperature with infrared pyrometer), relative humidity (hygrometer), dew point. Ensure steel temperature is at least 3°C above dew point (condensation risk). Air temperature between 2–43°C (Seaguard 5000 HS: 35–110°F). Document in inspection record with date/time.
  • Area: Visuelle Maengel: Glanzgrad, Farbkontinuitaet, Kratzer, Blasen, Schalebildung, Kratzer
    Check: Inspect visually against reference standard per ASTM D4141 Method C (gloss/color). Scan surfaces for weak points: scratches, blisters (pores), shell formation, scratches, color spots. Measure defect area with calipers and document photographically. Some surface defects (small scratches <5 mm²) are acceptable per PSPC tolerances; blisters or shell formation = rework required.

Type universal inspection/maintenance points for Paint & Coating Systems (Sherwin-Williams Marine, Mega-Schwarm 2026-06). Per-model specs not auto-populated.

SW BT Side Tank
Position
Side Tank
Pspc compliant
ja
Technical Specifications
Volume Solids (Seaguard 5000 HS)
73 ± 2% gemischt
Mischverhaeltnis
1:1 by volume (two-component)
VOC (EPA Method 24)
<250 g/L
Nenndicke DFT
0,1778–0,2540 mm (7–10 mils)
PSPC 90/10 DFT-Regel
90% der Messungen ≥ NDFT; 10% mindestens ≥ 0,9×NDFT (typisch 320 µm für Ballasttank)
Oberflächenprofil (nach Blastdreinigung)
ISO 8501-3 P2; minimum 2 mm rounded edge after grinding
Product Lines
  • Seaguard 5000 HS (High-Solids Epoxy Primer)
  • Seaguard Marine Epoxy
  • Pro-Line Series (Pro-Glo Xpress, Pro-Line 4800, Pro-Line 3000)
  • Sher-Loxane 800 (Epoxy-Polyurethane Hybrid)
  • Seaguard 1000
  • Seaguard 6100
🎯 Application Area
Application data not yet recorded.
Common Failures & Inspection Points
  • Area: Dry Film Thickness (DFT) does not meet PSPC 90/10 requirement
    Check: Perform DFT measurement with calibrated wet film thickness gauge (ASTM D7091): 90% of all measurements ≥ nominal DFT; maximum 10% may be between 0.9×NDFT and NDFT. Minimum 3 measurements per square meter required. Measurement only after minimum 1 week drying time.
  • Area: Haftung des Beschichtungssystems zu Substrat unzureichend (Abloesung)
    Check: Perform pull-off adhesion test (ASTM D4541) with portable adhesion tester: glue dolly to dry layer (≥1 week cure), increase perpendicular tensile force at constant rate until failure. Determine reading in MPa/PSI. Classify failure mode (adhesion failure at substrate, layer-to-layer failure or substrate failure). Minimum 5 test points per application area.
  • Area: Surface profile (anchor pattern) insufficient for adhesion after blast cleaning
    Check: Measure surface profile per ASTM D4417 (Method B: depth micrometer, Method C: replica tape) BEFORE application. Determine Mean Maximum Profile (h_max) by averaging at least 20 peak-to-valley measurements. Required profile typically 50–75 µm for epoxy systems. If too shallow (<50 µm): blast clean again; if too deep (>75 µm): not acceptable.
  • Area: Fehlstellen (Pinholes/Holidays) in der Beschichtung — Korrosionsnukleation
    Check: Deploy holiday/pinhole detector: low-voltage wet brush method (≤500 µm thickness) or high-voltage spark tester (>250 µm). Move electrode surface step-by-step over all surfaces. Alarm/needle indication shows defect. Mark and document. Alternatively: UV-pigment method for large-area tank testing in darkness.
  • Area: Application conditions (temperature/humidity/dew point) violate PSPC requirements — adhesion and cure failures
    Check: During application and cure continuously document: steel temperature (surface temperature with infrared pyrometer), relative humidity (hygrometer), dew point. Ensure steel temperature is at least 3°C above dew point (condensation risk). Air temperature between 2–43°C (Seaguard 5000 HS: 35–110°F). Document in inspection record with date/time.
  • Area: Visuelle Maengel: Glanzgrad, Farbkontinuitaet, Kratzer, Blasen, Schalebildung, Kratzer
    Check: Inspect visually against reference standard per ASTM D4141 Method C (gloss/color). Scan surfaces for weak points: scratches, blisters (pores), shell formation, scratches, color spots. Measure defect area with calipers and document photographically. Some surface defects (small scratches <5 mm²) are acceptable per PSPC tolerances; blisters or shell formation = rework required.

Type universal inspection/maintenance points for Paint & Coating Systems (Sherwin-Williams Marine, Mega-Schwarm 2026-06). Per-model specs not auto-populated.

SW BT Fore Peak
Position
Fore Peak
Pspc compliant
ja
Technical Specifications
Volume Solids (Seaguard 5000 HS)
73 ± 2% gemischt
Mischverhaeltnis
1:1 by volume (two-component)
VOC (EPA Method 24)
<250 g/L
Nenndicke DFT
0,1778–0,2540 mm (7–10 mils)
PSPC 90/10 DFT-Regel
90% der Messungen ≥ NDFT; 10% mindestens ≥ 0,9×NDFT (typisch 320 µm für Ballasttank)
Oberflächenprofil (nach Blastdreinigung)
ISO 8501-3 P2; minimum 2 mm rounded edge after grinding
Product Lines
  • Seaguard 5000 HS (High-Solids Epoxy Primer)
  • Seaguard Marine Epoxy
  • Pro-Line Series (Pro-Glo Xpress, Pro-Line 4800, Pro-Line 3000)
  • Sher-Loxane 800 (Epoxy-Polyurethane Hybrid)
  • Seaguard 1000
  • Seaguard 6100
🎯 Application Area
Application data not yet recorded.
Common Failures & Inspection Points
  • Area: Dry Film Thickness (DFT) does not meet PSPC 90/10 requirement
    Check: Perform DFT measurement with calibrated wet film thickness gauge (ASTM D7091): 90% of all measurements ≥ nominal DFT; maximum 10% may be between 0.9×NDFT and NDFT. Minimum 3 measurements per square meter required. Measurement only after minimum 1 week drying time.
  • Area: Haftung des Beschichtungssystems zu Substrat unzureichend (Abloesung)
    Check: Perform pull-off adhesion test (ASTM D4541) with portable adhesion tester: glue dolly to dry layer (≥1 week cure), increase perpendicular tensile force at constant rate until failure. Determine reading in MPa/PSI. Classify failure mode (adhesion failure at substrate, layer-to-layer failure or substrate failure). Minimum 5 test points per application area.
  • Area: Surface profile (anchor pattern) insufficient for adhesion after blast cleaning
    Check: Measure surface profile per ASTM D4417 (Method B: depth micrometer, Method C: replica tape) BEFORE application. Determine Mean Maximum Profile (h_max) by averaging at least 20 peak-to-valley measurements. Required profile typically 50–75 µm for epoxy systems. If too shallow (<50 µm): blast clean again; if too deep (>75 µm): not acceptable.
  • Area: Fehlstellen (Pinholes/Holidays) in der Beschichtung — Korrosionsnukleation
    Check: Deploy holiday/pinhole detector: low-voltage wet brush method (≤500 µm thickness) or high-voltage spark tester (>250 µm). Move electrode surface step-by-step over all surfaces. Alarm/needle indication shows defect. Mark and document. Alternatively: UV-pigment method for large-area tank testing in darkness.
  • Area: Application conditions (temperature/humidity/dew point) violate PSPC requirements — adhesion and cure failures
    Check: During application and cure continuously document: steel temperature (surface temperature with infrared pyrometer), relative humidity (hygrometer), dew point. Ensure steel temperature is at least 3°C above dew point (condensation risk). Air temperature between 2–43°C (Seaguard 5000 HS: 35–110°F). Document in inspection record with date/time.
  • Area: Visuelle Maengel: Glanzgrad, Farbkontinuitaet, Kratzer, Blasen, Schalebildung, Kratzer
    Check: Inspect visually against reference standard per ASTM D4141 Method C (gloss/color). Scan surfaces for weak points: scratches, blisters (pores), shell formation, scratches, color spots. Measure defect area with calipers and document photographically. Some surface defects (small scratches <5 mm²) are acceptable per PSPC tolerances; blisters or shell formation = rework required.

Type universal inspection/maintenance points for Paint & Coating Systems (Sherwin-Williams Marine, Mega-Schwarm 2026-06). Per-model specs not auto-populated.

SW BT Aft Peak
Position
Aft Peak
Pspc compliant
ja
Technical Specifications
Volume Solids (Seaguard 5000 HS)
73 ± 2% gemischt
Mischverhaeltnis
1:1 by volume (two-component)
VOC (EPA Method 24)
<250 g/L
Nenndicke DFT
0,1778–0,2540 mm (7–10 mils)
PSPC 90/10 DFT-Regel
90% der Messungen ≥ NDFT; 10% mindestens ≥ 0,9×NDFT (typisch 320 µm für Ballasttank)
Oberflächenprofil (nach Blastdreinigung)
ISO 8501-3 P2; minimum 2 mm rounded edge after grinding
Product Lines
  • Seaguard 5000 HS (High-Solids Epoxy Primer)
  • Seaguard Marine Epoxy
  • Pro-Line Series (Pro-Glo Xpress, Pro-Line 4800, Pro-Line 3000)
  • Sher-Loxane 800 (Epoxy-Polyurethane Hybrid)
  • Seaguard 1000
  • Seaguard 6100
🎯 Application Area
Application data not yet recorded.
Common Failures & Inspection Points
  • Area: Dry Film Thickness (DFT) does not meet PSPC 90/10 requirement
    Check: Perform DFT measurement with calibrated wet film thickness gauge (ASTM D7091): 90% of all measurements ≥ nominal DFT; maximum 10% may be between 0.9×NDFT and NDFT. Minimum 3 measurements per square meter required. Measurement only after minimum 1 week drying time.
  • Area: Haftung des Beschichtungssystems zu Substrat unzureichend (Abloesung)
    Check: Perform pull-off adhesion test (ASTM D4541) with portable adhesion tester: glue dolly to dry layer (≥1 week cure), increase perpendicular tensile force at constant rate until failure. Determine reading in MPa/PSI. Classify failure mode (adhesion failure at substrate, layer-to-layer failure or substrate failure). Minimum 5 test points per application area.
  • Area: Surface profile (anchor pattern) insufficient for adhesion after blast cleaning
    Check: Measure surface profile per ASTM D4417 (Method B: depth micrometer, Method C: replica tape) BEFORE application. Determine Mean Maximum Profile (h_max) by averaging at least 20 peak-to-valley measurements. Required profile typically 50–75 µm for epoxy systems. If too shallow (<50 µm): blast clean again; if too deep (>75 µm): not acceptable.
  • Area: Fehlstellen (Pinholes/Holidays) in der Beschichtung — Korrosionsnukleation
    Check: Deploy holiday/pinhole detector: low-voltage wet brush method (≤500 µm thickness) or high-voltage spark tester (>250 µm). Move electrode surface step-by-step over all surfaces. Alarm/needle indication shows defect. Mark and document. Alternatively: UV-pigment method for large-area tank testing in darkness.
  • Area: Application conditions (temperature/humidity/dew point) violate PSPC requirements — adhesion and cure failures
    Check: During application and cure continuously document: steel temperature (surface temperature with infrared pyrometer), relative humidity (hygrometer), dew point. Ensure steel temperature is at least 3°C above dew point (condensation risk). Air temperature between 2–43°C (Seaguard 5000 HS: 35–110°F). Document in inspection record with date/time.
  • Area: Visuelle Maengel: Glanzgrad, Farbkontinuitaet, Kratzer, Blasen, Schalebildung, Kratzer
    Check: Inspect visually against reference standard per ASTM D4141 Method C (gloss/color). Scan surfaces for weak points: scratches, blisters (pores), shell formation, scratches, color spots. Measure defect area with calipers and document photographically. Some surface defects (small scratches <5 mm²) are acceptable per PSPC tolerances; blisters or shell formation = rework required.

Type universal inspection/maintenance points for Paint & Coating Systems (Sherwin-Williams Marine, Mega-Schwarm 2026-06). Per-model specs not auto-populated.

SW BT Upper Wing
Position
Upper Wing
Pspc compliant
ja
Technical Specifications
Volume Solids (Seaguard 5000 HS)
73 ± 2% gemischt
Mischverhaeltnis
1:1 by volume (two-component)
VOC (EPA Method 24)
<250 g/L
Nenndicke DFT
0,1778–0,2540 mm (7–10 mils)
PSPC 90/10 DFT-Regel
90% der Messungen ≥ NDFT; 10% mindestens ≥ 0,9×NDFT (typisch 320 µm für Ballasttank)
Oberflächenprofil (nach Blastdreinigung)
ISO 8501-3 P2; minimum 2 mm rounded edge after grinding
Product Lines
  • Seaguard 5000 HS (High-Solids Epoxy Primer)
  • Seaguard Marine Epoxy
  • Pro-Line Series (Pro-Glo Xpress, Pro-Line 4800, Pro-Line 3000)
  • Sher-Loxane 800 (Epoxy-Polyurethane Hybrid)
  • Seaguard 1000
  • Seaguard 6100
🎯 Application Area
Application data not yet recorded.
Common Failures & Inspection Points
  • Area: Dry Film Thickness (DFT) does not meet PSPC 90/10 requirement
    Check: Perform DFT measurement with calibrated wet film thickness gauge (ASTM D7091): 90% of all measurements ≥ nominal DFT; maximum 10% may be between 0.9×NDFT and NDFT. Minimum 3 measurements per square meter required. Measurement only after minimum 1 week drying time.
  • Area: Haftung des Beschichtungssystems zu Substrat unzureichend (Abloesung)
    Check: Perform pull-off adhesion test (ASTM D4541) with portable adhesion tester: glue dolly to dry layer (≥1 week cure), increase perpendicular tensile force at constant rate until failure. Determine reading in MPa/PSI. Classify failure mode (adhesion failure at substrate, layer-to-layer failure or substrate failure). Minimum 5 test points per application area.
  • Area: Surface profile (anchor pattern) insufficient for adhesion after blast cleaning
    Check: Measure surface profile per ASTM D4417 (Method B: depth micrometer, Method C: replica tape) BEFORE application. Determine Mean Maximum Profile (h_max) by averaging at least 20 peak-to-valley measurements. Required profile typically 50–75 µm for epoxy systems. If too shallow (<50 µm): blast clean again; if too deep (>75 µm): not acceptable.
  • Area: Fehlstellen (Pinholes/Holidays) in der Beschichtung — Korrosionsnukleation
    Check: Deploy holiday/pinhole detector: low-voltage wet brush method (≤500 µm thickness) or high-voltage spark tester (>250 µm). Move electrode surface step-by-step over all surfaces. Alarm/needle indication shows defect. Mark and document. Alternatively: UV-pigment method for large-area tank testing in darkness.
  • Area: Application conditions (temperature/humidity/dew point) violate PSPC requirements — adhesion and cure failures
    Check: During application and cure continuously document: steel temperature (surface temperature with infrared pyrometer), relative humidity (hygrometer), dew point. Ensure steel temperature is at least 3°C above dew point (condensation risk). Air temperature between 2–43°C (Seaguard 5000 HS: 35–110°F). Document in inspection record with date/time.
  • Area: Visuelle Maengel: Glanzgrad, Farbkontinuitaet, Kratzer, Blasen, Schalebildung, Kratzer
    Check: Inspect visually against reference standard per ASTM D4141 Method C (gloss/color). Scan surfaces for weak points: scratches, blisters (pores), shell formation, scratches, color spots. Measure defect area with calipers and document photographically. Some surface defects (small scratches <5 mm²) are acceptable per PSPC tolerances; blisters or shell formation = rework required.

Type universal inspection/maintenance points for Paint & Coating Systems (Sherwin-Williams Marine, Mega-Schwarm 2026-06). Per-model specs not auto-populated.

Sherwin-Williams Marine Coal Tar Epoxy
Type
Coal Tar Epoxy
Technical Specifications
Volume Solids (Seaguard 5000 HS)
73 ± 2% gemischt
Mischverhaeltnis
1:1 by volume (two-component)
VOC (EPA Method 24)
<250 g/L
Nenndicke DFT
0,1778–0,2540 mm (7–10 mils)
PSPC 90/10 DFT-Regel
90% der Messungen ≥ NDFT; 10% mindestens ≥ 0,9×NDFT (typisch 320 µm für Ballasttank)
Oberflächenprofil (nach Blastdreinigung)
ISO 8501-3 P2; minimum 2 mm rounded edge after grinding
Product Lines
  • Seaguard 5000 HS (High-Solids Epoxy Primer)
  • Seaguard Marine Epoxy
  • Pro-Line Series (Pro-Glo Xpress, Pro-Line 4800, Pro-Line 3000)
  • Sher-Loxane 800 (Epoxy-Polyurethane Hybrid)
  • Seaguard 1000
  • Seaguard 6100
🎯 Application Area
Application data not yet recorded.
Common Failures & Inspection Points
  • Area: Dry Film Thickness (DFT) does not meet PSPC 90/10 requirement
    Check: Perform DFT measurement with calibrated wet film thickness gauge (ASTM D7091): 90% of all measurements ≥ nominal DFT; maximum 10% may be between 0.9×NDFT and NDFT. Minimum 3 measurements per square meter required. Measurement only after minimum 1 week drying time.
  • Area: Haftung des Beschichtungssystems zu Substrat unzureichend (Abloesung)
    Check: Perform pull-off adhesion test (ASTM D4541) with portable adhesion tester: glue dolly to dry layer (≥1 week cure), increase perpendicular tensile force at constant rate until failure. Determine reading in MPa/PSI. Classify failure mode (adhesion failure at substrate, layer-to-layer failure or substrate failure). Minimum 5 test points per application area.
  • Area: Surface profile (anchor pattern) insufficient for adhesion after blast cleaning
    Check: Measure surface profile per ASTM D4417 (Method B: depth micrometer, Method C: replica tape) BEFORE application. Determine Mean Maximum Profile (h_max) by averaging at least 20 peak-to-valley measurements. Required profile typically 50–75 µm for epoxy systems. If too shallow (<50 µm): blast clean again; if too deep (>75 µm): not acceptable.
  • Area: Fehlstellen (Pinholes/Holidays) in der Beschichtung — Korrosionsnukleation
    Check: Deploy holiday/pinhole detector: low-voltage wet brush method (≤500 µm thickness) or high-voltage spark tester (>250 µm). Move electrode surface step-by-step over all surfaces. Alarm/needle indication shows defect. Mark and document. Alternatively: UV-pigment method for large-area tank testing in darkness.
  • Area: Application conditions (temperature/humidity/dew point) violate PSPC requirements — adhesion and cure failures
    Check: During application and cure continuously document: steel temperature (surface temperature with infrared pyrometer), relative humidity (hygrometer), dew point. Ensure steel temperature is at least 3°C above dew point (condensation risk). Air temperature between 2–43°C (Seaguard 5000 HS: 35–110°F). Document in inspection record with date/time.
  • Area: Visuelle Maengel: Glanzgrad, Farbkontinuitaet, Kratzer, Blasen, Schalebildung, Kratzer
    Check: Inspect visually against reference standard per ASTM D4141 Method C (gloss/color). Scan surfaces for weak points: scratches, blisters (pores), shell formation, scratches, color spots. Measure defect area with calipers and document photographically. Some surface defects (small scratches <5 mm²) are acceptable per PSPC tolerances; blisters or shell formation = rework required.

Type universal inspection/maintenance points for Paint & Coating Systems (Sherwin-Williams Marine, Mega-Schwarm 2026-06). Per-model specs not auto-populated.

Sherwin-Williams Marine Potable Water Tank-C
Application
Potable Water Tank
Technical Specifications
Volume Solids (Seaguard 5000 HS)
73 ± 2% gemischt
Mischverhaeltnis
1:1 by volume (two-component)
VOC (EPA Method 24)
<250 g/L
Nenndicke DFT
0,1778–0,2540 mm (7–10 mils)
PSPC 90/10 DFT-Regel
90% der Messungen ≥ NDFT; 10% mindestens ≥ 0,9×NDFT (typisch 320 µm für Ballasttank)
Oberflächenprofil (nach Blastdreinigung)
ISO 8501-3 P2; minimum 2 mm rounded edge after grinding
Product Lines
  • Seaguard 5000 HS (High-Solids Epoxy Primer)
  • Seaguard Marine Epoxy
  • Pro-Line Series (Pro-Glo Xpress, Pro-Line 4800, Pro-Line 3000)
  • Sher-Loxane 800 (Epoxy-Polyurethane Hybrid)
  • Seaguard 1000
  • Seaguard 6100
🎯 Application Area
Application data not yet recorded.
Common Failures & Inspection Points
  • Area: Dry Film Thickness (DFT) does not meet PSPC 90/10 requirement
    Check: Perform DFT measurement with calibrated wet film thickness gauge (ASTM D7091): 90% of all measurements ≥ nominal DFT; maximum 10% may be between 0.9×NDFT and NDFT. Minimum 3 measurements per square meter required. Measurement only after minimum 1 week drying time.
  • Area: Haftung des Beschichtungssystems zu Substrat unzureichend (Abloesung)
    Check: Perform pull-off adhesion test (ASTM D4541) with portable adhesion tester: glue dolly to dry layer (≥1 week cure), increase perpendicular tensile force at constant rate until failure. Determine reading in MPa/PSI. Classify failure mode (adhesion failure at substrate, layer-to-layer failure or substrate failure). Minimum 5 test points per application area.
  • Area: Surface profile (anchor pattern) insufficient for adhesion after blast cleaning
    Check: Measure surface profile per ASTM D4417 (Method B: depth micrometer, Method C: replica tape) BEFORE application. Determine Mean Maximum Profile (h_max) by averaging at least 20 peak-to-valley measurements. Required profile typically 50–75 µm for epoxy systems. If too shallow (<50 µm): blast clean again; if too deep (>75 µm): not acceptable.
  • Area: Fehlstellen (Pinholes/Holidays) in der Beschichtung — Korrosionsnukleation
    Check: Deploy holiday/pinhole detector: low-voltage wet brush method (≤500 µm thickness) or high-voltage spark tester (>250 µm). Move electrode surface step-by-step over all surfaces. Alarm/needle indication shows defect. Mark and document. Alternatively: UV-pigment method for large-area tank testing in darkness.
  • Area: Application conditions (temperature/humidity/dew point) violate PSPC requirements — adhesion and cure failures
    Check: During application and cure continuously document: steel temperature (surface temperature with infrared pyrometer), relative humidity (hygrometer), dew point. Ensure steel temperature is at least 3°C above dew point (condensation risk). Air temperature between 2–43°C (Seaguard 5000 HS: 35–110°F). Document in inspection record with date/time.
  • Area: Visuelle Maengel: Glanzgrad, Farbkontinuitaet, Kratzer, Blasen, Schalebildung, Kratzer
    Check: Inspect visually against reference standard per ASTM D4141 Method C (gloss/color). Scan surfaces for weak points: scratches, blisters (pores), shell formation, scratches, color spots. Measure defect area with calipers and document photographically. Some surface defects (small scratches <5 mm²) are acceptable per PSPC tolerances; blisters or shell formation = rework required.

Type universal inspection/maintenance points for Paint & Coating Systems (Sherwin-Williams Marine, Mega-Schwarm 2026-06). Per-model specs not auto-populated.

Dura-Plate UHS BT
Product Line
Dura-Plate
Coating Type
tank
Application Method
airless spray
Dft (µm)
350
Voc (g/l)
140
Overcoating Interval (h)
12
Technical Specifications
Volume Solids (Seaguard 5000 HS)
73 ± 2% gemischt
Mischverhaeltnis
1:1 by volume (two-component)
VOC (EPA Method 24)
<250 g/L
Nenndicke DFT
0,1778–0,2540 mm (7–10 mils)
PSPC 90/10 DFT-Regel
90% der Messungen ≥ NDFT; 10% mindestens ≥ 0,9×NDFT (typisch 320 µm für Ballasttank)
Oberflächenprofil (nach Blastdreinigung)
ISO 8501-3 P2; minimum 2 mm rounded edge after grinding
Product Lines
  • Seaguard 5000 HS (High-Solids Epoxy Primer)
  • Seaguard Marine Epoxy
  • Pro-Line Series (Pro-Glo Xpress, Pro-Line 4800, Pro-Line 3000)
  • Sher-Loxane 800 (Epoxy-Polyurethane Hybrid)
  • Seaguard 1000
  • Seaguard 6100
🎯 Application Area
Application data not yet recorded.
Common Failures & Inspection Points
  • Area: Dry Film Thickness (DFT) does not meet PSPC 90/10 requirement
    Check: Perform DFT measurement with calibrated wet film thickness gauge (ASTM D7091): 90% of all measurements ≥ nominal DFT; maximum 10% may be between 0.9×NDFT and NDFT. Minimum 3 measurements per square meter required. Measurement only after minimum 1 week drying time.
  • Area: Haftung des Beschichtungssystems zu Substrat unzureichend (Abloesung)
    Check: Perform pull-off adhesion test (ASTM D4541) with portable adhesion tester: glue dolly to dry layer (≥1 week cure), increase perpendicular tensile force at constant rate until failure. Determine reading in MPa/PSI. Classify failure mode (adhesion failure at substrate, layer-to-layer failure or substrate failure). Minimum 5 test points per application area.
  • Area: Surface profile (anchor pattern) insufficient for adhesion after blast cleaning
    Check: Measure surface profile per ASTM D4417 (Method B: depth micrometer, Method C: replica tape) BEFORE application. Determine Mean Maximum Profile (h_max) by averaging at least 20 peak-to-valley measurements. Required profile typically 50–75 µm for epoxy systems. If too shallow (<50 µm): blast clean again; if too deep (>75 µm): not acceptable.
  • Area: Fehlstellen (Pinholes/Holidays) in der Beschichtung — Korrosionsnukleation
    Check: Deploy holiday/pinhole detector: low-voltage wet brush method (≤500 µm thickness) or high-voltage spark tester (>250 µm). Move electrode surface step-by-step over all surfaces. Alarm/needle indication shows defect. Mark and document. Alternatively: UV-pigment method for large-area tank testing in darkness.
  • Area: Application conditions (temperature/humidity/dew point) violate PSPC requirements — adhesion and cure failures
    Check: During application and cure continuously document: steel temperature (surface temperature with infrared pyrometer), relative humidity (hygrometer), dew point. Ensure steel temperature is at least 3°C above dew point (condensation risk). Air temperature between 2–43°C (Seaguard 5000 HS: 35–110°F). Document in inspection record with date/time.
  • Area: Visuelle Maengel: Glanzgrad, Farbkontinuitaet, Kratzer, Blasen, Schalebildung, Kratzer
    Check: Inspect visually against reference standard per ASTM D4141 Method C (gloss/color). Scan surfaces for weak points: scratches, blisters (pores), shell formation, scratches, color spots. Measure defect area with calipers and document photographically. Some surface defects (small scratches <5 mm²) are acceptable per PSPC tolerances; blisters or shell formation = rework required.

Type universal inspection/maintenance points for Paint & Coating Systems (Sherwin-Williams Marine, Mega-Schwarm 2026-06). Per-model specs not auto-populated.

Dura-Plate PSPC Stripe Coat
Product Line
Dura-Plate PSPC
Coating Type
tank
Imo pspc compliant
ja
Coat layer
Stripe Coat
Application Method
airless spray
Dft (µm)
160
Voc (g/l)
190
Overcoating Interval (h)
8
Technical Specifications
Volume Solids (Seaguard 5000 HS)
73 ± 2% gemischt
Mischverhaeltnis
1:1 by volume (two-component)
VOC (EPA Method 24)
<250 g/L
Nenndicke DFT
0,1778–0,2540 mm (7–10 mils)
PSPC 90/10 DFT-Regel
90% der Messungen ≥ NDFT; 10% mindestens ≥ 0,9×NDFT (typisch 320 µm für Ballasttank)
Oberflächenprofil (nach Blastdreinigung)
ISO 8501-3 P2; minimum 2 mm rounded edge after grinding
Product Lines
  • Seaguard 5000 HS (High-Solids Epoxy Primer)
  • Seaguard Marine Epoxy
  • Pro-Line Series (Pro-Glo Xpress, Pro-Line 4800, Pro-Line 3000)
  • Sher-Loxane 800 (Epoxy-Polyurethane Hybrid)
  • Seaguard 1000
  • Seaguard 6100
🎯 Application Area
Application data not yet recorded.
Common Failures & Inspection Points
  • Area: Dry Film Thickness (DFT) does not meet PSPC 90/10 requirement
    Check: Perform DFT measurement with calibrated wet film thickness gauge (ASTM D7091): 90% of all measurements ≥ nominal DFT; maximum 10% may be between 0.9×NDFT and NDFT. Minimum 3 measurements per square meter required. Measurement only after minimum 1 week drying time.
  • Area: Haftung des Beschichtungssystems zu Substrat unzureichend (Abloesung)
    Check: Perform pull-off adhesion test (ASTM D4541) with portable adhesion tester: glue dolly to dry layer (≥1 week cure), increase perpendicular tensile force at constant rate until failure. Determine reading in MPa/PSI. Classify failure mode (adhesion failure at substrate, layer-to-layer failure or substrate failure). Minimum 5 test points per application area.
  • Area: Surface profile (anchor pattern) insufficient for adhesion after blast cleaning
    Check: Measure surface profile per ASTM D4417 (Method B: depth micrometer, Method C: replica tape) BEFORE application. Determine Mean Maximum Profile (h_max) by averaging at least 20 peak-to-valley measurements. Required profile typically 50–75 µm for epoxy systems. If too shallow (<50 µm): blast clean again; if too deep (>75 µm): not acceptable.
  • Area: Fehlstellen (Pinholes/Holidays) in der Beschichtung — Korrosionsnukleation
    Check: Deploy holiday/pinhole detector: low-voltage wet brush method (≤500 µm thickness) or high-voltage spark tester (>250 µm). Move electrode surface step-by-step over all surfaces. Alarm/needle indication shows defect. Mark and document. Alternatively: UV-pigment method for large-area tank testing in darkness.
  • Area: Application conditions (temperature/humidity/dew point) violate PSPC requirements — adhesion and cure failures
    Check: During application and cure continuously document: steel temperature (surface temperature with infrared pyrometer), relative humidity (hygrometer), dew point. Ensure steel temperature is at least 3°C above dew point (condensation risk). Air temperature between 2–43°C (Seaguard 5000 HS: 35–110°F). Document in inspection record with date/time.
  • Area: Visuelle Maengel: Glanzgrad, Farbkontinuitaet, Kratzer, Blasen, Schalebildung, Kratzer
    Check: Inspect visually against reference standard per ASTM D4141 Method C (gloss/color). Scan surfaces for weak points: scratches, blisters (pores), shell formation, scratches, color spots. Measure defect area with calipers and document photographically. Some surface defects (small scratches <5 mm²) are acceptable per PSPC tolerances; blisters or shell formation = rework required.

Type universal inspection/maintenance points for Paint & Coating Systems (Sherwin-Williams Marine, Mega-Schwarm 2026-06). Per-model specs not auto-populated.

Dura-Plate PSPC 1st Full Coat
Product Line
Dura-Plate PSPC
Coating Type
tank
Imo pspc compliant
ja
Coat layer
1st Full Coat
Application Method
airless spray
Dft (µm)
160
Voc (g/l)
190
Overcoating Interval (h)
8
Technical Specifications
Volume Solids (Seaguard 5000 HS)
73 ± 2% gemischt
Mischverhaeltnis
1:1 by volume (two-component)
VOC (EPA Method 24)
<250 g/L
Nenndicke DFT
0,1778–0,2540 mm (7–10 mils)
PSPC 90/10 DFT-Regel
90% der Messungen ≥ NDFT; 10% mindestens ≥ 0,9×NDFT (typisch 320 µm für Ballasttank)
Oberflächenprofil (nach Blastdreinigung)
ISO 8501-3 P2; minimum 2 mm rounded edge after grinding
Product Lines
  • Seaguard 5000 HS (High-Solids Epoxy Primer)
  • Seaguard Marine Epoxy
  • Pro-Line Series (Pro-Glo Xpress, Pro-Line 4800, Pro-Line 3000)
  • Sher-Loxane 800 (Epoxy-Polyurethane Hybrid)
  • Seaguard 1000
  • Seaguard 6100
🎯 Application Area
Application data not yet recorded.
Common Failures & Inspection Points
  • Area: Dry Film Thickness (DFT) does not meet PSPC 90/10 requirement
    Check: Perform DFT measurement with calibrated wet film thickness gauge (ASTM D7091): 90% of all measurements ≥ nominal DFT; maximum 10% may be between 0.9×NDFT and NDFT. Minimum 3 measurements per square meter required. Measurement only after minimum 1 week drying time.
  • Area: Haftung des Beschichtungssystems zu Substrat unzureichend (Abloesung)
    Check: Perform pull-off adhesion test (ASTM D4541) with portable adhesion tester: glue dolly to dry layer (≥1 week cure), increase perpendicular tensile force at constant rate until failure. Determine reading in MPa/PSI. Classify failure mode (adhesion failure at substrate, layer-to-layer failure or substrate failure). Minimum 5 test points per application area.
  • Area: Surface profile (anchor pattern) insufficient for adhesion after blast cleaning
    Check: Measure surface profile per ASTM D4417 (Method B: depth micrometer, Method C: replica tape) BEFORE application. Determine Mean Maximum Profile (h_max) by averaging at least 20 peak-to-valley measurements. Required profile typically 50–75 µm for epoxy systems. If too shallow (<50 µm): blast clean again; if too deep (>75 µm): not acceptable.
  • Area: Fehlstellen (Pinholes/Holidays) in der Beschichtung — Korrosionsnukleation
    Check: Deploy holiday/pinhole detector: low-voltage wet brush method (≤500 µm thickness) or high-voltage spark tester (>250 µm). Move electrode surface step-by-step over all surfaces. Alarm/needle indication shows defect. Mark and document. Alternatively: UV-pigment method for large-area tank testing in darkness.
  • Area: Application conditions (temperature/humidity/dew point) violate PSPC requirements — adhesion and cure failures
    Check: During application and cure continuously document: steel temperature (surface temperature with infrared pyrometer), relative humidity (hygrometer), dew point. Ensure steel temperature is at least 3°C above dew point (condensation risk). Air temperature between 2–43°C (Seaguard 5000 HS: 35–110°F). Document in inspection record with date/time.
  • Area: Visuelle Maengel: Glanzgrad, Farbkontinuitaet, Kratzer, Blasen, Schalebildung, Kratzer
    Check: Inspect visually against reference standard per ASTM D4141 Method C (gloss/color). Scan surfaces for weak points: scratches, blisters (pores), shell formation, scratches, color spots. Measure defect area with calipers and document photographically. Some surface defects (small scratches <5 mm²) are acceptable per PSPC tolerances; blisters or shell formation = rework required.

Type universal inspection/maintenance points for Paint & Coating Systems (Sherwin-Williams Marine, Mega-Schwarm 2026-06). Per-model specs not auto-populated.

Dura-Plate PSPC 2nd Full Coat
Product Line
Dura-Plate PSPC
Coating Type
tank
Imo pspc compliant
ja
Coat layer
2nd Full Coat
Application Method
airless spray
Dft (µm)
160
Voc (g/l)
190
Overcoating Interval (h)
8
Technical Specifications
Volume Solids (Seaguard 5000 HS)
73 ± 2% gemischt
Mischverhaeltnis
1:1 by volume (two-component)
VOC (EPA Method 24)
<250 g/L
Nenndicke DFT
0,1778–0,2540 mm (7–10 mils)
PSPC 90/10 DFT-Regel
90% der Messungen ≥ NDFT; 10% mindestens ≥ 0,9×NDFT (typisch 320 µm für Ballasttank)
Oberflächenprofil (nach Blastdreinigung)
ISO 8501-3 P2; minimum 2 mm rounded edge after grinding
Product Lines
  • Seaguard 5000 HS (High-Solids Epoxy Primer)
  • Seaguard Marine Epoxy
  • Pro-Line Series (Pro-Glo Xpress, Pro-Line 4800, Pro-Line 3000)
  • Sher-Loxane 800 (Epoxy-Polyurethane Hybrid)
  • Seaguard 1000
  • Seaguard 6100
🎯 Application Area
Application data not yet recorded.
Common Failures & Inspection Points
  • Area: Dry Film Thickness (DFT) does not meet PSPC 90/10 requirement
    Check: Perform DFT measurement with calibrated wet film thickness gauge (ASTM D7091): 90% of all measurements ≥ nominal DFT; maximum 10% may be between 0.9×NDFT and NDFT. Minimum 3 measurements per square meter required. Measurement only after minimum 1 week drying time.
  • Area: Haftung des Beschichtungssystems zu Substrat unzureichend (Abloesung)
    Check: Perform pull-off adhesion test (ASTM D4541) with portable adhesion tester: glue dolly to dry layer (≥1 week cure), increase perpendicular tensile force at constant rate until failure. Determine reading in MPa/PSI. Classify failure mode (adhesion failure at substrate, layer-to-layer failure or substrate failure). Minimum 5 test points per application area.
  • Area: Surface profile (anchor pattern) insufficient for adhesion after blast cleaning
    Check: Measure surface profile per ASTM D4417 (Method B: depth micrometer, Method C: replica tape) BEFORE application. Determine Mean Maximum Profile (h_max) by averaging at least 20 peak-to-valley measurements. Required profile typically 50–75 µm for epoxy systems. If too shallow (<50 µm): blast clean again; if too deep (>75 µm): not acceptable.
  • Area: Fehlstellen (Pinholes/Holidays) in der Beschichtung — Korrosionsnukleation
    Check: Deploy holiday/pinhole detector: low-voltage wet brush method (≤500 µm thickness) or high-voltage spark tester (>250 µm). Move electrode surface step-by-step over all surfaces. Alarm/needle indication shows defect. Mark and document. Alternatively: UV-pigment method for large-area tank testing in darkness.
  • Area: Application conditions (temperature/humidity/dew point) violate PSPC requirements — adhesion and cure failures
    Check: During application and cure continuously document: steel temperature (surface temperature with infrared pyrometer), relative humidity (hygrometer), dew point. Ensure steel temperature is at least 3°C above dew point (condensation risk). Air temperature between 2–43°C (Seaguard 5000 HS: 35–110°F). Document in inspection record with date/time.
  • Area: Visuelle Maengel: Glanzgrad, Farbkontinuitaet, Kratzer, Blasen, Schalebildung, Kratzer
    Check: Inspect visually against reference standard per ASTM D4141 Method C (gloss/color). Scan surfaces for weak points: scratches, blisters (pores), shell formation, scratches, color spots. Measure defect area with calipers and document photographically. Some surface defects (small scratches <5 mm²) are acceptable per PSPC tolerances; blisters or shell formation = rework required.

Type universal inspection/maintenance points for Paint & Coating Systems (Sherwin-Williams Marine, Mega-Schwarm 2026-06). Per-model specs not auto-populated.

Dura-Plate PSPC 6000 IMO PSPC System
Product Line
Dura-Plate PSPC 6000
Coating Type
tank
Imo pspc compliant
ja
Application Method
airless spray
Dft (µm)
320
Voc (g/l)
180
Technical Specifications
Volume Solids (Seaguard 5000 HS)
73 ± 2% gemischt
Mischverhaeltnis
1:1 by volume (two-component)
VOC (EPA Method 24)
<250 g/L
Nenndicke DFT
0,1778–0,2540 mm (7–10 mils)
PSPC 90/10 DFT-Regel
90% der Messungen ≥ NDFT; 10% mindestens ≥ 0,9×NDFT (typisch 320 µm für Ballasttank)
Oberflächenprofil (nach Blastdreinigung)
ISO 8501-3 P2; minimum 2 mm rounded edge after grinding
Product Lines
  • Seaguard 5000 HS (High-Solids Epoxy Primer)
  • Seaguard Marine Epoxy
  • Pro-Line Series (Pro-Glo Xpress, Pro-Line 4800, Pro-Line 3000)
  • Sher-Loxane 800 (Epoxy-Polyurethane Hybrid)
  • Seaguard 1000
  • Seaguard 6100
🎯 Application Area
Application data not yet recorded.
Common Failures & Inspection Points
  • Area: Dry Film Thickness (DFT) does not meet PSPC 90/10 requirement
    Check: Perform DFT measurement with calibrated wet film thickness gauge (ASTM D7091): 90% of all measurements ≥ nominal DFT; maximum 10% may be between 0.9×NDFT and NDFT. Minimum 3 measurements per square meter required. Measurement only after minimum 1 week drying time.
  • Area: Haftung des Beschichtungssystems zu Substrat unzureichend (Abloesung)
    Check: Perform pull-off adhesion test (ASTM D4541) with portable adhesion tester: glue dolly to dry layer (≥1 week cure), increase perpendicular tensile force at constant rate until failure. Determine reading in MPa/PSI. Classify failure mode (adhesion failure at substrate, layer-to-layer failure or substrate failure). Minimum 5 test points per application area.
  • Area: Surface profile (anchor pattern) insufficient for adhesion after blast cleaning
    Check: Measure surface profile per ASTM D4417 (Method B: depth micrometer, Method C: replica tape) BEFORE application. Determine Mean Maximum Profile (h_max) by averaging at least 20 peak-to-valley measurements. Required profile typically 50–75 µm for epoxy systems. If too shallow (<50 µm): blast clean again; if too deep (>75 µm): not acceptable.
  • Area: Fehlstellen (Pinholes/Holidays) in der Beschichtung — Korrosionsnukleation
    Check: Deploy holiday/pinhole detector: low-voltage wet brush method (≤500 µm thickness) or high-voltage spark tester (>250 µm). Move electrode surface step-by-step over all surfaces. Alarm/needle indication shows defect. Mark and document. Alternatively: UV-pigment method for large-area tank testing in darkness.
  • Area: Application conditions (temperature/humidity/dew point) violate PSPC requirements — adhesion and cure failures
    Check: During application and cure continuously document: steel temperature (surface temperature with infrared pyrometer), relative humidity (hygrometer), dew point. Ensure steel temperature is at least 3°C above dew point (condensation risk). Air temperature between 2–43°C (Seaguard 5000 HS: 35–110°F). Document in inspection record with date/time.
  • Area: Visuelle Maengel: Glanzgrad, Farbkontinuitaet, Kratzer, Blasen, Schalebildung, Kratzer
    Check: Inspect visually against reference standard per ASTM D4141 Method C (gloss/color). Scan surfaces for weak points: scratches, blisters (pores), shell formation, scratches, color spots. Measure defect area with calipers and document photographically. Some surface defects (small scratches <5 mm²) are acceptable per PSPC tolerances; blisters or shell formation = rework required.

Type universal inspection/maintenance points for Paint & Coating Systems (Sherwin-Williams Marine, Mega-Schwarm 2026-06). Per-model specs not auto-populated.

Nippon Paint Marine

12
Neoguard Super BT unverified
Type
Ballast Tank Epoxy
Pspc compliant
ja
🎯 Application Area
Application: Hull, ballast tank, cargo tank, deck, superstructure and structural corrosion protection.
Common Failures & Inspection Points
  • Poor surface preparation causes loss of adhesion, blistering or early coating breakdown
  • Incorrect application or curing conditions cause runs, pinholes, incomplete cure or premature wear
  • Mechanical damage exposes the substrate and leads to localized corrosion
  • Chemical, cargo or immersion incompatibility causes softening, swelling, discoloration or delamination
  • Incorrect mixing or overcoating practice causes poor cure or intercoat adhesion
Service: Inspect coating continuity, adhesion, cracking, blistering, rusting and mechanical damage. Review surface preparation and application records where available and determine whether failure is local or systemic. Repair only with compatible products and approved preparation. Refer to the coating manufacturer's documentation for the exact figure for film thickness, mixing, cure and environmental limits.
Spare Parts: Keep compatible touch-up coating, approved thinner or cleaner, repair primers and application consumables in accordance with the vessel coating maintenance plan.
NPM BT Double Bottom unverified
Position
Double Bottom
Pspc compliant
ja
🎯 Application Area
Application: Corrosion, fouling, chemical, slip or fire protection of hull, tanks, decks and machinery spaces according to the listed coating system.
Common Failures & Inspection Points
  • Blistering caused by moisture, osmotic contamination or poor surface preparation, resulting in raised bubbles and localized coating loss
  • Delamination caused by inadequate surface preparation, contamination or incompatible overcoating, resulting in peeling or loss of adhesion
  • Underfilm corrosion caused by coating damage, holidays or poor edge coverage, resulting in rust staining and progressive coating breakdown
  • Cracking or embrittlement caused by excessive film build, aging or substrate movement, resulting in visible cracks and loss of barrier protection
  • Abrasion, impact or chemical attack caused by service exposure, resulting in worn areas, discoloration or exposed substrate
Service: Inspect coated surfaces for blistering, rusting, cracking, peeling, mechanical damage and edge breakdown. Identify and remove the cause of moisture, contamination or chemical attack before local repair. Prepare the substrate and apply compatible repair coats according to the approved coating specification. Maintain batch, mixing, curing and environmental records where required by the vessel coating plan. Pay particular attention to welds, edges, drains and high-abrasion zones. Refer to the manufacturer documentation for the exact figure for surface preparation, dry-film thickness, curing and overcoating requirements.
Spare Parts: Keep compatible primer, intermediate and topcoat materials required by the vessel coating scheme together with approved thinners, repair materials and application consumables. Coating shelf life and storage conditions must be respected. Do not substitute a different coating chemistry without compatibility and approval checks.
NPM BT Side Tank unverified
Position
Side Tank
Pspc compliant
ja
🎯 Application Area
Application: Hull, ballast tank, cargo tank, deck, superstructure and structural corrosion protection.
Common Failures & Inspection Points
  • Poor surface preparation causes loss of adhesion, blistering or early coating breakdown
  • Incorrect application or curing conditions cause runs, pinholes, incomplete cure or premature wear
  • Mechanical damage exposes the substrate and leads to localized corrosion
  • Chemical, cargo or immersion incompatibility causes softening, swelling, discoloration or delamination
  • Incorrect mixing or overcoating practice causes poor cure or intercoat adhesion
Service: Inspect coating continuity, adhesion, cracking, blistering, rusting and mechanical damage. Review surface preparation and application records where available and determine whether failure is local or systemic. Repair only with compatible products and approved preparation. Refer to the coating manufacturer's documentation for the exact figure for film thickness, mixing, cure and environmental limits.
Spare Parts: Keep compatible touch-up coating, approved thinner or cleaner, repair primers and application consumables in accordance with the vessel coating maintenance plan.
NPM BT Fore Peak unverified
Position
Fore Peak
Pspc compliant
ja
🎯 Application Area
Application: Hull, ballast tank, cargo tank, deck, superstructure and structural corrosion protection.
Common Failures & Inspection Points
  • Poor surface preparation causes loss of adhesion, blistering or early coating breakdown
  • Incorrect application or curing conditions cause runs, pinholes, incomplete cure or premature wear
  • Mechanical damage exposes the substrate and leads to localized corrosion
  • Chemical, cargo or immersion incompatibility causes softening, swelling, discoloration or delamination
  • Incorrect mixing or overcoating practice causes poor cure or intercoat adhesion
Service: Inspect coating continuity, adhesion, cracking, blistering, rusting and mechanical damage. Review surface preparation and application records where available and determine whether failure is local or systemic. Repair only with compatible products and approved preparation. Refer to the coating manufacturer's documentation for the exact figure for film thickness, mixing, cure and environmental limits.
Spare Parts: Keep compatible touch-up coating, approved thinner or cleaner, repair primers and application consumables in accordance with the vessel coating maintenance plan.
NPM BT Aft Peak unverified
Position
Aft Peak
Pspc compliant
ja
🎯 Application Area
Application: Hull, ballast tank, cargo tank, deck, superstructure and structural corrosion protection.
Common Failures & Inspection Points
  • Poor surface preparation causes loss of adhesion, blistering or early coating breakdown
  • Incorrect application or curing conditions cause runs, pinholes, incomplete cure or premature wear
  • Mechanical damage exposes the substrate and leads to localized corrosion
  • Chemical, cargo or immersion incompatibility causes softening, swelling, discoloration or delamination
  • Incorrect mixing or overcoating practice causes poor cure or intercoat adhesion
Service: Inspect coating continuity, adhesion, cracking, blistering, rusting and mechanical damage. Review surface preparation and application records where available and determine whether failure is local or systemic. Repair only with compatible products and approved preparation. Refer to the coating manufacturer's documentation for the exact figure for film thickness, mixing, cure and environmental limits.
Spare Parts: Keep compatible touch-up coating, approved thinner or cleaner, repair primers and application consumables in accordance with the vessel coating maintenance plan.
NPM BT Upper Wing unverified
Position
Upper Wing
Pspc compliant
ja
🎯 Application Area
Application: Corrosion, fouling, chemical, slip or fire protection of hull, tanks, decks and machinery spaces according to the listed coating system.
Common Failures & Inspection Points
  • Blistering caused by moisture, osmotic contamination or poor surface preparation, resulting in raised bubbles and localized coating loss
  • Delamination caused by inadequate surface preparation, contamination or incompatible overcoating, resulting in peeling or loss of adhesion
  • Underfilm corrosion caused by coating damage, holidays or poor edge coverage, resulting in rust staining and progressive coating breakdown
  • Cracking or embrittlement caused by excessive film build, aging or substrate movement, resulting in visible cracks and loss of barrier protection
  • Abrasion, impact or chemical attack caused by service exposure, resulting in worn areas, discoloration or exposed substrate
Service: Inspect coated surfaces for blistering, rusting, cracking, peeling, mechanical damage and edge breakdown. Identify and remove the cause of moisture, contamination or chemical attack before local repair. Prepare the substrate and apply compatible repair coats according to the approved coating specification. Maintain batch, mixing, curing and environmental records where required by the vessel coating plan. Pay particular attention to welds, edges, drains and high-abrasion zones. Refer to the manufacturer documentation for the exact figure for surface preparation, dry-film thickness, curing and overcoating requirements.
Spare Parts: Keep compatible primer, intermediate and topcoat materials required by the vessel coating scheme together with approved thinners, repair materials and application consumables. Coating shelf life and storage conditions must be respected. Do not substitute a different coating chemistry without compatibility and approval checks.
Nippon Paint Marine Coal Tar Epoxy unverified
Type
Coal Tar Epoxy
🎯 Application Area
Application: Used throughout ships and offshore units for corrosion protection, fouling control, deck safety and protection of tanks or exposed structures.
Common Failures & Inspection Points
  • Poor surface preparation can cause early loss of adhesion, seen as peeling, blistering or underfilm corrosion
  • Contamination or moisture during application can create coating defects, noticed as pinholes, craters, soft film or poor cure
  • Mechanical damage can expose the substrate, seen as scratches, impact damage or localized rusting
  • Incompatible overcoating or incorrect application sequence can cause wrinkling or delamination, found during inspection
  • Ageing and environmental attack can reduce film integrity, seen as chalking, erosion, cracking or fouling depending on service
Service: Inspect coating continuity, adhesion-related defects, corrosion breakthrough and damage at welds, edges and high-wear areas. Repairs should use the approved coating scheme and surface-preparation procedure. Film thickness, curing times and environmental application limits not supplied in the source entry must be taken from the coating manufacturer’s documentation.
Spare Parts: Maintain compatible repair coating, approved thinner or cleaner where permitted, and the vessel’s standard surface-preparation and application consumables.
Nippon BT-500 Ballast Tank unverified
Product Line
BT-500
Coating Type
tank
Application Method
airless spray
Dft (µm)
300
Voc (g/l)
160
Overcoating Interval (h)
12
🎯 Application Area
Application: It is used for marine corrosion and surface protection on merchant ships, passenger vessels, offshore units or other vessel types where this equipment category is fitted.
Common Failures & Inspection Points
  • Blistering caused by moisture, osmotic contamination or poor surface preparation, resulting in raised bubbles and localized coating loss
  • Delamination caused by inadequate surface preparation, contamination or incompatible overcoating, resulting in peeling or loss of adhesion
  • Underfilm corrosion caused by coating damage, holidays or poor edge coverage, resulting in rust staining and progressive coating breakdown
  • Cracking or embrittlement caused by excessive film build, aging or substrate movement, resulting in visible cracks and loss of barrier protection
  • Abrasion, impact or chemical attack caused by service exposure, resulting in worn areas, discoloration or exposed substrate
Service: Inspect coated surfaces for blistering, rusting, cracking, peeling, mechanical damage and edge breakdown. Identify and remove the cause of moisture, contamination or chemical attack before local repair. Prepare the substrate and apply compatible repair coats according to the approved coating specification. Maintain batch, mixing, curing and environmental records where required by the vessel coating plan. Pay particular attention to welds, edges, drains and high-abrasion zones. Refer to the manufacturer documentation for the exact figure for surface preparation, dry-film thickness, curing and overcoating requirements.
Spare Parts: Keep compatible primer, intermediate and topcoat materials required by the vessel coating scheme together with approved thinners, repair materials and application consumables. Respect shelf life and storage conditions and do not substitute a different coating chemistry without compatibility checks.
Nippon PSPC System Stripe Coat unverified
Product Line
Nippon PSPC System
Coating Type
tank
Imo pspc compliant
ja
Coat layer
Stripe Coat
Application Method
airless spray
Dft (µm)
160
Voc (g/l)
190
Overcoating Interval (h)
8
🎯 Application Area
Application: Used throughout ships and offshore units for corrosion protection, fouling control, deck safety and protection of tanks or exposed structures.
Common Failures & Inspection Points
  • Poor surface preparation can cause early loss of adhesion, seen as peeling, blistering or underfilm corrosion
  • Contamination or moisture during application can create coating defects, noticed as pinholes, craters, soft film or poor cure
  • Mechanical damage can expose the substrate, seen as scratches, impact damage or localized rusting
  • Incompatible overcoating or incorrect application sequence can cause wrinkling or delamination, found during inspection
  • Ageing and environmental attack can reduce film integrity, seen as chalking, erosion, cracking or fouling depending on service
Service: Inspect coating continuity, adhesion-related defects, corrosion breakthrough and damage at welds, edges and high-wear areas. Repairs should use the approved coating scheme and surface-preparation procedure. Film thickness, curing times and environmental application limits not supplied in the source entry must be taken from the coating manufacturer’s documentation.
Spare Parts: Maintain compatible repair coating, approved thinner or cleaner where permitted, and the vessel’s standard surface-preparation and application consumables.
Nippon PSPC System 1st Full Coat unverified
Product Line
Nippon PSPC System
Coating Type
tank
Imo pspc compliant
ja
Coat layer
1st Full Coat
Application Method
airless spray
Dft (µm)
160
Voc (g/l)
190
Overcoating Interval (h)
8
🎯 Application Area
Application: Used throughout ships and offshore units for corrosion protection, fouling control, deck safety and protection of tanks or exposed structures.
Common Failures & Inspection Points
  • Poor surface preparation can cause early loss of adhesion, seen as peeling, blistering or underfilm corrosion
  • Contamination or moisture during application can create coating defects, noticed as pinholes, craters, soft film or poor cure
  • Mechanical damage can expose the substrate, seen as scratches, impact damage or localized rusting
  • Incompatible overcoating or incorrect application sequence can cause wrinkling or delamination, found during inspection
  • Ageing and environmental attack can reduce film integrity, seen as chalking, erosion, cracking or fouling depending on service
Service: Inspect coating continuity, adhesion-related defects, corrosion breakthrough and damage at welds, edges and high-wear areas. Repairs should use the approved coating scheme and surface-preparation procedure. Film thickness, curing times and environmental application limits not supplied in the source entry must be taken from the coating manufacturer’s documentation.
Spare Parts: Maintain compatible repair coating, approved thinner or cleaner where permitted, and the vessel’s standard surface-preparation and application consumables.
Nippon PSPC System 2nd Full Coat unverified
Product Line
Nippon PSPC System
Coating Type
tank
Imo pspc compliant
ja
Coat layer
2nd Full Coat
Application Method
airless spray
Dft (µm)
160
Voc (g/l)
190
Overcoating Interval (h)
8
🎯 Application Area
Application: Used throughout ships and offshore units for corrosion protection, fouling control, deck safety and protection of tanks or exposed structures.
Common Failures & Inspection Points
  • Poor surface preparation can cause early loss of adhesion, seen as peeling, blistering or underfilm corrosion
  • Contamination or moisture during application can create coating defects, noticed as pinholes, craters, soft film or poor cure
  • Mechanical damage can expose the substrate, seen as scratches, impact damage or localized rusting
  • Incompatible overcoating or incorrect application sequence can cause wrinkling or delamination, found during inspection
  • Ageing and environmental attack can reduce film integrity, seen as chalking, erosion, cracking or fouling depending on service
Service: Inspect coating continuity, adhesion-related defects, corrosion breakthrough and damage at welds, edges and high-wear areas. Repairs should use the approved coating scheme and surface-preparation procedure. Film thickness, curing times and environmental application limits not supplied in the source entry must be taken from the coating manufacturer’s documentation.
Spare Parts: Maintain compatible repair coating, approved thinner or cleaner where permitted, and the vessel’s standard surface-preparation and application consumables.
Nippon PSPC BT IMO PSPC System unverified
Product Line
Nippon PSPC BT
Coating Type
tank
Imo pspc compliant
ja
Application Method
airless spray
Dft (µm)
320
Voc (g/l)
180
🎯 Application Area
Application: Used throughout ships and offshore units for corrosion protection, fouling control, deck safety and protection of tanks or exposed structures.
Common Failures & Inspection Points
  • Poor surface preparation can cause early loss of adhesion, seen as peeling, blistering or underfilm corrosion
  • Contamination or moisture during application can create coating defects, noticed as pinholes, craters, soft film or poor cure
  • Mechanical damage can expose the substrate, seen as scratches, impact damage or localized rusting
  • Incompatible overcoating or incorrect application sequence can cause wrinkling or delamination, found during inspection
  • Ageing and environmental attack can reduce film integrity, seen as chalking, erosion, cracking or fouling depending on service
Service: Inspect coating continuity, adhesion-related defects, corrosion breakthrough and damage at welds, edges and high-wear areas. Repairs should use the approved coating scheme and surface-preparation procedure. Film thickness, curing times and environmental application limits not supplied in the source entry must be taken from the coating manufacturer’s documentation.
Spare Parts: Maintain compatible repair coating, approved thinner or cleaner where permitted, and the vessel’s standard surface-preparation and application consumables.

Nippon Paint Marine Coatings

11
NIPPON CERAMO T/U + NIPPON E-MARINE 2000 and NIPPON CERAMO T/U + NIPPON E-MARINE 2000 LT
Model Number
TAK0000204
🎯 Application Area
Application data not yet recorded.
NIPPON E-MARINE 2000 and NIPPON E-MARINE 2000 LT
Model Number
TAK000020U
🎯 Application Area
Application data not yet recorded.
NIPPON CERAMO T/U + NOA 60 HS-LT FD
Model Number
TAK00002HB
🎯 Application Area
Application data not yet recorded.
NOA 60 HS-LT FD
Model Number
TAK00002HA
🎯 Application Area
Application data not yet recorded.
NOA 60 HS-LTSQ
Model Number
TAK00002DG
🎯 Application Area
Application data not yet recorded.
NIPPON CERAMO T/U + NOA 60 HS-C and NIPPON CERAMO T/U + NOA 60 HS-LTC
Model Number
TAK00001MD
🎯 Application Area
Application data not yet recorded.
NOA 60 HS-C and NOA 60 HS-LTC
Model Number
TAK00001M8
🎯 Application Area
Application data not yet recorded.
UNIPRIME 100 HS-N and UNIPRIME 100 HS-LTQD
Model Number
TAK00001MX
🎯 Application Area
Application data not yet recorded.
NOA 60 HS-N and NOA 60 HS-LTSQ
Model Number
TAK000017D
🎯 Application Area
Application data not yet recorded.
Epicon Zinc Rich Primer B-2 + NOA 60 HS-N and Epicon Zinc Rich Primer B-2 + NOA HS-LTSQ
Model Number
TAK0000122
🎯 Application Area
Application data not yet recorded.
NIPPON CERAMO T/U + NOA 60 HS-N and NIPPON CERAMO T/U + NOA 60 HS-LTSQ
Model Number
TAK000011Y
🎯 Application Area
Application data not yet recorded.

International Paint / AkzoNobel

9
Intershield 300 BT unverified
Type
Ballast Tank Epoxy
Pspc compliant
ja
🎯 Application Area
Application: Used throughout ships and offshore units for corrosion protection, fouling control, deck safety and protection of tanks or exposed structures.
Common Failures & Inspection Points
  • Poor surface preparation can cause early loss of adhesion, seen as peeling, blistering or underfilm corrosion
  • Contamination or moisture during application can create coating defects, noticed as pinholes, craters, soft film or poor cure
  • Mechanical damage can expose the substrate, seen as scratches, impact damage or localized rusting
  • Incompatible overcoating or incorrect application sequence can cause wrinkling or delamination, found during inspection
  • Ageing and environmental attack can reduce film integrity, seen as chalking, erosion, cracking or fouling depending on service
Service: Inspect coating continuity, adhesion-related defects, corrosion breakthrough and damage at welds, edges and high-wear areas. Repairs should use the approved coating scheme and surface-preparation procedure. Film thickness, curing times and environmental application limits not supplied in the source entry must be taken from the coating manufacturer’s documentation.
Spare Parts: Maintain compatible repair coating, approved thinner or cleaner where permitted, and the vessel’s standard surface-preparation and application consumables.
Interswift 6800HS BT unverified
Type
Ballast Tank Coating
🎯 Application Area
Application: Used throughout ships and offshore units for corrosion protection, fouling control, deck safety and protection of tanks or exposed structures.
Common Failures & Inspection Points
  • Poor surface preparation can cause early loss of adhesion, seen as peeling, blistering or underfilm corrosion
  • Contamination or moisture during application can create coating defects, noticed as pinholes, craters, soft film or poor cure
  • Mechanical damage can expose the substrate, seen as scratches, impact damage or localized rusting
  • Incompatible overcoating or incorrect application sequence can cause wrinkling or delamination, found during inspection
  • Ageing and environmental attack can reduce film integrity, seen as chalking, erosion, cracking or fouling depending on service
Service: Inspect coating continuity, adhesion-related defects, corrosion breakthrough and damage at welds, edges and high-wear areas. Repairs should use the approved coating scheme and surface-preparation procedure. Film thickness, curing times and environmental application limits not supplied in the source entry must be taken from the coating manufacturer’s documentation.
Spare Parts: Maintain compatible repair coating, approved thinner or cleaner where permitted, and the vessel’s standard surface-preparation and application consumables.
Inter BT Double Bottom unverified
Position
Double Bottom
Pspc compliant
ja
🎯 Application Area
Application: Used throughout ships and offshore units for corrosion protection, fouling control, deck safety and protection of tanks or exposed structures.
Common Failures & Inspection Points
  • Poor surface preparation can cause early loss of adhesion, seen as peeling, blistering or underfilm corrosion
  • Contamination or moisture during application can create coating defects, noticed as pinholes, craters, soft film or poor cure
  • Mechanical damage can expose the substrate, seen as scratches, impact damage or localized rusting
  • Incompatible overcoating or incorrect application sequence can cause wrinkling or delamination, found during inspection
  • Ageing and environmental attack can reduce film integrity, seen as chalking, erosion, cracking or fouling depending on service
Service: Inspect coating continuity, adhesion-related defects, corrosion breakthrough and damage at welds, edges and high-wear areas. Repairs should use the approved coating scheme and surface-preparation procedure. Film thickness, curing times and environmental application limits not supplied in the source entry must be taken from the coating manufacturer’s documentation.
Spare Parts: Maintain compatible repair coating, approved thinner or cleaner where permitted, and the vessel’s standard surface-preparation and application consumables.
Inter BT Side Tank unverified
Position
Side Tank
Pspc compliant
ja
🎯 Application Area
Application: Used throughout ships and offshore units for corrosion protection, fouling control, deck safety and protection of tanks or exposed structures.
Common Failures & Inspection Points
  • Poor surface preparation can cause early loss of adhesion, seen as peeling, blistering or underfilm corrosion
  • Contamination or moisture during application can create coating defects, noticed as pinholes, craters, soft film or poor cure
  • Mechanical damage can expose the substrate, seen as scratches, impact damage or localized rusting
  • Incompatible overcoating or incorrect application sequence can cause wrinkling or delamination, found during inspection
  • Ageing and environmental attack can reduce film integrity, seen as chalking, erosion, cracking or fouling depending on service
Service: Inspect coating continuity, adhesion-related defects, corrosion breakthrough and damage at welds, edges and high-wear areas. Repairs should use the approved coating scheme and surface-preparation procedure. Film thickness, curing times and environmental application limits not supplied in the source entry must be taken from the coating manufacturer’s documentation.
Spare Parts: Maintain compatible repair coating, approved thinner or cleaner where permitted, and the vessel’s standard surface-preparation and application consumables.
Inter BT Fore Peak unverified
Position
Fore Peak
Pspc compliant
ja
🎯 Application Area
Application: Used throughout ships and offshore units for corrosion protection, fouling control, deck safety and protection of tanks or exposed structures.
Common Failures & Inspection Points
  • Poor surface preparation can cause early loss of adhesion, seen as peeling, blistering or underfilm corrosion
  • Contamination or moisture during application can create coating defects, noticed as pinholes, craters, soft film or poor cure
  • Mechanical damage can expose the substrate, seen as scratches, impact damage or localized rusting
  • Incompatible overcoating or incorrect application sequence can cause wrinkling or delamination, found during inspection
  • Ageing and environmental attack can reduce film integrity, seen as chalking, erosion, cracking or fouling depending on service
Service: Inspect coating continuity, adhesion-related defects, corrosion breakthrough and damage at welds, edges and high-wear areas. Repairs should use the approved coating scheme and surface-preparation procedure. Film thickness, curing times and environmental application limits not supplied in the source entry must be taken from the coating manufacturer’s documentation.
Spare Parts: Maintain compatible repair coating, approved thinner or cleaner where permitted, and the vessel’s standard surface-preparation and application consumables.
Inter BT Aft Peak unverified
Position
Aft Peak
Pspc compliant
ja
🎯 Application Area
Application: Used throughout ships and offshore units for corrosion protection, fouling control, deck safety and protection of tanks or exposed structures.
Common Failures & Inspection Points
  • Poor surface preparation can cause early loss of adhesion, seen as peeling, blistering or underfilm corrosion
  • Contamination or moisture during application can create coating defects, noticed as pinholes, craters, soft film or poor cure
  • Mechanical damage can expose the substrate, seen as scratches, impact damage or localized rusting
  • Incompatible overcoating or incorrect application sequence can cause wrinkling or delamination, found during inspection
  • Ageing and environmental attack can reduce film integrity, seen as chalking, erosion, cracking or fouling depending on service
Service: Inspect coating continuity, adhesion-related defects, corrosion breakthrough and damage at welds, edges and high-wear areas. Repairs should use the approved coating scheme and surface-preparation procedure. Film thickness, curing times and environmental application limits not supplied in the source entry must be taken from the coating manufacturer’s documentation.
Spare Parts: Maintain compatible repair coating, approved thinner or cleaner where permitted, and the vessel’s standard surface-preparation and application consumables.
Inter BT Upper Wing unverified
Position
Upper Wing
Pspc compliant
ja
🎯 Application Area
Application: Used throughout ships and offshore units for corrosion protection, fouling control, deck safety and protection of tanks or exposed structures.
Common Failures & Inspection Points
  • Poor surface preparation can cause early loss of adhesion, seen as peeling, blistering or underfilm corrosion
  • Contamination or moisture during application can create coating defects, noticed as pinholes, craters, soft film or poor cure
  • Mechanical damage can expose the substrate, seen as scratches, impact damage or localized rusting
  • Incompatible overcoating or incorrect application sequence can cause wrinkling or delamination, found during inspection
  • Ageing and environmental attack can reduce film integrity, seen as chalking, erosion, cracking or fouling depending on service
Service: Inspect coating continuity, adhesion-related defects, corrosion breakthrough and damage at welds, edges and high-wear areas. Repairs should use the approved coating scheme and surface-preparation procedure. Film thickness, curing times and environmental application limits not supplied in the source entry must be taken from the coating manufacturer’s documentation.
Spare Parts: Maintain compatible repair coating, approved thinner or cleaner where permitted, and the vessel’s standard surface-preparation and application consumables.
International Paint Coal Tar Epoxy unverified
Type
Coal Tar Epoxy
🎯 Application Area
Application: Used throughout ships and offshore units for corrosion protection, fouling control, deck safety and protection of tanks or exposed structures.
Common Failures & Inspection Points
  • Poor surface preparation can cause early loss of adhesion, seen as peeling, blistering or underfilm corrosion
  • Contamination or moisture during application can create coating defects, noticed as pinholes, craters, soft film or poor cure
  • Mechanical damage can expose the substrate, seen as scratches, impact damage or localized rusting
  • Incompatible overcoating or incorrect application sequence can cause wrinkling or delamination, found during inspection
  • Ageing and environmental attack can reduce film integrity, seen as chalking, erosion, cracking or fouling depending on service
Service: Inspect coating continuity, adhesion-related defects, corrosion breakthrough and damage at welds, edges and high-wear areas. Repairs should use the approved coating scheme and surface-preparation procedure. Film thickness, curing times and environmental application limits not supplied in the source entry must be taken from the coating manufacturer’s documentation.
Spare Parts: Maintain compatible repair coating, approved thinner or cleaner where permitted, and the vessel’s standard surface-preparation and application consumables.
International Paint Potable Water Tank-C unverified
Application
Potable Water Tank
🎯 Application Area
Application: Used throughout ships and offshore units for corrosion protection, fouling control, deck safety and protection of tanks or exposed structures.
Common Failures & Inspection Points
  • Poor surface preparation can cause early loss of adhesion, seen as peeling, blistering or underfilm corrosion
  • Contamination or moisture during application can create coating defects, noticed as pinholes, craters, soft film or poor cure
  • Mechanical damage can expose the substrate, seen as scratches, impact damage or localized rusting
  • Incompatible overcoating or incorrect application sequence can cause wrinkling or delamination, found during inspection
  • Ageing and environmental attack can reduce film integrity, seen as chalking, erosion, cracking or fouling depending on service
Service: Inspect coating continuity, adhesion-related defects, corrosion breakthrough and damage at welds, edges and high-wear areas. Repairs should use the approved coating scheme and surface-preparation procedure. Film thickness, curing times and environmental application limits not supplied in the source entry must be taken from the coating manufacturer’s documentation.
Spare Parts: Maintain compatible repair coating, approved thinner or cleaner where permitted, and the vessel’s standard surface-preparation and application consumables.

PPG

9
SIGMAPRIME® 700 and SIGMAPRIME® 700 LT
Model Number
TAK0000209
🎯 Application Area
Application data not yet recorded.
SIGMAPRIME® 200 and SIGMAPRIME® 200 LT
Model Number
TAK00001XX
🎯 Application Area
Application data not yet recorded.
SIGMAPRIME 700 and SIGMAPRIME 700 LT
Model Number
TAK000026W
🎯 Application Area
Application data not yet recorded.
PPG Coatings Europe B.V. SIGMACOVER™ 280 (1 x 75 µm) and SIGMAGUARD 425 (1 x 250 µm)
SIGMACOVER™ 280 (1 x 75 µm) and SIGMAGUARD 425 (1 x 250 µm)
Model Number
TAK00000ZR
🎯 Application Area
Application data not yet recorded.
SIGMAPRIME® 1000
Model Number
TAK00000V1
🎯 Application Area
Application data not yet recorded.
SIGMACOVER™ 380 and SIGMACOVER™ 380 LT
Model Number
TAK00000J9
🎯 Application Area
Application data not yet recorded.
SIGMAPRIME CSF
Model Number
TAK0000231
🎯 Application Area
Application data not yet recorded.
PPG Coatings Europe B.V. SIGMAPRIME CSF (one coat system)
SIGMAPRIME CSF (one coat system)
Model Number
TAK0000232
🎯 Application Area
Application data not yet recorded.
SIGMAPRIME 700 HSV and SIGMAPRIME 700 HSV LT
Model Number
TAK000022D
🎯 Application Area
Application data not yet recorded.

PPG / Sigma Coatings

8
SigmaShield 880 BT unverified
Type
Ballast Tank Epoxy
Pspc compliant
ja
🎯 Application Area
Application: Corrosion, fouling, chemical, slip or fire protection of hull, tanks, decks and machinery spaces according to the listed coating system.
Common Failures & Inspection Points
  • Blistering caused by moisture, osmotic contamination or poor surface preparation, resulting in raised bubbles and localized coating loss
  • Delamination caused by inadequate surface preparation, contamination or incompatible overcoating, resulting in peeling or loss of adhesion
  • Underfilm corrosion caused by coating damage, holidays or poor edge coverage, resulting in rust staining and progressive coating breakdown
  • Cracking or embrittlement caused by excessive film build, aging or substrate movement, resulting in visible cracks and loss of barrier protection
  • Abrasion, impact or chemical attack caused by service exposure, resulting in worn areas, discoloration or exposed substrate
Service: Inspect coated surfaces for blistering, rusting, cracking, peeling, mechanical damage and edge breakdown. Identify and remove the cause of moisture, contamination or chemical attack before local repair. Prepare the substrate and apply compatible repair coats according to the approved coating specification. Maintain batch, mixing, curing and environmental records where required by the vessel coating plan. Pay particular attention to welds, edges, drains and high-abrasion zones. Refer to the manufacturer documentation for the exact figure for surface preparation, dry-film thickness, curing and overcoating requirements.
Spare Parts: Keep compatible primer, intermediate and topcoat materials required by the vessel coating scheme together with approved thinners, repair materials and application consumables. Coating shelf life and storage conditions must be respected. Do not substitute a different coating chemistry without compatibility and approval checks.
Sigma BT Double Bottom unverified
Position
Double Bottom
Pspc compliant
ja
🎯 Application Area
Application: It is used for marine corrosion and surface protection on merchant ships, passenger vessels, offshore units or other vessel types where this equipment category is fitted.
Common Failures & Inspection Points
  • Blistering caused by moisture, osmotic contamination or poor surface preparation, resulting in raised bubbles and localized coating loss
  • Delamination caused by inadequate surface preparation, contamination or incompatible overcoating, resulting in peeling or loss of adhesion
  • Underfilm corrosion caused by coating damage, holidays or poor edge coverage, resulting in rust staining and progressive coating breakdown
  • Cracking or embrittlement caused by excessive film build, aging or substrate movement, resulting in visible cracks and loss of barrier protection
  • Abrasion, impact or chemical attack caused by service exposure, resulting in worn areas, discoloration or exposed substrate
Service: Inspect coated surfaces for blistering, rusting, cracking, peeling, mechanical damage and edge breakdown. Identify and remove the cause of moisture, contamination or chemical attack before local repair. Prepare the substrate and apply compatible repair coats according to the approved coating specification. Maintain batch, mixing, curing and environmental records where required by the vessel coating plan. Pay particular attention to welds, edges, drains and high-abrasion zones. Refer to the manufacturer documentation for the exact figure for surface preparation, dry-film thickness, curing and overcoating requirements.
Spare Parts: Keep compatible primer, intermediate and topcoat materials required by the vessel coating scheme together with approved thinners, repair materials and application consumables. Respect shelf life and storage conditions and do not substitute a different coating chemistry without compatibility checks.
Sigma BT Side Tank unverified
Position
Side Tank
Pspc compliant
ja
🎯 Application Area
Application: Corrosion, fouling, chemical, slip or fire protection of hull, tanks, decks and machinery spaces according to the listed coating system.
Common Failures & Inspection Points
  • Blistering caused by moisture, osmotic contamination or poor surface preparation, resulting in raised bubbles and localized coating loss
  • Delamination caused by inadequate surface preparation, contamination or incompatible overcoating, resulting in peeling or loss of adhesion
  • Underfilm corrosion caused by coating damage, holidays or poor edge coverage, resulting in rust staining and progressive coating breakdown
  • Cracking or embrittlement caused by excessive film build, aging or substrate movement, resulting in visible cracks and loss of barrier protection
  • Abrasion, impact or chemical attack caused by service exposure, resulting in worn areas, discoloration or exposed substrate
Service: Inspect coated surfaces for blistering, rusting, cracking, peeling, mechanical damage and edge breakdown. Identify and remove the cause of moisture, contamination or chemical attack before local repair. Prepare the substrate and apply compatible repair coats according to the approved coating specification. Maintain batch, mixing, curing and environmental records where required by the vessel coating plan. Pay particular attention to welds, edges, drains and high-abrasion zones. Refer to the manufacturer documentation for the exact figure for surface preparation, dry-film thickness, curing and overcoating requirements.
Spare Parts: Keep compatible primer, intermediate and topcoat materials required by the vessel coating scheme together with approved thinners, repair materials and application consumables. Coating shelf life and storage conditions must be respected. Do not substitute a different coating chemistry without compatibility and approval checks.
Sigma BT Fore Peak unverified
Position
Fore Peak
Pspc compliant
ja
🎯 Application Area
Application: Corrosion, fouling, chemical, slip or fire protection of hull, tanks, decks and machinery spaces according to the listed coating system.
Common Failures & Inspection Points
  • Blistering caused by moisture, osmotic contamination or poor surface preparation, resulting in raised bubbles and localized coating loss
  • Delamination caused by inadequate surface preparation, contamination or incompatible overcoating, resulting in peeling or loss of adhesion
  • Underfilm corrosion caused by coating damage, holidays or poor edge coverage, resulting in rust staining and progressive coating breakdown
  • Cracking or embrittlement caused by excessive film build, aging or substrate movement, resulting in visible cracks and loss of barrier protection
  • Abrasion, impact or chemical attack caused by service exposure, resulting in worn areas, discoloration or exposed substrate
Service: Inspect coated surfaces for blistering, rusting, cracking, peeling, mechanical damage and edge breakdown. Identify and remove the cause of moisture, contamination or chemical attack before local repair. Prepare the substrate and apply compatible repair coats according to the approved coating specification. Maintain batch, mixing, curing and environmental records where required by the vessel coating plan. Pay particular attention to welds, edges, drains and high-abrasion zones. Refer to the manufacturer documentation for the exact figure for surface preparation, dry-film thickness, curing and overcoating requirements.
Spare Parts: Keep compatible primer, intermediate and topcoat materials required by the vessel coating scheme together with approved thinners, repair materials and application consumables. Coating shelf life and storage conditions must be respected. Do not substitute a different coating chemistry without compatibility and approval checks.
Sigma BT Aft Peak unverified
Position
Aft Peak
Pspc compliant
ja
🎯 Application Area
Application: Corrosion, fouling, chemical, slip or fire protection of hull, tanks, decks and machinery spaces according to the listed coating system.
Common Failures & Inspection Points
  • Blistering caused by moisture, osmotic contamination or poor surface preparation, resulting in raised bubbles and localized coating loss
  • Delamination caused by inadequate surface preparation, contamination or incompatible overcoating, resulting in peeling or loss of adhesion
  • Underfilm corrosion caused by coating damage, holidays or poor edge coverage, resulting in rust staining and progressive coating breakdown
  • Cracking or embrittlement caused by excessive film build, aging or substrate movement, resulting in visible cracks and loss of barrier protection
  • Abrasion, impact or chemical attack caused by service exposure, resulting in worn areas, discoloration or exposed substrate
Service: Inspect coated surfaces for blistering, rusting, cracking, peeling, mechanical damage and edge breakdown. Identify and remove the cause of moisture, contamination or chemical attack before local repair. Prepare the substrate and apply compatible repair coats according to the approved coating specification. Maintain batch, mixing, curing and environmental records where required by the vessel coating plan. Pay particular attention to welds, edges, drains and high-abrasion zones. Refer to the manufacturer documentation for the exact figure for surface preparation, dry-film thickness, curing and overcoating requirements.
Spare Parts: Keep compatible primer, intermediate and topcoat materials required by the vessel coating scheme together with approved thinners, repair materials and application consumables. Coating shelf life and storage conditions must be respected. Do not substitute a different coating chemistry without compatibility and approval checks.
Sigma BT Upper Wing unverified
Position
Upper Wing
Pspc compliant
ja
🎯 Application Area
Application: Corrosion, fouling, chemical, slip or fire protection of hull, tanks, decks and machinery spaces according to the listed coating system.
Common Failures & Inspection Points
  • Blistering caused by moisture, osmotic contamination or poor surface preparation, resulting in raised bubbles and localized coating loss
  • Delamination caused by inadequate surface preparation, contamination or incompatible overcoating, resulting in peeling or loss of adhesion
  • Underfilm corrosion caused by coating damage, holidays or poor edge coverage, resulting in rust staining and progressive coating breakdown
  • Cracking or embrittlement caused by excessive film build, aging or substrate movement, resulting in visible cracks and loss of barrier protection
  • Abrasion, impact or chemical attack caused by service exposure, resulting in worn areas, discoloration or exposed substrate
Service: Inspect coated surfaces for blistering, rusting, cracking, peeling, mechanical damage and edge breakdown. Identify and remove the cause of moisture, contamination or chemical attack before local repair. Prepare the substrate and apply compatible repair coats according to the approved coating specification. Maintain batch, mixing, curing and environmental records where required by the vessel coating plan. Pay particular attention to welds, edges, drains and high-abrasion zones. Refer to the manufacturer documentation for the exact figure for surface preparation, dry-film thickness, curing and overcoating requirements.
Spare Parts: Keep compatible primer, intermediate and topcoat materials required by the vessel coating scheme together with approved thinners, repair materials and application consumables. Coating shelf life and storage conditions must be respected. Do not substitute a different coating chemistry without compatibility and approval checks.
PPG Coal Tar Epoxy unverified
Type
Coal Tar Epoxy
🎯 Application Area
Application: Corrosion, fouling, chemical, slip or fire protection of hull, tanks, decks and machinery spaces according to the listed coating system.
Common Failures & Inspection Points
  • Blistering caused by moisture, osmotic contamination or poor surface preparation, resulting in raised bubbles and localized coating loss
  • Delamination caused by inadequate surface preparation, contamination or incompatible overcoating, resulting in peeling or loss of adhesion
  • Underfilm corrosion caused by coating damage, holidays or poor edge coverage, resulting in rust staining and progressive coating breakdown
  • Cracking or embrittlement caused by excessive film build, aging or substrate movement, resulting in visible cracks and loss of barrier protection
  • Abrasion, impact or chemical attack caused by service exposure, resulting in worn areas, discoloration or exposed substrate
Service: Inspect coated surfaces for blistering, rusting, cracking, peeling, mechanical damage and edge breakdown. Identify and remove the cause of moisture, contamination or chemical attack before local repair. Prepare the substrate and apply compatible repair coats according to the approved coating specification. Maintain batch, mixing, curing and environmental records where required by the vessel coating plan. Pay particular attention to welds, edges, drains and high-abrasion zones. Refer to the manufacturer documentation for the exact figure for surface preparation, dry-film thickness, curing and overcoating requirements.
Spare Parts: Keep compatible primer, intermediate and topcoat materials required by the vessel coating scheme together with approved thinners, repair materials and application consumables. Coating shelf life and storage conditions must be respected. Do not substitute a different coating chemistry without compatibility and approval checks.
PPG Potable Water Tank-C unverified
Application
Potable Water Tank
🎯 Application Area
Application: Used throughout ships and offshore units for corrosion protection, fouling control, deck safety and protection of tanks or exposed structures.
Common Failures & Inspection Points
  • Poor surface preparation can cause early loss of adhesion, seen as peeling, blistering or underfilm corrosion
  • Contamination or moisture during application can create coating defects, noticed as pinholes, craters, soft film or poor cure
  • Mechanical damage can expose the substrate, seen as scratches, impact damage or localized rusting
  • Incompatible overcoating or incorrect application sequence can cause wrinkling or delamination, found during inspection
  • Ageing and environmental attack can reduce film integrity, seen as chalking, erosion, cracking or fouling depending on service
Service: Inspect coating continuity, adhesion-related defects, corrosion breakthrough and damage at welds, edges and high-wear areas. Repairs should use the approved coating scheme and surface-preparation procedure. Film thickness, curing times and environmental application limits not supplied in the source entry must be taken from the coating manufacturer’s documentation.
Spare Parts: Maintain compatible repair coating, approved thinner or cleaner where permitted, and the vessel’s standard surface-preparation and application consumables.

Carboline

6
Carboguard 1340 BT unverified
Product Line
Carboguard
Coating Type
tank
Application Method
airless spray
Dft (µm)
350
Voc (g/l)
145
Overcoating Interval (h)
12
🎯 Application Area
Application: Used on hulls, ballast tanks, cargo tanks, decks, superstructures, machinery spaces, and fire-protected areas on all vessel types.
Common Failures & Inspection Points
  • Poor surface preparation leaves rust, salts, oil, or dust beneath the coating and causes early blistering, delamination, or underfilm corrosion
  • Mechanical damage from impact, abrasion, cargo, or maintenance exposes the substrate and produces localized corrosion
  • Incorrect application conditions or film build cause pinholes, runs, cracking, incomplete cure, or weak adhesion
  • Chemical, UV, immersion, or temperature exposure beyond the coating capability causes softening, chalking, discoloration, or erosion
  • Ageing and repeated maintenance create incompatible layers or weak interfaces that peel during inspection or cleaning
Service: Inspect coating continuity, adhesion condition, rusting, blistering, cracking, mechanical damage, weld and edge coverage, and areas exposed to standing water or cargo. Surface preparation, environmental limits, dry-film thickness, curing, and compatibility must follow the approved coating specification and manufacturer documentation.
Spare Parts: Keep compatible primer, topcoat or repair material from the approved coating system, together with manufacturer-specified thinners, fillers, and repair consumables; do not substitute unapproved products.
Carboguard 891 BT unverified
Product Line
Carboguard
Coating Type
tank
Application Method
airless spray
Dft (µm)
300
Voc (g/l)
155
Overcoating Interval (h)
12
🎯 Application Area
Application: Hull, ballast tank, cargo tank, deck, superstructure, pipework and fire-protection coating systems.
Common Failures & Inspection Points
  • Poor surface preparation causes loss of adhesion, blistering or early coating breakdown
  • Incorrect film build or application conditions cause runs, pinholes, incomplete cure or premature wear
  • Mechanical damage exposes the substrate and leads to localized corrosion
  • Chemical, cargo or immersion incompatibility causes softening, swelling, discoloration or delamination
  • Incorrect mixing, induction or overcoating practice causes poor cure or intercoat adhesion
Service: Inspect coating continuity, adhesion, cracking, blistering, rusting and mechanical damage. Review surface preparation and application records where available and identify whether failures are local or systemic. Repair only with compatible products and approved preparation. Refer to the coating manufacturer's documentation for the exact figure for film thickness, mixing ratio, cure time and environmental limits.
Spare Parts: Keep compatible touch-up coating, approved thinner or cleaner, repair primers and application consumables in accordance with the vessel coating maintenance plan.
Carboguard PSPC Stripe Coat unverified
Product Line
Carboguard PSPC
Coating Type
tank
Imo pspc compliant
ja
Coat layer
Stripe Coat
Application Method
airless spray
Dft (µm)
160
Voc (g/l)
190
Overcoating Interval (h)
8
🎯 Application Area
Application: Corrosion, fouling, chemical, slip or fire protection of hull, tanks, decks and machinery spaces according to the listed coating system.
Common Failures & Inspection Points
  • Blistering caused by moisture, osmotic contamination or poor surface preparation, resulting in raised bubbles and localized coating loss
  • Delamination caused by inadequate surface preparation, contamination or incompatible overcoating, resulting in peeling or loss of adhesion
  • Underfilm corrosion caused by coating damage, holidays or poor edge coverage, resulting in rust staining and progressive coating breakdown
  • Cracking or embrittlement caused by excessive film build, aging or substrate movement, resulting in visible cracks and loss of barrier protection
  • Abrasion, impact or chemical attack caused by service exposure, resulting in worn areas, discoloration or exposed substrate
Service: Inspect coated surfaces for blistering, rusting, cracking, peeling, mechanical damage and edge breakdown. Identify and remove the cause of moisture, contamination or chemical attack before local repair. Prepare the substrate and apply compatible repair coats according to the approved coating specification. Maintain batch, mixing, curing and environmental records where required by the vessel coating plan. Pay particular attention to welds, edges, drains and high-abrasion zones. Refer to the manufacturer documentation for the exact figure for surface preparation, dry-film thickness, curing and overcoating requirements.
Spare Parts: Keep compatible primer, intermediate and topcoat materials required by the vessel coating scheme together with approved thinners, repair materials and application consumables. Coating shelf life and storage conditions must be respected. Do not substitute a different coating chemistry without compatibility and approval checks.
Carboguard PSPC 1st Full Coat unverified
Product Line
Carboguard PSPC
Coating Type
tank
Imo pspc compliant
ja
Coat layer
1st Full Coat
Application Method
airless spray
Dft (µm)
160
Voc (g/l)
190
Overcoating Interval (h)
8
🎯 Application Area
Application: Corrosion, fouling, chemical, slip or fire protection of hull, tanks, decks and machinery spaces according to the listed coating system.
Common Failures & Inspection Points
  • Blistering caused by moisture, osmotic contamination or poor surface preparation, resulting in raised bubbles and localized coating loss
  • Delamination caused by inadequate surface preparation, contamination or incompatible overcoating, resulting in peeling or loss of adhesion
  • Underfilm corrosion caused by coating damage, holidays or poor edge coverage, resulting in rust staining and progressive coating breakdown
  • Cracking or embrittlement caused by excessive film build, aging or substrate movement, resulting in visible cracks and loss of barrier protection
  • Abrasion, impact or chemical attack caused by service exposure, resulting in worn areas, discoloration or exposed substrate
Service: Inspect coated surfaces for blistering, rusting, cracking, peeling, mechanical damage and edge breakdown. Identify and remove the cause of moisture, contamination or chemical attack before local repair. Prepare the substrate and apply compatible repair coats according to the approved coating specification. Maintain batch, mixing, curing and environmental records where required by the vessel coating plan. Pay particular attention to welds, edges, drains and high-abrasion zones. Refer to the manufacturer documentation for the exact figure for surface preparation, dry-film thickness, curing and overcoating requirements.
Spare Parts: Keep compatible primer, intermediate and topcoat materials required by the vessel coating scheme together with approved thinners, repair materials and application consumables. Coating shelf life and storage conditions must be respected. Do not substitute a different coating chemistry without compatibility and approval checks.
Carboguard PSPC 2nd Full Coat unverified
Product Line
Carboguard PSPC
Coating Type
tank
Imo pspc compliant
ja
Coat layer
2nd Full Coat
Application Method
airless spray
Dft (µm)
160
Voc (g/l)
190
Overcoating Interval (h)
8
🎯 Application Area
Application: Corrosion, fouling, chemical, slip or fire protection of hull, tanks, decks and machinery spaces according to the listed coating system.
Common Failures & Inspection Points
  • Blistering caused by moisture, osmotic contamination or poor surface preparation, resulting in raised bubbles and localized coating loss
  • Delamination caused by inadequate surface preparation, contamination or incompatible overcoating, resulting in peeling or loss of adhesion
  • Underfilm corrosion caused by coating damage, holidays or poor edge coverage, resulting in rust staining and progressive coating breakdown
  • Cracking or embrittlement caused by excessive film build, aging or substrate movement, resulting in visible cracks and loss of barrier protection
  • Abrasion, impact or chemical attack caused by service exposure, resulting in worn areas, discoloration or exposed substrate
Service: Inspect coated surfaces for blistering, rusting, cracking, peeling, mechanical damage and edge breakdown. Identify and remove the cause of moisture, contamination or chemical attack before local repair. Prepare the substrate and apply compatible repair coats according to the approved coating specification. Maintain batch, mixing, curing and environmental records where required by the vessel coating plan. Pay particular attention to welds, edges, drains and high-abrasion zones. Refer to the manufacturer documentation for the exact figure for surface preparation, dry-film thickness, curing and overcoating requirements.
Spare Parts: Keep compatible primer, intermediate and topcoat materials required by the vessel coating scheme together with approved thinners, repair materials and application consumables. Coating shelf life and storage conditions must be respected. Do not substitute a different coating chemistry without compatibility and approval checks.
Carboguard PSPC 891 IMO PSPC System unverified
Product Line
Carboguard PSPC 891
Coating Type
tank
Imo pspc compliant
ja
Application Method
airless spray
Dft (µm)
320
Voc (g/l)
180
🎯 Application Area
Application: It is used for marine corrosion and surface protection on merchant ships, passenger vessels, offshore units or other vessel types where this equipment category is fitted.
Common Failures & Inspection Points
  • Blistering caused by moisture, osmotic contamination or poor surface preparation, resulting in raised bubbles and localized coating loss
  • Delamination caused by inadequate surface preparation, contamination or incompatible overcoating, resulting in peeling or loss of adhesion
  • Underfilm corrosion caused by coating damage, holidays or poor edge coverage, resulting in rust staining and progressive coating breakdown
  • Cracking or embrittlement caused by excessive film build, aging or substrate movement, resulting in visible cracks and loss of barrier protection
  • Abrasion, impact or chemical attack caused by service exposure, resulting in worn areas, discoloration or exposed substrate
Service: Inspect coated surfaces for blistering, rusting, cracking, peeling, mechanical damage and edge breakdown. Identify and remove the cause of moisture, contamination or chemical attack before local repair. Prepare the substrate and apply compatible repair coats according to the approved coating specification. Maintain batch, mixing, curing and environmental records where required by the vessel coating plan. Pay particular attention to welds, edges, drains and high-abrasion zones. Refer to the manufacturer documentation for the exact figure for surface preparation, dry-film thickness, curing and overcoating requirements.
Spare Parts: Keep compatible primer, intermediate and topcoat materials required by the vessel coating scheme together with approved thinners, repair materials and application consumables. Respect shelf life and storage conditions and do not substitute a different coating chemistry without compatibility checks.

Chugoku Samhwa Paints

6
BANNOH 2000 HS AL and BANNOH 2000 HS AL QD
Model Number
TAK00002K1
🎯 Application Area
Application data not yet recorded.
BANNOH 2000 HS QD + BANNOH 1500 QD
Model Number
TAK00002K0
🎯 Application Area
Application data not yet recorded.
BANNOH 2000 HS [M2-42155A], BANNOH 2000 HS [M2-42156A] and BANNOH 2000 HS QD [M2-42160A]
Model Number
TAK00002B2
🎯 Application Area
Application data not yet recorded.
BANNOH 5000 x BANNOH 1500 QD and BANNOH 5000 QD x BANNOH 1500 QD
Model Number
TAK0000234
🎯 Application Area
Application data not yet recorded.
BANNOH 5000 x BANNOH 500 QD and BANNOH 5000 QD x BANNOH 5000
Model Number
TAK0000235
🎯 Application Area
Application data not yet recorded.
BANNOH 2000 and BANNOH 2000 QD
Model Number
TAK00000G3
🎯 Application Area
Application data not yet recorded.

International / AkzoNobel

6
Interzone 1000 unverified
Product Line
Interzone
Coating Type
tank
Application Method
airless spray
Dft (µm)
350
Voc (g/l)
140
Overcoating Interval (h)
24
🎯 Application Area
Application: Corrosion, fouling, chemical, slip or fire protection of hull, tanks, decks and machinery spaces according to the listed coating system.
Common Failures & Inspection Points
  • Blistering caused by moisture, osmotic contamination or poor surface preparation, resulting in raised bubbles and localized coating loss
  • Delamination caused by inadequate surface preparation, contamination or incompatible overcoating, resulting in peeling or loss of adhesion
  • Underfilm corrosion caused by coating damage, holidays or poor edge coverage, resulting in rust staining and progressive coating breakdown
  • Cracking or embrittlement caused by excessive film build, aging or substrate movement, resulting in visible cracks and loss of barrier protection
  • Abrasion, impact or chemical attack caused by service exposure, resulting in worn areas, discoloration or exposed substrate
Service: Inspect coated surfaces for blistering, rusting, cracking, peeling, mechanical damage and edge breakdown. Identify and remove the cause of moisture, contamination or chemical attack before local repair. Prepare the substrate and apply compatible repair coats according to the approved coating specification. Maintain batch, mixing, curing and environmental records where required by the vessel coating plan. Pay particular attention to welds, edges, drains and high-abrasion zones. Refer to the manufacturer documentation for the exact figure for surface preparation, dry-film thickness, curing and overcoating requirements.
Spare Parts: Keep compatible primer, intermediate and topcoat materials required by the vessel coating scheme together with approved thinners, repair materials and application consumables. Coating shelf life and storage conditions must be respected. Do not substitute a different coating chemistry without compatibility and approval checks.
Interzone 954 unverified
Product Line
Interzone
Coating Type
tank
Application Method
airless spray
Dft (µm)
300
Voc (g/l)
155
Overcoating Interval (h)
18
🎯 Application Area
Application: Corrosion, fouling, chemical, slip or fire protection of hull, tanks, decks and machinery spaces according to the listed coating system.
Common Failures & Inspection Points
  • Blistering caused by moisture, osmotic contamination or poor surface preparation, resulting in raised bubbles and localized coating loss
  • Delamination caused by inadequate surface preparation, contamination or incompatible overcoating, resulting in peeling or loss of adhesion
  • Underfilm corrosion caused by coating damage, holidays or poor edge coverage, resulting in rust staining and progressive coating breakdown
  • Cracking or embrittlement caused by excessive film build, aging or substrate movement, resulting in visible cracks and loss of barrier protection
  • Abrasion, impact or chemical attack caused by service exposure, resulting in worn areas, discoloration or exposed substrate
Service: Inspect coated surfaces for blistering, rusting, cracking, peeling, mechanical damage and edge breakdown. Identify and remove the cause of moisture, contamination or chemical attack before local repair. Prepare the substrate and apply compatible repair coats according to the approved coating specification. Maintain batch, mixing, curing and environmental records where required by the vessel coating plan. Pay particular attention to welds, edges, drains and high-abrasion zones. Refer to the manufacturer documentation for the exact figure for surface preparation, dry-film thickness, curing and overcoating requirements.
Spare Parts: Keep compatible primer, intermediate and topcoat materials required by the vessel coating scheme together with approved thinners, repair materials and application consumables. Coating shelf life and storage conditions must be respected. Do not substitute a different coating chemistry without compatibility and approval checks.
Interzone PSPC Stripe Coat unverified
Product Line
Interzone PSPC
Coating Type
tank
Imo pspc compliant
ja
Coat layer
Stripe Coat
Application Method
airless spray
Dft (µm)
160
Voc (g/l)
190
Overcoating Interval (h)
8
🎯 Application Area
Application: Used throughout ships and offshore units for corrosion protection, fouling control, deck safety and protection of tanks or exposed structures.
Common Failures & Inspection Points
  • Poor surface preparation can cause early loss of adhesion, seen as peeling, blistering or underfilm corrosion
  • Contamination or moisture during application can create coating defects, noticed as pinholes, craters, soft film or poor cure
  • Mechanical damage can expose the substrate, seen as scratches, impact damage or localized rusting
  • Incompatible overcoating or incorrect application sequence can cause wrinkling or delamination, found during inspection
  • Ageing and environmental attack can reduce film integrity, seen as chalking, erosion, cracking or fouling depending on service
Service: Inspect coating continuity, adhesion-related defects, corrosion breakthrough and damage at welds, edges and high-wear areas. Repairs should use the approved coating scheme and surface-preparation procedure. Film thickness, curing times and environmental application limits not supplied in the source entry must be taken from the coating manufacturer’s documentation.
Spare Parts: Maintain compatible repair coating, approved thinner or cleaner where permitted, and the vessel’s standard surface-preparation and application consumables.
Interzone PSPC 1st Full Coat unverified
Product Line
Interzone PSPC
Coating Type
tank
Imo pspc compliant
ja
Coat layer
1st Full Coat
Application Method
airless spray
Dft (µm)
160
Voc (g/l)
190
Overcoating Interval (h)
8
🎯 Application Area
Application: Used throughout ships and offshore units for corrosion protection, fouling control, deck safety and protection of tanks or exposed structures.
Common Failures & Inspection Points
  • Poor surface preparation can cause early loss of adhesion, seen as peeling, blistering or underfilm corrosion
  • Contamination or moisture during application can create coating defects, noticed as pinholes, craters, soft film or poor cure
  • Mechanical damage can expose the substrate, seen as scratches, impact damage or localized rusting
  • Incompatible overcoating or incorrect application sequence can cause wrinkling or delamination, found during inspection
  • Ageing and environmental attack can reduce film integrity, seen as chalking, erosion, cracking or fouling depending on service
Service: Inspect coating continuity, adhesion-related defects, corrosion breakthrough and damage at welds, edges and high-wear areas. Repairs should use the approved coating scheme and surface-preparation procedure. Film thickness, curing times and environmental application limits not supplied in the source entry must be taken from the coating manufacturer’s documentation.
Spare Parts: Maintain compatible repair coating, approved thinner or cleaner where permitted, and the vessel’s standard surface-preparation and application consumables.
Interzone PSPC 2nd Full Coat unverified
Product Line
Interzone PSPC
Coating Type
tank
Imo pspc compliant
ja
Coat layer
2nd Full Coat
Application Method
airless spray
Dft (µm)
160
Voc (g/l)
190
Overcoating Interval (h)
8
🎯 Application Area
Application: Used throughout ships and offshore units for corrosion protection, fouling control, deck safety and protection of tanks or exposed structures.
Common Failures & Inspection Points
  • Poor surface preparation can cause early loss of adhesion, seen as peeling, blistering or underfilm corrosion
  • Contamination or moisture during application can create coating defects, noticed as pinholes, craters, soft film or poor cure
  • Mechanical damage can expose the substrate, seen as scratches, impact damage or localized rusting
  • Incompatible overcoating or incorrect application sequence can cause wrinkling or delamination, found during inspection
  • Ageing and environmental attack can reduce film integrity, seen as chalking, erosion, cracking or fouling depending on service
Service: Inspect coating continuity, adhesion-related defects, corrosion breakthrough and damage at welds, edges and high-wear areas. Repairs should use the approved coating scheme and surface-preparation procedure. Film thickness, curing times and environmental application limits not supplied in the source entry must be taken from the coating manufacturer’s documentation.
Spare Parts: Maintain compatible repair coating, approved thinner or cleaner where permitted, and the vessel’s standard surface-preparation and application consumables.
Interzone PSPC 1000 IMO PSPC System unverified
Product Line
Interzone PSPC 1000
Coating Type
tank
Imo pspc compliant
ja
Application Method
airless spray
Dft (µm)
320
Voc (g/l)
180
🎯 Application Area
Application: Used throughout ships and offshore units for corrosion protection, fouling control, deck safety and protection of tanks or exposed structures.
Common Failures & Inspection Points
  • Poor surface preparation can cause early loss of adhesion, seen as peeling, blistering or underfilm corrosion
  • Contamination or moisture during application can create coating defects, noticed as pinholes, craters, soft film or poor cure
  • Mechanical damage can expose the substrate, seen as scratches, impact damage or localized rusting
  • Incompatible overcoating or incorrect application sequence can cause wrinkling or delamination, found during inspection
  • Ageing and environmental attack can reduce film integrity, seen as chalking, erosion, cracking or fouling depending on service
Service: Inspect coating continuity, adhesion-related defects, corrosion breakthrough and damage at welds, edges and high-wear areas. Repairs should use the approved coating scheme and surface-preparation procedure. Film thickness, curing times and environmental application limits not supplied in the source entry must be taken from the coating manufacturer’s documentation.
Spare Parts: Maintain compatible repair coating, approved thinner or cleaner where permitted, and the vessel’s standard surface-preparation and application consumables.

Shanghai Hilong Shine New Materials

6
HilonUprimer 3500
Model Number
TAK000004D
🎯 Application Area
Application data not yet recorded.
HilonUprimer 3200
Model Number
TAK000004B
🎯 Application Area
Application data not yet recorded.
HilonUprimer 3300
Model Number
TAK000004C
🎯 Application Area
Application data not yet recorded.
HilonUprimer 3105
Model Number
TAK0000049
🎯 Application Area
Application data not yet recorded.
HilonUprimer 3100
Model Number
TAK0000048
🎯 Application Area
Application data not yet recorded.
HilonUprimer 3120
Model Number
TAK000004A
🎯 Application Area
Application data not yet recorded.

PPG / Sigma

5
SigmaShield 1200 BT unverified
Product Line
SigmaShield
Coating Type
tank
Application Method
airless spray
Dft (µm)
300
Voc (g/l)
150
Overcoating Interval (h)
12
🎯 Application Area
Application: Used on hulls, decks, ballast/cargo tanks, machinery spaces and exposed structures according to coating type and service environment. This entry applies specifically to the Ballast Tank Coating variant identified as PPG / Sigma SigmaShield 1200 BT.
Common Failures & Inspection Points
  • Adhesion loss from inadequate surface preparation or contamination, typically indicated by flaking, peeling or blistering
  • Osmotic blistering or moisture entrapment, typically indicated by blisters and localized coating breakdown
  • Mechanical damage or abrasion, typically indicated by exposed substrate, scratches or coating loss
  • Incorrect mixing/application conditions, typically indicated by poor curing, soft film or uneven finish
  • Chemical or UV degradation beyond the coating's service suitability, typically indicated by chalking, discoloration or premature breakdown
Service: Inspect coating continuity, rusting, blistering, cracking and mechanical damage; prepare surfaces and apply repair coats strictly to the approved coating specification and manufacturer data, including exact film thickness and curing requirements.
Spare Parts: Maintain compatible primer, intermediate/topcoat materials, thinners and repair consumables within shelf-life and storage requirements; use only products approved for the existing coating scheme.
SigmaShield PSPC Stripe Coat unverified
Product Line
SigmaShield PSPC
Coating Type
tank
Imo pspc compliant
ja
Coat layer
Stripe Coat
Application Method
airless spray
Dft (µm)
160
Voc (g/l)
190
Overcoating Interval (h)
8
🎯 Application Area
Application: Corrosion, fouling, chemical, slip or fire protection of hull, tanks, decks and machinery spaces according to the listed coating system.
Common Failures & Inspection Points
  • Blistering caused by moisture, osmotic contamination or poor surface preparation, resulting in raised bubbles and localized coating loss
  • Delamination caused by inadequate surface preparation, contamination or incompatible overcoating, resulting in peeling or loss of adhesion
  • Underfilm corrosion caused by coating damage, holidays or poor edge coverage, resulting in rust staining and progressive coating breakdown
  • Cracking or embrittlement caused by excessive film build, aging or substrate movement, resulting in visible cracks and loss of barrier protection
  • Abrasion, impact or chemical attack caused by service exposure, resulting in worn areas, discoloration or exposed substrate
Service: Inspect coated surfaces for blistering, rusting, cracking, peeling, mechanical damage and edge breakdown. Identify and remove the cause of moisture, contamination or chemical attack before local repair. Prepare the substrate and apply compatible repair coats according to the approved coating specification. Maintain batch, mixing, curing and environmental records where required by the vessel coating plan. Pay particular attention to welds, edges, drains and high-abrasion zones. Refer to the manufacturer documentation for the exact figure for surface preparation, dry-film thickness, curing and overcoating requirements.
Spare Parts: Keep compatible primer, intermediate and topcoat materials required by the vessel coating scheme together with approved thinners, repair materials and application consumables. Coating shelf life and storage conditions must be respected. Do not substitute a different coating chemistry without compatibility and approval checks.
SigmaShield PSPC 1st Full Coat unverified
Product Line
SigmaShield PSPC
Coating Type
tank
Imo pspc compliant
ja
Coat layer
1st Full Coat
Application Method
airless spray
Dft (µm)
160
Voc (g/l)
190
Overcoating Interval (h)
8
🎯 Application Area
Application: It is used for marine corrosion and surface protection on merchant ships, passenger vessels, offshore units or other vessel types where this equipment category is fitted.
Common Failures & Inspection Points
  • Blistering caused by moisture, osmotic contamination or poor surface preparation, resulting in raised bubbles and localized coating loss
  • Delamination caused by inadequate surface preparation, contamination or incompatible overcoating, resulting in peeling or loss of adhesion
  • Underfilm corrosion caused by coating damage, holidays or poor edge coverage, resulting in rust staining and progressive coating breakdown
  • Cracking or embrittlement caused by excessive film build, aging or substrate movement, resulting in visible cracks and loss of barrier protection
  • Abrasion, impact or chemical attack caused by service exposure, resulting in worn areas, discoloration or exposed substrate
Service: Inspect coated surfaces for blistering, rusting, cracking, peeling, mechanical damage and edge breakdown. Identify and remove the cause of moisture, contamination or chemical attack before local repair. Prepare the substrate and apply compatible repair coats according to the approved coating specification. Maintain batch, mixing, curing and environmental records where required by the vessel coating plan. Pay particular attention to welds, edges, drains and high-abrasion zones. Refer to the manufacturer documentation for the exact figure for surface preparation, dry-film thickness, curing and overcoating requirements.
Spare Parts: Keep compatible primer, intermediate and topcoat materials required by the vessel coating scheme together with approved thinners, repair materials and application consumables. Respect shelf life and storage conditions and do not substitute a different coating chemistry without compatibility checks.
SigmaShield PSPC 2nd Full Coat unverified
Product Line
SigmaShield PSPC
Coating Type
tank
Imo pspc compliant
ja
Coat layer
2nd Full Coat
Application Method
airless spray
Dft (µm)
160
Voc (g/l)
190
Overcoating Interval (h)
8
🎯 Application Area
Application: It is used for marine corrosion and surface protection on merchant ships, passenger vessels, offshore units or other vessel types where this equipment category is fitted.
Common Failures & Inspection Points
  • Blistering caused by moisture, osmotic contamination or poor surface preparation, resulting in raised bubbles and localized coating loss
  • Delamination caused by inadequate surface preparation, contamination or incompatible overcoating, resulting in peeling or loss of adhesion
  • Underfilm corrosion caused by coating damage, holidays or poor edge coverage, resulting in rust staining and progressive coating breakdown
  • Cracking or embrittlement caused by excessive film build, aging or substrate movement, resulting in visible cracks and loss of barrier protection
  • Abrasion, impact or chemical attack caused by service exposure, resulting in worn areas, discoloration or exposed substrate
Service: Inspect coated surfaces for blistering, rusting, cracking, peeling, mechanical damage and edge breakdown. Identify and remove the cause of moisture, contamination or chemical attack before local repair. Prepare the substrate and apply compatible repair coats according to the approved coating specification. Maintain batch, mixing, curing and environmental records where required by the vessel coating plan. Pay particular attention to welds, edges, drains and high-abrasion zones. Refer to the manufacturer documentation for the exact figure for surface preparation, dry-film thickness, curing and overcoating requirements.
Spare Parts: Keep compatible primer, intermediate and topcoat materials required by the vessel coating scheme together with approved thinners, repair materials and application consumables. Respect shelf life and storage conditions and do not substitute a different coating chemistry without compatibility checks.
SigmaShield PSPC 880 IMO PSPC System unverified
Product Line
SigmaShield PSPC 880
Coating Type
tank
Imo pspc compliant
ja
Application Method
airless spray
Dft (µm)
320
Voc (g/l)
180
🎯 Application Area
Application: It is used for marine corrosion and surface protection on merchant ships, passenger vessels, offshore units or other vessel types where this equipment category is fitted.
Common Failures & Inspection Points
  • Blistering caused by moisture, osmotic contamination or poor surface preparation, resulting in raised bubbles and localized coating loss
  • Delamination caused by inadequate surface preparation, contamination or incompatible overcoating, resulting in peeling or loss of adhesion
  • Underfilm corrosion caused by coating damage, holidays or poor edge coverage, resulting in rust staining and progressive coating breakdown
  • Cracking or embrittlement caused by excessive film build, aging or substrate movement, resulting in visible cracks and loss of barrier protection
  • Abrasion, impact or chemical attack caused by service exposure, resulting in worn areas, discoloration or exposed substrate
Service: Inspect coated surfaces for blistering, rusting, cracking, peeling, mechanical damage and edge breakdown. Identify and remove the cause of moisture, contamination or chemical attack before local repair. Prepare the substrate and apply compatible repair coats according to the approved coating specification. Maintain batch, mixing, curing and environmental records where required by the vessel coating plan. Pay particular attention to welds, edges, drains and high-abrasion zones. Refer to the manufacturer documentation for the exact figure for surface preparation, dry-film thickness, curing and overcoating requirements.
Spare Parts: Keep compatible primer, intermediate and topcoat materials required by the vessel coating scheme together with approved thinners, repair materials and application consumables. Respect shelf life and storage conditions and do not substitute a different coating chemistry without compatibility checks.

Kansai Paint Marine

3
Kansai BT Coat 900 unverified
Product Line
BT Coat
Coating Type
tank
Application Method
airless spray
Dft (µm)
300
Voc (g/l)
155
Overcoating Interval (h)
12
🎯 Application Area
Application: Corrosion, fouling, chemical, slip or fire protection of hull, tanks, decks and machinery spaces according to the listed coating system.
Common Failures & Inspection Points
  • Blistering caused by moisture, osmotic contamination or poor surface preparation, resulting in raised bubbles and localized coating loss
  • Delamination caused by inadequate surface preparation, contamination or incompatible overcoating, resulting in peeling or loss of adhesion
  • Underfilm corrosion caused by coating damage, holidays or poor edge coverage, resulting in rust staining and progressive coating breakdown
  • Cracking or embrittlement caused by excessive film build, aging or substrate movement, resulting in visible cracks and loss of barrier protection
  • Abrasion, impact or chemical attack caused by service exposure, resulting in worn areas, discoloration or exposed substrate
Service: Inspect coated surfaces for blistering, rusting, cracking, peeling, mechanical damage and edge breakdown. Identify and remove the cause of moisture, contamination or chemical attack before local repair. Prepare the substrate and apply compatible repair coats according to the approved coating specification. Maintain batch, mixing, curing and environmental records where required by the vessel coating plan. Pay particular attention to welds, edges, drains and high-abrasion zones. Refer to the manufacturer documentation for the exact figure for surface preparation, dry-film thickness, curing and overcoating requirements.
Spare Parts: Keep compatible primer, intermediate and topcoat materials required by the vessel coating scheme together with approved thinners, repair materials and application consumables. Coating shelf life and storage conditions must be respected. Do not substitute a different coating chemistry without compatibility and approval checks.
Kansai BT Premium 1200 unverified
Product Line
BT Premium
Coating Type
tank
Application Method
airless spray
Dft (µm)
350
Voc (g/l)
140
Overcoating Interval (h)
12
🎯 Application Area
Application: It is used for marine corrosion and surface protection on merchant ships, passenger vessels, offshore units or other vessel types where this equipment category is fitted.
Common Failures & Inspection Points
  • Blistering caused by moisture, osmotic contamination or poor surface preparation, resulting in raised bubbles and localized coating loss
  • Delamination caused by inadequate surface preparation, contamination or incompatible overcoating, resulting in peeling or loss of adhesion
  • Underfilm corrosion caused by coating damage, holidays or poor edge coverage, resulting in rust staining and progressive coating breakdown
  • Cracking or embrittlement caused by excessive film build, aging or substrate movement, resulting in visible cracks and loss of barrier protection
  • Abrasion, impact or chemical attack caused by service exposure, resulting in worn areas, discoloration or exposed substrate
Service: Inspect coated surfaces for blistering, rusting, cracking, peeling, mechanical damage and edge breakdown. Identify and remove the cause of moisture, contamination or chemical attack before local repair. Prepare the substrate and apply compatible repair coats according to the approved coating specification. Maintain batch, mixing, curing and environmental records where required by the vessel coating plan. Pay particular attention to welds, edges, drains and high-abrasion zones. Refer to the manufacturer documentation for the exact figure for surface preparation, dry-film thickness, curing and overcoating requirements.
Spare Parts: Keep compatible primer, intermediate and topcoat materials required by the vessel coating scheme together with approved thinners, repair materials and application consumables. Respect shelf life and storage conditions and do not substitute a different coating chemistry without compatibility checks.
Kansai PSPC BT IMO PSPC System unverified
Product Line
Kansai PSPC BT
Coating Type
tank
Imo pspc compliant
ja
Application Method
airless spray
Dft (µm)
320
Voc (g/l)
180
🎯 Application Area
Application: Used throughout ships and offshore units for corrosion protection, fouling control, deck safety and protection of tanks or exposed structures.
Common Failures & Inspection Points
  • Poor surface preparation can cause early loss of adhesion, seen as peeling, blistering or underfilm corrosion
  • Contamination or moisture during application can create coating defects, noticed as pinholes, craters, soft film or poor cure
  • Mechanical damage can expose the substrate, seen as scratches, impact damage or localized rusting
  • Incompatible overcoating or incorrect application sequence can cause wrinkling or delamination, found during inspection
  • Ageing and environmental attack can reduce film integrity, seen as chalking, erosion, cracking or fouling depending on service
Service: Inspect coating continuity, adhesion-related defects, corrosion breakthrough and damage at welds, edges and high-wear areas. Repairs should use the approved coating scheme and surface-preparation procedure. Film thickness, curing times and environmental application limits not supplied in the source entry must be taken from the coating manufacturer’s documentation.
Spare Parts: Maintain compatible repair coating, approved thinner or cleaner where permitted, and the vessel’s standard surface-preparation and application consumables.

Tianjin Dowill Paints Technology

3
DWEPOMARINE AC-660
Model Number
TAK00002G8
🎯 Application Area
Application data not yet recorded.
DWEPOMARINE AR-600
Model Number
TAK00002G9
🎯 Application Area
Application data not yet recorded.
DWEPOMARINE AC-600
Model Number
TAK00002G7
🎯 Application Area
Application data not yet recorded.

Xiamen SunRui Ship Coating

3
725-H53-205
Model Number
TAK000024S
🎯 Application Area
Application data not yet recorded.
725-H53-201
Model Number
TAK000024R
🎯 Application Area
Application data not yet recorded.
725-H06-51
Model Number
TAK000024K
🎯 Application Area
Application data not yet recorded.

Yung Chi Paint & Varnish Mfg

3
RAINBOPRIME 806
Model Number
TAK00001F0
🎯 Application Area
Application data not yet recorded.
RAINBOPRIME 805
Model Number
TAK00001EZ
🎯 Application Area
Application data not yet recorded.
RAINBOPRIME 801
Model Number
TAK00000TE
🎯 Application Area
Application data not yet recorded.

Carboline Norge

2
Carbomastic 652
Model Number
TAK00002AT
🎯 Application Area
Application data not yet recorded.
Carbomastic® 18 FC
Model Number
TAK00000VE
🎯 Application Area
Application data not yet recorded.

KANSAI PAINT MARINE

2
EPOMARINE EX21 and EPOMARINE EX21QD
Model Number
TAK000000F
🎯 Application Area
Application data not yet recorded.
SD ZINC 100QD + EPOMARINE EX21 and SD ZINC 100QD + EPOMARINE EX21QD
Model Number
TAK000000G
🎯 Application Area
Application data not yet recorded.

KCC Marine Coatings

2
KCC EPIKOTE 1200 BT unverified
Product Line
EPIKOTE
Coating Type
tank
Application Method
airless spray
Dft (µm)
350
Voc (g/l)
145
Overcoating Interval (h)
12
🎯 Application Area
Application: Corrosion, fouling, chemical, slip or fire protection of hull, tanks, decks and machinery spaces according to the listed coating system.
Common Failures & Inspection Points
  • Blistering caused by moisture, osmotic contamination or poor surface preparation, resulting in raised bubbles and localized coating loss
  • Delamination caused by inadequate surface preparation, contamination or incompatible overcoating, resulting in peeling or loss of adhesion
  • Underfilm corrosion caused by coating damage, holidays or poor edge coverage, resulting in rust staining and progressive coating breakdown
  • Cracking or embrittlement caused by excessive film build, aging or substrate movement, resulting in visible cracks and loss of barrier protection
  • Abrasion, impact or chemical attack caused by service exposure, resulting in worn areas, discoloration or exposed substrate
Service: Inspect coated surfaces for blistering, rusting, cracking, peeling, mechanical damage and edge breakdown. Identify and remove the cause of moisture, contamination or chemical attack before local repair. Prepare the substrate and apply compatible repair coats according to the approved coating specification. Maintain batch, mixing, curing and environmental records where required by the vessel coating plan. Pay particular attention to welds, edges, drains and high-abrasion zones. Refer to the manufacturer documentation for the exact figure for surface preparation, dry-film thickness, curing and overcoating requirements.
Spare Parts: Keep compatible primer, intermediate and topcoat materials required by the vessel coating scheme together with approved thinners, repair materials and application consumables. Coating shelf life and storage conditions must be respected. Do not substitute a different coating chemistry without compatibility and approval checks.
KCC PSPC System IMO PSPC System unverified
Product Line
KCC PSPC System
Coating Type
tank
Imo pspc compliant
ja
Application Method
airless spray
Dft (µm)
320
Voc (g/l)
180
🎯 Application Area
Application: Used throughout ships and offshore units for corrosion protection, fouling control, deck safety and protection of tanks or exposed structures.
Common Failures & Inspection Points
  • Poor surface preparation can cause early loss of adhesion, seen as peeling, blistering or underfilm corrosion
  • Contamination or moisture during application can create coating defects, noticed as pinholes, craters, soft film or poor cure
  • Mechanical damage can expose the substrate, seen as scratches, impact damage or localized rusting
  • Incompatible overcoating or incorrect application sequence can cause wrinkling or delamination, found during inspection
  • Ageing and environmental attack can reduce film integrity, seen as chalking, erosion, cracking or fouling depending on service
Service: Inspect coating continuity, adhesion-related defects, corrosion breakthrough and damage at welds, edges and high-wear areas. Repairs should use the approved coating scheme and surface-preparation procedure. Film thickness, curing times and environmental application limits not supplied in the source entry must be taken from the coating manufacturer’s documentation.
Spare Parts: Maintain compatible repair coating, approved thinner or cleaner where permitted, and the vessel’s standard surface-preparation and application consumables.

Berger Paints Singapore

1
EPIMASTIC 3000HS
Model Number
TAK00001HA
🎯 Application Area
Application data not yet recorded.

Chugoku Paints

1
BANNOH 1500 and BANNOH 1500 QD
Model Number
TAK00000T4
🎯 Application Area
Application data not yet recorded.

COSCO Kansai Paint & Chemicals (Zhuhai)

1
EPOMARINE SUPER EX-21
Model Number
TAK00001KM
🎯 Application Area
Application data not yet recorded.

COSCO KANSAI PAINT (SHANGHAI)

1
EPOMARINE SUPER EX-21
Model Number
TAK00000B5
🎯 Application Area
Application data not yet recorded.

Kangnam Jevisco

1
KCI Edmarine K21S
Model Number
TAK00000AC
🎯 Application Area
Application data not yet recorded.

KCC(Kunshan)

1
KOREPOX EH2350
Model Number
TAK000000J
🎯 Application Area
Application data not yet recorded.

MEGA Coatings (Nantong)

1
Mega UEP 500 (Universal Epoxy Primer)
Model Number
TAK00002JZ
🎯 Application Area
Application data not yet recorded.

P&C TECH

1
ECO TK MARINE H
Model Number
TAK00001ZF
🎯 Application Area
Application data not yet recorded.

SUZHOU JIREN HIGH-TECH MATERIALS

1
JC9411 Epoxy Ballast Tank Paint
Model Number
TAK0000217
🎯 Application Area
Application data not yet recorded.

T&H Novel Materials

1
XH4223
Model Number
TAK00002E4
🎯 Application Area
Application data not yet recorded.

The Transocean Marine Paint Association

1
Transpoxy Barrier 218
Model Number
TAK00000GA
🎯 Application Area
Application data not yet recorded.

TMP Tenax Marine Paints Vertriebs

1
Tenaxon T 570 H
Model Number
TAK00002C6
🎯 Application Area
Application data not yet recorded.